Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
G
www.medacta.com
GMK® Revision Leaflet ref: 99.27.11US rev. 02
Hip Knee Spine Navigation
Brochure
D i f f e r eNt NeeDS . . . your g loba l So lut ioN
Medacta InternationalStrada Regina6874 Castel San Pietro - SwitzerlandPhone +41 91 696 60 60 - Fax + 41 91 696 60 66
Distributed by: Medacta USA 1556 West Carroll AvenueChicago Illinois 60607Phone +1 312 878 2381 - Fax +1 312 546 [email protected]
G K ®
R E V I S I O NGLOBAL MEDACTA KNEE
easy to use instrumentation allows accurate and straightforward procedures, adaptaBle to different surgical scenarios
micrometric adjustment of tibial resection level
• the tibial resection depth can be set without compromises, allowing maximum bone stock preservation
intuitive offset system • the surgical technique is simplified and the number of instruments is reduced
G K ®
R E V I S I O N i n s t r umen t sGLOBAL MEDACTA KNEE
accurate and straightforward joint line management
• cuts for femoral augments can be performed directly through the trial femoral component
• distal cutting block positioning can be micrometrically fine-tuned
d i f f e r e n t n e e d s . . . Y O U R g l o B a l s o l u t i o n
GLOBAL MEDACTA KNEE
complete, Versatile and accurate
360°
G K ®
P R I M A R YGLOBAL MEDACTA KNEE
G K ®
H I N G EGLOBAL MEDACTA KNEE
DISCOVER THE
OTHER MEMBER OF
THE GMK® FAMILY
same internal and articular femoral profiles as gmk® primary and gmk® hinge
freedom of choosing intraoperatively the most suitable solution
gmk® primary
gmk® revision
gmk® hinge
asymmetric CoCr mirror polished tibial tray
• reduced risk of overhanging
• reduced backside wear
• gmk® primary and gmk® revision tibial baseplates share the sizes and anatomic shape
360°-adjustable tibial and femoral offsets to maximize bone coverage without compromises
bone preserving femoral component • reduced box (even smaller than many primary implants
on the market!)[1]
• bone conserving ps box that functions with either the ps or semi-constrained tibial inserts
[1] data on file: medacta®
G K ®
R E V I S I O N i m p l a n t anatomic design of the trochlea to accommodate both natural and prosthetic patellae
inset and anatomic resurfacing patellae
for natural patellar tracking
tibial inserts
• multiple options of tibial bearings, uc, ps and semi-constrained
• semi-constrained tibial inserts available in thicknesses from 10 to 26 mm
tibial augmentations
screwed tibial spacers to address asymmetric bone defects
press fit cementless extension stem • the same stems can be used on tibia and femur
• 1 mm longitudinal ribs to increase rotational stability
• gmk® stems were designed to function in multiple applications from complex primarys
to use with the gmk® hinge
cemented and cementless extension stems complete range of diameters and lengths
femoral augmentations
distal and posterior spacers mechanically attached to femoral component