Upload
others
View
18
Download
0
Embed Size (px)
Citation preview
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
1
HHD-B
40.5kV 3034013.6.3 - 20 38
3033913.40 - 63 36
3034213.50 - 63 38 3034113.25 - 40 38
3028713.80 - 125 34 3028813.20 - 63 34
3033813.16 - 31.5 36
38.5kV 3033713.6.3 - 10 36
3029513.20 - 25 30 3001613.31.5 - 40 32
20 / 36kV 3045413.6.3 - 16 28 3018113.6.3 - 16 30 3000813.6.3 - 25 32
27kV 3028913.6.3 - 16 34
3002413.50 - 100 32
3001413.50 - 80 24 3020413.50 - 80 263022513.20 - 63 22
10 / 24kV3018013.6.3 - 16 22 3000613.6.3 - 40 24 3020313.6.3 - 40 26
3002214.200 24 3019614.200 26 3002213.100 - 160 24 3019613.100 - 160 26
18 3023213.50 - 80 20 3022113.20 - 63 16 3017713.31.5 - 63
10 / 17.5kV 3025513.6.3 - 16 16 3017613.6.3 - 25 18 3023113.6.3 - 40 20
18 3023314.200 20 3017814.20018 3023313.100 - 160 20 3022213.80 -160 16 3017813.80 - 160
3010213.63 - 125 12 3021113.100 - 160 14 3026713.20 - 63 8 3001213.63 - 125 10 3011913.6.3 - 16 8 3000413.6.3 - 50 10 3010113.6.3 - 50 12
3010314.200 - 250 3002014.200 - 250 10 3010313.160 12 3021114.200 - 315 14 3002013.160 10
HHD-B, DIN Style, Current-Limiting, Back-Up
Current ratings [A]; 6.3 10, 16, 20, 25, 31.5, 40, 50, 63, 80, 100, 125, 160, 200, 250, 315, 355, 400, 500
E=192mm Page E=292mm Page E=367mm Page E=442mm Page E=537mm Page
Selection Guide
6 / 12kV
3010913.63 - 125 6 3001013.63 -125 2 3009913.63 -125 4
3 / 7.2kV 3000213.6.3 - 50 2 3009813.6.3 -50 4 3010813.6.3 - 50 6
3011014.200 - 500 6 3001814.200 - 250 2 3010014.200 - 355 4 3011013.160 62 3010013.160 4 3001813.160
12
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
2
*At rated current per IEC 60282-1
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 3400101.20 100Fuse Clips w/Connecting Bar 3400201 3400102 100
2.5With 120N Striker
200 3001814.200RC140* 3.35 / 85 2.9 800 225 000 540 000 920 000 60* 2.1
600 90 000 330 000 570 000 124 160 3001813.160 3.35 / 85 2.9
Fuse Base, Indoor 3100102 3100106 98Fuse Base, Outdoor 3100201 3100206 99
1.9
Accessories
Article Description 200A > 200A Page(s)
1 000 265 000 660 000 1 100 000 70* 250 3001814.250RC160* 3.35 / 85 2.9
9.363 3001013.63 2.64 / 67 1.5 210 10 700 40 000 66 000 38 6.8
170 5 700 20 000 33 000 3050 3000213.50 2.09 / 53 1.2
47 000 180 000 390 000 98 3.3 125 2.64 / 67 1.5 390
4.8 100 3001013.100 2.64 / 67 1.5 320 33 000 130 000 210 000 60 3.8
280 21 000 78 000 140 000 4780 3001013.80 2.64 / 67 1.5
3001013.125
2725 3000213.25 2.09 / 53 1.2 90 1 050 4 700 7 500 16 21
70 640 2 900 4 800 1320 3000213.20 2.09 / 53 1.2
1740 3000213.40 1.2 140 2 900 12 000 19 000 27 13
110 1 700 6 600 12 000 21 31.5 3000213.31.5 1.2
[m ]With 80N Striker and Thermal Limiter
3000213.6.3 1.2 22 45 210 360 10 178
[A] [A2s]
TotalI2t @
0.87U(Min) 0.87Un(Max)[A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
11316 3000213.16 2.09 / 53 1.2 56 250 1 100 2 000 17 50
34 75 350 560 17 3000213.10 2.09 / 53 1.2
Size E=192mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 3/7.2kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
In Current I1 Current I3
Power Cold Current D Breaking Breaking I2 t Loss Resistance
HHD-B
2.09 / 532.09 / 53
5050
2.09 / 53 63636363636363636363636363
10 6.3
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
3
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 3/7.2kV, E = 192mm (6.3A - 250A)
3000213.6.3 - 50, 3001013.63 - 125, 30018 3.160, 3001814.200RC140 - 250RC160
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
Cut
-Off
Cur
rent
- P
eak
[kA
]
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160 A
200
RC
140 A
250
RC
160 A
H00213-301_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160 A
200
RC
140 A
250
RC
160 A
H00213-302_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
200 ARC140
250 ARC160
6,3 A
10 A
16 A
20 A25 A
31,5 A40 A
50 A
63 A
80 A100 A
125 A160 A
H00213-40_2
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
4
*At rated current per IEC 60282-1
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 3400101.20 100Fuse Clips w/Connecting Bar 3400201 3400102 100
545 000 1 060 000 1 616 000 81* 1.4 315 3.35 / 85 3.9 1 260 371 000 750 000 1 100 000 77* 1.7 250 3.35 / 85 3.9 1 000
Fuse Base, Indoor 3100302 3100306 98Fuse Base, Outdoor 3100401 3100406 99
Accessories
Article Description 200A > 200A Page(s)
825 000 1 420 000 2 225 000 89* 1.2 355 3.35 / 85 3.9 1 420
3010014.250RC180* 3010014.315RC200* 3010014.355RC225*
47 000 180 000 390 000 98 3.3 125 2.64 / 67 2.6 39028 000 130 000 210 000 58 3.8 100 2.64 / 67 2.6 320
With 120N Striker 200 3.35 / 85 3.9 800 230 000 480 000 704 000 74* 2.1
90 000 330 000 570 000 103 2.5 160 3.35 / 85 3.9 600 3009913.125 3009913.100
3010013.160
3010014.200RC160*
5 700 20 000 33 000 30 9.350 2.09 / 53 1.6 170 2 900 12 000 19 000 27 1340 2.09 / 53 1.6 140
21 000 78 000 140 000 47 4.880 2.64 / 67 2.6 280 10 700 40 000 66 000 34 6.863 2.64 / 67 2.6 210
3009813.40 3009813.50 3009913.63 3009913.80
640 2 900 4 800 13 2720 2.09 / 53 1.6 70 250 1 100 2 000 17 5016 2.09 / 53 1.6 56
1 700 6 600 12 000 21 17 31.5 1.6 110 1 050 4 700 7 500 16 2125 2.09 / 53 1.6 90
3009813.16 3009813.20 3009813.25 3009813.31.5
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
75 350 560 17 11310 2.09 / 53 1.6 34
[m ]With 80N Striker and Thermal Limiter
6.3 1.6 22 45 210 360 10 178
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=292mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 3/7.2kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
3009813.6.3 3009813.10
HHD-B
2.09 / 53
2.09 / 53636363636363636363636363
50
63
505050
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
5
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 3/7.2kV, E = 292mm (6.3A - 355A)
3009813.6.3 - 50, 3009913.63 - 125, 3010013.160, 3010014.200RC160 - 355RC225
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160 A
200
RC
160 A
250
RC
180 A
315
RC
200 A
355
RC
225 A
H00213-301-1_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160 A
200
RC
160 A
250
RC
180 A
315
RC
200 A
355
RC
225 A
H00213-302-1_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
20 A25 A
31,5 A40 A
50 A
63 A
80 A100 A
125 A160 A
200 ARC160
250 ARC180
315 ARC200
355 ARC225
H00213-41_2
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
6
*At rated current per IEC 60282-1
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 3400101.20 100Fuse Clips w/Connecting Bar 3400201 3400102 100
Fuse Base, Indoor 3110102 3110106 98Fuse Base, Outdoor Contact SIBA 99
Accessories
Article Description 200A > 200A Page(s)
1.1 500 3011014.500RC355* 3.35 / 85 5.7 50 2 000 1 668 000 3 160 000 4 500 000 176* 0.85
1 000 000 1 900 000 2 528 000 165* 400 3011014.400RC315*
2.1 250 3011014.250RC225* 3.35 / 85 5.7 50 1 000 371 000 750 000 1 100 000 145* 1.7
800 230 000 480 000 704 000 121 200 3011014.200 3.35 / 85 5.7 50
3.35 / 85 5.7 50
1.4 355 3011014.355RC250* 3.35 / 85 5.7 50 1 420 825 000 1 420 000 2 225 000 154* 1.2
1 260 545 000 1 060 000 1 616 000 143* 315 3011014.315RC250* 3.35 / 85 5.7 50
4.8 100 3010913.100 2.64 / 67 3.7 320 33 000 130 000 210 000 58 3.8
280 21 000 78 000 140 000 4780 3010913.80 2.64 / 67 3.7
3.3
With 120N Striker 160 3011013.160 3.35 / 85 5.7 63 600 90 000 330 000 570 000 98 2.3
390 47 000 180 000 390 000 85 125 3010913.125 2.64 / 67 3.7
1740 3010813.40 2.09 / 53 2.6 140 2 900 12 000 19 000 27 13
110 1 700 6 600 12 000 21 31.5 3010813.31.5 2.6
9.363 3010913.63 2.64 / 67 3.7 210 10 700 40 000 66 000 34 6.8
170 5 700 20 000 33 000 3050 3010813.50 2.09 / 53 2.6
11316 3010813.16 2.09 / 53 2.6 56 250 1 100 2 000 17 50
34 75 350 560 17 3010813.10 2.09 / 53 2.6
2725 3010813.25 2.09 / 53 2.6 90 1 050 4 700 7 500 16 21
70 640 2 900 4 800 1320 3010813.20 2.09 / 53 2.6
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
3010813.6.3 2.6 22 45 210 360 10 178
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=442mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 3/7.2kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
HHD-B
2.09 / 53
2.09 / 53
636363636363636363636363
1 600
10 6.3
3100601
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
7
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 3/7.2kV, E = 442mm (6.3A - 500A)
3010813.6.3 - 50, 3010913.63 - 125, 3011013.160, 3011014.200 - 500RC355
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
Virt
ual P
re-a
rcin
g tim
e - [
s]
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160 A
200
RC
160 A
250
RC
180 A
315
RC
200 A
355
RC
225 A
400
RC
315 A
500
RC
355 A
H00213-301-2_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160 A
200
RC
160 A
250
RC
180 A
315
RC
200 A
355
RC
225 A
400
RC
315 A
500
RC
355 A
H00213-302-2_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A10 A
16 A
20 A25 A
31,5 A40 A
50 A
63 A
80 A100 A
125 A160 A
200 A250 ARC225
315 ARC250
355 ARC250400 ARC315
500 ARC355
H00213-42_1
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
8
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 3400101.20 100Fuse Clips w/Connecting Bar 3400201 3400102 100
2.64 / 67 1.5 63
2940 3026713.40 2.64 / 67 1.5 63 140 2 900 12 000 19 000 50 22
110 1 700 6 600 12 000 38 31.5 3026713.31.5 2.64 / 67 1.5 63
Fuse Base, Indoor Contact SIBA 98Fuse Base, Outdoor Contact SIBA 99
Accessories
Article Description 200A > 200A Page(s)
1663 3026713.63 2.64 / 67 1.5 63 210 10 700 40 000 66 000 63 12
170 5 700 20 000 33 000 5650 3026713.50
18916 3011913.16 2.09 / 53 1.2 63 56 250 1 100 2 000 28 87
34 75 350 560 2810 3011913.10 2.09 / 53 1.2 63
4625 3026713.25 2.64 / 67 1.5 63 90 1 050 4 700 7 500 29 36
70 640 2 900 4 800 2320 3026713.20 2.64 / 67 1.5 63
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3011913.6.3 2.09 / 53 1.2 63 22 45 210 360 16 297
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=192mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 6/12kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
HHD-B
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
9
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 6/12kV, E = 192mm (6.3A - 63A)
3011913.6.3 - 16, 3026713.20 - 63
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
H00413-301-2_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
H00413-302-2_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
20 A25 A
31,5 A40 A
50 A
63 A
H00413-42_1
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
10
*At rated current per IEC 60282-1
Fuse Base, Indoor 3100302 3100306 98Fuse Base, Outdoor 3100401 3100406 99
3.2
Accessories
Article Description 200A > 200A Page(s)
1 000 265 000 540 000 930 000 92* 250 3002014.250RC140* 3.35 / 85 3.9 50
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 3400101.20 100Fuse Clips w/Connecting Bar 3400201 3400102 100
2.6 63
8.5 100 3001213.100 2.64 / 67 2.6 63 320 28 000 97 000 210 000 104 6.5
280 21 000 64 000 140 000 7680 3001213.80 2.64 / 67 2.6 63
With 120N Striker 200 3002014.200RC125* 3.35 / 85 3.9 50 800 227 000 465 000 800 000 91* 3.6
5.53002013.160RC125* 3.35 / 85 3.9 63 600 78 000 350 000 615 000 96* 4.2
390 38 000 138 000 300 000 159 125 3001213.125 2.64 / 67
2840 3000413.40 2.09 / 53 1.6 63 140 2 900 12 000 19 000 50 22
110 1 700 6 600 12 000 38 31.5 3000413.31.5 2.09 / 53 1.6 63
1663 3001213.63 2.64 / 67 2.6 63 210 10 700 40 000 66 000 63 12
170 5 700 20 000 33 000 5650 3000413.50 2.09 / 53 1.6 63
18916 3000413.16 2.09 / 53 1.6 63 56 250 1 100 2 000 28 84
34 75 350 560 2810 3000413.10 2.09 / 53 1.6 63
4525 3000413.25 2.09 / 53 1.6 63 90 1 050 4 700 7 500 29 34
70 640 2 900 4 800 2320 3000413.20 2.09 / 53 1.6 63
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3000413.6.3 2.09 / 53 1.6 63 22 45 210 360 16 297
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=292mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) For air & gas-insulated switchgear, DIN 43 6256/12kV - Rated Voltage
HHD-B
160
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
11
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 6/12kV, E = 292mm (6.3A - 250A)
3000413.6.3 - 50, 3001213.63 - 125, 3002013.160RC125, 3002014.200RC125 - 250RC140
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
200
RC
125 A
250
RC
140 A
160
RC
125 A
H00413-301_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
200
RC
125 A
250
RC
140 A
160
RC
125 A
H00413-302_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A10 A
16 A
20 A25 A
31,5 A40 A
50 A
63 A
80 A100 A
125 A
160 ARC125
200 ARC125
250 ARC140
H00413-40_2
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
12
*At rated current per IEC 60282-1
Fuse Base, Outdoor Contact SIBA Contact SIBA 99
2.6
Accessories
Article Description 200A > 200A Page(s)
1 000 405 000 850 000 1 500 000 139* 250 3010314.250RC200* 3.35 / 85 5.7 50
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 3400101.20 100Fuse Clips w/Connecting Bar 3400201 3400102 100
13.2kV Current-Limiting Back-Up 125 3046913.125 3.35 / 85 5.7 63 Contact SIBA
With 120N Striker 200 3010314200RC180* 3.35 / 85 5.7 50 800 310 000 630 000 1 200 000 134* 3.0
5.5 160 3010313.160 3.35 / 85 5.7 63 600 78 000 350 000 615 000 172 4.1
390 38 000 133 000 300 000 127 125 3010213.125 2.64 / 67
Fuse Base, Indoor 3110102 3110106 98
1663 3010213.63 2.64 / 67 3.7 63 210 10 700 40 000 66 000 58 12
170 5 700 20 000 33 000 5450 3010113.50 2.09 / 53 2.3 63
3.7 63
8.5 100 3010213.100 2.64 / 67 3.7 63 320 28 000 97 000 210 000 96 6.5
280 21 000 64 000 140 000 7080 3010213.80 2.64 / 67 3.7 63
4625 3010113.25 2.09 / 53 2.3 63 90 1 050 4 700 7 500 28 36
70 640 2 900 4 800 2220 3010113.20 2.09 / 53 2.3 63
2940 3010113.40 2.09 / 53 2.3 63 140 2 900 12 000 19 000 48 22
110 1 700 6 600 12 000 37 31.5 3010113.31.5 2.09 / 53 2.3 63
[m ]With 80N Striker and Thermal Limiter
6.3 3010113.6.3 2.09 / 53 2.3 63 22 45 210 360 16 297
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
18916 3010113.16 2.09 / 53 2.3 63 56 250 1 100 2 000 19 87
34 75 350 560 2810 3010113.10 2.09 / 53 2.3 63
Size E=442mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) For air & gas-insulated switchgear, DIN 43 625
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
6/12kV - Rated Voltage
HHD-B
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
13
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 6/12kV, E = 442mm (6.3A - 250A)
3010113.6.3 - 50, 3010213.63 - 125, 3010313.160, 3010314.200RC180 - 250RC200
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160 A
200
RC
180 A
250
RC
200 A
H00413-301-2_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
200
RC
125 A
250
RC
140 A
160
A
H00413-302-1_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
20 A25 A
31,5A40 A
50 A
63 A
80 A100 A
125 A
160 A
200 ARC180
250 ARC200
H00413-41_2
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
14
*At rated current per IEC 60282-1
Microswitch fittings 97
Dimensions [mm]
Fuse Clips 3100302.20 3400101.20 100Fuse Clips w/Connecting Bar 3400201 3400102 100
Fuse Base, Indoor 3100702 3100706 98Fuse Base, Outdoor Contact SIBA Contact SIBA 99
Accessories
Article Description 200A > 200A Page(s)
2.6 315 3021114.315RC225* 3.35 / 85 6.8 50 1 260 580 000 1 100 000 2 000 000 187* 2.2
1 000 405 000 850 000 1 590 000 185* 250 3021114.250RC212*
125 3021113.125 3.35 / 85 6.8 63
[m ]With 80N Striker and Thermal Limiter
100 3021113.100 3.35 / 85 6.8 63 320 33 000 130 000 210 000 96 6.5
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
3.35 / 85 6.8 50
With 120N Striker 200 3021114.200RC180* 3.35 / 85 6.8 50 800 310 000 630 000 1 200 000 163* 3.0
5.5 160 3021113.160 3.35 / 85 6.8 63 600 78 000 350 000 615 000 172 3.9
390 47 000 180 000 390 000 147
Size E=537mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 6/12kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
HHD-B
250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
15
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 6/12kV, E = 537mm (100A - 250A)
3021113.100 - 160, 3021114.160 - 250RC225
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
Virt
ual P
re-a
rcin
g tim
e - [
s]
HHD-B
x x250
RC
212 A
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
100 A
125 A
160 A
200
RC
180 A
250
RC
212 A
315
RC
225 A
H00413-301-3_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
100 A
125 A
200
RC
125 A
250
RC
140 A
160
A
315
RC
225 A
H00413-302-3_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
100 A125 A
160 A
200 ARC180250 ARC212
315 ARC225
H00413-43_1
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
16
For air & gas-insulated switchgear,
*At rated current per IEC 60282-1
Microswitch fittings 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
3.9 63
11 100 3022213.100 3.9 63 320 28 000 120 000 250 000 165 8.5
280 17 500 74 000 155 000 13780 3022213.80 3.9 63
Fuse Base, Indoor 3122101 3122106 98Fuse Base, Outdoor Contact SIBA 99
Accessories
Article Description 200A > 200A Page(s)
7.3 160 3022213.160RC100* 3.35 / 85 3.9 63 600 42 000 173 000 375 000 96* 6.6
390 38 000 160 000 337 000 235 125 3022213.125
3940 3022113.40 2.64 / 67 2.6 63 140 2 900 12 000 19 000 84 29
110 1 700 6 600 12 000 65 31.5 3022113.31.5 2.64 / 67 2.6 63
2163 3022113.63 2.64 / 67 2.6 63 210 10 700 40 000 66 000 106 16
170 5 700 20 000 33 000 10150 3022113.50 2.64 / 67 2.6 63
25216 3025513.16 2.09 / 53 1.6 63 56 250 1 100 2 000 37 116
34 75 350 560 3810 3025513.10 2.09 / 53 1.6 63
6225 3022113.25 2.64 / 67 2.6 63 90 1 050 4 700 7 500 56 48
70 640 2 900 4 800 4020 3022113.20 2.64 / 67 2.6 63
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3025513.6.3 2.09 / 53 1.6 63 22 45 210 360 21 397
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=292mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 10/17.5kV - Rated Voltage DIN 43 625
HHD-B
250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
3.35 / 853.35 / 853.35 / 85
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
17
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 10/17.5kV, E = 292mm (6.3A - 160A)
3025513.6.3 - 63, 3022213.80 - 160RC100
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160
RC
100 A
H17613-301-1_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160
RC
100 A
H17613-302-1_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A10 A
16 A
20 A25 A
31,5A40 A
50 A
63 A80 A
100 A125 A
160 ARC100
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
18
For air & gas-insulated switchgear,
*At rated current per IEC 60282-1
Fuse Base, Indoor Contact SIBA 98Fuse Base, Outdoor Contact SIBA 99
Accessories
Article Description 200A > 200A Page(s)
With 120N Striker 200 3017814.200RC125* 3.35 / 85 4.8 63 800 78 000 360 000 595 000 118* 5.2
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
11 100 3017813.100 3.35 / 85 4.8 63 320 28 000 134 000 215 000 157 8.5
280 17 500 74 000 135 000 13780 3017813.80 3.35 / 85 4.8 63
6.6 160 3017813.160RC112* 3.35 / 85 4.8 63 600 62 000 290 000 475 000 116* 6.4
390 47 000 225 000 360 000 190 125 3017813.125 3.35 / 85 4.8 63
3940 3017713.40 2.64 / 67 3.1 63 140 2 900 12 000 19 000 84 29
110 1 700 6 600 12 000 65 31.5 3017713.31.5 2.64 / 67 3.1 63
2163 3017713.63 2.64 / 67 3.1 63 210 10 700 40 000 66 000 106 16
170 5 700 20 000 33 000 10150 3017713.50 2.64 / 67 3.1 63
25216 3017613.16 2.09 / 53 2.0 63 56 250 1 100 2 000 37 116
34 75 350 560 3810 3017613.10 2.09 / 53 2.0 63
6225 3017613.25 2.09 / 53 2.0 63 90 1 050 4 700 7 500 56 48
70 640 2 900 4 800 4020 3017613.20 2.09 / 53 2.0 63
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3017613.6.3 2.09 / 53 2.0 63 22 45 210 360 21 397
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=367mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 10/17.5kV - Rated Voltage DIN 43 625
HHD-B
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
19
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 10/17.5kV, E = 367mm (6.3A - 200A)
3017613.6.3 - 25, 3017713.31.5 - 63, 3017813.100 - 160RC112, 30178 4.200RC125
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
x
XX
X
X
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160
RC
112 A
200
RC
125 A
H17613-301_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
200
RC
125 A
160
RC
112 A
H17613-302_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
200 ARC140
250 ARC160
6,3 A
10 A
16 A
20 A25 A
31,5 A40 A
50 A
63 A
80 A100 A
125 A160 A
H00213-40_2
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
20
*At rated current per IEC 60282-1
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
7.5 160 3023313.160RC125* 3.35 / 85 5.6 63 600 62 000 290 000 475 000 142* 6.4
390 47 000 225 000 360 000 229 125 3023313.125 3.35 / 85 5.6 63
Fuse Base, Indoor 3100502 3100506 98Fuse Base, Outdoor 3100601 3100606 99
Accessories
Article Description 200A > 200A Page(s)
With 120N Striker 200 30 23314.200RC140* 3.35 / 85 5.6 63 800 78 000 360 000 595 000 148* 5.2
2163 3023213.63 2.64 / 67 3.7 63 210 10 700 40 000 66 000 106 16
170 5 700 20 000 33 000 10150 3023213.50 2.64 / 67 3.7 63
11 100 3023313.100 3.35 / 85 5.6 63 320 28 000 134 000 215 000 182 8.7
280 17 500 74 000 135 000 13780 3023213.80 2.64 / 67 3.7 63
6225 3023113.25 2.09 / 53 2.5 63 90 1 050 4 700 7 500 56 48
70 640 2 900 4 800 4220 3023113.20 2.09 / 53 2.5 63
3940 3023113.40 2.09 / 53 2.5 63 140 2 900 12 000 19 000 84 29
110 1 700 6 600 12 000 69 31.5 3023113.31.5 2.09 / 53 2.5 63
[m ]With 80N Striker and Thermal Limiter
6.3 3023113.6.3 2.09 / 53 2.5 63 22 45 210 360 21 397
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
25216 3023113.16 2.09 / 53 2.5 63 56 250 1 100 2 000 37 116
34 75 350 560 3810 3023113.10 2.09 / 53 2.5 63
Size E=442mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 10/17.5kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
HHD-B
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
21
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 10/17.5kV, E = 442mm (6.3A - 200A)
3023113.6.3 - 40, 3023213.50 - 80, 3023313.100 - 160RC125, 3023314.200RC140
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
x
XX
X
X
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
160
RC
125 A
200
RC
140 A
H17613-301-2_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
200
RC
140 A
160
RC
125 A
H17613-302-2_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A10 A
16 A
20 A25 A
31,5A40 A
50 A
63 A80 A
100 A125 A
160 ARC125
200 ARC140
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
22
Microswitch fittings 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
2.64 / 67 2.6
5340 3022513.40 2.64 / 67 2.6 140 2 900 12 000 19 000 106 43
110 1 700 6 600 12 000 72 31.5 3022513.31.5 2.64 / 67 2.6
Fuse Base, Indoor 3122101 98Fuse Base, Outdoor Contact SIBA 99
Accessories
Article Description 200A > 200A Page(s)
2963 3022513.63RC50* 2.64 / 67 2.6 210 10 700 40 000 66 000 132* 21
170 5 700 20 000 33 000 10850 3022513.50
34716 3018013.16 2.09 / 53 1.6 56 250 1 100 2 000 59 160
34 75 350 560 5210 3018013.10 2.09 / 53 1.6
8625 3022513.25 2.64 / 67 2.6 90 1 050 4 700 7 500 56 66
70 640 2 900 4 800 4620 3022513.20 2.64 / 67 2.6
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3018013.6.3 2.09 / 53 1.6 22 45 210 360 29 546
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=292mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 10/24kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
HHD-B
250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
31.5
*At rated current per IEC 60282-1
31.531.531.531.531.531.531.531.5
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
23
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 10/24kV, E = 292mm (6.3A - 63A)
3018013.6.3 - 16, 3022513.20 - 63
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
H00613-301_1
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
H00613-302-1_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 2 32 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
20 A25 A
31,5 A40 A
50 A63 A
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
24
*At rated current per IEC 60282-1
Microswitch fittings
Dimensions [mm]
Fuse Clips 3100302.20Fuse Clips w/Connecting Bar 3400201
11 160 3002213.160RC100* 3.35 / 85 5.7 63 600 62 000 237 000 395 000 146* 9
390 47 000 180 000 300 000 320 125 3002213.125 3.35 / 85 5.7 63
Fuse Base, Indoor 3100502 3100506Fuse Base, Outdoor 3100601 3100602
Accessories
Article Description 200A > 200A Page(s)
With 120N Striker3002214.200RC112* 3.46 / 88 5.7 63 800 75 000 290 000 470 000 157* 8
2963 3001413.63 2.64 / 67 3.7 63 210 10 700 40 000 66 000 132 22
170 5 700 20 000 33 000 10850 3001413.50 2.64 / 67 3.7 63
16 100 3002213.100 3.35 / 85 5.7 63 320 28 000 160 000 255 000 238 13
280 21 000 78 000 140 000 17480 3001413.80 2.64 / 67 3.7 63
8325 3000613.25 2.09 / 53 2.5 63 90 1 050 4 700 7 500 56 62
70 640 2 900 4 800 4620 3000613.20 2.09 / 53 2.5 63
5240 3000613.40 2.5 63 140 2 900 12 000 19 000 106 43
110 1 700 6 600 12 000 72 31.5 3000613.31.5 2.09 / 53 2.5 632.09 / 53
Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3000613.6.3 2.09 / 53 2.5 63 22 45 210 360 29 546
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
34716 3000613.16 2.09 / 53 2.5 63 56 250 1 100 2 000 59 151
34 75 350 560 5210 3000613.10 2.09 / 53 2.5 63
98 99
97
100 100
Size E=442mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 10/24kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking
HHD-B
250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
200
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
25
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 10/24kV, E = 442mm (6.3A - 200A)
3000613.6.3 - 40, 3001413.50 - 80, 3002213.100 - 160RC100, 3002214.200RC112
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
x
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
200
RC
112 A
160
RC
100 A
H00613-301_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
200
RC
112 A
160
RC
100 A
H00613-302_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 2 32 3 4 6 8
2
3
4
6
8
kA
6,3 A10 A
16 A
20 A25 A
31,5 A40 A
50 A63A
80 A100 A
125 A160 ARC100
200 ARC112
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
26
*At rated current per IEC 60282-1
Fuse Base, Indoor 3100706 98Fuse Base, Outdoor Contact SIBA Contact SIBA 99
Accessories
Article Description 200A > 200A Page(s)
With 120N Striker 200 3019614.200RC125* 3.35 / 85 6.8 63 800 75 000 290 000 470 000 179* 8
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
3100702
16 100 3019613.100 3.35 / 85 6.8 63 320 28 000 160 000 255 000 239 13
280 21 000 78 000 140 000 17480 3020413.80 2.64 / 67 4.3 63
11 160 3019613.160RC112* 3.35 / 85 6.8 63 600 62 000 237 000 395 000 178* 9
390 47 000 180 000 300 000 320 125 3019613.125 3.35 / 85 6.8 63
5240 3020313.40 2.09 / 53 2.8 63 140 2 900 12 000 19 000 106 41
110 1 700 6 600 12 000 72 31.5 3020313.31.5 2.09 / 53 2.8 63
2963 3020413.63 2.64 / 67 4.3 63 210 10 700 40 000 66 000 132 22
170 5 700 20 000 33 000 10850 3020413.50 2.64 / 67 4.3 63
34716 3020313.16 2.09 / 53 2.8 63 56 250 1 100 2 000 59 151
34 75 350 560 5210 3020313.10 2.09 / 53 2.8 63
8325 3020313.25 2.09 / 53 2.8 63 90 1 050 4 700 7 500 56 62
70 640 2 900 4 800 4620 3020313.20 2.09 / 53 2.8 63
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3020313.6.3 2.09 / 53 2.8 63 22 45 210 360 29 546
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=537mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 10/24kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
HHD-B
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
27
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 10/24kV, E = 537mm (6.3A - 200A)
3020313.6.3 - 40, 3020413.50 - 80, 3019613.100 - 160RC112, 3019614.200RC125
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
x
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
200
RC
112 A
160
RC
100 A
H00613-301-2_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
200
RC
125 A
160
RC
112 A
H00613-302-2_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 2 32 3 4 6 8
2
3
4
6
8
kA
16 A
20 A25 A
31,5 A40 A
50 A
63 A
80 A100 A
125 A160 ARC112
200 ARC125
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
28
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
20
[m ]Without Striker and Thermal Limiter
6.3 3045411.6.3 20 22 45 210 360 44 819
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Fuse Base, Indoor Contact SIBA 98Fuse Base, Outdoor Contact SIBA 99
Accessories
Article Description 200A > 200A Page(s)
52116 3045411.16 20 56 250 1 100 3 500 75 241
34 75 350 560 7810 3045411.10
Size E=292mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 20/36kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
HHD-B
2.64 / 672.64 / 672.64 / 67
2.62.6
2.6
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
29
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 20/36kV, E = 292mm (6.3A - 16A)
3045413.6.3 - 16
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
H00813-301-2_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
H00813-302-2_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
H00813-42_0
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
30
Microswitch fittings 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
2.64 / 67 3.7 20
52116 3018113.16 2.09 / 53 2.5 20 56 250 1 100 2 000 74 241
34 75 350 560 7810 3018113.10 2.09 / 53 2.5 20
Fuse Base, Indoor Contact SIBA 98Fuse Base, Outdoor Contact SIBA 99
Accessories
Article Description 200A > 200A Page(s)
12925 3029513.25 2.64 / 67 3.7 20 90 1 050 4 700 7 500 87 99
70 640 2 900 4 800 6620 3029513.20
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3018113.6.3 2.09 / 53 2.5 20 22 45 210 360 44 819
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=442mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 20/36kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
HHD-B
250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
31
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 20/36kV, E = 442mm (6.3A - 25A)
3018113.6.3 - 16, 3029513.20 -25
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
H00813-301-1_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
H00813-302-1_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
20 A
25 A
H00813-41_0
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
32
*At rated current per IEC 60282-1
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
Fuse Base, Indoor 3100702 3100706 98Fuse Base, Outdoor 3100801 99
Accessories
Article Description 200A > 200A Page(s)
23 100 3002413.100RC71* 3.35 / 85 6.8 40 350 33 000 130 000 210 000 162* 21
280 21 000 78 000 140 000 145* 80 3002413.80RC63*
8040 3001613.40 2.64 / 67 4.5 40 140 2 900 12 000 19 000 144 60
110 1 700 6 600 12 000 102 31.5 3001613.31.5 2.64 / 67 4.5 40
3.35 / 85 6.8 40
4463 3002413.63 3.35 / 85 6.8 40 210 10 700 40 000 66 000 224 32
170 5 700 20 000 33 000 18650 3002413.50 3.35 / 85 6.8 40
52116 3000813.16 2.09 / 53 2.7 40 56 250 1 100 2 000 79 241
34 75 350 560 7810 3000813.10 2.09 / 53 2.7 40
12925 3000813.25 2.09 / 53 2.7 40 90 1 050 4 700 7 500 87 99
70 640 2 900 4 800 6620 3000813.20 2.09 / 53 2.7 40
0.87U(Min) 0.87Un(Max)In Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3000813.6.3 2.09 / 53 2.7 40 22 45 210 360 44 819
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=537mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 20/36kV - Rated Voltage For air & gas-insulated switchgear, DIN 43 625
HHD-B
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
33
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 20/36kV, E = 537mm (6.3A - 100A)
3000813.6.3 - 25, 3001613.31.5 - 40, 3002413.50 - 100RC71
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
Virt
ual P
re-a
rcin
g tim
e - [
s]
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
100
RC
71 A
80
RC
63 A
H00813-301_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
100
RC
71 A
80
RC
63 A
H00813-302_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 22 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
20 A
25 A31,5 A
40 A
50 A63 A
80 ARC63
100 ARC71
H00813-40_1
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
34
*At rated current per IEC 60282-1
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
16 100 3028713.100 3.35 / 85 5.7 320 33 000 210 000 234 13
280 21 000 140 000 174 80 3028713.80 3.35 / 85 5.7
Fuse Base, Indoor Contact SIBA 98Fuse Base, Outdoor Contact SIBA 99
11
Accessories
Article Description 200A > 200A Page(s)
390 47 000 390 000 320 125 3028713.125 3.35 / 85 5.7
5840 3028813.40 2.64 / 67 3.7 140 2 900 19 000 109 44
110 1 700 12 000 79 31.5 3028813.31.5 2.64 / 67 3.7
3263 3028813.63 2.64/ 67 3.7 210 10 700 66 000 144 23
170 5 700 33 000 11950 3028813.50 2.64 / 67 3.7
38016 3028913.16 2.09 / 53 2.5 56 250 2 000 68 185
34 75 560 5610 3028913.10 2.09 / 53 2.5
9325 3028813.25 2.64 / 67 3.7 90 1 050 7 500 59 70
70 640 4 800 4920 3028813.20 2.64 / 67 3.7
0.87UnIn Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3028913.6.3 2.09 / 53 2.5 63 22 45 360 32 595
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=442mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 27kV - Rated Voltage[Un] For air & gas-insulated switchgear, DIN 43 625
HHD-B
6363633663366363636363
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
35
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 27kV, E = 442mm (6.3A - 125A)
3028913.6.3 - 16, 3028813.20 - 63, 3028713.80 - 125
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
H28713-301_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63 A
80 A
100 A
125 A
H28713-302_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 2 32 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
20 A25 A
31,5A40 A
50 A
63A
80 A100 A
125 A
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
36
*At rated current per IEC 60282-1
3134001
Microswitch fittings 250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
3.35 / 85 6.8 40
9340 3033913.40 3.35 / 85 6.8 40 140 2 900 19 000 152 70
110 1 700 12 000 108 31.5 3033813.31.5 2.64 / 67 4.5 40
Fuse Base, Indoor Contact SIBA 98Fuse Base, Outdoor 99
Accessories
Article Description 200A > 200A Page(s)
51 63 3033913.63RC50* 3.35 / 85 6.8 40 210 10 700 66 000 171* 30
170 5 700 33 000 19650 3033913.50
59016 3033813.16 2.64 / 67 4.5 40 56 250 2 000 85 293
34 75 560 8610 3033713.10 2.09 / 53 2.7 40
14825 3033813.25 2.64 / 67 4.5 40 90 1 050 7 500 100 114
70 640 4 800 7620 3033813.20 2.64 / 67 4.5 40
0.87UnIn Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
6.3 3033713.6.3 2.09 / 53 2.7 40 22 45 360 51 943
[W][A] Article Number
Size E=537mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 38.5kV - Rated Voltage[Un] For air & gas-insulated switchgear, DIN 43 625
HHD-B
[in/mm] [kg/1] [kA] [A] [A2s] [A2s] [A2s]
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
37
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 38.5kV, E = 537mm (6.3A - 63A)
3033713.6.3 - 10, 3033813.16 - 31.5, 3033913.40 - 63RC50
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63
RC
50 A
H33713-301-1_0
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50 A
63
RC
50 A
H33713-302-1_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 2 32 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
20 A
25 A31,5A
40 A
50 A
63 ARC50
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
38
*At rated current per IEC 60282-1
Microswitch fittings 97
Dimensions [mm]
Fuse Clips 3100302.20 100Fuse Clips w/Connecting Bar 3400201 100
3.35 / 85 6.8 40
9840 3034113.40 2.64 / 67 4.5 40 140 2 900 19 000 175 73
110 1 700 12 000 126 31.5 3034113.31.5 2.64 / 67 4.5 40
Fuse Base, Indoor Contact SIBA 98Fuse Base, Outdoor 99
Accessories
Article Description 200A > 200A Page(s)
54 63 3034213.63RC50* 3.35 / 85 6.8 40 210 10 700 66 000 181* 39
170 5 700 33 000 176*3034213.50RC45*
62016 3034013.16 2.09 / 53 4.5 40 56 250 2 000 94 285
34 75 560 8110 3034013.10 2.09 / 53 2.7 40
14525 3034113.25 2.64 / 67 4.5 40 90 1 050 7 500 103 120
70 640 4 800 7620 3034013.20 2.09 / 53 4.5 40
0.87UnIn Current I1 Current I3
Total Power Cold Current D Breaking Breaking I2 t I2t @ Loss Resistance
[m ]With 80N Striker and Thermal Limiter
2.09 / 53 2.7 40 22 45 360 52 949
[A] [A2s] [A2s] [A2s] [W][A] Article Number [in/mm] [kg/1] [kA]
Size E=537mm Back-Up Rated Diameter Weight Rated Minimum Pre-arcing
indoor and outdoor applications IEC 60282-1Class VDE 0670 - 4
HHD-B High Voltage Current-Limiting Fuses Standard(s) 40.5kV - Rated Voltage[Un] For air & gas-insulated switchgear, DIN 43 625
3134001
HHD-B
50
250mm - 3100116, 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
6.3 3034013.6.3
SIBA LLC Phone 1-973-575-7422 29 Fairfield Place e-mail: [email protected] Fax 1-973-575-5858 West Caldwell, New Jersey 07006 www.siba-fuses.us
FUSES
39
Virt
ual P
re-a
rcin
g tim
e - [
s]
R.M.S. Prospective Current [A]
Cut-Off Current
Cut
-Off
Cur
rent
- P
eak
[kA
]
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Cut-Off Current DiagramCurrent-Limiting, Back-Up, 40.5kV, E = 537mm (6.3A - 63A)
3034013.10 - 20, 3034113.25 - 40, 3034213.50RC45 - 63RC50
Minimum Melting Total Clearing
HHD-B Time-Current Characteristics - Minimum Melting and Total Clearing
HHD-B
104
103
s
102
101
100
10-1
10-2
101
2
3
4
56
8
102
103
104
105A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10 A
16 A
20 A
25 A
31,5
A
40 A
50
RC
45 A
63
RC
50 A
H34013-301_0
10 4
10 3
s
10 2
10 1
10 0
10 -1
10 -2
10 1
2
3
456
8
10 2 10 3 10 4 10A2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
6,3
A
10
A
16
A
20
A
25
A3
1,5
A
40
A
50
A6
3R
C5
0 A
H34013-302-1_0
10
10
10
10
10 10 10 10 10
kA
3
2
1
0
-1 0 1 2 32 3 4 6 8
2
3
4
6
8
kA
6,3 A
10 A
16 A
20 A25 A
31,5 A40 A
50 ARC45
63 ARC50