2
HC6 RANGE Voltages 120V - 690V Outputs from 800 - 1438 kVA (4 pole) FEATURES: Permanent Magnet Generator (PMG) provides an isolated power supply to the excitation control system MX321 (PMG) as standard with 0.5% Regulation and 3 phase sensing 2/3 pitch winding as standard, to avoid excessive neutral currents Single or two bearing construction with dynamically balanced rotor and sealed-for-life bearings Easy access for installation and maintenance Built to conform with all leading industrial and marine standards IP23 as standard product profile OPTIONS & ACCESSORIES: Temperature Indication RTD’s Winding Protection Thermistors Air Condensation Heaters Air Filters Quadrature Droop kit for Parallel Operation Power factor Controller Diode Failure Unit Excitation Loss Module Manual Voltage Regulator HC-6 7/11/02 12:23 pm Page 1

HC6 RANGE - Powertech Engines Inc -- Authorized Ford ...€¢ Easy access for installation and maintenance • Built to conform with all leading industrial and marine standards •

  • Upload
    vutram

  • View
    216

  • Download
    2

Embed Size (px)

Citation preview

Page 1: HC6 RANGE - Powertech Engines Inc -- Authorized Ford ...€¢ Easy access for installation and maintenance • Built to conform with all leading industrial and marine standards •

HC6 RANGEVoltages 120V - 690V

Outputs from 800 - 1438 kVA (4 pole)

F E A T U R E S :

• Permanent Magnet Generator (PMG) provides an isolated power supply to the

excitation control system

• MX321 (PMG) as standard with 0.5% Regulation and 3 phase sensing

• 2/3 pitch winding as standard, to avoid excessive neutral currents

• Single or two bearing construction with dynamically balanced rotor and

sealed-for-life bearings

• Easy access for installation and maintenance

• Built to conform with all leading industrial and marine standards

• IP23 as standard

product prof i le

O P T I O N S & A C C E S S O R I E S :• Temperature Indication RTD’s

• Winding Protection Thermistors

• Air Condensation Heaters

• Air Filters

• Quadrature Droop kit for Parallel Operation

• Power factor Controller

• Diode Failure Unit

• Excitation Loss Module

• Manual Voltage Regulator

HC-6 7/11/02 12:23 pm Page 1

Page 2: HC6 RANGE - Powertech Engines Inc -- Authorized Ford ...€¢ Easy access for installation and maintenance • Built to conform with all leading industrial and marine standards •

HC 6 RANGEproduct prof i le

T Y P I C A L A P P L I C AT I O N S :Combined Heat & PowerParallel OperationPeak ShavingBase Load PrimeStandbyRentalTelecommunicationMarine/Offshore

3 Phase Ratings for STAMFORD HC6 Generators

50Hz (1500 rpm)4 Pole

Rating/AmbientApplication/Temp

RiseVoltage

HCI 6G kVAkW

HCI 6H kVAkW

HCI 6J kVAkW

HCI 6K kVAkW

Base 40ºCContinuous

125ºC

Peak 40ºC

Standby 150ºC

Peak 27ºC

Standby 163ºC

Base 40ºCContinuous

125ºC

Peak 40ºC

Standby 150ºC

Peak 27ºC

Standby 163ºC

60Hz (1800 rpm)

800

640

910

728

1000

800

1110

888

810

648

940

752

1030

824

1130

904

800

640

910

728

1000

800

1110

888

820

656

960

768

1060

848

1180

944

830

664

980

784

1070

856

1190

952

820

656

960

768

1060

848

1180

944

850

680

1000

800

1100

880

1220

976

860

688

1010

808

1100

888

1230

984

850

680

1000

800

1100

880

1220

976

875

700

1025

820

1150

920

1275

1020

925

740

1063

850

1200

960

1338

1070

1000

800

1125

900

1300

1040

1438

1150

913

730

1088

870

1206

965

1350

1080

969

775

1125

900

1250

1000

1413

1130

1046

837

1188

950

1350

1080

1525

1220

950

760

1125

900

1250

1000

1400

1120

1000

800

1163

930

1300

1040

1463

1170

1088

870

1219

975

1400

1120

1575

1260

380 400 415 380 400 415 380 400 415 416 440 480 416 440 480 416 440 480

3 Phase Ratings for STAMFORD HC6 Generators

50Hz (1000 rpm)6 Pole

Rating/AmbientApplication/Temp

RiseVoltage

HCI 6G kVAkW

HCI 6H kVAkW

HCI 6J kVAkW

HCI 6K kVAkW

Base 40ºCContinuous

125ºC

Peak 40ºC

Standby 150ºC

Peak 27ºC

Standby 163ºC

Base 40ºCContinuous

125ºC

Peak 40ºC

Standby 150ºC

Peak 27ºC

Standby 163ºC

60Hz (1200 rpm)

280

224

380

304

450

360

570

456

280

224

380

304

450

360

570

456

280

224

380

304

450

360

570

456

291

233

395

316

468

374

593

474

291

233

395

316

468

374

593

474

291

233

395

316

468

374

593

474

300

240

407

326

482

386

610

488

300

240

407

326

482

386

610

488

300

240

407

326

482

386

610

488

331

265

450

360

531

425

675

540

350

280

475

380

563

450

713

570

350

280

475

380

563

450

713

570

344

275

468

374

552

442

702

562

364

291

494

395

586

469

742

594

364

291

494

395

586

469

742

594

354

283

482

386

586

454

722

578

375

300

508

406

602

482

763

610

375

300

508

406

602

482

763

610

380 400 415 380 400 415 380 400 415 416 440 480 416 440 480 416 440 480

NEWAGE International Limited PO Box 17 · Barnack Road · Stamford Lincolnshire · PE9 2NB · EnglandTel.: +44 (0) 17 80 48 40 00 · Fax: + 44 (0) 17 80 48 41 00 e-mail: [email protected] · internet: www.newage-avkseg.com

©Newage International 2002

Due t

o ou

r poli

cy o

f con

tinuo

us im

prov

emen

t, de

tails

in th

is lea

flet w

hich

were

corre

ct at

time

of p

rintin

g ma

yno

w be

due

for a

mend

ment

. Inf

orma

tion

includ

ed m

ust t

here

fore

not

be r

egar

ded

as b

inding

PM_H

C6 P

P GB

_11.

02_0

2_GB

Standard Winding (311)

HC-6 7/11/02 12:23 pm Page 2