Hazardous Environments. Safe Solutions.Explosion-Proof Technology
Michael Shipley | Oil And Gas Business Development Manager
• Agenda Explosion-Proof Use CasesDesign And CertificationsHanwha Explosion-Proof Line UpInstallation Considerations
Notes:
This webinar is being recorded and will be available for replaying. The presentation materials will also be available in PDF format.
Please visit hanwhasecurity.com > training > webinars to view recorded webinars & sign up for future webinars.
We will take Q&A time permitting. In case there is not time to get to all of the questions, we will reply to you individually afterwards.
Please use the Chat or Q&A section.
All participants have been put in to listen only mode.
Do Not Cause ExplosionsExplosion-Proof Cameras
Do Not Survive Explosions
Explosion-Proof Use Cases
Oil and Gas Use CasesRefineries and Storage
Chemical PlantsLNG Plants
Not Generally SecurityProcess and Safety Monitoring
Oil and Gas Use Cases
C t act o
PipelinesPlatforms
Drilling and Storage Ships
Production and Safety Monitoring
Non-O&G Use CasesTHC Extraction
MiningGrain Elevators
Water/Wastewater
Safety Monitoring
Ethanol THC ExtractionHazard Rated
Design and Certifications
ⓒ 2019 Hanwha Techwin Co.,Ltd. All rights reserved.
Design Factors
Anodized Aluminum vs Stainless Steel Both generally accepted Aluminum lighter weight easier install Aluminum less costly Depending on location SS requires extra
safety requirements due to weight
PTZ Dome vs Traditional PT Dome lighter, easy mount options Look out and down applications Traditional PT look up applications Dome cannot be in Ketone or Ester
Atmospheres Dome -20C, optionally traditional PT to -60C
Explosion-Proof Notes Housings are NOT pressurized * Housings are not designed, tested or certified for above
atmospheric pressures, not suitable for very high pressure locations
Design is to contain with in the housing fire or sparks Cable entry points are sealed when the properly installed gland
and cable are used, design is to cut the flame path and must equal the certification level of the camera housing while all must match the hazardous area requirements.
ⓒ 2020 Hanwha Techwin Co.,Ltd. All rights reserved.
ULHazardous
Certification Preferred North America Certification cUL for CanadaOther Certifications accept UL testingExpensive, Long Process Based Primarily on Electrical Properties Flame/Spark ContainmentFollows NEC 500
Class I Gases and LiquidsClass II DustClass III Fibers Flying
Division 1 Continuously Present or Likely Present in Normal OperationDivision 2 Abnormally Present Short Duration
ⓒ 2020 Hanwha Techwin Co.,Ltd. All rights reserved.
FMHazardous
Certification Certified by DesignAccepted in US and InternationallyFactory Mutual is an Insurance CompanyDoes In-House TestingFast Test Approval Process Certifies for all others except ULFollows NEC 500 and or NEC 505 Depending on Product and Testing Request FM will provide Class
and Divisions or Class and Zones
ⓒ 2020 Hanwha Techwin Co.,Ltd. All rights reserved.
ATEXHazardous Certification
Primarily overseas Self Certifying Does no testing3rd Party Testing AcceptedFollows both NEC 500 and 505
IECExHazardous Certification EU Standard Accepted in US by exception and owner Does no testing3rd Party Testing Accepted from Approved Certification Bodies (UL, FM, Others)Follows NEC 505
Hanwha Explosion-Proof Line Up
ⓒ 2020 Hanwha Techwin Co.,Ltd. All rights reserved.
Fixed EPC Spectrum TNO Series
• Options include XNB-8000, XNB-6000, & XNZ-L6320 32x Zoom Box
• 5MP and 2MP cameras• Various Vari-focal Lens• Camera lens can be accessed without breaking seal• PoE only or PoE and 24v AC for heater• No wiper required due to special coating on glass• Light Weight• Temperature spec -40⁰C with heater• Assembled in Houston• 6 week lead time
Main Features:
ⓒ 2020 Hanwha Techwin Co.,Ltd. All rights reserved.
PTZ EPC Spectrum TNP Series
• Uses XNP-6320 2MP w/32x optical • Full suite analytics• PoE+ only• 38lbs without mounting• -20⁰C low temperature rating• Assembled in Houston• 6 week lead time
Main Features:
TNP-X6322EPT3-Z
ⓒ 2020 Hanwha Techwin Co.,Ltd. All rights reserved.
PTZ EPC Spectrum XNP Series
• Uses QNP-6230 2MP 23X Optical Zoom• PoE only• Economy model, no analytics• 38lbs without mounting• -20⁰C low temperature rating• Assembled in Houston• 6 week lead time
Main Features:
TNP-Q6232EPT3-Z
ⓒ 2020 Hanwha Techwin Co.,Ltd. All rights reserved.
Stainless Spectrum Mounting Accessories
Main Features:• HT-F1XX-WM, Fixed Wall Mount• HT-SF-FP, Fixed Fall Protection Kit• HT-SPMA-SD, Fixed/Dome Pole Mount Adaptor• HT-SD-VM, Fixed/Dome Vibration Reducing Plate• HT-SD-CM, Dome Corner Mount• HT-SD-WM, Dome Wall Mount• HT-SD-FP, Dome Fall Protection Kit
HT-F1XX-WM
HT-SD-VM
HT-SD-CM
HT-SF-FP
HT-SD-FP
HT-SPMA-SD
HT-SD-WM
ⓒ 2020 Hanwha Techwin Co.,Ltd. All rights reserved.
Fixed and PTZ Eaton Stainless Steel EPC
• Oxalis series 316L Stainless• UL certified C1D1, C1Z1, ATEX and IECEx• Power Options 24v AC and 120v AC• Option Built-in single mode simplex fiber optic• Wiper Option• -60⁰C option with cUL
Ability to Look UpX Series 32x Zoom BoxAdvanced PTZ control not available117lbs approximate weight16-22 week lead timeUK COO
X Series 32x Zoom Box33lbs approximate weight16-22 week lead timeUK COO
Installation Considerations
Installation Spectrum Fixed Housing
Mounting Housing Housing Access Camera Connection
Installation Spectrum Dome Housing
Mounting Housing Housing Access Camera Connection
Installation Spectrum Cable Entry
UL Glands Armored UL Cable External Camera Connection