Upload
acmax
View
216
Download
2
Tags:
Embed Size (px)
DESCRIPTION
http://acmax.mx/images/pdf/CATALOGOS/HiokiFMI.pdf
Citation preview
www.hioki.com
DIG
ITA
L C
LAM
P T
ES
TE
RS
AC A
AC/DC
2
In
depe
nden
t-opening double-lever design
www.hioki.com
AC A› 42 to 1000 AC A› 4.2 to 600 AC V› 420m to 600 DC V› Continuity and Resistance
› 10 to 100 AC A and DC A (3287)› 100 to 1000 AC A and DC A (3288/3288-20)› 4.2 to 600 AC V› 420m to 600 DC V› Continuity and Resistance
3280-10 3280-20
3287 3288/3288-20
Ultra-thin 10mm clamp and compact body lets you get into even the narrowest spaces
No metal exposure to ensure safety
Advanced core technology eliminates magnetization-induced heat and noise, even in heavy-current
Single-handed switching
AC/DCAC/DC True RMS
AC True RMS
DROP
PROOF
Only 100 grams light
Ultra-thin 10mm clamp
AC
Please refer to page 6 for detailed specifications.
DROP
PROOF
AC/DC True RMS
DIG
ITA
L C
LAM
P T
ES
TE
RS
AC A
LEAK
3
LEAKHighly sensitive core provides up to 10uA of resolution
10.00 mA range for leakage testing (0.01 mA resolution)
Simply grip handles to power on
Tough and durable body built for long use
Resolution up to 10uA
Flip
cov
er
to re
ad display from
any angle
Super strong hinge resists tough handling
9mm thin clamp lets you get around the narrowest spaces
Analog Output
AC ASimply grip handles to power on
Super strong
LEAKLEAKHighly sensitive LEAKcore provides LEAKcore provides LEAKup to 10uA of resolution
durable body built for long
10.00 mA range for leakage testing (0.01 mA resolution)
Insulatedconductor
› 30 to 1000 AC A (3282)› 30 to 600 AC A (3281)› 300 to 600 AC V› Resistance and Frequency› Continuity
› Innovative Flip Design› View readings from any angle› 6 to 1000A (3291-50)› 30m to 1000A (3293-50)
› 10m to 200A› Frequency› Bar Graph
3288/3288-20 328332813282
3293-503291-50
AC True RMS + LEAKAGE
AC True RMS + LEAKAGE
AC True RMS
AC True RMS
AC True RMS CATIV 600V Safe
www.hioki.com
AC/DC
POWER
4
AC/DCAC/DCInrush Current
Peak HOLD
3285 with resistance range
DIG
ITA
L &
AN
ALO
G C
LAM
P T
ES
TE
RS
AC, DC, AC+DC
Analog OutputAC Adapter
Detachable clamp measurement system
Switch between 3 advanced clamp sensors
Up to 100 meter cable length available
Handheld Power Meter
Check for harmonics, power factor, etc.
High Performance for Single-phase
to balanced 3-Phase circuits
› 20 to 200 AC A/20 to 200 DC A (3284)› 200 to 2000 AC A/200 to 2000 DC A (3285 & 3285-20)› 30 to 600 AC V› 30 to 600 DC V› Frequency› Max/Min/Avg/RMS modes
› Super wide range according to clamp sensor› 20 to 2000 AC and DC A, up to 3000A Peak› Harmonics filter› Monitor and record demand and inrush current
› Output effective value, frequency & waveforms
3290-10:› Record integrated current, max/min/avg & duty
› Operating time/duty measurement› 20 to 1000 AC A› 150 to 600 AC V› 3kW to 1200kW› Frequency› Reactivity, phase angle
3284 3285
3286-20
3285-20
3290/3290-10AC/DC True RMS
AC/DC True RMS AC/DC True RMS
AC True RMS + Power
AC/DC True RMS
Please refer to pages 6-7 for detailed specifications.
POWER&
POWER QUALITY
5
POWER QUALITYQUALITY
Store data in 2GB SD Card
LAN and USB2.0
interfaces
PO
WE
R &
PO
WE
R Q
UA
LIT
Y T
ES
TIN
G
POWER› 1P2W to 3P4W› Monitor Inrush current, Voltage swell, Voltage dips, Transient over-voltage, Interruptions
› Measure and record Power and Power factor, Active/Reactive energy, Demand, Load fluctuation (with graph display), Voltage and current
› PC software bundled
› 1P2W to 3P4W› 50/60/400Hz Measurement› GPS Clock Synchronization (optional)› Power factor, sags, swells, flicker, transients› Harmonics to the 50th› Accurate High Speed Transient at 2MHz sampling› Detection and waveform display› Four current and Four voltage channels› Advanced PC software
› 3P4W from 0.5A up to 5000A, and 75W to 9MW› Power factor, integrated power, harmonics, demand› Active power, reactive power, apparent power, frequency› Optional advanced PC software3169-21:› With D/A output
3197
PW3198
3169-20/-21True RMS Power Meter
Power Quality Analyzer
Power Quality Analyzer
4MB of Internal Memory
USB interface for PC Networking
Large, Brilliant LCD Screen lets you view Event list and Waveforms in a Single Window
RS-232C Interface
PC Card slot
Record from a minimum of 1 cycle up to 60 minute intervals
Multilingual displaySelect from four languages, including Japanese and English.
Multilingual display
www.hioki.com6
CLA
MP
ME
TE
RS
- A
t a
Gla
nce CLAMP ON HiTESTERs
Table of functions3280-10 MEAN3280-20 True RMS
3281 True RMS3282 True RMS
3283 True RMS3284 True RMS3285 True RMS3285-20 True RMS
AC AC Leak AC/DC, AC+DC
AC Current ranges 42.00/420.0/1000 A 3281: 30.00/300.0/600 A 3282: 30.00 /300.0/1000 A 10.00m/100.0m/1/10/200 A
AC, AC+DC (RMS or Peak value)
3284: 20.00/200.0A 3285/3285-20: 200.0/2000A
Other current ranges None
Wave peak value at AC Current 3281: 75.0 to 1000A peak, 3 ranges 3282: 75.0 to 1700A peak, 3 ranges
NoneDC (Average or Peak value)
3284: 20.00/200.0A DC 3285/-20: 200.0/2000A DC
AC Voltage ranges 4.200/42.00/420.0/600V 300.0/600V NoneAC, AC+DC
(RMS or Peak value)30.00/300.0/600V
Other voltage ranges DC Voltage range:420.0m/4.2/42/420/ to 600V
Wave peak value at AC Voltage up to 750/1000V peak None DC (Average or Peak value)
30.00/300.0/600V
Other functions
Resistance: 420.0 to 42.00 MW, 6 rangesAccuracy: ±2.0 % rdg. ±4 dgt.(at 420 to 420 kW range)Continuity: 420.0W(Buzzer sounds less than approx. 50W ±40W)
Distortion check:1 to 5 Crest factorResistance: 1k or 10kW range Frequency: 30.0 to 1000 HzMode: Slow/Peak/C.F./RMS Record mode/Auto-off/ Conduction
Frequency: 30.0 to 1000 HzFilter function: 180Hz±30Hz/-3dB
Resistance: 1k or 10kW range (3285-20 only)
Analog outputPrinter output None None
DC or AC 1V / f.s.(200A range:2V / f.s.)Level output with REC modeWaveform output with MON mode
DC or AC 1V / f.s.Level output with REC modeWaveform output with MON mode (except for 3285-50)
Basic Accuracy (at 50 or 60Hz)
AC current: ±1.5 % rdg. ±5 dgt.AC voltage: ±2.3 % rdg. ±8 dgt.DC voltage: ±1.3 % rdg. ±4 dgt.Continuity: ±2.0 % rdg. ±6 dgt.
AC current: ±1% rdg. ±5 dgt.AC voltage: ±1% rdg. ±3 dgt.Peak: ±3% rdg. ±5 dgt.Frequency: ±0.3% rdg. ±1 dgt.
10m to 10A range: ±1.0 % rdg. ±5 dgt.200A range: ±1.5 % rdg. ±5 dgt.Frequency: ±0.3 % rdg. ±1 dgt.
AC current: ±1.3% rdg. ±3 dgt. AC voltage: ±1.0% rdg. ±3 dgt. Frequency: ±0.3% rdg. ±1 dgt.
Frequency characteristics
AC current / voltage
AC voltage: 50 to 500HzAC current: 50 or 60Hz (3280-10)40 to 1kHz (3280-20)
40 to 1000 Hz 40 to 2 kHz 3284: DC, 10 to 2kHz 3285/3285-20: DC, 10 to 1kHz
Display Digital /LCD, maximum 4199 dgt.
Digital /3000 dgt. Bar graph /35 seg.
Digital /2000 dgt. Bar graph /35 seg.
Current / 2500 dgt. Voltage / 3750 dgt.Bar graph /35 seg.
Sampling rate 2.5 times /sec or 1 time /3 sec 2 or 4 times /sec(Slow: 1 time /3 sec)
2 or 4 times /sec (Slow: 1 time /3 sec)
2 or 4 times /sec(Slow: 1 time /3 sec)
Crest factor(RMS)
3280-10: Not defined3280-20: 2.5 or less
(current measurement only)
2.5 (1.7 at 600/1000A, 600 V range) 2.5 (1.5 at 200A range) 3284: 2.5, 1.5 (200A range)
3285/3285-20: 2.5, 1.42 (2000A range)
Effect of externalmagnetic fields Yes; level not defined
3281: 1.5A equivalent max. 3282: 0.2A equivalent max. (at 400 A/m)
7.5 mA equivalent max. at 400 A/m
3284: 0.5A equivalent max. 3285/-20: 2.0A equivalent max. (at 400 A/m)
Max. circuit voltage 600V AC rms 600V AC rms 300 V AC rms 600V AC rms
Core jaw dia. f33 mm 3281: f33 mm3282: f46 mm f40 mm 3284: f33 mm
3285/3285-20: f55 mm
Power supply CR2032 (3 VDC) × 1 6F22 (006P) × 1 6F22 (006P) × 1 or AC adapter 6F22 (006P) × 1 or AC adapter (except for 3285-20)
Dimensions/mass57W × 175H × 16D mm(2.24W × 6.89H × 0.63D in), 100 g (3.5 oz)
3281:62W × 216.5H × 39D mm(2.44W × 8.58H × 1.54D in), 350 g (12.3 oz)3282: 62W × 230H × 39D mm(2.44W × 9.06H × 1.54D in), 400 g (14.1 oz)
62W × 225H × 39D mm(2.44W × 8.86H × 1.54D in),400 g (14.1 oz)
3284: 62W × 230H × 39D mm(2.44W × 9.06H × 1.54D in), 460 g (16.2 oz)3285/3285-20: 62W × 260H × 39D mm(2.44W × 10.24H × 1.54D in), 540 g (19.0 oz)
Includedaccessories
TEST LEAD L9208 (1) CARRYING CASE 9398 (1)
TEST LEAD L9207-10 (1)CARRYING CASE 9399 (1 for 3281/3282) Hand strap (1)
CARRYING CASE 9399 (1)Hand strap (1)
TEST LEAD L9207-10 (1)CARRYING CASE 9399 (1 for 3284)CARRYING CASE 9345 (1 for 3285/3285-20)Hand strap (1)
7
CLA
MP
ME
TE
RS
- A
t a
Gla
nce
3286-20 True RMS3287 True RMS3288 MEAN3288-20 True RMS
3290 True RMS3290-10 True RMS
3291-50 True RMS 3293-50 True RMS
AC Power AC/DC AC/DC AC AC Leak
20.00/200.0/1000 A 3287: 10.00/100.0A 3288: 100.0/1000A 3288-20: 100.0/1000A
3290+9691: 20.00A/100.0A 3290+9692: 20.00A/200.0A 3290+9693: 200.0A/2000A AC+DC, AC RMS, AC MEAN
60.00/600.0/1000 A 30.00 m/300.0 m/6.000/60.00/600.0/1000 A
NoneDC current range
3287: 10.00/100.0 A DC 3288/-20: 100.0/1000 A DC
DC current range 3290+9691 : 20.00A/100.0A DC 3290+9692 : 20.00A/200.0A DC 3290+9693 : 200.0A/2000A DC
None None
150.0/300.0/600 V 4.200/42.00/420.0/600V None None None
None DC voltage range420.0m/4.200/42.00/420.0/600 V None None None
Power (Single-phase or 3 phase): 3kW to 600kW(Single-phase)6kW to 1200kW(3-phase)Power factorPhase angleFrequency: 30.0 to 1000HzVoltage/current harmonic levels
Resistance: 420.0W/4.200W/42.00kW/420.0kW/4.200MW/42.00MWAccuracy: ±2.0% rdg. ±4 dgt.(at 420 to 420kW range) Continuity: 420.0W(Buzzer sounds less than approx. 50W ±40W)
Frequency : 10.00Hz/100.0Hz/1000 Hz None None
None None
DC, or AC Current : 2V/f.s.Level output with REC modeWaveform output with MON modeInteg./Frequency : 1V/f.s.
None None
AC current: ±1.3 % rdg. ±3 dgt.AC voltage: ±1.0 % rdg. ±3 dgt.Power: ±2.3% rdg. ±5 dgt. (1f) ±3.0% rdg. ±10 dgt. (3f)(Accuracy guaranteed only for 50/60Hz cosf=1)
AC current: ±1.5 % rdg. ±5 dgt.AC voltage: ±2.3 % rdg. ±8 dgt.DC voltage: ±1.3 % rdg. ±4 dgt.DC current: ±1.5 % rdg. ±5 dgt.Continuity: ±2.0 % rdg. ±6 dgt.
AC/DC/AC+DC Current: ±1.3 % rdg.+3 dgt. (Typical)Frequency: ±0.3 % rdg.+1 dgt. (Typical)
AC current: ±1.5 % rdg. ±5 dgt.
AC current: ±1.5 % rdg. ±5 dgt.
AC current: 45 to 1kHzAC voltage: 30 to 1kHz
AC current: 3287 DC, 10 to 1kHzAC current: 3288/-20 DC, 10 to 500HzAC voltage: 30 to 500Hz
DC to 500Hz (9691)DC to 1kHz (9692, 9693) ±2.3 % rdg. + 8 dgt.
45 to 400Hz 45 to 400Hz
Digital /LCD, maximum 6000 dgt.
Digital /LCD, maximum 4199 dgt.
Digital / LCD maximum 3000 dgt.Bar graph / 20 seg. 3290-10 maximum 9999 dgt.
Digital /LCD, maximum 6000 dgt.Bar graph / 91 seg.
Digital /LCD, maximum 6000 dgt.Bar graph / 91 seg.
Normal: 1 time /sec (Slow: 1 time /3 sec) 2.5 times /sec
3290 FAST : 4 times/sec(3290-10 AC, AC+DC FAST: 10 times/sec)Normal: 2 times/ sec, Slow : 1 time / 3sec
Maximum 1.1 sec Maximum 1.1 sec
2.5 (1.7 at 1000 A, 600 V range)3287: 2.5 (150A, 1000V maximum)3288: Not defined3288-20: 3 (1000A/2 max, voltage/1.5 max.)
2.5 or less 2.81.68 (1000 A range)
2.81.68 (1000 A range)
1.00 A equivalent max. at 400 A/m Yes; level not defined
9691 : 0.5 A equivalent max. at 400 A/m9692 : 0.7 A equivalent max. at 400 A/m9693 : 2.0 A equivalent max. at 400 A/m
Yes; level not defined 7.5 mA equivalent max. at 400 A/m
600 V AC rms 600 V AC rms 600 V AC rms 600 V AC rms 300 V AC rms
f55 mm or80mm busbar
3287: f35 mm3288/-20: f35 mm
9691 : f35 mm, 9692 : f33 mm9693 : f55 mm
f30 mm f24 mm
6LR61/6LF22 (006P) × 1 CR2032 (3VDC) × 1 LR6(AA alkaline battery) × 4 or AC adapter CR2032 (3VDC) × 1 CR2032 (3VDC) × 1
100W × 287H × 39D mm(3.94W × 11.3H × 1.54D in), 650 g (2.9 oz)
57W × 180H × 16D mm(2.24W × 7.09H × 0.63D in)
3287: 170 g (6.0 oz)3288/-20: 150 g (5.3 oz)
3290/-10 : 155W × 98H × 47D mm(6.10W × 3.86H × 1.85D in), 545 g (19.2 oz)9691 : f 35 mm (1.38 in), 2 m (6.56 ft)9692 : f 33 mm (1.30 in), 2 m (6.56 ft) 9693 : f 55 mm (2.17 in), 2 m (6.56 ft)
50W × 136H × 26D mm(1.97W × 5.35H × 1.02D in)
115 g (4.1 oz)
50W × 130H × 26D mm(1.97W × 5.12H × 1.02D in)
135 g (4.8 oz)
VOLTAGE CORD L9635-01 (1)CARRYING CASE 9245 (1)Hand strap (1)
TEST LEAD L9208 (1) CARRYING CASE 9398 (1) strap CARRYING CASE 9757 (1)
strapCARRYING CASE 9757 (1)
strap
www.hioki.com8
DIG
ITA
L M
ULT
IME
TE
RS
› 51m to 1000 AC and DC V› 510µ to 10 AC and DC A› Resistance, Conductance, Frequency, Continuity, Diode, Capacitance and Temperature› Peak hold, duty pulse width and decibel conversion
3801-50 & 3802-50
› 420m to 1000 AC and DC V› 42µ to 10 AC and DC A› Resistance and Frequency› Continuity and Diode Check
3801-50 3802-50
3256-50 3257-50True RMS
Dual display with bright LCD backlight
AC+DC
USB PC interface
1ms Peak Hold
True RMS True RMS
Terminal shutter interlock mechanism exposes only the
correct terminals for connection in the currently selected function
High-speed response and bar graph display
CATIV 600V/CATIII 1000V Safe
With a sleeve attached to the tip of test leads,short-circuit accidents can be prevented.
NEW!
Sleeve attached No Sleeve attached
Conforms to safety standardIEC61010-031 (revised) for hand-held probes
Detachable!When a sleeve is not attached, the test leads can only be used in a CATII environment.
Included as a standard accessory (This sleeve cannot be attached to previous products)*When used in CATIII environments, test pin sleeves are required.
sleeve
What are the new and additional requirements of the international safety standards?1. "Exposed metal part must be 4mm or shorter" (Previously, 19mm max.) for CAT III and IV environments to prevent short-circuits from occurring.2. Double-coating with different colors enables you to identify the wear condition of the test leads. (Previously, single-coated)
New insulated test pin sleeve prevent shortNo sleeves attached to the tip of test leads?DANGER of short-circuit accident!!
Previousmodel
For the instruments on this page, when the test lead sleeves are not attached, the instrument can only be used in a CATII environment.
CATIV 600V/CATIII 1000V Safe
Please refer to pages 10-11 for detailed specifications.
9
DIG
ITA
L &
AN
ALO
G M
ULT
IME
TE
RS
› Built-in current limiter and fuse capable of withstanding 1000V to prevent short-circuit accidents
› Dust-proof, water-proof construction - perfect for industrial power lines
› 420m to 1000 AC and DC V + Resistance
› Handy Card-sized DMM backed by HIOKI Quality› 420m to 500 DC V› 4.2 to 500 AC V› Resistance and Continuity
› Hybrid power system supporting environmental conservation
› 4.2 to 600 AC V› 420m to 600 DC V › Resistance
› Tough & Durable Analog Multimeter for Quick Readings
› 12 to 600 AC V› 0.3 to 600 DC V› 60µ to 300m DC A › Resistance
› Basic Analog Multimeter with wide range
› 6 to 600 AC and DC V› 10k to 1MΩ Resistance (Not CE marked)
3255-503244-60
3245-60
3030-10 3008
› 4.2 to 600V AC V› 420m to 600 DC V› Resistance› 150 hours of continuous use on a single battery
3246-60Pencil HiTESTER
Ultra-bright diode light lets you find hard-to-reach spots in dark locations 600V circuit protection
- no fuse required Test probe fits neatly in the back
Bright LCD backlight
Fully automatic wide range + max. 4199 reading
150 hours of continuous use on a single battery
DROP
PROOF DROP
PROOF
Sleeve attached No sleeve attached
For the instruments on this page (except Model 3008), when the test lead sleeves are not attached, the instrument can only be used in a CATII environment.
Please refer to pages 10-11 for detailed specifications.
www.hioki.com10
DIG
ITA
L &
AN
ALO
G M
ULT
IME
TE
RS
- A
t a
Gla
nce
3030-10Average rectified
3244-60Average rectified
3245-60Average rectified
3246-60Average rectified
DC Voltage ranges
0.3 V to 600 V7 ranges
420.0 mV to 500V 5 ranges
420.0 mV to 600 V5 ranges
420.0 mV to 600 V 5 ranges
Best accuracy ±2.5 % f.s. ±0.7% rdg. ±4 dgt ±1.3 % rdg. ±4 dgt. ±1.3 % rdg. ±4 dgt.
AC Voltage ranges
12 V to 600 V5 ranges
4.200 V to 500V4 ranges
4.200 V to 600V4 ranges
4.200 V to 600V4 ranges
Best accuracy ±2.5% f.s. ±2.3 % rdg. ±8 dgt. ±2.3% rdg. ±8 dgt. ±2.3% rdg. ±8 dgt.Frequency
characteristics at AC Voltage None 50 to 500 Hz 50 to 500 Hz 50 to 500 Hz
Resistance ranges
0 to 3kW4 ranges
420.0 W to 42.00 MW 6 ranges
420.0W to 42.00MW6 ranges
420.0W to 42.00MW6 ranges
Best accuracy ±3 % of scale length ±2.0% rdg. ±4 dgt. ±2.0 % rdg. ±4 dgt. ±2.0 % rdg. ±4 dgt.
DC Current ranges 60mA to 300 mA, 3 rangesNone None None
Best accuracy ±3 % f.s.
AC Current ranges
None None None None
Best accuracy
Frequency characteristicsat AC Current None None None None
Frequency rangesNone None None None
Best accuracy
Continuity None 50W ±40W 50W±40W 50W±40W
Diode check None None None judgement only 3.4 V open terminal voltage
Other functions None NoneLight meter function
("1000" equates to approx. 50,000 lx)
None
Auto power save None (Cancel impossible) (Cancel possible) (Cancel possible)
Range switching Manual Auto Auto or Manual Auto or Manual
Display Analog Digital/LCD, max. 4199 dgt
Digital/LCD, max. 4199 dgt.
Digital/LCD, with Back lightmax. 4199 dgt.
Safety EN61010CAT III 600V
EN61010Pollution degree 2 CAT II 600VCAT III 300V
EN61010Pollution degree 2CAT III 600VCAT IV 300V
EN61010CAT III 600VCAT IV 300V
Bar graph display None None None None
Sampling rate None 2.5 times /sec 2.5 times/sec 2.5 times/sec
Power supply R6P (AA) × 2 batteries CR2032 × 1 batteries(Continuous use 150 hours)
CR2032 × 1 batteries(Continuous use 150 hours)
CR2032 × 1 batteries(Continuous use 150 hours)
Dimensions/mass
95W × 141H × 39D mm(3.74W × 5.55H × 1.54D in)
280 g (9.9oz)
55W × 109H × 9.5D mm(2.17W × 4.29H × 0.37D in)
60g (2.1 oz)
60W × 135H × 23D mm(2.36W × 5.31H × 0.91D in)
140 g (4.9 oz)
30W × 182H × 26.5D mm(1.18W × 7.17H × 1.04D in)
80g (2.8oz)
Includedaccessories
TEST LEAD (1)Fuse (1)CARRYING CASE 9390 (1)
Hard case (1)Sleeve (1) Sleeve (1) Sleeve (1)
Basic
11
DIG
ITA
L &
AN
ALO
G M
ULT
IME
TE
RS
- A
t a
Gla
nce
High Performance3255-50
Average rectified3256-50
Average rectified3257-50
Ture RMS3802-50
Ture RMS3801-50
Ture RMS
420 mV to 1000 V 5 ranges
420.0 mV to 1000 V5 ranges
420.0 mV to 1000 V5 ranges
51.000 mV to 1000 V7 ranges
51.000 mV to 1000 V7 ranges
±0.5 % rdg. ±4 dgt. ±0.5% rdg. ±2 dgt. ±0.5% rdg. ±2 dgt. ±0.03% rdg.± 5dgt. ±0.025% rdg.± 5dgt.
420.0 mV to 1000 V5 ranges
420.0 mV to 1000 V5 ranges
420.0 mV to 1000 V5 ranges
51.000 mV to 1000 V7 ranges
51.000 mV to 1000 V7 ranges
±1.2% rdg. ±4 dgt. ±1.2% rdg. ±3 dgt. ±1.2% rdg. ±3 dgt. ±0.6% rdg. ± 25dgt. ±0.4% rdg. ± 25dgt.
50 to 500 Hz 50 to 500 Hz 50 to 500 Hz 30 to 30 kHz 20 to 100 kHz
420.0W to 42.00 MW6 ranges
420.0 W to 42.00 MW6 ranges
420.0 W to 42.00 MW6 ranges
510.00 W to 51.000 MW6 ranges
510.00 W to 510.00 MW7 ranges
±0.7 % rdg. ±4 dgt. ±0.7% rdg. ±2 dgt. ±0.7% rdg. ±2 dgt. ±0.08% rdg.± 5 dgt. ±0.05% rdg.± 5 dgt.
None42.00 mA to 10.00 A, 6 ranges 42.00 mA to 10.00 A, 6 ranges 510.00 mA to 10.000 A, 6 ranges 510.00 mA to 10.000 A, 6 ranges
±1.5 % rdg. ±4 dgt. ±1.5 % rdg. ±4 dgt. ±0.1% rdg.± 25 dgt. ±0.05% rdg. ± 25 dgt.
10.00A to 1000A7 ranges
Use with optional Clamp-on probes
42.00 mA to 10.00 A6 ranges
42.00 mA to 10.00 A6 ranges
510.00 mA to 10.000 A6 ranges
510.00 mA to 10.000 A6 ranges
±2.0% rdg. ±4 dgt.(plus clamp-on probe's accuracy) ±2.5 % rdg. ±5 dgt. ±2.5 % rdg. ±5 dgt. ±0.8% rdg.± 20dgt. ±0.7% rdg. ± 20 dgt.
None 50 to 500 Hz 50 to 500 Hz 30 to 20 kHz 20 to 100 kHz
None
0.50Hz to 500.0 kHz, 5 rangesInput level:
800mV to 1000V rms
0.50Hz to 500.0 kHz, 5 rangesInput level:
800mV to 1000V rms
0.5 Hz to 999.99 kHz, 5 rangesInput level:
0.5V to 1000V rms
0.5Hz to 999.99 kHz, 5 rangesInput level:
0.5V to 1000V rms
±0.02% rdg. ±1 dgt. ±0.02% rdg. ±1 dgt. ±0.02% rdg. ± 3 dgt. ±0.02% rdg. ± 3 dgt.
50W±40W 50W ±40W or less 50W ±40W or less Buzzer sounds for less than 1000 count in each range
Buzzer sounds for less than 1000 count in each range
judgement only 3.4 V open terminal voltage
3.4 V open terminal voltage
3.4 V open terminal voltage
3.1 V open terminal voltage
3.1 V open terminal voltage
NoneVoltage detect function Hold-auto functionRelative function
Voltage detect function Hold-auto functionRelative function
Capacitance, Data hold,dBm measurement,Duty ratio/Pulse width,Temperature, 1ms peak holdRelative, Max/Min/Ave, USB
AC+DC measurement, Pulse output Capacitance, Data hold, dBm measurement, Duty ratio/Pulse width, Temperature, 1ms peak hold Relative, Max/Min/Ave, USB
(Cancel possible) (Cancel possible) (Cancel possible) (Cancel possible) (Cancel possible)
Auto or Manual Auto or Manual Auto or Manual Auto or Manual Auto or Manual
LCD, max. 4199 dgt.
Digital/LCD,max. 4200 dgt. (all mode)max. 19999 dgt. (Frequency)
Digital/LCD,max. 4200 dgt. (all mode)max. 19999 dgt.(Frequency)
Digital/LCD, max. 51000 dgt.with Back light
Digital/LCD, max. 51000 dgt.with Back light
EN61010Pollution degree 2 CAT II 1000VCAT III 600V
EN61010Pollution degree 2 CAT II 1000V, CAT III 600V
EN61010Pollution degree 2 CAT III 1000V, CAT IV 600V
EN61010Pollution degree 2CAT III 1000V, CAT IV 600V
EN61010Pollution degree 2CAT III 1000V, CAT IV 600V
None Yes Yes Yes Yes
2.5 times/sec2.5 times/sec (all mode)5 times/sec (Frequency)25 times/sec (Bar graph)
2.5 times/sec (all mode)5 times/sec (Frequency)25 times/sec (Bar graph)
3.75 times/sec 3.75 times/sec
R03(AAA) × 2 dry batteries
(continuous use 200 hours)
R03(AAA) × 2 dry batteries
(Continuous use 100 hours)
R03(AAA) × 2 dry batteries
(Continuous use 100 hours)
6LR61 × 1 (9.0V)(Continuous use 50 hours)
6LR61 × 1 (9.0V)(Continuous use 50 hours)
70W × 145H × 31D mm(2.76W × 5.71H × 1.22D in)
210g (7.4oz)
76W × 167H × 33D mm(2.99W × 6.57H × 1.30D in)
260 g (9.2oz)
76W × 167H × 33D mm(2.99W × 6.57H × 1.30D in)
260 g (9.2oz)
100W × 202H × 57D mm(3.94W × 7.95H × 2.24D in)
680 g (24.0oz)
100W × 202H × 57D mm(3.94W × 7.95H × 2.24D in)
680 g (24.0oz)
TEST LEAD (1)Fuse (1)CARRYING CASE 9371 (1)
TEST LEAD (1)Fuse (2)CARRYING CASE 9378 (1)
TEST LEAD (1)Fuse (2)CARRYING CASE 9378 (1)
TEST LEAD (1)Holster (1)
TEST LEAD (1)Holster (1)
www.hioki.com12
DIG
ITA
L &
AN
ALO
G IN
SU
LAT
ION
TE
ST
ER
S
Bar graph
Store test leads while connected plus
Innovative sliding cover system
Store up to 20 sets of data
Large, easy-to-read display
Precise taut-band movement gives quick readings Constant
battery check
Optional lighted remote control test lead makes testing even faster
4 ranges
Automatically calculate and display PI (Polarization Index) and DAR (Dielectic
Absorption Ratio)
Step voltage testing, temperature compensation, temperature
measurement, and leakage current
Store up to 100 sets of insulation data and send to PC via USB interface and free software
Safety shutter keeps temperature and power
terminals away from high voltage contact
Check theBattery Status
Check forLive Circuits
Luminous ScaleSee better in the dark
› 20 to 500Ω› Voltage comparison method › 3.6m AC A measurement current
› 10 to 1000Ω› 2-wire measurement method on 100Ω & 1000Ω ranges› 15m AC A measurement current
3453/3453-01
3490
3143 3151
3455
IR4000 series
3453-01: Includes semi-hard case1kV Insulation Tester
Multi-range Analog
Earth Testing
No grounding rods required
Earth Testing2-pole or 3-pole method for testing earth resistance
Selectable frequency
range
5kV Insulation Tester
Single-range Analog
Bright red light warns of live voltage
3 or 4 ranges + 200mA continuity testing
Store test leads while connected plus
Innovative sliding cover system
34541kV Insulation Tester
13
Constant battery check
DIG
ITA
L &
AN
ALO
G IN
SU
LAT
ION
TE
ST
ER
S -
At
a G
lanc
e
Analog
Single Range Multi-range
IR4016-20 IR4017-20 IR4018-20 3490Insulation Resistance Measurement
Testing voltageRated resistance
500V DC/100 MΩ
500V DC/1000 MΩ
1000V DC/2000 MΩ
250V/100 MΩ, 500V/100 MΩ1000V/4000 MΩ
Center scale value 2 MΩ 20 MΩ 50 MΩ 1 MΩ (250/500V), 50 MΩ (1000V)
1st effectivemeasuring range
0.1 to 50 MΩ 1 to 500 MΩ 2 to 1000 MΩ 0.05 to 50 MΩ (250/500V)2 to 1000 MΩ(1000V)
±5% of indicated valueOpen circuit voltage 1 to 1.2 times of rated output voltage
Rated current 1mA (Tolerance: 1 to 1.2 times of the rating value)Overload protection 600V AC (10 sec.) 1200V AC (10sec.) 1200V AC (10sec.)AC voltage Measurement
Measuring range 0 to 600 V (50/60 Hz)Accuracy ±5% of maximum scale value
Input resistance 500 kΩ or more (50/60Hz) 100 kΩ or more (50/60Hz)Overload protection 600V AC 1200V AC
Multi-range
Digital
3455 3453 3454-11 3454-10Insulation Testing
50V 200.0MΩ125V 20.00MΩ 200.0MΩ250V 250GΩ 2000MΩ 500.0MΩ 2000.0MΩ500V 500GΩ 2000MΩ 500.0MΩ 2000.0MΩ
1000V 1.00TΩ 4000MΩ 4000.0MΩ2500V 2.50TΩ5000V 5.00TΩ
Short Circuit Current 2mA 1.2mA(1000V: 0.6mA) 1.2mA
Best Accuracy ±5% rdg. ±5dgt. ±2% rdg. ±3dgt. ±3% rdg. ±4dgt.AC Voltage Testing 50 to 750V 0 to 600V 0 to 750VDC Voltage Testing ±50V to 1.00kVContinuity Testing yes yes
Measurement Current 1mA 200mAOpen-circuit Voltage 4 DCV 5 DCVLeakage Current Testing yes
Sampling rate 1 time/sec 2 times/sec 2 times/secData Storage 100 sets 20 sets
Display 999 4000 4000Bar Graph yes yes
Safety CATIV 600V CATIII 600V CATIII 600V
Accessories TEST LEAD L9787 (1.2m)
included as a standard accessory(This sleeve cannot be attached to previous products)
When measuring in a CAT III environment, be sure to attach the sleeve to the test leads.
Detachable!
Conforms to safety standardIEC61010-031 (revised) for hand-held probes
www.hioki.com14
DIG
ITA
L &
AN
ALO
G M
ULT
IME
TE
RS
- A
t a
Gla
nce
BA
SIC
TE
ST
ING
AN
D M
AIN
TE
NA
NC
E T
OO
LS
› 70 to 1000 AC V (max 600V AC V on the 3129)› Auto power off saves battery life
› Sensitivity level catered to 120V installations
› 70 to 600 AC V› Non-Metallic contact
3120
3129-10
3258
Also
Ava
ilabl
e: 3
129 P
hase Detector for thinner conductors
2999
dduuccttoorrss
CATIII 600V
Safety HiTESTER
AC Voltage Detector
Phase Detector
Extra-wide clips to clamp up to Ø 40mm thick conductors
Bright Red LED and clear buzzer
Compact body fits neatly in the palm of your hands
Non-metallic resin test probes prevents
electric shock
Absolutely NO metal exposure ensures safety at the worksite
Non-Metal Contact Voltage Testing and Detection
World’s First!
Bright green light indicates sufficient
power supply
Bright red light and clear buzzer warns of live voltage
HIOKI’s proprietary technology lets you measure right through line insulation
True RMS method measures 30 to 600V AC accurately and displays on a crystal clear LCD
CATIV 600V/CATIII 1000V Safe
CATIV 600V/CATIII 1000V Safe
Clamp Diameter2.4mm to 17mmClamp Diameter2.4mm to 17mm
When apply ing any vol tage detector, always test on known live before and after use
15
TE
MP
ER
ATU
RE
, LU
X, S
OU
ND
, TA
CH
O &
LA
N T
ES
TIN
G
› Best sampling: 62.5 ms › Best accuracy: ±1dgt. (Up to 9999 counts)
Also
Ava
ilabl
e: 3
129 P
hase Detector for thinner conductors
FT3405•FT3406
Check for wire connec-tion status, cable length, and connection destina-tion of twisted pair cables
Temperature Testing
Tacho Testing
FT3406 only• AC Adapter (option) • Analog output and pulse output
Long non-contact distance
500 mm/19.7”
3441 (-02)* 3442 3443 3444 3445 3419-20 FT3700-20 FT3701-20
Measurement Method K type thermocouple
Non-contact infrared sensor Non-contact infrared sensor to Thermopile
Non-contact infrared sensor to Thermopile 2-beam laser marker
Laser marker 2-beam laser markerGuaranteed accuracy Range
-100 to 1300°C (-148°F to 2372°F)
-50 to 500°C (-58°F to 932°F)
-35 to 500°C (-31°F to 932°F)
-35 to 500°C (-31°F to 932°F)
Best Resolution 0.1˚C (-100 to 199. 9˚C)0.1˚F (-148˚F to 392˚F) 0.1°C 0.1°C 0.1°C
Best Accuracy ±0.1% rdg.±0.8°C (-100 to 199.9˚C)±0.1% rdg. ±1.5˚F (-148˚F to 392˚F) ± 1.0 % rdg. ± 2 % rdg.
or ± 2 °C± 2 % rdg. or ± 2 °C
Sampling (Response time) 2 times/sec 1 time/0.8sec (1.6 sec) 2 times/sec 1 secChannels 1 1 1 1Field Diameter Ø24mm
at 1mØ2.5mm at 73mm Ø125mm at 1m Ø83 mm
at 1 mØ100 mm
at 3 mWater Resistance IP54 IP54Data Recording Max/Min Max/Min Max/Min/Avg/Max-MinPC Interface RS-232CPC Software Model 3909Output to Printer Analog Output
3423Lux Testing
20 to 200000lx range, 199,900 lx max. scale
Detachable sensor head using optional cord
Ultra-sensitive sensor offers ±4%rdg.±1dgt. accuracy
Analog output
3665-20LAN Cable Testing
Identify up to 21 cable connection destinations using coded terminators
Check shielded and crossover Cables
Detect Split Pairs that are usually the cause of bad connections
FT3432Sound Level
30dB to 130dBAnalog output
Simple operation—no range switching needed
Compact, lightweight design for easy one-
handed operation
* 3441, 3442: °C display only, 3441-02: °C/°F display selectable
Drop proof (1m, main unit only)
Dust-proof construction (IP 50)
Available soonSchedule to be discontinued
Also
Ava
ilabl
e: 3
555 BATTERY HiTESTER for compact storage batteriesAAll
ssooAAvv Av A
aaiillaa
bbllee
33355555555555
ppaacctt ssttoorraaggeerriieess
In some cases, power lines may carry voltage spikes of several times the normal supply voltage. For reasons of safety, ordinary testers should not be used to measure power lines carrying more than 250V. When measuring such power lines, always use a tester with built-in overcurrent protection to guard against short circuits, such as Model 3008 and a device showing the CAT III marking.
Note: An industrial power line refers to a high-capacity supply circuit to equipment in factories or offices. A high-capacity supply circuit refers generally to a line carrying 20 A or more. This does not therefore include supply lines protected by overcurrent protection (fuses) or distribution breakers.
1. To avoid short circuits and electric shock accidents when using a clamp-on sensor, use only with power lines carrying voltages within the rating limit of the sensor.2. Products shown with this icon may only be used with insulated conductors (wires or cables that are covered a proven insulation material.)
BA
TTE
RY
TE
STE
RS
Insulatedconductor
The CE mark certifies that a product complies with electrical safety standards established by European Community directives (EC directives). These EC directives require conformance of a product to EN/IEC standards for electrical safety.•HIOKI's products bearing the CE Mark are designed to confirm to the Low Voltage and EMC directives based on the EC directives.•The Low Voltage directive is applicable to products operating from 50 to 1000V AC and 75 to 1500V DC, and require protection from electrical hazards such as electric shock.•The EMC directive requires suppression of emissions of harmful electromagnetic radiation, and the ability to withstand exposure to external electromagnetic radiation without malfunction.
3554 3555Ideal for UPS batteries Compact batteries for mobile devicesResistance Testing 3mΩ to 3Ω, 4 ranges 300mΩ to 30Ω, 3 rangesBest Resolution 1 μΩ 100 μΩVoltage Testing 6 or 60 DC V, 2 ranges 3 or 30 DC V, 2 rangesBest Resolution 1 mV 1 mVTemperature Testing -10 to 60 °CBest Resolution 0.1 °CSampling 1 time/sec 1.25 times/secComparator Storage 200 sets 10 setsData Storage 4800 setsPC Interface USBPC Software
3554Battery HiTESTER
0002E26-23M-03N Printed in Japan
Headquarters : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 FAX +81-268-28-0568 http://www.hioki.co.jp / E-mail: [email protected]
HIOKI USA CORPORATION : TEL +1-609-409-9109 FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail: [email protected]
All information correct as of Mar. 12, 2012. All specifi cations are subject to change without notice.
DISTRIBUTED BYHIOKI (Shanghai) Sales & Trading Co., Ltd. : TEL +86-21-63910090 FAX +86-21-63910360 http://www.hioki.cn / E-mail: [email protected] Offi ce : TEL +86-10-84418761 FAX +86-10-84418763 / E-mail: [email protected] Offi ce : TEL +86-20-38392673 FAX +86-20-38392679 / E-mail: [email protected] Offi ce : TEL +86-755-83038357 FAX +86-755-83039160 / E-mail: [email protected] INDIA PRIVATE LIMITED : TEL +91-731-6548081 FAX +91-731-4020083 E-mail: [email protected] SINGAPORE PTE. LTD. : TEL +65-6634-7677 FAX +65-6634-7477 E-mail: [email protected]
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
Quickly and accurately get a complete picture of the state of your backup power source
Auto data hold and Auto data storage lets you test the deterioration state of your entire UPS battery bank quickly and efficiently
Download test results and upload comparator tables via USB interface and free software
Wide 60V range
Store up to 4800 sets of test data
Extra-strong test probes
Comparator function