5
1. DO NOT SCALE 2. ALL PROPOSED WORKS SHOWN GREEN AND TEXT BOXED 3. SITE DESIGN CONFORMS TO EEL / MBNL DOCUMENT: STANDARD ICNIRP DESIGN RD10102 / GSDD008 Ver 8.0 E451170 N198297 1 A FIRST ISSUE MB 04.12.2017 HD102-21980 A 93283 - - VWH101 RADLEY ROAD SW GRASS VERGE ON RADLEY RD RADLEY ROAD ABINGDON 0X14 3SL PLANNING MB 29.11.2017 WP 04.12.2017 N SITE LOCATION SITE LOCATION PLAN SCALE 1:50000 CROWN COPYRIGHT RESERVED. MAPS REPRODUCED WITH THE PERMISSION OF THE CONTROLLER OF HM's STATIONERY OFFICE DIGITAL MAPPING SOLUTIONS FROM ORDNANCE SURVEY CROWN COPYRIGHT 2017 ALL RIGHTS RESERVED LICENCE NUMBER 100036966 DRAWN CHECKED ALL DIMENSIONS IN mm UNLESS OTHERWISE STATED. THIS DRAWING TO BE READ IN CONJUNCTION WITH OTHER RELEVANT DRAWINGS. REV BY DESCRIPTION OF REVISION DATE EE TRIDENT PLACE MOSQUITO WAY HATFIELD HERTFORDSHIRE AL10 9BW DRG No NOTES: REV SCALE: AS SHOWN WHEN PRINTED AT A3 THIRD PARTY REF OUK CELL ID SITE ADDRESS SITE NAME PURPOSE OF ISSUE DRAWING TITLE Design & Build Harlequin COLOUR CHART (REPRESENTS PROPOSED WORK AND NOT THE ACTUAL COLOUR OF THE EQUIPMENT-REFER TO SHEETS 500/501 FOR ICNIRP SPECIFIC KEY) H3G CELL ID MBNL CELL ID EE CELL ID N.G.R OPTION NUMBER 100 SITE LOCATION MAPS PHOTOGRAPH PROPOSED SITE/EQUIPMENT LOCATION 500 0 1000 1500 2000 2500m LINEAR SCALE 1:50000 Appendix 1

Harlequin - democratic.whitehorsedc.gov.ukdemocratic.whitehorsedc.gov.uk/documents/s43756/Appendices.pdf · proposed huawei 3900a cabinet (side by side) installed in ground root proposed

  • Upload
    doantu

  • View
    223

  • Download
    0

Embed Size (px)

Citation preview

1. DO NOT SCALE

2. ALL PROPOSED WORKS SHOWN GREEN AND TEXT BOXED

3. SITE DESIGN CONFORMS TO EEL / MBNL DOCUMENT:

STANDARD ICNIRP DESIGN RD10102 / GSDD008 Ver 8.0

E451170 N198297

1

A FIRST ISSUEMB 04.12.2017

HD102-21980 A

93283 - - VWH101

RADLEY ROAD SW

GRASS VERGE ON RADLEY RD

RADLEY ROAD

ABINGDON

0X14 3SL

PLANNING

MB 29.11.2017 WP 04.12.2017

N

SITE LOCATION

SITE LOCATION PLAN

SCALE 1:50000

CROWN COPYRIGHT RESERVED. MAPS REPRODUCED WITH THE PERMISSION

OF THE CONTROLLER OF HM's STATIONERY OFFICE

DIGITAL MAPPING SOLUTIONS FROM ORDNANCE SURVEY

© CROWN COPYRIGHT 2017

ALL RIGHTS RESERVED LICENCE NUMBER 100036966

DRAWN CHECKED

ALL DIMENSIONS IN mm UNLESS OTHERWISE STATED.

THIS DRAWING TO BE READ IN CONJUNCTION WITH

OTHER RELEVANT DRAWINGS.

REV BYDESCRIPTION OF REVISION DATE

EE

TRIDENT PLACE

MOSQUITO WAY

HATFIELD

HERTFORDSHIRE

AL10 9BW

DRG No

NOTES:

REV

SCALE:

AS SHOWN

WHEN

PRINTED AT A3

THIRD PARTY REF

OUK CELL ID

SITE ADDRESS

SITE NAME

PURPOSE OF ISSUE

DRAWING TITLE

Design & Build

Harlequin

COLOUR CHART

(REPRESENTS PROPOSED WORK AND NOT THE ACTUAL

COLOUR OF THE EQUIPMENT-REFER TO SHEETS 500/501 FOR ICNIRP SPECIFIC KEY)

H3G CELL ID MBNL CELL IDEE CELL ID

N.G.R

OPTION NUMBER

100

SITE LOCATION MAPS

PHOTOGRAPH

PROPOSED SITE/EQUIPMENT LOCATION

5000 1000 1500 2000 2500m

LINEAR SCALE 1:50000

Appendix 1

A FIRST ISSUEMB 04.12.2017

HD102-21980 A

93283 - - VWH101

RADLEY ROAD SW

GRASS VERGE ON RADLEY RD

RADLEY ROAD

ABINGDON

0X14 3SL

PLANNING

MB 29.11.2017 WP 04.12.2017

1. DO NOT SCALE

2. ALL PROPOSED WORKS SHOWN GREEN AND TEXT BOXED

3. SITE DESIGN CONFORMS TO EEL / MBNL DOCUMENT:

STANDARD ICNIRP DESIGN RD10102 / GSDD008 Ver 8.0

E451170 N198297

1

101

SITE ACCESS PLAN

DRAWN CHECKED

ALL DIMENSIONS IN mm UNLESS OTHERWISE STATED.

THIS DRAWING TO BE READ IN CONJUNCTION WITH

OTHER RELEVANT DRAWINGS.

REV BYDESCRIPTION OF REVISION DATE

EE

TRIDENT PLACE

MOSQUITO WAY

HATFIELD

HERTFORDSHIRE

AL10 9BW

DRG No

NOTES:

REV

SCALE:

AS SHOWN

WHEN

PRINTED AT A3

THIRD PARTY REF

OUK CELL ID

SITE ADDRESS

SITE NAME

PURPOSE OF ISSUE

DRAWING TITLE

Design & Build

Harlequin

COLOUR CHART

(REPRESENTS PROPOSED WORK AND NOT THE ACTUAL

COLOUR OF THE EQUIPMENT-REFER TO SHEETS 500/501 FOR ICNIRP SPECIFIC KEY)

H3G CELL ID MBNL CELL IDEE CELL ID

N.G.R

OPTION NUMBER

N

SITE LOCATION

SITE ACCESS PLAN

SCALE 1:1250

CROWN COPYRIGHT RESERVED. MAPS REPRODUCED WITH THE PERMISSION

OF THE CONTROLLER OF HM's STATIONERY OFFICE

DIGITAL MAPPING SOLUTIONS FROM ORDNANCE SURVEY

© CROWN COPYRIGHT 2017

ALL RIGHTS RESERVED LICENCE NUMBER 100036966

ROUTE FROM PUBLIC HIGHWAY

4511

00

12.50 25 37.5 50 62.5m

LINEAR SCALE 1:1250

198200

4512

00

198300

A FIRST ISSUEMB 04.12.2017

HD102-21980 A

93283 - - VWH101

RADLEY ROAD SW

GRASS VERGE ON RADLEY RD

RADLEY ROAD

ABINGDON

0X14 3SL

PLANNING

MB 29.11.2017 WP 04.12.2017

1. DO NOT SCALE

2. ALL PROPOSED WORKS SHOWN GREEN AND TEXT BOXED

3. SITE DESIGN CONFORMS TO EEL / MBNL DOCUMENT:

STANDARD ICNIRP DESIGN RD10102 / GSDD008 Ver 8.0

E451170 N198297

1

200

PROPOSED SITE PLAN

N

3

°

DRAWN CHECKED

ALL DIMENSIONS IN mm UNLESS OTHERWISE STATED.

THIS DRAWING TO BE READ IN CONJUNCTION WITH

OTHER RELEVANT DRAWINGS.

REV BYDESCRIPTION OF REVISION DATE

EE

TRIDENT PLACE

MOSQUITO WAY

HATFIELD

HERTFORDSHIRE

AL10 9BW

DRG No

NOTES:

REV

SCALE:

AS SHOWN

WHEN

PRINTED AT A3

THIRD PARTY REF

OUK CELL ID

SITE ADDRESS

SITE NAME

PURPOSE OF ISSUE

DRAWING TITLE

Design & Build

Harlequin

COLOUR CHART

(REPRESENTS PROPOSED WORK AND NOT THE ACTUAL

COLOUR OF THE EQUIPMENT-REFER TO SHEETS 500/501 FOR ICNIRP SPECIFIC KEY)

H3G CELL ID MBNL CELL IDEE CELL ID

N.G.R

OPTION NUMBER

PROPOSED SITE PLAN

SCALE 1:100

ELEVATION

PROPOSED FREDO CABINET TO BE

INSTALLED IN GROUND ROOT ON

PROPOSED CONCRETE FOUNDATION

PROPOSED HUAWEI 3900A CABINET (SIDE BY SIDE)

INSTALLED IN GROUND ROOT PROPOSED

CONCRETE FOUNDATION

GROUND LEVEL

0.0m DATUM

PROPOSED LINK AC CABINET TO BE

INSTALLED IN GROUND ROOT ON

PROPOSED CONCRETE FOUNDATION

EXISTING BT JUNCTION BOX

RADLEY ROAD

(30mph)

PROPOSED 15.0m HIGH ALPHA 8 TELEGRAPH

STRUCTURE ON NEW D9 ROOT FOUNDATION

EXISTING 8m HIGH

LAMP POST

EXISTING KERB LINE

PARKING

AREA

EXISTING

TREE

14m HIGH

APPROX

EXISTING

TREE

9.5m HIGH

APPROX

EXISTING

TREE

10m HIGH

APPROX

EXISTING

TREE

7m HIGH

APPROX

EXISTING TREE

4.5m HIGH

APPROX

A FIRST ISSUEMB 04.12.2017

HD102-21980 A

93283 - - VWH101

RADLEY ROAD SW

GRASS VERGE ON RADLEY RD

RADLEY ROAD

ABINGDON

0X14 3SL

PLANNING

MB 29.11.2017 WP 04.12.2017

1. DO NOT SCALE

2. ALL PROPOSED WORKS SHOWN GREEN AND TEXT BOXED

3. SITE DESIGN CONFORMS TO EEL / MBNL DOCUMENT:

STANDARD ICNIRP DESIGN RD10102 / GSDD008 Ver 8.0

E451170 N198297

1

300

PROPOSED SITE ELEVATION

DRAWN CHECKED

ALL DIMENSIONS IN mm UNLESS OTHERWISE STATED.

THIS DRAWING TO BE READ IN CONJUNCTION WITH

OTHER RELEVANT DRAWINGS.

REV BYDESCRIPTION OF REVISION DATE

EE

TRIDENT PLACE

MOSQUITO WAY

HATFIELD

HERTFORDSHIRE

AL10 9BW

DRG No

NOTES:

REV

SCALE:

AS SHOWN

WHEN

PRINTED AT A3

THIRD PARTY REF

OUK CELL ID

SITE ADDRESS

SITE NAME

PURPOSE OF ISSUE

DRAWING TITLE

Design & Build

Harlequin

COLOUR CHART

(REPRESENTS PROPOSED WORK AND NOT THE ACTUAL

COLOUR OF THE EQUIPMENT-REFER TO SHEETS 500/501 FOR ICNIRP SPECIFIC KEY)

H3G CELL ID MBNL CELL IDEE CELL ID

N.G.R

OPTION NUMBER

PROPOSED NORTH ELEVATION

SCALE 1:100

GROUND LEVEL

0.0m

TOWER DETAILS:

CODE:

CUSTOM:

CABINET DETAILS:

HUAWEI 3900A CABINET (SIDE BY SIDE)

ANTENNA DETAILS:

TOWER SUPPLIER:

COLOUR REF:HEIGHT:

15.0m-

N

TOWER DESCRIPTION:

CUSTOM COMMENT:

NA

COLOUR REF:

COLOUR REF:

STANDARD

FIR GREEN (RAL6009)FREDO CABINET

LINK AC

ALPHA 8 STREETPOLEBLACK BROWN (RAL8022)

HUTCHINSON ENG.

ALPHA 3363 TRISECTOR ANTENNA & 2No. DISHES

FIR GREEN (RAL6009)

FIR GREEN (RAL6009)

PROPOSED ALPHA 3363 TRISECTOR

ANTENNA WITHIN GRP SHROUD

PROPOSED 2 No. 300mmØ DISHES EGN TBC

TOP OF PROPOSED POLE

15.0m AGL

TOP OF PROPOSED ANTENNAS

15.0m AGL

C/L OF DISHES

11.9m AGL

EXISTING 8m HIGH LAMP POST

EXISTING BT JUNCTION BOX

PROPOSED FREDO CABINET TO BE

INSTALLED IN GROUND ROOT ON

PROPOSED CONCRETE FOUNDATION

PROPOSED HUAWEI 3900A CABINET (SIDE

BY SIDE) INSTALLED IN GROUND ROOT

PROPOSED CONCRETE FOUNDATION

PROPOSED LINK AC CABINET TO BE

INSTALLED IN GROUND ROOT ON

PROPOSED CONCRETE FOUNDATION

PROPOSED 15.0m HIGH ALPHA 8 TELEGRAPH

STRUCTURE ON NEW D9 ROOT FOUNDATION

C/L OF PROPOSED ANTENNAS

13.6m AGL

A FIRST ISSUEMB 04.12.2017

HD102-21980 A

93283 - - VWH101

RADLEY ROAD SW

GRASS VERGE ON RADLEY RD

RADLEY ROAD

ABINGDON

0X14 3SL

PLANNING

MB 29.11.2017 WP 04.12.2017

A1

60°

N

HEADFRAME PLAN @ 15.0m AGL

SCALE 1:25

ANTENNA LINE KEY

SECTOR ID ANTENNA TYPE

OPERATING

FREQUENCY

MHA NAME

RET

CABLE

LOCATION

RET

NAME

ANT

JUMPER

LENGTH (m)

AND TYPE

MAIN

FEEDER

LENGTH (m)

AND TYPE

BTS TAIL

LENGTH (m)

AND TYPE

A1

800/1800/

2100

HUAWEI

3900A

-

1m

LCF12-50

16m

LCF78-50

2m

LCF12-50

ESTIMATED

TOTAL LOSS

(dB)

PROPOSED

PROPOSED EEL DISH KEY

COMMENTS

PROPOSED

DISH DIA.

300mm

AZIMUTH

(EGN)

TBC°

HEIGHT TO

CENTRE

(AGL)

11.9m

FUNCTION

LINK No.

TBC

A2

-

1m

LCF12-50

16m

LCF78-50

2m

LCF12-50

A3-

1m

LCF12-50

16m

LCF78-50

2m

LCF12-50

DISH

REF

D1

D2

ALPHA 3363

TRISECTOR

ANTENNA

PROPOSED

PROPOSED

ANTENNA

C/L (m)

AGL

13.6m

BEARING

(°)

60° EGN

180° EGN

300° EGN

MECHANICAL

TILT (°)

0

0

0

PORT

FREQUENCY

RANGE

790-2690

790-2690

790-2690

RFU/

RRU

RFU

RFU

RFU

ANTENNA TYPE AZIMUTH TILT

AND PORTS

ANTENNA PORT

ALLOCATION

MHA REF RET OVERALL SYSTEM LOSS

PROPOSED300mm TBC° TBC

REMOTE

RFU?

(Y/N)

N

N

790

960

1710

2690

1710

2690

1800/

2100

MHA

1800/

2600

MHA

2100

'EE'

UMTS

2100

'EE'

UMTS

ANTENNA SCHEMATIC

PROPOSED 6 PORT

ALPHA 3363

TRISECTOR

ANTENNA

EEL POWER REQUIREMENT - PROPOSED 21kVA SINGLE PHASE SUPPLY (DNO)

A2

180°

A3

300°

PROPOSED EEL EQUIPMENT SCHEDULE

ITEM TYPE COMMENTS

PROPOSED

SIZE (mm) (HxWxD)

LINK AC 1520x600x500IT-1

IT-2

IT-3

PROPOSED

HUAWEI

3900A

900x1200x480

NOTE: INFORMATION HELD ON INS TAKES PRECEDENCE OVER ALL KEYS AND SCHEDULES SHOWN

OTHER INFO.

-

PROPOSEDFREDO 1240x900x800 -

800/1800

'EE'

GSM/LTE

800/1800/

2100

800/1800/

2100

RADIO DESIGN

RD0433

1800/2100 DDLNA

RADIO DESIGN

RD0448-02

1800/2100 DDLNA

D1

D2

13.6m

13.6m

SIDE BY SIDE

ALPHA 3363

TRISECTOR

ANTENNA

ALPHA 3363

TRISECTOR

ANTENNA

11.9m

FUTURE

MHA

FEEDERS PRE

RIGGED FOR

FUTURE

DEPLOYMENT

FREDO

HUAWEI

3900A

FREDO

HUAWEI

3900A

FREDO

RADIO DESIGN

RD0433

1800/2100 DDLNA

RADIO DESIGN

RD0448-02

1800/2100 DDLNA

RADIO DESIGN

RD0433

1800/2100 DDLNA

RADIO DESIGN

RD0448-02

1800/2100 DDLNA

1. DO NOT SCALE

2. ALL PROPOSED WORKS SHOWN GREEN AND TEXT BOXED

3. SITE DESIGN CONFORMS TO EEL / MBNL DOCUMENT:

STANDARD ICNIRP DESIGN RD10102 / GSDD008 Ver 8.0

E451170 N198297

1

400

EQUIPMENT SCHEDULE

DRAWN CHECKED

ALL DIMENSIONS IN mm UNLESS OTHERWISE STATED.

THIS DRAWING TO BE READ IN CONJUNCTION WITH

OTHER RELEVANT DRAWINGS.

REV BYDESCRIPTION OF REVISION DATE

EE

TRIDENT PLACE

MOSQUITO WAY

HATFIELD

HERTFORDSHIRE

AL10 9BW

DRG No

NOTES:

REV

SCALE:

AS SHOWN

WHEN

PRINTED AT A3

THIRD PARTY REF

OUK CELL ID

SITE ADDRESS

SITE NAME

PURPOSE OF ISSUE

DRAWING TITLE

Design & Build

Harlequin

COLOUR CHART

(REPRESENTS PROPOSED WORK AND NOT THE ACTUAL

COLOUR OF THE EQUIPMENT-REFER TO SHEETS 500/501 FOR ICNIRP SPECIFIC KEY)

H3G CELL ID MBNL CELL IDEE CELL ID

N.G.R

OPTION NUMBER