High pressureup to 35 MPa
Slim and neatpiping with anin-line design
0 1 2 3 4 5
5
0
10
15
20
25
30
35
40Residual Pressure Purge Speed Comparison
Time [s]
Pres
sure
[MPa
]
In-linePurge Adapter
PAD-2Our current model
<Application Example> 350 CUPLA
Ideal for eliminating residual pressure in pipingCouplings can be connected smoothly
[Test Conditions]-Fluid: Hydraulic oil-Fluid viscosity: 32×10-6 m2/s-Pressure: 35 MPa-Cubic capacity of piping: Approx. 5 L
PAD-3FM PAD-4FM
PAD-6FM PAD-8FM
Eliminates residualpressure instantlyPurge residual pressure
Tube fittings are not included. Please purchase them separately.
JustPush
Couplings and hoses are not included.Please purchase them separately.
New
Ck059
Residual Pressure Purge Adapter for Hydraulic Lines
PURGE ADAPTER
Products Complywith RoHS Directive
In-line
Specifications and designs are subject to change at any time without notice.
DISTRIBUTED BY
Head Office9-4, Nakaikegami 2-chome, Ohta-ku, Tokyo 146-8555, JapanTel : +81-3-3755-1111 Fax : +81-3-3753-8791E-mail : [email protected]/eWeb
NITTO KOHKI CO., LTD.ISO 9001ISO 14001
ISO 9001JQA-2025ISO 14001JQA-EM4057H.Q./R&D Lab
SpecificationsR 3/8
×Rc 3/8
R 1/2×
Rc 1/2R 3/4
×Rc 3/4
R 1×
Rc 140 {408} 80 {816} 150 {1530} 250 {2550}
Application
R 3/8×
Rc 3/8R 1/2
×Rc 1/2
R 3/4×
Rc 3/4R 1×
Rc 1Application
Application: Rc 1/8 (Max. Tightening Torque: 5 Nm)Drain outlet port
Torque
PAD-3FM
78.5(ø10)
PAD-4FM
122(ø12.5)
PAD-6FM
213(ø16.5)
PAD-8FM
PAD-3FM PAD-4FM PAD-6FM PAD-8FM
363(ø21.5)
Model
Min. Cross-Sectional Area
Max. Tightening Torque Nm {kgf•cm}
Seal material Mark Workingtemperature range Remarks
Nitrile rubber NBR (SG) -5˚C to +80˚C Standard materialSeal materialWorking temperature range *2
*1: The normal allowable fluid pressure under continuous use. Continuously exceeding the working pressure maycause leakage or damage. *2: The working temperature range depends upon the operating conditions.
Not suitable for vacuum application.
Min. Cross-Sectional Area (mm2)
Suitability for Vacuum
-Be sure to read the "Instruction for Purge Adapter" Safety GuideWarning
Models and Dimensions WAF : WAF stands for width across flats.
665620
Model Mass(g)
Dimensions (mm)
PAD-6FM / PAD-8FM For thread connection
Slim and neat pipingDownsizing
In-line design
Model
35.0 MPa, 357 kgf/cm2, 350 bar, 5080 PSI
Steel (Nickel plated)
Hydraulic oilApplicable fluid
Mineral greaseType of grease used
Body material
Working pressure *1
PAD-6FMPAD-8FM
-Do not use for applications other than residue pressure releasing. If the button is pressed during dynamic pressure applied, the pressure of the main system may drop and cause unexpecteddamage due to malfunction of equipment. -Do not use continuously exceeding the rated working pressure. -Do not apply any artificial impact, bend or tension. -Do not disassemble.
Caution -If the Purge Adapter is hot, use protective wear such as gloves and take special care in handling. -Do not strike the upper part of the button with a hammer or a similar tool. If the button isstiff, insert a flat head screwdriver into the groove in the Valve Holder and press the button down by leverage.
320307
Model
PAD-3FM
Mass(g)
Dimensions (mm)
PAD-3FM / PAD-4FM For thread connection
L1
72.5L2
(39)L3
21.5B
(11)øD10
P1
(51)P2
(33.5)H (WAF)
29T1
R 3/8T2
Rc 3/872.5 (39) 21.5 (11) 12.5 (51) (33.5) R 1/2 Rc 1/2
L1
86 21.5 (15.5) 16.5 (63.5) (38) Hex.46 R 3/4 Rc 3/486 21.5 (15.5) 21.5 (63.5) (38) Hex.46 R 1 Rc 1
L2 B øD P1 P2 H (WAF) T1 T2
PAD-4FM
PAD-2
PAD-3FM
Our current model
Insert an ordinary flat head screwdriver into the groove in the Valve Holder and press the button by leverage.
The groove in theValve Holder
Operate the buttonby leverage
Purge residual pressureThe tee joint is not included. Please prepare separately.
29
Can be operated with a screwdriver if the button is stiff.
P1P2
L1
HT1
D
T2
P1P2
L1H
T1
D
T2
Drain outlet port
B
L3
L2
Rc 1/8 Drain outlet port
B
L2