EXPLANATION OF GRAPHICAL SYMBOLS
CAUTIONS
CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER(OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTIONS
RISK OF ELECTRIC SHOCK DO NOT OPEN
2
WARNINGS
TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.
THE APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING
AND THAT NO DBJECTS FILLE WITH LIQUIDS, SUCH AS VASES,
SHALL BE PLACED ON THE APPARATUS.
The lighting flash with arrowhead symbol, within an triangle, is intended to alert the user
to the presence of uninsulated “dangerous voltage” within the product’s enclosure that
may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instruction in the literature
accompanying the appliance.
3
CE COMPLIANCE STATEMENT
FCC INFORMATION : THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS
FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE
DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE
EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES,
AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE
WITH THE INSTRUCTION MANUAL, MAY CAUSE HAARMFUL INTERFERENCE TO RADIO COMMUNICATIONS.
OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE
IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.
CAUTION : CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR
COMPLIANCE COULD VOID THE USER’S AUTHOURITY TO OPERATE THE EQUIPMENT.
THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES-003.
CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME NMB-003 DU CANADA.
WARNING
THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO
INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES.
4
* Please install the product on a completely flat floor.
- Always check the strength and stability of the installation location.
- Do not drop the appliacne on the floor. This may result in damage or injury.
* Do not attempt to disassemble the appliance. To prevent electric shock, do not remove
screws or covers.
- There are no user-servicecable parts inside. Contact qualified service personnel for
maintenance.
* Stop using the appliance if there appears to be any operational problem.
- Immediately turn the power off to the appliance if there is any abnormal condition such
as smoke or unusual smells.
- Continuing to use the appliance under abnormal conditions may result in serious damage.
* Always use the recommended power.
- Using incorrect power source ratings may result in fire, electric shock, or damage.
* Always handle the connection cable with care.
- Never damage or modify the connection cable.
- Do not pull, expose to heat, or place heavy objects on the connection cable.
- Non observance of these warnings may result in fire, electric shock or damage.
* Never use the appliance in places where there are flammable materials.
- Never use the appliance in places where flammable materials such as gas are used.
This may result in fire, explosion, and other serious accidents.
* Never touch un-insulated parts with wet hands.
- Touching un-insulated parts with wet hands may result in serious electric shock.
* Never expose the appliance to water or moisture.
- If the appliance gets wet, immediately turn the power off.
- Stop using the appliance if it gets wet. Contact the manufacturer immediately.
* Use the appliance indoors only.
- Do not place the appliance outdoors or expose it to rain or moisture.
- If dropped in water, the appliance may be corroded and damage.
* Do not use the appliance where there is excessive dust, smoke or moisture.
- Using the appliance under such conditions may result in fire, electric shock or
serious damage.
* If the controller body gets dirty, turn the power off and wipe the surface with a soft cloth
- Do not use chemical agents sudch as alcohol or benzene.
5
-WARNINGS AND CAUTIONS
-COMPLIANCE STATEMENT
-CE COMPLIANCE STATEMENT
-IMPORTANT SAFEGUARDS
- TABLE of CONTENT
- INTRODUCTION
- PACKAGE CONTENTS
- INSTALLATION & CONFIGURATION
--Basic configuration of Dome
--Rear View
--Swith Settings
--Before Installation
--Wall Mount Installation
--Ceiling Mount Installation
- External Interface
- DIMENSION
- SPECIFICATION
- OPERATION & PROGRAMMING
--Getting Started
--Basic Operations
--Title Edit
--Menu Tree
--System : Information
Reboot
Factory
Event Log
Password
--Display : OSD Setup
Area Title
Privacy Zone
Image Setup
--Dome : General
Motion
Home
Preset
Tour
Pattern
Scan
--Camera : Focus/Zoom
W - Balance
Exposure
Advanced Setup
--Alarm
- HOUSING & ACCESSORY
2
3
3
4
5
6
7
8
9
10
12
13
16
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
38
39
40
41
42
43
44
45
46
47
48
6
FEATURES
HIGH SPEED DOME
Lens
Power
Address Range
Preset
Tour
Pattern
Scan
Privacy Zone
Area Titles
Alarm
Protocol
Communication
Manual Speed
Preset Speed
Proportional Pan
36x, 26x, 18x Optical, 12x Digital
1/4 inch Sony EX-View HAD CCD
1~240 Position
8(Preset, Tour, Pattern and Scan)
8(Total 960 seconds)
8 including Vector Scan
32 zones (8 groups)
8
0.1 /sec ~ 360 /sec
Max 360 /sec
Yes
4 input(NO/NC)
Auto Protocol Recognition (Standard, Pelco-D, Pelco-P etc.)
RS-485 Half duplex. Max 4000 ft (1.2Km)
DC 12V (2.5V), AC 12V Optioal
99 ID (255 ID Optional)
The Controller and Mini Speed dome make up the building blocks for any surveillance / security system.
Using a multiple Controller and multiple dome cameras, no place is too large for monitoring and recording.
Extendable and flexible architecture facilitates remote control functions for a variety of external switching
devices such as DVR, Matrix switcher and Dome Camera.
Precautions for proper Operation
* Do not install the unit a place subject to direct sunlight, excessive moisture, dust or vibrations
where ventilation is poor.
* Please use the unit in the range of a guarantee temperature and humidity of operation.
* Please set ID of a camera as the same number as the input channel to DVR or Matrix switcher.
7
1. Dome camera Unit
2. Body (W/O Sunshield)
3. Trimring Bubble Dome
4. Wrench-3mm
5. User’s manual
OPTION
1. Wall Pipe Bracket
2. Ceiling pipe Bracket
3. Set Anchor(8 SET)
4. Sunshield
The following parts are supplied with the mini speed dome system.
Option
Wall Ceiling
8
Basic Configuration of Dome
Master Slave
CAM : 001 BAND
INPUT ? :
CAM : 001 BAND
INPUT ? :
T IN TC OL ORB RIG HTC ON T V1VO LU MEU ND ERS C AN S� VI DE O PO WE RV 2PM C 14H
9
Rear View
1 Pin description
2 Dip switch for protocol and band rate
3 Address switch
4 Alarm in/out
DC
On
ly
10
SWITCH SETTINGS
Before installation, please set the switches as described in this manual.
< Figure 1. Switches >
Protocols:
If you are going to use pelco-D, pelco-P protocols to communicate with the dome
system, you do not have to set any switches. The unit automatically detects these protocols. See Table A
for details.
<Table A. Protocols >
Switch1 Switch 2 Protocols
Off Off Pelco-D , Pelco-P, etc. Auto detect.
Off On Reserved
On Off Reserved
On On Reserved
DC Only
11
Baud rate:
Termination:
Default baud rate is 2400 bps. See Table B for details.
<Table B. Baud rate>
<Table C. Baud rate>
Switch 3 Switch 4 Baud rate (bps)
Off Off 2400 *default
Off On 4800
On Off 9600
On On 38400
See Table C for details.
Switch 5 Termination
Off Not Terminated
On Terminated
High Speed Dome system supports termination free RJ45 impedance matching.
12
remove the pan/tilt set screw
BEFORE INSTALLATION
Before installation, please remove the pan/tilt holder screw. Use the following steps.
1. Disassemble the 4 screws fixed in trimring.
2. Remove the fixed pan / tilt screws.
<Figure 2>
<Figure 3>
1. Disassemble the 4 fixed set screws.
2. Assemble RJ-45 cable.
3. Connect the alarm connector as this picture.
DC
On
ly
13
WALL MOUNT INSTALLATION
* Fix the TP 18 x 30L Screw supplied as the <Figure 4>
<Figure 4>
<Figure 5>
* Pass the cables through the bottom of the bracket.
21
14
* Hang the safety hook against drop on the bracket.
<Figure 6>
<Figure 7>
* Put the dome cable into the bracket and fix it.
15
* Fix the camera set by turning it clockwise as this picture.
(Notice : the cable against drop can be twisted)
* After coupling, fix the screws against ravelling by the wrench
supplied, complete it by molding of waterproof silicon
* Connect the camera set cable and the bracket cable, and put them into the bracket.
* Fix the steel cover supplied on the upper part of the bracket and complete fixing it by the
screw CM3 x 8L
<Figure 9>
<Figure 8>
16
* Fix the plastic anchors on the roof as this figure and fix the ceiling using the
screws supplied.
<Figure 10>
<Figure 11>
* Fix the pipe supplied as this figure turning it clockwise.
CEILING MOUNT INSTALLATION
17
* Hang the hook against drop on the ceiling bracket as this
figure, connect the camera set and the bracket cable and
fix it turning the camera set clockwise.
<Figure 12>
<Figure 13>
* Assemble the fixed screws using the wrench supplied
by molding of waterproof silicon as described in figure.
18
<Figure 14.1> with Sunshield <Figure 14.2> without Sunshield
19
Wire Gauge
<Table D> Interface Cable Wiring
<Table E Video Coaxial Cable Requirements>
Pin Color Function
1 WHITE/ORANGE VIDEO
2 ORANGE V-GND
3 WHITE/GREEN AC-/GND
4 BLUE DC/ +12V
5 WHITE/BLUE DC/ +12V
6 GREEN AC-/GND
7 WHITE/BROWN TRX-
8 BROWN TRX+
Cable Type Maximum Distance
RG 59/U 750 ft (229m)
RG 6/U 1,000ft (305m)
RG 11/U 1,500ft (457m)
* Cable requirement : 75-ohm impedance.
* All-copper center conductor.
* All-copper braided shield with 95% braid coverage
The following are the recommended maximum distances for 24 VAC applications and
are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum
allowable voltage drop for AC-powered devices.
Power consumption is 21 VA per unit. Use a power source with a minimum of 21 VA per unit.
<Table F Wiring Distances>
Voltage 18 16 14 12
(1.0mm)
24VAC 215ft 341ft 542ft 863ft
DC
On
ly
External Interface (RJ-45)
20
DOME
WALL
CEILING
21
Camera
Image Sensor
Zoom (Model Specific)
Min Focus Distance
Scanning System
Frequency
Resolution
S/N Ratio
Video Output Signal
Minimum Illumination
Day & Night
White Balance
Video Output
Dome
Pan Angle / Speed
Tilt Angle / Speed
Preset Speed
Preset
Guard Tour
Pattern
Communication
Protocol
Auto Scan
Dome ID
Screen Display
General
Certification
Power Source
Operating Temperature
Operating Humidity
Material
Color
Dimension
Weight
1/4 - type Sony EX-View HAD CCD
36x Optical, f=3.4 to 122.4mm (F1.6~F4.5)
26x Optical, f=3.5 to 91.0mm (F1.6~F3.8)
18x Optical, f=4.1 to 73.8mm (F1.4~F3.0)
12x Digital Zoom
320mm(36x), 320(26x), 290(18x)
2:1 Interlace
NTSC : 15.734KHZ(H), 59.94HZ(V)
PAL : 15.625KHZ(H), 50HZ(V)
NTSC(Wide) : 530TV Lines(Min)
PAL (Wide) : 530TV Lines(Min)
More than 50dB
VBS 1.0V~p-p Composite (750hm Load)
0.1 Lux(36x), 0.09Lux(26x), 0.07Lux(18x) with ICR OFF
0.01 Lux with ICR ON
On, Off
Auto, ATW, Indoor, Outdoor, One-Push, Manual
CVBS : 1.0Vp-p / 75
360 Continuous Rotation, 0.1 ~360 / sec
-2 ~ 182 , 0.1 ~ 360 / sec (According to Zoom Speed)
Max. 360 /sec
1~240 Preset
8 Guard Tour (Preset, Pattern, Auto Scan, Tour Input)
8 Pattern, 960sec Memory
RS-485 Baud Rate : 2400 (Default) / 4800/9600/38400
Pelco-P, Pelco-D, Standard
8 Auto Scan
1~255 Camera ID
Camera ID, Pan / Tilt Angle, Flip, Zoom
CE, FCC, VCCI, ROHS, IP67
DC12V 2.5A (AC24V Optional)
-40 C~ 60 C (-40 F ~140 F)
0~90% RH (Non-Condensing)
Polycarbonate Bubble Dome / Aluminum Main Body. Vandal-Proof
Ivory / Black
233 x 235
Approx. 2200g
22
GETTING STARTED
This manual is designed to be a reference tool for the installation, programming and
operation of your system.
You need to install you system before using this manual. Refer to <installation> part
of this manual.
Once installed, apply power to the dome. The system will start a configuration sequence.
This information will remain on the monitor until dome operation begins. Refer to the following pages
to operate and program your dome system.
Note
1. Version can be changed by system upgrade.
2. Address changes with respect to ‘address switching setting’
3. Temperature can be changed by outside environment.
4. This manual is written by using E-ronix controller (ESC-200J)
23
Basic Operations
How to Control
Pan and Tilt Move joystick or press the direction keys left/right and up/down.
* Zoom Tele To zoom far, do the following:
1. Press the [TELE] button or turn the joystick clockwise until zoom stops at the 100X zoom limit
2. Release the button or joystick for one second.
3. To continue zooming (digitally), press the button or turn the joystick clockwise again until you
have the picture you want or reach the digital zoom limit.
* Zoom Wide Press the [WIDE] button or turn the joystick counterclockwise.
Preset Refer to <Preset> part of this manual.
Tour Refer to <Tour> part of this manual.
Pattern Refer to <Pattern> part of this manual.
Scan Refer to <Scan> part of this manual.
Privacy Zones Refer to the Zones section and to the documentation supplied with the control system.
24
ACCESSING MAIN MENU (Menu/Preset 95)
When you use PD or PP protocol with your controller, you can access the main menu
by programming (saving or calling) preset 95.
When you use STANDARD or any other protocols, do the followings:
1. Enter the number of the dome and press the CAM key.
2. Press the MENU key. The main menu appears.
To edit a title:
1. Use the joystick to position the cursor beside TITLE.
2. Move the joystick right. The following appears on the monitor.
3. Use the joystick right, left, up and/or down to select a character. Press [TELE] button or twist
the joystick clockwise to input a character.
4. Press [WIDE] button or twist the joystick counterclockwise to delete a character.
5. Follow the directions displayed on the monitor.
6. When the label is completed, press [ENT] or [IRIS OPEN] to return to the previous menu.
7. To cancel editing a title, press [CLR] or [IRIS CLOSE] to return to the previous menu.
TITLE:
ABCDEFGHIJKLMNOP
QRSTUVWXYZabcdefg
hijklmnopqrstuvwx
yz0123456789<>/-:
■ Select: <MOVE>
■ Save: <ENT> <OPEN>
■ Exit: <CLR> <CLOSE>
TITLE EDIT
*This title edit menu can be used in OSD Setup/Pattern/Scan/Preset/Area Title commonly.
25
MENU TREE
SYSTEM
DISPLAY
DOME
CAMERA
ALARM (p.47)
EXIT
OSD SETUP (p.31)
AREA TITLES (p.32)
PRIVACY ZONE (p.33)
IMAGE SETUP (p.34)
FOCUS/ZOOM (p.43)
W-RALANCE (p.44)
EXPOSURE (p.45)
ADVANCED (p.46)
INFO (p.26)
REBOOT (p.27)
FACTORY (p.28)
EVENT LOG (p.29)
PASSWORD (p.30)
GENERAL (p.35)
MOTION (p.36)
PRESET (p.38)
TOUR (p.40)
PATTERN (p.41)
SCAN (p.42)
26
SYSTEM: INFO
The system Information displays serial number/model name/ Running
version/Protocol/Communication Type/Address switch No./Temperature.
System settings cannot be edited in this menu. This screen
is for reference only.
Use the following steps to display the system information screen:
1. Push the MENU key(refer to ‘Accessing main menu’in page 38)
2. Use the joystick to position the cursor beside SYSTEM.
3. Move the joystick right.
4. Select INFO using joystick.
Note
-Version can be changed by system upgrade.
-Address changes with respect to ‘address switching setting’
-Temperature can be changed by outside environment.<< SYSTEM INFORMATION >>
██████████████████████████S/N:0-00-00-000-00000MODEL : XXX-XXXXVERSION : XXX-XXXXVIDEO : 1.58EMPROTOCOL : STANDARDCOMM. : RS485/02400ADDRESS : 001TEMP. : 044.0C/111.2F██████████████████████████■ Exit: <CLR> <CLOSE>
██████████████████████████►SYSTEM > INFO
DISPLAY > REBOOTDOME > FACTORYCAMERA > ALARMEXIT
<<<<< Main MENU >>>>>
██████████████████████████►SYSTEM >
DISPLAY >DOME >CAMERA >ALARMEXIT
<<<<< Main MENU >>>>>
27
SYSTEM: Reboot
Reboot the system if it does not operating or if it is not available
for control.
Rebooting the system will cycle power without changing
programmed dome settings.
Use the following steps to display the System Information screen:
1. Press the MENU key(refer to ‘Accessing main menu’ in page 38)
2. Select SYSTEM using joystick.
3. Select REBOOT using joystick in the sub menu of SYSTEM.
4. To Reboot the system, Press [ENT] or [OPEN].
To cancel reboot, Press [CLR] or IRIS [CLOSE] key.
■ Reboot: <ENT> <OPEN>■ Exit: <CLR> <CLOSE>
██████████████████████████►SYSTEM > INFODISPLAY > ►REBOOTDOME > FACTORYCAMERA >ALARMEXIT
██████████████████████████►SYSTEM >
DISPLAY >DOME >CAMERA >ALARMEXIT
<<<<< Main MENU >>>>>
<<<<< Main MENU >>>>>
28
SYSTEM: FACTORY
Use this function to reset all camera settings to factory default parameters.
You can reset a specific setting to factory default parameters.
Use the following steps to display the System Information screen:
1. Press the MENU key (refer to ‘Accessing main menu’ in page 38)
2. Select SYSTEM using joystick.
3. Select FACTORY in the sub menu of SYSTEM using joystick.
4. Select items to be reset.
5. Press [ENT] button or move the cursor to<SAVE and exit>
and then move the joystick right.
ALL: Restores all save items (CAM/PRESET/TOUR/PATTERN/
SCAN settings)
CAM: Reset Camera related settings.
PRESET: Reset Saved presets.(To reset specific preset, refer to
Preset PRESET in chapter 35)
TOUR: Reset Saved Tours.
PATTERN: Reset Saved pattern.
SCAN: Reset Saved Scan items.
██████████████████████████►SYSTEM > INFO DISPLAY > REBOOTDOME > ►FACTORY CAMERA > ALARM EXIT
██████████████████████████►SYSTEM >
DISPLAY >DOME >CAMERA >ALARM EXIT
<<<<< Main MENU >>>>>
<<<<< Main MENU >>>>>
<< FACTORY SETUP >>██████████████████████████►ALL : OFF
CAM : OFF PRESET : OFF TOUR : OFF PATTERN : OFF SCAN : OFF██████████████████████████ <Save and Exit> <Exit without Saving>
29
SYSTEM: EVENT LOG
Event Log shows the current dome status and dome event logs.
If the dome have some problems, it displays error signal and save
the logs to EEPROM. Turn SELF TEST on to monitor the dome’s
status and save all event logs. See <DOME:GENERAL> for
SELF TEST descriptions.
Use the following steps to display the EVENT LOG screen:
1. Press the MENU key (refer to ‘Accessing main menu’ in page 38)
2. Select SYSTEM using joystick.
3. Select EVENT LOG in the sub menu of SYSTEM using joystick.
4. Code : <number> means number of error occurred during
camera operation.
When you scroll up and down using joystick, you can find what
kinds of error have occurred during operation.
5. Press the [ESC] or [IRIS CLOSE] key to return previous menu.
<<<<< Main Menu >>>>>██████████████████████████►SYSTEM > DISPLAY > DOME > CAMERA > ALARM EXIT
<<<<< Main Menu >>>>>██████████████████████████►SYSTEM > INFO. DISPLAY > REBOOT DOME > FACTORY CAMERA > ►EVENT LOG ALARM PASSWORD EXIT
<<<< EVENT LOG >>>>██████████████████████████Code:0000,Cnt:00,Drp:000Current Status-----------------------
██████████████████████████Exit: <CLR> <CLOSE>
<<<< EVENT LOG >>>>██████████████████████████Code:0000,Cnt:00,Drp:000
None............
-----------------------
►01.00 Empty........... 02.00 Empty........... 03.00 Empty........... 04.00 Empty........... 05.00 Empty...........██████████████████████████Exit: <CLR> <CLOSE>
30
SYSTEM: PASSWORD
Use this function to
The dome features password protection to prevent unauthorized
changes to the dome settings. An operator cannot access any of
the Dome Settings menus.
Controller/keyboard commands cannot override password-protected
settings. If a keyboard is used to set a preset, pattern, or zone,
the Enter Password screen appears on the monitor.
The password must be entered before programming can continue.
Four characters must be entered to create a valid password.
Use the following steps to set up password:
1. Press the MENU key (refer to ‘Accessing main menu’ in page 38)
2. Select SYSTEM using joystick.
3. Select PASSWORD in the sub menu of SYSTEM using joystick.
4. Select number using joystick left/right and press the TELE key
or twist joystick.
clockwise to input. Repeat this action to fill current/new/confirm
password.
5. To enable password set ENABLE:ENABLED
Note
-The default password is “0000”
-When you initialize the system with <SYSTEM:FACTORY>,
password will be removed.
<<<<< Main Menu >>>>>██████████████████████████►SYSTEM > DISPLAY > DOME > CAMERA > ALARM EXIT
<<<<< Main Menu >>>>>██████████████████████████►SYSTEM > INFO. DISPLAY > REBOOT DOME > FACTORY CAMERA > EVENT LOG ALARM ►PASSWORD EXIT
PASSWORD██████████████████████████ ►CURRENT: x--- NEW : ---- CONFIRM: ---- ENABLE : DISABLED██████████████████████████ x12456789
31
DISPLAY: OSD SETUP
OSD setup allows you to program how labels are displayed onthe monitor.
The following labels are available:TITLE Identifies area and operation titles.TIME Identifies dwell time.ZOOM Identifies the amount of magnification.ID Identifies dome address.MODE Identifies dome operation mode.ANGLE Amount of pan/tilt from 0°.
The zoom ratio label is displayed when zoom is activated.The following settings are available for each label:OFF Label is not displayed when activated.ON The label is continually displayed.xx SEC The label is displayed for xx seconds after activation.
Labels can be placed anywhere on the monitor. This feature allows you to customize the appearance of your monitor screen.
To set a label position:1. Press the MENU key (refer to ‘Accessing main menu’ in page 38).2. Select DISPLAY and select OSD SETUP using joystick.3. Press the [TELE] button or turn the joystick clockwise.4. Use the joystick to move the label up, down, left and/or right.5. Press [ENT] or [IRIS OPEN] key.6. Repeat steps 1 through 4 to position other labels.7. Select <Save and Exit> to save settings and exit menu.8. Select <Exit without Saving> to exit menu without saving settings.
*Note -Press [ENT] or [IRIS OPEN] key to save settings and exit to previous menu. Press [Esc] or [IRIS CLOSE] key to go to previous menu without saving any settings at any time.
██████████████████████████SYSTEM > ►DISPLAY > ►OSD SETUP DOME > AREA TITLES CAMERA > PRIVACY ZONE ALARM IMAGE SETUPEXIT
██████████████████████████SYSTEM >►DISPLAY >
DOME > CAMERA > ALARM EXIT
████████████████████████
<<<<< Main MENU >>>>>
<<<<< Main MENU >>>>>
<< OSD SETUP >>██████████████████████████►TITLE : OFF
TIME : OFF ZOOM : 3 SEC ID : ON MODE : ON ANGLE : 3 SEC██████████████████████████ <Save and Exit> <Exit without Saving>
Twist joystick clockwise
or press [TELE] button
32
█ Start Position Setup
█ Press MOVE Key█ Save: <ENT> <OPEN>█ Exit: <CLR> <CLOSE>
██████████████████████████SYSTEM > ►DISPLAY > OSD SETUPDOME > ►AREA TITLESCAMERA > PRIVACY ZONEALARM IMAGE SETUPEXIT
DISPLAY: AREA TITLES
A zone is a pan area, defined by a left and right limit on the pan plane.
The dome system is capable of 8 area titles, each with a 12 character
label
To program a zone:
1. Press the MENU key(refer to ‘Accessing main menu’ in page 38)
2. Select DISPLAY and select AREA TITLE usig joystick.
3. Use the joystick to position the cursor beside NO.xxx. Move left or
right to select zone ID. Press the [TELE] button or turn the joystick
clockwise to setup START and STOP pan limit angle.
4. Move the joystick to position start limit angle, Press [ENT] or
[IRIS OPEN] to save START limit angle.
5. Move the joystick to position start limit angle, Press [ENT] or
[IRIS OPEN] to save STOP limit angle.
6. Edit a title, See [TITLE EDIT] section for detail.
To clear an area title:
1. Press the MENU key (refer to ‘Accessing main menu’in page 38)
2. Select DISPLAY and select AREA TITLE using joystick.
3. Use the joystick to position the cursor beside NO.xxx.Move left or
right to select zone ID.
4. Press the [WIDE] or turn the joystick counter clockwise to clear
area title.
*Note
- after saving area titles, turn on the TITLE menu in the
<DISPLAY:OSD SETUP> to view the area title.
*Note
- Press [ENT] or [IRIS OPEN] key to save settings and exit
to previous menu. Press [Esc] or [IRIS CLOSE] key to go to
previous menu without saving any settings at any time.
<< AREA TITLE SETUP >>██████████████████████████►NO.001 : █ TITLE : -START : -STOP : ██████████████████████████ <Save and Exit> <Exit without Saving>
<<<<< Main MENU >>>>>
Twist joystick clockwise
or press [TELE] button
33
Twist joystick clockwise
or press [TELE] button
DISPLAY: PRIVACY ZONE
A privacy zone allows a user to program one four-sided, user-defined
area that cannot be viewed by the operator of the dome system. The
blanked area will move with pan and tilt functions and automatically
adjust in size as the lens zooms telephoto and wide
1.Group no : Identifies group ID. Can have 1~8
2. No. xxx : Identifies privacy zone ID. Can have 1~4
3. Mode : DSABLE - disable privacy zone
BLOCK - Enable privacy zone
4. Privacy Mask : adjust mask size
3-1 : PAN/TILT - adjust position
3-2 : TELE - enlarge mask size
3-3 : WIDE - make mask size small
To program a privacy zone:
1. Press the MENU key (refer to ‘Accessing main menu’ in page 38)
2. Select DISPLAY and select PRIVACY ZONE using joystick.
3. Use the joystick to position the cursor beside NO.xxx. Move left or
right to select zone ID. Press the [TELE] button or turn the joystick
clockwise to setup a zone.
4. Follow the instructions that appear on the screen.
5. The Privacy Zone menu reappears with a saved marked (█) option.
To disable or clear a Privacy Zone (a zone is enabled automatically
when it is programmed):
1. Use the joystick to position the cursor beside NO.xxx.Move left or
right to select zone ID.
2. Press the [WIDE] button or turn the joystick counterclockwise to clear.
*NOTE Press [ENT] or [IRIS OPEN] key to save settings and exit
to previous menu or Press [Esc] or [IRIS CLOSE] key to go to
previous menu without saving any settings at any time.
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > ►DISPLAY > OSD SETUP DOME > AREA TITLES CAMERA > ►PRIVACY ZONE ALARM IMAGE SETUP EXIT
<< PRIVACY ZONE SETUP >>██████████████████████████ GROUP : 1►NO.001 : █ MODE : DISABLE██████████████████████████ <Save and Exit> <Exit without Saving>
█ Press MOVE Key█ Save: <ENT> <OPEN>█ Exit: <CLR> <CLOSE>
34
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > ►DISPLAY > OSD SETUP DOME > AREA TITLES CAMERA > PRIVACY ZONE ALARM ►IMAGE SETUP EXIT
<< IMAGE SETUP >>██████████████████████████►MIRROR : OFF██████████████████████████ <Save and Exit> <Exit without Saving>
DISPLAY: IMAGE SETUP
This menu allows operator to change of displayed image settings
The following four options are available:
OFF normal image
H.MIRROR left-right reversal image
V.MIRROR upside-down image
REVERSE left-right reversal and upside-down image
To set up image display
1. Press the MENU key (refer to ‘Accessing main menu’ in page 38)
2. Select DISPLAY and select IMAGE SETUP using joystick.
3. Select one of four possible settings.
*Note
-Press [ENT] or [IRIS OPEN] key to save settings and exit
to previous menu. Press [Esc] or [IRIS CLOSE] key to go to
previous menu without saving any settings at any time.
35
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > ►GENERAL►DOME > MOTION CAMERA > HOME ALARM PRESET EXIT TOUR PATTERN SCAN
<< GENERAL SETUP >>██████████████████████████►BACKUP TASK : ON
TURBO SPEED : OFF PRESET SPEED: FAST SELF TEST : OFF UNIV. DWELL : OFF██████████████████████████ <Save and Exit> <Exit without Saving>
DOME: GENERAL SETUP
This menu control general dome related function.
Detail description is as follow.
BACKUP TASK
Dome ID is generally assigned with address switch, but using this
menu you can assign the dome ID with S/W.
BACKUP TASK
This setting defines a specific(preset, tour, pattern and scan) activity
to be performed in the event the power to the dome is cycled or after
alarm action.
The following settings are available:
OFF No action.
ON (default) The dome resumes its prior activity.
TURBO SPEED
This setting defines the manual pan and tilt speed.
The following settings are available:
OFF (default) Max speed is 90 degrees per second.
ON Max speed is 400 degrees per second.
*Note- Turbo speed only applicable to manual operation
not for preset, pattern etc.
PRESET SPEED
You can optimize preset speed with this menu.
There are three options:
FAST : 400 deg / sec
NORMAL : 300 deg / sec
SLOW : 200 deg / sec
SELF TEST
This setting defines the diagnostic monitoring activity.
When the dome finds some problems, the error signal is displayed.
For details, see <SYSTEM:EVENT LOG> section in this manual.
The following settings are available:
OFF (default) Disable selftest
ON Enable selftest
UNIV. DWELL(UNIVERSAL DWELL TIME)
Set the dome’s dwell time universally regardless of setting dwell time of any other activity (preset, scan etc.)
OFF Disable universal swell time
3~239 set the universal dwell time with this value.
36
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > GENERAL►DOME > ►MOTION CAMERA > HOME ALARM PRESET EXIT TOUR PATTERN SCAN
<< MOTION SETUP >>██████████████████████████►PROP. PAN/TILT: ON AUTO FLIP : ON OVER TILT : ON AZIMUTH ZERO : OFF LIMIT STOP : OFF -LEFT LIMIT : -RIGHT LIMIT :██████████████████████████ <Save and Exit> <Exit without Saving>
DOME: MOTION
PROPORTIONAL PAN/TILT
Proportional pan/tilt automatically reduces or increases the pan and
tilt speeds in proportion to the amount of zoom. At telephoto zoom
settings, the pan and tilt speeds will be slower for a given amount of
joystick deflection than at wide zoom settings.
There are two proportional pan/tilt modes:
ON (default) Enables the proportional pan/tilt mode.
OFF Disables proportional pan/tilt mode. The pan/tilt speed will not
depend on the amount of zoom.
AUTO FLIP
When the camera tilts downward and goes just beyond the vertical
position, the dome rotates 180 degrees. When the dome rotates
(flips), the camera starts moving upward as long as you continue to
hold the joystick in the down position. Once you let go of the joystick
after the dome rotates, joystick control returns to normal operation.
ON (default) Auto flip mode is enabled.
OFF Auto flip mode is disabled.
OVER TILT
To prevent horizontal view cut with trim ring or ceiling, this menu restrict
horizontal view angel.
ON restrict minimum tilt angle to 4.5 degree
OFF minimum tilt angel is 0 or below 0.
AZIMUTH ZERO
Azimuth zero is the pan angle from 0° to 359°. Azimuth zero is the pan
position you specify to be the 0° point. Azimuth zero is normally set to
magnetic north. Once set, azimuth is based on the set Azimuth zero
point.
To set Azimuth zero:
1. Use the joystick to position the cursor beside AZIMUTH ZERO.
2. Press [TELE] or twist the joystick clockwise.
3. Follow the directions displayed on the monitor.
To clear Azimuth zero:
1. Use the joystick to position the cursor beside AZIMUTH ZERO.
2. Press [WIDE] or twist the joystick counterclockwise.
37
DOME: MOTION
LIMIT STOP
Limit stops are programmable stops that limit the pan range of the dome.
There must be two limits, a left and a right, to define an area. A manual
(joystick) pan operation stops when a limit stop is reached.
To set limit stops:
1. Use the joystick to position the cursor beside LIMIT STOP.
2. Press [TELE] or twist the joystick clockwise.
3. Follow the directions displayed on the monitor.
To clear limit stops, set limit stop mode to OFF.
1. Use the joystick to position the cursor beside LIMIT STOP.
2. Press [WIDE] or twist the joystick counterclockwise.
<< MOTION SETUP >>██████████████████████████ PROP. PAN/TILT: ON AUTO FLIP : ON OVER TILT : ON AZIMUTH ZERO : OFF►LIMIT STOP : OFF -LEFT LIMIT : -RIGHT LIMIT :██████████████████████████ <Save and Exit> <Exit without Saving>
38
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > GENERAL►DOME > MOTION CAMERA > ►HOME ALARM PRESET EXIT TOUR PATTERN SCAN
<< HOME SETUP >>██████████████████████████►ACTION : HOME
NUMBER : TIME : 120 min MODE : AUTO██████████████████████████ <Save and Exit> <Exit without Saving>
DOME: HOME
This feature defines what activity should be executed after assinged
idle time.
ACTION / NUMBER
HOME (default) HOME action.
PRESET [NUMBER] Dome goes to preset [NUMBER].
TOUR [NUMBER] Runs tour [NUMBER].
PATTERN [NUMBER] Dome starts pattern [NUMBER] .
SCAN [NUMBER] Dome goes to scan [NUMBER].
*Note
-In order to call action preset, tour, pattern or scan, you must save
preset, tour, pattern or scan first.
TIME
This feature allows the dome to begin a user specific action after a
programmed time of inactivity. Home time can be programmed from
1 minute to 240 minutes (4 hours).
MODE
AUTO (default) Enabled HOME function.
MANUAL Disables this feature.
39
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > GENERAL►DOME > MOTION CAMERA > HOME ALARM ►PRESET EXIT TOUR PATTERN SCAN
<< PRESET SETUP >>██████████████████████████►NO.001 : Empty
TITLE : DWELL : -PTZ : ██████████████████████████ <Save and Exit> <Exit without Saving>
DOME: PRESET
The dome system has 240 preset positions. Each of the user-definable
presets can be programmed to use pan, tilt and camera settings.
Use the following steps to program a preset.
1. Use the joystick to position the cursor beside NO.xxx. Move left or
right to select preset ID.
2. Press the [TELE] button or turn the joystick clockwise to edit a
preset scene.
3. Follow the directions displayed on the monitor.
4. The PRESET SETUP menu reappears with a Saved option.
5. Edit a title. See [TITLE EDIT] section for details.
6. Edit a dwell time.
To clear a preset:
1. Use the joystick to position the cursor beside NO.xxx. Move the
joystick left or right to select a preset ID.
2. Press the [WIDE] button or turn the joystick counterclockwise to
clear a preset.
*NOTE Press [ENT] or [IRIS OPEN] key to save settings and exit
to previous menu. Press [Esc] or [IRIS CLOSE] key to go to
previous menu without saving any settings at any time.█ Start Position Setup
█ Press MOVE Key█ Save: <ENT> <OPEN>█ Exit: <CLR> <CLOSE>
40
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > GENERAL►DOME > MOTION CAMERA > HOME ALARM PRESET EXIT ►TOUR PATTERN SCAN
<< TOUR SETUP >>██████████████████████████►NO.001 : Empty
=== === === === === ===
=== === === === === ===
=== === === === === ===
=== === === === === ===
=== === === === === ===
██████████████████████████ <Save and Exit> <Exit without Saving>
DOME: TOUR
The dome system has 8 guard tours. Each of the tour has 30 items.
Each item can have pre-defined preset, pattern, scan and any other tour.
To program a tour.
1. Press the MENU key (refer to ‘Accessing main menu’ in page 38).
2. Select DOME and select Tour using joystick.
3. Use the joystick to position the cursor beside NO.xxx. Move left or
right to select tour ID. Press the [TELE] button or turn the joystick
clockwise to setup.
4. To insert items. use following steps:
a. Move the joystick to position the cursor beside XXX.
b. Press the [TELE] button or turn the joystick clockwise to select an
action (PRESET, TOUR, PATTERN and/or SCAN) and number.
5. Follow the directions displayed on the monitor.
6. Before select a specific item, save it first.
To disable or clear a tour.
1. Use the joystick to position the cursor beside NO. xxx. Move left or
right to select tour ID.
2. Press the [WIDE] button or turn the joystick counterclockwise to clear.
41
DOME: PATTERN
A pattern is a memorized, repeating, series of pan, tilt, zoom and preset
functions that can be called with a command from a controller or
automatically by a programmed function.
The dome system can have maximum 8 user-defined patterns.
To program a pattern:
1. Press the MENU key (refer to ‘Accessing main menu’ in page 38).
2. Select DOME and select PATTERN using joystick.
3. Use the joystick to position the cursor NO.xxx. Move left or right
to select pattern ID.
4. Press the [TELE] button or turn the joystick clockwise to start to learn.
5. Follow the directions displayed on the monitor.
6. To finish learning, press [ENT] or [IRIS OPEN] key.
To cancel learning, press [CLR] or [IRIS CLOSE] key.
7. Edit title. Refer to [TITLE EDIT] section in this manual.
To clear a pattern:
1. Use the joystick to position the cursor beside NO.xxx. Move the
joystick left or right to select a pattern ID.
2. Press the [WIDE] key or turn the joystick counterclockwise.
*You can access this pattern setting menu with [PTRN] key in ESC-200J controller.
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > GENERAL►DOME > MOTION CAMERA > HOME ALARM PRESET EXIT TOUR ►PATTERN SCAN
<< PATTERN SETUP >>██████████████████████████►NO.001 : █ TITLE : -TIME : ██████████████████████████ <Save and Exit> <Exit without Saving>
42
DOME: SCAN
Scan is a pan and tilt functions from one point to another point.
The dome has 8 user-defined auto scans.
To program a scan:
1. Press the MENU key (refer to ‘Accessing main menu’ in page 38).
2. Select DOME and select PATTERN using joystick.
3. Use the joystick to position the cursor beside NO.xxx. Move left or
right to select a scan number.
4. Press the [TELE] key or turn the joystick clockwise to start to
setup start and stop position.
5. Edit a title. Refer to [TITLE EDIT] section in this manual.
6. Select scan speed. Scan speed is the degrees per second that
the dome will pan when in a scan mode. The range of scan speed is
from 1 to 9 the default value is 5.
*When the start and stop position are same, scan mode is changed to
ENDLESS automatically. Any other case, the mode is
COMING & GOING
To clear a scan:
1. Use the joystick to position the cursor beside NO.xxx. Move the
joystick left or right to select a scan number.
2. Press the [WIDE] key or turn the joystick counterclockwise.
How to activate a scan
Press the specific number key and then press [SCAN]. ex) [1]+[SCAN]
You can also access this menu with [SCAN] key.
*Note
Press [ENT] or [IRIS OPEN] key to save settings and exit
to previous menu or Press [Esc] or [IRIS CLOSE] key to go to
previous menu without saving any settings at any time.
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > GENERAL►DOME > MOTION CAMERA > HOME ALARM PRESET EXIT TOUR PATTERN ►SCAN
<< SCAN SETUP >>██████████████████████████►NO.001 : █ TITLE : SPEED : 5 DWELL : 005 sec. -MODE : -START : -STOP :██████████████████████████ <Save and Exit> <Exit without Saving>
43
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > DOME > ►FOCUS/ZOOM►CAMERA > W-BALANCE ALARM EXPOSURE EXIT ADVANCED
<< FOCUS/ZOOM SETUP >>██████████████████████████►FOCUS : TRIGGER
AF.SENSI : NORMAL D.ZOOM : ON██████████████████████████ <Save and Exit> <Exit without Saving>
CAMERA: FOCUS/ZOOM
FOCUS
There are three auto focus settings:
AUTO If auto focus mode is set to auto. The camera will focus
automatically.
MANUAL Focus is operated manually. To focus, press [NEAR] or
[FAR] key on the controller.
TRIGGER (default) If auto focus mode is set to TRIGGER, the camera
will focus when zoom functions.
*Note
Auto focus will malfunction at below condition.
- very dark or shiny area
- when slow shutter is activated
- area which doesn’t have contrast difference
AF.SENSI (Auto Focus Sensitivity)
AF sensitivity can be set to either Normal or Low.
NORMA Reaches the highest focus speed quickly. Use this when
shooting a subject that moves frequently. Usually this is the most
appropriate mode.
LOW Improves the stability of the focus. When the lighting level is low,
the AF function does not take effect, even though the brightness varies,
contributing to a stable image.
D. ZOOM(Digital Zoom)
To enable digital zoom, set D.ZOOM to ON.
The default value is ON.
*Note
Press [ENT] or [IRIS OPEN] key to save settings and exit to previous menu.
Press [Esc] or [IRIS CLOSE] key to go to previous menu without saving any settings at any time.
44
CAMERA: W - BLANCE
This feature automatically processes the viewed image to retain color
balance over temperature range. The default setting for
white balance is auto.
White Balance has following four modes.
AUTO
This mode computes the white balance value output using color
information from the entire screen. It outputs the proper value using
the color temperature radiating from a black subject based on a
range of values from 3000 to 7500K.
INDOOR
Automatic White Balance for in door. 3200K base mode.
OUTDOOR
Automatic White Balance for outdoor. 5800K base mode.
ONEPUSH
The One Push White Balance mode is a fixed white balance mode that
may be automatically readjusted only at the request of the user
(One Push Trigger).
ATW
Auto Tracing White Balance (2000 to 10000K).
MANUAL
Manual White Balance. Manual control of R and B gain, 256 stepes each.
*Note
: Auto white balance will malfunction at below condition.
- Very dark or shiny area (clear sky, sunset)
- Direct shot of fluorescent lamp or much difference brightness area
*Note
Press [ENT] or [IRIS OPEN] key to save settings and exit to previous menu or Press [Esc] or
[IRIS CLOSE] key to exit to previous menu without saving any settings at any time.
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > DOME > FOCUS/ZOOM►CAMERA > ►W-BALANCE ALARM EXPOSURE EXIT ADVANCED
<< WB SETUP >>██████████████████████████►MODE : AUTO
R GAIN : B GAIN :██████████████████████████ <Save and Exit> <Exit without Saving>
45
CAMERA: EXPOSURE
The variety of Auto Exposure functions, which allow video signal to
output the optimum image for subjects from low light condition,
to high light conditions, is available.
FULL AUTO
Auto Iris and Gain, Fixed shutter speed (NTSC : 1/60, PAL: 1/50)
Shutter Priority
Variable shutter speed, auto Iris and Gain (1/1 to 1/10000 sec)
Flicker can be eliminated by setting shutter to
1/100 for NTSC model used in countries with 50 Hz power
supply frequency.
1/120 for PAL model used in countries with 60 Hz power
supply frequency.
Iris Priority
Variable Iris (F 1.6 to Close, 18 steps), Auto Gain
and Shutter speed.
Manual
Variable Shutter, Iris and Gain
*Note
If auto iris is in the auto mode, it will remain that way until the Iris is
manually opened or closed. The dome will return to auto mode when it is panned or tilted.
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > DOME > FOCUS/ZOOM►CAMERA > W-BALANCE ALARM ►EXPOSURE EXIT ADVANCED
<< AE SETUP >>██████████████████████████►MODE : FULL AUTO
IRIS : SHUT : GAIN : BRIGHTNESS :██████████████████████████ <Save and Exit> <Exit without Saving>
46
CAMERA: ADVANCED SETUP
SHARPNESS
Settings ranges from 0 to 15. Enhances picture detail by increasing
the aperture gain of the camera and sharpening the edges in the picture.
BACKLIGHT(BLC)
Backlight compensation enhances objects in the center of the picture.
The dome uses the center of the picture to adjust the iris. If there is a
bright light source outside of this area, it will wash out to white. The
camera will adjust the iris so that the object in the sensitive area is
property exposed.
OFF (default) Backlight compensation is not activated.
ON Backlight compensation is activated.
DAY & NIGHT
Auto ICR Mode automatically switches the settings needed for
attaching or removing IR Cut filter.
LINE SYNC
INTERNAL
An internal oscillator inside camera generates a synchronizing signal as a basic oscillator.
NTSC = 28.636363MHz
PAL = 17.7344MHz
EXTERNAL
When a TTL level V-Lock pulse is input, the camera synchronizes to the input signal (V-locksynchronization).
When using camera with AC power supplier, this mode can be used.
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > DOME > FOCUS/ZOOM►CAMERA > W-BALANCE ALARM EXPOSURE EXIT ►ADVANCED
<< ADVANCED SETUP >>██████████████████████████►SHARPNESS : 04 BACKLIGHT : OFF DAY&NIGHT : ON LINE SYNC : INTERNAL -PHASE : ██████████████████████████ <Save and Exit> <Exit without Saving>
47
ALARM
IN(ALARM INPUT)
NO Normal Open.
NC Normal Close.
OUT(ALARM OUTPUT)
OFF (default) No action.
ON
PRIORITY
Alarm priority.
ACTION/NUMBER
Alarm activates various surveilance modes
with preset, tour, pattern and scan.
TIME
Alarm activation time.
To disable an alarm:
1. Use the joystick to position the cursor beside NO.xxx. Move the
joystick left or right to select a alarm number.
2. Press the [WIDE] button or turn the joystick counterclockwise to
clear an alarm.
<< ALARM SETUP >>██████████████████████████►NO.001 : █ IN : OUT : PRIORITY: ACTION : NUMBER : DWELL : ██████████████████████████ <Save and Exit> <Exit without Saving>
<<<<< Main Menu >>>>>██████████████████████████ SYSTEM > DISPLAY > DOME > CAMERA > ►ALARM EXIT
48
Camera
Wall Mount Bracket
Ceiling Mount Bracket
49
A VIEW�APole Mount Bracket
Coner Mount Bracket
50
Roof Mount Bracket
Swan Mount Bracket
51
Parapet Wall Mount Bracket
Parapet Roof Top Mount Bracket