12

HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

Embed Size (px)

Citation preview

Page 1: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted
Page 2: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

 

HoldTight®102 SALT REMOVER / FLASH RUST PREVENTER  

DESCRIPTION 

HoldTight®102 salt remover / flash rust preventer  is a one step additive that prevents flash rusting of wet abrasive and water‐blasted iron and steel surfaces and of dry‐blasted surfaces when used in a pressurized wash down.   It effectively removes all  salts,  including chlorides,  sulfates, phosphates, nitrates, and other contaminants,  including oil,  grease, and blast residues.  HoldTight®102 is expressly approved by most major coatings suppliers for use with most coatings.    

FEATURES  BENEFITS 

Provides Corrosion‐Free Surface For Up To 48 Hours   Allows Delay In Coating Pressure Washed/Blasted Steel 

Removes All Soluble Surface Salts  Clean Surface Assures Coating Adhesion 

Water Soluble  Wide Application in All Types of Washing/Blasting Processes 

Application Ratios of water to: 102 between 25:1 to 250:1   Economical To Use 

Leaves No Residue  Does Not Interfere With Subsequent Coatings 

Phosphate and Acid Free  Non‐Polluting and Safe To Use 

Biodegradable  Environmentally Friendly 

Non‐Flammable  Safe For Workplace  

Non‐Toxic  Safe For Applicators & Environment (see SDS for specifics) 

INDUSTRIAL/MARINE AND OFFSHORE APPLICATIONS 

Use HoldTight®102 salt remover / flash rust preventer 

during wet abrasive blasting and water jetting of new and old steel prior to coating 

during pressurized wash down after abrasive or water blasting new and old steel prior to coating 

in the final fresh water rinse when high‐pressure washing structures, decks, and bulkheads prior to touch‐up painting. 

as an additive to prevent flash rusting during hydrotesting heat exchangers and boilers  

HOW TO USE 

HoldTight®102 is added to the wet blast or wash down water at several common dilution ratios: 100:1 (water: 102) is typical where contamination is light, and humidity is low.  A dilution ratio of 50:1 may be needed where conditions are more severe (high chlorides, high humidity, highly contaminated substrates).   

HoldTight®102 is added to wet blasting as well as wash down cycles provided the water used does not contain high levels of contamination (chlorides, calcium carbonates, iron or other salts).   

A suggested dilution chart is available below for quick reference.  Where practical, test various dilutions first before proceeding with major work.  The “fail‐safe” level for blasting and wash down is 50:1. “Cycles” refer to blast/high pressure wash and wash down.  Avoid using hard water and allowing the wash water to ‘pool’ on flat surfaces. The calcium carbonate in very hard water may reduce the effectiveness of HoldTight®102.  Blow off excess water with dry, oil‐free compressed air.   

After the final wash down or rinsing using HoldTight, depending upon conditions & time (typically 48 hours) flash rust may appear. When re‐washing the surface to remove the flash rust with HoldTight, the solution pressure must be high enough to remove any flash rust.   

Once diluted, 102 will remain in solution indefinitely.  Always keep the solution covered  

WAIT TIME BEFORE COATING  

We recommend priming as soon as possible after the wash down cycle when the surface is dry and before flash rust appears.  It is the proper practice to apply primers only on dry surfaces. When using HoldTight®102 the typical “window” before coating begins is about 48 hours, although under favorable conditions (moderate temperature, low humidity, no rain, clean water used in the treated solution) this may be stretched out even further or if unfavourable reduce this “window”.  

PHYSICAL PROPERTIES 

Appearance: Colorless liquid pH 10.2

Specific Gravity: 1.0217 Flash Point: >210°C (>400°F)

Freeze Point -5°C (23°F) Viscosity 13 CPS

Solubility in Water 100%

Page 3: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

DILUTION CHARTS 

Wet Abrasive Blasting 

Application Dilution Ratio Blast Cycle – Normal 50 to100:1 Blast Cycle – High Humidity or Contaminated Substrate 50:1 Blast Cycle – Pressure Less Than 500 psi/34 bar 50:1 Wash Down Cycle – Normal 50 to100:1 Wash Down Cycle – Pressure 500 psi/34 bar (no flash rust) 50:1 Wash Down Cycle – Pressure 3000 psi/207 bar 100:1 Degreasing During Wash Down Cycle – Light Deposits 50:1 Degreasing During Wash Down Cycle – Heavy Deposits 25:1

 

UHP Water Jetting 

Application  Dilution Ratio Blast Cycle – preferred for best results – only if the Pump Manufacturer approves using HoldTight in the jetting water  

50 to 250:1 

Wash Down Cycle – If HoldTight 102 Used In Blast Cycle  50 to 200:1 

Wash Down Cycle ‐ >500 Psi/34 Bar – 8 L/min (2 gal/min)  50 to 100:1 

Wash Down Cycle – Hard Water or Highly Contaminated Substrate or Deeply Pitted Surface Profile   

50:1 

 

Dry Blasting 

Application  Dilution Ratio Wash Down Cycle ‐ >500 Psi / 34 Bar at 8 L/min (2 Gal/min)  50:1 

Wash Down Cycle – 1500 Psi / 102 Bar (Recommended)   50:1 to 100:1  

Other Applications 

Application  Dilution Ratio HP Washing – Prior To Re‐Coating Decks and Bulkheads  50 to 100:1 

Hydrotest Water For Testing Pressure Vessels  50 to 100:1 

HoldTight® 102 Technical Facts  

VOC’s?  

In HoldTight®102 as per the SDS, VOC’s were Not Detected. (ND on the SDS which means "None Detected" or "Not Detected")   

Water quality?  

HoldTight® recommends using potable water to dilute HoldTight®102. If potable water is not available and other water is used, then the recommended maximum contaminant levels for Total Hardness and, Chlorides and pH are listed below:  

1. Total Hardness < 120 ppm (7 grains per gallon) 2. Chlorides < 200 ppm 3. pH 6.5 – 7.5  

Before dilution with HoldTight®102, water treatment can be used to regulate the levels. Various ion exchange resin units are available to soften the water. Reverse osmosis processes can also be used to treat the water along with other methods of desalination which will regulate the pH and chloride levels. Some commonly used water treatment devices are available from Culligan and US Water Filter, which can be delivered to the jobsite and installed directly in‐line before the dilution step.  

Dilution Ratios  

HoldTight®102 dilution ratios have nothing to do with the type of substrate.  

Lowest Dilution Limit? Increasing the concentration of HoldTight®102 will only be effective to its saturation point (25:1) where it will combat the high level chlorides. At concentrations above the saturation point, increasing the concentration will not help, but may slow down the evaporation of excessive HoldTight®102 on the surface.  

Substrate  

HoldTight®102 can be used on most substrates with the exception of wood.  

Page 4: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

Cleaning & Salt* Removal with Hand/Power Tools & Hand Washing  

 

1.  Remove all “crud” ‐‐ loose coating, rust, mineral scale, visible contaminants, road salts, etc. – by dry or wet abrasive blasting, water jetting or other forms mechanical removal such as power tools or hand held tool cleaning. 

2.  Dilute HoldTight®102 with 25 to 50 parts of potable** water to one part HoldTight®102 (25:1 to 50:1) OR simply add 3 to 6 oz. of HoldTight®102 to each gallon of water (the higher concentrations for higher contaminant levels) 

3.  Scrub the surface vigorously with this solution and a stiff bristled brush, preferably nylon or Teflon. 4.  Rinse and flush the scrubbed area thoroughly with the same “102" solution, making sure that all visible “crud” is 

completely removed.  Use as much of the solution as practical.  If rinsing is impractical, wipe the surface to remove loose particles rust, coating, and other debris.  There is no need to rinse off HoldTight®102 with fresh water since the product leaves no residue and “fresh water” without “102" may add contaminants back on to the surface. 

5.  Dry the surface.  If evaporation is too slow, use clean, dry compressed air to blow the surface dry.  CAUTION:  Do not use compressed air if it is not clean and dry:  Any oil contamination or wetness re‐deposited on the surface by the drying process may cause rust to form and may re‐create one of the problems HoldTight®102 is used to solve. 

6.  If specification calls for salt removal, test the surface by any of the following procedures described in SSPC‐TU 4, Field Methods for Retrieval and Analysis of Soluble Salts on Substrates: Bresle patch, Kitigawa tube, qualitative ferrous ion, or Quantab strip.  That document describes several other tests, but we recommend these four based on our lab and field experience.  Call our Technical Services staff for assistance. 

7.  If tested contamination level is unacceptable, repeat steps 3 through 7.  If possible, more vigorously scrub and more thoroughly rinse the surface.  Review compressed air quality, if applicable.  HoldTight®102 concentration may also be increased (e.g., to 20:1), but drying time will also increase, and surface must be dry before primer or coating is applied. 

This application is appropriate only if pressure washing is physically or economically impractical.  It will be used most frequently when spot removal of loose coating, rust, visible contaminants, road salts, or other surface contaminants usually followed by spot priming, is acceptable to the specifications and coating vendor.    

*“Salts” include chlorides, sulphates, nitrates and phosphates. **Potable water that is very high in chlorides and/or carbonates may interfere with the performance of HoldTight®102  

“Coverage” & HoldTight® 102  

HoldTight®102 is not a coating.  It performs its two principal functions – salt removal and flash rust prevention ‐ as an adjunct to and enhancement of pressure washing with water (and/or wet abrasive blasting, or “wet jet” blasting, or “water jetting”).  Thus,  the  question  “How much  ‘102’ must  I  apply  to  a  given  area?”  is  irrelevant.    The  relevant  question  is,  “How much HoldTight®102 will  I  use when  I  blast  and/or  pressure wash  a  specific  area,  given  the  equipment  I  am using  (specifically, water consumption in a given amount of time) and the “production rate” (specifically, how much surface area do I cover in a given  amount  of  time)?”    The  answer  to  that  question  determines  how much  of  the  product  will  be  required.  In  short: determine  how much  water  you  will  use  based  on  flow  rate,  production  rate,  and  the  surface  area,  then  divide  by  the dilution ratio you have chosen:  50, 100, etc.  (Different flow and production rates will apply, of course, when water is used as part of  the stripping process  in wet‐abrasive blasting.  In such cases 102 must be used both  in  the stripping or removal operation and in the wash down operation.)  

With regard to washing down surfaces after dry or wet‐abrasive blasting: We know from experience that 102‐treated water applied at flow rates of less than 1 GPM under less than 500 psi at the surface is not sufficient to remove all abrasive dust, shattered corrosion products, and tiny paint particles, even when the surface has been “blown” clean with air only. (In fact, “blowing”  a  surface  clean  of  dust  generated  by  the  abrasive  blasting  operation  may  result  in  adding  oil  or  water contaminants to the surface from the compressor.)  When such contaminants remain on the surface, flash rusting will occur.  

We also know from experience that the cleanest surfaces are achieved with HoldTight®102 treated water at 3,000 psi with a flow rate of 2‐3 GPM.  In most cases 2 GPM, at 1,500 psi will be sufficient.  At these recommended flow rates and pressures, operator productivity is simply not a critical factor. The water flow and pressure, NOT the “dwell time”, are the determining factors  and most  important  variable  so  long  as  the water  is  treated with HoldTight®102.  If  the  operator,  in  those  cases, moves  the  wash  wand  or  tip  very  quickly  over  the  entire  targeted  surface,  he  will  use  less  HoldTight®102  without jeopardizing  surface  cleanliness.    If  he moves  slowly,  he  will  use more HoldTight®102,  but  will  achieve  the  same  result.  Based on experience reported to us by many customers, these pressure washing operations typically “clean” 500 to 1,000 square  feet  per  hour.    (Production  rate  is  of  course  a  function  of  operator  skill  and  strength,  surface  flatness  vs.  surface irregularities, and constraints imposed by positioning equipment, scaffolding, lifts, etc.)   

If the water does not contain HoldTight®102  in the recommended ratio the surfaces will flash.    If the water is significantly substandard (in terms of chlorides or other contaminants such as carbonates [hardness]) as discussed in our literature on the subject,  the  surfaces  might  flash  or  turn  even  with  102  (or,  for  that  matter,  any  additive  that  purports  to  remove contaminants).  In  such  cases,  either  increasing  the 102  to water  ratio  or  pre‐treating  the water,  or  some combination of both, will be necessary. 

Page 5: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

Manufacturer: HoldTight Solutions P.O. Box 27907 Houston, TX 77227.7907, Ph# 800.319.8802 / 713.266.9339,  

Fax# 800.728.8861 / 713.266.1022 Email [email protected] Web:  www.holdtight.com 

  

“CONCRETE” & HoldTight® 102  

Cleans concrete as well as steel – leaves no contaminants or residue in either case 

HoldTight®102 removes salts and all other visible and non‐visible contaminants and prevents flash rust on metal surfaces. It  is as effective on concrete as  it  is on metal surfaces  for cleaning. Added to water and applied under pressure,  it will remove both visible (oil, grease, crud etc.) and non‐visible (chlorides, phosphates, sulphates, nitrates etc.) contaminants from virtually any surface. 

Compresses a two‐step process (cleaning and rinsing) into one In concrete decontamination applications, acids, emulsifiers or other cleaning agents are typically used, but the surface must then be neutralized (and attain normal pH) before it is coated. Normal pH is achieved either by rinsing or pressure washing  the  surface  with  fresh  water.  Unlike  these  conventional  cleaning  agents  HoldTight®102  does  not  leave  any residue or film on the surface, which may  interfere with coating adhesion, and  it  leaves the surface with a normal pH, which  is necessary for optimal coating performance.  It evaporates rapidly after application,  leaving the surface dry and free of contaminants.   

Tested and/or approved by most coating manufacturers Surfaces treated with HoldTight®102 need no additional rinsing or washing. Using this product to remove contaminants from  concrete  surfaces  provides  superior  surface  preparation  and  improves  coating  adhesion.    Because  of  these properties,  literally  thousands  of  tests,  and  more  than  a  decade  of  field  experience,  HoldTight®102  is  approved  by virtually  every  coating manufacturer  for  use with  virtually  every  coating,  including  Carboline, Dampney, Hempel,  PPG, Sherwin‐Williams, Sigma, Tnemec, Wasser, Tristar and many others.  

Simple to use & Minimal waste Depending on the condition of the surface and pressure being used, dilute HoldTight®102 with potable water between 25:1 and 100:1 (25 to 100 parts water to one part HoldTight®102) and wash the surface with this solution using a pressure washer with a minimum of 2500 psi or more.    

“Disposal” & HoldTight® 102 

A number of studies of the proprietary compound that is the active ingredient in HoldTight® 102 salt remover / flash rust preventer have concluded that the material may be safely disposed of in sanitary sewers, rivers, lakes, and other bodies of water without endangering aquatic life or otherwise compromising the environment.  This was true even when that compound was tested at a much higher level of concentration than in HoldTight® 102 off‐the‐shelf and dramatically higher concentrations than in the product as applied.  The concentration of the compound in these studies was greater by a factor of 3 or 4 than its concentration in undiluted (“or neat off‐the‐shelf”) HoldTight® 102, and 150 to almost 1,000 times greater than in HoldTight® 102 when it is used in ANY application.  Even in these substantially higher concentrations, there were no measurable adverse effects.  

This chart relates necessary dilutions of HoldTight® 102 at various levels to the resulting concentration of this proprietary ingredient:  

Recommended dilution of HoldTight® 102  (by potable water) when used in various applications 

Concentration of proprietary compounds in HoldTight®102 at these dilution levels 

250:1  0.08% to 0.144% 

200:1  0.10% to  0.18% 

100:1  0.20% to 0.36% 

50:1  0.40% to 0.72% 

25:1  .80%   to 1.44% 

*25:1 is the lowest dilution of HoldTight® 102, and therefore the highest permissible concentration of the proprietary compound in ANY application. For disposal instructions please read the SDS.  

PACKAGING

HoldTight®102 Order Code: 1USG HT102g, 19 liter (5 USG) HT102p, 208 liter (55 USG) HT102d, 1000 liter (275USG) HT102t

This information is, to the best of our knowledge, correct at the date of the printing. Always consult HoldTight Solutions Inc., for the latest changes. Since the conditions of application and service, including equipment used, are beyond our control, we accept no liability on the basis of the information and suggestions here or elsewhere. Please refer to the Material Safety Data Sheet for handling and storage information

 

Page 6: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

HoldTight®102   

09.21.2015                                                                                                                                                                    Page 1 of 7  

Safety Data Sheet Conforms to OSHA CFR 29 1910.1200 and aligns to the United Nations Globally Harmonized

System Conforms to The United Nations Regulation Globally Harmonized System Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II – Europe

Conforms to Regulation (EC) No 1272/2008 and aligns to the United Nations Globally Harmonized System

1.1 Product Name: HoldTight®102 1.2 Producer: HoldTight Solutions Inc.

P.O. 27907, Houston, TX 77227.7907, 713.266.9339 / 800.319.8802

1.3 Product Use: Salt Remover / Flash Rust Preventer 1.4 Emergency Telephone Number: Hazmat Service 800-373-7542 1.5 Canada Emergency Telephone number (613) 996-6666 1.6 International Shipments Emergency Telephone Number +1-484-951-2432

GHS HAZARD 2.1 Hazard Classes Hazard Categories Eye irritation Category 2A Skin irritation Category 3

2.2 Signal Word: Warning

2.3 Pictograms:

2.4 Hazard Statements:

PHYSICAL HAZARDS: None HEALTH HAZARDS: H316: Causes mild skin irritation H319: Causes serious eye irritation

ENVIRONMENTAL HAZARDS: None

PRECAUTIONARY STATEMENTS: P261: Avoid breathing mist or vapors P264: Wash skin thoroughly after handling P273: Avoid release to the environment P280: Wear protective gloves and eye protection

Section 1 - Chemical Product and Company Identification

Section 2 - Hazards Identification

Page 7: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

HoldTight®102   

09.21.2015                                                                                                                                                                    Page 2 of 7  

RESPONSE STATEMENTS: P301 +310+ P331: IF SWALLOWED: USA Immediately. Call the National POISON CENTER at 800-222-1222.

OUTSIDE USA Immediately call poison center or doctor. DO NOT induce vomiting P303+P361+353: IF ON SKIN, Take off all contaminated clothing immediately. Rinse skin with water/shower P304+340: IF INHALED, Remove to fresh air and keep comfortable for breathing. If not breathing give artificial respiration. DO NOT use mouth to mouth resuscitation without proper protection

P305+P351: IF IN EYES rinse cautiously with water for at least 15 minutes P306+P361: IF ON CLOTHING, Take off contaminated clothing P376: Stop leaks if safe to do so. See section 6 for proper clean up

STORAGE STATEMENTS: P403 + P233: Store in a well-ventilated place, Keep container tightly closed when not in use

DISPOSAL STATEMENTS: P501: Dispose of content and/ container in accordance with local, regional, national and/or international regulation

Chemical Name CAS# EINECS # Concentration % Other Identifiers Tri(hydroxyethyl)amine 102-71-6 203-049-8 20-30% 2,2′,2″-3-hydroxy-triethylamine

1,2-propanediol

57-55-6 200-338-0 Trace to 2% 1,2-DIHYDROXYPROPANE

1,2-dihydroxypropane 110-91-8 203-815-1 Trace to 2% 1-oxa-4-azazcyclohexan,

WATER 7732-18-5 231-791-2 70-80 2,2',2''-nitrilotriethanol acetate

14806-72-5 238-874-2 Trace to 2% Ethanol, 2,2',2''-nitrilotris acetate

Eyes In case of eye contact, rinse with plenty of water and seek medical attention. Inhalation Move casualty to fresh air and keep at rest. If breathing is difficult, give oxygen. If not

breathing, give artificial respiration. Get medical attention. Skin Immediately flush with plenty of water for at least 15 minutes while removing contaminated

clothing and wash using soap. Get medical attention. Ingestion Do Not Induce Vomiting! Never give anything by mouth to an unconscious person. If

conscious, wash out mouth with water. Get medical attention.

Suitable (and unsuitable) extinguishing media

Product classified as Class IIIB may be flammable at high temperatures. Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Use appropriate media for adjacent fire. Cool unopened containers with water.

Special protective equipment and precautions for firefighters

Wear self-contained, approved breathing apparatus and full protective clothing, including eye protection and boots.

Specific hazards arising from the chemical

Emits toxic fumes (carbon oxides, nitrogen oxides) under fire conditions. (See also Stability and Reactivity section).

Section 3 - Composition / Information on Ingredients

Section 4 - First Aid Measures

Section 5 - Fire-Fighting Measures

Page 8: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

HoldTight®102   

09.21.2015                                                                                                                                                                    Page 3 of 7  

Personal precautions, protective equipment and emergency procedures

See section 8 for recommendations on the use of personal protective equipment.

Environmental precautions Prevent spillage from entering drains. Any release to the environment may be subject to federal/national or local reporting requirements.

Methods and materials for containment and cleaning up

Neutralize spill. Absorb spill with noncombustible absorbent material, then place in a suitable container for disposal. Clean surfaces thoroughly with water to remove residual contamination. Dispose of all waste and cleanup materials in accordance with regulations.

Precautions for safe handling See section 8 for recommendations on the use of personal protective equipment. Use with adequate ventilation. Wash thoroughly after using. Keep container closed when not in use. Avoid formation of aerosols.

Conditions for safe storage, including any incompatibilities Store in cool, dry well ventilated area. Hygroscopic material. Keep away from incompatible materials (see section 10 for incompatibilities).

8.1

Chemical Names ACGIH- TLV OSHA - PEL HoldTight 102 25 mg/m3 TWA 25 mg/m3 TWA

8.2 ACGIH® = American Conference of Governmental Industrial Hygienists. TLV® = Threshold Limit Value. OSHA = US Occupational Safety and Health Administration. PEL = Permissible Exposure Limits.

 

NOTE: TWA Means "TWA is the employee's average airborne exposure in any 8-hour work shift of a 40-hour work week which shall not be exceeded."

8.3 Ventilation: Provide general or local exhaust ventilation systems to maintain airborne concentrations below TLV/PELs Local exhaust ventilation is preferred because it prevents contaminant dispersion into the work area by controlling it at its source.

8.4 Personal protective equipment

8.4.1 Respiratory protection respirator Respiratory protection not required. For nuisance exposures use type OV/AG (US) or type ABEK (EU EN 14387) Respirator cartridges

8.4.2 Hand protection Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique to avoid skin contact with this product. Dispose of contaminated gloves after use. Select gloves tested to the ANSI/ISEA 105-2011 Full contact: Nitrile rubber Splash contact: Nitrile rubber

8.4.3 Eye protection Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US).

8.4.4 Skin and body protection Chemical splash protecting against chemicals, the type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Section 6 - Accidental Release Measures

Section 7 - Handling and Storage

Section 8 - Exposure Controls / Personal Protection

Page 9: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

HoldTight®102   

09.21.2015                                                                                                                                                                    Page 4 of 7  

8.5 Protective Clothing Pictograms

9.1 Appearance: Clear Odor: Odorless Boiling Point: 212 °F 100 °C Melting / Freezing Point: 23°F / -5°C Relative Density (water = 1): 1.01 Solubility in Water: 100% pH: 10.2 Specific Gravity: 1.0217 Viscosity: 13 CPS Vapor Pressure: 0 kPa @ 20°C Flash Point: 400 °F 204 °C Lower Explosive Limit: Not Available Upper Explosive Limit: Not Available

Solubility: Easily soluble in cold water, hot water. Soluble in methanol, acetone.

Very slightly soluble in diethyl ether, n-octanol.

Chemical stability The product is stable. Possibility of hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Hazardous polymerization Under normal conditions of storage and use, hazardous polymerization will not occur.

Conditions to avoid Excessive Heat Hazardous decomposition products

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

11.1 Toxicity Data

Chemical Name     

HoldTight‐102  LD50 [oral rat]  6400 mg/kg 

HoldTight‐102  LC50 [dermal rat]   22500 mg/kg 

HoldTight‐102  LC50‐ [oral rabbit]  11,000 mg/kg 

HoldTight‐102  LC 50‐oral [guinea pig]   11,000 mg/kg 

11.2 Carcinogenicity:

IARC 3-Group 3: Not classifiable as to its carcinogenicity to humans (Triethanolamine). ACGIH No components of this product present at levels greater than or equal to 0.1% is identified as a

carcinogen or potential carcinogen by ACGIH. NTP No components of this product present at levels greater than or equal to 0.1% is identified as a

known or anticipated carcinogen by NTP. OSHA No components of this product present at levels greater than or equal to 0.1% is identified as a

carcinogen or potential carcinogen by OSHA.

Section 9 - Physical and Chemical Properties

Section 10 - Stability and Reactivity

Section 11- Toxicological Information

Page 10: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

HoldTight®102   

09.21.2015                                                                                                                                                                    Page 5 of 7  

11.3 Key to Abbreviations IARC = International Agency for Research on Cancer. ACGIH= American Conference of Governmental Industrial Hygienists NTP = National Toxicology Program.

11.4 Signs & Symptoms of Exposure Skin Irritation, redness, itchiness. Eyes Irritation, redness, watering eyes, itchiness. Respiratory Irritation, coughing, wheezing. Ingestion Irritation, nausea, vomiting, diarrhea.

Chronic Toxicity Not Available Teratogenicity Not Available Mutagenicity Not Available Embryo toxicity Not Available Specific Target Organ Toxicity Not Available Reproductive Toxicity Not Available Respiratory/Skin Sensitization Not Available

Aquatic vertebrates LC50 11800 mg/l Fish 96 hours Aquatic invertebrates EC50 610mg/l Daphnia 48 hours

Persistence and Degradability Result: 96 % - Readily biodegradable. Bio accumulative Potential Not Available Mobility in Soil Not Available PBT and vPvB Assessment Not Available Other Adverse Effects Not Available

Waste Residues Users should review their operations in terms of the applicable federal/national or local regulations and consult with appropriate regulatory agencies if necessary before disposing of waste product container.

Product Containers

Users should review their operations in terms of the applicable federal/national or local regulations and consult with appropriate regulatory agencies if necessary before disposing of waste product container.

The information offered in section 13 is for the product as shipped. Use and/or alterations to the product may significantly change the characteristics of the material and alter the waste classification and proper disposal methods.

14.1 US DOT Not Dangerous Goods TDG Not Dangerous Goods IMDG Not Dangerous Goods Marine Pollutant No IATA/ICAO Not Dangerous Goods

Section 12 - Ecological Information

Section 13 - Disposal Considerations

Section 14 - Transport Information

Page 11: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

HoldTight®102   

09.21.2015                                                                                                                                                                    Page 6 of 7  

15.1 US Regulations:

TSCA: All components of this product are on the TSCA Inventory or are exempt from TSCA Inventory requirements under 40 CFR 720.30

CERCLA Hazardous Substances and corresponding RQs None

SARA Community Right-to-Know Program: None

Clean Water Act: None

Clean Air Act: None

OSHA: All ingredients are listed in 1910.1200

State Regulations California prop. 65: None

Chemicals on the following State Right to Know Lists:

Massachusetts: All components of this product are on the Massachusetts Inventory or are exempt from Inventory requirements.

New Jersey All components of this product are on the New Jersey inventory or are exempt from Inventory requirements.

Pennsylvania: All components of this product are on the Pennsylvania Inventory or are exempt from Inventory requirements.

15.2 Canadian Regulation: All substances contained in this product are listed on the Canadian Domestic Substances List (DSL) or are not required to be listed. HoldTight 102 is registered with: CANUTEC Transport Dangerous Goods Directorate Transport Canada Ottawa, Ontario, Canada K1A 0N5 (613) 996-6666

15.3 Europe Regulations All substances contained in this product are listed on the EU directives or are not required to be listed.

15.4 International Regulations: Australian Inventory of Chemical Substance: All components of this product are on the Inventory or are exempt from Inventory requirements.

National Existing Chemical Inventory in Taiwan: All components of this product) are on Inventory or are exempt from Inventory requirements.

Philippine Inventory of Chemicals and Chemical Substances All components of this product are on the Inventory or are exempt from Inventory requirements.

China Existing Chemical Inventory: All components of this product are on the Inventory or are exempt from Inventory requirements.

Section 15 - Regulatory Information

Page 12: HoldTight®102 - Industrial Coatings€¦ · HoldTight®102 salt remover / flash rust preventer is a one step additive that prevents flash rusting of wet abrasive and water‐blasted

HoldTight®102   

09.21.2015                                                                                                                                                                    Page 7 of 7  

16.1 Disclaimer: The information presented in this Safety Data Sheet is based on data believed to be accurate as of the date this Safety Data Sheet was prepared. HOWEVER NO responsibility is assumed for any damage or injury resulting from abnormal use or from any failure to adhere to recommended practices. The information provided above is furnished on the condition that the person receiving them shall make their own determination as to the suitability of the product for their particular purpose and on the condition that they assume the risk of their use.

16.2 References: CHEMpendium data base of Canadian Centre for Occupational Health and Safety (CCOHS), JJ Keller on Line, European Chemical Agency Data Base and MSDS and SDS of chemicals in this mixture.

16.3 SDS Preparation Date: 07/30/2015

 

16.4 Contact for questions, comments, further information:

 HoldTight Solutions Inc. PO Box 27907 Houston TX 77227 800 719 8802 (North America) +713 266 9339 (International) Fax +713 266 1022 [email protected] www.holdtight.com

 

 

Section 16 - Other Information