STR36 Designer Woodburning Fireplace
For use in U.S./CanadaUnderwriter's Laboratories Report No. MH7603
DO NOT DISCARD THIS MANUAL: Retain for future use.7412961 5/12 Rev. 23
Homeowner's Installation and Operating Manual
2
STR36 Designer Woodburning Fireplaces
7412961
Safety InformationPLeASe ReAD THIS MANUAL beFORe INSTALLINg AND USINg FIRePLACe.IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
DescriptionThe STR36 fireplaces are multi-side solid fuel, woodburn-ing fireplaces. These are radiant models only and include a preinstalled outside air kit.
PrecautionsMHSC and component parts have been highly tested and will operate safely when installed in accordance with instructions provided in this manual. Carefully read and understand all instructions before beginning installation.If you notice any damage to fireplace or component parts, immediately report damage to your MHSC dealer.Only use MHSC components or the warranty will be voided and a fire hazard may be created.MHSC warranty will be voided by and MHSC disclaims any responsibility for the following actions:
• Installation by any other than a qualified install-er, preferably NFI or WeTT (Canada) certified.
• Installation of any damaged fireplace or chim-ney component;
• Modification of fireplace, chimney assembly or any component parts thereof; (except for chase flashings as detailed in the Chimney Top instal-lation instructions).
• Installation other than as instructed by MHSC; or
• Installation and/or use of any component part not manufactured or approved by MHSC in combination or assembly with a MHSC fireplace system, notwithstanding any independent test-ing laboratory or other third party approval of such component parts or accessory.
Any such action may possibly cause a fire hazard.Consult local building codes to ensure that you are in compliance before installing the fireplace.Fireplaces must be vented to the out-of-doors.Do not obstruct or modify air inlets/outlets in any manner.
Do not install combustible materials on any of the black fireplace surround.burn only solid wood fuel or gas logs.Do not install a solid fuel burning insert or other products not specified for use with this fireplace.
Proposition 65 Warning: Fuels used in gas, wood-burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6
WARNINg: Check with your electronics manufacturer before installing a television or other electronic de-vice above this fireplace.
DraftsThe fireplace should not be located in areas that create drafts (ie: frequently opened doors and central heating air inlets/outlets) that hamper the normal flow of air into the fire.
gas LogsIf you plan to install a gas log, the gas line should be installed before framing the fireplace. The gas line must be installed by a certified gas line installer.
STR36Listed
UL 127 / ULC-S610Standard for Factory built Fireplaces
Safety Information . . . . . . . . . . . . . . . . . . 2Specifications and Framing . . . . . . . . . . 3Parts Identification . . . . . . . . . . . . . . . . . 4Chimney Requirements . . . . . . . . . . . . . 6Planning Information . . . . . . . . . . . . . . . . 7Installation . . . . . . . . . . . . . . . . . . . . . . . 8Replacement Parts . . . . . . . . . . . . . . . . 20Accessories . . . . . . . . . . . . . . . . . . . . . 22
Table of Contents
3
STR36 Designer Woodburning Fireplaces
7412961
STR36 Fireplace Dimensions
Fig. 1 STR36 specifications and framing.
12”(305 mm)
9 ”(241 mm)
49 ”(1267 mm)36"
(914 mm)
Gas Line Access
FP702ASTR SPECS9/24/98added note 9/21/993/09
Outside Air
14 ”(372 mm)
20” (508 mm)
12" (305 mm)
11” (279 mm ) Dia.
CL24" Total Unit Width
Framing WidthWill be 24" Minus2 x (Drywall Thickness)
18 ”(464 mm)
STR33 STR36 STR42A 33" 36" 42" 838mm 914mm 1067mmB 37" 40" 46" 940mm 1016mm 1168mmC 18 " 20" 23" 470mm 508mm 584mmD 49 " 49 " 53 "1267mm 1267mm 1368mm
E 52 " 52 " 56 "1340mm 1340mm 1442mm
F 11" 11" 13 "279mm 279mm 343mm
G 8" 8" 11" 203mm 203mm 279mmJ 26 " 29 " 35 " 680mm 741mm 894mm
8” (203 mm ) Dia.
12”(305 mm)
52 ”(1340 mm)
36” (914 mm)
40” (1016 mm)
29 ” (741 mm)
7 ”(191 mm)
21”(533 mm)
37”(940 mm)
7 ”(191 mm)
4
STR36 Designer Woodburning Fireplaces
7412961
FP701a
STR36 Woodburning Fireplace
Fig. 3 STR36 Parts Identification.
A B
FP1545hearth dimensions1/05
Front/back Width Side Width A b STR36 29" 17Z\," (737 mm) (435 mm)
FP1545
Fig. 3a Hearth dimensions.
FP701aSTR Parts ID
Gas LineAccess
Outer Dome
Outside Air Access
Ledge Brackets
Header Standoffs
Flue Damper Control(Inside)
Flue CollarOuter Collar
Gas Line Knock-out(Both Sides)
Brick liner on Sides and Hearth
Air Inlet
Hearth
Wood Grate
Firebox
Metal Safety Strips,shown not in place(1, 2, or 3 Pieces)
Outside Air Control
5
STR36 Designer Woodburning Fireplaces
7412961
Chase InstallationInsulation methods shown are optional for cold climate, not a requirement for unit operation.
FP704
Fig. 4 Fireplace and chase parts identification.
FP704STR (from FP528)7/28/98
Termination Cap
Storm Collar
Pan Flashing
Draftstop
Finish Wall
Batt Insulation(cut out around firestop)
Firestop
Ceiling Level
Outer Dome
Refer to Figures 21 and 26 for clearance information.
Ledge Brackets
Nailing Flange
Gas Access(both sides)
Outside Air Cover Plate
Surround
Screen
Grate
Firebox
Outside Air Control
6
STR36 Designer Woodburning Fireplaces
7412961
Chimney Requirements - Offset Installations
0 0 0 0 0 3" 11" 1 0 0 0 0 8Z\₄" 20" 0 1 0 0 0 11Z\₄" 25Z\₄" 2 0 0 0 0 13Z\₂" 29Z\₄" 1 1 0 0 0 16Z\₂" 34Z\₄" 0 0 1 0 0 20Z\₄" 40³\₄" 2 1 0 0 0 21³\₄" 43Z\₂" 0 0 0 1 0 26Z\₄" 51Z\₄" 0 1 1 0 0 28Z\₂" 55Z\₄" 1 0 0 1 0 31Z\₂" 60Z\₄” 0 1 0 1 0 34Z\₂" 65Z\₂" 0 0 2 0 0 37Z\₂" 70³\₄" 1 1 0 1 1 41Z\₂" 77³\₄" 0 0 1 1 1 45" 83³\₄" 0 1 2 0 1 47Z\₄" 87Z\₂" 0 0 0 2 1 51" 94" 0 1 1 1 1 53Z\₄" 98" 0 0 3 0 1 56Z\₄" 103Z\₄" 0 1 0 2 1 59Z\₄" 108Z\₂" 0 0 2 1 1 62Z\₄" 113Z\₂" 0 1 3 0 1 64Z\₂" 117Z\₂" 0 0 1 2 1 68Z\₄" 124" 0 1 2 1 1 70Z\₂" 128" 0 0 0 3 1 74Z\₄" 134Z\₂" 0 1 1 2 2 78" 140³\₄" 0 0 3 1 2 81" 146" 0 1 0 3 2 84" 151Z\₄" 0 0 2 2 2 87" 156Z\₂" 0 1 3 1 2 89Z\₄" 160Z\₄" 0 0 1 3 2 93" 166³\₄" 0 1 2 2 2 95Z\₄" 170³\₄" 0 0 0 4 2 99Z\₄" 177³\₄" 0 1 1 3 2 101Z\₄" 181³\₄" 0 0 3 2 2 104Z\₄" 186Z\₄" 0 1 0 4 2 107Z\₄" 191Z\₂" 0 0 2 3 2 110Z\₄" 196³\₄" 0 1 3 2 3 114" 203Z\₄" 0 0 1 4 3 117³\₄" 209³\₄" 0 1 2 3 3 120" 213Z\₂" 0 0 0 5 3 123³\₄" 220"
30° elbow Offsets
1' 1¹⁄₂' 3' 4' Chim
ney
Supp
ort
Offset Rise
Notes: G + H cannot exceed 20 feet. Air Space Clearances: SK8 (2-wall) = 1Z\₂"
Illustration KeyThe following safety rules apply to offset installations (letters correspond with illustration above):
A. Height of the chimney is measured from the hearth to the chimney exit. STR36Maximum: 90'0" Minimum: Without Elbows 15'6" With 2 Elbows* 17'6" With 4 Elbows* 21' 0"
b. Do not use more than 4 elbows per chimney.
Attach the straps of the return (top) elbow to a structural framing member.
The offset (first) elbow of any pair does not have straps.
FP720
C. The chimney cannot be more than 30° (45° in Canada) from the vertical plane in any installation*.
D. The maximum length of the angled run of the total chimney system is 20 feet. (G plus H cannot exceed 20 feet.)
e. A chimney support (Models TCS8A) is required every 6 feet of angled run of chimney. Chimney supports are required for every 30 feet and 60 feet of vertical chimney height above the hearth.
Determine the offset distance of your chimney arrangement from the centerline of the fireplace to the centerline of the chimney where it is to pass through the first ceiling.
NOTe: This offset distance may not be your full offset distance. See Examples 2 and 3.
IWF282MBUF5/26/96
OFFSET
RISE
FP282
* In Canada, two (2) SK845 are allowed.
Fig. 5 Chimney system requirements.
DRISE
B G
H
B
OFFSET
C
E6 FT.
G
H
A
HEARTHFLOOR
CHIMNEYSECTION
CHIMNEY FLUE EXIT
ELBOW
FP720
STR/CVR6/4/98
30˚ OFFSETELBOW
30˚ OFFSETELBOW
30˚ RETURNELBOW
30˚ RETURNELBOW
SKCS8 SUPPORT
Example 1 Example 2 Example 3
7
STR36 Designer Woodburning Fireplaces
7412961
Planning InformationPreplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run.
NOTe: The STR36 model uses MHSC SK8 (2-wall) chimney systems.
Mounting the FireplaceA fireplace may only be mounted on the following sur-faces:1. A flat combustible surface.2. A raised wooden platform.3. A concrete block or other solid object placed beneath
each of the four (4) corners of the fireplace.The fireplace must be spaced 1/2" (13 mm) from a combustible back wall and 1/2" (13 mm) from a com-bustible side wall or support. (Page 14, Fig. 20)
Planning the Chimney RunDetermine how the chimney will be run, length of run and chimney components required to complete the job. (Fig. 6) Never install a chimney below minimum heights.
The Ten Foot RuleMajor U.S. building codes specify a minimum chimney height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed the “Ten Foot Rule,” especially when installing a termination on a high pitch roof. (Fig. 7)The key points of the "Ten Foot Rule" are:1. If the horizontal distance from the chimney to the
peak of the roof is 10' (3 m) or less, the top of the chimney must be at least 2' (610 mm) above the peak of the roof, but never less than 3' (914 mm) in height above the highest point where it passes through the roof.
2. If a horizontal distance from the chimney to the peak of the roof is more than 10' (3 m), a chimney height reference point is established on the surface of the roof a distance of 10' (3 m) from the chimney in a horizontal plane. The top of the chimney must be at least 2' (610 mm) above the reference point, but never less than 3' (914 mm) in height above the high-est point where it passes through the roof.
In planning a chimney system, it is important to know:1. The height of a chimney is measured from the
hearth to the exit point on the termination.2. A chimney cannot be offset more than 30° from a
vertical plane.3. A chimney may run straight up or it may be neces-
sary to offset it to avoid obstructions.4. The maximum length of an angled run (total chimney
system) is 20' (6 m). 5. No more than 2 offsets (4 total 30° elbows in U.S./or
2 total 45° elbows in Canada) per fireplace may be used.
6. A guy wire stabilizer is required for chimneys extend-ing more than 6' (1.8 m) above a roof line.
Fig. 6 Installed lengths of chimney sections.FP705
L1
L1
LTMODEL SK &
2 WALL CHIMNEYTOTAL
LENGTH(LT)
INSTALLEDLENGTH
(L1)
SK81SK818SK83SK84
"
"
"
"
"
"
"
"
FP705STR/CVR-CHIM SECT. INSTALLED LENGTH5/28/98
AC246
Fig. 7 Ten Foot Rule illustration.
2' Min.
2' Min.
3'Min.
0 To 10'
3'Min.
0 To 10'
AC246
4/1/96
ReferencePoint
8
STR36 Designer Woodburning Fireplaces
7412961
Insulating Fireplace enclosure for Cold Climates
If you live in a cold climate, it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.Insulate base of fireplace with a non-combustible insulation rated for a minimum of 300°F. Insulating is very important for outside wall installations over a concrete slab. If fireplace is installed on a platform, insulation should be placed on top of the platform before fireplace is set. (Fig. 9)When a fireplace is installed in a chase or on a outside wall, enclosure should be treated like any outside wall in a home. Insulation should be installed on the inside wall as well as the outside wall(s). In a chase, it is also a good idea to install a firestop at the first ceiling level above the fireplace and enclose the chase with sheeting material. Insulation may then be installed above sheeting material to assure the space around the fireplace is totally protected. (Fig. 4) When installing the chimney, DO NOT caulk be-tween outer pipe and firestop. It is vital that some air be allowed to flow through this very thin gap.CAUTION: WHEN INSTALLING A FIREPLACE IN AN INSULATED ENCLOSURE, BE SURE ALL REQUIRED AIR SPACES ARE MAINTAINED. (Page 14, Fig. 20)
InstallationChimney SupportsThe chimney system is supported by the fireplace for vertical chimney heights less than 20' (6 m) above the hearth. Chimney supports are required if the vertical height exceeds 20' (6 m). Locate chimney supports at ceiling holes or other structural framing at 20' (6 m) heights. Spacing between chimney supports must not exceed 20' (6 m). Use Chimney Support Model SKCS8 for SK8 chimney. (NOTe: the chimney support can not be mounted directly to the fireplace.) Support provided by elbow straps fulfills the support require-ment only if they are spaced as previously described. (A chimney support is 2Z\₂" (64 mm) long when installed.)Angled chimney runs require a support every 6' (1.8 m) in addition to the elbow straps. Chimney supports are used for this function. (Fig. 9)
Chase InstallationA chase is a vertical box-like structure which encloses the fireplace and/or chimney. Chases are typically built on the outside of the house with fireplace opening cut into the outer wall of a room. (Page 5, Fig. 4)If you need help in determining fireplace location or how the chimney system should be run, contact your MHSC dealer for assistance.
FP284
Fig. 8 Chimney support installationIWF284MBUF5/25/96
Chimney Sup-port Strap
SKCS8
9
STR36 Designer Woodburning Fireplaces
7412961
FramingFraming can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace.Frame fireplace with 2 x 4 lumber or heavier materi-als. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications. Headers and support studs must be turned on end as illustrated on Page 5, Figure 4.NOTe: Framing should be positioned to accommodate wall covering and fireplace facing material. Maintain 1/2" (13 mm) air space between the outer dome and any combustible framing materials that may be sup-ported by the ledge brackets. Refer to Figures 20 and 26 for details.
FP706
Fig. 9 Insulating between platform and fireplace.
FP706STR/CVR6/1/98
Hard, Flat Surface
Insulation
Plateform
Chimney Set-upSince you have already preplanned the chimney run, you should know exactly how the installation is to be accomplished — how much pipe is required, the number of elbows, if any, and type of termination to be used.CAUTION: REPORT TO YOUR DEALERS ANY PARTS DAMAGED IN SHIPMENT, SPECIFICALLY CHECK THE END CONNECTION OF CHIMNEY SEC-TIONS AND ELBOWS.NOTe: The STR36 model uses MHSC SK8 (2-wall) chimney systems.
Straight-Up Chimney InstallationTo locate the centerline of the flue put the fireplace in final position and place a plumb bob from the ceiling to the center of the fireplace flue collar. Mark this spot on the ceiling. Draw a line through that mark to either side of the firebox and indicate dimension X to locate the side wall framing. (Fig. 10) Be sure to observe clear-ance requirements for side and parallel combustible walls as noted in Page 16, Figure 23.
Offset InstallationIn order to clear an obstruction, it may be necessary to offset chimney from vertical. This is accomplished by using MHSC elbows. Use the 30° Offset Elbow table on Page 6 to determine proper offset and parts required.Each offset requires two (2) elbows. The second elbow is equipped with support straps. It is very important to install the second elbow in each offset as close to the ceiling or support as possible so that the elbow straps can be secured to framing members to help support the weight of the chimney.Determine offset distance of your chimney arrangement from centerline of fireplace to centerline of chimney where it is to pass through ceiling.Locate center point of the chimney on ceiling as though a straight up chimney arrangement is to be used. Measure your offset dimension from the chimney center point on the ceiling.
10
STR36 Designer Woodburning Fireplaces
7412961
Ceiling Chimney Hole/Possible Obstructions
The size of the hole in ceiling will vary with the angle at which the chimney passes through ceiling. Drive a nail up through ceiling at marked chimney cen-ter point. Go to floor above and see where hole will be cut. Check to see where existing ceiling joists and other possible obstructions are located...i.e. wiring, plumbing etc... If necessary, re-position chimney and/or fireplace to avoid obstructions.
Cutting the HoleCover fireplace collar opening and cut proper sized chimney hole in chimney. The SK8 pipe allows you to run pipe through a typical 16” on center joist without cutting joists.
Framing the Ceiling HoleFrame the ceiling chimney hole as shown in Figure 12. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level.The following table gives firestop spacer model num-bers:
FP707STR/CVRLOCATE CENTER LINE6/1/98
STR 33: 19" (483mm)STR36 / CVR36: 20 / " 521mm)STR42 / CVR42: 23 / " (597mm)
MODEL X =
20 ”(521 mm)
Fig. 10 Locate centerline of chimney with plumb line.
FP707
Actual Centerpoint
Chimney Centerline
Side of STR
Plumb Line
Plumb Bob
Imaginary Centerpoint
Fig. 12 Typical frame for ceiling chimney hole.FP551A
FP551ABR/BC9/23/98
14 " 14 "Existing Ceiling Joists
Chimney Hole
New Framing Members
Fig. 11 Ceiling chimney hole sizes necessary for installing firestop spacer.
Angle of Chimney at Ceiling Size of Chimney Vertical 30° 8" Flue SKFS2A SKFS6A "SK" Series 14Z\₂" x 14Z\₂" 14Z\₂" x 25Z\₂" (368 x 368 mm) (368 x 648 mm)
The inside dimension of the frame must be the same as the hole size selected from Figure 12 in order to provide the required air space (1Z/₂" (38 mm) with SK8 between the outside diameter of the chimney and the edges of the framed ceiling hole.
11
STR36 Designer Woodburning Fireplaces
7412961
Positioning, Safety Strips,Securing the Fireplace
Slide fireplace into position.Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1Z\₂" (38 mm), al-lowing the remainder to extend in front of firebox. Over-lap strips at least 1/2" (13 mm) to provide a positive joint. (Flat safety strips are packed with fireplace.) (Fig. 13) Safety strips are used to ensure that any combustible materials in front of the fireplace are protected even though a noncombustible hearth extension is required.If fireplace is to be elevated above the floor, a “Z” shaped metal safety strip must be fabricated and used to protect combustible surfaces in front of the fireplace. This “Z” shaped safety strip is not provided but must be fabricated of metal with each horizontal leg at least 1Z\₂" (38 mm) wide and equal in length to the metals strips provided with the fireplace.NOTe: Safety strips are not required over non-com-bustible floors where all supports at the base of the fireplace are noncombustible.Eight (8) nailing flanges are supplied with the fireplace (found on the fireplace hearth). To level the box and secure it firmly in place, remove the nailing flanges from the hearth and install at the sides of the fireplace as shown in Figure 14.
Outside Air KitAn outside air kit damper is installed in STR36 Fire-places. If desired, or if local codes mandate the use of an air kit, then an AK-MST is required to complete the installation (from air kit to the outdoors). If the outside air kit is to be used, the AK-MST Air Termination Kit MUST be installed beFORe the fireplace is enclosed. Refer to the AK-MST instructions for field installation. The outside air kit control is located in the lower left hand side of the fireplace behind the screen panel. (Fig. 15) To operate, simply lift up to close or push down to open .
WF708STR/CVR5/29/98
Metal Safety Strips(1, 2 or 3 pieces)
" (13mm)Min. Overlap"
(38mm)
"Z" Safety Strip
Fire-Place
Plat-Form Hearth Ext.
(not supplied)
FP708
Fig. 13 Safety strip installation.
FP709
Fig. 14 Fasten fireplace in position.FP7097/28/98STR/CVR
Model STR
Standoffs
Side-Nailing Flanges
Fig. 15 Outside air operation.
CLOSED
OPEN
WF 710OUTSIDE AIR LEVERWOOD FIREPLACES5/28/98
FP710
12
STR36 Designer Woodburning Fireplaces
7412961
Installing the Chimney SystemStart by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 16. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted.When installing elbows, only outer pipe will snap- lock. Middle pipes simply slide into position. Be sure to always attach straps on upper elbow to a structural framing member. (Fig. 17)Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer. Refer to Figure 18 for appropri-ate spacer orientation.
Installing the Firestop Spacer in the Ceiling Hole
A firestop spacer is used to keep pipe spaced properly and required for safety.Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTe: A firestop spacer is not required at the roof.Hole sizes listed in Figure 12 for angled firestop spac-ers provide minimum required air space to chimney pipe for ceiling thickness up to 8" (203 mm). When combined thickness of ceiling material, ceiling joists and flooring material exceeds 8" (203 mm), adjustments must be made in framing to assure that minimum air spaces to chimney are maintained.
Proper Firestop Spacer InstallationFigure 18 shows different installation procedures for both an area that is an attic and an area that is not an attic.If the area above the ceil-ing is not an attic, posi-tion the firestop spacer with the flange on the ceil-ing side and the angled portion extending up into the hole.If the area above the ceiling is an attic, position the firestop spacer with the flange on the top of the framed hole and the angled portion extending down into the hole.
FP711
Fig. 16 Install pipe, listening for the snap-lock to fasten.
UP
LanceHem
Pipe Rim
Pipe Rim
WF711STR/CVR5/28/98
Pipe Section
Fig. 17 Attach straps to a structural framing member.FP270/271 FP270/271
CR Series2/19/99 djt
elbow Strap Support Structure
Elbow Strap(must be tight)
Ceiling Hole Fram-ing
Angle Firestop
Chimney Support Strap(must be tight)
Angled Strap
FP593SR/C11/20/97
Attic Installation Ceiling Installation
Fig. 18 Installing firestop spacer.FP593
Nails (4)
Firestop Spacer
Joist
Joist
Firestop Spacer
Nails (4)NOTe: If the attic insulation shield is used, the firestop is not required in the attic installation.
13
STR36 Designer Woodburning Fireplaces
7412961
Consider this dimension when determining how many straight chimney sections are needed.NOTe: Chimney supports are generally used in long runs in a chase installation. A chimney support can-not be mounted directly to the fireplace.
Additional CeilingsIf you encounter additional ceilings, repeat same steps required for first ceiling installation. Refer to firestop illustration on Page 12, Figure 18.
Penetrating the RoofRun pipe to roofline. Since chimney system must be vented to the out-of-doors, you must use an approved termination.If a chase is used, refer to the installation manual pro-vided with the termination cap.
Locate Chimney Centerpoint on RoofUse same procedure detailed in locating centerpoint of the flue system.Drive a nail up through roof at the centerpoint. This will determine center point on outside of the roof.
Cut and Frame Roof HoleSize of roof hole varies with the type of chimney termi-nation installed. Refer to installation instructions pro-vided with the chimney termination to find correct size of roof hole.There must be an air space (1Z\₂" (38 mm) with SK8 between outermost portion of chimney sections and any adjacent combustible surfaces. (Fig. 20) (Combustible surfaces include burnable materials such as: ceiling members, joists, flooring, combustible insulation and roof structures.)WARNINg: DO NOT PACK ReQUIReD AIR SPACeS WITH INSULATION OR OTHeR MATeRIALS.Mark an outline of the roof hole around the center of the point nail. NOTe: Hole dimensions given in the chim-ney top installation instructions are horizontal dimen-sions; therefore, the hole size must be marked on the roof accordingly.Cover the opening of the installed chimney so debris cannot get into the system.Cut and frame the hole. It is good practice to use fram-ing lumber that is the same size as the rafters. Install the frame securely because the chimney top and flash-ing anchored to the frame must be able to withstand heavy winds.
Firestop spacers are not available for nor are they re-quired on vertical walls.DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer. If you seal this area, it may cause a fire hazard.
Canadian Requirements for Insulation Shield
In Canada, an attic insulation shield is required to prevent attic insulation from contacting the chimney section. NOTe: If the attic insulation shield is used, the firestop is not required in the attic installation. Fram-ing dimensions for the chimney hole should measure 14Z\₂" x 14Z\₂" (368 x 368 mm). (An attic shield MUST be installed on top of attic joists (above the floor level). (Fig. 19)NOTe: In the U.S., it is a good idea, although not al-ways required, to install an attic insulation shield where blown-in insulation is planned to be used in the attic. Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails. Attic shields are not required at the roof.
FP263
Fig. 19 Attic shield installlation (Canadian requirement).
IGF263MBUF5/9/96
Attic Insula-tion Shield
Nails(4 required)
Attic Joist
CeilingBase Flanges
Continue Installing Pipe to Complete RunContinue attaching pipe sections to complete system to next level always being careful that the pipe is firmly snapped locked in place before proceeding to next pipe section.
Chimney SupportsIf chimney supports are required, they are installed the same as elbows. Nail chimney support straps to ad-jacent structural framing, as shown on Figure 8, Page 8. Bend straps as necessary and make sure they are secure so they will support the weight of the chimney. A chimney support is 2Z\₂" (64 mm) long when installed.
14
STR36 Designer Woodburning Fireplaces
7412961
Install Remainder of Chimney SectionsSince you have already preplanned the height of your termination according to the Ten Foot Rule, continue to install pipe to the predetermined height.Check the chimney top installation instructions for details on how high above the roof top the chimney sec-tions (all pipes) should extend.
Installing Top Housing or TerminationFollow the installation instructions provided with the chimney termination you have selected.
Installing Chimney In a ChaseRefer to Page 5, Figure 4 for an illustration of a typical chase installation.CAUTION: Treatment of firestop spacers and construc-tion of chase may vary with type of building. These instructions are not a substitute for local building codes. You must check your local building codes to determine specific requirements for your city or state. NOTe: Other building materials may be required in addition to Firestop Spacers.
FinishingCAUTION: All joints between the finished wall and the fireplace surround (top/sides) must be sealed with non-combustible material to prevent cold air leakage into the room. Only noncombustible material may be applied to the facing of the fireplace surround. (Black painted area) (Fig. 20)
Finish WallFinish the wall with material of your choice. Do not install a combustible mantel shelf less than 12" (305 mm) above the front opening. Do not install a mantel face plate less than 6" (159 mm) from top of fireplace opening. (Fig. 21) If a combustible material is used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace opening to bottom of mantel shelf.NOTe: No side wall protection is required for fireplaces installed at 45° to two (2) side walls (corner installation).Adjacent combustible side walls that are within 16" (406 mm) of fireplace opening must be protected with a spe-cifically built wall shield as described in Figure 20 & 24.Often a decorative surround or vertical portion of the mantel is desired. If this is constructed of any combus-tible material, it must be within the safe zone indicated in Figure 24.
FP717
Fig. 20 Minimum clearances to combustibles.
Front View Side View
Standoff
Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas).
Air Space Clearances
Only noncombustiblematerial may be applied as facing to the black fireplace surround.
Wall Shield
Hearth Extension
0" Clearanceto Floor
Firestop
OUTERDOME
1/2" (13 mm) Air Spaceto Sides
1/2" (13mm) air space to sides
FP717STR/CVRAIR SPACES9/23/98
1 " (38 mm)
Maintain 1/2" (13 mm)
air spaceto sides
15
STR36 Designer Woodburning Fireplaces
7412961
MA81rev. 8/5/97
1 "Ref.
Combustible materials arepermitted within a shaded areashown in Figure 23, titledMinimum Wall Clearances.
*
* *
MA81
Fig. 22 Combustible mantel clearances.
Face Plate
*12" (305 mm) from top of fireplace opening.** 6" (159 mm) from top of fireplace opening. (Noncombustible material must separate the black face surround of the fireplace and any combustible mantel material)
FP721STR/CVR6/4/98
"
1/2"
*
12"(305mm)
Min.
12"(305mm)
Max.
1/2"
12"(305mm)
Min.
12"(305mm)
Max.
6“(159mm)
Min.
FP721
Fig. 21 Fireplace surround flush with finished wall.
Mantel Clearance - No Noncombustible Facing Material
Finished Wall
Standoff
2 x 4 Stud
Noncombustible Mate-rial
HeaderLedge Bracket
Fireplace Front
Fireplace Opening
* Minimum width from top of sur-round to bottom of screen rail
Combustible Mantel and Trim
Combustible Mantel and Trim
Standoff
Finished Wall
2 x 4 Stud
Noncombustible Mate-rial
HeaderLedge Bracket
Fireplace Front
Fireplace Opening
Noncombustible Facing Material
Finished Wall
2 x 4 Stud
Must be sealed with noncombustible materialFireplace
Front
Mantel Clearance - with Noncombustible Facing Material
16
STR36 Designer Woodburning Fireplaces
7412961
Side Wall ProtectionAll joints (top, bottom and sides) where wall or deco-rative facing material meets fireplace surround must be completely sealed with a noncombustible material. (Figs. 20 and 24) The special wall shield design described in Figure 20 is an alternate method of adding protection to side walls. Rt must =1.85 minimum.
examples of wall shield insulation:1. Manville - CERAFORM 126, K=.27, 1/2 inches thick2. MHSC - EH2416, K = .458, 1 inch thick required.
FP723
Fig. 23 Minimum firebox dimensions from combustible materials.
FP723STR/CVR Side Wall clearances6/21/98
A A
BB
CCC D
Perpendicular Side Wall
Parallel Side Wall
Minimum Dimensions to Side Walls(for on-site construction)
Model STR36 Parallel Side Wall A 44" to Movable Doors (1118 mm) Perpendicular B 16" Side Wall to Firebox Opening (406 mm) Air Space to Sides C 1/2" or Back of Unit (13 mm)
17
STR36 Designer Woodburning Fireplaces
7412961
WARNINg: HeARTH eXTeNSION MUST be IN-STALLeD IN ACCORDANCe WITH FIgUReS 24 AND 25.Alternate noncombustible materials may be used providing the (total) thermal resistance (Rt value) of the alternate material employed is greater than or equal to R = 1.09. Thermal resistance (R) or thermal conductivity (K), may be obtained from manufacturer of the material. Factors are related by the formula K = 1/R.T = given thicknessR = thermal resistance for a given thickness (T)K = thermal conductivityNoncombustible material with a lower R value may be used, provided thickness of material is sufficiently greater to maintain an equivalent (total) thermal resis-tance (Rt).
Hearth InstallationA hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 24 for mini-mum dimensions and mounting detail.Note: Hearth extension must not cover the air inlet opening of a fireplace.The hearth extension described in Figure 24 must be a durable noncombustible material with a minimum (total) Rt value of 1.09; refer to Figure 25 for examples. The overall height (above a combustible floor), depth and width must be as indicated, with the extension centered to the fireplace opening.The top of the insulation material must be covered with a noncombustible decorative covering or a piece of .018” minimum sheet metal, to protect hearth extension material. (Fig. 24)Secure the hearth extension to the floor to prevent shifting, using trim molding or other similar means at three (3) outer edges. Seal crack between the fireplace hearth and hearth extension with a noncombustible material. (Figs. 24 and 26)
Minimum Wall Clearances
WITHNoncombustibleSurround Facing
WITHOUTNoncombustibleSurround Facing
Minimum Hearth Extension Dimensions (for On-Site Construction)
GH
G
J
Seal cracks between thefireplaceand hearth extension with noncombustiblematerial
Safety stripsmust overlap
" minimum
May installnoncombustibledecorativecoveringOR .018" min.sheet metal Fireplace
Hearth
CombustibleFloor
1/2” Min. EH2416 orequal “R”value
4" MIN.
FP714STR/CVR6/4/98
FireboxOpening
A - Min. clearance to combustible perpendicular wall B - Min. clearance to combustible perpendicular wall when using noncombustible wall shield*
SideWall
SideWall
F**
C**
EED
4" BRICK (Example material)
Combustible material permitted within shaded area. * Noncombustible wall shield requires 1" MHSC EH2416 insulation (minimum R Value = 1.09) between decorative noncombustible rigid covering and combustible wall. Minimum height and width is 40" x 40". ** Dimension/degree of angle will vary depending on thickness of noncombustible surround facing.
4"
Shaded area starts 1/2" away from edge of unit
A B C D E F G H J K STR36 16" 12" 48° 41° 18" 14" 8" 16" 48" 24" (406 mm) (305 mm) (457 mm) (356 mm) (203 mm) (406 mm) (1219 mm) (610 mm)FP714Fig. 24 Combustible side wall protection and hearth extension dimensions.
18
STR36 Designer Woodburning Fireplaces
7412961
example of Determining Hearth extension equivalentsTo determine the thickness required for any new mate-rial:
COMMON MATERIALS AND FACTORS
MATERIAL K* R MINIMUM THICKNESS
EH2416Micor 300
Common Brick
0.458 5.0
1.09 0.50 in.** 0.10 5.46 in.**
R Value is for 1/2 inch. * Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material
FP533ADD Addendum 6/1/99 djt 8/4/99 changed .2 to .1 one inch to 1/2 inch djt
FP533ADFig. 25 Hearth extension material factors.
FP719STR/CVR finish wall treatments
5/28/98
Wall CoveringNoncombustibleDecorativeFacing
NoncombustibleDecorativeCovering
Seal all cracks between fireplace surround and wall materials with noncombustible material.
Seal crack between fireplace and hearth extensionwith noncombustible material.
2x4" Header - Do not notch at
standoffs.
2x4" Stud
Safety Strips -Must be overlapped
" minimum.
Hearth ExtensionInsulation
Side View
NOTE: / "air spacebetween
Outer Domeand
combustible materials
/ "
/ "Outer Dome
FP719
Fig. 26 Finish wall treatments and gap sealing.
NEW K of new material (per inch) thicknessrequired = X of listedthickness K of listed material (per inch) material
example for Common brickT (new) = 5.0 / 0.458 x 0.50 in. = 5.46 in. (new required thickness). Safety Strips Must be Over-
lapped 1/2" Min. Minimum Insulation Value R-0.94
1/4" Min. Thickness
Combustible Floor
Noncombustible Material 7Z\₂" Max. Thickness
Seal Cracks Between Fireplace and Hearth Extension with Noncombustible Material
Noncombustible Material
Lower Surround
Fireplace Hearth
FP1170
Fig. 27 Hearth extension dimensions.
2”(51 mm)
2”(51 mm)
Maximum14”
(356 mm)
Maximum10”
(254 mm)
A
A
Minimum33”
(838 mm)
Minimum36” (914 mm)
6”(152 mm)Minimum
Minimum .030 Thick Stain-less Steel Plate
Insulation with Minimum R Value of 2.75
Minimum .030 Thick Stainless Steel Plate
View ANOTe: If noncombustible material is not used between the stainless steel plate and fireplace opening, the steel must be attached to the front of the unit a minimum of four (4) places on each piece with sheet metal screws no longer than 1/2".NOTe: The size of the insulation and stainless steel plate must be within limits stated above and covers all combustible framing material.
Fig. 28 Recessed installation.
FP1608Hearth Extension
Hearth Extension
Noncombustible Material (if desired)
Insulation with Minimum R Value of 2.75
Recessed Installation - STR33/36 Only
19
STR36 Designer Woodburning Fireplaces
7412961
Installing Line for gas LogsMHSC are designed to accept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.)
Be sure to have the appliance installed in accordance with building codes. Gas connection may enter from either left or right side of the fireplace.Locate appropriate gas line in the outer casing of fire-place and remove insulation from gas line tube. (Fig. 29)From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" side of the fireplace. Using a flat bladed screw-driver or small chisel and hammer, carefully tap around the knockout until it loosens and falls out.Install 1/2" (13 mm) certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube.NOTe: gas pipe should not come in contact with any wood structures until it has reached a point at least 1" (25 mm) away from fireplace side. Note: Local codes may require removal of flue damper when installing any type of gas appliance in a fireplace.NOTe: When installing an ANSI Z21.11.2 ventless ap-pliance, the finishing material used for the mantel must be rated at 250°F or greater. BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr.Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating an automatic shutoff device and (2.) complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces (ANSI Z21.60) or CSA draft re-quirements for Gas-Fired Log Lighters for Woodburning Fireplaces (Draft No. 4, August 1993). Decorative gas appliance should be installed in accor-dance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 (latest edition).
1"
FP716CVR/STR Gas Access5/29/98
FP716
Fig. 29 Gas line access.
Fireplace Top View
Hole in Outer Casing
Gas Line Tube
Supply Line
Repack Insu-lation
Ceramic Knockout(Both Sides on STR)
Hole in Outer Cas-ing
CAUTION: WHeN USINg DeCORATIVe gAS APPLIANCe, FLUe DAMPeR MUST be SeT IN FULLY OPeN POSITION. IF YOU HAVe gLASS DOORS ON THe FIRePLACe, THeY MUST ALSO be FULLY OPeNeD.
WARNINg: DO NOT OPeRATe AN UNVeNTeD gAS LOg SeT IN THIS FIRe-PLACe WITH THe CHIMNeY ReMOVeD.
WARNINg: WHeN INSTALLINg AN UNVeNTeD gAS LOg SeT, THe MHSC MODeL CAbL OR CAbR 4" ADJUSTAbLe HOOD MUST be USeD.
Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.11.2, are to be installed in this fireplace.
If installing an unvented gas log set, refer to statement below:
20
STR36 Designer Woodburning Fireplaces
7412961
961
MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
5
1, 2, 34
6
7
a
b
cd
8
9
1011
961STR parts5/16/00 djt
12
STR36 Woodburning Fireplace Ref. Description STR36 1. Flue Damper RP102 2. Damper Handle 7548170 3. Damper Handle Push Nut 7512903 4. Screen Rod Assembly (two per fireplace) 3030126 5. Screen Assembly (four per fireplace) 7554338 6. Screen Pulls (four per fireplace) 5584139 7a. Firebrick - Hearth 3102103 7b. Firebrick - Side Ashlip (two per fireplace) 3102102 7c. Firebrick - Side (two per fireplace) 9079147 7d. Side Filler (four per fireplace) 3079148 8. Top Brick Retainers (four per fireplace) 3079130 9. Cable Clips (eight per fireplace) 7512135 10. Nailing Flange (eight per fireplace) 5069164 11. Basket Grate 2056100 12. O.S.A. Assy. 20003212
21
STR36 Designer Woodburning Fireplaces
7412961
Glass Door Bi-Fold door set Brushed Brass finish 36GDKBB - STR36 Black finish 36GDKBK - STR36 Polished Brass finish 36GDKDP - STR36 Pewter finish 36GDKS - STR36 Outside Air Termination Completes connection from air kit to out-of-doors AK-MST Hearth Extension Insulation Provides hearth extension floor protection EH2416 Basket Grate Holds firewood in firebox RBG36ST Hearth Patch Compound Patch cracks in hearth HPC-1
The following accessories for this appliance are available from your local MHSC distributor. Should you need addi-tional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361, Attn: Technical Services.
CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operat-ed only with MHSC approved components. If you use an unapproved component to make any modifications, you may create a possible fire hazard and will void the MHSC warranty. In addition, such action may void the coverage provided by the owner’s insurance.
Accessories
Model NumberDescriptionAccessory
Contact your MHSC distributor or dealer for finishing Marble and Mantels, available in a wide selection of styles.
22
STR36 Designer Woodburning Fireplaces
7412961
Chimney Components
Round Top Termination Round termination to be used with SK8 chimney RLTSK8 system. (Flashing not included.) Long Round Top Round top to be used with a chase installation RLTSK8L Termination utilizing SK8 chimneysystem. Knock-down Shroud - Black pyramid knock-down shroud used for PKDSBL Pyramid chase installations with any RLT round top termination. Gives appearance of a pyramid cap. Knock-down Shroud - Black square knock-down shroud used for SKDSBL Square chase installations with any RLT round top termination. Gives appearance of a square cap. Adaptor required Square Termination Top housing with simulated brick pattern. T20B (Red, Tan or Black) Proper adapter must be used. Includes flashing. Adapter Required adapters for T20B top housing. CF8CA (SK8) Housing Extensions Extends Square Termination on steep pitched roofs. 202036 Flashing Metal finishing required around Contemporary 8-6-12 with 8" flue: Termination to prevent rain leakage. 0-6/12 pitch 8-12-12 with 8" flue: 6/12-12/12 pitch Square Termination Top housing of simulated brick pattern T20B available in red, tan or white. Appropriate adapter required. Flashing included. SK8 Pipe used to build 8" SK8 flue systems. SK81 (1' Long) Chimney Sections SK818 (1Z\₂' Long) SK83 (3' Long) SK84 (4' Long) Chimney Elbows Elbow used to create an offset in a SK830 / 2 (SK8) chimney system. Only 30° elbows available. Packaged 2 per carton (offset and return). Firestop Required at each floor level of chimney SKFS2A — SK8 installation. (Plus attic on multi-story installation.) (8" straight flue) SKFS6A — SK8 (8" 30° inclined flue) Chimney Support Used to support chimney for each of: 20' vertical SKCS8 - SK8 height and 6' of angled chimney run. Attic Insulation Shield Used to prevent insulation from coming in contact AIS-SK - SK8 with the chimney system.
U.S.Model NumberDescriptionComponent
23
STR36 Designer Woodburning Fireplaces
7412961
Attic Insulation Shield Used to prevent insulation from coming in AIS-SK - SK8 contact with the chimney system. SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN (1Z\₂') SK8 roof. SK84CAN (4') SK8 45° Chimney Elbows Provides 45° offset and return. FOR CANADIAN SK845/2 INSTALLATIONS ONLY. For use with SK8 chimney only. (Maximum use of 2, or 1pair.)
CanadaModel NumberDescriptionComponent
LIMITeD WARRANTYFactory-build Fireplace and Components
(except blowers)
What is Covered and For How LongFive-Year Coverage: For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed the factory retail price in effect at the time of purchase.Ten-Year Coverage: From the sixth through the tenth year following the date this fireplace or accessory is first purchased for use, MHSC will make available to you, at our factory, a free replacement for any defective part in this fireplace or accessory.Twenty-Five-Year Availability of Replacement Parts: From the eleventh through the twenty-fifth year following the date this fireplace or accessory is first purchased for use, MHSC will make available at our factory replacement parts for this fireplace or accessory, which you may purchase for the list price current at the time your purchase order is received.
What is Not Covered• This limited warranty does not cover:• Transportation or shipping cost.• The cost of a service call to diagnose trouble.• Painted surfaces.• Damage or defect caused by improper installation, accident, misuse, abuse or alteration.• Poor ventilation of smoke or gases caused by air-conditioning and heating systems, exhaust fans, or pressure dif-
ferentials produced by wind.• Broken glass components.• Cracks in ceramic and castable parts that do not affect safe operation.• We do not warrant this fireplace to be in compliance with your local building code. Building codes vary greatly
throughout the country, and you should determine whether your local building code contains restrictions on the use of this fireplace before you purchase it.
• Blowers or fans, which are warranted separately.• Heat loss due to the passage of heat or air through or around the fireplace.Also, under our five year coverage, we do not pay the cost of removal and replacement of any portion of the structure in which the fireplace is situated, made necessary by the repair, removal or re-installation of the fireplace.And under our twenty-five year warranty of availability of replacement parts, we only promise to maintain a supply of replacement parts at our factory for you to purchase.
Limitations and exclusions1. No one has authority to add to or vary this limited warranty, or to create for MHSC any other obligations of liability
in connection with this fireplace and accessory.2. MHSC shall not be liable for incidental, consequential, special or contingent damages you might suffer as a result
of its breach of this written warranty or any implied warranty. Some states do not allow the exclusion of limitation of incidental or consequential damages, so the above limitations may not apply to you.
3. This warranty applies only to a fireplace sold and used in the United States.IF WARRANTY SeRVICe IS NeeDeD...1. Contact your supplier. Make sure you have your warranty, your sales receipt and the model/serial number of your
MHSC product.2. DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.