HIGH-TRO-REEL (Non-Tension Type)
The 3m long High-Tro-Reel units areinstalled consecutively along the side ofthe rail. Recommended for powering auto conveyors and monorails.
ULMulti-Lead Indoor Use Insulated Trolleys・UL Listed
21
Compact and easy to install.Multi-lead system allows setup even in confined spaces. Simply snap the unit onto the hanger. Using joiners when connecting the units vastly reduces setup time.
Installation on curved lines.Use on vertical curves with a radius of as tight as 800mm is possible, so it’s perfect for even multi-curve installations.(Horizontal curves are not possible.)
Power supply and commands transmitted simultaneously.With a single 5P or 6P High-Tro-Reel unit, both three-phase power and control commands can be transmitted simultaneously. Moving/controlling systems for transfer robots and auto conveyors can be installed even in confined spaces. (Please contact to ask us about more information.)
Turntable/traverser applicability.The guide cap enables smooth transfer of collector arms. Provides problem-free transfer between lines of different voltages in Flexible Manufacturing System (FMS) factories.
Flexible positioning of power supply points and circuit sections.With its center-feeding method, power can be supplied from anywhere on the line. Sections with different voltages can be installed by simply inserting insulating pieces.
!Please follow the safety precautions on page 2.
High-Tro-Reel unit
M5 screw(not included)
Joiner
Over R800A
Verticaldirection
Horizontaldirection
400A
In case of inward curves.(Outward curves are also possible.)
Power supply lead(not included)
Terminal
Center feed-in joiner
Insulating piece(guide insulator)
Insulating piece(cover)
Hanger
Center feed-in joiner
Guide cap(right-angled)
Guide cap(rear-facing)
Guide cap(front-facing)
Guide cap(right-angled)
10~20A
22
●60A units longer than 2997mm are available by special order (up to 6m)
Used to supply power. Also used to connect the High-Tro-Reel units.Note: Cannot be used as an end feed.※5P(DH5615K )
Used to supply power. Also used to connect the High-Tro-Reel units.Note: UL Approval PendingNote: Cannot be used as an end feed.※4P(DH56141K)
56
96
116
20 20 20
14
20 20
20 20 20 20
76
20 20 2020
14
14
14
14
20
14
3P
5P
6P
4P
14
14
140120105
A20
2020
20
26 58.6
26
140
2020
20A
20
120105
Tough-rubber sheath cable 8E
430
Crimp-onterminal 8-6
●Cross-section
Drawing shows a 5P joiner.
Drawing shows a 5P joiner.
●Both ends of the unit have terminals.Note: Not for use in high humidity/temperature
conditions.※6P(DH5606)
60A High-Tro-Reel unit (for indoor use only) UL Listed UL
Center feed-in joiner UL Listed UL
Center feed-in joiner (side-cable type)
Cat. No. Rating Standardlength
Weight(kg)
Units perbox
Units percarton
3P600V60A4P600V60A5P600V60A6P600V60A
3m3m3m3m
3.134.185.226.27
————
5555
DH5603DH5604DH5605DH5606
Cat. No. Rating A Weight(kg)
Units perbox
Units percarton
3P600V60A4P600V60A5P600V60A6P600V60A
6585
105125
0.350.460.560.66
1111
10101010
DH5613KDH5614KDH5615KDH5616K
Cat. No. Rating A Weight(kg)
Units perbox
Units percarton
3P600V60A4P600V60A5P600V60A6P600V60A
6585
105125
0.350.460.560.66
————
1111
DH56131KDH56141KDH56151KDH56161K
●Rating 3P, 4P, 5P, 6P at 600V, 60A●Conductor materials Copper (8㎟) + Copper (20㎟)●Insulating sheath material Rigid PVC (heat resistance: 75℃) Orange (hazard color), Munsell 2.5YR 6/13
23
HIGH-TRO-REEL (Non-Tension Type) Indoor Use Insulated Trolleys ULUL Listed
The High-Tro-Reel units are connected at intervals of 3m.Joiners allow for expansion and contraction of the units due to temperature fluctuations.
105
120140
A20
2020
20
26
20
25.3
3051.2
50
8 20
0.75ER=260
●Please use a special drill (DH5682) for insulating piece installation.
Special drill attachments
Special tools for mounting insulating pieces on a unit.Note: UL standards do not apply.
CenterMark
φ15.3
φ25
20
6.46.5
M4
M4
55
2710
61
3311
φ10 φ3
φ15φ
6
●The set consists of 2 different drills and a jig.
Drawing shows a 5P joiner.
Jig End mill drill bit (φ10)
Hole saw drill bit (φ15)
Joiner UL Listed UL
Cat. No. Rating A Weight(kg)
Units perbox
Units percarton
3P600V60A4P600V60A5P600V60A6P600V60A
6585
105125
0.210.260.320.38
1111
20202020
DH5623KDH5624KDH5625KDH5626K
Insulating piece UL Listed UL
Cat. No. Rating
1P300V1A
Weight(kg)0.01
Units perbox
1
Units percarton
50DH5681
Cat. No. Weight(kg)0.07
Units perbox
1
Units percarton
20DH5682K
※5P(DH5625K)
Used to mount the High-Tro-Reel units on the side of a rail. Can also be used with tension type units. Standard support interval is 400mm.
60
4025
25
13
96
109
Drawing shows a 5P hanger.φ6.5mm holes are not incorporated in 3P and 4P hangers.
※5P(DH5775K2)
Hanger UL Listed UL
Cat. No. Type
For 3PFor 4PFor 5PFor 6P
A
6989
109129
B
——6080
C
567696
116
Weight(kg)0.060.070.080.09
Units perbox20101010
Units percarton
100505050
DH5773K2DH5774K2DH5775K2DH5776K2
Line separator UL Listed
Used to separate circuits by creating an insulated section partway along the line.
25
A
2020
20
26
C
79
B
95
Drawing shows a 4P separator.
※5P(DH5665)
Cat. No. Type
For 4PFor 5P
A
86106
B
108128
C
97117
Weight(kg)0.200.23
Units perbox
11
Units percarton
1010
DH5664DH5665
UL
Used to separate circuits by providing an insulated section on the line.In addition to providing insulation between two circuits, it can also feed power of different voltages.
24
Unit:mm
Attached to the moving equipment and used to supply power from the High-Tro-Reel units to the equipment. Mount rod and mount plate types are available to fit mounting hardware.
Collector arms UL Listed UL
Used to guide the collector arms from one curved section to another via traversers. The end is a rear-facing 45° angle.
15.5
A
BC
20 20 20 20
56
26
17.535
Drawing shows a 5P guide cap.
Guide cap (withdrawn 45° cut) UL Listed UL
Used to guide the collector arms from one straight section to another via turntables and traversers. Can be used as an end cap.
35
ABC
20 20 20 20
26
Used to guide the collector arms from one curved section to another via traversers. The end is a front-facing45° angle.
15.5
ABC
20 20 20 2056
17.5
26
35
Drawing shows a 5P guide cap. Drawing shows a 5P guide cap.
Guide cap (right-angle cut) UL Listed UL Guide cap (protrusive 45° cut) UL Listed UL
Cat. No. Type
For 3PFor 4PFor 5PFor 6P
A
85105125145
B
7393
113133
C
6686
106126
Weight(kg)0.070.090.110.13
Units perbox1111
Units percarton30303030
DH5653DH5654DH5655DH5656
Cat. No. Type
For 3PFor 4PFor 5PFor 6P
A
85105125145
B
7393
113133
C
6686
106126
Weight(kg)0.070.090.110.13
Units perbox1111
Units percarton30303030
DH5643DH5644DH5645DH5646
Cat. No. Type
For 3PFor 4PFor 5PFor 6P
A
85105125145
B
7393
113133
C
6686
106126
Weight(kg)0.050.060.080.09
Units perbox1111
Units percarton30303030
DH5633DH5634DH5635DH5636
Length of lead wire 300A
※5P(DH5635) ※5P(DH5645) ※5P(DH5655)
R3.5-5S
74.5
8555
65±
10(R
ange
of m
ovem
ent)
6 75
20
30
15.5
(180
)
14.8
(180
)
R3.5-5S
30
170255
76
65±
10(R
ange
of m
ovem
ent)55
74.55
15.5
20
14.8
(180
)
R3.5-5S
17074.5
55
30
515.5
20
255
76
65±
10(R
ange
of m
ovem
ent)
14.8
R3.5-5S
6 7
5574.5
(180
)
19 6
0±10
(Ran
ge o
f m
ovem
ent)
70
515
●Single type (for mount rod) ●Single type (no saddle)
●Tandem type (for mount rod) ●Tandem type (for mount plate)
●Single type (for mount rod)
●Tandem type (for mount rod)
●Tandem type (for mount plate)
●Single type (no saddle)
Note: Does not include mount rod 12×12.
Note: Does not include mount plate for mounting.
Note: Does not include mount rod 12×12.
Cat. No. Type Rating Weight(kg)
Units perbox
Units percarton
Single (for mount rod)
Tandem (for mount rod)
Tandem (for mount plate)
Single (no saddle)
1P600V30A1P600V30A×21P600V30A×2
1P600V30A
0.140.230.230.11
1111
16161616
DH56901K1DH56911K1DH56912K1DH56920K1
The collector arms should be replaced when it wears down to the replacement indication line. Typical collector service life is approximately 20,000km.
25
HIGH-TRO-REEL (Non-Tension Type)
Units percarton
R3.5-5S
30
65±
10(R
ange
of m
ovem
ent)
(180
)
85
6 7
5574.5
515.5
14.8
20
(180
)
R3.5-5S
170
30
74.555 5
15.5
255
7665±
10(R
ange
of m
ovem
ent)
14.8
20
R3.5-5S(180
)
170 74.555 5
30
15.5
255
7665±
10(R
ange
of m
ovem
ent)
14.8
20
(180
)
R3.5-5S
19
70
74.555 5
15
60±
10(R
ange
of
mov
emen
t)
6 7
Collector arms (with flat connection terminals)
Collectors can be easily connected and disconnected to/from lead wires with just one motion. Mount rod and mount plate types are available to fit mounting hardware.Note: UL certification not yet obtained.
Cat. No. Type Rating Weight(kg)
Units perbox
Units percarton
Single (for mount rod)Tandem (for mount rod)
Tandem (for mount plate)Single (no saddle)
1P600V20A1P600V20A×21P600V20A×2
1P600V20A
0.140.230.230.11
1111
16161616
DH56931K1DH56941K1DH56942K1DH56950K1
Length of lead wire 300A
Length of lead wire 300A
●Single type (for mount rod) ●Single type (no saddle)
●Tandem type (for mount rod) ●Tandem type (for mount plate)
●Single type (for mount rod)
●Tandem type (for mount rod)
●Tandem type (for mount plate)
●Single type (no saddle)
Collector (replacement part)
Conductor cleaner
8.512
.57
5
30
65±
10(R
ange
of m
ovem
ent) 5
15
14.8
20
8085
Collector arm support hardware
Collector (with flat connection terminals; replacement part)
These components are mounted on the collector arm.They keep the arm horizontal and minimize uneven abrasion of the collector shoe.It is also possible to mount them on existing collector arms.
※Two units are required when mounting on the tandem type.
●Single type (no saddle)
●Tandem type and single type (for mount rod)
●Tandem type (for mount plate)
Cat. No.
Cat. No.
Cat. No.Rating
Type
Rating
1P600V30A
Single (for mount rod)
1P600V20A
Weight(kg)
Weight(kg)
Weight(kg)
0.06
0.12
0.12
Units perbox
Units perbox
Units perbox
10
1
10
Units percarton
Units percarton
100
16
100DH5683K3
DH56851K1
DH5684K2
Cat. No. Type
Single (no saddle)Tandem, Single (for mount rod)
Tandem (for mount plate)
Weight(kg)0.0130.0070.017
Units perbox121212
Units percarton
120120120
DH58870DH58871DH58872
Note: UL standards do not apply.
Note: This collector is a replacement part for using collector arms which are of an earlier type than the collector arms listed on page 25 of this catalog.
This nylon brush is used to clean the conductor surface of the High-Tro-Reel units.Note: UL standards do not apply.
Collectors can be easily connected and disconnected to/from lead wires with just one motion.Note: UL standards do not apply.Note: This collector is a replacement
part for using with collector arms which are of an earlier type than the collector arms listed on page 26 of this catalog.
Note: UL standards do not apply.
The collector arms should be replaced when it wears down to the replacement indication line. Typical collector service life is approximately 20,000km.
85
725
555
Replacementline
3.5-5S
8555 5
7626
300
Replacementline
26
HIGH-TRO-REEL (Non-Tension Type)