Home Circuit Protection

Embed Size (px)

Citation preview

  • 7/28/2019 Home Circuit Protection

    1/14186

    Homecircuitprotection

    Irish consumer

    units

    Supply unitsIP 55

    Consumer units

    P. 192Insulatedcustom build

    P. 197Dimensions

    P. 193Accessories

    P. 198Garage/outbuildingsupply units

    P. 195Irish consumer units,protection andmodular devices

    P. 190Insulatedsurface mountingselection chart

    P. 190Metalsurface mountingselection chart

    P. 190Metalflush mountingselection chart

    High integrity dualRCD split loadInsulated consumer unit(p. 192)

    NEW IN 2010

    Dual RCD splitloadInsulated consumerunit

    (p. 192)

  • 7/28/2019 Home Circuit Protection

    2/14187

    P. 192Insulated highintegrity dualRCD split load

    P. 192Insulated dualRCD split load

    P. 192Insulatedsplit load

    P. 192Insulatedwith incomer

    P. 193Metalcustom buildflushmounting

    P. 198Dimensions

    P. 196Dimensions

    P. 193Metal dual RCDsplit load

    P. 193Metalwith incomer

    P. 194Isolatingswitches andcontactors

    P. 194MCBs,RCDs andRCBOs

    P. 198Electric showersupply units

    P. 193Metalcustom build

    P. 194Transformers

    P. 193Metalsplit load

    P. 193Metal dualRCD splitload flushmounting

    Single moduleRCBO(p. 194)

  • 7/28/2019 Home Circuit Protection

    3/14188

    Legrand's latest selection of consumer units comply perfectly with the 17th Edition...

    including our range of new dual RCD split load units with 10 or 16 outgoing ways.

    With an array of design innovations and practical features

    making them easy to install, Legrands insulated and

    metal consumer units save valuable time and money

    during installation... allowing you to reflect on the

    generous wiring space and the all-round extra protection.

    COMBINING ELEGANCE WITH EFFICIENCY

    Designed to match todays modern decor, the units offer a

    streamlined appearance allied with magnolia cases,

    allowing them to blend perfectly into their surroundings.

    A range of new semi-flush solutions and lockable brackets

    are also available to meet changing market requirements.

    Greater protectionsimplifying the 17th Edition

  • 7/28/2019 Home Circuit Protection

    4/14189

    FIND OUT MORE

    iInsulated consumer units

    See p. 192

    Metal consumer units

    See p. 193

    Irish consumer units

    See p. 195

    DUAL RCD SPLIT LOAD

    WITH DEDICATED MAIN

    SWITCH WAYS

    Select MCBs and RCBOs tocomplete installation

    DUAL RCD SPLIT LOAD

    Select MCBs to

    complete installation

    SPLIT LOAD

    Select MCBs and RCBOs to

    complete installation

    MAIN SWITCH INCOMER

    Select RCBOs to

    complete installation

    RCD INCOMER

    Select MCBs to

    complete installation

    IRISH CONSUMER UNITS

    The Legrand wiring

    devices catalogue now

    contains a selection of

    consumer units and

    protection devices

    designed specifically

    for the Irish market.

    i

    i

  • 7/28/2019 Home Circuit Protection

    5/14190

    consumer unitsinsulated and metal

    High integrity dual RCD splitload with 2 unprotected ways100 A main switch and

    2 x 80 A 30 mA RCD

    Dual RCD split load100 A main switch and

    2 x 80 A 30 mA RCD

    Split load100 A main switch and

    80 A 30 mA RCD

    Split load dual tariff2 x 100 A main switch and 80

    A 30 mA RCD

    Main switch incomer63 A main switch

    Main switch incomer100 A main switch

    RCD incomer80 A 30 mA RCD

    Custom build

    Insulated consumer units

    Total outgoing ways

    Conform to BS EN 60439-3. RAL 9001. Magnolia colour. Smoked transparent door opens downwardsSupplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plateFactory fitted link leads for both neutral and live connections. Configurable outgoing ways

    Self-extinguishing at 750C. UL 94 V2 material for improved flame retardancy. Robust thermoplastic construction. 4 fixing holes

    Metal consumer units

    Conform to BS EN 60439-3. RAL 9001. Magnolia colour. Smoked transparent door opens downwardsSupplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plateFactory fitted link leads for both neutral and live connections. Configurable outgoing waysPre-galvanised steel for strength and rigidity. Epoxy/polyester powder coated base and lid

    (1) Flush mounting

    2 4 6 8 10 12 14 16 18 20 22

    6075 74 6075 76

    6075 54 6075 56

    6075 32 6075 33 6075 34 6075 35 6075 36

    6075 46

    6075 10

    6075 11 6075 12 6075 14 6075 16

    6075 21 6075 22

    6075 00 6075 01 6075 02 6075 04 6075 06

    Dual RCD split load100 A main switch and

    2 x 80 A 30 mA RCD

    Split load100 A main switch and

    80 A 30 mA RCD

    Main switch incomer100 A main switch

    RCD incomer80 A 30 mA RCD

    Custom build

    Total outgoing ways

    6 8 10 12 14 16 18 20 22

    6065 54

    6065 56 6065 64(1)

    6065 32 6065 34 6065 36

    6065 11 6065 12 6065 14 6065 16

    6065 21 6065 22

    6065 01 6065 02

    6065 04

    6065 066065 42(1) 6065 42(1)

    Dimensions (p. 196)

    Dimensions(p. 197-198)

  • 7/28/2019 Home Circuit Protection

    6/14191

    0032 70

    6 A

    10 A

    16 A

    20 A

    25 A

    32 A

    40 A

    50 A

    63 A

    Nominal rating (In)Numberof17.5 mmmodules

    1 0032 66 0033 82 1 6064 16 6064 22

    1 0032 68 0033 84 1 6064 17 6064 23

    1 0032 70 0033 86 1 6064 18 6064 24

    1 0032 71 0033 87 1 6064 19 6064 25

    1 0032 72 0033 88

    1 0032 73 0033 89 1 6064 20 6064 26

    1 0032 74 0033 90 1 6064 21 6064 27

    1 0032 75 0033 91 1 6064 28 6064 29

    1 0032 76 0033 92

    protection devicesMCBs and RCBOs

    DX-E residential MCBs - 6 kASingle pole - 230/400 V

    RCBOs (combined MCB/RCD)Single pole and neutral - 240 V

    B curve C curve

    30 mANumberof17.5 mmmodules

    B curve C curve

    DX-E residential MCBs - 6 kABreaking capacity :6 kA to BS EN 60898-1

    RCBOs (combined MCB/RCD)Breaking capacity :10 kA to BS EN 61009-1

    RCD type AC conform toBS EN 61009-1

    Terminal capacity :rigid conductor 35mm2

    flexible conductor 25mm2

    6064 25

  • 7/28/2019 Home Circuit Protection

    7/14192

    insulated consumer unitssurface mounting

    Insulated split load - surface mounting

    Factory fitted link leads for both neutral andlive connectionsConfigurable outgoing ways

    12 module unit

    1 6075 32 With 100 A main switch and 80 A 30 mA RCD(8 ways available)

    14 module unit

    1 6075 33 With 100 A main switch and 80 A 30 mA RCD(10 ways available)

    16 module unit

    1 6075 34 With 100 A main switch and 80 A 30 mA RCD(12 ways available)

    20 module unit

    1 6075 35 With 100 A main switch and 80 A 30 mA RCD(16 ways available)

    22 module unit

    1 6075 36 With 100 A main switch and 80 A 30 mA RCD(18 ways available)

    Pack Cat. Nos. Insulated split load dual tariff -surface mounting

    Factory fitted link leads for both neutral andlive connectionsOffers cost effective energy management throughindependent control of each tariffFlexible configurable outgoing ways

    22 module unit

    1 6075 46 With 2 x 100 A main switch and 80 A 30 mA RCD(16 ways available)

    Lockable consumer unit bracket available onrequest

    Semi flush solutions available on request

    Conform to BS EN 60439-3. RAL 9001 - magnolia colourSelf-extinguishing at 750 C - UL 94 V2 material for improved flame retardancyRobust, rigid thermoplastic construction with 4 fixing holes. Smoked transparent door opens downwardsSupplied with neutral and earth terminals completely assembledSupplied with 5 module spare blank plate (except 4 module unit)MCBs to be ordered separately, (see p. 194)

    6075 10 6075 216075 54

    Dimensions (p. 196)

    see p. 194

    For DX-E residential MCBs andsingle module RCBOs

    see p. 194

    For lockable consumer unitbracket and semi flush solutions

    6075 74

    Pack Cat. Nos. Insulated high integrity dual RCD split loadwith 2 unprotected ways - surface mounting

    16 module unit (8 + 2 ways available)

    1 6075 74 With 100 A main switch and 2 x 80 A 30 mA RCD

    22 module unit (13 + 3 ways available)

    1 6075 76 With 100 A main switch and 2 x 80 A 30 mA RCD

    Insulated dual RCD split load - surfacemounting

    16 module unit (10 ways available)

    1 6075 54 With 100 A main switch and 2 x 80 A 30 mA RCD

    22 module unit (16 ways available)1 6075 56 With 100 A main switch and 2 x 80 A 30 mA RCD

    Insulated with incomer - surface mounting

    4 module unit1 6075 10 With 63 A main switch (2 ways available)

    8 module unit

    1 6075 11 With 100 A main switch (6 ways available)1 6075 21 With 80 A 30 mA RCD (6 ways available)

    12 module unit

    1 6075 12 With 100 A main switch (10 ways available)1 6075 22 With 80 A 30 mA RCD (10 ways available)

    16 module unit

    1 6075 14 With 100 A main switch (14 ways available)

    22 module unit

    1 6075 16 With 100 A main switch (20 ways available)

    Insulated custom build - surface mounting

    Allow several configurations when using kits andincomers (isolating switches, RCDs, RCBOs)For kits, (see p. 193)For incomers and outgoing devices, (see p. 194)

    1 6075 00 4 modules available

    1 6075 01 8 modules available

    1 6075 02 12 modules available

    1 6075 04 16 modules available

    1 6075 06 22 modules available

  • 7/28/2019 Home Circuit Protection

    8/14193

    Metal custom build - surface mounting

    Epoxy/polyester powder coated base and lidStand-off feet complete with keyhole fixingAllow several configurations when using kits andincomers (isolating switches, RCDs, RCBOs)For kits, (see opposite)

    For incomers and outgoing devices, (see p. 194)1 6065 01 8 modules available

    1 6065 02 12 modules available

    1 6065 04 16 modules available

    1 6065 06 22 modules available

    Finishing accessories

    White blanking plate RAL 901010 0016 64 18 module, separable by single or half modules

    Self-adhesive label holder10/100 0049 96 Width : 16 mm

    Width available for marking : 12 mmLength 530 mm (24 modules)

    Metal with incomer - surface mounting

    Epoxy/polyester powder coated base and lidStand-off feet complete with keyhole fixing

    8 module unit

    1 6065 11 With 100 A main switch (6 ways available)

    1 6065 21 With 80 A 30 mA RCD (6 ways available)12 module unit

    1 6065 12 With 100 A main switch (10 ways available)1 6065 22 With 80 A 30 mA RCD (10 ways available)

    16 module unit

    1 6065 14 With 100 A main switch (14 ways available)

    22 module unit

    1 6065 16 With 100 A main switch (20 ways available)

    Metal split load - surface mounting

    Epoxy/polyester powder coated base and lidStand-off feet complete with keyhole fixingFactory fitted link leads for both neutral andlive connectionsConfigurable outgoing ways

    12 module unit1 6065 32 With 100 A main switch and 80 A 30 mA RCD

    (8 ways available)

    16 module unit

    1 6065 34 With 100 A main switch and 80 A 30 mA RCD(12 ways available)

    22 module unit

    1 6065 36 With 100 A main switch and 80 A 30 mA RCD(18 ways available)

    metal consumer units and accessoriessurface and flush mounting

    Conform to BS EN 60439-3. RAL 9001 - magnolia colourPre-galvanised steel for strength and rigiditySmoked transparent door opens downwardsSupplied with neutral and earth terminals completely assembledSupplied with 5 module spare blank plateMCBs to be ordered separately, (see p. 194)

    6065 216065 54 6065 06

    Dimensions (p. 197-198)

    0044 41

    0049 96

    Accessories

    Incomer or dual tariff kit

    1 6075 19 Comprises : 1 flexible neutral (blue) lead1 rigid neutral link

    Split load kit1 6075 39 Comprises : 1 flexible live (brown) lead

    1 flexible neutral (blue) lead2 rigid neutral links

    Split load dual tariff kit (for insulated units only)1 6075 49 Comprises : 1 flexible live (brown) lead

    2 flexible neutral (blue) leads2 rigid neutral links1 neutral terminal

    Spare blank plate20 6075 89 5 modules - magnolia colour

    Spare busbar5 6075 99 21 prongs

    Spacing elements10 0044 40 05 module5 0044 41 1 module

    Locking device for MCBs and RCDs2 0044 42 Locking attachment for 4 mm and

    6 mm padlocks

    Padlock for MCBs and RCDs1/3 0044 43 Padlock 4 m

    Spare terminal block? 8204 07 13 hole

    Pack Cat. Nos. Metal dual RCD split load - surface mounting

    16 module unit (10 ways available)

    1 6065 54 With 100 A main switch and 2 x 80 A 30 mA RCD

    22 module unit (16 ways available)

    1 6065 56 With 100 A main switch and 2 x 80 A 30 mA RCD

    Pack Cat. Nos. Metal dual RCD split load - flush mounting

    16 module unit (10 ways available)

    1 6065 64 With 100 A main switch and 2 x 80 A 30 mA RCD

    Metal custom build - flush mounting

    Epoxy/polyester powder coated lid

    1 6065 42 12 modules available

    1 6065 44 16 modules available

  • 7/28/2019 Home Circuit Protection

    9/14194

    consumer unitsprotection and control devices

    Pack Cat. Nos. DX-E residential MCBs - 6 kA

    Breaking capacity : 6 kA to BS EN 60898-1

    Single pole - 230/400 VB curve C curve Nominal rating Number of (In) 175 mm modules

    10 0032 66 0033 82 6 A 110 0032 68 0033 84 10 A 110 0032 70 0033 86 16 A 110 0032 71 0033 87 20 A 110 0032 72 0033 88 25 A 110 0032 73 0033 89 32 A 110 0032 74 0033 90 40 A 110 0032 75 0033 91 50 A 110 0032 76 0033 92 63 A 1

    RCBOs (combined MCB/RCD) -Dual module

    Breaking capacity : 10 kA to BS EN 61009-1RCD type AC conform to BS EN 61009-1

    Terminal capacity : rigid conductor 35 mm2

    flexible conductor 25 mm2

    Single pole and neutral - 230/400 VB curve C curve Nominal rating Number of

    (In) 175 mm modules30 mA

    1 0077 31 0077 38 6 A 21 0077 32 0077 39 10 A 21 0077 33 0077 40 16 A 21 0077 34 0077 41 20 A 21 0077 36 0077 43 32 A 21 0077 37 0077 44 40 A 2

    DX multi-purpose MCBs - 6 kA

    Breaking capacity : 6 kA to BS EN 60898-1

    Single pole - 230/400 VB curve C curve Nominal rating Number of

    (In) 175 mm modules

    10 1 0061 56 0063 72 6 A 110 10 0061 58 0063 74 10 A 110 10 0061 60 0063 76 16 A 110 1 0061 61 0063 77 20 A 110 1 0061 63 0063 79 32 A 11 1 0061 64 0063 80 40 A 11 1 0061 65 0063 81 50 A 11 1 0061 66 0063 82 63 A 1

    0043 360089 12 0040 49 0042 200077 31

    Pack Cat. Nos. DX residual current devices (RCDs)

    Conform to BS EN 61008-1

    Terminal capacity : rigid conductor 35 mm2

    flexible conductor 25 mm2

    Double pole 230 V

    Type AC Nominal rating Number of (In) 175 mm modules

    30 mA1 0089 09 25 A 21 0089 10 40 A 21 0089 11 63 A 21 0089 12 80 A 21 6027 10 100 A 2

    100 mA1 0089 15 25 A 21 0089 16 40 A 21 0089 17 63 A 21 0089 18 80 A 2

    100 mA discriminating

    1 6027 11 100 A 2

    Isolating switches

    Conform to BS EN 60947-3, IEC 60669-1Usage : AC 22 according to IEC 60947-3Red handleDouble break contacts, padlockable50 mm2 capacity shielded terminals

    Number of175 mm modules

    5 0043 31 63 A double pole 25 0043 36 100 A double pole 2

    Contactor with 230 V coil

    Conforms to EN 61095

    Double pole (L + N) 250 V

    230 V coil circuitType of Number of

    I max. contact 175 mmmodules

    1 0040 49 20 A 2 N/O 1

    Transformers

    Bell transformers with label holder 230 VConform to BS EN 61558-2-8

    Secondary Rating Power Number of

    175 mm modules

    1 0042 20 8 V 05 A 4 VA 21 0042 25 8/12 V 1/066 A 8 VA 2

    230 V

    0032 70 6064 16

    RCBOs (combined MCB/RCD) -Single module

    Breaking capacity : 10 kA to BS EN 61009-1RCD type AC conform to BS EN 61009-1

    Terminal capacity : rigid conductor 35 mm2

    flexible conductor 25 mm2

    Single pole and neutral - 240 VB curve C curve Nominal rating Number of

    (In) 175 mm modules30 mA

    1 6064 16 6064 22 6 A 11 6064 17 6064 23 10 A 11 6064 18 6064 24 16 A 11 6064 19 6064 25 20 A 11 6064 20 6064 26 32 A 11 6064 21 6064 27 40 A 11 6064 28 6064 29 50 A 1

  • 7/28/2019 Home Circuit Protection

    10/14195

    Irish consumer unitsprotection devices and modular devices

    Pack Cat. Nos. Insulated consumer units

    IEC 60439 IP30 IK05 Class 2 O230 V 50Hz operating voltageSurface mountingSupplied completely assembled with neutral andearth terminals

    Insulated reversible back plate and doorColour : white RAL 9010Supplied complete with a set of pre-printed labels inEnglish and Irish for use with MCBs and RCDsSupplied with blanking plates

    Each consumer unit is fitted with : 63 A Neozed fuse unit complete with fuse 2 x 10 A type B MCBs 32 A type B MCB 63 A 30 mA RCD 4 x 20 A type B MCBs

    Dimensions (mm)Height x Width x Depth

    1 6010 60 1 row unit 235 x 250 x 1201 6010 61 2 row unit 360 x 250 x 1201 6010 62 3 row unit 485 x 250 x 120

    AccessoriesWhite doors

    1 0013 31 For 1 row unit1 0013 32 For 2 row unit

    Transparent doors

    1 0013 41 For 1 row unit1 0013 42 For 2 row unit

    Clip-on blanking plates, white RAL 703S

    20 0016 60 5 modules separable by module or half module20 0016 62 13 modules separable by module or half module

    Joining accessories

    Consisting of spacers and an arched cable gland forjoining 2 units together

    1 0013 92 Vertical (across whole width)

    6010 60

    0013 42

    0013 31

    6010 61

    (1) Min. protection for Icc max : 10 kA

    Please note : The products shown on this pagerepresent the most commonly used items in the range.Additional versions, including surface and flushboards, are also available on request.

    DX-E residential MCBs - 6 kA

    Short circuit capacity : 6 000 A (IS EN 60898-1)Type B 6 kA

    Single pole (1 protected pole) 230/400 VB curve Nominal rating Number of

    (In) 175 mm modules

    1 0032 68 10 A 11 0032 71 20 A 11 0032 73 32 A 11 0032 74 40 A 1

    Specials available on request

    Pack Cat. Nos. Residual current devices (RCDs)

    Type ACConform to IS EN 61008-1

    Double pole 230 VType AC Nominal rating Number of

    (In) 175 mm modules

    30 mA sensitivity1 0086 29 40 A 21 0086 30 63 A 2

    DX RCBOs - 10 kA

    Conform to BS EN 61009-1Breaking capacity : 10 kA to BS EN 61009-1Type B MCB and 30 mA RCD protection

    B curve Nominal rating Number of (In) 175 mm modules

    1 0077 78 10 A 21 0077 80 16 A 21 0077 81 20 A 21 0077 83 32 A 21 0077 84 40 A 2

    Bells and buzzer

    50 Hz ACConnection by screw terminals, with label holderBells - IP 30-1

    NumberVoltage Power Consum. P (1) of 175 mm(V) (VA) (mA) (dB) modules

    10 0041 01 8/12 4/5 360/420 80/84 110 0041 07 230 6 27 83 1

    Buzzer- IP 30-110 0041 13 230 6 27 73 1

    Bell transformers

    d Conform to IEC / EN 61558-2-8Transformers protected against overloadsand short circuitsPossibility for supply busbars to run through(Cat. Nos. 0042 20/25)

    DepthNumber

    60 mmSecondary Rating Power of 175 mm

    modules

    230 V / 8 V

    1 0042 20 8 V 05 A 4 VA 2230 V / 12 V - 8 V

    1 0042 25 12/8 V 066/1 A 8 VA 2

    0086 30 0041 07 0041 13

    Spare terminals available (p. 294)Modular timers (p. 230)

    Voltage surge protectorFor neutral earthing : TT, TN, IT, Uc = 440 V

    Type 1 : Iimp = 10 kA (impulse discharge cap.10/350 s wave)Type 2 : In = 20 kA; Up = 2 kV (protection level)Imax = 70 kA (impulse discharge cap. 8/20 s)

    Numberof 175mm

    Associated protection modules

    1 0039 20 Single pole 0068 64 1

    Voltage surge protection technical information (p. 199)

  • 7/28/2019 Home Circuit Protection

    11/14

    insulated consumer unitssurface mounting

    B

    A 110

    50

    195

    40 5

    0

    20

    90

    4 cut-outs

    20 x 25

    1 cut-out

    40 x 50

    1 cut-out

    50 x 50

    4 cut-outs 20 x 25

    225

    114

    4 cut-outs

    25 x 25

    2 cut-outs

    20 x 25

    s Insulated - surface mounting dimensions (mm)

    s 4 module unitBack box fixing centres and cable entries (mm)

    225

    114

    162

    6 cut-outs

    20 x 25

    8 cut-outs

    25 x 25

    6 cut-outs 20 x 25

    2 cut-outs

    50 x 50

    2 cut-outs

    40 x 50

    40 5

    0

    20

    2 cut-outs

    20 x 25

    s 8 module unitBack box fixing centres and cable entries (mm)

    225

    180

    268

    2 cut-outs

    50 x 50

    2 cut-outs

    40 x 50

    40 5

    0

    20

    6 cut-outs

    20 x 25

    2 cut-outs

    20 x 18.5

    2 cut-outs 20 x 18.5

    22 cut-outs

    25 x 20

    2 cut-outs 20 x 25

    2 cut-outs

    20 x 25

    40 5

    0

    20

    10 cut-outs 20 x 25

    2 cut -outs 50 x 50 2 cut-outs 40 x 50

    30 cut-outs 25 x 20

    225

    180

    340

    8 cut-outs 20 x 25

    2 cut-outs

    20 x 25

    s 12 module unitBack box fixing centres and cable entries (mm)

    s 14/16 module unitBack box fixing centres and cable entries (mm)

    s 20/22 module unitBack box fixing centres and cable entries (mm)

    Modules A (mm) B (mm)

    4 140 225

    8 212 225

    12 298 225

    14/16 370 225

    20/22 478 225

    View from

    sides

    View from

    below

    View from

    above

    View from

    sides

    View from

    below

    View from

    above

    View from

    sides

    View from

    below

    View from

    above

    View from

    sides

    View from

    below

    View from

    above

    10 cut-outs 20 x 252 cut-outs 20 x 22

    2 cut-outs 20 x 22 12 cut-outs 20 x 25 42 cut-outs 25 x 20

    225

    180

    448

    2 cut-outs

    20 x 25

    40 5

    0

    20

    2 cut-outs 50 x 50 2 cut-outs 40 x 50

    View from

    sides

    View from

    below

    View from

    above

    196

  • 7/28/2019 Home Circuit Protection

    12/14197

    metal consumer unitssurface mounting

    B

    A 113

    50

    200

    4 cut-outs 32

    1 cut-out 25

    5

    9

    1 obround

    cut-out 100 x 50

    4

    3

    95

    80

    100

    s Metal - surface mounting dimensions (mm)

    s 8 module unit

    Back box fixing centres and cable entries (mm)

    4 cut-outs 32

    2 cut-outs 252 cut-outs 20

    1 obround

    cut-out 100 x 50

    95

    80

    175

    100

    s 12 module unit

    Back box fixing centres and cable entries (mm)

    4 cut-outs 20

    4 cut-outs 324 cut-outs 25

    2 obround

    cut-outs 100 x 50

    95

    80

    250

    120

    175

    s 16 module unit

    Back box fixing centres and cable entries (mm)

    4 cut-outs 25

    4 cut-outs 328 cut-outs 20

    2 obround

    cut-outs 100 x 50

    95

    80

    350

    120

    275

    s 22 module unit

    Back box fixing centres and cable entries (mm)

    Modules A (mm) B (mm)

    8 219 235

    12 305 235

    16 377 235

    22 485 235

    View from

    below

    View from

    above

    View from

    below

    View from

    above

    View from

    below

    View from

    above

    View from

    below

    View from

    above

  • 7/28/2019 Home Circuit Protection

    13/14

    metal consumer unitsflush mounting

    B230

    50

    A 113 min.

    97 min.

    132 max.

    200 min.

    234 max.

    4 cut-outs 32

    2 cut-outs 20

    4 cut-outs 25

    1 obround

    cut-out

    100 x 50

    84

    84

    190

    300

    270

    2 cut-outs 20

    s 12 module unit

    Back box fixing centres and cable entries (mm)

    4 cut-outs 32

    6 cut-outs 20

    4 cut-outs 25

    84

    84

    260

    372

    340

    120

    2 obround

    cut-outs

    100 x 50

    2 cut-outs 20

    s 16 module unit

    Back box fixing centres and cable entries (mm)

    Modules A (mm) B (mm)

    12 330 260

    16 402 260

    s Metal - flush mounting dimensions (mm)

    supply unitsIP 55

    6059 126059 19

    Pack Cat. Nos. Garage/outbuilding supply units

    1 6059 18 16 A and 6 A Type C MCB with40 A 30 mA DP RCD incomer

    1 6059 19 32 A and 6 A Type C MCB with40 A 30 mA DP RCD incomer

    Accessories

    1 0017 66 Lock and key1 0017 69 Wall brackets (set of 4)

    IP 55Box and cover in moulded materialTransparent, hinged, clip in to place coverLockable with keylock Cat. No. 0017 66

    Electric shower supply units

    1 6059 12 40 A 30 mA DP RCBO1 6059 13 50 A 30 mA DP RCBO

    90

    142

    30

    30

    120

    180

    115

    s Dimensions

    Cat. Nos. 6059 12/13/18/19

    View from

    sides

    View from

    below

    View from

    above

    View from

    sides

    View frombelow

    View from

    above

    198

  • 7/28/2019 Home Circuit Protection

    14/14

    voltage surge protectors

    s Protection against lightning effects

    Lightning directly or indirectly generates the following effects :

    thermal (blow-outs, fire) electrodynamic (loosening of terminals)

    rise in earth voltage (risk of electrocution) overvoltages of several thousand volts and destructive inducedcurrents (damage to electrical and electronic equipment, interruptionof operation)

    Protection against the effects of lightning is based essentially on :

    catching and discharging the current to earth the use of voltage surge protectors the passive protection of the installation

    Passive protection designates the part of the protection provided bythe structure and the configuration of the installation itself (neutralearthing system, area, level of equipotentiality, etc.)

    s Voltage surge protectors and regulation

    Voltage surge protectors allow :

    protection of sensitive devices against direct and indirect effects of

    lightning limitation of harmful consequences to people or livestock

    continuity of work

    1 - Product standards EN 61643-11 and IEC 61643-1Defines voltage surge protectors of two levels (types) :

    Type 1 Type 2 Type 3

    Type of wave 10/350 s 8/20 s 12/50 s - 8/20 s

    MainIn, Iimp In, Imax Uoc

    characteristics

    2 - Installation standards : IEC 60364 (or equivalent electricnational standards)The use of VSPs is recommended in new or renovated buildings in thefollowing cases :

    buildings equipped with lightning conductors : type 1 VSPswith Iimp 125 kA

    The use of VSPs is also strongly recommended in mountain areas,close to bodies of water or tall structures (buildings, trees, etc.), in thecases of line end installations or installations located less than 50 mfrom buildings equipped with lightning conductors.When VSPs are present on the power circuit, it is strongly advised toinstall a VSP on the communication circuits (telephone or data lines)

    s Types of lightning strikes

    Direct strike

    Overvoltages on power supply lines

    Overvoltages due to strikes in directproximity of building