We offer a full line of FE Petro Products
Citation preview
HIGH CAPACITY TURBINE PUMPS HCP
Available with either 3 or 5horsepower, 50 or 60 hertzpower, the FE Petro HighCapacity Pump delivers efficient,reliable, and quiet performancewhen high volumes or highspeed deliveries of gasoline ordiesel fuel are required. Optionalsyphon assembly is available somore than one tank can be usedfor each grade of product.
High PerformanceFE Petro’s two-stage
centrifugal pump design iscoupled with a dependableFranklin Electric motorto provide higherheads, faster fueldelivery andlower costoperation.M o t o r sare allt h r e ephase f o r s m o o t htrouble-freeoperation, andare available in various voltages.
Units come standard with 6”diameter riser pipe to mount thepump to the tank.
Ease of MaintenanceIf service is required, all
FE Petro products are designedto put the operator back inbusiness fast. Maintenance onthe pump motor assembly, canbe performed without having anelectrician on site, because nowires are broken. Large diameterpins and sockets provideautomatic open circuiting anddisconnecting of the wiringwhen the extractable portion ofthe pump is removed. There isno difficult cam lock which hasto be turned. Easily removedbolts provide the means toextract the unit. Properly spacedlifting eyes facilitate the removal
of the unit without disturbingthe discharge piping. Thesyphon (if connected) isnot disturbed whenremoving thee x t r a c t a b l eassembly, andthe pumpm o t o r
assemblyis easily
removed fromthe discharge
head by removingfour bolts and using
standard pusher bolts.Replacement pump motor
assemblies are available forcomparably sized existingTokheim and Red Jacket pumps.
ReliabilityQuality engineering and
simplicity of design work hand inhand to insure years of reliableperformance from every HighCapacity unit. The continuousduty, three-phase Franklin motorwith carbon bearings andstainless steel journals is theindustry standard. Theimpellers, made of moldedDelrin, and diffusers of hardcoated aluminum with a stainless
s t e e lp u m p
shaft assuret r o u b l e - f r e e
operation inmotor fuels. Dual
(180˚ opposed)3" horizontal discharge
ports provide easyinstallation, and two built-in
line check valves reduceinstallation costs. Two linepressure relief valves protect thedispenser, meters, and pipingfrom abnormal pressures fromthermal expansion. The meshscreen on the pump inletprevents large particles fromentering the unit, and the FE Petro High Capacity unit is compatible with existing highcapacity leak detectortechnology. New units are easilyconnected to field wiringwithout disassembly of the unit.
SatisfactionEver y FE Petro pump
undergoes rigorous testing andinspection before leaving ourfactory. Each and every HighCapacity pump is built to yourtank and bury specificationsand the complete assembly isperformance tested to insurethat your needs are met. AllHigh Capacity pumps are UL listed and meet therequirements of UL 79.
HIGH CAPACITY TURBINE PUMPS
HIGH CAPACITY TURBINE PUMPS
Liquid Compatibility:• Standard units compatible with fuel mixtures containing up to 15% ethanol or methanol with
gasoline and 20% MTBE, 20% ETBE, or 17% TAME with gasoline, and diesel fuels.
• Alcohol/Gasoline models (designated with AG in model number) are compatible in fuel mixturescontaining any combination of ethanol or methanol and gasoline and 20% MTBE, 20% ETBE, or 17% TAME with gasoline, and diesel fuels.
MODEL LENGTH=ETD + riser - bottom clearanceDETERMINING MODEL LENGTH
Effective Tank Diameter (ETD) is the combination of any or all of the following:Tank Diameter (to top of 6" bung)
+ Manway+ Sump Adapter
Riser to be determined by bury depth
STP-SCIII 3 Phase Smart ControllerDesigned to replace 3-Phase Magnetic Starters.
The STP-SCIII provides the following pumpprotection and performance features:• Dry run protection• Extended pump run detection• Over/under voltage• Voltage/load unbalance• Phase loss• Locked rotor• Open circuit• Alternating lead pump• Auto start of secondary pumps
on demand or in event of fault onlead pump
Available in:• 208/230V 3 Phase 60 HZ• 380-415V 3 Phase 50 HZ
To size your pump ordercorrectly, the followinginformation is needed:1. Pump Model/Horsepower?2. Effective tank (Inside)
Diameter?3. Steel or Fiberglass Tank?4. If Fiberglass:
• Manufacturer?• Single Wall or Double Wall?• Will pump mount on tank
or on manway?5. Bury Depth?6. Containment Sump?
The FE Petro Model Number isdesignated STP-A-B-C, using thecritical dimensions shownabove, where:
A=Pump HorsepowerB=Model LengthC=Riser Length
Minimum riser length=6" (3" increments)
3760 Marsh RoadMadison, WI 53718, U.S.A.Tel: +1 608 838 8786 • Fax: +1 608 838 6433Tel: USA & Canada: 1 800 225 9787Tel: Mexico: 001 800 738 7610 Email: [email protected]: www.franklinfueling.com
HIGH CAPACITY CONTROLLER OPTIONS
HOW TO ORDER
BURYDEPTH
GRADE LEVEL
EFFECTIVETANK
DIAMETER(ETD)
C
CONTAINMENTSUMP
(IF USED)
MANWAY (IF USED)
TANKINSIDE
DIAMETER
5"
A
B
4/04HCPB001
STP-CB 3/5 Magnetic StarterThe FE Petro magnetic starter incorporates
ambient compensated relays with quick tripheaters and three leg protection. It assuresproper pump motor protection.