High ambient application Made in Japan

2

Toshiba’s Super Modular Multi System (SMMS) and its unique inverter technologies have consistently delivered comfort, energy efficiency, and reliability to satisfied customers in markets around the world.

TOULOUSE / FRANCE HIROSHIMA / JAPAN

PRAGUE / CZECH REPUBLIC CHIBA / JAPAN

BAKU / AZERBAIJANROME / ITALY BRISBANE / AUSTRALIA

DELHI / INDIA

SEOUL / KOREA

Andromede office building Hiroshima Municipal Baseball Stadium(MAZDA Zoom-Zoom Stadium Hiroshima)

Vodafone Czech Republic Mitsui Shopping ParkLaLaport KASHIWANOHA

Government HouseCapitolini Museum Portal Commercial Development

Hero Honda Motors Ltd.

Jae Neung Education Building

1 7

3 9

52 8

4

6

12

3

46 7

8

911

5

564HP 716HP 647HP

350HP

2200HP

1340HP

3000HP

14HP

262HP

3

Welcoming in a breath of fresh air

Leading the world with next-generation quality

YOKOHAMA / JAPAN

SÃO PAULO / BRAZIL

Toshiba Power Systems CompanyYokohama Office

Soccer Museum - Pacaembu Stadium2200HP

10

10

11

The all-new SMMS lineupNow also available for high ambient environments, up to 52°C

1330HP

4

The next-generation‘ -quality’ trio

Dedication to innovation and advanced intelligence fosters the imaginative creativity with which we deliver total value in air conditioning systems.

Industry-leading energy savings

New intelligent VRF control

Energy-efficient performance for greater environmental friendliness

Total system control and consistent room-to-room temperature

Toshiba’s newly developed intelligent VRF control ensures that the right amount of refrigerant to satisfy the demands of each room, regardless of the type of indoor unit used and the length of the pipes.

1

2

3

4

5

8HP 10HP 12HP 14HP

EER

T1 Conditions

T3 Conditions

Undersupplied Oversupplied

Without intelligent VRF control With intelligent VRF control

Can be adjusted to maintain consistent temperature

Innovation, Intelligence, Imagination

4,15

3,51 3,78 3,773,51 3,55 3,48

3,61

Industry

No.1 EER@

High ambient

Adopting the highly efficient new DC twin-rotary compressors and advanced vector-controlled inverters realizes high EERs and COPs at rated T1 and T3 conditions

Greater operating performance is now possible when operating under a constant load.

5

Industry-leading pipe length for greater flexibility

Greater support for height differences between indoor units

Integration with air handling units

Layout flexibility with few design limitations

System layouts can use a maximum equivalent distance of up to 235 meters. This makes it much easier to design for floors with many small rooms, or for tenants who often rearrange their floor layouts.

As of December 2009 (according to in-house studies)

Toshiba SMMSi leads the industry with support for height differences of up to 40 meters between indoor units on a single system. That is enough height to cover an 11-story building.

As of December 2009 (according to in-house studies)

The flexibility means that virtually any imaginable configuration of the refrigerant Y-type branches and/or header piping can be used in an application to give the shortest, most cost-effective piping installation.

New SMMSicoverage

achieved by a single system

Farthest equivalent length 235 m

Height between indoor units

Sing

le s

yste

m

40 m

Calculated at 3.5 meters per floor

Header after header and Y-joint after header installations are unique to Toshiba VRF

CDU

Y joint

Header Branch

CDU

Header Branch

DX coil kit to connect the SMMSi to an AHU for a fresh air supply

Currently, fresh air intake is normally achieved using be-spoked stand-alone air handling units. These third party AHU’s pre-condition the ambient fresh air to roughly match that of the conditioned space.

The Direct Expansion Coil Interface (DX) enables the connection of a TOSHIBA Outdoor unit to a third party Air Handling Unit (AHU) for fresh air intake.

PipingOutdoor Unit

Controller

Air Handling Unit (field supplied)

AHU DX Controller (MMD-DXC010)

Indoor Unit

Valve kit to be connected to R410A AHU coilMMD-DXV080 (up to 8kW)MMD-DXV140 (up to 14kW)MMD-DXV280 (up to 28kW)

Operating range: Cooling coil “Air on” temp 15°C WB ÷ 24°C WB / Heating coil “Air on” temp 15°C DB ÷ 28°C DB

Industry

No.1

Industry

No.1

6

The industry first! Introducing high-performance outdoor units with compressors and inverters

New DC twin-rotary compressor *1*2

Leading the world with Toshiba’s own new DC twin-rotary compressor

Three new DC twin-rotary compressors that feature outstanding capacity under partial load drive the 14 HP outdoor unit models, while two are used by the other outdoor unit models. These new compressors improve both energy efficiency and comfort levels.

New DC twin-rotary compressorOptimization of discharge port positioning and blade thickness reduces compression loss and friction resistance. Increasing the surface area of the rotor magnets and the addition of slits realize greater efficiency and reduced noise.

Twin-rotaryEach motor employs a compact and powerful magnetic rotor (rare earth magnet) and features reduced eddy-current loss.

Fast-calculating vector-controlled inverter *1*2

All-inverter control realizes finer control over operation to match the load on the system

Smooth sine curveThe fast-calculating vector-controlled inverter produces a smooth sine curve that improves operating efficiency.

Circuit boardThe vector-controlled inverter quickly converts current into a smooth sine curve to achieve smoother operation of the compressor’s DC motor.

Infinity variable control

Ultra-precise 0.1 Hz control over compressor rotation speed

Infinity variable control adjusts compressor rotation speed in near-seamless 0,1 Hz steps. Responding precisely to the capacity needs of the moment, this fine control minimizes energy loss when changing frequencies, and also creates a comfortable environment subject to minimal temperature variations.

Former SMMS New SMMSi

Com

pres

sor H

z

Com

pres

sor H

z

Capacity Capacity

(14HP)

Improved motor efficiency

Redesigned compression path

Greater parts protection

*1 14 model *2 As of December 2009 (according to in-house studies)

NEW

NEWThe Industry

1st*2

7

Model Name 50Hz

(MMY-)

Model Name60Hz

(MMY-)

Cooling capacity

kW

Heating capacity

kWAppearance

8 HP MAP0804HT8-E MAP0804HT7 22,4 25,0

10 HP MAP1004HT8-E MAP1004HT7 28,0 31,5

12 HP MAP1204HT8-E MAP1204HT7 33,5 37,5

14 HP MAP1404HT8-E MAP1404HT7 40,0 45,0

16 HP AP1624HT8-E AP1624HT7 45,0 50,0

18 HP AP1824HT8-E AP1824HT7 50,4 56,5

20 HP AP2024HT8-E AP2024HT7 56,0 63,0

22 HP AP2224HT8-E AP2224HT7 61,5 69,0

24 HP AP2424HT8-E AP2424HT7 68,0 76,5

26 HP AP2624HT8-E AP2624HT7 73,0 81,5

28 HP AP2824HT8-E AP2824HT7 78,5 88,0

30 HP AP3024HT8-E AP3024HT7 85,0 95,0

32 HP AP3224HT8-E AP3224HT7 90,0 100,0

34 HP AP3424HT8-E AP3424HT7 96,0 108,0

36 HP AP3624HT8-E AP3624HT7 101,0 113,0

38 HP AP3824HT8-E AP3824HT7 106,5 119,5

40 HP AP4024HT8-E AP4024HT7 112,0 127,0

42 HP AP4224HT8-E AP4224HT7 118,0 132,0

44 HP AP4424HT8-E AP4424HT7 123,5 138,0

46 HP AP4624HT8-E AP4624HT7 130,0 145,0

48 HP AP4824HT8-E AP4824HT7 135,0 150,0

790

755

780

1210

920

1830

1595

790

755

780

990

700

1830

1595

Outdoor unit specifications

1 based on an indoor air temperature of 27°C db/19°C wb and an outdoor air temperature of 35°db2 based on an indoor air temperature of 20°C db and an outdoor air temperature of 7°db/6°C wb3 based on an indoor air temperature of 27°C db/19°C wb and an outdoor air temperature of 46°C db/24°C wb4 if outdoor units are combined, refer to the installation manual5 The unit operates down to an outdoor temperature of -20°C, however considerable performance decrease will

be expected below -15°C. Consider installation location/surroundings and system design when expected to operate between -15°C and -20°C.”

6 Less than 34HP or less combination : 300m7 if the height difference between indoor units exceeds 3 m and if the indoor unit is above, max, lift is reduced

to 30 m8 Delivered capacity at 52°C Outdoor conditions is highly decreased

4-15x20 (long hole)

(Anchor bolt pitch)

(Including attached legs)

Outdoor unit (HP) 50Hz MMY- MAP0804HT8-E MAP1004HT8-E MAP1204HT8-E MAP1404HT8-E

60Hz MMY- MAP0804HT7 MAP1004HT7 MAP1204HT7 MAP1404HT7

8 HP 10 HP 12 HP 14 HP

Rated Cooling capacity @T11 kW 22,4 28,0 33,5 40

Power input kW C 5,40 7,41 9,55 11,50

EER W/W 4,15 3,78 3,51 3,48

Rated Heating capacity @T12 kW 25,0 31,5 37,5 45,0

Power input kW H 5,53 7,50 10,20 11,20

COP W/W 4,52 4,20 3,68 4,02

Maximum overcurrent protection4 A 32 32 40 40

Rated Cooling capacity @T33 kW 15,9 18,2 20,0 23,0

Power input kW C 4,53 4,83 5,63 6,37

EER W/W 3,51 3,77 3,55 3,61

Air Flow m3/h - l/s 9900 - 2750 10500 - 2917 11600 - 3222 12000 - 3333

Sound Power Level dB(A) H 78 79 83 83

Sound pressure level dB(A) H 56 58 62 62

Maxi External Static pressure available Pa 60 60 0 0

Dimensions (h x w x d) - 50Hz units mm 1830 x 990 x 780 1830 x 990 x 780 1830 x 990 x 780 1830 x1210 x 780

Dimensions (h x w x d) - 60Hz units mm 1800 x 990 x 780 1800 x 990 x 780 1800 x 990 x 780 1800 x1210 x 780

Weight kg H 242 242 242 330

Compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary

Refrigerant charge R410A kg 11,5 11,5 11,5 11,5

Suction line type - diameter Brazed - 7/8" Brazed - 7/8" Brazed - 1-1/8" Brazed - 1-1/8"

Liquid line type - diameter Flare - 1/2" Flare - 1/2" Flare - 1/2" Flare - 5/8"

Farthest piping equivalent length m 235 235 235 235

Farthest piping actual length6 m 190 190 190 190

Maximum pipe length m 500 500 500 500

Maximum lift (indoor unit above/below)7 m 70/40 70/40 70/40 70/40

Operating range - db8 °C C -5÷52 -5÷52 -5÷52 -5÷52

Operating range - wb5 °C H -20÷15 -20÷15 -20÷15 -20÷15

Power supply - 50 Hz units V-ph-Hz 380/415-3-50 380/415-3-50 380/415-3-50 380/415-3-50

Power supply - 60Hz units V-ph-Hz 380-3-60 380-3-60 380-3-60 380-3-60

Combinations Dimensions

Technical data

8HP, 10HP, 12HP 14HP

Data are in mm 60Hz models are 1800mm of height

Note: Data in the above tables are subjected to chance at any time

Model Type Model Name Capacity Code

Cooling cap. (kW)

Heating cap. (kW)

Slim Duct MMD-AP0074SPH-E MMD-AP0094SPH-E MMD-AP0124SPH-E MMD-AP0154SPH-E MMD-AP0184SPH-E

0,801,001,251,702,00

2,202,803,604,505,60

2,503,204,005,006,30

Under-ceiling MMC-AP0154H-E MMC-AP0184H-E MMC-AP0244H-E MMC-AP0274H-E MMC-AP0364H-E MMC-AP0484H-E

1,702,002,503,004,005,00

4,505,607,108,00

11,2014,00

5,006,308,009,00

12,5016,00

High-wall compact

MMK-AP0074H-E MMK-AP0094H-E MMK-AP0124H-E

0,801,001,25

2,202,803,60

2,503,204,00

High-wall MMK-AP0073H MMK-AP0093H MMK-AP0123H MMK-AP0153H MMK-AP0183H MMK-AP0243H

0,801,001,251,702,002,50

2,202,803,604,505,607,10

2,503,204,005,006,308,00

Floor standing cabinet type MML-AP0074H-E MML-AP0094H-E MML-AP0124H-E MML-AP0154H-E MML-AP0184H-E MML-AP0244H-E

0,801,001,251,702,002,50

2,202,803,604,505,607,10

2,503,204,005,006,308,00

Floor standing Concealed type MML-AP0074BH-E MML-AP0094BH-E MML-AP0124BH-E MML-AP0154BH-E MML-AP0184BH-E MML-AP0244BH-E

0,801,001,251,702,002,50

2,202,803,604,505,607,10

2,503,204,005,006,308,00

Tall floor-standing MMF-AP0154H-E MMF-AP0184H-E MMF-AP0244H-E MMF-AP0274H-E MMF-AP0364H-E MMF-AP0484H-E MMF-AP0564H-E

1,702,002,503,004,005,006,00

4,505,607,108,00

11,2014,0016,00

5,006,308,009,00

12,5016,0018,00

Bi-flow Console MML-AP0074NH-EMML-AP0094NH-EMML-AP0124NH-EMML-AP0154NH-EMML-AP0184NH-E

0,801,001,251,702,00

2,202,803,604,505,60

2,503,204,005,006,30

Febr

uary

201

2 –

The

man

ufac

ture

r res

erve

s the

righ

t to

chan

ge th

e pr

oduc

t spe

cific

atio

ns, d

ata

and

imag

es w

ithou

t not

ice.

Model Type Model Name Capacity Code

Cooling cap. (kW)

Heating cap. (kW)

4-way cassette MMU-AP0092H MMU-AP0122H MMU-AP0152H MMU-AP0182H MMU-AP0242H MMU-AP0272H MMU-AP0302H MMU-AP0362H MMU-AP0482H MMU-AP0562H

1,001,251,702,002,503,003,204,005,006,00

2,803,604,505,607,108,009,00

11,2014,0016,00

3,204,005,006,308,009,00

10,0012,5016,0018,00

Compact 4-way cassette MMU-AP0074MH-E MMU-AP0094MH-E MMU-AP0124MH-E MMU-AP0154MH-E MMU-AP0184MH-E

0,801,001,251,702,00

2,202,803,604,505,60

2,503,204,005,006,30

2-way cassette MMU-AP0072WH MMU-AP0092WH MMU-AP0122WH MMU-AP0152WH MMU-AP0182WH MMU-AP0242WH MMU-AP0272WH MMU-AP0302WH MMU-AP0302WH MMU-AP0302WH MMU-AP0302WH

0,801,001,251,702,002,503,003,204,005,006,00

2,202,803,604,505,607,108,009,00

11,2014,0016,00

2,503,204,005,006,308,009,00

10,0012,5016,0018,00

1-way cassette MMU-AP0074YH-E MMU-AP0094YH-E MMU-AP0124YH-E MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E

0,801,001,251,702,002,50

2,202,803,604,505,607,10

2,503,204,005,006,308,00

Concealed duct, stand type MMD-AP0074BH-E MMD-AP0094BH-E MMD-AP0124BH-E MMD-AP0154BH-E MMD-AP0184BH-E MMD-AP0244BH-E MMD-AP0274BH-E MMD-AP0304BH-E MMD-AP0364BH-E MMD-AP0484BH-E MMD-AP0564BH-E

0,801,001,251,702,002,503,003,204,005,006,00

2,202,803,604,505,607,108,009,00

11,2014,0016,00

2,503,204,005,006,308,009,00

10,0012,5016,0018,00

Concealed duct, high static pressure MMD-AP0184H-E

MMD-AP0244H-E MMD-AP0274H-E MMD-AP0364H-E MMD-AP0484H-E MMD-AP0724H-E MMD-AP0964H-E

2,002,503,004,005,008,00

10,00

5,607,108,00

11,2014,0022,4028,00

6,308,009,00

12,5016,0025,0031,50

Indoor units range