Upload
hanga
View
213
Download
0
Embed Size (px)
Citation preview
40
HEA
TIN
G
Call 888-777-2700 for rates and reservations
HEATING
HEATING Direct Fired, Electric, Indirect Fired, Radiant + Speciality,
Flameless, Self-Contained, and Hydronic Surface
HEATING Direct Fired, Electric, Indirect Fired, Radiant + Speciality,
Flameless, Self-Contained, and Hydronic Surface
HercRentals.com 41
HEATIN
GHEATING
HEAT APPLICATION GUIDE
ELECTRIC SELF-CONTAINED
HYDRONIC SURFACEDIRECT
FLAMELESS
INDIRECT
Portable Electric Heaters Industrial Electric Heaters
Portable electric heaters provide safe, fast, dry, odorless heat for enclosed spaces. Available in ranges from 1.6 kW to 150 kW. Ideal for job sites or offices, where 100% dry heat and flameless operations are required.
Advantages• 100% clean, dry heat - no moisture • No exhaust - can be used in confined spaces• No need for gas line or propane• Quiet operation
Applications• Heating for contractors and special events• Emergency situations - heat loss, thawing of frozen pipes
Self-Contained units have a built in generator for easy start up. Tow to the site and start it up!
Advantages• Powerful - provides clean, safe, reliable air• Ducting long distances with minimal loss of pressure or temperature• Push-button controls make units easy to use• Flameless options are also available• Built-in generator
Applications• Ground thawing• Cold weather concrete warming/curing• Pre-pour warming• Ground frost prevention• Multi-zone layout: create higher return temps for a quicker more-effective thaw• Other heat applications for extreme cold
Trailer mounted hydronic heaters are self-contained so they can operate in remote job sites. Powerful burners heat up fluid that is pumped through 5/8 inch hose (the heating circuit) up to 3,000 ft in length.
Advantages• Long run times, maximized efficiency• Closed-loop system: vertically or sideways• On-board fuel heater• Spill containment and safety shut down sensors
Applications• Ground thawing• Cold weather concrete warming/curing• Pre-pour warming• Ground frost prevention• Higher return temps for a quicker thaw
Direct fired portable heaters are generally used in farms, warehouses, garages and construction sites. Proper ventilation of the heated area is necessary.
Advantages• Kerosene and propane forced air heaters are portable and easy to operate• Extends heat into wide areas for a comfortable work environment in the harshest conditions
Applications• Farms, workshops, warehouses, garages and construction sites with proper ventilation
Flameless heaters provide highly efficient heated air output with unprecedented safety in portable DOT-approved trailer mounted packages. These heaters are capable of ducting long distances with minimal loss of air pressure or outlet temperature.
Advantages• Ideal for potentially volatile applications where "no open flame" is a requirement• Develop very high CFM and static pressure to maximize heat delivery• Engine driven
Applications• Oil and Gas• Mining• Construction• Restoration
Portable indirect fired heaters operate like a mobile furnace with a fan forcing air over a heat exchanger where internal combustion occurs and fumes are exhausted through a stack.
Advantages• 100% clean, dry heat with no open flame• Exhaust vented outside• Flexible fuel options: oil, diesel, propane (LP), natural gas (NG), or dual fuel (LP/NG)
Applications• Safe for use around people and animals• Emergency situations: heating system is under repair or drying applications• Special events: ducting allows units to be placed outside and away from tents or temporary structures with warm air ducted into interior areas
42
HEA
TIN
G
Call 888-777-2700 for rates and reservations
HEATING
DIRECT FIRED
MI-T-M/MH-0150-LMTO
FLAGRO/F-1500T
150,000 BTU propane forced air
Adjustable thermostat
Requires (1) 100 lb. LP cylinder
1,500,000 BTU LP or natural gas forced air
High and low fire output heat capacity
Fuel selector valve to change fuel supply LP/NG
MI-T-M/MH-0190-0M10
190,000 BTU kerosene forced air
Fuel gauge
13 gallon on-board fuel tank
MI-T-M/MH-0375-LM10
375,000 BTU propane forced air
Adjustable thermostat
Requires (2) 100 lb. LP cylinders
FLAGRO/FMA-2300
2,300,000 BTU LP or natural gas forced air
Mild weather stat: to prevent heating in mild weather
Requires 230V 3PH 35A for fan operation
Not for use in residential living
areas or inadequately ventilated areas. Must
be plugged into an approved standard electrical outlet for
operation.
MAKE MODEL TYPE CFM BTUHEATING AREA
FUEL TANK
CONSUMPTION RUN TIME VOLTAGEDIMENSIONS (LWH)
WEIGHT (DRY)
PRO RPP
CAT-CLASS
MI-T-M MH-0150-LMTO PROPANE 400 150,000 3,800 sq ft 100 gal external 6.9 lbs/hr 18 hrs 120V 25.1" x 8" x 15.4" 23 lbs 715-0430
MI-T-M MH-0190-0M10 KEROSENE 630 190,000 4,000 sq ft13 gal on
board1.42 gal / hr 9.1 hrs 120V 42" x 24" x 26" 58 lbs 715-0450
MI-T-M MH-0375-LM10 PROPANE 1,500 375,000 9,000 sq ft (2) 100 gal external 17.4 lb/hr 11.5 hrs 120V 34" x 12.6" x 18.5" 41 lbs 715-0460
Flagro F-1500T LP/NG 7,000 1,500,000 19,000 sq ft External 16.24 gal LP / 1500 CFH
Depends on tank cap 115V 61" x 29" x 38" 314 lbs 715-0550
Flagro FMA-2300 LP/NG 15,000 2,300,000 30,000 sq ft External 25.11 gal LP / 2300 CFH
Depends on tank cap
230 Volt / 3PH / 35 Amp
96" x 47" x 51" 1,900 lbs 715-0560
[
[
HercRentals.com 43
HEATIN
GHEATING
ELECTRIC
MAKE MODEL CAPACITY CFM BTU/HOURHEATING AREA
VOLTAGE PHASE AMP RATING DIMENSIONS (LWH) WEIGHTPRO RPP
CAT-CLASS
CAMPO EB1.5E 1.5 kW 125 5,100 50 sq ft 120v 1PH 13A 10.88" x 8.33" x 12.27" 13 lbs 715-0010
DEWALT DXH165 1.65 kW 135 5,630 50 sq ft 115v 1PH 13.5A 14.5" x 11" x 13.5" 14 lbs 715-0010
PHOENIXFIREBIRD COMPACT 20
5-20 kW 250 20,000 300 sq ft 120v 1PH 12A-48A 13" x 12.5" x 26" 35 lbs 715-0020
CAMPO EB6/9E 6-9 kW 55020,500 / 30,700
750 sq ft 240v 1PH 24.5A/36.5A 23.5" x 13.5" x 17" 45 lbs 715-0030
DEWALT DXH1000TS 7-10 kW 35023,884 / 34,121
300 sq ft 240v 1PH 30A 25.3" x 14.6" x 17.7" 37 lbs 715-0030
FOSTORIA FES-1524-3E 15 kW 800 51,195 2,000 sq ft 240v 3PH 36A 23.2" x 21.4" x 39" 65 lbs 715-0040
FOSTORIA FES-1548-3E 15 kW 800 51,195 2,000 sq ft 480v 3PH 18A 23.2" x 21.4" x 39" 65 lbs 715-0045
CAMPO EB18E 18 kW 1200 65,000 1,500 sq ft 208/240v1PH - 3PH
1PH 86A/3PH 50A 35.5" x 17.5" x 20" 120 lbs 715-0046
DEWALT DXH2003TS 20 kW 60068,242 / 44,357
1,200 sq ft 240v 3PH 28A / 42A 29.5" x 16.5" x 21" 35 lbs 715-0050
FOSTORIA FES-3048-3A 30 kW 1,100 102,390 2,000 sq ft 480v 3PH 36A 23.3" x 22" x 39" 83 lbs 715-0060
CAMPO EB60E 60 kW 4,500205,000 / 136,500
5,000 sq ft 240/480v 3PH144A/240v 72A/480v
51.5" x 22" x 35.5" 300 lbs 715-0070
CAMPO EB150E480V 150 kW 14,500 512,000 15,000 sq ft 480v 3PH 87/138/196A/480v 68" x 31.5" x 56" 950 lbs 715-0245
CAMPO/ED1.5E
CAMPO/EB18E
5,100 BTU
13 AMPS
Input power required: 120V 13.5A 1PH
65,000 BTU
Built in thermostat control
Input power required 208/240 V 1PH 86A
or 3 PH 50 A
CAMPO/EB6/9E
CAMPO/EB60E
BTU 20,500/30,700 dual output
Keep second point
Input power required 24.5A/36.5A 1PH
136,500 - 205,000 BTU dual output
Recirculating capabilities
Input power required: 240/480V 144/72A 3PH
PHOENIX/FIREBIRD COMPACT 20
FOSTORIA /SALAMANDER FES-1548-3E
20,000 BTU max output
Remote thermostat
Generate 5,000 BTU per each 120V 12 Amp 1PH
102,390 BTU
3-position switch: Off/Thermostat control/
Continuous On Fan-only operation
Input power required: 480V 36A 3PH
DRY HEATDoes NOT Add Moisture to the environment
44
HEA
TIN
G
Call 888-777-2700 for rates and reservations
INDIRECT FIRED
MAKE MODELFUEL TYPE
BTU/HOUR
HEATING AREA
CFM/SPFUEL TANK
CONSUMPTION RUN TIME VOLTAGEDIMENSIONS (LWH)
WEIGHT (DRY)
PRO RPP
CAT-CLASS
Campo EB200D Diesel/K1 175,000 5,000 sq ft 3,250 / 3" 40 gal 1.25 gal/hr 32 hrs 120V 48.5” x 30.6” x 65” 250 lbs 715-0610
Flagro FVO-200RC Diesel/K1 200,000 4,700 sq ft 1,500 / 3" 23 gal 1.5 gal/hr 15 hrs 115V 53.5" x 27" x 39.5" 280 lbs 715-0610
Campo EB200G LP/NG 175,000 4,700 sq ft 3,250 / 3" External 1.9 gal LP/4.8 gal NG
depends on tank cap. 120V 48.5” x 30.6” x 65” 400 lbs 715-0615
Flagro FVNP-200RC LP/NG 200,000 4,700 sq ft 1,500 / 3" External 2.18 gal LP/200 CFH NG
depends on tank cap. 115V 51.5" x 27" x 43.5" 330 lbs 715-0615
Campo EB400D Diesel/K1 396,000 7,000 sq ft 5,500 / 3" 42 gal 2.82 gal/hr 14.9 hrs 115V 76.7” x 31” x 57.6” 550 lbs 715-0620
Flagro FVO-400RC Diesel/K1 390,000 10,000 sq ft 4,000 / 3" 42 gal 2.75 gal/hr 14 hrs 115V 70" x 29" x 54" 455 lbs 715-0620
Campo EB400G LP/NG 399,000 7,000 sq ft 5,500 / 3" External 4.46 gal LP/11.16 gal NG
depends on tank cap. 115V 76.7” x 31” x 57.6” 550 lbs 715-0630
Flagro FVNP-400RC LP/NG 390,000 10,000 sq ft 4,000 / 3" External 4.25 gal LP / 390 CFH NG
depends on tank cap. 115V 70" x 29" x 49" 470 lbs 715-0630
Campo EB600D Diesel/K1 588,000 12,000 sq ft 5,500 / 3" 42 gal 4.2 gal/hr 10 hrs 120V 76.7" x 31" x 57.6" 600 lbs 715-0631
Campo EB600G LP/NG 575,000 12,000 sq ft 5,500 / 3" External 6.39 gal LP/16.08 gal NG
depends on tank cap. 120V 76.7” x 31” x 57.6” 600 lbs 715-0632
Campo BLAZE 1000G LP/NG 1,000,000 20,000 sq ft 13,500 / 6.5" External 11.17 gal LP / 27.92 gal NG
depends on tank cap.
208/240V 1PH or 3PH 111” x 33.3” x 50” 2,000 lbs 715-0660
Campo BLAZE 2000G LP/NG 2,000,000 40,000 sq ft 16,000 / 6.5" External 22.34 gal LP / 55.84 gal NG
depends on tank cap.
208/240V 1PH or 3PH 144” x 33.3” x 67” 2,950 lbs 715-0695
CAMPO/EB200D
CAMPO/EB600G
175,000 BTU oil fired
Ductable up to 150 ft Supply, 50 ft Return
40 gallon on-board fuel tank
575,000 BTU LP/NG fired
Ductable up to 150 ft Supply, 50 ft Return
NG/LP easy switchover valve
FLAGRO/FVNP-200RC
200,000 BTU LP or natural gas fired
Recirculating capabilities to minimize fuel costs
External LP tank or NG hook-up required
FLAGRO/FVO-400RC
390,000 BTU oil fired
Recirculating capabilities
42 gallon on-board fuel tank
CAMPO/BLAZE 1000G/D CAMPO/BLAZE 2000G/D
1,000,000 BTU LP/NG fired or oil fired
Ductable up to 400 ft
Diesel burner kit available
2,000,000 BTU LP/NG fired or oil fired
Ductable up to 200 ft
Diesel burner kit available
HEATING
HercRentals.com 45
HEATIN
G
INDUSTRIAL ELECTRIC
MAKE MODEL CAPACITY BTU CFM / SP VOLTAGE PHASEAMP RATING
DIMENSIONS (LWH) WEIGHTPRO RPP
CAT-CLASS
CAPS PHUH-ONN-150KEONN 150 kW 512,000 8,000/5 in 480V 3PH 206A 96" x 48" x 50.6" 2,500 lbs 715-0240
Campo Blaze 150E 150 kW 512,000 14,500 / 6.5 in 480V 3PH 196A 68" x 31.5" x 56" 950 lbs 715-0240
CAMPO/BLAZE 150E
14,500 BTU with 6.5 in static pressure for ducting
up to 200 feet
Fits through a 36" man door
Input power required: 480V 87/138/196A 3PH
CAPS/150 kW
150 kW with (4) stages of heating capacity control
1×20 in supply air & 1×20 in return air
10 HP motor requires 480V 3PH 206A
MAKE MODEL HEAT OUTPUT POWER SOURCE FUEL TYPE DIMENSIONS (LWH)PRO RPP
CAT-CLASS
Val6 KBE5L 118,000/100,000 BTU 120V Diesel/Kerosene 29.2" x 28" x 36.5" 715-0435
Val6 DayStar 51,200 BTU 120V Diesel/Kerosene 22.8" x 12.2" x 23.4" 715-0408
VAL6/KBE5L VAL6/DAYSTAR
Radiant heat not affected by wind
Radiant heat penetrates evenly and directly onto surfaces
High and low output control
Radiant heat not affected by wind
Radiant heat penetrates evenly and directly onto surfaces
High and low output control
RADIANT + SPECIALITY
HEATING
46
HEA
TIN
G
Call 888-777-2700 for rates and reservations
FLAMELESS HEATERS
MAKE MODEL BTU CFM/SP FUEL TANK CONSUMPTION RUN TIMEDIMENSIONS (LWH)
WEIGHT CAT-CLASS
Wacker HIF690 457,667 3,778/5” 100 3.3 gal/hr 30 hrs 155" x 67" x 80" 3,230 lbs 715-1210
Wacker HIF1200 1,204,000 6,500/4” 206 8.6 gal/hr 23 hrs 158" x 70" x 93" 4,340 lbs 715-1240
MAC 550F 550,000 3,500/5” 125 2.6 gal/hr 40 hrs 176" x 72" x 82" 3,800 lbs 715-1210
MAC 750F 750,000 5,500/5” 165 3.55 gal/hr 46 hrs 192" x 72" x 85" 5,720 lbs 715-1220
MAC 950F 950,000 6,000/5” 165 5.4 gal/hr 30 hrs 192" x 72" x 85" 5,650 lbs 715-1230
WACKER/HIF 690
658,000 BTU output
CFM up to 3,778
Single axle trailer, 110% fluid containment
WACKER/HIF 1200
MAC/550F MAC/750F MAC/950F
1,200,000 BTU output
Ductable up to 200 ft
Single axle trailer, 110% fluid containment
440,000 BTU output
Adjustable CFM 1,400 - 3,500
Single axle trailer, 110% fluid containment
512,400 BTU output
Adjustable CFM 2,650 - 5,500
Dual axle trailer, 110% fluid containment
994,000 BTU output
Adjustable CFM 3,000 - 6,000
Dual axle trailer, 110% fluid containment
HEATING
HercRentals.com 47
HEATIN
G
MAKE MODEL BTU CFM/SP FUEL TANK CONSUMPTION RUN TIMEDIMENSIONS (LWH)
WEIGHT CAT-CLASS
Wacker HIF690 457,667 3,778/5” 100 3.3 gal/hr 30 hrs 155" x 67" x 80" 3,230 lbs 715-1210
Wacker HIF1200 1,204,000 6,500/4” 206 8.6 gal/hr 23 hrs 158" x 70" x 93" 4,340 lbs 715-1240
MAC 550F 550,000 3,500/5” 125 2.6 gal/hr 40 hrs 176" x 72" x 82" 3,800 lbs 715-1210
MAC 750F 750,000 5,500/5” 165 3.55 gal/hr 46 hrs 192" x 72" x 85" 5,720 lbs 715-1220
MAC 950F 950,000 6,000/5” 165 5.4 gal/hr 30 hrs 192" x 72" x 85" 5,650 lbs 715-1230
SELF-CONTAINED
MAKE MODEL TYPE BTU CFM/SP FUEL TANK CONSUMPTION RUN TIME DIMENSIONS (LWH) WEIGHT CAT-CLASS
Wacker HI 770XHD Diesel 770,000 4,000 / 4" 235 gal 5.5 gal/hr 40 hrs 187" x 94" x 88" 5,700 lbs 715-0810
MAC 800G Diesel 800,000 3,900 / 3" 175 gal 5.7 gal/hr 31 hrs 186" x 72" x 87" 4,620 lbs 715-0810
MAC 1.2G Diesel 1,200,000 6,500 / 3" 270 gal 8.6 gal/hr 31 hrs 252" x 96" x 103" 7,000 lbs 715-0820
Campo BLAZE CUBE 1200 Diesel 1,176,000 13,000 / 3" 237 gal 8.5 gal/hr 28 hrs 203” x 102” x 99” 7,000 lbs 715-0820
MAC/800G
CAMPO/BLAZE CUBE 1200 CHINOOK
800,000 BTU Indirect Oil Fired
On-board generator and ducting capabilities
Mounted on a single axle trailer
1,176,000 BTU Indirect oil fired
On-board generator and ducting capabilities
Mounted on a dual axle trailer
WACKER/HI 770XHD
MAC/1.2G
770,000 BTU Indirect Oil Fired
On-board generator and ducting capabilities
Mounted on a single axle trailer
1,200,000 BTU Indirect oil fired
On-board generator and ducting capabilities
Mounted on a dual axle trailer
HEATING
48
HEA
TIN
G
Call 888-777-2700 for rates and reservations
HEATING
HYDRONIC SURFACE HEATERS
MAKE MODEL TYPE BTUTHAWING CAPACITY
CURING CAPACITY
EFFICIENCYFUEL TANK
FUEL CONSUMPTION
RUN TIMEDIMENSIONS (LWH)
WEIGHT CAT-CLASS
THAWZALL TCH250 Diesel 234,000 6,000 sq ft 18,000 sq ft 82% 160 gal 1.75 gal/hr 72 hrs 170" x 84" x 96" 5,600 lbs 715-1010
Flex-Temp FUSION3000 Diesel 234,000 6,000 sq ft 18,000 sq ft 87% 170 gal 1.75 gal/hr 97 hrs 178.5" x 96" x 91" 8,295 lbs 715-1010
Wacker E3000 Diesel 385,000 6,000 sq ft 18,000 sq ft 83% 230 gal 2.75 gal/hr 140 hrs 181" x 91 "x 94" 7,190 lbs 715-1020
THAWZALL/TCH250 FLEX-TEMP/FUSION 3000 WACKER/E3000
280,000 BTU gross input
Return temperature display for monitoring
3 Days of run time
280,000 BTU gross input
Up to 3,000 ft of hose
150% fluid containment
385,000 BTU gross input
Up to 3,000 ft of hose
Up to 140 hours of run time
HEAT ON DEMANDScan code to view our expansive line of heating
solutions for any application and job site