1/14
ATEX Manual 2667, version 7
ATEX ManualFor the intrinsically safe charge amplifier type 2667 - all variants
Content:
Product data sheet
Mounting details with typical loop (*)Declaration of Conformity
ATEX certificate
Notice to request the ATEX manual in other EU languages
(*) for installation with devices from other manufacturers than Brel & Kjr Vibro, please read the
appropriate manuals or contact the manufacturer of your device for installation instructions.
Customer responsibility
The customer is solely responsible for the correct layout of the electric system with regard to theapplicable explosion protection regulations as well as for the correct operation of the product. Theexplosion protection- and safety regulations have to be observed and if necessary verified by anexpert.
In case the system is installed by a sub-contractor on behalf of the customer, the product must not beput into operation until the sub-contractor has proven that the system has been installed correctly andconforms to the valid regulations by means of an installation certificate.
The customer also has to notify the notified body about the installation and operation of explosion-protected systems as well as of any substantial changes or maintenance work done to the installation.
2667 ATEX Manual v. 7_2010 Page 1 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
2/14
Charge Amplifier type 2667 data sheet
1. Application
Charge Amplifier: Certified Intrinsically Safe to foruse in hazardous areas.
II 3GEx ic IIC T6
2. UsageType 2667 is intended for connection to charge type accelerometers in areaswith potential risk of explosions, when monitoring plant machinery in harshenvironments, for industrial machine installations and for gas turbineapplications requiring long mean time between failures.
The type 2667 has a differential input which improves the signal/noise ratioin strong electromagnetic fields when used together with balancedaccelerometers, such as B&K Vibro Type 5704.
To protect the Type 2667 from harsh environmental conditions, such ashumidity and vibration, it should be mounted in a junction box in conformitywith IP 65, as available from Brel & Kjr Vibro.
Type 2667 is available in a number of versions when other amplificationfactors or filtering ranges are required.
3. Technical DataBalanced Charge Input
Sensitivity: ..................................................................... 1 mV/pC, 2% - 80 HzFrequency range: ...................................................... 1 Hz to 100 kHz 0.5 dBMaximum input signal: ............................................................................... 8 nCHigh-pass filter: ...................................................... 2
ndorder, -3 dB @ 0.48 Hz
Common mode rejection: .......................................... > 30 dB (1 Hz to 50 kHz)Noise: < 40 x 10
-3pC referred to input terminated with 14 nF, 2 Hz to 50kHz
Source impedance: ............................................................................... >50MEffects of Source Impedance on Low Frequency Response:
10 M2 dB peak @ 0.8 Hz
4 M5 dB peak @ 0.8 Hz
2 M8 dB peak @ 0.9 HzConnections: ........................................................................... Screw terminalsMaximum wire gauge: ......................................................................... 1.5 mm
2
OutputMinimum voltage deviation: .......................................... -2 V to -18 V unloadedDC offset: ................................................................................................ - 10 V
Output impedance: ................................................................................ 2 x 5 Short circuit time: .................................................................................... InfiniteDrive capacity: ....................................................................... Min. 13 mA peakConnections: ........................................................................... Screw terminals
2667 ATEX Manual v. 7_2010 Page 2 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
3/14
EnvironmentalIntrinsically Safe Certification: ........................................................ Ex ic IIC T6Temperature:Operating temperature: .................................. -40 to +70C (-40F to +158F)Non-Operating Temperature: .................... -55C tp +100C (-67F to +212F)Humidity: ................................................................................. +30C, 95% RH
Electromagnetic sensitivity: ........................................................< 0.15 V/A/mEnclosure: ...................................................................... Protection class IP20
Power SupplyVoltage supply: ...............................................................................- 24 V 4 VQuiescent Current consumption: .............................. < 7.4 mA (typically 5 mA)Incorrect installation:
Connections to the output and supply terminals can be arbitrarilyswitched around without over-loading the preamplifier.
PhysicalHeight: ................................................................................... 41 mm (1.614 in)Width: .................................................................................... 41 mm (1.614 in)Length:................................................................................... 83 mm (3.268 in)Weight: ................................................................................... 185 g (0.716 lb)
Electrical layout
EMC
EN61326-1:2006To avoid possible negative influences caused by a surge impulse (accordingto EN61000-4-5), cable EL3006 or AC-900 between 2667 and barrier mustbe used.
Note:All values are typical at 250C (77
0F), unless measurement
uncertainty is specified. All uncertainty values are specified at 2
(i.e.expanded uncertainty using a coverage factor of 2).
BIAS
T7
8
9
10T
1 T
2
3
4
5
6
T
HI
LO
-24V
0V
4. Special conditions for safe use The terminals 1-6 of the apparatus shall be connected to certified
barriers or isolators located in the non hazardous area.
It is recommended that the Charge Amplifier is mounted in accordancewith the Principle Diagram for Intrinsic Safe Monitoring System, Brel &
Kjr drawing no. EW2013 dated 1998-05-26, or Brel & Kjr drawingno. EW2753 rev. B dated 05.05.2008.
The Charge Amplifier shall be mounted in a junction box connected toprotective earth.
2667 ATEX Manual v. 7_2010 Page 3 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
4/14
The blue chassis and the four screws at the buttom of the amplifier areconnected to the IS circuit terminal 1,4,7 and 10. The DIN rail springclamp is isolated from the IS circuit of the amplifier.
5. Intrinsically safe specifications
Input terminals 7 10:
Input, terminals 8-9 to (7,10)
Ui: ...................................................................................................... -24 VIi: ...................................................................................................... 1 mA
Li: ..................................................................................................... 75 HCi: ........................................................................................................ 5 nFPi: ...................................................................................................... 5 mW
Uo: .......................................................................................................... 0 VIo: ....................................................................................................... 0 mALo: ....................................................................................................... 1 mHCo: ..................................................................................................... 100nF(maximum cable capacity between terminal 8,9 and 7,10)Po: ...................................................................................................... 0 mW
Output terminals 1 6:
Output HI, terminals 2 to (1,4)Ui: ....................................................................................................... -28 VIi: ..................................................................................................... 52 mAPi: .................................................................................................. 300 mWCi: ..................................................................................................... 5,5 nF
Li: . ................................................................................................. 75 H
Output LO, terminals 3 to (1,4)Ui: ....................................................................................................... -28VIi: ..................................................................................................... 10 mAPi: .................................................................................................... 30 mWLi: .................................................................................................. 0,05 mHCi: ................................................................................................... 0,05 nF
Supply 24V, terminals 5 to (1,4)Ui: ....................................................................................................... -28VIi: ..................................................................................................... 95 mAPi: .................................................................................................. 700 mW
Li: ...................................................................................................... 75 HCi: ..................................................................................................... 5,5 nF
Ambient temperature:-40C to +70C
Appl ied standards:EN 60079-0:2009
EN 60079-11:2007
EC Type examination certifi cate:ITS09ATEX26834X
2667 ATEX Manual v. 7_2010 Page 4 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
5/14
6. Connection The preamplifier must be mounted in a shielded Ex junction box via DIN-rail.Guidelines for connecting transducers to Charge Amplifier type 2667 seeoverleaf.
Note: It may be advantageous to use Microdot Input Adaptor type EQ2353for connection of single-end accelerometers.
Connection to a differential accelerometer:
The figure shows the Type 2667 with connected cable(s).
7. VersionsType 2667 may be delivered in several versions.
Standard version in bold.
Type number Sensitiv ity Filter Power Supply
2667-S-0-001-104 1mV/pC 1Hz-100kHz -24V
2667-S-0-025-104 1mV/pC 25Hz 100kHz -24V
2667-S-1-025-053 10mV/pC 25Hz 5kHz -24V
2667-S-1-025-104 10mV/pC 25Hz 100kHz -24V
Further information can be found in the specific technical information foreach type number.
2667 ATEX Manual v. 7_2010 Page 5 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
6/14
Principle Diagram for Intrinsic Safe Monitoring System, Brel & Kjr drawing no. EW2013 dated 1992-08-24,revised 1998-05-26
2667 ATEX Manual v. 7_2010 Page 6 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
7/14
Data sheetCharge Amplifier type 2667
2667 - rev 7
chassisviacablegland
CableArmourconnectedto
JunctionBox
1
T
T
+-T
5
-24V
0V
6
HI T
LO
3 42
Type
2667
-24V
COM TT
SIG
TT
COM
-24V
SIG
TerminalRow
HazardousArea
SafeArea
ISBar
PEBar
VibrationMonito
r
TT
TT
T
T
Ins
trumen
tation
Ca
bine
t
SafetyB
arrier
CableArmourconnectedto
chassisviaPEbar/StrainRelief
Brel&KjrVibro
PEGroundConnection
1 2 3
1
1
2
3
3
IntrinsicallySafeEarth(IS)Connection
ProtectiveEarth(PE)Connection
Thisdraw
ing
belong
toB&KVibroan
dmu
stno
tbecop
iedw
ithoutperm
ission.
AB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
2
3
4
5
6
7
8
9
10
11
12
13
14
1
CDEFGHIJ
ABCDEFGHIJ
Title:
B&KVibroDrawingNo.-Rev.:
Skodsborgvej307B
DK-2850Nrum,Denmark
Phone:
Fax:
E-mail:
+4545802937
+4577412500
EW2753-A
TypicalLoop,AccelerometerType570
4-
ChargeAmplifierType2667-SafetyB
arrierTypeMTL7096-
Date
Rev.
Approved
B&KVibro
Checked
B&KVibro
B&KVibro
Prepared
Description
A
13
.07
.07
InitialIssue
JLS9670
CGO9670
BL9670
13.juli200714:06:13
Brel & Kjr Vibro A/S reserves the right to change specifications without notice
July 20102667 ATEX Manual v. 7_2010 Page 7 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
8/14
2667 ATEX Manual v. 7_2010 Page 8 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
9/14
2667 ATEX Manual v. 7_2010 Page 9 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
10/14
2667 ATEX Manual v. 7_2010 Page 10 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
11/14
2667 ATEX Manual v. 7_2010 Page 11 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
12/14
2667 ATEX Manual v. 7_2010 Page 12 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
13/14
Achtung !
Vor Inbetriebnahme des Produktes muss dieBetriebsanleitung gelesen und verstanden werden.
Bei Bedarf die Betriebsanleitung in fehlender EU-Sprache unter folgender Adresse anfordern:
Note!
Before operating the product the manual must beread and understood.
If necessary you may order the manual in themissing European Union language under thefollowing address:
ATTENTION !
Avant utilisation de l'appareil, il fautimprativement avoir lu et compris le manuel
d'emploi.Si besoin, commander le manuel d'emploi dans lalangue manquante l'adresse suivante :
Nota importante!
Antes de utilizar este producto debe leer ycomprender el manual.
Si necesita el manual en otro idioma de la UninEuropea, puede pedirlo en la siguiente direccin:
Nota !
Il manuale deve essere letto e compreso prima
della messa in servizio del prodotto.Se necessario, il manuale mancante nella linguaEuropea desiderata, ordinabile al seguenteindirizzo:
Ateno !
Antes de usar o produto necessrio ler adocumentao e entender-la.
Se for necessrio favor pedir a documentao nalngua europeia que necessita dirigindo-se a estdireo:
Attentie!
Voor ingebruikname van het produkt dient degebruiksaanwijzing gelezen en begrepen te zijn.
Bij behoefte aan een gebruiksaanwijzing in eenontbrekende EU-taal is deze op onderstaand adresaan te vragen:
Henvisning:
Fr produktets ibrugtagning skalbrugsanvisningen lses og forsts!
Brugsanvisningen kan bestilles p et EU-sprogved henvendelse til:
Observera !
Fre idrifttagning av produkten mstebruksanvisningen lsas och frsts.
Om ndvndigt kan bruksanvisningen bestllas idet saknade EU-sprket under fljande adress:
Huomio!
Ennen kyttnottoa tulee lukea ja ymmrtkyttohjeet.
Kun tarvitset kyttohjeita muilla EU-kielill otayhteys seuraavaan osoitteeseen:
!
, .
, :
Figyelem!
A termk zembe helyezse eltt az zemeltetsiutastst el kell olvasni, s meg kell rteni.
Szksg esetn hinyz EU-nyelven azzemeltetsi utastst, az albbi cmen lehetignyelni:
Uwaga!
Przed rozpoczciem uytkowania urzdzeniauprzejmie prosimy o uwane zapoznanie si zinstrukcjobsugi.
Instrukcje obsugi dla naszych urzdzedostpnes we wszystkich oficjalnych jzykach UniiEuropejskiej. Brakujce egzemplarze monazamawiapod wskazanym poniej adresem:
Pozor!
Ped uvedenm vrobku do provozu je nutnpest si nvod k provozu a porozumt mu.
V ppad poteby si nvod k provozu v chybjcei EU vydejte na nsledujc adrese:
Upozornenie !
Pred uvedenm zariadenia do prevdzky si trebadkladne pretaprevdzkov nvod a treba jehoobsah sprvne pochopi.
V prpade potreby si prevdzkov nvod vyiadajtev prslunom jazyku E na nasledovnej adrese:
Pozor!
Pred zagonom proizvoda morate najprej prebrati inrazumeti navodilo za uporabo.
Po potrebi zahtevajte navodilo za uporabo v jezikuEU, ki vam manjka, na naslednjem naslovu:
2667 ATEX Manual v. 7_2010 Page 13 of 14
8/11/2019 Hoja de Datos Amplificador de Carga_bruel&Kjaer Type 2667
14/14
Uzmanbu!
Pirms produkta ekspluatcijas uzskanas, rpgi
izlasiet lietoanas instrukciju.Vajadzbas gadjum pieprasiet lietoanasinstrukciju izstkstoajES valodpa du adresi:
Dmesio!
Prie pradedant naudoti produkt, atidiaiperskaitykite instrukcij.
Esant reikalui, reikalaukite instrukcijos trkstamaES kalba tokiu adresu:
Thelepanu!
Enne toote kasutuselevttu tuleb kasutusjuhendlbi lugeda ja sellest aru saada.
Kui vajate kasutusjuhendit mnes muus EL keeles,ksige seda jrgmiselt aadressilt:
Note!
Before operating the product the manual must beread and understood.
If necessary you may order the manual in themissing European Union language under thefollowing address:
Brel & Kjaer Vibro A/SSkodsborgvej 307B2850 NaerumDenmark
Phone: +45 7741 2500Fax: +45 4580 2937E-mail: [email protected]
Internet: www.bkvibro.com
2667 ATEX Manual v 7 2010 Page 14 of 14