DATA SHEET www.brocade.com
BROCADENETIRON CES 2000SERIES
HIGH- PERFORMANCE ETHERNET SWITCHING
HIGHLIGHTS•Compact 1U IP/MPLS/VRF-enabled switch
that is purpose-built for advanced Carrier Ethernet and large data center applications
•Wire-speed, non-blocking performance inallconfigurations
•Available in 24-port and 48-port configurationsinbothHybridFiber(HF)and RJ45 versions to suit versatile access/aggregation media
•Poweredbythefield-provenBrocadeMulti-Service IronWare OS that also runs on NetIron XMR/MLX Series routers
•Advanced, scalable Carrier Ethernet services, including E-LINE, E-LAN, and E-TREE
•Comprehensive IPv4 and IPv6 routing
•Virtual Routing in non-MPLS environments via Multi-VRF
•MEF9,MEF14,andMEF21certified,with comprehensive OAM capabilities
Multi-Service Compact Ethernet Switch Series
Networkplannerstodaymustincreasinglyextend the range of their service offerings to the edge of carrier networks. However, extending intelligence and high-touch processing capabilities to the network edgerequirestheabilitytoflexiblydefineandeasilymanageservicesinanefficientmanner.Asaresult,QualityofService(QoS),resiliency,andsecurityarecriticalfactorsinthedeploymentoftheseEthernet-based services.
Whethertheyarelocatedatacentralofficeorremotesite,theavailabilityofspaceoftendeterminesthefeasibilityofdeployingnew equipment and services within a service provider, campus, or data center
environment. To meet these challenges, the Brocade® NetIron® CES 2000 Series is purpose-builttoprovideflexible,resilient,secure, and advanced Ethernet and MPLS-based services in a compact form factor.
TheNetIronCES2000Seriesisafamilyofcompact 1U, multiservice edge/aggregation switches that combine powerful capabilities withhighperformanceandavailability. The switches provide a broad set of advancedLayer2,IPv4,IPv6,andMPLScapabilities in the same device. As a result,theysupportadiversesetofapplications in metro edge, service provider, mobile backhaul, data center, and large enterprise networks.
NEBS
CERTIFIED
The Brocade One™strategyhelpssimplifynetworkinginfrastructuresthrough innovative technologies and solutions. The Brocade NetIron CES 2000 Series supports this strategybyenablingrapidservicedeploymentforleading-edge servicesandgreaterprofitability.
PROVIDING CARRIER-CLASS RESILIENCY WITH MULTI-SERVICE IRONWAREThe NetIron CES 2000 Series is built on the same Brocade Multi-Service IronWare® operatingsystemthatpowersmission-critical NetIron XMR and Brocade MLX Seriesrouters,simplifyingintegrationwithexistingnetworks.Keycapabilitiesincludeanindustry-standardinterface,supportfor robust routing protocols, MPLS VPNs, advancedLayer2protocols,abroadrangeofOAMprotocols,advancedsecurity,andsimplifiedmanagement.
In addition, IronWare supports Provider Bridge(PB)andProviderBackboneBridge(PBB)functionalities.ThisrichsetoffunctionalitymakesiteasiertointegratetheNetIron CES 2000 Series with existing OSS systemsthatarecertifiedtointeroperatewith Multi-Service IronWare-based products.
ENABLING TRUE CARRIER-GRADE ETHERNET SERVICESCarrier Ethernet is a ubiquitous offering definedbyfiveattributes—standardizedservices,scalability,servicemanagement,reliability,andQoS—allofwhicharesupportedbytheNetIronCES2000Series.
A Carrier Ethernet service can be delivered overanytransporttechnologyaslongasitsatisfiesthestandardsandattributesassociated with the service. Examples of possibleunderlyingtransportmechanismsinclude native Ethernet using 802.1Q VLANs,MPLS-basedLayer2VPNs,IEEE802.1ad PBs, and IEEE 802.1ah PBBs.
Standardized ServicesBecause the NetIron CES 2000 Series is certifiedforMEF9,MEF14,andMEF21,providers can offer E-LINE, E-LAN, and E-TREEservices—thestandardizedservicenames for point-to-point, multipoint, and rooted multipoint services. These services can be offered using 802.1Q VLANs, PBs, PBBs,orMPLSLayer2VPNs.
ScalabilityThe NetIron CES 2000 Series supports up to128,000MACaddressespersystem.Support for 100/1000 Mbps SFP ports or10/100/1000MbpsRJ45ports(withwire-speedperformanceevenatfullload)helpsensureavailablecapacityonuser-facing ports to accommodate provider customers that want to upgrade to a higher-bandwidth service. In addition, the use of LinkAggregationGroups(LAGs)enablesthe aggregation of multiple links to provide even higher-bandwidth services at the User NetworkInterface(UNI).
TosupporthighlyscalableCarrierEthernetservices, Brocade has developed an innovative framework called Ethernet ServiceInstance(ESI).UsingtheESIframework,providerscanflexiblydefineand assign VLANs to service instances withinthenetwork—enablingthemtorapidlyinstantiateandeasilymanageE-LINE,E-LAN, and E-TREE services.
•Large-scale Carrier Ethernet build-outs attheglobal,national,andmetrolevels—combined with Brocade MLX® and NetIron XMR Series routers
•High-densityaggregationofaccessdevices such as DSLAMs, PON ONTs, or CMTSsystemsatthenetworkedge
•Edge aggregation switching and routing applications in metro networks
•MPLS access and aggregation
•MultiplesecurityzonesandsimplifiedVPNs for enterprise and campus networks using Multi-VRF
•Mobile backhaul over Carrier Ethernet infrastructure
•FiberToTheHome(FTTH)and FiberToTheBuilding(FTTB) applications with stringent Service LevelAgreements(SLAs)
•Aggregation in ISP networks
•High-performance data center top-of-rack server access with high-touch processing and deep buffering
Key Applications
Service ManagementSpecificationssuchasIEEE802.1ag-2007(ConnectivityFaultManagement)andMEF17(ServiceOAMFrameworkandSpecifications)enablefast,proactiveidentificationandisolationoffaultsinthenetwork or service, helping to increase serviceuptimeandtheabilitytomeetSLAs.
The NetIron CES 2000 Series supports all the capabilities in IEEE 802.1ag, including ConnectivityCheckMessages,LoopbackMessage/Response, and LinkTrace Message/Response.ItallowsflexibleassociationanddefinitionofbothMaintenanceEndPoints(MEPs)andMaintenanceIntermediatePoints(MIPs)withinanetwork.Fault management functions of MEF 17 Service OAM are also supported. Together, these tools provide the capabilities to monitor, diagnose,andcentrallymanagethenetwork.
ReliabilityToprovidehigherreliabilityinCarrierEthernetservices, the NetIron CES 2000 Series supportsMetroRingProtocol(MRP/MRP-II),
theringresiliencyprotocolofchoiceonmanymetronetworksworldwide.StandardLayer2protocols such as MSTP, RSTP, and STP are also supported. The Brocade MRP/MRP-II implementationenablesthedeliveryofCarrier Ethernet services over ring-based topologies, including overlapping rings that helpoptimizetheuseoffiberinmetroringsandproviderecoveryfromnode/linkfailuresin milliseconds. Brocade MRP/MRP-II can also be used within PB/PBB networks.
Hard QoSThe NetIron CES 2000 Series supports up to eight queues per port, each with a distinct prioritylevel.ProviderscanapplyadvancedQoScapabilities(suchastheuseof2-rate,3-colortrafficpolicers,egressshaping,andpriorityremarking)toofferadeterministic“hardQoS”capabilitytocustomersoftheservice. In addition, the NetIron CES 2000 SeriescanbeconfiguredwithingressandegressbandwidthprofilesperUNIthatcomplywiththerigidtrafficmanagementspecificationsofMEF10/MEF14.
LEGEND: PB: Provider Bridge (802, 1AD). PBB: Provider Backbone Bridge (802, 1AH). PBN: Provider Bridged Network. PBBN: Provider Backbone Bridged Network.
MPLS
MOBILE BACKHAUL
PBN
PBN PBN
PBBN
PBBNENTERPRISE ACCESS
ENTERPRISE ACCESS
PON AGGREGATION
RESIDENTIALTRIPLE PLAY
DSLAM AGGREGATION
PBBN
NetIron XMR/MLX
NetIron XMR/MLX
NetIron XMR/MLX
Provider Edge
Provider Edge
Provider Edge
NetIron XMR/MLX
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
PBN
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
DSLAMDSLAM
DSLAMFastIron
ESFastIron
ES
Figure 1. A possible application of using PBB technologyonNetIronCES2000Seriesswitches in a large Carrier Ethernet network.
USING PBB/VPLS TO SCALE CARRIER ETHERNET SERVICESMostnetworkcorestodayarebasedonMPLS.ByusingVPLS,providerscaneasilyleverageanexistingMPLSnetworkto offer Carrier Ethernet services. In a VPLS network, participating Provider Edge(PE)devicesestablishafullmeshofpseudowires among all nodes in a VPLS instance.ToensurescalabilityoftheVPLSservice,providerscanutilizehierarchicalVPLS to limit the number of PE devices that participate in the full mesh.
Inaddition,theycanusePBBtechnologytoimplementhierarchicalVPLSbycross-connectingVPLSatthePErouter(thehubdevice)toPBBspokesatthenetworkedge.Implementing hierarchical VPLS with PBB spokesprovidesanextremelysimplewaytoscale the VPLS service while reducing signaling overhead within the MPLS network.
Moreimportantly,itsignificantlyincreasesthescalabilityoftheoverallsolution,becausetheMPLSPErouteriscompletelyinsulatedfromcustomerMACaddresses—itmaps frames based on the backbone MAC header to a VPLS instance. Figure 1 shows anexampleofusingPBBtechnologyon
Figure 2. The NetIron CES 2000 Series supports Multi-VRF tohelpincreasebothsecurityandROI.
Data Center Access
Data Center Aggregation/Core
Multi-VRF Routing
Data Center Core
BrocadeMLX
BrocadeMLX
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
NetIron CES 2000
the NetIron CES 2000 Series with VPLS on the NetIron XMR/MLX Series to achieve unparalleledscalabilityinservicedelivery.
HIGH-PERFORMANCE TOP-OF-RACK SWITCH FOR DATA CENTERSIn the data center, cost reduction, virtualization,security,andconsolidationcontinue to be the top priorities. Growth in datatrafficandrisingapplicationdemandsrequire higher levels of performance and theabilitytoscalewithmorestorageandnetwork bandwidth.
The NetIron CES 2000 Series is designed to meet the challenges of campus and largedatacenternetworksbyprovidingabroad set of capabilities, including wire-speed performance, deep packet buffers, andlowlatencyinacompact1Uformfactor. Comprehensive support for IPv4 routing protocols, when complemented with VRRP and VRRP-E, is well suited for these environments. In addition, the NetIron CES 2000 series supports advanced services suchasMPLS(VLL,VPLS),QoS,andLayer3Virtualization(VRF)—makingitanidealtop-of-rack switch in high-end data centers or an edge router in campus networks.
Figure 2 shows an example of using Multi-VRF on the NetIron CES 2000 Series. Multi-VRF enables a single device to host multiple routingtablesandallowsapplicationtrafficseparationatLayer3forSLAassurance,regulatorycompliance,andsecurity.AnadditionalbenefitofMulti-VRFisreducedmaintenance and capital costs as well as betterbandwidthutilizationtoincreaseROI.
MULTICAST SUPPORTMulticasttransportisakeyenablerofnext-generation services such as IPTV as wellastheuseofvideo,financial,andotherone-to-manyapplications.Tomeetthis challenge, the NetIron CES 2000 Series provides comprehensive support for multicast switching and routing through avarietyofprotocols,includingPIM-SM,PIM-DM, PIM-SSM, IGMP v2/v3, and other platform-independent capabilities. Egress interface-basedreplicationoptimizesswitch performance and buffer usage withinthesystemtohelpmaximizenetworkperformanceformulticasttraffic.
ROUTING CAPABILITIESThe NetIron CES 2000 Series offers routing capabilitiesthatarecommonlyrequiredinedge aggregation and other applications within a provider’s domain. These capabilities include advanced hardware-based routing technology,whichensuressecureandrobust wire-speed routing performance.
The NetIron CES 2000 Series supports IPv4 andIPv6unicastprotocols—RIP/RIPng,OSPF/OSPFv3, IS-IS/IS-IS for IPv6, and BGP/BGP-MP for IPv6. To increase overall
serviceavailability,italsosupportsGracefulRestart helper mode for both OSPF and BGP, enabling hitless management failover and hitless OS upgrades on adjacent modular routers with these functions.
SECURITY CAPABILITIESMulti-ServiceIronWarecontainssecuritycapabilities that are available on the NetIron CES 2000 Series. These capabilities support inbound and outbound ACLs, ACL logging,advancedLayer2controls,limitsfor broadcast/unknown unicast/multicast, Multi-VRF,Layer2VPNs,andmore.
Receive ACLs assist in placing controls on unwantedtraffictargetedtowardthecontrolplane. Through tools such as ACL-based trafficpolicers,ACL-basedsFlow,andACL-basedmirroring,malicioustrafficcanbeeasilyidentifiedandpreventivemeasurestaken in the network. In addition, Multi-VRF can help segment the network into different zonesforsecurityandisolation.
SOFTWARE-DEFINED NETWORKING Software-DefinedNetworking(SDN)isapowerful new network paradigm designed for the world’s most demanding networking environments. The NetIron CES 2000 Series enablesSDNbysupportingtheOpenFlowprotocol, which allows communication between an OpenFlow controller and an OpenFlow-enabled switch. Using this approach,organizationscancontrol theirnetworksprogrammatically,transforming the network into a platform for innovation through new network applications and services.
BROCADE GLOBAL SERVICES Brocade Global Services has the expertise tohelporganizationsbuildscalable,efficientcloudinfrastructures.Leveraging15yearsofexpertiseinstorage,networking,andvirtualization,BrocadeGlobalServicesdelivers world-class professional services, technical support, network monitoring services, and education, enabling organizationstomaximizetheirBrocadeinvestments,acceleratenewtechnologydeployments,andoptimizetheperformanceof networking infrastructures.
CLOUD-OPTIMIZED NETWORK ACQUISITION Brocadehelpsorganizationseasilyaddresstheirinformationtechnologyrequirementsbyofferingflexiblenetworkacquisitionandsupportalternativestomeettheirfinancialneeds.Organizationscanselectfrompurchase, lease, and Brocade Network Subscription options to align network acquisition with their unique capital requirementsandriskprofiles.
MAXIMIZING INVESTMENTSTohelpoptimizetechnologyinvestments,Brocade and its partners offer complete solutions that include professional services, technical support, and education. For more information, contact a Brocade sales partner or visit www.brocade.com.
KEY FEATURES
Advanced Carrier-Grade Ethernet services•Up to 128,000 MAC addresses
•4000 VLANs/S-VLANs/B-VLANs
•AbilitytoreuseVLAN-IDoneachportusingthe BrocadeEthernetServiceInstance(ESI)framework
•MPLSservices:IPoverMPLS,VirtualLeasedLine(VLL), andVirtualPrivateLANService(VPLS)
• IEEE 802.1ad Provider Bridges
• IEEE 802.1ah Provider Backbone Bridges
•IEEE802.1agConnectivityFaultManagement
•ComprehensivesetofLayer2controlprotocols: Brocade MRP/MRP-II, VSRP, RSTP, and MSTP
•MEF9,MEF14,andMEF21certification
•E-LINE(EPLandEVPL),E-LAN,andE-TREEsupport
•Protocol tunneling of customer BPDUs
• ITU Y.1731 OAM functions and mechanisms for Ethernet-based networks
Comprehensive IPv4/IPv6 unicast routing support based on the Brocade Multi-Service IronWare OS•High-performance, robust routing using Forwarding InformationBase(FIB)programminginhardware
•RIP/RIPng, OSPF/OSPFv3, IS-IS/IS-IS for IPv6, and BGP-4/BGP-MP for IPv6
•Secure Multi-VRF routing to support Virtual Routing applications over non-MPLS backbones
•Support for VRRP and VRRP-E
•8-pathEqualCostMultipath(ECMP)
•Up to 32,000 IPv4 unicast routes in FIB
•Up to 8000 IPv6 unicast routes in FIB
•Connecting IPv6 islands over IPv4 MPLS using IPv6 Provider Edgerouters(6PE)
Support for trunks (link aggregation groups) using either IEEE 802.3ad LACP or static trunks •Up to 12 links per trunk
•Support for single-link trunks
Rich multicast support •Supported IPv4 multicast protocols, including PIM-DM,
PIM-SM, and PIM-SSM
• IGMP v2/v3 routing and snooping support
• IGMP static groups support
•Multicast boundaries to facilitate admission control
•PIM and MLD snooping for IPv6
•Up to 4000 multicast groups in hardware
•MulticasttrafficdistributionoverLAGs
•Efficientegressinterface-basedreplicationtomaximizeperformance and conserve buffers
Deep egress buffering for transient bursts in traffic •64MBto192MBofbuffering,basedonconfiguration
Advanced QoS •Inboundandoutboundtwo-ratethree-colortrafficpolicers
with accounting
•Eightqueuesperport,eachwithadistinctprioritylevel
•Multiple queue servicing disciplines: StrictPriority,WeightedFairQueuing,andhybrid
•Advanced remarking capabilities based on port, VLAN, PCP,DSCP,orIPv4flow
•Egressportandpriority-basedshaping
Comprehensive hardware-based security and policies •Hardware-basedLayer3andLayer2ACLs (bothinboundandoutbound)withlogging
•AbilitytobindmultipleACLstothesameport
•Hardware-based receive ACLs
•Hardware-basedPolicy-BasedRouting(PBR)
Additional security capabilities •Port-based network access control using 802.1x or MACportsecurity
•Root guard and BPDU guard
•Broadcast, multicast, and unknown unicast rate limits
•ARP Inspection for static entries
Advanced monitoring capabilities •Port-andACL-basedmirroringthatenablestrafficmirroringbasedonincomingport,VLAN-ID,orIPv4/TCP/UDPflow
•Hardware-basedsFlowsamplingthatallowsextensiveLayer2-7trafficmonitoringforIPv4andCarrierEthernetservices
•ACL-based sFlow support
Interface capabilities •Jumboframesupportupto9216bytes
•Optical monitoring of SFP and XFP optics for fast detection offiberfaults
•UDLD and LFS/RFN support
Intuitive, comprehensive status indication via LEDs •Per-port UP/DOWN/ACTIVITY indicators
•FANtraystatus
•Powersupplystatus
Redundancy •Redundant, hot-swappable AC/DC power supplies at the rear
•Removablefantraywithfanredundancy
Software-Defined Networking (SDN)•Support for OpenFlow v1.0
Features NetIron CES 2024C
NetIron CES 2024F
NetIron CES 2048C
NetIron CES 2048F
NetIron CES 2048CX
NetIron CES 2048FX
PortDensity 24 10/100/1000 RJ45 ports with optional slot for 2×10 GbE XFP uplinks
24100/1000HybridFiber SFP ports with optional slot for 2×10 GbE XFP uplinks
48 10/100/1000 RJ45 ports
48 100/1000 SFP ports
48 10/100/1000 RJ45 ports with 2×10 GbE XFP uplinks
48100/1000HybridFiber SFP ports with 2×10 GbE XFP uplinks
10 GbE Uplinks Yes(optionalslotfor 2×10 GbE XFP uplinks)
Yes(optionalslotfor 2×10 GbE XFP uplinks)
No No Yes(builtin) Yes(builtin)
Combination Ports Yes(4100/1000SFPports)
Yes(410/100/1000RJ45ports)
Yes(4100/1000SFPports)
No No No
Forwarding Performance
48 Gbps 88 Gbps (with2×10GbE moduleinstalled)
48 Gbps 88 Gbps (with2×10GbE moduleinstalled)
96 Gbps 96 Gbps 136 Gbps 136 Gbps
Packet Forwarding Performance
36 Mpps 65 Mpps (with2×10GbE moduleinstalled)
36 Mpps 65 Mpps (with2×10GbE moduleinstalled)
71 Mpps 71 Mpps 101 Mpps 101 Mpps
Buffering 64 MB 128 MB (with2×10GbEuplinks)
64 MB 128 MB (with2×10GbEuplinks)
128 MB 128 MB 192 MB 192 MB
PowerSupplyOptions
Internal AC or DC Internal AC or DC Internal AC or DC Internal AC or DC Internal AC or DC Internal AC or DC
PowerSupplyRedundancy
1+1 1+1 1+1 1+1 1+1 1+1
FanRedundancy M+N M+N M+N M+N M+N M+N
Airflow Front to back Front to back Front to back Front to back Front to back Front to back
BROCADE NETIRON CES 2000 SERIES BY THE NUMBERS
SOFTWARE OPTIONS
Premium License ContentBASE FundamentalLayer2and3functions:
•AllClassicLayer2capabilities
•BaseLayer3(RIPandstaticroutes)
•QoSandACLs
•ManagementviaSNMP/CLI
•Bundledwithbasehardware
•ConnectivityFaultManagement(IEEE802.1ag)andServiceOAM
ME_PREM(MetroEdgePremiumLicense) All functions in BASE plus:
•ProviderBridges(IEEE802.1ad)
•ProviderBackboneBridges(IEEE802.1ah)
•In-bandmanagementforPB/PBBnetwork
•IPv4routing:OSPFandISIS
•IPv6routing:RIPng,OSPFv3,andIS-ISforIPv6
•EthernetServiceInstance(ESI)framework
•Multi-VRF
•MPLS(IPoverMPLS,VPLS,VLL)
•802.3ahLinkOAM
L3_PREM(Layer3PremiumLicense) All functions in BASE plus:
•IPv4routing:OSPF,ISIS,andBGP
•IPv6routing:RIPng,OSPFv3,IS-ISforIPv6,andBGP-MPforIPv6
•Multi-VRF
Note: To optimize deployment, software functionality is available in different licensed packages.
DimensionsNetIron CES 2024C 17.4in.W×1.7in.H×17.6in.D(44.3cm×4.4cm×44.8cm)
NetIron CES 2024C with 2×10 GbE uplink installed 17.4in.W×1.7in.H×17.6in.D(44.3cm×4.4cm×44.8cm)
NetIron CES 2024F 17.4in.W×1.7in.H×17.6in.D(44.3cm×4.4cm×44.8cm)
NetIron CES 2024F with 2×10 GbE uplink installed 17.4in.W×1.7in.H×17.6in.D(44.3cm×4.4cm×44.8cm)
NetIron CES 2048C 17.4in.W×1.7in.H×17.3in.D(44.3cm×4.4cm×43.9cm)
NetIron CES 2048CX 17.4in.W×1.7in.H×17.3in.D(44.3cm×4.4cm×43.9cm)
NetIron CES 2048F 17.4in.W×1.7in.H×17.3in.D(44.3cm×4.4cm×43.9cm)
NetIron CES 2048FX 17.4in.W×1.7in.H×17.3in.D(44.3cm×4.4cm×43.9cm)
BROCADE NETIRON CES 2000 SERIES PHYSICAL SPECIFICATIONS
Configuration Maximum AC Power Consumption (Watts) (100 to 240V AC)
Maximum DC Power Consumption (Watts)
Maximum Thermal Output (BTU/hour)
NetIron CES 2024C 120 120 410
NetIron CES 2024C with 2×10 GbE uplink installed 170 170 580
NetIron CES 2024F 145 145 495
NetIron CES 2024F with 2×10 GbE uplink installed 195 195 666
NetIron CES 2048C 205 205 700
NetIron CES 2048CX 255 255 870
NetIron CES 2048F 245 245 836
NetIron CES 2048FX 295 295 1007
BROCADE NETIRON CES 2000 SERIES POWER SPECIFICATIONS
IEEE Compliance• IEEE 802.3 10Base-T• IEEE 802.3u 100Base-TX, 100Base-FX, 100Base-LX• IEEE802.3z1000Base-SX/LX• IEEE 802.3ab 1000Base-T• 802.3CSMA/CDAccessMethodandPhysicalLayerSpecifications• 802.3ae 10 Gigabit Ethernet• 802.3x Flow Control• 802.3ad Link Aggregation• 802.1Q Virtual Bridged LANs• 802.1D MAC Bridges• 802.1w Rapid STP• 802.1s Multiple Spanning Trees• 802.1x Port-based Network Access Control• 802.1ad Provider Bridges• 802.1ah Provider Backbone Bridges• 802.1agConnectivityFaultManagement(CFM)• 802.1abLinkLayerDiscoveryProtocol• 802.1ah Provider Backbone Bridging
ITU Compliance• ITU Y.1731 OAM functions and mechanisms for Ethernet-based networks
MEF Specifications•MEF 2 Requirements and Framework for Ethernet Service Protection•MEF 4 Metro Ethernet Network Architecture Framework
Part 1: Generic Framework• MEF6.1MetroEthernetServicesDefinitionsPhase2•MEF 9 Abstract Test Suite for Ethernet Services at the UNI•MEF 10.1 Ethernet Services Attributes Phase 2• MEF11UserNetworkInterface(UNI)RequirementsandFramework•MEF 12 Metro Ethernet Network Architecture Framework Part2:EthernetServicesLayer
• MEF13UserNetworkInterface(UNI)Type1ImplementationAgreement• MEF14AbstractTestSuiteforTrafficManagementPhase1•MEF 15 Requirements for Management of Metro Ethernet Phase 1
Network Elements• MEF17ServiceOAMFrameworkandRequirements(partial)• MEF19AbstractTestSuiteforUNIType1• MEF21AbstractTestSuiteforUNIType2Part1LinkOAM
RFC ComplianceBGPv4 • RFC 4271 BGPv4
• RFC 1745 OSPF Interactions• RFC 1997 Communities and Attributes• RFC 2439 Route Flap Dampening• RFC2796RouteReflection• RFC 1965 BGP4 Confederations• RFC2842CapabilityAdvertisement• RFC2918RouteRefreshCapability• RFC 1269 Managed Objects for BGP• RFC 2385 BGP Session Protection
via TCP MD5• RFC3682GeneralizedTTLSecurity
Mechanism, for eBGP Session Protection• RFC 4273 BGP-4 MIB• RFC 4893 BGP Support for Four-octet AS
Number Space• RFC 5396 Textual Representation of AutonomousSystem(AS)Numbers
• RFC 4724 Graceful Restart Mechanism for BGP(helpermode)
OSPF • RFC 2328 OSPF v2• RFC 3101 OSPF NSSA• RFC 1745 OSPF Interactions• RFC1765OSPFDatabaseOverflow• RFC 1850 OSPF v2 MIB
OSPF(continued) • RFC 2370 OSPF Opaque LSA Option• RFC 3630 TE Extensions to OSPF v2• RFC 3623 Graceful OSPF Restart (helpermode)
MPLS • RFC 3031 MPLS Architecture• RFC 3032 MPLS Label Stack Encoding• RFC3036LDPSpecification• RFC2205RSVPv1FunctionalSpecification• RFC 2209 RSVP v1 Message Processing
Rules• RFC 3209 RSVP-TE• RFC 3270 MPLS Support of
Differentiated Services• RFC 3812 MPLS MIB• RFC 4090 Fast Reroute Extensions to
RSVP-TE for LSP Tunnels; partial support• RFC5443LDPIGPSynchronization• RFC5712MPLSTrafficEngineering
Soft PreemptionLayer2VPNandPWE3 • RFC4664FrameworkforLayer2Virtual
Private Networks• RFC 4664 Service Requirements for Layer2Provider-ProvisionedVirtual Private Networks
• RFC 4762 VPLS using LDP Signaling• draft-ietf-pwe3 PWE3 Architecture• RFC 4447 Pseudowire Setup and
Maintenance using LDP• RFC 4448 Encapsulation Methods for
Transport of Ethernet over MPLS Networks• RFC5542DefinitionsforTextual
Conventions for Pseudo-Wires Management• RFC5601Pseudowire(PW)Management
Information BaseIS-IS • RFC 1195 Routing in TCP/IP and
Dual Environments• RFC 1142 OSI IS-IS Intra-domain
Routing Protocol• RFC2763DynamicHostNameExchange• RFC2966Domain-widePrefixDistribution• RFC5120IS-ISMulti-TopologySupport
RIP •RFC1058RIPv1•RFC2453RIPv2•RFC1812RIPRequirements
IPv4 multicast • RFC 1122 Host Extensions• RFC 1112 IGMP• RFC 2236 IGMP v2• RFC 3376 IGMP v3• RFC 3973 PIM-DM• RFC 2362 PIM-SM• RFC4610AnycastRPusingPIM
IPv6 core • RFC2460IPv6Specification• RFC2461IPv6NeighborDiscovery• RFC2462IPv6StatelessAddress—Auto-Configuration
• RFC 4443 ICMPv6• RFC 4291 IPv6 Addressing Architecture• RFC3587IPv6GlobalUnicast—Address
Format• RFC 2375 IPv6 Multicast Address
Assignments• RFC 2464 Transmission of IPv6 over
Ethernet Networks• RFC 2711 IPv6 Router Alert Option• RFC3315DynamicHostConfigurationProtocol(DHCP)forIPv6
IPv6 routing • RFC 2080 RIPng for IPv6• RFC 2740 OSPFv3 for IPv6• draft-ietf-isis-ipv6 Routing IPv6 with IS-IS• RFC 2545 Use of BGP-MP for IPv6
BROCADE NETIRON CES 2000 SERIES SPECIFICATIONS
IPv6 transitioning • RFC 4798 Connecting IPv6 Islands over IPv4 MPLS Using IPv6 Provider Edge Routers(6PE)
General protocols • RFC 791 IP• RFC 792 ICMP• RFC 793 TCP• RFC 1350 TFTP• RFC 826 ARP• RFC 768 UDP• RFC 894 IP over Ethernet• RFC 903 RARP• RFC 906 TFTP Bootstrap• RFC1027ProxyARP• RFC 951 BootP• RFC 1122 Host Extensions
for IP Multicasting• RFC 1256 IRDP• RFC 1519 CIDR • RFC 1542 BootP Extensions• RFC 1812 Requirements for IPv4 Routers• RFC 1541 and 1542 DHCP• RFC 2131 BootP/DHCP Helper• RFC 3768 VRRP• RFC 854 TELNET• RFC1591DNS(client)
QoS • RFC 2475 An Architecture for Differentiated Services
• RFC 3246 An Expedited Forwarding PHB• RFC 2597 Assured Forwarding PHB Group• RFC 2698 A Two Rate Three Color Marker
Other • RFC 1354 IP Forwarding MIB• RFC 2665 Ethernet Interface MIB• RFC 1757 RMON Groups 1,2,3,9• RFC 2068 HTTP• RFC 4330 SNTP• RFC 2865 RADIUS• RFC 3176 sFlow• RFC 2863 Interfaces Group MIB• Draft-ietf-tcpm-tcpsecureTCPSecurity• draft-ietf-bfd-base Bidirectional Forwarding Detection(BFD)
• RFC 2784 Generic Routing Encapsulation (GRE)
• RFC4741NETCONF(Partial)• RFC 4087 IP Tunnel MIB
Network Management• BrocadeNetworkAdvisorWeb-basedGraphicalUserInterface(GUI)• Integratedindustry-standardCommandLineInterface(CLI)• sFlow(RFC3176)• Telnet• SNMP v1, v2c, v3• SNMP MIB II• RMON• NETCONF
Element Security Options• AAA• RADIUS• SecureShell(SSHv2)• SecureCopy(SCPv2)• HTTPs• TACACS/TACACS+• Username/Password(ChallengeandResponse)• Bi-levelAccessMode(StandardandEXECLevel)• Protection against Denial of Service attacks, such as TCP SYN
or Smurf Attacks
Environmental• Operatingtemperature:0°Cto40°C(32°Fto104°F)• Relativehumidity:5%to90%,at40°C(104°F),non-condensing• Operatingaltitude:10,000ft(3048m)• Storagetemperature:–25°Cto70°C(–13°Fto158°F)• Storagehumidity:95%maximumrelativehumidity,non-condensing• Storagealtitude:15,000ft(4500m)maximum
Safety Agency Approvals• CAN/CSA-C22.2 No. 60950-1-3• UL 60950-1• IEC 60950-1• EN60950-1SafetyofInformationTechnologyEquipment• EN60825-1SafetyofLaserProducts—Part1:EquipmentClassification,
Requirements and User’s Guide• EN60825-2SafetyofLaserProducts—Part2:SafetyofOpticalFibreCommunicationSystems
Electromagnetic Emission• ICES-003 Electromagnetic Emission• FCC Class A• EN 55022/CISPR-22 Class A/VCCI Class A• AS/NZS 55022• EN 61000-3-2 Power Line Harmonics• EN 61000-3-3 Voltage Fluctuation & Flicker• EN61000-6-3EmissionStandard(Supersedes:EN50081-1)
Immunity• EN61000-6-1GenericImmunityandSusceptibility;thissupersedesEN50082-1• EN55024ImmunityCharacteristics.Thissupersedes: —EN61000-4-2ESD —EN61000-4-3Radiated,radiofrequency,electromagneticfield —EN61000-4-4Electricalfasttransient —EN61000-4-5Surge —EN61000-4-6Conducteddisturbancesinducedbyradio-frequencyfields —EN61000-4-8Powerfrequencymagneticfield —EN61000-4-11Voltagedipsandsags
Telco NEBS/ETSI• TelcordiaGR-63-CORENEBSRequirements:PhysicalProtection• TelcordiaGR-1089-COREEMCandElectricalSafety• Telcordia SR-3580 Level 3• ETSIETS300-019PhysicalProtection: —Part1-1,Class1.1,PartlyTemperatureControlledStorageLocations —Part1-2,Class2.3,PublicTransportation —Part1-3,Class3.1,TemperatureControlledLocations(Operational)•ETSIETS300-386EMI/EMC
Power and Grounding• ETS 300 132-1 Equipment Requirements for AC Powered Equipment
Derived from DC Sources• ETS 300 132-2 Equipment Requirements for DC Powered Equipment• ETS300253FacilityRequirements
Physical Design and MountingRack mount 19-inch rack mount supporting racks
compliant with:• ANSI/EIA-310-D• ETS 300 119• GR-63-CORE Seismic Zone 4
Tabletop
Environmental Regulatory Compliance• EU 2002/95/EC RoHS• EU 2002/96/EC WEEE
BROCADE NETIRON CES 2000 SERIES SPECIFICATIONS (CONTINUED)
Part Number DescriptionNI-CES-2024C-AC NetIronCES2024C,24×1GbEcopper(RJ45)configurationwithfour
combination 100/1000 SFP ports, one optional slot, and one 500-watt ACpowersupply
NI-CES-2024C-DC NetIronCES2024C,24×1GbEcopper(RJ45)configurationwith four combination 100/1000 SFP ports, one optional slot, and one500-wattDCpowersupply
NI-CES-2024F-AC NetIronCES2024F,24×1GbEHybridFiber(HF)SFPconfigurationwith four combination 10/100/1000 RJ45 ports, one optional slot, and one500-wattACpowersupply
NI-CES-2024F-DC NetIronCES2024F,24×1GbEHybridFiber(HF)SFPconfigurationwith four combination 10/100/1000 RJ45 ports, one optional slot, and one 500-wattDCpowersupply
NI-CES-2024-2x10G NetIron CES 2000 Series 2×10 GbE XFP uplink for 24-port NetIron CES 2000Seriesswitches(bothACandDCmodels)
NI-CES-2048C-AC NetIronCES2048C,48×1GbEcopper(RJ45)configurationwithfourcombination100/1000SFPportsandone500-wattACpowersupply
NI-CES-2048C-DC NetIronCES2048C,48×1GbEcopper(RJ45)configurationwithfourcombination100/1000SFPportsandone500-wattDCpowersupply
NI-CES-2048F-AC NetIronCES2048F,48×1GbEHybridFiber(HF)SFPconfigurationwith one500-wattACpowersupply
NI-CES-2048F-DC NetIronCES2048F,48×1GbEHybridFiber(HF)SFPconfigurationwith one500-wattDCpowersupply
NI-CES-2048CX-AC NetIronCES2048CX,48×1GbEcopper(RJ45)with2×10GbEXFPuplinksconfigurationandone500-wattACpowersupply
NI-CES-2048CX-DC NetIronCES2048CX,48×1GbEcopper(RJ45)with2×10GbEXFPuplinksconfigurationandone500-wattDCpowersupply
NI-CES-2048FX-AC NetIronCES2048FX,48×1GbEHybridFiber(HF)withone500-wattACpowersupplyand2×10GbEXFPuplinksconfiguration
NI-CES-2048FX-DC NetIronCES2048FX,48×1GbEHybridFiber(HF)withone500-wattDCpowersupplyand2×10GbEXFPuplinksconfiguration
NI-CES-2024-MEU Metro Edge Premium upgrade for NetIron CES 2000 Series 24-port models
NI-CES-2024-L3U Layer3PremiumupgradeforNetIronCES2000Series24-portmodels
NI-CES-2048-MEU Metro Edge Premium upgrade for NetIron CES 2000 Series 48-port models
NI-CES-2048-L3U Layer3PremiumupgradeforNetIronCES2000Series48-portmodels
ORDERING INFORMATION
DATA SHEET www.brocade.com
©2012BrocadeCommunicationsSystems,Inc.AllRightsReserved.04/12GA-DS-1277-05
Brocade,BrocadeAssurance,theB-wingsymbol,DCX,FabricOS,MLX,SANHealth,VCS,andVDXareregisteredtrademarks,andAnyIO,BrocadeOne,CloudPlex,EffortlessNetworking,ICX,NETHealth,OpenScript,andTheEffortlessNetworkaretrademarksofBrocadeCommunicationsSystems,Inc.,intheUnitedStatesand/orinothercountries.Otherbrands,products,orservicenamesmentionedmaybetrademarksoftheirrespectiveowners.
Notice:Thisdocumentisforinformationalpurposesonlyanddoesnotsetforthanywarranty,expressedorimplied,concerninganyequipment,equipmentfeature,orserviceofferedortobeofferedbyBrocade.Brocadereservestherighttomakechangestothisdocumentatanytime,withoutnotice,andassumesnoresponsibilityforitsuse.Thisinformationaldocumentdescribesfeaturesthatmaynotbecurrentlyavailable.ContactaBrocadesalesofficeforinformationonfeatureandproductavailability.Exportoftechnicaldatacontainedinthisdocumentmayrequireanexport license from the United States government.
Corporate Headquarters San Jose, CA USAT: [email protected]
European Headquarters Geneva,SwitzerlandT: +41-22-799-56-40 [email protected]
Asia Pacific Headquarters SingaporeT: +65-6538-4700 [email protected]