Home Inspection Report
1 Sample Dr., Your City, MD 22222
Inspection Date:Monday January 2, 2017
Prepared For:My Client My Client
Prepared By:Dan Block
(410)358-4603
Report Number:1
Inspector:Dan Block
1 Sample Dr., Your City, MD 22222 Page 2
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Receipt/InvoiceDan Block(410)358-4603
Property Address1 Sample Dr.Your City, MD 22222
Date: Jan 2, 2017 Inspection Number: 1
Inspected By: Dan Block Payment Method: Credit Card
Client: My Client My Client
Inspection FeeHome Inspection $450.00
Total $450.00
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 3
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Report SummaryItems Not Operating
None
Major ConcernsRoof area has exposed section. Recommend qualified roofing contractor to evaluate and repair as needed.
Potential Safety Hazards1.Height of service entry line is below 8 feet and should be at least 10 feet above deck and not within 3 feet of window. Recommend qualified licensed electrical contractor to evaluate and repair as needed.
2.Double tapped conductors at breaker. Pre-existing unused conductor needs to be capped off.Recommend qualified licensed electrical contractor to evaluate and repair as needed.
Deferred Cost ItemsNone
Improvement Items1.Upper deck appears to be used for cover over lower patio area. Several joists are fastened with deck screws and not with joist hangers to ledger board. Recommend qualified licensed contractor to evaluate and repair as needed. 2. Drain spout terminates directly at concrete slab.It should terminate 5 - 6 feet from structure. Recommend extension. 3. 2nd floor deck has small area that needs sealing. Vertical section of wood shows signs of rot. Recommend qualified licensed contractor to evaluate and repair as needed. 4.Hose bib needs to be secured and caulked. 5.No cut off switch at heatpump.Switch should be within sight. 6.Chimney shows signs of scaling and loose brick as well as in need of repointing. Area where roof meets chimney is exposed and may allow for water intrusion.Recommend qualified licensed roofer and masonry contractors to evaluate entire roof and repair as needed. 7.Main panel and breakers appear to be Square D, however some breakers are covered. Some data markings don't match to breakers. Recommend qualified licensed electrical contractor to evaluate and correct as needed. 8.Electrical supply to washer is from an extension cord behind wall. It is difficult to see access.Recommend qualified licensed electrical contractor to evaluate and install dedicated line and proper receptacle. 9.Open ground in bedroom. Recommend qualified licensed electrical contractor to evaluate and repair as needed.
Items To MonitorTypical cracks in concrete. Monitor and repair if cracks become larger or wider.
Several layers of roofing material and tar were on roof. No signs of water intrusion were observed. Buyer needs to monitor roof and ceiling conditions for any water penetrations.
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 4
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Report OverviewScope of Inspection
All components designated for inspection in the ASHI Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report. It is the goal of the inspection to put a home buyer in a better position to make a buying decision. Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind.Please refer to the pre-inspection contract for a full explanation of the scope of the inspection.
Main Entrance FacesEast
State of OccupancyOccupied
Weather ConditionsCloudy Rain
Recent RainYes
Ground CoverWet
Approximate Age97
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 5
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
GroundsService Walks
None Not Visible
Material X Concrete Flagstone Gravel Brick Other:
Condition X Satisfactory Marginal Poor Trip hazard Typical cracks Pitched towards homeSettling cracks Public sidewalk needs repair
Comments
Driveway/Parking
X None Not Visible
Material Concrete Asphalt Gravel/Dirt Brick Other:
Condition Satisfactory Marginal Poor Settling Cracks Typical cracks Pitched towards homeTrip hazard Fill cracks and seal
Comments Grass/ dirt area in back of structure appears to have been used for parking. Buyer needs to be aware that rain and snow conditions may lead to vehicle becoming stuck in mud. Some patio blocks around perimeter of parking area are loose.
Photos
Area in back of house that may have been used for parking & area of loose patio blocks.
Porch
X None Not Visible
Condition Satisfactory Marginal Poor Railing/Balusters recommended
Support Pier Concrete Wood Other:
Floor Satisfactory Marginal Poor Safety Hazard
Comments
Stoops/Steps
None
Material X Concrete Wood Other: Railing/Balusters recommended
Condition X Satisfactory Marginal Poor Safety Hazard Uneven risers Rotted/DamagedCracked Settled
Comments
Photos
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 6
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Grounds
Front stoop.
Patio
None
Material X Concrete Flagstone Kool-Deck Brick Other: Wooden Deck
Condition X Satisfactory Marginal Poor Settling cracks Trip hazardPitched towards home (see remarks) Drainage provided X Typical cracks
Comments Typical cracks in concrete. Monitor and repair if cracks become larger or wider.
Photos
Deck in rear of home. Typical cracks in concrete. Typical cracks in concrete.
Deck/Balcony
None Not Visible
Material X Wood Metal Composite Railing/Balusters recommended
Condition X Satisfactory Marginal Poor Wood in contact with soil
Finish X Treated Painted/Stained Other: Safety Hazard X Improper attachment to houseRailing loose Not Applicable
Comments Upper deck appears to used for cover over lower patio area.Several joists are fastened with deck screws and not with joist hangers to ledger board.Recommend qualified licensed contractor to evaluate and repair as needed. Drain spout terminates directly at concrete slab.It should terminate 5 - 6 feet from structure. 2nd fl deck has small area that needs sealing. Vertical section of wood shows signs of rot and may allow for water intrusion.Recommend qualified licensed contractor to evaluate and repair as needed.
Photos
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 7
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Grounds
Missing deck hangers. Missing deck hangers.
Drains directly at concrete slab. Area of wood at 2nd level that show signs of rot.
Deck/Patio/Porch Covers
X None
Condition Satisfactory Marginal Poor Posts/Supports need Repair Earth to wood contactMoisture/Insect damage
Recommend Metal Straps/Bolts/Nails/Flashing Improper attachment to house None
Comments
Fence/Wall
Not evaluated None
Type Brick Block X Wood Metal Chain Link Rusted Vinyl
Condition X Satisfactory Marginal Poor Typical cracks Loose Blocks/Caps
Gate N/A X Satisfactory Marginal Poor Planks missing/damaged Operable: X Yes No
Comments
Landscaping affecting foundation
X N/A
Negative Grade East West North South Satisfactory Recommend additional backfillRecommend window wells/covers Trim back trees/shrubberiesWood in contact with/improper clearance to soil
Comments
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 8
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
GroundsRetaining wall
X None
Material Brick Concrete Concrete block Other: Railroad ties Timbers
Condition Satisfactory Marginal Poor Safety Hazard Leaning/cracked/bowedDrainage holes recommended
Comments
Hose bibs
N/A
Condition X Satisfactory Marginal Poor No anti-siphon valve Recommend Anti-siphon valve
Operable Yes X No Not Tested Not On
Comments Hose bib needs to secured and needs caulking.
Photos
Hose bib at rear of home.
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 9
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
RoofGeneral
Visibility None All X Partial Limited By: StructureRoof inspection was limited to viewing from the ground due to rain.
Inspected From Roof Ladder at eaves X Ground With BinocularsRoof area has exposed section. Recommend qualified roofing contractor to evaluate and repair as needed.
Photos
Roof area exposed.
Style of Roof
Type X Gable Hip Mansard Shed Flat Other:
Pitch Low X Medium Steep Flat
Roof #1 Type: Built-up Layers: 1+ Layers Age: Unknown . Several layers of roofing material and tar were observed. No signs of water intrusion were observed. Buyer needs to monitor roof and ceiling conditions. Location:
Roof #2 X NoneType: Layers: Age: Location:
Roof #3 X NoneType: Layers: Age: Location:
Comments
Ventilation System
None X N/A
Type Soffit Ridge Gable Roof Turbine Powered Other:
Comments
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 10
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
RoofFlashing
Material X Not Visible Galv/Alum Asphalt Copper Foam Rubber Lead Other:
Condition X Not Visible Satisfactory Marginal Poor Rusted MissingSeparated from chimney/roof Recommend Sealing Other:
Comments All flashing were covered by tar.
Valleys
X N/A
Material Not Visible Galv/Alum Asphalt Lead Copper Other:
Condition Not Visible Satisfactory Marginal Poor Holes Rusted Recommend Sealing
Comments
Condition of Roof Coverings
Roof #1 X Satisfactory Marginal Poor Curling Cracking Ponding Burn SpotsBroken/Loose Tiles/Shingles Nail popping Granules missing Alligatoring BlisteringMissing Tabs/Shingles/Tiles Moss buildup Exposed felt CuppingIncomplete/Improper Nailing X Recommend roofer evaluate Evidence of Leakage
Roof #2 X N/A Satisfactory Marginal Poor Curling Cracking Ponding Burn SpotsBroken/Loose Tiles/Shingles Nail popping Granules missing Alligatoring BlisteringMissing Tabs/Shingles/Tiles Moss buildup Exposed felt CuppingIncomplete/Improper Nailing Recommend roofer evaluate Evidence of Leakage
Roof #3 X N/A Satisfactory Marginal Poor Curling Cracking Ponding Burn SpotsBroken/Loose Tiles/Shingles Nail popping Granules missing Alligatoring BlisteringMissing Tabs/Shingles/Tiles Moss buildup Exposed felt CuppingIncomplete/Improper Nailing Recommend roofer evaluate Evidence of Leakage
Comments
Skylights
X N/A Not Visible
Condition Cracked/Broken Satisfactory Marginal Poor
Comments
Plumbing Vents
Not Visible Not Present
Condition X Satisfactory Marginal Poor
Comments
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 11
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
ExteriorChimney(s)
None
Location(s)West
Viewed From Roof Ladder at eaves X Ground (Inspection Limited) With Binoculars
Rain Cap/Spark Arrestor Yes X No X Recommended
Chase X Brick Stone Metal Blocks Framed
Evidence of Holes in metal Cracked chimney cap X Loose mortar joints Flaking Loose brick RustNo apparent defects
Flue Tile Metal Unlined X Not Visible
Evidence of Scaling Cracks Creosote Not evaluated Have flue(s) cleaned and re-evaluatedRecommend Cricket/Saddle/Flashing No apparent defects
Condition Satisfactory X Marginal Poor Recommend Repair
Comments Chimney shows signs of scaling and loose brick as well as in need of repointing. Area where roof meets chimney is exposed and may allow for water intrusion.Recommend qualified licensed roofer and masonry contractors to evaluate entire roof and repair as needed.
Photos
Area where roof meets chimney. Chimney shows signs of loose brick and in need of repointing. Area where roof meets chimney may allow for water intrusion.Recommend qualified licensed roofer and masonry contractors to evaluate and repair as needed.
Gutters/Scuppers/Eavestrough
None
Condition X Satisfactory Marginal Poor Rusting Downspouts needed Recommend repair/replaceNeeds to be cleaned
Material Copper Vinyl/Plastic X Galvanized/Aluminum Other:
Leaking Corners Joints Hole in main run X No apparent leaks
Attachment Loose Missing spikes Improperly sloped X Satisfactory
Extension needed North South East X West N/A
Comments
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 12
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
ExteriorSiding
Material Stone Slate Block/Brick Fiberboard Fiber-cement Stucco EIFS* Not InspectedAsphalt Wood X Metal/Vinyl Other: Typical cracks Peeling paint Monitor Wood rotLoose/Missing/Holes
Condition X Satisfactory Marginal Poor Recommend repair/painting
Comments
Photos
Soffit
None
Material X Wood Fiberboard Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other:
Condition X Satisfactory Marginal Poor
Comments
Fascia
None
Material X Wood Fiberboard Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other:
Condition X Satisfactory Marginal Poor
Comments
Flashing
X None
Material Wood Fiberboard Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other:
Condition Satisfactory Marginal Poor
Comments
Caulking
None
Condition Satisfactory Marginal PoorX Recommend around windows/doors/masonry ledges/corners/utility penetrations
Comments
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 13
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
ExteriorWindows/Screens
Condition X Satisfactory Marginal Poor Wood rot Recommend repair/paintingRecommend repair/replace damaged screens Failed/fogged insulated glass
Material Wood Metal X Vinyl Aluminum/Vinyl clad
Screens Torn Bent Not installed X Satisfactory
Comments
Storms Windows
None Not installed
Condition X Satisfactory Broken/cracked Wood rot Recommend repair/painting
Material Wood Clad comb. X Wood/Metal comb. Metal
Putty Satisfactory Needed X N/A
Comments
Slab-On-Grade/Foundation
Foundation Wall Concrete block Poured concrete Post-Tensioned concrete X Not Visible Other:
Condition Satisfactory Marginal Monitor Have Evaluated X Not Evaluated
Concrete Slab N/A X Not Visible Satisfactory Marginal Monitor Have Evaluated
Comments
Service Entry
Location Underground X Overhead
Condition X Satisfactory Marginal Poor Weather head/mast needs repair X Overhead wires too low
Exterior receptacles Yes X No Operable: Yes No Condition: Satisfactory Marginal Poor
GFCI present Yes X No Operable: Yes No Safety Hazard Reverse polarity Open ground(s)X Recommend GFCI Receptacles
Comments Height of service entry line is below 8 feet and should be at least 10 feet above deck and not within 3 feet of window. Recommend qualified licensed electrical contractor to evaluate and repair as needed.
Photos
Service entry wires above window and deck.
Building(s) Exterior Wall Construction
Type Not Visible Framed X Masonry Other:
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 14
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
ExteriorBuilding(s) Exterior Wall Construction cont.
Condition Not Visible X Satisfactory Marginal Poor
Comments
Exterior Doors
Main Entrance N/A Weatherstripping: X Satisfactory Marginal Poor Missing ReplaceDoor condition: X Satisfactory Marginal Poor
Patio N/A Weatherstripping: X Satisfactory Marginal Poor Missing ReplaceDoor condition: X Satisfactory Marginal Poor
Rear door N/A Weatherstripping: X Satisfactory Marginal Poor Missing ReplaceDoor condition: X Satisfactory Marginal Poor
Other door X N/A Weatherstripping: Satisfactory Marginal Poor Missing ReplaceDoor condition: Satisfactory Marginal Poor
Comments
Exterior A/C - Heat pump #1
Unit #1 N/ALocation: 2nd floor deck. Brand: LG Model #: LMU18CHV Serial #:Approximate Age: Unknown
Condition X Satisfactory Marginal Poor Cabinet/housing rusted
Energy source X Electric Gas Other:
Unit type X Air cooled Water cooled Geothermal Heat pump
Outside Disconnect Yes X No Maximum fuse/breaker rating (amps): Fuses/Breakers installed (amps):Improperly sized fuses/breakers
Level X Yes No Recommend re-level unit
Condenser Fins Damaged Need cleaning Damaged base/pad Damaged Refrigerant Line X Satisfactory
Insulation X Yes No Replace
Improper Clearance (air flow) Yes X No
Comments No cut off switch at a/c .Switch should be within sight.
Photos
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 15
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Exterior
Heat pump at 2nd floor deck. Data plate. Heat pump data plate.
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 16
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Electric/Cooling SystemMain panel
Location Kitchen
Condition X Satisfactory Poor
Adequate Clearance to Panel Yes X No
Amperage/Voltage X Unknown 60a 100a 150a 200a 400a 120v/240v
Breakers/Fuses X Breakers Fuses
Appears grounded X Yes No Not Visible
GFCI breaker Yes X No Operable: Yes No
AFCI breaker Yes X No Operable: Yes No Not Tested
Main wire Copper X Aluminum Not Visible Double tapping of the main wireCondition: X Satisfactory Marginal Poor
Branch wire X Copper Aluminum Solid Branch Aluminum Wiring Not Visible Safety Hazard
Branch wire condition X Satisfactory Poor Recommend electrician evaluate/repair Romex BX cableConduit Knob/Tube X Double tapping Wires undersized/oversized breaker/fusePanel not accessible Not evaluated
Reason:
Comments Double tapped conductors at breaker.Recommend qualified licensed electrical contractor to evaluate and repair as needed. Access and working area to panel is limited. Main panel and breakers appear to be Square D , however some breakers are covered. Some data markings don't match interior markings. A/C unit not listed. Recommend qualified licensed electrical contractor to evaluate and repair as needed.
Photos
200 amp meter. Double tapped conductors at breaker.
Old conductors not capped off.
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 17
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Electric/Cooling System
Breakers covered over. Ground wire and grounding rod at floor below service panel.
Data plate needs to be updated and corrected.
Interior data markings of panel.
Sub panel(s)
X None apparent
Location(s) Location 1: Location 2: Location 3:
Evaluation Panel not accessible Not evaluatedReason:
Recommend separating/isolating neutrals Recommend electrician repair/evaluate box
Branch wire Copper Aluminum Safety hazard Neutral/ground separated: Yes NoNeutral isolated: Yes No
Condition Satisfactory Marginal Poor
Comments
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 18
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Heating SystemHeating system
Unit #1 Brand name: unknown. Approx. age: Unknown
Unknown Model #: Serial #: X Satisfactory Marginal PoorRecommended HVAC technician examine
Unit #2 X NoneBrand name: Approx. age:
UnknownModel #: Serial #: Satisfactory Marginal Poor Recommended HVAC technician examine
Energy source Gas LP Oil X Electric Solid fuel
Warm air system Belt drive Direct drive Gravity Central system X Floor/wall furnace
Heat exchanger X N/A Sealed Not Visible Visual w/mirror Flame distortion RustedCarbon/soot buildup
Carbon monoxide X N/A Detected at plenum Detected at register Not testedTester:
Combustion air venting present X N/A Yes No
Controls Disconnect: Yes X No Normal operating and safety controls observedGas shut off valve: Yes X No
Distribution Metal duct Insulated flex duct Cold air returns X Duct board Asbestos-like wrapSafety Hazard
Flue piping X N/A Satisfactory Rusted Improper slope Safety hazard Recommend repair/replace
Filter Standard Electrostatic Satisfactory Needs cleaning/replacement MissingX Electronic (not tested)
When turned on by thermostat X Fired Did not fire Proper operation: X Yes No Not tested
Heat pump N/A X Supplemental electric Supplemental gas
Sub-slab ducts X N/A Satisfactory Marginal Poor Water/Sand Observed: Yes No
System not operated due to X N/A Exterior temperature Other:
Comments Blower units are located at wall in dining room and at 2nd floor wall outside of bathroom.Due to cold temperatures,the air conditioning component was not evaluated.
Photos
Heating and cooling blower.
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 19
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Heating SystemBoiler system
X N/A
General Brand name: Approx. age: Model #: Serial #:
Energy source Gas LP Oil Electric Solid fuel
Distribution Hot water Baseboard Steam Radiator Radiant floor
Circulator Pump Gravity Multiple zones
Controls Temp/pressure gauge exist: Yes No Operable: Yes No
Oil fired units Disconnect: Yes No
Combustion air venting present Yes No N/A
Relief valve Yes No Missing Extension proper: Yes No Recommend repair/replace
Operated When turned on by thermostat: Fired Did not fire
Operation Satisfactory: Yes No Recommend HVAC technician examine before closing
Comments
Other systems
X N/A
Type Electric baseboard Radiant ceiling cable Gas space heater Solid fuel burning stove
Proper operation Yes No
System condition Satisfactory Marginal Poor Recommend HVAC Technician Examine
Comments
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 20
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
PlumbingWater service
Main shut-off location kitchen
Water entry piping Not Visible X Copper/Galv. PVC Plastic CPVC Plastic Polybutylene PlasticPEX Plastic Lead Polyethylene
Lead other than solder joints Yes X No Unknown Service entry
Visible water distribution piping X Copper Galvanized PVC Plastic CPVC Plastic Polybutylene PlasticPEX Plastic Other:
Condition X Satisfactory Marginal Poor
Flow X Satisfactory Marginal Poor Water pressure over 80 psi Recommend plumber evaluateRecommend pressure regulator
Pipes Supply/Drain Corroded Leaking Valves broken/missing Dissimilar metalCross connection: Yes X No Safety Hazard Recommend repair
Recommend a dielectric union X Satisfactory
Drain/Waste/Vent pipe Copper Cast iron Galvanized X PVC ABS Brass
Condition X Satisfactory Marginal Poor
Support/Insulation X N/AType:
Traps proper P-Type X Yes No P-traps recommended
Drainage X Satisfactory Marginal Poor
Interior fuel storage system X N/A Yes No Leaking: Yes No
Fuel line X N/A Copper Brass Black iron Stainless steel CSST Not Visible GalvanizedRecommend CSST be properly bonded
Condition N/A X Satisfactory Marginal Poor Recommend plumber evaluate
Comments Main shut off in kitchen.
Photos
Main water shut off.
Main fuel shut-off location
N/A
Location In kitchen.
Comments
Well pump
X N/A
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 21
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
PlumbingWell pump cont.
Type Submersible In basement Well house Well pit Shared well
Pressure gauge operable Yes No Well pressure: Not Visible
Comments
Sanitary/Grinder pump
X N/A Operable: Yes No
Sealed Crock Sealed crock: Yes No
Check Valve Check valve: Yes No
Shut-off Valve Shut-off valve: Yes No
Vented Yes No
Comments
Water heater #1
N/A
General Brand Name: Tempra Serial #:Capacity: Approx. age: unknown.
Type Gas X Electric Oil LP Other:
Combustion air venting present Yes No X N/A
Seismic restraints needed Yes No X N/A
Relief valve Yes X NoExtension proper: Yes No Missing Recommend repair Improper material
Vent pipe X N/A Satisfactory Pitch proper Improper Rusted Recommend repair
Condition X Satisfactory Marginal Poor
Comments
Photos
Tankless hot water heater.
Water softener
X None
Loop installed Yes No
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 22
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
PlumbingWater softener cont.
Plumbing hooked up Yes No
Plumbing leaking Yes No
Comments
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 23
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Laundry RoomLaundry
Laundry sink X N/A
Faucet leaks Yes X No
Pipes leak Yes X No Not Visible
Cross connections Yes X No Potential Safety Hazard
Heat source present Yes X No
Room vented Yes X No
Dryer vented N/A Wall Ceiling X Floor Not vented Plastic dryer vent not recommendedNot vented to exterior Recommend repair Safety hazard
Electrical Open ground/reverse polarity: Yes X No Safety hazard
GFCI present Yes X No Operable: Yes No X Recommend GFCI Receptacles
Appliances X Washer Dryer Water heater Furnace/Boiler
Washer hook-up lines/valves X Satisfactory Leaking Corroded Not Visible
Gas shut-off valve X N/A Yes No Cap Needed Safety hazard Not Visible
Comments Electrical supply is to an extension cord behind wall. It is difficult to see and access.Recommend qualified licensed electrical contractor to evaluate and install dedicated line and proper receptacle .
Photos
Connection to washer. Washer / dryer unit.
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 24
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
KitchenCountertops
Condition X Satisfactory Marginal Recommend repair/caulking
Comments trip hazard exiting kitchen.
Photos
Cabinets
Condition X Satisfactory Marginal Recommend repair/adjustment
Comments minor adjustment needed to close cabinet door.
Photos
Cabinet door.
Plumbing
Faucet Leaks Yes X No
Pipes leak/corroded Yes X No
Sink/Faucet X Satisfactory Corroded Chipped Cracked Recommend repair
Functional drainage X Satisfactory Marginal Poor
Functional flow X Satisfactory Marginal Poor
Comments
Walls & Ceiling
Condition X Satisfactory Marginal Poor Typical cracks Moisture stains
Comments
Heating/Cooling Source
X Yes No
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 25
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
KitchenFloor
Condition X Satisfactory Marginal Poor Sloping Squeaks
Comments Exit from kitchen to dining room has a elevated edge that is a trip hazard.
Photos
Elevation from kitchen to dining room.
Appliances
Disposal N/A Not tested Operable: X Yes No
Oven X N/A Not tested Operable: Yes No
Range N/A Not tested Operable: X Yes No
Dishwasher N/A Not tested Operable: X Yes No
Trash Compactor X N/A Not tested Operable: Yes No
Exhaust fan N/A Not tested Operable: X Yes No
Refrigerator N/A Not tested Operable: X Yes No
Microwave N/A Not tested Operable: X Yes No
Other Operable: Yes No
Dishwasher airgap Yes X No
Dishwasher drain line looped X Yes No
Receptacles present X Yes No Operable: X Yes No
GFCI Yes X No Operable: Yes No Recommend GFCI Receptacles: X Yes NoPotential Safety Hazard(s)
Open ground/Reverse polarity: Yes X No Potential Safety Hazard
Comments Light over range flickers on low setting . Microwave and toaster are connected to extention cord connected to a receptacle at other end of room. Recommend qualified electrical contractor to evaluate and install dedicated receptacle for microwave. Caulk and seal wall around water shut off.
Photos
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 26
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Kitchen
Refrigerator. Garbage disposal and wall that needs to be sealed.
Extention cord for toaster and microwave.
Range
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 27
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
MasterbathBath
Location 2nd fl
Sinks Faucet leaks: Yes X No Pipes leak: Yes X No
Tubs X N/A Faucet leaks: Yes No Pipes leak: Yes No Not Visible
Showers N/A Faucet leaks: Yes X No Pipes leak: Yes X No Not Visible
Toilet Bowl loose: Yes X No Operable: X Yes No Cracked bowl Toilet leaks
Whirlpool Yes X No Operable: Yes No Not tested No access door GFCI: Yes NoGFCI Recommended
Shower/Tub area X Ceramic/Plastic Fiberglass Masonite Other:Condition: X Satisfactory Marginal Poor Rotted floorsCaulk/Grouting needed: Yes X NoWhere:
N/A
Drainage X Satisfactory Marginal Poor
Water flow X Satisfactory Marginal Poor
Moisture stains present Yes X No Walls Ceilings Cabinetry
Doors X Satisfactory Marginal Poor
Window None X Satisfactory Marginal Poor
Receptacles present X Yes No Operable: X Yes No
GFCI X Yes No Operable: X Yes No Recommend GFCI
Open ground/Reverse polarity Yes X No Potential Safety Hazard
Heat source present Yes X No
Exhaust fan Yes X No Operable: Yes No Noisy
Comments
Photos
Sink Plumbing behind drawers. Shower
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 28
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
MasterbedroomRoom
Location Second floor
Type MASTER BEDROOM
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor Squeaks Slopes Tripping hazard
Ceiling fan X None Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: X Yes No Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Bedroom Egress restricted N/A Yes X No
Doors None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware
Windows None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments Open ground in bedroom .Recommend qualified licensed electrical contractor to evaluate and repair as needed.
Photos
Masterbedroom Several open grounds in bedroom.
Open ground.
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 29
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
InteriorFireplace
X None
Location(s)
Type Gas Wood Solid fuel burning stove Electric Ventless
Material Masonry Metal (pre-fabricated) Metal insert Cast Iron
Miscellaneous Blower built-in Operable: Yes No Damper operable: Yes NoOpen joints or cracks in firebrick/panels should be sealed Fireplace doors need repair
Damper modified for gas operation N/A Yes No Damper missing
Hearth extension adequate Yes No
Mantel N/A Secure Loose Recommend repair/replace
Physical condition Satisfactory Marginal Poor Recommend having flue cleaned and re-examinedNot evaluated
Comments
Stairs/Steps/Balconies
None
Condition X Satisfactory Marginal Poor Loose/Missing
Handrail Satisfactory Marginal Poor X Safety hazard X Hand Rail/Railing/Balusters recommended
Risers/Treads X Satisfactory Marginal Poor Risers/Treads uneven Trip hazard
Comments
Photos
No handrails. No handrails. Light switch for stairs.
Smoke/Carbon Monoxide detectors
Smoke Detector X Present Not Present Operable: Yes No X Not tested Recommend additionalSafety Hazard
CO Detector Present X Not Present Operable: Yes No Not tested Recommend additionalSafety Hazard
Comments Buyer should install all new smoke detectors in home.
Photos
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 30
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Interior
Smoke detector behind curtain. Curtain in front of smoke detector.
Attic/Structure/Framing/Insulation
X N/A
Access Stairs Pulldown Scuttlehole/Hatch No Access Other: Access limited by:
Inspected from Access panel In the attic Other
Location Hallway Bedroom Closet Garage Other
Flooring Complete Partial None
Insulation Fiberglass Batts Loose Cellulose Foam Other Vermiculite Rock woolDepth: Damaged Displaced Missing Compressed Recommend additional insulation
Installed in Rafters/Trusses Walls Between ceiling joists Underside of roof deck Not Visible
Vapor barriers Kraft/foil faced Plastic sheeting Not Visible Improperly installed
Ventilation Ventilation appears adequate Recommend additional ventilation Recommend baffles at eaves
Fans exhausted to Attic: Yes No Recommend repair Outside: Yes No Not Visible
HVAC Duct N/A Satisfactory Damaged Split Disconnected Leaking Repair/ReplaceRecommend Insulation
Chimney chase N/A Satisfactory Needs repair Not Visible
Structural problems observed Yes No Recommend repair Recommend structural engineer
Roof structure Rafters Trusses Wood Metal Collar ties Purlins Knee wall Not Visible Other:
Ceiling joists Wood Metal Not Visible
Sheathing Plywood OSB Planking Rotted Stained Delaminated
Evidence of condensation Yes No
Evidence of moisture Yes No
Evidence of leaking Yes No
Firewall between units N/A Yes No Needs repair/sealing
Electrical No apparent defects Open junction box(es) Handyman wiringKnob and tube covered with insulation Safety Hazard
Comments
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 31
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Living RoomLiving Room
Location First floor
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor Squeaks Slopes Tripping hazard
Ceiling fan X None Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: Yes X No Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Doors None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware
Windows None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments turned in.
Photos
One joist appears to have turned slightly.Buyer should monitor situation and consult a structural engineer if situation changes.
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
1 Sample Dr., Your City, MD 22222 Page 32
This confidential report is prepared exclusively for My Client My Client©2017 Dan Block
Dining RoomDining Room
Location First floor
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor Squeaks Slopes Tripping hazard
Ceiling fan X None Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: Yes X No Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Doors None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware
Windows None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments