1
Harsh Environment PLCs (HE PLCs) built and tested for extreme temperatures and vibrations in stand alone and avionic grade modules -70°C Our HE PLCs up to the splitting ratio 1x32* (2x32) are based on Telcordia specifications and their extension into HE region was achieved by continuous improvements in our over a decade fine-tuned manufacturing processes as well as by implementation of new materials. Following configurations apply*: Definition of Harsh Environment PLCs: As there’s not as yet standard for harsh environment optical components we use a combination of two standards (Arinc for optical fibers, and RTCA for vibration) in order to define in a broader sense a base for build up of optical specifications for harsh environment PLCs. PLC Splitters 1xN, 2xN HE PLC development and configuration 1x2, 1x3, 1x4, 1x6, 1x12 1x16, 1x24, 1x32 * Higher splitting ratios available upon request In view of vibration: Vibration tested not only at room temperature (as per RTCA standard) but also at - 55˚C and +85˚C with minimum effect on IL fluctuation (less than 0,1dB over the course of the test). Vibration testing based on RTCA - Not only at room temperature but also at -55˚C and 85˚C : - 5 to 14Hz peak to peak at 2.54mm (app from 0 to 1g) - 14 to 24Hz at decreasing amplitude (keeping it at 1g) - 24 to 112Hz peak to peak at 0.91mm (transition from 1g to 20g) - 112 to 2000Hz at decreasing amplitude (keeping at 20g) Typical Results of Vibration PLC +155°C IL variation (dB) acceleleration [g] 0,2 0,1 0,0 -0,1 -0,2 25 20 15 10 5 0 less than 0,05dB time [min] 0 5 10 15 44x4x4 53x7x4 nickel plated brass nickel plated brass HE PLC tested within RM modules Customer solutions RM for passive optical networks on the aircraft x axes y axes z axes Draka´s high temperature acrylate fiber (9/125BBXS) 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 -0,8 -0,6 -0,4 -0,2 0 0,2 0,4 0,6 0,8 -80 -50 -20 10 40 70 100 130 160 Time [h:min:sec] IL fluctuation [dB] Temperature [°C] 155°C -70°C Temperature cycling PLC 1x32 @ 1550 nm Optical specification 1xN: Housing dimension Housing material ® MTP - PLC module Straight type ® MPT Connector Angled type for HE composit monitoring HE PLC splitter In view of temperature: HE PLCs passed temperature cycling test, which is shown below so, that the IL increase for temperature extremes (-70˚C and 155˚C) did not exceed 1dB (=0,008dB/˚C). Typically, this value is around 0,5dB (= 0,004dB/˚C). Survived 100x cycles of temperature shocks between -70˚C and 155˚C. Survived more than 2000 hours of damp/heat (85%RH/85˚C) test. This long term test is still running and 5000 hours mark is quickly approaching. Vibration tested HE PLCs within avionic grade remote module at room temperature 0°C 0°C +155°C -70°C For More Information contact us at +420 493 765 111 or [email protected] SQS Vláknová optika a.s., Komenského 304, 509 01 Nová Paka, Czech Republic www.sqs-fiberoptics.com

Harsh Environment PLCs (HE PLCs) - SQS Fiber Opticswe use a combination of two standards (Arinc for optical fibers, and RTCA for vibration) in order to define in a broader sense a

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Harsh Environment PLCs (HE PLCs) - SQS Fiber Opticswe use a combination of two standards (Arinc for optical fibers, and RTCA for vibration) in order to define in a broader sense a

Harsh Environment PLCs (HE PLCs)built and tested for extreme temperatures and vibrations in stand alone and avionic grade modules

-70°C

Our HE PLCs up to the splitting ratio 1x32* (2x32) are based on Telcordia specifications and their extension into HE region was achieved by continuous improvements in our over a decade fine-tuned manufacturing processes as well as by implementation of new materials. Following configurations apply*:

Definition of Harsh Environment PLCs:

As there’s not as yet standard for harsh environment optical components we use a combination of two standards (Arinc for optical fibers, and RTCA for vibration) in order to define in a broader sense a base for build up of optical specifications for harsh environment PLCs.

PLC Splitters 1xN, 2xN

HE PLC development and configuration

1x2, 1x3, 1x4, 1x6, 1x12

1x16, 1x24, 1x32

* Higher splitting ratios available upon request

In view of vibration:

Vibration tested not only at room temperature (as per RTCA standard) but also at - 55˚C and +85˚C with minimum effect on IL fluctuation (less than 0,1dB over the course of the test).

Vibration testing based on RTCA

- Not only at room temperature but also at -55˚C and 85˚C : - 5 to 14Hz peak to peak at 2.54mm (app from 0 to 1g) - 14 to 24Hz at decreasing amplitude (keeping it at 1g) - 24 to 112Hz peak to peak at 0.91mm (transition from 1g to 20g) - 112 to 2000Hz at decreasing amplitude (keeping at 20g)

Typical Results of Vibration PLC

+155°C

IL v

ari

ati

on

(d

B)

ac

ce

lele

rati

on

[g

]

0,2

0,1

0,0

-0,1

-0,2

25

20

15

10

5

0

less than0,05dB

time [min]

0 5 10 15

44x4x4

53x7x4

nickel plated brass

nickel plated brass

HE PLC tested within RM modules

Customer solutionsRM for passive optical networks on the aircraft

x axes y axes z axes

Draka´s high temperature acrylate fiber (9/125BBXS)

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7-0,8

-0,6

-0,4

-0,2

0

0,2

0,4

0,6

0,8

-80

-50

-20

10

40

70

100

130

160

Time [h:min:sec]

IL f

luct

ua

tion

[d

B]

Te

mp

era

ture

[°C

]

155°C

-70°C

Temperature cycling PLC 1x32 @ 1550 nm

Optical specification 1xN: Housing dimension Housing material

®MTP - PLC module

Straight type

®MPT Connector

Angled type

for HE composit monitoring HE PLC splitter

In view of temperature:

HE PLCs passed temperature cycling test, which is shown below so, that the IL increase for temperature extremes (-70˚C and 155˚C) did not exceed 1dB (=0,008dB/˚C). Typically, this value is around 0,5dB (= 0,004dB/˚C).

Survived 100x cycles of temperature shocks between -70˚C and 155˚C.

Survived more than 2000 hours of damp/heat (85%RH/85˚C) test.This long term test is still running and 5000 hours mark is quickly approaching. Vibration tested HE PLCs within avionic grade remote module at room

temperature

0°C0°C

+155°C

-70°C