8
07.2014 D5000ffe6 Subject to change HEAD Ebertstraße 30a 52134 Herzogenrath Tel.: +49 2407 577-0 Fax: +49 2407 577-99 eMail: [email protected] Web: www.head-acoustics.de Overview The ArtemiS SUITE is the integrated software solution from HEAD acoustics and unites tools for sound and vibration analysis, structured data management and reporting. The ArtemiS SUITE has a modular design, so users can customize their indi- vidual systems flexibly with the Basic Framework (ASM 00) and additional modules. The consistent operating philosophy and the various automation options ensure efficient working. The advantages become particularly apparent in the reporting area, where report templates can be populated automatically. The ArtemiS SUITE al- lows to produce new reports of the same type with new data from similar sources at the click of a button. On several pages diagrams, graphics, comments and other information from the documentation are combined automatically into a report. The impact measurement function is also an impressive example for the easy handling. The measurement parameters are determined automati- cally with a few test strikes, and the impact measurement is supervised by an automatic quality control with visual and acoustic feedback. More detailed information about the ArtemiS SUITE modules briefly presented here can be found in the respective datasheets. · Various statistical functions · Various filters (IIR filters, IIR filters with adjustable filter characteristics, parametric IIR filters, tracking filters etc.) · Playback with real-time filtering in the Mark Analyzer · Real-time filtering with the USB front end SQuadriga II · Easy and powerful reporting · CAN / OBD-2 / FlexRay decoder · Convenient editing of channel prop- erties of any number of files · Execution of channel-related calcu- lation methods · Impact measurement to examine the dynamic properties of mechani- cal components using SQuadriga II · Broadly based software structure allowing a seamless integration of customer-specific adaptations and future developments Features · Software for multi-channel sound and vibration analysis · Pool project with filter options, more than 130 analyses, statistical calcu- lations etc. · Documentation of data, e.g. for conveniently including them in gen- erated reports · Multi-level search functions includ- ing database and full text search · HEAD Navigator bar: easily drag and drop data into the Source Pool, report templates etc. · Recording software Data Acquisition Module (HEAD Recorder) for mobile use · Mark Analyzer for display, analysis and playback of time domain sig- nals · Playback with various configuration options · Flexible display options for analysis results, e.g. in the Data Viewer · Diagrams with various functionalities: · Easy activation of color fills be- tween curves (e.g. for the visual- ization of exceeded tolerances) · Quick marking of significant points · Convenient, direct editing of curve color and thickness with one click ArtemiS SUITE Overview Software solution for sound and vibra- tion analysis ArtemiS SUITE OVERVIEW DATENBLATT DATA SHEET

HEAD atenblatt stmesystems.net/wp-content/uploads/2017/04/d5000_artemis_suite_o… · ArtemiS suite Overview Software solution for sound and vibra-tion analysis ArtemiS suite overview

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HEAD atenblatt stmesystems.net/wp-content/uploads/2017/04/d5000_artemis_suite_o… · ArtemiS suite Overview Software solution for sound and vibra-tion analysis ArtemiS suite overview

07.2014 D5000ffe6 Subject to change

HEADEbertstraße 30a52134 HerzogenrathTel.: +49 2407 577-0Fax: +49 2407 577-99 eMail: [email protected]: www.head-acoustics.de

Overview

The ArtemiS suite is the integrated software solution from HEAD acoustics and unites tools for sound and vibration analysis, structured data management and reporting. The ArtemiS suite has a modular design, so users can customize their indi-vidual systems flexibly with the Basic Framework (ASM 00) and additional modules. The consistent operating philosophy and the various automation options ensure efficient working. The advantages become particularly apparent in the reporting area, where report templates can be populated automatically. The ArtemiS suite al-lows to produce new reports of the same type with new data from similar sources at the click of a button. On several pages diagrams, graphics, comments and other information from the documentation are combined automatically into a report. The impact measurement function is also an impressive example for the easy handling. The measurement parameters are determined automati-cally with a few test strikes, and the impact measurement is supervised by an automatic quality control with visual and acoustic feedback.More detailed information about the ArtemiS suite modules briefly presented here can be found in the respective datasheets.

· Various statistical functions · Various filters (IIR filters, IIR filters with adjustable filter characteristics, parametric IIR filters, tracking filters etc.)

· Playback with real-time filtering in the Mark Analyzer

· Real-time filtering with the USB front end SQuadriga II

· Easy and powerful reporting · CAN / OBD-2 / FlexRay decoder · Convenient editing of channel prop-erties of any number of files

· Execution of channel-related calcu-lation methods

· Impact measurement to examine the dynamic properties of mechani-cal components using SQuadriga II

· Broadly based software structure allowing a seamless integration of customer-specific adaptations and future developments

Features

· Software for multi-channel sound and vibration analysis

· Pool project with filter options, more than 130 analyses, statistical calcu-lations etc.

· Documentation of data, e.g. for conveniently including them in gen-erated reports

· Multi-level search functions includ-ing database and full text search

· HEAD Navigator bar: easily drag and drop data into the Source Pool, report templates etc.

· Recording software Data Acquisition Module (HEAD Recorder) for mobile use

· Mark Analyzer for display, analysis and playback of time domain sig-nals

· Playback with various configuration options

· Flexible display options for analysis results, e.g. in the Data Viewer

· Diagrams with various functionalities: · Easy activation of color fills be-tween curves (e.g. for the visual-ization of exceeded tolerances)

· Quick marking of significant points

· Convenient, direct editing of curve color and thickness with one click

ArtemiS suite Overview

Software solution for sound and vibra-tion analysis

ArtemiS suiteoverview

DatenblattData sheet

Page 2: HEAD atenblatt stmesystems.net/wp-content/uploads/2017/04/d5000_artemis_suite_o… · ArtemiS suite Overview Software solution for sound and vibra-tion analysis ArtemiS suite overview

07.2014 D5000ffe6 Subject to change

ArtemiS suite Modules ASMs

ASM 00 (Code 5000) ArtemiS suite Basic Framework Basis of the ArtemiS suite and connecting component of the various modules into a consistent

unit. Some central functions are already included in the Basic Framework.

ASM 01 (Code 5001) ArtemiS suite Basic Analysis Module Calculating of basic analysis functions using various preprocessing operations such as filtering,

sampling rate conversion, etc.ASM 02 (Code 5002) ArtemiS suite Basic Report Module Compilation of analysis results, texts, images etc. into a report according to your requirements

and presenting it in PowerPoint.ASM 03 (Code 5003) ArtemiS suite Data Base Module Indexing of data in a local MS SQL Server Express database, making them available for

structured and convenient search.ASM 04 (Code 5004) ArtemiS suite Data Acquisition Module HEAD Recorder Recorder software with modern, innovative concept, easy operation, and high convenience.ASM 11 (Code 5011) ArtemiS suite Adv. Playback Module Providing various real-time filters while a signal is being played back, and quick and convenient

filtering of time-domain signals in the Player or in the Mark Analyzer.ASM 12 (Code 5012) ArtemiS suite Psychoacoustics Module Using various functions and parameters for the description of subjective sound experiences.ASM 13 (Code 5013) ArtemiS suite Signature Analysis Module Analyzing of signals versus a range of different reference quantities (RPM, speed, pressure,

temperature, crank angle and other reference quantities) and calculating of order spectra.ASM 14 (Code 5014) ArtemiS suite Octave Analysis Module Using of recursive filters for the calculation of 1/n Octave analyses.ASM 15 (Code 5015) ArtemiS suite System Analysis Module Examinating of dynamic system characteristics.ASM 16 (Code 5016) ArtemiS suite Adv. Psychoacoustics Module Using of sophisticated, psychoacoustic analyses.ASM 17 (Code 5017) ArtemiS suite Adv. Analysis Module Using of sophisticated methods to analyze modulation spectra, tonal signal parts etc. ASM 18 (Code 5018) ArtemiS suite Online Analysis Module Impact measurements used to examine the dynamic properties of mechanical components with

the mobile front end SQuadriga II.ASM 19 (Code 5019) ArtemiS suite Adv. Filters Module Modifying of time domain signals with FIR filters and real-time filtering with the mobile front end

SQuadriga II.ASM 20 (Code 5020) ArtemiS suite Signal Editor Module See: ArtemiS Classic ATP 10 ASM 21 (Code 5021) ArtemiS suite Signal Generator Module

See: ArtemiS Classic ATP 10 ASM 22 (Code 5022) ArtemiS suite Adv. Report Module

See: ArtemiS Classic ATP 11 ASM 23 (Code 5023) ArtemiS suite Import & Export Module Using of several import and export options.ASM 24 (Code 5024) ArtemiS suite Data Preparation Module Extracting of CAN, OBD-2, and FlexRay signals and for efficient conditioning of multiple HDF or

DAT files.ASM 27 (Code 5027) ArtemiS suite Calculation Module Performing of channel-related calculation functions.

Page 3: HEAD atenblatt stmesystems.net/wp-content/uploads/2017/04/d5000_artemis_suite_o… · ArtemiS suite Overview Software solution for sound and vibra-tion analysis ArtemiS suite overview

07.2014 D5000ffe6 Subject to change

ASM 03 Basic Database Module (Code 5003) · SQL database · Inclusion of system documentation and user documentation in the search · Transfer of results lists to other program parts via copy & paste or drag & drop · Any number of user-defined navigation views for a custom sorting of the database · Requirements: ASM 00 Basic Frame work / Microsoft-SQL server 2008 R2 Express

ArtemiS suite

ASM 03

ASM 01 Basic Analysis Module (Code 5001) · Pool Project / Mark Editor · Mark Analyzer / Data Viewer / Diagram · Basic analysis functions and filter options · FFT vs. Time/(average)/(peak hold)/vs. RPM / Harmonic Distortion/vs. Frequency/vs. Time / Level vs. Time/vs. RPM / Octave/third octave analyses (from FFT) / Order Spectrum vs. Time/vs. RPM / Power Spectral Density vs. Time/(average)/(peak hold)/vs. RPM / Reverberation/vs. band / Specific Loud-ness (DIN 45631 and ANSI S3.4-2007) / Bypass

· Serial/parallel filter banks / IIR filters / Parametric IIR filters / Filters for frequency weighting / Equalization filters

· Sampling rate conversion of input signals · Unit Conversion / Vector Magnitude · Integrate / Differentiate / Delay · Several statistical functions / Export: HDF / HDFX · Requirements: Microsoft Office 2007 SP3, 2010 SP2 (x86), 2013 SP1 (x86) / MS PowerPoint (2007, 2010)

ArtemiS suite

ASM 01

ASM 04 Data Acquisition Module (Code 5004) HEAD Recorder · Easy configuration of front ends · Acquisition of several parameters (including pulses, temperature, video, CAN, OBD-2, FlexRay) · Online monitoring · Online generation of new channels or pulse signals · Several trigger functions · Programmable flow control · Automatic transfer of recordings into the Data Pool (ASM 01) · Requirements: ASM 00 Basic Frame work

ASM 02 Basic Report Module (Code 5002) · Individual layout templates with placeholders for diagrams, texts and images · Creation of reports from the calculation results of a Pool Project · Standardized reporting at the click of a button · Population of report templates via drag & drop · Easy editing of texts and graphics (vector graphics) in PowerPoint format · Requirements: ASM 00 Basic Frame work

ArtemiS suite

ASM 02

ASM 00 Basic Framework (Code 5000) · Player for playing back time domain signals / Playlists · Structured documentation / Documentation template editor · HEAD Navigation bar / HDF Info Dialog · Editor for creating tolerance schemes · Table Data Viewer / File Viewer · Frontend Reader · Import and export options: Wave, ASCII, ATFX, MP3, Excel (Excel import via CSV format)

ArtemiS suite

ASM 00

ArtemiS suite

ASM 04

Overview Modules

Page 4: HEAD atenblatt stmesystems.net/wp-content/uploads/2017/04/d5000_artemis_suite_o… · ArtemiS suite Overview Software solution for sound and vibra-tion analysis ArtemiS suite overview

07.2014 D5000ffe6 Subject to change

ASM 11 Advanced Playback Module (Code 5011) · Use of any number of customized filters: allpass, lowpass, highpass, bandstop, bandpass, paramet-ric bandpass, parametric lowpass and parametric highpass / tracking filter (order filter)

· Playback Spot for selecting distinct sound components · Requirements: ASM 00 Basic Frame work

ASM 12 Psychoacoustics Module (Code 5012) · Analysis of sound files possible under consideration of the specifics of the human hearing · Loudness vs. Time/Spec. Loudness vs. Time according to DIN 45631/ A1/ANSI S 3.4-2007 (FFT/FFT 3rd Octave)

· Articulation Index vs. Time · Fluctuation Strength vs. Time / Specific Fluc tuation Strength/vs. Time · Sharpness vs. Time according to DIN 45692/Aures/von Bismarck · Speech Interference Level vs. Time · Speech Intelligibility Index vs. Time · Specific Prominence/vs. Time · Requirements: ASM 00 Basic Frame work / ASM 01 Basic Analysis Module

Extensions: ASM 12 & ASM 13 · Articulation Index vs. RPM · Fluctuation Strength vs. RPM / Specific Fluctuation Strength vs. RPM · Loudness vs. RPM / Specific Loudness vs. RPM · Order Loudness vs. RPM/vs. Time / Specific Order Loudness vs. Time/vs. RPM · Sharpness vs. RPM · Order Roughness vs. RPM/vs. Time / Specific Order Roughness vs. Time/vs. RPM · Specific Prominence Ratio vs. RPM · Speech Intelligibility Index vs. RPM

Extensions ASM 14 & ASM 13 · 1/n Octave Spectrum (filter) vs. RPM

ASM 13 Signature Analysis Module (Code 5013) · Calculation methods: Variable DFT length / RPM-synchronous resampling / Time domain average · Reference Quantity (...) vs. Time · Order Spectrum (average)/Order Spectrum (peak hold) · 1/n Octave Spectrum (FFT) vs. RPM · Time Signal vs. Rotation · Gated Time Cuts / Gated Time Cuts (average) · Requirements: ASM 00 Basic Frame work / ASM 01 Basic Analysis Module · The Signature Analysis Module ASM 13 extends the functionality of other modules: ASM 12, ASM 14, ASM 15, ASM 16, ASM 17

ASM 14 Octave Analysis Module (Code 5014) · Use of recursive filters for: 1/nth Octave Spectrum Filter/(peak hold)/vs. Time · 6th / 9th / 12th / 24th / 48th / 96th octave analyses · 4th or 6th order selectable as filter properties · ANSI S1.11 (filter 6th order) · IEC 61260 (3rd octave filter 6th order) · DIN 45652 (3rd octave filter of 4th and 6th order · Requirements: ASM 00 Basic Frame work / ASM 01 Basic Analysis Module

ArtemiS suite

ASM 14

ArtemiS suite

ASM 13

ArtemiS suite

ASM 12

ArtemiS suite

ASM 11

Page 5: HEAD atenblatt stmesystems.net/wp-content/uploads/2017/04/d5000_artemis_suite_o… · ArtemiS suite Overview Software solution for sound and vibra-tion analysis ArtemiS suite overview

07.2014 D5000ffe6 Subject to change

Extensions ASM 15 & ASM 13 · Auto Correlation vs. RPM / Cross Correlation vs. RPM · Auto Spectrum vs. RPM / Cross Spectrum vs. RPM · Coherence vs. RPM · Impulse Response vs. RPM · Transfer Function vs. RPM

Extensions ASM 16 & ASM 13 · Impulsiveness (Hearing Model) vs. RPM / Specific Impulsiveness (Hearing Model) vs. RPM · Roughness (Hearing Model) vs. RPM / Specific Roughness (Hearing Model) vs. RPM · HSA vs. RPM

ASM 15 System Analysis Module (Code 5015) · System ana lysis/MIMO structural analysis · Analysis of the signal paths / Transfer Function/vs. Time · Impulse Response/vs. Time · Coherence/vs. Time / Coherent Spectrum / Multiple Coherence/Multiple Coherent Spectrum / Par-tial Coherence/Partial Coherent Spectrum

· Auto Spectrum/vs. Time / Auto Correlation vs. Time · Cross Spectrum/vs. Time / Auto Correlation vs. Band · Cross Correlation/vs. Time/vs. Band · Requirements: ASM 00 Basic Frame work / ASM 01 Basic Analysis Module

ASM 16 Advanced Psychoacoustics Module (Code 5016) · Evaluation of sound measurements with psychoacoustic parameters · Objectivation of subjective sound perception · Hearing Model Spectrum vs. Time · Impulsiveness (Hearing Model) vs. Time / Specific Impulsiveness (Hearing Model)/vs. Time · Roughness (Hearing Model) vs. Time / Specific Roughness (Hearing Model)/vs. Time · Relative Approach 2D/3D · HSA (average)/vs. Time · Requirements: ASM 00 Basic Frame work / ASM 01 Basic Analysis Module

ASM 17 Advanced Analysis Module (Code 5017) · Modulation Frequency vs. Time / Modulation Spectrum/vs. Band/vs. Time / Degree of Modulation vs. Time / Weighted Modulation Analysis

· Wavelet · Cepstrum/vs. Time · Kurtosis vs. Time · Level vs. Time (filtered)/vs. RPM (filtered) · GFT (Gated Fourier Transformation)/vs. Time · Spectral analyses with VFR (Variable Frequency Resolution) · VFR (average)/vs. Time · Tonality DIN 45681/vs. Time · Tone to Noise Ratio/vs. Time · Speech Transmission Index 2D · Envelope filter for calculating the envelope of a bandpass-filtered input signals · Requirements: ASM 00 Basic Frame work / ASM 01 Basic Analysis Module

Extensions ASM 17 & ASM 13 · Kurtosis vs. RPM · Cepstrum vs. RPM · Modulation Frequency vs. RPM / Modulation Spectrum vs. RPM / Degree of Modulation vs. RPM · Tone to Noise Ratio vs. RPM · Tonality DIN 45681 vs. RPM · VFR vs. RPM

ArtemiS suite

ASM 17

ArtemiS suite

ASM 16

ArtemiS suite

ASM 15

Page 6: HEAD atenblatt stmesystems.net/wp-content/uploads/2017/04/d5000_artemis_suite_o… · ArtemiS suite Overview Software solution for sound and vibra-tion analysis ArtemiS suite overview

07.2014 D5000ffe6 Subject to change

ASM 18 Online Analysis Module (Code 5018) · Guided step-by-step instructions · Choice of different coordinate systems · Automatic configuration of the desired measurement parameters · Automatic quality control for hammer strikes, repetition prompt in case of double strikes or if the level of the impact hammer signal is too high or too low

· Visual and acoustic feedback for test strikes and impact measurements · Checking of coherence between impact hammer and reference signal · Display of the results in the Data Viewer and as a report · Export of measurement results for further processing in the ME‘scopeVESTM analysis software from Vibrant Technology

· Requirements: ASM 00 Basic Frame work / SQuadriga II (Code 3320) or SQuadriga (Code 1369) / impact hammer / accelerometer

· Recommended: ASM 02 Basic Report Module / ASM 23 Import & Export Module / ME‘scopeVESTM (Code 4980ff) analysis software from Vibrant Technology

ASM 19 Advanced Filters Module (Code 5019) · FIR filters with filter characteristics adjustable in the frequency domain · Inverting of transfer functions · Display of the transfer functions · Smoothing functions · Input options: Transfer Function, Spectrum, Impulse Response

· Real-time filtering with the USB front end SQuadriga II · Pitch Shift · Requirements: ASM 00 Basic Frame work FIR filters: ASM 01 Basic Analysis Module Real-time filtering: Front end SQuadriga II (as of firmware 2.0) / binaural sensors (e. g. HMS IV, BHS II), standard microphones or accelerometers / closed headphone

ASM 23 Advanced Import & Export Module (Code 5023) · MATLAB · Ogg Vorbis · PAK · RPC · SDF · UFF · ME‘scope · Requirements: ASM 00 Basic Frame work · Recommended: ASM 15 System Analysis Module

ASM 24 Data Preparation Module (Code 5024) · CAN / OBD-2 / FlexRay decoder

· Quick import of manufacturer-specific DBC or XML databases (for CAN or FlexRay) · Preview for a visual check of decoding results

· Channel editor

· Convenient editing of channel properties of one or several HDF or DAT channels (batch process-ing)

· Various sorting options, e.g. by individual channel properties · Requirements: ASM 00 Basic Frame work / manufacturer-specific dbc respectively xml data base (for CAN and FlexRay) / for the export in specific foreign formats the Advanced Import & Export Module (ASM 23) is required

ArtemiS suite

ASM 24

ArtemiS suite

ASM 23

ArtemiS suite

ASM 19

ArtemiS suite

ASM 18

Page 7: HEAD atenblatt stmesystems.net/wp-content/uploads/2017/04/d5000_artemis_suite_o… · ArtemiS suite Overview Software solution for sound and vibra-tion analysis ArtemiS suite overview

07.2014 D5000ffe6 Subject to change

ASM 27 Calculation Module (Code 5027)

· Simultaneous, script-based processing of multiple channels · Execution of various mathematical functions (e.g. sin, log, sign) · Adjustable smoothing · Automated changing of channel measurement units · Use of predefined code segments · Compatible with ArtemiS Classic scripts · Requirements: ASM 00 Basic Frame work / ASM 01 Basic Analysis Module

ArtemiS suite

ASM 27

Page 8: HEAD atenblatt stmesystems.net/wp-content/uploads/2017/04/d5000_artemis_suite_o… · ArtemiS suite Overview Software solution for sound and vibra-tion analysis ArtemiS suite overview

07.2014 D5000ffe6 Subject to change

Microsoft, Windows and PowerPoint are registered trademarks of the Microsoft Corporation.

System Requirements

· Windows VISTA (32 bit and 64 bit: Business, Ultimate; languages: US / Western European), Service Pack 2 or:

· Windows 7 (32 bit and 64 bit: Professional, Enterprise, Ultimate; languages: US / Western European), Service Pack 1 or:

· Windows 8.1 (32 bit and 64 bit: Pro, Enterprise; languages: US / Western European) · ≥ Core2Duo processor 2 GHz · ≥ 2 GB RAM · Graphics card with DirectX9 and 256 MB or better · .NET Framework 4.0 · DirectX 9 · HASP dongle driver · Display with SXGA resolution (1280 x 1024) or better

In order to install software and drivers from HEAD acoustics, administrator rights are required. To operate the software, only standard user rights are needed.