8
1(800) 865-5931 www.alpinehomeair.com AC Heat Pump with Single Stage Gas Furnace and All Fuel Kit Control Wiring Heat Pump Standard Thermostat Standard Furnace Outdoor Heat Pump Thermostat 24 Volt+ Fan Only Operation Air Conditioning Common 1st Stage Backup Heat AC Reversing Valve Control Board Low Voltage Connection All Fuel Kit Thermostat Furnace Condenser 9 Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire. This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment installation guides to verify proper wiring. NOTE O O O O O O 1 2 3

Heat Pump Wiring Diagrams - Alpine Home Air

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Heat Pump Wiring Diagrams - Alpine Home Air

1(800) 865-5931www.alpinehomeair.com

AC Heat Pump with Single Stage Gas Furnace and All Fuel Kit Control Wiring

Heat Pump

Standard Thermostat

Standard Furnace

Outdoor Heat Pump Thermostat

24 Volt+

Fan Only Operation

Air Conditioning

Common

1st Stage Backup Heat

AC Reversing Valve

Control Board

Low Voltage Connection

All Fuel Kit

Thermostat

Furnace Condenser

9Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.

This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment

installation guides to verify proper wiring.

NOTE

O

O

O

O

O

O

1 2 3

Page 2: Heat Pump Wiring Diagrams - Alpine Home Air

1(800) 865-5931www.alpinehomeair.com

AC Heat Pump with Single Stage Gas Furnace and Honeywell VisionPro 8000 as All Fuel Kit Control Wiring

Heat Pump

Honeywell VisionPro 8000

Standard Furnace

24 Volt+

Fan Only Operation

Air Conditioning

1st Stage Gas Heat

AC Reversing Valve

Common

Outdoor Temp Sensor

Outdoor Temp Sensor

Control Board

Low Voltage Connection

10Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.

This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment

installation guides to verify proper wiring.

NOTES *Vision Pro 8000 works with wired or wireless outdoor temp sensor.

O

O

O

Y2

*To Outdoor Temp Sensor

AUX/E

AUX/E

Factory Jumper

Page 3: Heat Pump Wiring Diagrams - Alpine Home Air

Wire Size: 18 Gage

1(800) 865-5931www.alpinehomeair.com

AC Heat Pump with Standard Air Handler and No Electric Backup Heat

Standard Heat Pump Thermostat

Standard Air Handler

Heat Pump Condenser

24 Volt+

Fan Only Operation

Common

Air Conditioning-Heat Pump

Reversing Valve

1st Stage Heat (white)

2nd Stage Heat (brown)

Low Voltage Connection

11Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.

This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment

installation guides to verify proper wiring.

NOTE

O

O

O

Page 4: Heat Pump Wiring Diagrams - Alpine Home Air

Wire Size: 18 Gage

1(800) 865-5931www.alpinehomeair.com

AC Heat Pump with Standard Air Handler and Single Stage Electric Backup Heat

Standard Heat Pump Thermostat

Heat Pump Condenser

24 Volt+

Fan Only Operation

Common

Air Conditioning-Heat Pump

Reversing Valve

Electric Backup Heat

Low Voltage Connection

12Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.

This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment

installation guides to verify proper wiring.

NOTE

O

O

O

Standard Air Handler

AUX/E

Page 5: Heat Pump Wiring Diagrams - Alpine Home Air

Wire Size: 18 Gage

1(800) 865-5931www.alpinehomeair.com

AC Heat Pump with Standard Air Handler and Two Stage Electric Backup Heat

Standard Heat Pump Thermostat

Standard Air Handler

Heat Pump Condenser

24 Volt+

Fan Only Operation

Common

Air Conditioning-Heat Pump

Reversing Valve

1st Stage Heat Gas

Electric Backup Heat

Low Voltage Connection

13Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.

This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment

installation guides to verify proper wiring.

NOTE

O

O

O

Tied together

AUX/E

AUX/E

Page 6: Heat Pump Wiring Diagrams - Alpine Home Air

Wire Size: 18 Gage

1(800) 865-5931www.alpinehomeair.com

AC Heat Pump with Variable Speed Air Handler Without Electric Backup Heat Control Wiring

Standard Heat Pump Thermostat

Variable Speed Air HandlerHeat Pump Condenser

Low Voltage Connection

14Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.

This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment

installation guides to verify proper wiring.

NOTE

O

O

O

AUX/E

24 Volt+

Fan Only Operation

Common

Air Conditioning-Heat Pump

Reversing Valve

1st Stage Heat Gas

Electric Backup Heat

O

AUX/E

Y1 W1

Page 7: Heat Pump Wiring Diagrams - Alpine Home Air

Wire Size: 18 Gage

1(800) 865-5931www.alpinehomeair.com

AC Heat Pump with Variable Speed Air Handler and Single Stage Electric Backup Heat Control Wiring

15Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.

This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment

installation guides to verify proper wiring.

NOTE

24 Volt+

Fan Only Operation

Common

Air Conditioning-Heat Pump

Reversing Valve

1st Stage Heat Gas

Electric Backup Heat

O

AUX/E

Single Stage Heat Pump Thermostat

Variable Speed Air Handler

Heat Pump Condenser

Low Voltage ConnectionO

O

O

AUX/E

Tied together

Y1

Y2

W1

Page 8: Heat Pump Wiring Diagrams - Alpine Home Air

Wire Size: 18 Gage

1(800) 865-5931www.alpinehomeair.com

AC Heat Pump with Variable Speed Air Handler and Two Stage Electrical Backup Heat Control Wiring

16Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.

This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment

installation guides to verify proper wiring.

NOTE

24 Volt+

Fan Only Operation

Common

Air Conditioning-Heat Pump

Reversing Valve

1st Stage Heat Gas

Electric Backup Heat

O

AUX/E

Standard Heat Pump Thermostat

Variable Speed Air HandlerHeat Pump Condenser

Low Voltage ConnectionO

O

O

AUX/E

W1

Y1