26
Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Embed Size (px)

Citation preview

Page 1: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Herzlich Willkommen

SEIKO Videocentration system including near PD measurement

Page 2: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Advantages Videocentrationsystem:

Frameselection

Measurement of centration data

Lens consultation

Increase of Imange, showing competence

Increase of turnover by selling higher quality lenses

and less complaints

SEIKO – Videocentrationsystem

Page 3: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

High quality digital SLR camera. 12 Megapixel, 6 x optical zoom.

Embedded PC with touchscreen

SEIKO – Videocentrationsystem

Page 4: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Advantages Videocentrationsystem:

Frame selection

SEIKO – Videocentrationsystem

Page 5: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

max. 18 photos

Series of up to 6 pictures

Simulation of lenses, tints, …

Excellent quality of images

Print-out available

Frame selection

SEIKO – Videocentrationsystem

Page 6: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Advantages Videocentrationsystem :

Frame selection

Measurement of centration data

SEIKO – Videozentrationsystem

Page 7: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Measurement of centration data

FFA with headmirrorRefernce jig

SEIKO – Videozentrationsystem

Page 8: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Frontpicture : all data for centration and optimization

Measurement of centration data

single PD boxing size fitting height

Total PD dbl Facerotation / Facetilt

Page 9: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

PD

Pupil center or cornea reflex ?

Measurement of centration data

Page 10: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

PD

Pupil center or cornea reflex ?

PD based on pupil center is in average 0,50 mm > than cornea reflex PD

Variation Pupil center PD – Cornea reflex PD: 0,0–1,0 mm

Measurement of centration data

Page 11: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Cornea Reflex PD 67,05 mm

Pupil center PD 68,08 mm

Measurement of centration data

Page 12: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

PD Messung

Pupil center PD or Cornea reflex PD?

Pupil center PD in average 0,50 mm > corena reflex PD

Variation Pupil center PD – Cornea reflex PD: 0,0–1,0 mm

Recommendation:

Validation of cornea reflex measurement using the crosses and, if necessary, adjusting according to pupil center.

Measurment of centration data

Page 13: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Frontpicture : all data for centration and optimization

FFA with headmirror

Measurement of centration data

Page 14: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Frontpicture : FFA measurement

Measurement of FFA under wearing conditions

Measurement of centration data

Page 15: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Side picture: VCD und PT

Measurement of centration data

Page 16: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Near PD measurement

Testing under reading conditions

Determination of inset for individual progressives

Measurement of centration data

Page 17: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Measurement of near PD

Page 18: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Measurement of near PD

Page 19: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Measurement of near PD

Page 20: Herzlich Willkommen SEIKO Videocentration system including near PD measurement
Page 21: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Front picture: all centration data incl. FFA

within approx. 2-3 minutes

Side picture: VCD and PT

Hand-held mirror: near PD

SEIKO – Videocentrationsystem

A complete and extremely accurate way of getting all centration data

Page 22: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Advantages Videocentrationsystem :

Frame selection

Measurement of centration data

Lens consultation

SEIKO – Videocentrationsystem

Page 23: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Lens consultation

Comparison of high-end material, design, brandproducts

SEIKO – Videocentrationsystem

Page 24: Herzlich Willkommen SEIKO Videocentration system including near PD measurement
Page 25: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

„Open“ system for all lens suppliers

SEIKO – Videocentrationsystem

Page 26: Herzlich Willkommen SEIKO Videocentration system including near PD measurement

Advantages VCS: Disadvantages VCS:

Frame selection Purchase cost

Measurement of centration data

Lens consultation

Increase of Imange, showing competence

Increase of turnover by selling higher

quality lenses and less complaints

SEIKO – Videocentrationsystem