R. STAHL Fieldbus Solutions
Highlights and Examples
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page1
R. STAHL fieldbus involvement fieldbus competence since 1987
1987
intrinsically
safe fieldbus for
remote IO
1993
member of
InterOperable
Systems Project (ISP)
1995
member of FF
1996
Collaboration at
FF Application Guide
AG-163: 31.25 kbit/s
Intrinsically Safe Systems
1997
- IEC-fieldbus
- power supply
- intrinsically
safe Profibus DP
2003
Chairman of Profibus
working group
“Intrinsically safe
Profibus DP–RS485-IS”
2006
Fieldbus barrier
with 8 FISCO
Spurs
2009
Zone 1
FF HSE-RIO
prototype for F-ROM
working group
2010
- member of FF WIO
validation team
- FF power conditioner with
integrated physical layer
diagnostics
2012
- project F-ROM
demo working group
- FF tic-mark for
fieldbus barrier
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page2
ISbus – fieldbus products Everything for the high power trunk
Ex d / m
Fieldbus FF H1, high power trunk (Ex e/N.I.)
Ex i /FISCO
Zone 1
Ex i FDC
Ex e
FDC
Ex i
Digital I/O
Coupler
Ex nL/ic
or nA non-Ex
Spur
Protector
Zone 2 FDC
Zone 2
Terminator
Zone 2
Ex i FDC
Diagnostics Temp.
Coupler
Power Supply
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page3
ISbus Installations worldwide
some example projects
PETRONAS - Malaysia
BASF -Germany
PARADIP - India
Ruwais – Abu Dhabi
BASF-USA
PETROBRAS- Brazil
Novartis-Switzerland
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page4
FF Approvals tic-marks for all ISbus products
Fieldbus Power Supply
incl. physical layer diagnostics
Zone 1
Digital IO-Coupler
for discrete I.S. I/O
Foundation Device Coupler incl.
integrated power management
Diagnosis Communication
Module with H1 interface
Isolating Device Coupler with up to
8 spurs & power management
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights Page 5
Unique: Scalable supply & diagnostics with fieldbus power supply system
Physical layer diagnostics
(noise, jitter, level, unbalance)
Diagnostics integrated into
all fieldbus power supplies
Option 1: Handheld-mode – read all
pysical layer values via front interface & PC
Option 2: Pro-active mode – read all
pysical layer values and send alarm
via LED & relay (adjustable)
Option 3: Online mode – read
all pysical layer values and use
H1 network to communicate
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page 6
ISbus Fieldbus Power Supplies incl. physical layer diagnostics!
> For the redundant or simplex supply of H1 segments with 28 V / 500 mA
> Boost-mode: 2 FPS in parallel for up to 1 A output for extreme current requirements
> Integrated advanced physical layer diagnostics (acc. to NAMUR NE123)
> physical layer values accessible via front interface and standard Windows-PC
Standard: Advanced:
- front interface for PC connection
- online access via H1 & DCM
(Diagnosis Communication Module)
- front interface for PC connection
- adjustable alarming levels
- alarming via traffic light LED & relay
- online access via H1 & DCM
(Diagnosis Communication Module)
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights 7
ISbus Fieldbus Power Supply for installation and trouble shooting
Diagnostics interface & traffic light:
– Simple serial interface (USB or RS232)
– Diagnostics data download via free MS Windows tools
(e.g. HyperTerminal or STAHL Fieldbus Monitor)!
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights 8
Plus: unique redundant diagnostics when redundant FPS are used
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page 9
Installation in bus-Carriers simple, quick & robust
> 8-slot bus-Carrier for:
- 8 segments, simplex operation
- 4 segments, redundant operation
- optional DCM for H1 connection
> Installation in 16-slot bus-Carrier for:
- 8 segments, redundant operation
- optional DCM for H1 connection
Customized solutions for various hosts available
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page10
Diagnostics Interface Online Diagnostics via DCM & H1
DCM
power to host power to field
physical layer diagnostics
> reads physical layer data from up to
8 segments via FPS
> uses one of the H1 segments to send data
to host & management software
> is a native H1 device with function blocks
& transducer blocks
> support of new FF-912 field diagnostics
alarms
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page 11
Fieldbus Barrier: Ex i FDC For 4 or 8 I.S. / FISCO field devices
Connection of 4 & 8 I.S.
field devices acc. to
FISCO
Direct shielding
via earth bar
Capacitive shielding
via terminals
Connection srew,
spring clamp or
detachable screw
terminals
LEDs for diagnostics
Integrated, switchable
terminator
Unique Power Management
with Softstart reduces inrush
currents by up to 50 %
Available in Zone 1
& Zone 2 version
= cost optimized
solutions!
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page 12
Ex i FDC: Power Management unique Softstart function
Soft-Start: If the voltage on the trunk exceeds 16 V, one spur after the other is energized. This
reduces a high start-up current.
Conventional fieldbus barriers:
During start-up of a fieldbus segment, each device may consume a start-up current of up to 40 mA (see
IEC61158-2)
- the fieldbus power supply needs to supply this high current (= oversized for normal operation)!
- a higher voltage drop needs to be considered – this reduces allowed segment lengths
Fieldbus barrier with soft-start
During start-up each barrier starts one spur/field device after the other
- fieldbus power supply needs to deliver less power
- much lower voltage drop allows nearly double segment extension
conventional
fieldbus
barriers
with R. STAHL
soft-start
0
50
100
150
200
250
300
350
400
450
500
0 20 40 600
50
100
150
200
250
300
350
400
450
500
0 500 1000 1500 2000 2500
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights 02.2011 | page 13
Zone 1 Digital I/O Coupler 9413
Digital I/O Coupler for Foundation Fieldbus H1
with 8 Ex i discrete inputs (NAMUR) & 4 Ex i discrete outputs
also suitable for frequencies or counters up to 20 kHz
Digital Output: for standard Ex i solenoid valves: up to 13 V @ 30 mA
Open- / Short circuit detection
Integrated FF function blocks: DO, DI, MDO, MDI, AI & CI, LTB (Logic transducer block)
Optional LED Module for status and error
Functional overview
>© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights >page14
Ex e FDC – the Zone 1 spur protector Connection of non-I.S. fieldbus devices
Connection of 4 or 8
field devices (Ex d/m/e) Installation on DIN rail or
mounting plate
Direct grounding
with earth bar
Capacitive grounding
with terminals Connections screw
or spring clamp
terminals
LEDs for diagnostics
Unique Power Management
with Softstart reduces inrush
currents by up to 50 %
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page 15
Zone 2 Ex n FDC device couler for Zone 2 installations
same functionality (Power Management)
with up to 12 spurs for Ex ic or nL fieldbus
devices & detachable terminals
>© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights >S. 16
Fieldbus Terminator
Smallest Ex - Fieldbus terminator
Installation in standard M20 cable glands
versions: I.S. (FISCO fieldbus) and Ex m (non-Ex trunk) for Zone 1
required for Digital I/O coupler and other devices (not for FDCs!)
Patent pending
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights 02.2011 | page 17
Solutions for fieldbus technology
Enclosures, cable glands, cables & more!
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page18
The ISbus Fieldbus Wizard Version 2.0 Segment design made easy
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page 19
Fieldbus Barriers in customized enclosures some examples
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights 02.2011 | page 20
Ultra-compact 16 spur solution with Ex i FDC & maintenance switch
maintenance
switch:
de-energize trunk
for replacement of
FDC in Zone 1
enclosure with
small window:
monitoring of FDC
status LED
without opening
the cover
FDC with
detachable
terminals:
easy and cost
effective
maintenance of
Ex i spurs
compact design:
stainless steel
enclosure 360 x
360 mm for up to
16 I.S. spurs
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page 21
Customized system solutions for fieldbus
enclosure with
small window:
monitoring of FDC
status LED
without opening
the cover
Ex-connector:
hot-plug of non-
I.S. signals (trunk,
Ex e connections)
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights 02.2011 | page 22
Customized system solutions for fieldbus
maintenance switch:
de-energize trunk for replacement
of FDC in Zone 1
Ex i FDC:
for up to 3 x 4 I.S. / FISCO spurs
surge protection:
for trunk and/or spurs, integrated into enclosure
grounding concept:
separate grounding for armor & field signals
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights 02.2011 | page 23
Customized solutions Pharma-project: Fieldbus & Remote I/O
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights Seite 24
Remote I/O, FDC & solenoid valves
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights 02.2011 | page 25
ISbus in Mega-projects example: PARADIP India
field station:
stainless steel with 3 x 4 spur Ex i
FDC & maintenance switch
mega:
more than 2000 field stations and
approx. 6,700 Ex i FDC
© R. STAHL Schaltgeräte GmbH | SPP | André Fritsch | ISbus 2012 Highlights page 26