Page 1: High-Resolution Measurements in the EUV on NSTX

High-Resolution Measurements in the EUV on NSTX

High-Resolution Measurements in the EUV on NSTX

Manfred Bitter PPPLLane Roquemore PPPLJaan Lepson UC BerkeleyMing-Feng Gu Stanford UniversitySteve Kahn Stanford University

Manfred Bitter PPPLLane Roquemore PPPLJaan Lepson UC BerkeleyMing-Feng Gu Stanford UniversitySteve Kahn Stanford University

Peter BeiersdorferLLNL

Peter BeiersdorferLLNL

DPP- Oct 25, 2005

Page 2: High-Resolution Measurements in the EUV on NSTX

Stellar plasma emission spectra

Page 3: High-Resolution Measurements in the EUV on NSTX

Stellar Flare Plasma Project:We installed a new grating spectrometer on NSTX

Page 4: High-Resolution Measurements in the EUV on NSTX

Spectral image of CCD camera from new grating spectrometer

Page 5: High-Resolution Measurements in the EUV on NSTX

Spectral lineout shows the intrinsic impurities

What about nitrogen?

Nitrogen is hardly ever seen!

Page 6: High-Resolution Measurements in the EUV on NSTX

Some shots have nitrogen

July 14, 2005Nitrogen seen in shots117087, 117113

August 17, 2005Nitrogen seen in shot117786 (strong He puff, LPI)

August 23, 2005Nitrogen seen in all RF shots

Page 7: High-Resolution Measurements in the EUV on NSTX

August 23 2005 HHFW CD shots had most diverse impurities

Page 8: High-Resolution Measurements in the EUV on NSTX

August 23 2005 HHFW CD shots had most diverse impurities

Page 9: High-Resolution Measurements in the EUV on NSTX

A detailed analysis of the "iron" data shows that some of the emission is from nickel

Page 10: High-Resolution Measurements in the EUV on NSTX

NSTX measurements agree very well with data from stellar coronae

NSTX

PrincetonTokamak

difference= opacity/

Page 11: High-Resolution Measurements in the EUV on NSTX

NBI-heated discharges produce novel line ratios – evidence for charge exchange?

Strongdecrease

Increase

Such small lineratios are notpredicted by anyknown theory!

Page 12: High-Resolution Measurements in the EUV on NSTX

Non-intrinsic impurities: Argon injection

Subsequent argoninjection runswere essentiallyinvisibleDensity sensitve

lines

Page 13: High-Resolution Measurements in the EUV on NSTX

Calibration of density-sensitive line ratios

Tokamak

Page 14: High-Resolution Measurements in the EUV on NSTX

Outlook