36
agricultural catalog v.6 testing equipment for growers

Hanna Instruments Agricultural Products Catalog 2010

Embed Size (px)

DESCRIPTION

Hanna Instruments provide full support for the Agricultural Community. Hanna Ag Products include: pH Testers and Meters, Alkalinity, Handheld Colorimeter and Test Kit, Conductivity, TDS Testers and Meters, pH, EC, TDS, Temperature Multiparameter Meters, N, P, K Multiparameter Photometer and Lysimeter, Refractometers for Sugar (Brix) Measurement.

Citation preview

Page 1: Hanna Instruments Agricultural Products Catalog 2010

agriculturalcatalog v.6

testing equipment for growers

Page 2: Hanna Instruments Agricultural Products Catalog 2010

2

abou

t us

v.6agcat

4 pH Testers and Meters

6 Alkalinity Handheld Colorimeter and Test Kit

7 Conductivity/TDS Testers and Meters

10 pH/EC/TDS/Temperature Multiparameter Meters

12 N, P, K Multiparameter Photometer and Lysimeter

14 Refractometers for Sugar (Brix) Measurement

ISO 9001:2000CERTIFIED

These instruments are manufactured in our European state-of-the-art ISO 9001:2000 production facility and is CE compliant to EN 61326-1 and EN 61010-1 standards.

cont

ents

We Design, Manufacture, Supply andSupport All of Our Products. That’s 360° Value.HANNA believes in supplying the agricultural community with a simple method for testing the parameters that are essential to the proper growth of plants and vegetables. You will find that ourproducts are extremely easy to use, economical and will assist you in growing superior crops—assuring that the quality of your product is at its peak.

When you buy a HANNA product, you’re not only buying the best value for your money, but you’realso adding the benefit of HANNA’s unsurpassed customer service and post-sale technical support.

HANNA Instruments, USAHighland Industrial Park584 Park East Drive, Woonsocket, Rhode Island 02895

phone: (800) 426-6287fax: (401) [email protected]

contact

Page 3: Hanna Instruments Agricultural Products Catalog 2010

HANNA is the largest family-owned manufacturer of analytical instrumentation in the world. For over 30 years, HANNA has never failed to deliver fresh and innovative products to its customers.

3With Great Products, Come Great Results™ v.6agcat

15 Dissolved Oxygen

16 Relative Humidity

17 Lux (Light) Meter and Fertilizer Level Controller

18 Thermometer Tester, T-logger and Meter

19 Instruments for Sanitizing Irrigation Water (Cl2/ORP)

23 Continuous pH (Acid) Monitoring and Controlling

24 Fertigation for pH and EC Control

32 Cleaning, Storage and Calibration Solutions

34 User Guides

35 Limited Warranty and Return Information

Page 4: Hanna Instruments Agricultural Products Catalog 2010

4

pH

v.6agcat

pH

With a renewable cloth junction, the pHep®has an extended life over typical pH testers.Since a normal junction clogs with use overtime, a typical tester would normally have to bethrown away once the junction gets tooclogged. HI 98107’s junction is 2 cm long andwhen dirty can be pulled out to expose a freshsection. The pHep® effectively renews its life.

HI 98107 pHep®pH TESTER• Renewable Junction

• Easy 1 or 2 point manual calibration

• 700 hour battery life

SPECIFICATIONS HI 98107 (pHep®)Range 0.0 to 14.0 pH

Resolution 0.1 pH

Accuracy (@20°C/68°F) ±0.1 pH

Battery Type (4) 1.5V

ORDERING INFORMATIONHI 98107 (pHep®), is supplied with protective cap, calibration screwdriver, batteries and instructions.

HI 98103 Checker®pH TESTER• High accuracy with 0.01 pH resolution

• 2-point fast calibration

• Compatible with other screw type electrodes

• Ideal for testing pesticide stock solution

ORDERING INFORMATIONHI 98103 (Checker®) is supplied with screw-type pHelectrode

ELECTRODESHI 1270 pH electrode with screw-type connector

SPECIFICATIONS HI 98103 Checker®Range 0.00 to 14.00 pH

Resolution 0.01 pH

Accuracy (@20°C/68°F) ±0.2 pH

Battery Type (2) 1.5V

The Checker® supplies users with fast and accurate readings from 0 to 14 pH with a reso-lution of 0.01 pH. This compact tester featuresa large easy-to-read LCD and simple to perform2-point calibration.

Pounds of Lime to Raise the Soil pH

pH Value fromSoil Test

Amount of Lime to Add/1,000 sq. ft.

Below 5.0 100 lb. agricultural lime

5.0-6.0 50 lb. agricultural lime

Above 6.0 Do not use lime

Pounds of Sulfur to Lower the Soil pH per 1,000 sq. ft.

PresentpH Desired pH

8.0 1.8 2.4 3.3 4.2 4.8

7.5 1.2 2.1 2.7 3.6 4.2

7.0 .06 1.2 2.1 3.0 3.6

6.5 .06 1.5 2.4 2.7

lbs. to add 6.5 6.0 5.5 5.0 4.5

Increase Rate 1/2 for Clay Soil

ORDERING INFORMATIONHI 8424 is supplied with pH electrode, temperatureprobe, starter set of calibration and cleaning solutions, battery, protective case and instructions.

ELECTRODESHI 1332B ORP electrode, gel filled, PEI body, BNC connector with 1 m (3.3’) cable

HI 8424pH METER• ORP mode

• Automatic calibration

• BEPS

• Auto shut-off

• Probe condition verification using mV mode*

SPECIFICATIONS HI 8424

Range

pH -2.00 to 16.00 pH

mV ±699.9 mV; ±1999 mV

Temperature -20.0 to 120.0°C / -4.0 to 248.0°F

Resolution

pH 0.01

mV 0.1 mV; 1 mV

Temperature 0.1°C / 0.1°F

Accuracy(@20°C)

pH ±0.01

mV ±0.2 mV; ±1 mV

Temperature ±0.4°C / ±0.8°F

Battery Type 9V

NEUTRAL MORE BASIC/ALKALINEMORE ACID76543210 8 9 10 11 12 13 14

Soiless Media

Direct Soil

Growing medium pH guidelines for some common greenhouse plantsIron Inefficient Plants

pH 5.4 to 6.2General Group

pH 5.8 to 6.4Iron Efficient Plants

pH 6.0 to 6.6Bacopa Chrysanthemum Geranium (seed and zonal)

Calibrachoa Geranium (ivy) Marigold

Nemesia Impatiens New Guinea Impatiens

Pansy Poinsettia Lisianthus

Petunia

Snapdragon

Scaevoia

pH MeasurementspH is the measurement of hydrogen ion concentration (H+) in water or soil. A pH of 7 is considered neutral. A pH below 7 is considered more acidic and a pH above 7 is considered more basic or alkaline. Water pH is important for plant management because it affects the solubility offertilizers and the effectiveness of insecticides and fungicides.

Below is a pH scale that ranges from 0 – 14 pH. Most plants have an optimal pH between 5.8 and 6.4 pH in soil-less media. For direct soil applications, a typical pH range of 6.5 – 7.0 pH is more common.

* pH 7 = 0.0 mV pH 4 = 174.5 mV

Affects the solubility of mineralsespecially minor elements

Page 5: Hanna Instruments Agricultural Products Catalog 2010

5

pH

With Great Products, Come Great Results™ v.6agcat

HI 99121DIRECT SOIL pH MEASUREMENT KIT• Specialized soil electrode

• Waterproof

• Multi-level LCD display Displays current measurement along with current temperature. A quick-guide is also displayed to aid users in operation

• HOLD button The Hold button freezes readings on the display so you can manually record readings• University tested for accuracy

• Automatic Temperature Compensation

• Automatic 1 or 2 point calibration

• BEPS (Battery Error Prevention System) Alerts the user in the event that low battery power could adversely affect readings

• Battery % displayed on startup

• Easy to Clean The glass electrode is easy to clean and keep clean by design

With HI 99121 you can test both the pH of soil directly or after preparationof a diluted sample. The HI 1292D pH electrode has been specificallydesigned for direct soil measurement. It has a conical tip and canbe directly inserted in moist or soft soil. A soil preparation solution and ground auger is included for harder soils.

Ground auger

• pHep™4 reads 0.1 scale while pHep™5 reads 0.01

• Waterproof and floating

• Dual-level LCD

• Cloth, renewable junction

• BEPS (Battery Error Prevention System)

• Battery % display at startup

• Automatic shut-off

• Automatic Temperature Compensation

• Automatic calibration

• HOLD button to freeze readings on the display

• Replaceable pH Electrode The stainless steel round connector means there are no pins to bend or break.

• ºF and ºC measurement

• Exposed Temperature Sensor Provides fast response time and high accuracy in temperature compensated readings.

HI 98127 (pHep®4) & HI 98128 (pHep®5)pH/TEMPERATURE TESTERS

ORDERING INFORMATIONHI 98127 (pHep®4) and HI 98128(pHep®5) are supplied with pH electrode,electrode removal tool and batteries.

ACCESSORIESHI 73127 Spare electrodeHI 73128 Electrode removal tool

SPECIFICATIONS HI 98127 (pHep®4) HI 98128 (pHep®5)

RangepH -2.0 to 16.0 pH -2.00 to 16.00 pH

Temperature -5.0 to 60.0°C / 23.0 to 140.0°F

ResolutionpH 0.1 pH 0.01 pH

Temperature 0.1°C / 0.1°F

Accuracy(@20°C)

pH ±0.1 pH ±0.05 pH

Temperature ±0.5°C /±1°F

Battery Type (4) 1.5V with BEPS

• Protective Rubber Boot Our optional rubber boot helps to protect your meter

ORDERING INFORMATIONHI 99121 is supplied with pH electrode, soil auger, soilpreparation solution, starter set of calibration solutionsachets, 100 ml plastic beaker, batteries, hard carryingcase and instructions.

ELECTRODESHI 1292D Specialized soil pH electrode with DIN connector and 1 m (3.3’ cable)

ACCESSORIESHI 721319 Ground augerHI 710020 Orange protective rubber bootHI 710021 Blue protective rubber boot

SPECIFICATIONS HI 99121

RangepH -2.00 to 16.00 pH

Temp. -5.0 to 105.0°C; 23.0 to 221.0°F

ResolutionpH 0.01 pH

Temp. 0.1°C/0.1°F

Accuracy(@20°C)

pH ±0.02 pH

Temp. ±0.5°C (up to 60°C); ±1°C (outside);±1°F (up to 140°F); ±2°F (outside)

Battery Type (3) 1.5V AAA

See Page 34for more infoon testing soilusing a slurry

Page 6: Hanna Instruments Agricultural Products Catalog 2010

6

alka

linit

y

v.6agcat

SPECIFICATIONS HI 755 (Alkalinity)Range 0 to 250 ppm (mg/L)

Resolution 0.1 ppm (mg/L)

Accuracy ±10% of reading (0-75) and ±5% of reading (75-250)

Battery Type (1) 1.5V AAA

The HANNA HI 755 Checker®HC bridges the gapbetween simple chemical test kits and professionalinstrumentation. Chemical test kits are not very accurate and only give 5to 10 points resolution while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain.The HANNA HI 755 Checker®HC is accurate and affordable.

The HI 755 Checker®HC is extremely simple to use. First, zero the instrument with your water sample. Next, add the reagent. Last, Place thevial into the HI 755 Checker®HC, press the button and read the results. It’s that easy. See Page 34 for more information.

Accurate and AffordableAlkalinity Measurement

ORDERING INFORMATIONHI 755 Checker®HC is supplied with (2) sample cuvettes with caps, (6) powder reagentsfor iodine, (1) 1.5V AAA battery and instructions.

REAGENTS AND STANDARDSHI 755-25 Reagents for 25 tests (alkalinity)HI 755-11 Calibration standard, 0 and 100 ppm

ACCESSORIES

SPECIFICATIONS HI 3811 (Alkalinity (as CaCO3)Phenolphthalein and Total)

Range 0-100 mg/L (ppm)0-300 mg/L (ppm)

Smallest Increment 1 mg/L (ppm)3 mg/L (ppm)

Chemical Method Phenolphthalein/Bromphenol blue

Method Titration

ORDERING INFORMATIONHI 3811 is supplied with enough reagents for approximately 110 tests.

HI 755CHECKER HC™ ALKALINITYHANDHELD COLORIMETEREasier to use and more accurate than chemical test kits Colorimetric method Large, easy to read digits Auto shut-off

Small Size, Big Convenience The Checker®HC easily fits into the palm of your hand or pocket Use for quick and accurate on the spot analysis Single button operation: Zero and Measure Operated by a single AAA battery

AlkalinityAlkalinity is another measurement growers should be aware of. Alkalinity is the ability of a substance to resist a change in pH. Alkalinity is generally defined as the buffering capacity of a solution.It affects how much acid is needed to control pH. Alkalinity is meas-ured in mg/L of Calcium Carbonate (CaCO3). The higher the alkalinity of your water, the more resistant it will be to controllingthe pH. The lower the alkalinity, the higher the volatility in achievingthe optimal pH value.

Common Alkalinity Problems and SuggestionsProblem Suggestion

High Alkalinity > 150 ppm

High media pH iron deficiency Acidify, Use acidic type fertilizer

Ideal greenhouse alkalinity: 60-120 ppm

Low Alkalinity < 40 ppm

Low medium pH,Iron toxicity,

Ca and Mg deficiency

Use basic type fertilizer,add extra lime to media,

Use fertilizer with extra Ca and Mg

HI 731318 (4) Cuvette cleaning clothHI 731321 (4) Glass cuvettes

HI 731225 (4) Caps for cuvettesHI 93703-50 Cuvette cleaning solution, 230 mL

alk HI 3811ALKALINITYTEST KIT

A measurement of dissolvedCalcium Carbonate ( lime)

Page 7: Hanna Instruments Agricultural Products Catalog 2010

v.6agcat With Great Products, Come Great Results™

conductivity

7

ORDERING INFORMATIONHI 98300 (DiST®1), HI 98301 (DiST®1), HI 98302 (DiST®2), HI 98303 (DiST®3) and HI 98304(DiST®4) are supplied with protective cap, screwdriver, batteries and instructions.

SPECIFICATIONS HI 98300 / HI 98301 (DIST® 1)

HI 98302(DIST® 2)

HI 98303(DIST® 3)

HI 98304(DIST® 4)

Range 1999 mg/L (ppm) 10.00 g/L (ppt) 1999 μS/cm 19.99 mS/cm

Resolution 1 mg/L (ppm) 0.01 g/L (ppt) 1 μS/cm 0.01 mS/cm

Accuracy (@20°C/68°F) ±2% F.S. ±2% F.S. ±2% F.S. ±2% F.S.

Battery Type / Life (4) 1.5V / approx. 200 hours of continuous use

DiST®: HI 98300, HI 98301, HI 98302 HI 98303 & HI 98304EC AND TDS TESTERS• Simple 1 point calibration

• Graphite electrodes

• Automatic Temperature Compensation

HI 98331 SOIL TEST™DIRECT SOIL EC TESTER • Replaceable 122 mm (4.5”) Penetration probe

• Automatic temperature compensation

• Lightweight and portable

The HI 98331 Soil Test™ is a pocket tester specifically designed to directly measure soil conductivity and temperature in saturated soil. With a temperature sensorin the penetration probe, readings are automatically temperature compensated. Conductivity range can be calibrated at one point and is designed to be performedin a standardized solution.

Specifications HI 98331 Soil Test™

RangeEC 0.00 to 4.00 mS/cm (dS/m)

Temperature 0.0 to 50.0°C

ResolutionEC 0.01 mS/cm

Temperature 0.1°C

Accuracy(@20°C)

EC ±0.05 mS/cm (0.00 to 2.00 mS/cm), ±0.30 mS/cm (2.00 to 4.00 mS/cm)

Temperature ±1°C

Battery Type (4) 1.5V

ORDERING INFORMATIONHI 98331 (Soil Test™) is supplied with HI 73331 penetration con-ductivity probe, batteries, calibration screwdriver and instructions.

PROBESHI 73331 Direct soil conductivity probe

ACCESSORIESHI 731326 Calibration screwdrivers (20)

HI 98311 DiST® 5 & HI 98312 DiST® 6EC/TDS/TEMPERATURETESTERS• DiST™5 μS scale and DiST™6 mS scale

• Waterproof and floating

• Replaceable graphite electrode

• Dual-level LCD

• Greater accuracy The graphite conductivity probe resists contamination by salt deposits in the solution.

• BEPS (Battery Error Prevention System)

• Automatic Calibration

• Automatic Temperature Compensation

• HOLD button freezes readings on the display

• Automatic shut-off

ORDERING INFORMATIONHI 98311 (DiST®5) and HI 98312 (DiST®6) aresupplied with EC/TDS probe, probe removal tooland batteries.

PROBESHI 73311 Spare probe

ACCESSORIESHI 73128 Probe removal tool

SPECIFICATIONS HI 98311 (DiST®5) HI 98312 (DiST®6)

Range

EC 0 to 3999 μS/cm 0.00 to 20.00 mS/cm

TDS 0 to 2000 mg/L (ppm) 0.00 to 10.00 g/L (ppt)

Temperature 0.0 to 60.0°C / 32.0 to 140.0°F

Resolution

EC 1 μS/cm 0.01 mS/cm

TDS 1 mg/L (ppm) 0.01 g/L (ppt)

Temperature 0.1°C / 0.1°F

Accuracy (@20°C)

EC ±2% F.S.

TDS ±2% F.S.

Temperature ±0.5°C / ±1°F

Battery Type (4) 1.5V

See Page 34for more infoon testing soilusing a slurry

Page 8: Hanna Instruments Agricultural Products Catalog 2010

Conductivity/TDS“EC” stands for Electrical Conductivity. Electrical conductivity is defined asthe ability of a substance to conduct an electrical current. Conductivity in asolution is directly proportional to the concentration of salts. Conductivityis temperature dependent and will rise in proportion to a temperature increase. As a result, it is important to consider an instrument that will automatically account for the temperature coefficient. Growers shouldconduct conductivity measurements to ensure the optimal level of nutrients are being delivered to their plants.

2 Scales for Measuring EC and TDSEC (Electrical Conductivity) is recorded in mS (milliSiemens) or μS (MicroSiemens). 1 mS = 1000 μS

TDS (Total Dissolved Solids) is a proportion of EC and is usually recordedin ppm (parts per million). Three common proportion multiplying factors,0.7 (hydroponics), 0.64 (soil science) and 0.5 are used to convert EC to TDS. Ex.: If the measured EC is 1000 μS, this can be converted bymultiplying it by 0.7 (hydroponics) which equals 700 ppm.

EC Chart (solution EC vs. ppm N) Checking EC for Common Blended Fertilizer and Fertilizer Salts*

Formula1 50 100 150 200 300 40021-7-7 0.28 0.56 0.84 1.12 1.68 2.23

9-45-15 0.60 1.20 1.80 2.41 3.60 4.82

20-20-20 0.20 0.40 0.60 0.80 1.20 1.60

20-10-20 0.33 0.66 0.99 1.32 1.98 2.63

21-5-20 0.29 0.58 0.93 1.16 1.86 2.33

17-5-17 0.32 0.64 0.96 1.28 1.92 2.56

13-2-13 0.34 0.68 1.02 1.36 2.04 2.72

14-0-14 0.34 0.68 1.02 1.36 2.04 2.72

15-0-15 0.37 0.74 1.11 1.48 2.22 2.96

Ammonium nitrate 0.24 0.48 0.72 0.96 1.44 1.92

Ammonium phosphate 0.36 0.71 1.08 1.42 2.14 2.84

Calcium nitrate 0.31 0.63 0.94 1.26 1.88 2.51

Magnesium nitrate 0.55 1.09 1.64 2.18 3.28 4.36

Potassium nitrate 0.27 0.56 0.83 1.11 1.66 2.231N-P205-K20 formula *Values may change from manufacturer. Please refer to actual manufactuters chart for your particular fertilizer.

Calculate ppm N from a 20-10-20 fertilizer solution with a total EC of 1.8 mS and usingirrigation water with an EC of 0.5 mS

EC of Fertilizer Solution EC of Water EC of Only

the Fertilizer

1.8 mS 0.5 mS 1.3 mS

From the chart above, 20-10-20 with an EC of 1.3 Ms would give a concentration ofabout 200 ppm N.

To predict the EC of 20-10-20 at 200 ppm N using an irrigation water with an EC of 0.5 mS.

EC of 20-10-20 at 200 ppm N EC of Water EC of Ferftilizer

Solution

1.3 mS 0.5 mS 1.8 mS

Sometimes, the EC of the fertilizer solution coming out of the hose is not what you expect. The problem can be caused by an incorrect dilution rate from the injector, either brokenor not properly adjusted, or the fertilizer stock concentration is wrong.

To check the fertilizer concentration, take a small amount from the stock solution, dilutethis in water to the target ratio, and check the EC. For example, if you think your injectoris set at 1:100, then put 10 mililiters into one liter of water (this will also give a 1:100 dilu-tion). If the EC of the solution is where it should be, then it is an injector problem. If theEC of the hand-diluted solution is off-target, then the stock concentration is not correct.

-

-

+

+

=

=

=

=

8

cond

ucti

vity

v.6agcat

ORDERING INFORMATIONHI 8730, HI 8731 and HI 8732 are supplied with conductivity probe with built-in temperature sensor, calibration solution sachets, battery and instructions.

PROBESHI 761285 Conductivity probe with built-in temperature sensor, DIN connector and 1 m (3.3’) cable

HI 8730 • HI 8731 • HI 8732EC, TDS AND TEMPERATURE METERS• Water-tight contruction

• Automatic Temperature Compensation

• Easy maintenance probe with a built-in temperature sensor

HI 8730, HI 8731 and HI 8732 are complete, versatile and water-tight conductivity meters that are lightweight and easy to maintain.

These meters can be calibrated at one point for EC or TDS, while the temperature range is factory calibrated.

SPECIFICATIONS HI 8730 HI 8731 HI 8732

Range

EC 0 to 1990 μS/cm 0 to 6000 μS/cm 0.00 to 4.00 mS/cm

TDS 0 to 1990 mg/L(ppm)

0 to 3000 mg/L(ppm)

0 to 1999 mg/L(ppm)

Temp. 0 to 70.0°C

Resolution

EC 10 μS/cm 10 μS/cm 0.01 mS/cm

TDS 10 mg/L(ppm)

10 mg/L(ppm)

1 mg/L(ppm)

Temp. 1°C 0.1°C 0.1°C

Accuracy(@20°C)

EC/TDS ±2% F.S.

Temp. ±1°C ±0.5°C

TDS Factor 0.5 0.5 Variable, 0.56 to 0.72

Battery Type (1) 1.9V

Electrical Conductivityof Total dissolved salts

EC

Page 9: Hanna Instruments Agricultural Products Catalog 2010

v.6agcat With Great Products, Come Great Results™

conductivity

9

ORDERING INFORMATIONHI 993310 is supplied with plastic body conductivity probe, probe with stainless steel conic tip fordirect soil measurements, soil preparation solution, battery, instructions and rugged carrying case.

PROBESHI 76305 Stainless steel probe for direct soil measurementHI 76304 EC probe for solution and soil sample measurement

ACCESSORIESHI 721319 Ground augerHI 710010 Shockproof rubber boot, orange

HI 993310DIRECT SOIL ACTIVITY AND SOLUTION CONDUCTIVITY KIT• Supplied with 2 probes for measurement versatlity

• Automatic Temperature Compensation

• Equipped with BEPS (Battery Error Prevention System)

HI 993310 is an instrument that has been specifically designed to address the need for conductivity measurementsin soil and liquids. It is supplied with two probes: HI 76305 witha stainless steel conical tip for direct soil measurement and HI 76304 for fertilizer enriched solutions.

HI 993310 measures both the soil conductivity in EC (mS/cm)as well as salt activity (g/L). The different scales can be selected through two keys on the front panel and two separateLEDs indicate which parameter is being tested. In addition, HI 993310 is equipped with an alarm LED that automaticallyturns on if the soil is too dry or nutritive substances such aspotassium or nitrogen are lacking. Demineralized water canbe added to the soil prior to proceeding with further tests.

Direct soil measurement is performed by HI 76305 stainlesssteel probe.

Why This Meter is So Important...Conductivity is an important factor in greenhouses and hydro-ponics and is measured in soil as well as in fertilizer solutions. Conductivity of soil is an excellent indication for the presenceof nutritive salts. Soil conductivity is checked before and afterfertilization to establish its effectiveness as well as ensuringthat the soil is not too saline or damaging to the plant roots. Conductivity of the irrigation water and fertilizer mixes arechecked to make sure values are within an acceptable rangeand a correct fertilizer concentration strength is being applied.

SPECIFICATIONS HI 993310

RangeEC 0.00 to 19.99 mS/cm

Salt activity 0.00 to 1.00

Resolution EC 0.01 mS/cm g/L

Salt activity 0.01 g/L

Accuracy (@20°C/68°F) ±2% F.S. (0 to 15.00 mS/cm; excluding probe error)

Battery Type (1) 9V

HI 99300 • HI 99301 EC/TDS/TEMPERATURE METERS• Amperometric technology

• Waterproof

• Multi-level LCD display

• HOLD button Freezes readings on the display

• Automatic Temperature Compensation

• Automatic single calibration with calibration indicator

• BEPS (Battery Error Prevention

• Battery % displayed on startup.

• Easy to clean and keep clean

HI 99300 and HI 99301 are portable, microprocessor-based EC/TDS and temperature meters. The EC/TDS probe resists clogging and is easy to clean by design.

SPECIFICATIONS HI 99300 HI 99301

Range

EC 0 to 3999 μS/cm 0.00 to 20.00 mS/cm

TDS 0 to 2000 ppm (mg/L) 0.00 to 10.00 ppt (g/L)

Temp. 0.0 to 60.0°C/32.0 to 140.0°F

Resolution

EC 1 μS/cm 0.01 mS/cm

TDS 1 ppm (mg/L) 0.01 ppt (g/L)

Temp. 0.1°C/0.1°F

Accuracy(@20°C)

EC/TDS ±2% F.S.

Temp. ±0.5°C/±1°F

Battery Type (3) 1.5V AAA

ORDERING INFORMATIONHI 99300 and HI 99301 are supplied with EC/TDS probe, starter set ofcalibration solution sachets, batteries and instructions.

ELECTRODESHI 76306 EC/TDS probe with built-in temperature sensor, DIN connector and 1 m (3.3’) cable

ACCESSORIESHI 710020 Orange protective rubber bootHI 710021 Blue protective rubber boot

Page 10: Hanna Instruments Agricultural Products Catalog 2010

v.6agcat

mul

tipa

ram

eter

10

ORDERING INFORMATIONHI 991300 and HI 991301 are supplied with HI 1288 pH/EC/TDS/temperature probe, starter set of calibration solution sachets, batteries, instructions and hard carrying case.

ELECTRODESHI 1288 Pre-amplified pH/EC/TDS probe with built-in temperature sensor, DIN connector and 1 m (3.3’) cable

ACCESSORIESHI 710020 Orange protective rubber bootHI 710021 Blue protective rubber boot

SPECIFICATIONS HI 991300 HI 991301

Range

pH 0 to 14.00 pH

EC 0 to 3999 μS/cm 0.00 to 20.00 mS/cm

TDS 0 to 2000 ppm (mg/L) 0.00 to 10.00 ppt (g/L)

Temp. 0.0 to 60.0°C/32.0 to 140.0°F

Resolution

pH 0.01 pH

EC 1 μS/cm 0.01 mS/cm

TDS 1 ppm (mg/L) 0.01 ppt (g/L)

Temp. 0.01°C/0.1°F

Accuracy(@20°C)

pH ±0.01 pH

EC/TDS ±2% F.S.

Temp. ±0.5°C/±1°F

Battery Type (3) 1.5V AAA

• Protective Rubber Boot The optional rubber boot helps protect your meter

HI 991300 • HI 991301pH/EC/TDS/TEMPERATURE METERS• Waterproof to IP 67

• Multi-level LCD display

• HOLD feature

• Automatic Temperature Compensation

• Automatic 1 or 2 point calibration

• BEPS (Battery Error Prevention System)

• Battery % displayed on startup.

• Heavy-duty

• Easy to clean and keep clean

SPECIFICATIONS HI 98129 HI 98130

Range

pH 0.00 to 14.00 pH

EC 0 to 3999 μS/cm 0.00 to 20.00 mS/cm

TDS 0 to 2000 mg/L (ppm) 0.00 to 10.00 g/L (ppt)

Temperature 0.0 to 60.0°C / 32.0 to 140.0°F

Resolution

pH 0.01 pH

EC 1 μS/cm 0.01 mS/cm

TDS 1 mg/L (ppm) 0.01 g/L (ppt)

Temperature 0.1°C / 0.1°F

Accuracy (@20°C)

pH ±0.05 pH

EC / TDS ±2% F.S.

Temperature ±0.5°C /±1°F

Battery Type (4) 1.5V

• Dual-level LCD

• Cloth, renewable junction

• Automatic 2 point pH calibration

• Automatic 1 point calibration for EC and TDS

• BEPS (Battery Error Prevention System)

• Battery % displayed at startup

• Automatic Temperature Compensation

• Waterproof and floating

• HOLD button to freeze readings on the display

• Automatic shut-off

• EC/TDS graphite electrode

• Replaceable pH Electrode The stainless steel round connector means there are no pins to bend or break.

• Exposed Temperature Sensor Provides fast response time and high accuracy in temperature compensated readings.

ORDERING INFORMATIONHI 98129 (Combo) and HI 98130 (Combo) aresupplied with batteries, pH electrode and electrode removal tool.

ELECTRODESHI 73127 Spare pH electrode

ACCESSORIESHI 73128 Electrode removal tool

HI 98129 • HI 98130pH/CONDUCTIVITY/TDS TESTERS

See Page 34for calibrationinstructionsand more infoon testing soilusing a slurry

Page 11: Hanna Instruments Agricultural Products Catalog 2010

Shown with HI 710008protective boot (optional)

HI 9811-5

v.6agcat With Great Products, Come Great Results™

multiparam

eter

11

HI 9813-5 • HI 9813-6 • HI 9811-5pH/EC/TDS/ºC PORTABLEMETERS• Water resistant

• Exclusive CAL CHECK™ feature Alerts users of calibration status (HI 9813-6 only)

• On-screen user guides Save time with on-screen calibration guides

• BEPS (Battery Error Prevention System)

• Switch parameters at the touch of a button

• Automatic Temperature Compensation For pH and conductivity

• Simple calibration Dials located on the front panel makes calibration quick and simple, even for non-technical users

• Battery % displayed on startup

• Specialized Rugged Probe The 1285 series probes are designed to withstand harsh environments such as fertilizer solutions.

• Protective Rubber Boot The optional rubber boot helps protect your meter

HI 9813-6, HI 9813-5 and HI 9811-5 are versatile, waterresistant multiparameter portable meters specifically designed for agricultural applications such as hydroponics,greenhouses, farming and nurseries.

HI 1285 Series ProbesThe specially engineered HI 1285-5 and HI 1285-6 pH/EC/TDS/temperature probes utilize a fiber junction and gelelectrolyte to provide fast response times and reducedcontamination. This combination makes these probes particularly suitable to be used in fertilizer solutions.

These probes are interchangeable with other pH metersthat use the same connector.

ORDERING INFORMATIONHI 9811-5, HI 9813-5 and HI 9813-6 are supplied with HI 1285-5 (for HI 9811-5, HI 9813-5) or HI 1285-6 CAL CHECK™ (forHI 9813-6) combination probe with DIN connector & 1 m (3.3') cable,starter set of calibration and cleaning solution sachets, check solution sachet (HI 9813-6 only), battery and instructions.

PROBESHI 1285-5 Combination, amplified pH/EC/TDS/temperature probe with built-in temperature sensor, 8-pin DIN connector and 1 m (3.3') cable.HI 1285-6 Combination, amplified pH/EC/TDS/temperature probe with CAL CHECK™ feature, built-in temperature sensor, 8-pin DIN connector and 1 m (3.3') cable.

SPECIFIC SOLUTIONSHI 50021P Check solution, (25) 20 mL sachets

OTHER ACCESSORIESHI 710007 Shockproof rubber boot, blueHI 710008 Shockproof rubber boot, orange

SPECIFICATIONS HI 9811-5 HI 9813-5 HI 9813-6 (Cal Check™)

Range

pH 0.0 to 14.0 pH 0.0 to 14.0 pH

EC 0 to 6000 μS/cm 0.00 to 4.00 mS/cm

TDS 0 to 3000 ppm (mg/L) 0 to 1999 ppm (mg/L)

Temperature 0.0 to 70.0°C 0.0 to 60.0°C

Resolution

pH 0.1 pH 0.1 pH

EC 10 μS/cm 0.01 mS/cm

TDS 10 ppm (mg/L) 1 ppm (mg/L)

Temperature 0.1°C 0.1°C

Accuracy(@20°C/68°F)

pH ±0.1 pH ±0.1 pH

EC ±2% F.S. ±2% F.S.

TDS ±2% F.S. ±2% F.S.

Temperature ±0.5°C ±0.5°C

Battery Type (1) 9V (1) 9V

HI 9813-6 EXCLUSIVE CAL CHECK™ FEATUREHI 9813-6’s CAL CHECK™ feature allows the user to check the meter calibration status atany time using by checking the HI 1285-6 probe against HI 50021 check solution.

If “Clean Probe and Calibrate” is displayed, just immerse the probe in HI 700661 cleaningsolution for 5 minutes. Re-calibration is needed if “Clean Probe and Calibrate” messageis displayed again after cleaning.

• Specialized Rugged Probe The 1285 series probes are designed to withstand harsh environments such as fertilizer solutions.

Page 12: Hanna Instruments Agricultural Products Catalog 2010

12

NPK

v.6agcat

TEST RANGE METHOD REAGENT CODEAluminum 0.00 to 1.00 mg/L (ppm) Aluminon HI 93712-01Alkalinity 0 to 500 mg/L (ppm) Colorimetric HI 93755-01Ammonia MR 0.00 to 10.00 mg/L (ppm) Nessler HI 93715-01Ammonia LR 0.00 to 3.00 mg/L (ppm) Nessler HI 93700-01Bromine 0.00 to 8.00 mg/L (ppm) DPD HI 93716-01Calcium 0 to 400 mg/L (ppm) Oxalate HI 937521-01**Chlorine Dioxide 0.00 to 2.00 mg/L (ppm) Chlorophenol Red HI 93738-01Chlorine*, Free 0.00 to 2.50 mg/L (ppm) DPD HI 93701-01Chlorine*, Total 0.00 to 3.50 mg/L (ppm) DPD HI 93711-01Chromium VI HR 0 to 1000 μg/L Diphenylcarbohydrazide HI 93723-01Chromium VI LR 0 to 300 μg/L Diphenylcarbohydrazide HI 93749-01Color 0 to 500 PCU Colorimetric Platinum Cobalt —Copper HR 0.00 to 5.00 mg/L (ppm) Bicinchoninate HI 93702-01Copper LR 0 to 1000 μg/L Bicinchoninate HI 95747-01Cyanuric Acid 0 to 80 mg/L (ppm) Turbidimetric HI 93722-01Fluoride 0.00 to 2.00 mg/L (ppm) SPADNS HI 93729-01Hardness (calcium) 0.00 to 2.70 mg/L (ppm) Colorimetric HI 93720-01Hardness (magnesium) 0.00 to 2.00 mg/L (ppm) Colorimetric HI 93719-01Hydrazine 0 to 400 μg/L p-Dimethylaminobenzaldehyde HI 93704-01Iodine 0.0 to 12.5 mg/L (ppm) DPD HI 93718-01Iron HR 0.00 to 5.00 mg/L (ppm) Phenantroline HI 93721-01Iron LR 0 to 400 μg/L TPTZ HI 93746-01**Magnesium 0 to 150 mg/L (ppm) Calmagite HI 937520-01**Manganese HR 0.0 to 20.0 mg/L (ppm) Periodate Oxidation HI 93709-01Manganese LR 0 to 300 μg/L PAN HI 93748-01**Molybdenum 0.0 to 40.0 mg/L (ppm) Mercaptoacetic Acid HI 93730-01Nickel HR 0.00 to 7.00 g/L Photometric HI 93726-01

Nickel LR0.000 mg/L to

1.000 mg/L (ppm)PAN HI 93740-01**

Nitrate 0.0 to 30.0 mg/L (ppm) Cadmium Reduction HI 93728-01Nitrite HR 0 to 150 mg/L (ppm) Ferrous Sulfate HI 93708-01Nitrite LR 0.00 to 0.35 mg/L (ppm) Diazotization HI 93707-01Oxygen, Dissolved (DO) 0.0 to 10.0 mg/L (ppm) Winkler HI 93732-01Ozone 0.00 to 2.00 mg/L (ppm) DPD HI 93757-01pH 6.5 to 8.5 pH Phenol Red HI 93710-01Phosphate HR 0.0 to 30.0 mg/L (ppm) Amino Acid HI 93717-01Phosphate LR 0.00 to 2.50 mg/L (ppm) Ascorbic Acid HI 93713-01Phosphorus 0.0 to 15.0 mg/L (ppm) Amino Acid HI 93706-01Potassium HR 20 to 200 mg/L (ppm) Turbidimetric Tetraphenylborate HI 93750-01Potassium MR 10 to 100 mg/L (ppm) Turbidimetric Tetraphenylborate HI 93750-01Potassium LR 0.0 to 20.0 mg/L (ppm) Turbidimetric Tetraphenylborate HI 93750-01Silica 0.00 to 2.00 mg/L (ppm) Heteropoly blue HI 93705-01Silver 0.000 to 1.000 mg/L (ppm) PAN HI 93737-01**Sulfate 0 to 150 mg/L (ppm) Turbidimetric HI 93751-01Zinc 0.00 to 3.00 mg/L (ppm) Zincon HI 93731-01

* For Chlorine, liquid reagents are available.. ** Reagents for 50 tests

ORDERING INFORMATIONHI 83200 is supplied with cuvettes (4), bottle for DOtest, batteries, 12 Vdc adapter and instructions.

SOLUTIONSHI 93703-50 Cuvette cleaning solution, 230 mL

ACCESSORIESHI 83900-30 Lysimeter with 30 cm (0.98’) tube HI 83900-60 Lysimeter with 60 cm (1.97’) tube HI 83900-90 Lysimeter with 90 cm (2.95’) tubeHI 731318 Cuvette cleaning cloth (4)HI 731321 Glass cuvettes (4 pcs)HI 731325N Cuvette caps (4)HI 740034 Cap for 100 mL beaker (6)HI 740036 100 mL plastic beaker (6)HI 740038 60 mL glass bottle and stopperHI 740142 1 mL graduated syringeHI 740143 1 mL graduated syringe (6)HI 740144 Pipette tip (6)HI 740157 Plastic pipette (20)HI 740220 25 mL glass cylinder with cap (2)HI 740223 170 mL plastic beakerHI 740224 170 mL plastic beaker (12)HI 740225 60 mL graduated syringeHI 740226 5 mL graduated syringeHI 740227 Filter assemblyHI 740228 Filter disc (25)HI 740229 100 mL Polypropylene cylinderHI 740230 Demineralized water, 230 MLHI 92000 Windows® Compatible SoftwareHI 920010 PC connection cableHI 93703-54 Dried resin (100 g)HI 93703-55 Activated Carbon (50)

HI 83200MULTIPARAMETER PHOTOMETER• PC compatible via USB

• User friendly prompts and auto- diagnostic messages on LCD

• Powered by 9V batteries or 12 VDC

• Fast, affordable results

You no longer need to send off your samplesand wait for the results to come back since the HI 83200 is one of the most versatile, photometers on the market providing lab graderesults, quickly and easily.

This practical instrument measures nutrientscommonly present in fertilizer-enriched solu-tions such as ammonia, phosphorus, nitrateand potassium in three distinct ranges of low,medium and high concentrations. This way ac-curacy is maximized for each nutrient and forevery concentration.

Using the HI 83200, you can test the presenceand strength of nutrients right on the spot.This can translate itself into a substantial savings and improved yield.

Page 13: Hanna Instruments Agricultural Products Catalog 2010

13

NPK

With Great Products, Come Great Results™ v.6agcat

Plant NutritionThe three elements that are most neededby plants are nitrogen (N), phosphorous(P) and potassium (K). This is the reasonwhy they are called macronutrients andshould be given to plants.

Nitrogen is indispensable for the plant’slife and is a key factor in fertilization. Nitrogen allows the development of thevegetative activity of the plant, in particu-lar, causes lengthening of trunks andsprouts and increases the production offoliage and fruits. An excess of nitrogenweakens the plants’ structure creating anunbalanced relationship between theleaves and the stalks. In addition, theplant becomes less resistant to diseases.

Phosphorous is an important element inthe composition of DNA and RNA, the reg-ulators of the energetic exchange (ATP &ADP), as well as the reserve substances inseeds and bulbs. It contributes to the formation of buds, roots, blooming, andlignification.

A lack of phosphorous results in: stiflingof plant, slow growth, a reduction of production, smaller fruits and a lower expansion of the roots.

Even if Potassium is not a constituent ofimportant compounds, it plays a remark-able role in many physiological activitieslike the control of cellular turgor and the ac-cumulation of carbohydrates. It increasesthe size of fruits, their flavor, as well asyielding a positive effect on the color andfragrance of flowers. Potassium also makesplants more resistant to disease.

1. Rubber cap2. Soil solution sampler tube3. Porous ceramic tip

4. 30 mL syringe (pump)5. Rubber suction capillary6. Finger clamp

HI 83900SUCTION LYSIMETER FOR ROOT LEVEL SOIL MONITORING• Perfect companion to the HI 83200

• Monitor soil composition right at the roots

• Easy to use

The HI 83900 suction lysimeter is built with a porous ceramic cap connected to a transparent tubefor soil solution extraction. A rubber capillary is inserted in the tube passing through a rubber capand reaching the ceramic tip.

The HI 83900 series lysimeter is an ideal tool for collecting soil solution samples and then performquantitative chemical analysis. In this way the operator can easily monitor the level of nutrients,such as ammonia, nitrate, phosphorous and potassium, sulfate, calcium, magnesium.

The ceramic tip of the lysimeter can be used in all types of soil, and it is made of sinterized materialthat does not react with nutrient elements. The soil solution, therefore, is not affected by the chem-ical composition of the ceramic cap and the test results are always precise and reliable.

The HI 83900 allows the extraction of a solution from the soil by creating a vacuum (negative pressure or suction) inside the sampler tube, that exceeds the soil water tension. This will establish an hydraulic gradient for the solution to flow through the porous ceramiccap and into the lysimeter tube. Typically, a vacuum of about -60 cb (centibar) should be drawn.

For better monitoring of soil solution composition throughout an entire growth period of crops, atleast two lysimeters should be installed in the root zone of a representative plant—one at the upperpart and the other in the lower part of the root zone.

For better accuracy and repeatability of results, it is recommended to replicate the above describedinstallation in at least two more locations.

ORDERING INFORMATIONHI 83900-30 is comprised of 30 cm (0.98’) tube sampler tube ending with porous ceramic tip, capillary rubber tubewith rubber cap and finger clamp, cleaning solution stater kit, 30 mL syringe and instructions.HI 83900-60 is comprised of 60 cm (1.97’) tube sampler tube ending with porous ceramic tip, capillary rubber tubewith rubber cap and finger clamp, cleaning solution stater kit, 30 mL syringe and instructions.HI 83900-90 is comprised of 90 cm (2.95’) tube sampler tube ending with porous ceramic tip, capillary rubber tubewith rubber cap and finger clamp, cleaning solution stater kit, 30 mL syringe and instructions.

ACCESSORIESHI 83900-25 Cleaning solution kit, 500 mL

Available in 3 LengthsHI 83900-3030 cm (0.98’)

HI 83900-6060 cm (1.97’)

HI 83900-9090 cm (2.95’)

Page 14: Hanna Instruments Agricultural Products Catalog 2010

14

suga

r (br

ix)

v.6agcat

Poor Average Good ExcellentFruitsApples 6 10 14 18+Avocados 4 6 8 10+Bananas 8 10 12 14+Cantaloupe 8 12 14 16+Casaba 8 10 12 14+Cherries 6 8 14 16+Coconut 8 10 12 14+Grapes 8 12 16 20+Grapefruit 6 10 14 18+Honeydew 8 10 12 14+Kumquat 4 6 8 10+Lemons 4 6 8 12+Limes 4 6 10 12+Mangos 4 6 10 14+Oranges 6 10 16 20+Papayas 6 10 18 22+Peaches 6 10 14 18+Pears 6 10 12 14+Pineapple 12 14 20 22+Raisins 60 70 75 80+Raspberries 6 8 12 14+Strawberries 6 10 14 16+Tomatoes 4 6 8 12+Watermelon 8 12 14 16+GrassesAlfalfa 4 8 16 22+Grains 6 10 14 18+Sorghum 6 10 22 30+

Poor Average Good ExcellentVegetableAsparagus 2 4 6 8+Beets 6 8 10 12+Bell Peppers 4 6 8 12+Broccoli 6 8 10 12+Cabbage 6 8 10 12+Carrots 4 6 12 18+Cauliflower 4 6 8 10+Celery 4 6 10 12+Corn Stalks 4 8 14 20+Corn (Young) 6 10 18 24+Cow Peas 4 6 10 12+Endive 4 6 8 10+English Peas 8 10 12 14+Escarole 4 6 8 10+Field Peas 4 6 10 12+Green Beans 4 6 8 10+Hot Peppers 4 6 8 10+Kohl Rabi 6 8 10 12+Lettuce 4 6 8 10+Onions 4 6 8 10+Parsley 4 6 8 10+Peanuts 4 6 8 10+Potatoes, Irish 3 5 7 8+Potatoes, Red 3 5 7 8+Potatoes, Sweet 6 8 10 14+Romaine 4 6 8 10+Rutabagas 4 6 10 12+Squash 6 8 12 14+Sweet Corn 6 10 18 24+Turnips 4 6 8 10+

HI 96801 • HI 96811DIGITAL BRIX REFRACTOMETERSFOR SUGAR ANALYSIS• Quick, Precise Results Readings are displayed in approximately 1.5 seconds.

• Dual Level LCD Displays primary measurement and temperature simultaneously.

• Easy Measurement Place a few drops of the sample in the well and press the READ key.

• Small Sample Size Sample size can be as small as 2 metric drops.

• IP 65 Waterproof Protection Built to perform under harsh laboratory and field conditions.

• Stainless Steel Sample Well Easy to clean and corrosion resistant.

• Single Point Calibration Calibrate with distilled or deionized water.

• B.E.P.S. (Battery Error Prevention System) Alerts you in the event that low battery power could affect readings.

• Automatic Shut-off

• Automatic Temperature Compensation

Brix is measured with a refractometer and is the determination of howmuch sugar is in the plant sap. Brix is really important as it is a direct measurement of how well the plant is performing. The sugar moleculeproduced in the phytosynthesis process is the building block we see grow-ing above and below the ground in the form of leaves, stems, fruit,branches and roots.

ORDERING INFORMATIONHI 96801 and HI 96811 are supplied with battery and instructions.

SPECIFICATIONS HI 96801 HI 96811

RangeSugar Content 0 to 85 %Brix 0 to 50 %Brix

Temperature 0 to 80°C (32 to 176°F)

ResolutionSugar Content ±0.1 %Brix

Temperature ±0.1°C (0.1°F)

Accuracy (@20°C)

Sugar Content ±0.2 %Brix

Temperature ±0.3°C (0.5°F)

Battery Type (1) 9V

Refractive Index of Crop Juices - Calibrated in % Sucrose or BRIX

Page 15: Hanna Instruments Agricultural Products Catalog 2010

SPECIFICATIONS HI 9143

Range

O2 0.00 to45.00 mg/L (ppm)

% Saturation O2 0.0 to 300.0%

ºC 0.0 to 50.0°C

Resolution

O2 0.01 mg/L (ppm)

% Saturation O2 0.1%

ºC 0.1°C

Accuracy (@ 20°C/68°F)

O2 ±1.5% F.S

% Saturation O2 ±1.5% F.S

ºC ±0.5°C

Power Supply (4) 1.5V AA batteries; inputfor 12 Vdc power adapter

SPECIFICATIONS HI 9142Range 0.0 to 19.9 mg/L (ppm)

Resolution 0.1 mg/L (ppm)

Accuracy (@20°C/68°F) ±1.5% F.S.

Battery Type (4) 1.5V AA

ORDERING INFORMATIONHI 9142 is supplied with HI 76407/4 DO probe with 4 m(13’) cable, (2) spare membranes, HI 7041S electrolytesolution (30 mL), calibration screewdriver, batteries, instructions and protective case.

ACCESSORIESHI 7041S Refilling electrolyte solution, 30 mL HI 7040L Zero oxygen solution, 500 mL HI 76407A/P Replacement membranes (5)

HI 9142DISSOLVED OXYGENMETER • Automatic temperature compensation

• Affordable and efficient

• Designed for harsh conditions

Dissolved Oxygen MetersDissolved Oxygen is a term commonly used for the measurement of the amount of free molecular oxygen (O2) dissolved in a unit volume of water usually expressed in milligrams perliter (mg/l), parts per million (ppm), or percent saturation. Dissolved Oxygen is an indicator ofwater quality.

In agriculture, growers should measure the dissolved oxygen if their primary water source isa natural body of water such as a stream, pond, or well. Low Dissolved Oxygen in irrigationwater encourages disease and poor growth.

Hydroponic growers should be measuring DO to ensure there is sufficient oxygen in their irrigation water that is being transferred to the roots of their plants.

15

dissolved oxygen

With Great Products, Come Great Results™ v.6agcat

HI 8410DISSOLVED OXYGENCONTROLLER• Extended range to 50 mg/L (ppm)

• Manual single point calibration

• Selectable 0-20 or 4-20 mA output

• Low maintenance Galvanic probe

• Backlit LCD

• Operational mode LED indicators

• Transparent splash-proof cover

• Recorder output

• Setpoint and alarm relay

• Dosing and over dosing control

• Setpoint, alarm and hysteresis ranges

The HI 8410 is an extended range panelmounted Dissolved Oxygen (DO) controller thatis used to maintain and monitor the concentra-tion of DO in a wide range of agricultural appli-cations. The HI 8410 utilizes a Galvanic probeand typically requires less maintenance than aPolarographic style making it ideal for long termmonitoring. Calibration is single set point andcan be done in zero oxygen solution.

SPECIFICATIONS HI 8410

Range0.0 to 50.0 mg/L (ppm) O2

0 to 600 % O2-5.0 to 50.0 °C

Resolution 0.1 mg/L (ppm) or 1% (O2) / 0.1 °C

Accuracy(@20°C/68°F) ±1% of reading (O2) / ±0.2 °C

Power Supply 115 Vac ±10% or 230 Vac ±10%; 50/60 Hz

ORDERING INFORMATIONThe HI 8410 is supplied complete with mounting brack-ets and instructions.

ProbeHI 76409/4 Galvanic DO probe with built-in temperature sensor and 4 m cableHI 76409/10 Galvanic DO probe with built-in temperature sensor and 10 m cable

ORDERING INFORMATIONHI 9143 is supplied with HI 76407/4 DO probewith 4 m (13’) cable, (2) spare membranes, HI 7041S electrolyte solution (30 mL), batter-ies, instructions and protective case.

ACCESSORIESHI 7041S Refilling electrolyte solution, 30 mL HI 7040L Zero oxygen solution, 500 mL HI 76407A/P Replacement membranes (5)

HI 9143DISSOLVED OXYGENMETER• Altitude, salinity and temperature compensation

• HOLD button to freeze reading on the display

Simple on-site calibration requires no chemical solu-tions. Just expose the probe to air and press the CALbutton. In a few minutes, the meter is calibrated andready to use. Auto-calibration eliminates the need touse a screwdriver or other devices to adjust the reading.

Page 16: Hanna Instruments Agricultural Products Catalog 2010

16

rela

tive

hum

idit

y

v.6agcat

ORDERING INFORMATIONHI 93640 is supplied with battery

ACCESSORIESHI 710011 Probe sintered capHI 7102 Calibration chamber for probes with sintered capHI 710007 Blue Shockproof rubber bootHI 710008 Orange Shockproof rubber boot

HI 93640THERMO-HYGROMETER WITH BUILT-IN SENSOR • Portability and simplicity

• Low battery indicator

• Dual temperature range

SPECIFICATIONS HI 93640

RangeRH 5.0 to 95.0%

Temperature 0.0 to 60.0°C ; 32 to 140°F

ResolutionRH 0.1%

Temperature 0.1°C; 1°F

AccuracyRH ±2%

Temperature ±0.4°C; ±1°F (excluding probe error)

Battery Type (1) 9V

Shown with optionalprotective rubber boot

HI 9565THERMO-HYGROMETER WITH DEW POINT • Backlit LCD

• Auto shut-off

• Calibration data-logging probe

• HOLD button

ORDERING INFORMATIONHI 9565 are supplied with RH/temperature probe, battery, instruction manual and protective case.

ELECTRODESHI 70602 RH probe with temperature sensor, 1 m (3.3’)

SPECIFICATIONS HI 9565

Range

RH 20.0 to 95.0%

Temperature 0.0 to 60.0°C / 32 to 140.0°F

Dew Point -20.0 to 60.0°C / -4.0 to 140.0°F

Resolution

RH 0.1% RH

Temperature 0.1°C / 0.1°F

Dew Point 0.1°C / 0.1°F

Accuracy

RH ±3 % RH (50 to 85 % RH & 15 to 40°C); ±5% RH (outside)

Temperature ±0.5°C / ±1°F

Dew Point ±2°C /±4°F (50 to 85 % RH & 15 to 40°C); ±4.5°C /±9°F (outside)

Battery Type (1) 9V

ORDERING INFORMATIONHI 8666 is supplied with sensor protective cap, mounting brackets and instructions

ACCESSORIESHI 710011 Probe sintered cap

HI 8666RELATIVE HUMIDITY AND TEMPERATURE TRANSMITTER• Removable sintered metal cap

• Dual-range, compact transmitter

• Can be quickly removed for maintenance with minimal downtime

• Fast response time

This solid-state transmitter plugs into its wall-mounted receptacle foron-site, continuous monitoring of relative humidity and temperature incritical or controlled environments.

SPECIFICATIONS HI 8666

RangeRH 0% (4 mA) to 100% (20 mA)

temperature -20°C (4 mA) to 60°C (20 mA)

AccuracyRH ±2% (5% to 95% RH)

temperature ±1% F.S.

Page 17: Hanna Instruments Agricultural Products Catalog 2010

17

lux (light) • liquid level

With Great Products, Come Great Results™ v.6agcat

ORDERING INFORMATIONHI 97500 is supplied with battery, sensor on 1.5 m (4.9’cable), protective case and instructions.

HI 97500PORTABLE LUXMETER• Three measurement ranges

• Rugged, waterproof case

• Low-battery indicator

The Quality of LightQuality of light is very important in the workplace, schools, greenhouses and public buildings.Too little light (or luminous intensity) affects the quantity and quality of performance of bothpeople and crops. HANNA's light meter uses special optic filters to match the spectral sensitivityof the human eye.

Luminous intensity is measured and reported in foot-candles (ft-c) or in lux (lx). Light metersare commonly referred to as lux meters. One lux is equal to one lumen per square meter and onefoot-candle is equal to one lumen per square foot. To convert measurements use the followingformula:

foot-candle = lux x 0.0929

lux = foot-candle x 10.764

HANNA's light measuring sensor is a photo diode that converts incident light into an electronicsignal that is read and displayed on the meters LCD as Klx which is 1,000 lx. So multiply the read-ing by 92.9 to get the measurement in foot candles.

Plant Light RequirementsLight provides the energy source needed for plants to manufacture food (photosynthesis). Theamount of light is commonly measured in foot-candles (ft-c) or lux. Plants differ greatly in theirlight intensity requirements. Indoor plants are often classified by the amount of light necessaryfor growth:

• Low (minimum 1.1 Klx, .8 to 2.1 preferred for good growth)• Medium (minimum 1.1 to 1.6 Klx, 2.1 to 5.4 preferred)• High (minimum 1.6 to 10.8 Klx, 5.4 to 10.8 preferred)• Very high (minimum 10.8 Klx, 10.8+ preferred)

About 1.1 Klx for 12 hours per day are necessary simply to maintain plant quality for one yearand at least 2.1 Klx for 12 hours per day are necessary for foliage plants to manifest any benefitfrom fertilization.

While lack of sufficient light results in poor plant growth, too much light can also be harmful.Shade plants cannot tolerate excessively high light levels. When a plant receives too much directlight, the leaves bleach or scald, sometimes dying. This often happens after moving a plant out-doors in direct light. Any changes in light intensity should be gradual.

luxSPECIFICATIONS HI 97500

Range 0.001 to 1.999 Klux; 0.01 to 19.99 Klux;0.1 to 199.9 Klux

Resolution 0.001 Klux; 0.01 Klux; 0.1 Klux

Accuracy ±6% of reading ±2 digits

Sensor human-eye-response silicon photodiode

Battery Type (1) 9V alkaline

HI 7871 • HI 7873MINI LEVEL CONTROLLERSHI 7871 and HI 7873 mini level controllers areideal for liquid level control over distances of upto 100 m (330’). The are highly compact andwill fit in tight spaces.

These easy-to-use controllers are ideal for liquidlevel applications such as nutrient tank control.

HI 7871 features high and low level control,while HI 7873 includes an overflow alarm. Both instruments are connected to a 2-wiretransmitter (HI 7874), which is ideal for levelmonitoring in remote applications.

A complete liquid level measuring system requires:1) A controller (HI 7871 or HI 7873)2) A bar holder with amplifier circuitry (HI 7874)3) A package of measuring bars (HI 731324)4) An undecal connector (HI 7164)HI 7871 requires 3 bars, one each for low and high levels and the third as a consent sensor. HI 7873 requires 4 bars with the additional bar used for overflow measurement.

ORDERING INFORMATIONHI 7871/115 and HI 7873/115 (115 Vac) and HI 7871/220 and HI 7873/220 (220 Vac) are supplied with mounting brackets and instructions.

ACCESSORIESHI 7874 Level transmitter with internal amplifierHI 7164 Undecal connectorHI 731324 Stainless steel threaded measuring bars (5)

SPECIFICATIONS HI 7871 HI 7873Transmission max 100 m (330’)

Electrical Connection

HI 7164 undecal connector (not included)

Level Adjustment high and low high, low andoverflow

Level Indication high and low high, low andoverflow

Sensor Bars3 (not included) 4 (not included)

(HI 731324 pack of 5)

Transmitter HI 7874 (not included)

Output Contact 1 relay (2A/250Vac, 30 Vdc)

2 relays (2A/250Vac, 30 Vdc)

Page 18: Hanna Instruments Agricultural Products Catalog 2010

18

tem

pera

ture

v.6agcat

ORDERING INFORMATIONHI 98502 (Checktemp®F) is supplied with penetrationprobe, protective cap, battery and instructions.

SPECIFICATIONS HI 98502 (Checktemp®F)

Range -58.0 to 302.0°F

Resolution 0.1°F (58.0 to 199.9°F);1°F (200 to 302°F)

Accuracy ±0.5°F (-4 to 194°F)±1°F (outside)

Battery Type (1) 1.5V

Checktemp® is provided with the CAL CHECK®function: simply activate a switch and the instrument will simulate an ice bath at 32.0°F.The LCD should display readings within a rangeof ±0.3°C (±0.5°F). CAL CHECK® guaranteesaccuracy every time!

The sharp-tip probe of the Checktemp® easilypenetrates semi-solid mediums, making rou-tine checks quick and effortless.

HI 98502 CHECKTEMP® DIGITAL THERMOMETER

HI 143T-LOGGERwith Locking Wall Cradle

• Logging start through PC by pressing a button or at a set time

• Selectable sampling interval from 1 minute to 24 hours

• Up to 4,000 logged samples

• Selectable measurement unit, °C or °F

• IP65 water resistant protection

• Min/Max values are stored and displayed

• Programmable high and low alarms

• Non-volatile storage of logging parameters and data

• Battery level indicator on display

• Security password supported software

• Ideal for GAP certification

The HI 143 is controlled via USB or RS232 on a PC with HANNA’s Windows® compatible application software. The supplied wall cradlemakes it easy to lock the meter in place to pre-vent tampering and the application softwaresupports security passwords.

SPECIFICATIONS HI 143Range -30. to 70.0°C/-22.0 to 158.0°F

Resolution 0.1°C/0.1°F

Accuracy

±0.4°C (-20 to 60°C); ±0.6°C (outside)

±0.7°F (-4 to 140°C); ±1.1°F (outside)

Battery Type (1) CR2032 3V lithium ion

ORDERING INFORMATIONHI 143-00 is supplied with USB communication cradle,Windows® compatible application software, lithium battery, wall cradle, lock and instructions.HI 143-10 is supplied with RS232 communication cradle,Windows® compatible application software, lithium battery, wall cradle, lock and instructions.HI 143 is supplied with lithium battery, wall cradle, lockand instructions (software and comm. cradle required).

ACCESSORIESHI 143002 USB communication cradle.HI 143001 RS232 communication cradle.

Soil TemperatureSoil temperature is critical for propagation. Each plant has an ideal germination and rooting temperature. In addition, knowing the soil temperature is imperative when battling pests and diseases. Since certain pests thrive in certain soil temperatures, having that information can reallyhelp you stay ahead of the game.

• Non-Invasive measurement

• External probe can also be used

• 1 second IR response time

• ºC models available: HI 99556-00 (-10 to 300ºC) and HI 99556-10 (-20.0 to 199.9ºC)

The HI 99556 thermometer employs infraredtechnology to measure surface temperatures. Infrared readings are extremely fast with a response time typically around 1 second.

In order to measure the temperature, simplypoint to the product or target and hold downthe measurement key.

If you also need to check the core temperature,simply attach the external probe.

HI 99556-00DUAL INFRARED/PROBETHERMOMETER

SPECIFICATIONS HI 99556-01

RangeIR 14 to 572°F

Probe -40 to 302°F

ResolutionIR 1°F

Probe 1°F

Accuracy

IR ±2% of reading or ±3°F

Probe ±1°F (0 to 250°F); ±1°F +1% reading (outside)

Battery Type (1) 9V

ORDERING INFORMATIONHI 99556-01 is supplied with internal IR sensor, externaltemperature probe, battery and instructions.

PROBESHI 765PW Temperature probe for HI 99556

• CAL CHECK®

• NO MERCURY or other hazardous materials

• Fast response time

• Very durable

• Easy to read LCD

• ºC model available (HI 98501)

Page 19: Hanna Instruments Agricultural Products Catalog 2010

The monitoring of chlorine is crucial in applications such as fruit and vegetable sanitation and disinfection. By mon-itoring this crucial parameter, serious health and safetyrisks can be avoided.

These Checker®HC’s are extremely simple to use. First,zero the instrument with your water sample. Next, addthe reagent. Last, Place the vial into the Checker®HC,press the button and read the results. It’s that easy.

See Page 34 for more information on measurement.v.

6agcat With Great Products, Come Great Results™

intruments for irrigation w

ater sanitation (Cl2 /OR

P)

19

What is Chlorine and ORP?Disinfection is a process of killing disease-causing organisms(or pathogens). Chlorine (Cl2) is a commonly used disinfec-tant because when mixed with pure water, it reacts toform hypochlorous acid (HOCl) and hydrochloric (HCl).HOCl (free active chlorine) is the most effective form ofchlorine for disinfection.

ORP stands for Oxidation Reduction Potential. OxidationReduction Potential is the potential at which oxidation occurs. In simple terms, ORP measurements allow for easymonitoring and tracking of critical disinfectant levels. Theideal ORP range for continuous disinfection is between650 and 700mV.

Chlorine Use in Irrigation waterChlorine can be an effective sanitizer in irrigation waterapplications. Some applications include:

• Recycling irrigation water

• Sanitizing irrigation water from natural sources such as ponds, rivers, streams or wells.

• Maintain and clean sprinkler and nozzle heads

• Clean up algae growing on walls, benches and soil surfaces

• Sanitizing produce

Calcium and sodium hypochlorite are widely used to con-trol waterborne pathogens and algae in irrigation water.We are most familiar with these materials as liquid bleach(sodium hypochlorite) and solid swimming pool “shock”(calcium hypochlorite)

HANNA Options for Measuring Chlorine and ORPHANNA has a long history of providing a wide range of instrumentation for measuring Chlorine and ORP. Theyrange from portable pH/ORP meters and Chlorine photometers, to in-line sanitation systems that combinethe continuous monitoring and controlling of chlorine concentration with the safe validation of ORP monitoring.

ORDERING INFORMATIONHI 711 Checker®HC is supplied with (2) sample cuvettes with caps, (6) powder reagents for TotalChlorine, battery and instructions.HI 701 Checker®HC is supplied with (2) sample cuvettes with caps, (6) powder reagents for FreeChlorine, battery and instructions.

REAGENTS AND STANDARDSHI 711-25 Reagents for 25 tests (Total Cl2)HI 701-25 Reagents for 25 tests (Free Cl2)

ACCESSORIESHI 731318 (4) Cuvette cleaning clothHI 731321 (4) Glass cuvettesHI 731225 (4) Caps for cuvettesHI 93703-50 Cuvette cleaning solution, 230 mL

SPECIFICATIONS HI 711 (Total Chlorine) HI 701 (Free Chlorine)Range 0.00 to 3.50 ppm (mg/L) 0.00 to 2.50 ppm (mg/L)

Resolution 0.01 ppm (mg/L)

Accuracy ±3% of reading ±0.03 ppm (mg/L) @ 25°C

Battery Type (1) 1.5V AAA

Easier to use and more accurate thanchemical test kits EPA approved DPD method Large, easy to read digits Auto shut-off

Dedicated to a single parameter Works with HANNA’s powder reagents Uses 10 mL glass cuvettes

Small Size, Big Convenience The Checker®HC easily fits into the palm of your hand or pocket Use for quick and accurate on the spot analysis Single button operation: Zero and Measure Operated by a single AAA battery

HI 701 • HI 711FREE AND TOTAL CHLORINE HANDHELDCOLORIMETERS

Visit www.hannachecker.com for more Checker HC’sto measure ions such as Iron and Phosphate.

Page 20: Hanna Instruments Agricultural Products Catalog 2010

20

intr

umen

ts fo

r irr

igat

ion

wat

er s

anit

atio

n (C

l 2/O

RP)

v.6agcat

HI 96711 • HI 96734FREE AND TOTAL CHLORINEPHOTOMETERS

ORDERING INFORMATIONHI 96711 and HI 96734 is supplied with (2) sample cuvettes with caps, 9V batteryand instructions.CAL CHECK™ standards and reagents sold separately

REAGENTS AND STANDARDSHI 96711HI 93701-01 Reagents for 100 tests (Free Cl2)HI 93701-03 Reagents for 300 tests (Free Cl2)HI 93711-01 Reagents for 100 tests (Total Cl2)HI 93711-03 Reagents for 300 tests (Total Cl2)HI 95701-11 CAL CHECK™ Standard Cuvettes for Free Cl2 (1 set)HI 95711-11 CAL CHECK™ Standard cuvettes for Total Cl2 (1 set)HI 96734HI 93701-01 Reagents for 100 tests (Free Cl2)HI 93701-03 Reagents for 300 tests (Free Cl2)HI 93734-01 Powder reagents for 100 tests (Free or Total Cl2)HI 93734-03 Powder reagents for 300 tests (Free or Total Cl2)HI 95734-11 CAL CHECK™ Standard cuvettes

SPECIFICATIONSHI 96711

FREE AND TOTALCHLORINE

HI 96734 UHR FREE AND TOTAL

CHLORINE

RangeFree Chlorine 0.00 to 5.00 mg/L (ppm) 0.00 to 10.00 mg/L (ppm)

Total Chlorine 0.00 to 5.00 mg/L (ppm) 0.00 to 10.00 mg/L (ppm)

Resolution 0.01 mg/L (0.10 mg/L over3.50 mg/L) (ppm)

0.01 mg/L (0.10 mg/L above3.50 mg/L) (ppm)

Accuracy ±0.02 mg/L @ 1.00 mg/L(ppm)

±0.06 mg/L to 3.00 mg/L(ppm)

Power Supply (1) 9V battery

Method Adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G.

• CAL CHECK™

• Large, dual-level LCD

• Water-resistant

• Accuracy verification

• User calibration

• Certified calibration and verification standards

• Secondary standards for calibration and verification

• BEPS (Battery Error Prevention System)

• READ/TIMER function

• Auto shut-off

• Calibration Date on Display

SPECIFICATIONS HI 991003

Range

pH -2.00 to 16.00 pHpH-mV ±825 mV (pH-mV)ORP ±1999 mV

Temperature -5.0 to 105.0°C/ 23.0 to 221.0°F

Resolution

pH 0.01 pHpH-mV 1 mVORP 1 mVTemperature 0.1°C/0.1°F

Accuracy(@20°C)

pH ±0.02 pHpH-mV ±1 mVORP ±2 mV

Temperature

±0.5°C (up to 60°C); ±1.0°C (outside);

±1.0°F (up to 140°F); ±2.0°F (outside)

Battery Type (3) 1.2V AAA

ORDERING INFORMATIONHI 991003 is supplied with pH/ORP/temperature electrode, starter set of calibration and cleaning solutionsachets, batteries, instructions and hard carrying case.

ELECTRODESHI 1297D Pre-amplified pH/ORP electrode with built-in temperature sensor, DIN connector and 1 m (3.3’) cable

ACCESSORIESHI 710023 Orange protective rubber bootHI 710024 Blue protective rubber boot

HI 991003pH, pH-MV, ORP/ TEMPERATUREMETER • Sensor Check™ Electrode status check• Waterproof

• Multi-level LCD Display

• HOLD button Freezes readings on display

• Automatic Temperature Compensation

• Automatic 1 or 2 Point Calibration

• BEPS (Battery Error Prevention System)

• Battery % displayed on startup.

• Flat tip pH/temperature electrode with titanium body and mini pre-amplifier

• Bottom probe connection Assures the cable doesn’t get in your way

HI 991003 incorporates our Sensor Check™feature that allows users to determine electrode status at any time.

The HI 1297D pH electrode features a recessed flat tip that is easy to clean and prevents solids in solutions from collecting onthe sensor. • Protective Rubber Boot

Page 21: Hanna Instruments Agricultural Products Catalog 2010

v.6agcat With Great Products, Come Great Results™

intruments for irrigation w

ater sanitation (Cl2 /OR

P)

21

HI 98121pH/ORP TESTER• Waterproof and floating

• HANNA’s exclusive cartridge pH electrode

• Extendable cloth pH junction

• Dual-level LCD

• Automatic Temperature Compensation

• Automatic Calibration

• Battery % level at startup and stability indicator

• HOLD button to freeze readings on the display

SPECIFICATIONS HI 98121

Range

ORP ± 1000 mV

pH -2.00 to 16.00 pH

Temperature -5.0 to 60.0°C / 23.0 to 140.0°F

Resolution

ORP 1 mV

pH 0.01 pH

Temperature 0.1°C / 0.1°F

Accuracy(@20°C)

ORP ±2 mV

pH ±0.05 pH

Temperature ±0.5°C / ±1°F

Battery Type (4) 1.5V

In some applications,ORP can be used to determine the effectsof soil compaction andthe viability of the soilto maintain the properlevel of oxygen.

ORPORP stands for oxidation reduction potential. ORP is a reading in millivoltsthat provides a measurement of thesample’s ability to oxidize (or sanitize)contaminants. Water ionizers are in-tended to raise the alkalinity of your tapwater to counteract the in-take of acids.The water sample should show a nega-tive ORP value after the ionizationprocess has been applied to your water.

ORP Preparation and Measurement1) Remove the protective cap. Visible

residue from salt deposits is common. Rinse off any deposits with water.

2) For faster response times, treat the ORP platinum (metal) surface prior to use by soaking it in pre-treatment solution for 15 minutes. Generally useHI 7092M Oxidizing pre-treatment solution when planning on measuring+mV ORP readings. If you are planningon measuring -mV ORP readings, use HI 7091M reducing pre-treatmentsolution.

3) If pre-treatment is not performed, the electrode will take significantly longer time to respond. Additionally, the recently pre-treated electrode (metal) surface will dissolve off over time so it will have to be restored by future pre-treatments.

4) To measure ORP, immerse the tip of the tester in the sample, stir gently and wait for the reading to stabilize.

orp

ORDERING INFORMATIONBL 932700-0 (12 Vdc) and BL 932700-1 (115/230 Vac) are supplied withmounting brackets, transparent protective cover and instruction manual.

PROBESHI 2001 ORP electrode for continuous flow-thru monitoring

GENERAL ACCESSORIESHI 740146 Mounting brackets

Accurate and Simpleto InstallOur line of simple-to-operate controllershave been specially designed for agri-cultural applications including hydro-ponics or applications where space orcost are a major concern. Thanks to theircompact size, they can be mounted inconfined spaces and right next to tanksor vats. The low cost of these meters willmake it possible for processes that weremanually maintained to be controlledautomatically, saving considerable timeand money.

SPECIFICATIONS BL 932700Range ±1000 mV

Resolution 1 mV

Accuracy (@20°C/68°F) ±5 mV

Dosing Relay 1, max 2A (fuse protected), 250 Vac, 30 Vdc

Dosing Selection

reducing or oxidizingcontact open=reducing dosage,

activated when reading exceeds setpoint value; contact closed=oxidizing dosage,

activated when reading falls below setpoint value

• Any System Can be Cost Effectively Monitored 24 Hours A Day!

BL 932700ORP MINI CONTROLLER• Fire retardant casing

• Approximately 3.3 x 2.1 x 3.9”

• Large LCD

• Selectable overdose protection system and control override

• External disable feature

• Matching pin connection

• 4-20 mA recorder outputDon’t forget—you can fit

these controllers into ourNEMA boxes!

ORDERING INFORMATIONHI 98121 (ORP/pH) is supplied with pH elec-trode, electrode removal tool and batteries.

ELECTRODESHI 73127 Spare pH electrode

• Negative ORP measurements require extra cleaning to remove electrolyte deposits

Please see our cleaning solutions in the back of this catalog

Page 22: Hanna Instruments Agricultural Products Catalog 2010

ORDERING INFORMATIONHI 9912 is supplied complete with instructions.

SOLUTIONSHI 7004/1L pH 4.01 buffer solution, 1 LHI 7007/1L pH 7.01 buffer solution, 1 LHI 7010/1L pH 10.01 buffer solution, 1 LHI 7020L 200-275 mV test solution, 500 mL HI 7021L 240 mV test solution, 500 mL HI 7022L 475 mV test solution, 500 mL

HI 9912 -Choose your Configuration:

SPECIFICATIONS HI 9912Range 0.00 to 14.00 pH; 0 to 1000 mV

Resolution 0.01 pH; 1 mV

Accuracy(@20°C/68°F) ±0.02 pH; ±5 mV

Dosing Contact powered terminals for pH and ORP corrections (240V) Max. 2A, 1,000,000 strokespH dosage: activated when pH > setpoint; ORP dosage: activated when mV < setpoint

Alarm Relay

activated when pH varies more than a selectable value (0.5 to 2.5 pH) from setpointor when max dosage time for pH (adjustable from 1 to 10 minutes) elapses;

or activated when mV reading varies more than a selectable value (50 to 250 mV) from setpointor when max dosage time for ORP (adjustable from 1 to 10 minutes) elapses

Power Supply 110/115 Vac ±10% or 220/240 Vac ±10%; 50/60 Hz

HI 9912pH & ORP DIGITALCONTROLLERwith Proportional Control

• 2 user adjustable setpoints

• Automatic temperature compensation

• 2 point calibration

• Alarm relay

• Proportional control

HI 9912 is a pH and ORP controller specially designed for sanitization. Two separate setpoints canbe user-adjusted from 6 to 8 pH and 500 to 900 mV. The relays are activated when the pH exceedsor the mV falls below the relevant setpoint. HI 9912 accepts any pH and ORP electrode ending in auniversal BNC connector. Two independent terminals provide for pH and ORP ground probes to ex-tend electrode life and eliminate interference.

HANNA’s proportional control allows considerable savings by minimizing the use of chemicals. Thesettings are made through independent time cycles adjustable from 0 to 90 seconds and two pro-portional bands from 0 to 200 mV and 0 to 2 pH. Two pumps or electro-valves can be wired directlyto the controller and be powered through the terminal.

22

intr

umen

ts fo

r irr

igat

ion

wat

er s

anit

atio

n (C

l 2/O

RP)

v.6agcat

Summary of results from various lab simulation and commercial hydrocooler survey studies

Survival at ORP (mV)

Pathogen/IndicatorE.coli 0157:H7

< 485 550 x < 620 > 665

> 300 s < 60 s < 10 s

Salmonella spp. > 300 s > 300 s < 20 s

L. monocytogenes > 300 s > 300 s < 20 s

Thermotolerant coliform > 48 h > 48 h < 30 s

• Purify recycled irrigation water with excellent results

• Clean algae growing on walls, benches and surfaces

• Sanitize produce

• Safe levels of chlorine from 0.00-5.00 ppm is assured

• Constant monitoring of pH,ORP and temperature

• Utilizes low cost, readily available sanitizers

• Data logging and transfer

• Alarm capacity

• Sanitization reports can be generated

Constant Monitoring with a Simple,Proven MethodChlorine is a common and effective sanitizer for reducing harmful bacteriasuch as salmonella, pythium and e. coli. The HI SANI chlorination systemutilizes inexpensive, convenient and easy to use sodium hypochlorite orchlorine gas.

To ensure proper control, HANNA has linked two control systems. Onesystem controls the volume of the sanitizer from 0.00 to 5.00 ppm, theother is a function of ORP (oxidation reduction potential).

ORP lets you to determine if the sanitation occurring is safe and adequate.

HI SANIGREENHOUSE AND AGRICULTURESANITATION SYSTEMS

ORDERING INFORMATIONHI SANI Contact your local HANNA representative for more information.

1= 115 Vac power supply2= 230 Vac power supply

Page 23: Hanna Instruments Agricultural Products Catalog 2010

23

continuous pH (acid) m

onitoring/control

With Great Products, Come Great Results™ v.6agcat

• Combine pH with an EC controller for continuous monitoring

• NEMA protection

• Simple to Install - plug in probe, power & relay meter

BL 7916pH CONTROLLER AND PUMP

ORDERING INFORMATIONBL 981411-0 (12 Vdc) and BL 981411-1 (115/230 Vac)

PROBESHI 1001 pH electrode for continuous flow-thru monitoring

BL 981411pH MINI CONTROLLER

ORDERING INFORMATIONBL 931700-0 (12 Vdc) and BL 931700-1 (115/230 Vac)

PROBESHI 1001 pH electrode for continuous flow-thru monitoring

BL 931700pH MINI CONTROLLER

SPECIFICATIONS BL 981411Range 0.0 to 14.0 pH

Resolution 0.1 pH

Accuracy (@20°C/68°F) ±0.1 pH

SPECIFICATIONS BL 983327Range 0.00 to 10.00 mS/cm

Resolution 0.01 mS/cm

Accuracy (@20°C/68°F) ±2% f.s.

SPECIFICATIONS BL 931700Range 0.00 to 14.00 pH

Resolution 0.01 pH

Accuracy (@20°C/68°F) ±0.02 pH

with 4-20 mA Recorder

Output

ORDERING INFORMATIONBL 983327-0 (12 Vdc) and BL 983327-1 (115/230 Vac)

PROBESHI 7632-00 EC/TDS probe with internal temperature sensor and 2 m cable

BL 983327EC MINI CONTROLLER

HI 1211 • HI 1222CONTINUOUS pH (ACID) ANDEC/TDS (FERTILIZER) MONITORINGAND CONTROLLING SYSTEMS.

HANNA offers a wide range of in-line solutionsthat allows growers the ability to continuouslymonitor and if desired control the pH (acid) andEC (fertilizer). These controllers will allow anysystem to be cost effectively monitored 24hours a day.

ORDERING INFORMATIONHI 1222 Dual controller NEMA boxHI 1211 Single controller NEMA box

HI 1222Dual Controller Capability NEMA Enclosure

HI 1211Single Controller Capability NEMA Enclosure

ORDERING INFORMATIONBL 7916-1 (110/115V) and BL 7916-2 (220/240V) aresupplied with discharge and suction valves, polyethyl-ene tubing, power cable and instructions.

ACCESSORIESHI 721101 Pumphead, O-ring and screwsHI 721102 Discharge valve assemblyHI 721103 Suction valve assemblyHI 721004 Injection valve assembly (required)HI 721005 Foot valve assembly (required)HI 721008 Ceramic weight (4 pcs.)

• ±0.01 pH accuracy and high performance

• Proportional, Acid or Base and user selectable dosing

• Proportional dosing slows the pump down when the measured pH level approaches the set value ensuring precise dosing and avoiding over dosage.

• Alarm contact is activated whenever the pH value varies more than 2 pH units from the set point.

• Isolated 4 to 20 mA recorder output.

• Auxiliary contacts to attach a mixer or priming pump that activates only when pump is dosing.

• Use in vegetable dunk tank to assure and verify sanitation for GAP compliance

SPECIFICATIONS BL 7916Range 0.00 to 14.00 pH

Resolution 0.01 pH

Accuracy (@20°C/68°F) ±0.01 pH

PRESSURE (BAR) FLOW RATE (LPH)0.5 13.31.0 11.72.0 10.13.0 9.04.0 7.8

Page 24: Hanna Instruments Agricultural Products Catalog 2010

v.6agcat

fert

igat

ion

24

HI 9913 is a 2-in-1 pH and conductivitycontroller engineered for dosage offertilizer solutions in hydroponics.

HI 9913 accepts pH electrodes withBNC and conductivity probes with DINconnectors.

HI 9913INDUSTRIAL GRADE pH & CONDUCTIVITYDIGITAL CONTROLLERwith Proportional Control for Fertigation

ORDERING INFORMATIONHI 9913 is supplied complete with instructions.

SPECIFICATIONS HI 9913Range 0.00 to 14.00 pH; 0.00 to 10.00 mS/cm

Resolution 0.01 pH; 0.01 mS/cm

Accuracy (@20°C/68°F) ±0.02 pH; ±2% F.S.

Dosing Contact powered terminals for pH and EC dosages (240V) Max. 2A, 1,000,000 strokesactivated when pH > setpoint and when mS reading < setpoint, respectively

Alarm Relay

activated when pH varies more than a selectable value (0.5 to 2.5 pH) from setpointor when max dosage time for pH (adjustable from 1 to 10 minutes) elapses; or whenconductivity varies more than a selectable value (0.5 to 2.5 mS/cm) from setpoint or

when max dosage time for EC (adjustable from 1 to 10 minutes) elapses (isolated,Max 2A-240 V, resistive load, 1,000,000 strokes)

PROBESHI 3001D Conductivity probe for in-line or submersion applications

SOLUTIONSHI 7004/1L pH 4.01 buffer solution, 1 LHI 7007/1L pH 7.01 buffer solution, 1 LHI 7031L 1413 μS/cm calibration solution, 500 mLHI 7039L 5000 μS/cm calibration solution, 500 mL

1= 115 Vac power supply2= 230 Vac power supply

HI 9913 -Choose your Configuration:

HI 9935 is a pH and TDS controller for fertilizer solution dosage in hydroponics. Two sep-arate setpoints can be user-adjusted from 4 to 7 pH and 900 to 1800 ppm (mg/L). The relays are activated when the pH exceeds the setpoint or TDS falls below the desired value.Two pumps or electro-valves can be wired directly to the controller and be powered throughthe terminals. Independent proportional settings for pH and TDS can be adjusted from 0 to 90 seconds, 0 to 2.0 for pH and 0 to 400 mg/L (ppm) for TDS. A ground probe can beconnected to the appropriate terminals to extend electrode life and eliminate interference.

pH electrodes with a BNC connector and TDS probes with a DIN connector are accepted.

HI 9935pH & TDS DIGITAL CONTROLLERwith Proportional Control for Fertigation

ORDERING INFORMATIONHI 9935 is supplied complete with instructions.

SPECIFICATIONS HI 9935

Range 0.00 to 14.00 pH; 0 to 1999 ppm (mg/L)

Resolution 0.01 pH; 1 ppm (mg/L)

Accuracy (@20°C/68°F) ±0.02 pH; ±2% F.S.

TDS Conversion Factor 0.65 mg/L (ppm) = 1 μS/cm

Dosing Contact powered terminals for pH and TDS corrections (240 V) Max. 2A, 1,000,000 strokesactivated when pH > setpoint and TDS reading < setpoint, respectively

Alarm Relay

activated when pH varies more than a selectable value (0.5 to 2.5 pH) from setpoint orwhen max dosage time for pH (adjustable from 1 to 10 minutes) elapses;

or when TDS differs more than a selectable value (50 to 450 mg/L (ppm) from setpoint orwhen max dosage time for TDS (adjustable from 1 to 10 minutes) elapses(isolated, Max

2A-240 V, resistive load, 1,000,000 strokes)

PROBESHI 3001D Conductivity probe for in-line or submersion applications

SOLUTIONSHI 7004/1L pH 4.01 buffer solution, 1 L HI 7007/1L pH 7.01 buffer solution, 1 LHI 70442L 1500 mg/L (ppm) calibration solution, 500 mL

HI 9935-Choose your Configuration:

• 2 user adjustable setpoints

• Automatic temperature compensation

• 2 point calibration

• Alarm relay

• 2 user adjustable setpoints

• Automatic temperature compensation

• 2 point calibration

• Alarm relay

1= 115 Vac power supply2= 230 Vac power supply

Page 25: Hanna Instruments Agricultural Products Catalog 2010

v.6agcat With Great Products, Come Great Results™

fertigation

25

HI 9914FERTIGATION DIGITAL CONTROLLER for Agricultural Process Control Requirements

HI 9914 is a wall mounted fertigation controller designedto meet specific process control requirements in agricul-tural, horticultural and hydroponics applications.

The controller includes two regulators for pH and conduc-tivity, that can be adjusted from the front panel by settingtwo independent thresholds. The conductivity and pH con-trols are time separated and a timed operation mode toavoid overdosing of fertilizer or acid. The controller status isindicated by LEDs on the front panel. Moreover, the equip-ment is provided with a three-level sensor, to control thewater level, the alarm condition and irrigation sequences.

The instrument also features an alarm system, which isactivated when an unusual working condition occurs. Ahumidity detector can be used to stop the controller if anyleakage is detected. Water nozzle, circulation pump, feed-ing pump and alarm are equipped with relays.

PROBESHI 3003D Conductivity probe for in-line or submersion applications

SOLUTIONSHI 7004L pH 4.01 buffer solution, 500 mLHI 7007L pH 7.01 buffer solution, 500 mLHI 7031L 1.41 mS/cm cal. solution, 500 mLHI 7039L 5.00 mS/cm calibration solution, 500 mL

ORDERING INFORMATIONHI 9914 is supplied complete with instructions.

SPECIFICATIONS HI 9914Range 0.00 to 10.00 mS/cm; 0.00 to 14.00 pH

Resolution 0.01 mS/cm; 0.01 pH

Accuracy (@20°C/68°F) ±5% F.S.; ±0.02 pH

HI 9914 -Choose your Configuration:

ORDERING INFORMATION*-1 models utilize a 110/115 Vac power supply-2 models utilize a 220/240 Vac power supplyBL 1.5-1 and BL 1.5-2 1.5 LPH flow rateBL 3-1 and BL 3-2 2.9 LPH flow rateBL 5-1 and BL 5-2 5.0 LPH flow rateBL 7-1 and BL 7-2 7.6 LPH flow rateBL 10-1 and BL 10-2 10.8 LPH flow rateBL 15-1 and BL 15-2 15.2 LPH flow rateBL 20-1 and BL 20-2 18.3 LPH flow rate

ACCESSORIES

HI 721101 Pumphead, O-ring and screws

HI 721102 Discharge valve assembly

HI 721103 Suction valve assembly

HI 721004** Injection valve assembly

HI 721005** Foot valve assembly

HI 721008 Ceramic weight (4 pcs.)

** Required for operation

SPECIFICATIONS BL SERIESMax Output see table below

Pump Casing fiber-reinforced polypropylene

Materials pumphead in PVDF, diaphragm in PTFE, glass ball valves and O-rings inFPM/FKM polyethylene 5 x 8 mm tubing and 3/8" injection fitting

Power Supply 110/115 Vac (-1 models) or 220/240 Vac (-2 models), 50/60Hz

Protection IP65

PART NUMBERMAX

OUTPUT LPH

RATED PRESSURE

BAR

DOSING FREQUENCY

STROKES/MINWITH LARGE DIAPHRAGM BL 20 18.3 0.5 120

BL 15 15.2 1 120

BL 10 10.8 3 120

BL 7 7.6 3 120

WITH SMALL DIAPHRAGMBL 5 5.0 7 120

BL 3 2.9 8 120

BL 1.5 1.5 13 120

BL SeriesCHEMICAL DOSINGPUMPS • Ideal for dosing nutrients and acids

• Designed for all environments

• Solenoid driven, minimum moving parts used

• Vertical or horizontal mounting

• Single control operation

• Affordable

• High Quality Materials Blackstone pumps are supplied with the highest quality material as standard equipment— not optional. The diaphragm utilizes one-piece construction of PTFE that, unlike conventional laminated diaphragms, stands up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF, PTFE and FPM/FKM which offer unsurpassed resistance even to the most aggressive chemicals.

Blackstone pumps are more accurate than standard pumps due to the positive displacement design ensuring each stroke is identical to the strokes before and after it,thus keeping the flow rate consistent.

A wide range of Blackstone pumps with different dosing capacities are available for yourspecific needs. Each pump is supplied with discharge and suction valves.

1= 115 Vac power supply2= 230 Vac power supply

Page 26: Hanna Instruments Agricultural Products Catalog 2010

26

fert

igat

ion

v.6agcat

1. Fertilizer and acid injection indicators (LEDs)

2. Main pump and alarm indicators (LEDs)

3. Multiple zone valve indicators (LEDs)

4. Waterproof NEMA 4X casing

5. Multiple connection ports

6. Up to 62 selectable “screens” for readouts and programming

7. Touch keypad

8. Quick reference guide

of our acid injection/pH control systemsheartthe

HI 8000 SeriesACID INJECTION/pH CONTROL SYSTEMSTrue pH and Alkalinity control solutions for variable flow greenhouse irrigationAdvanced features of HANNA’s HI 8000 Series Controllers:

• Free installation and start up

• Combined pH and flow control technology

• Multiple measuring point monitoring and control from the point of injection to the point of delivery — all from one central controller

• Precise fertilizer control with multiple point EC monitoring

• Automatic time or volume control from 8 to 32 zones (solenoid valves)

• 10 easy to use programs for a variety of crops and irrigation timetables

• Programmable starts for “hand watering” or time scheduled activation

• Multiple alarm settings to provide maximum safety and reliability

• PC interface capability for remote monitoring and control

• Fully upgradeable to a 4 fertilizer injection control system

• Maintains selected pH within fluctuating alkalinity and flow rates

• 2 year warranty on the HI 8000 Controller and free unlimited technical support

HANNA instruments®, the world’s leader in pH technology has worked with leadinggreenhouses to develop advanced system solutions for covered crops of any type. Eachsystem can precisely control pH and alkalinity from 3GPM up to 200GPM. Incorporatingcombined pH and flow control technology, the HANNA solution offers features and func-tionality found no where else in the industry.

Each system can be installed in-tank or directly in-line and is custom configured and programmed to meet the pH and alkalinity requirements of any greenhouse—any crop!

1

2 3

45

6

7

8

Page 27: Hanna Instruments Agricultural Products Catalog 2010

SPECIFICATIONS HI 8,000 SERIES (HEAD UNIT)Range pH : 0.0 to 14.0; EC: 0.0 to 10.0 mS/cm

Resolution 0.1 pH / 0.1 mS/cm

Accuracy (@20°C/68°F) pH: ±0.0546; EC: ±0.078 mS/cm

Typical Inputs2 pH electrodes, 3 conductivity probes, 4 fertilizer tanks, 1 acid tank, 5 tank

level controls, 1 mixing tank level control, 2 differentialpressures, 1 irrigation counter, 1 temporary break, 1 conditional stoppage

Typical Outputs 2 non-consent alarms, up to 32 zone valves, 2 filter flushing, pump, agitator, 4 fertilizer tank electro-valves, 1 pH tank electro-valve

Number of Programs 10

Program Method With keypad or through a PC using proprietary software

Irrigation Capacity 1, 4, 8 and 32 zone valves

Irrigation Control time/volume control, 1 to 6 different timetables per program,

REQUIRED ACCESSORIESHI 98143-22 pH/EC isolated transmitter, non-sourcing currenttype with 4-20 mA output (2 required)

ACCESSORIESHI 60542 2" NPT in-line PVC and ORP electrode holder ideal for installation directly in pipes. The HI 60542 has been designed specifically to be used with HANNA’s 3⁄4" process pH and ORP electrodes.

QUICK RELEASECONNECTIONS

DIRECT INJECTIONSPRAYER NOZZLE

BLEEDER VALVES

Firmware language00: English 01: Spanish 02: Italian 03: Portuguese

04: Dutch 05: French 06: Greek 07: Arabic

Mount Style1: panel mounted 2: wall mounted

Number of sectors01: 8 sectors 04: 32 sectors

Power SupplyU: 115 Vac D: 230 Vac

ORDERING INFORMATIONContact your nearest HANNA for more information on how the HI 8,000 can benefit your greenhouse.

HI 800 -

Acids Used for Irrigation Water Acidification

Type of Acid

Specific Gravity

Amount of acid per 100 gallons needed to remove 1 ppm CaCO3 of alkalinity

Nutrients addedwith 1 fluid ounceof acid per gallon

75% Phosphoric 1,58 grams/ml 0.021 fl.oz. 32 ppm P

85% Phosphoric 1.69 grams/ml 0.017 fl.oz. 36 ppm P

35% Sulfuric 1.26 grams/ml 0.028 fl.oz. 11 ppm S

93% Sulfuric 1.83 grams/ml 0.007 fl.oz. 30 ppm S

61% Nitric 1.38 grams/ml 0.019 fl.oz. 17 ppm N

Ex.: The amount of 85% phosphoric acid per 100 gallons of water needed to remove 200 ppm CaCO3

of alkalinity.

Alkalinity removed (in ppm CaCO3)

Fluid ounces of acid to remove 1 ppm alkalinity

Total fluid ounces of acid

200 0.017 3.4 fl.oz.

Ex.: The concentration of phosphorus (in ppm P) added when 3.4 fluid ounces of phosphoric acid per 100 gallons is added

Volume of acid added (in fluid ounces)

Nutrients supplied with the addition of 1 fluid ounce per 100 gallons

Amount of P added

3.4 36 122 ppm P

x

x

x

x

=

=

=

=

27

fertigation

With Great Products, Come Great Results™ v.6agcat

Choose your Configuration:

Page 28: Hanna Instruments Agricultural Products Catalog 2010

to 115 V electrical

outlet

BL series pump BL series

pump

HI 1222

Water storage

Fertilizer complete

pH probe EC probe

Water dilute battery acid

28

fert

igat

ion

v.6agcat

HI 2500MINI CONTROLLER FERTIGATION SYSTEM

customcontrol & injection systems

AUTOMATICALLY CONTROL pHAND ppm IN IRRIGATION WATER

ORDERING INFORMATIONHI 2500 Contact your local HANNArepresentative for more information.

Typical installation diagram shown for representation.Your installation may differ.

Page 29: Hanna Instruments Agricultural Products Catalog 2010

HI 5000 Typical Installation Diagram• Mixing tank, level controller, fertilizer tanks, circulator pump and related plumbing not included.

• Circulation/Irrigation Pump Recommend 0.75HP end-suction centrifugal pump (pump size and power specifications are dependent on greenhouse requirements). Pump MUST be large enough to power injector. (MIN 0.75HP)

29

fertigation

With Great Products, Come Great Results™ v.6agcat

HI 5000MINI FERTIGATION SYSTEM • 0 – 25 GPM flow rate (w/55 gal mix tank) Higher flow rates are obtainable when utilizing a larger mix tank and pump.

• Supplied with 2 isolated electro-valve injectors and 3 fertilizer connections.

• Independent EC and pH control functions (see HI9913 and HI9935 instruction manuals for complete controller specifications).

• Supplied with 3 sets of suction tubing and foot valves for fertilizer connections.

• Supplied with Acid dosing pump connected directly to the system (no hook up required)

• Main input and output can be connected to hose fittings for quick “plug and play” assembly.

• Equipped with a venturi injector… no moving parts!

• Visual flow meter for easy fertilizer flow adjustments

The HI 5000 is an all-in-one, ready to use control system. Compact and versatile, the Mini Fertigatorbrings precision nutrient and acid control to professional grower and advanced home grower alike.

The Mini Fertigator is easy to install and comes completely pre-assembled. To install the unit, simplyattach two pipes and plug into the power cord. No wiring or no assembly!

To inject nutrients, the mini Fertigator uses a venturi so there are no high-maintenance peristalticpumps to worry about. HANNA's included Blackstone pump can handle full-strength acid, so thereis no need to risk an accident with dilution. HANNA's flat-tipped probes are also highly resistant tofouling and clogging.

The automated dosing feature allows growers to optimize growth without spending half the timemeasuring, mixing and dosing. The Mini Fertigator allows growers to set precision dosing duringvegetative and fruiting stages, maximizing harvest and profit

AcidTank

Fertilizer Tanks

Circulation/Irrigation

Pump

To Plants

Ball Valves for Flow Control

55 GallonMixing Tank

Water Supply

Valve

Level Controller

WORKS WITHCIRCULATOR

PUMPS ASSMALL AS .75

HORSEPOWER

Page 30: Hanna Instruments Agricultural Products Catalog 2010

30

fert

igat

ion

v.6agcat

HI 10,000 Series FERTIGATION SYSTEMS FOR IRRIGATION,FERTILIZATION, pH AND EC CONTROL

High Capacity Venturi Injectors.Up to 750 l/h (3.8GPM) of suction.

High speed sole-noid valves.

Dual EC probetechnology.

In-line static mixer High quality circulator pumpstainless steel impeller.

8 bolt flangeconnections foreasy installation.

Wide Range.Flow rate from 5GPM up to ratesexceeding 300GPM.

Emergency shut-off capability.

Electrical box containingredundant fusing andsafety controls.

Fully integrated and dynamic PID controller specifically designedfor green house industry.

Industrialgrade pHelectrode.

Fertigationflow meters.

HI 10,000 Series Overview

• Accurate control —via continuous EC and pH monitoring

• 8 to 300 GPM —flow rate range

• 65 to 75 PSI —operating range

• Bypass system —unit does not interfere with main line flow

• 3 fertilizer injectors and 1 minor or (mild) acid

• Make your own combination fertilizer —Each fertilizer can be set to a specific percent. Ex: Injector #1 (N = 20%), Injector #2 (P = 10%), Injector #3 (K = 20%)

• 10 programs —for various EC and pH set-points and fertilizer percentages

• Save money on fertilizer usage

• Optimize the nutrients to your plants

• Control over 32 valves —Valves can be controlled sequentially, or x 2, x 3 …up to x 8 at once

• Programs can be triggered by time, external switching, and/or flow

• Flow activated —to allow for spot watering, timer adjustable

• Control agitators and filter cleaning

• Alarm Control and Redundant Monitoring

• GSM compatible —for remote monitoring and control from PC

Powerful Features com

plet

egr

eenh

ouse

fert

igat

ion

cont

rol

Page 31: Hanna Instruments Agricultural Products Catalog 2010

31

fertigation

With Great Products, Come Great Results™ v.6agcat

SPECIFICATIONS HI 10,000 CONTROLLER (HEAD UNIT)Range pH : 0.0 to 14.0; EC: 0.0 to 10.0 mS/cm

Resolution 0.1 pH / 0.1 mS/cm

Accuracy (@20°C/68°F) pH: ±0.0546; EC: ±0.078 mS/cm

Typical Inputs2 pH electrodes, 3 conductivity probes, 4 fertilizer tanks, 1 acid tank, 5 tank level

controls, 1 mixing tank level control, 2 differentialpressures, 1 irrigation counter, 1 temporary break, 1 conditional stoppage

Typical Outputs 2 non-consent alarms, up to 32 zone valves, 2 filter flushing, pump, agitator, 4 fertilizer tank electro-valves, 1 pH tank electro-valve

Number of Programs 10

Program Method keypad

Irrigation Capacity 1, 4, 8 and 32 zone valves

Irrigation Control time/volume control, 1 to 6 different timetables per program,

ORDERING INFORMATIONContact your nearest HANNA for more information on how the HI 10,000 can benefit your greenhouse.

CONTROL PANEL

2

3

4

1

5

1. Fertilizer and acid injection indicators (LEDs)

2. Main pump and alarm indicators (LEDs)

3. Multiple zone valve indicators (LEDs)

4. Touch Keypad

5. Backlit LCD

HANNA,a world leader in EC and pH control technology has worked with leading growers to developadvanced system solutions for crops of any type. The HANNA Fertigation System provides precisecontrol of pH and fertilizer injection. Unlike flow driven systems of the past, the HANNA Fertigation System constantly measures the actual EC and pH of the water, allowing the system toadd the precise concentration of fertilizer directly to the irrigation supply. The HANNA System is abypass system which does not limit line flow or pressure. This allows the user to accurately inject fertilizer from 5 GPM up to 300 GPM.

The HI 8000 series controller included with the system has 10 programs that allow the user to setvarious EC and pH values for a variety of plants. Each system allows the injection and mixing of upto 4 fertilizers. If preferred, each fertilizer injector can be set to a specific percent, allowing the userto mix combination fertilizers from basic N - P - K elements, providing a considerable cost savings.The HANNA Fertigation System also controls up to 32 irrigation valves for complete automation ofthe fertigation process.

Pro’s ChoiceHANNA’s Fertigation and pH Control Systemscan be found in a number of notable green-houses throughout the USA: Van WingerdenGreenhouses NJ, Gro-Rite NJ, Van Vugt NJ,Michael’s Greenhouse CT. Additional installa-tions include such greenhouse leaders such asOVW Greenhouse NJ, and De Groot GreenhouseNJ, Van Wingerden Greenhouses WA.

Quality and ServiceThe HANNA systems are above all reliable,durable and require little to no maintenanceand each unit is backed by impeccable trainingand support …just ask our clients!

“We replaced our manual injectors with theHANNA system and are now adding supplemen-tal fertilizers to optimize the nutrients to theplants.

The result is healthier plants and longer shelflife when delivered to our customers”.

MARK KELLYGrowerGrower Direct FarmsCT USA

“Best mums ever since integrating the HANNAsystem”.

MIKE VANDEVREDEGrowerGro RiteLincoln Park, NJ USA

REFERENCES AVAILABLEUPON REQUEST

Page 32: Hanna Instruments Agricultural Products Catalog 2010

32

solu

tion

s

v.6agcat

BOTTLES AND SACHETS

BOTTLES

CODE DESCRIPTION SIZEHI 70300L Electrode Storage Solution 500 mL

HI 70300M Electrode Storage Solution 250 mL

CODE APPLICATION PACKAGE

HI 70000P Rinsing (25) 20 mL sachet

HI 7061L General Purpose 500 mL bottle

HI 7061M General Purpose 250 mL bottle

Electrode Storage SolutionsTo minimize junction clogging and ensure fast response time, always keepthe glass bulb and the junction of your pH electrode moist. Store the electrode with a few drops of HI 70300 in the protective cap.

General Use Cleaning Solutions Clean the liquid junction of your electrodes once a day or at least once aweek to prevent junction clogging and to maintain accuracy. Immerse theelectrode in the proper cleaning solution for at least 15-20 minutes.

Application Specific CleaningHANNA has prepared a complete line of cleaning and disinfection solutions that eliminate impurities and residues left on electrode surfaces when immersed in special samples.

The fresh and easy toopen sachet packageis a practical andideal solution forfield measurements.

CODE DESCRIPTION SIZE

HI 70663L Cleaning Solution for Soil Deposits 500 mL

HI 70663M Cleaning Solution for Soil Deposits 250 mL

HI 70664L Cleaning Solution for Humus Deposits 500 mL

HI 70664M Cleaning Solution for Humus Deposits 250 mL

HI 70670L Cleaning Solution for Salt Deposits 500 mL

HI 70670M Cleaning Solution for Salt Deposits 250 mL

HI 70671L Cleaning and Disinfection Solution for Algae, Fungi and Bacteria 500 mL

HI 70671M Cleaning and Disinfection Solution for Algae, Fungi and Bacteria 250 mL

CODE DESCRIPTION QTY/SIZE

HI 700661P General Purpose Cleaning Solution for Agriculture (25) 20 mL

HI 700663P Cleaning Solution for Soil Deposits (25) 20 mL

HI 700664P Cleaning Solution for Humus Deposits (25) 20 mL

HI 700670P Cleaning Solution for Salt Deposits (25) 20 mL

HI 700671P Cleaning and Disinfection Solution for Algae, Fungi and Bacteria (25) 20 mL

BOTTLES

SACHETS

Don’t Let Your Electrode Dry OutIdeally, pH electrodes should be stored in a storage solution when not inuse. Placing the electrode in a small glass filled with storage solution issuitable. An option for pocket meters is to place a small piece of spongeinto the meter’s cap and pouring storage solution into the cap to wet thesponge. Pouring out the excess solution beforehand, the cap can then beplaced on the meter.

If a storage solution is not available the next best option is to use pH 4.01buffer (pH 7.01 is also suitable to a lesser extent).

Clean Your Electrodes Before UseClean the liquid junction of your electrodes once a day or at least once aweek to prevent junction clogging and to maintain accuracy. Immerse theelectrode in the proper cleaning solution for at least 15-20 minutes.

HANNA offers a wide range of cleaning solutions, for general purpose andspecific applications.

Replace Your Electrode Once a Year, Solutions Once a MonthIf your electrode takes too long to stabilize a reading or readings fluctuatewildly, it is probably time to replace the electrode. 6 months to 1.5 yearsis the typical life span of any pH electrode.

Change your solutions once a month to avoid erroneous calibrations ormeasurements due to age or contamination. Opening a new HANNA sachet guarantees freshness every time.

Solution that is Fresh Every TimeHANNA single-use sachets are a great wayto ensure a fresh solution is used everytime you calibrate. Just tear open thepacket and insert the electrode. Theselight-tight sachets are also ideal fortesters—they fit right in!

TIPS FOR THE MOST ACCURATEMEASUREMENTS

Page 33: Hanna Instruments Agricultural Products Catalog 2010

33

solutions

With Great Products, Come Great Results™ v.6agcat

pH Buffer SolutionsHANNA buffer solutions are prepared using precise formulas and are stan-dardized with a pH electrode and meter calibrated with NIST standards.

CODE pH VALUE @25°C SIZE PACKAGE

HI 7004L 4.01 500 mL 1 bottle

HI 7004M 4.01 250 mL 1 bottle

HI 70004P 4.01 20 mL 25 sachets

HI 7007L 7.01 500 mL 1 bottle

HI 7007M 7.01 230 mL 1 bottle

HI 70007P 7.01 20 mL 25 sachets

HI 7010L 10.01 500 mL 1 bottle

HI 7010M 10.01 250 mL 1 bottle

HI 70010P 10.01 20 mL 25 sachets

BOTTLES AND SACHETS

CODE DESCRIPTION SIZE

HI 7020L ORP Test Solution at 200/275 mV (@20°C) 500 mL

HI 7020M ORP Test Solution at 200/275 mV (@20°C) 250 mL

HI 7021L ORP Test Solution at 240 mV (@20°C) 500 mL

HI 7021M ORP Test Solution at 240 mV (@20°C) 250 mL

HI 7022L ORP Test Solution at 470 mV (@20°C) 500 mL

HI 7022M ORP Test Solution at 470 mV (@20°C) 250 mL

HI 7091L Reducing Pretreatment Solution 500 mL

HI 7091M Reducing Pretreatment Solution 250 mL

HI 7092L Oxidizing Pretreatment Solution 500 mL

HI 7092M Oxidizing Pretreatment Solution 250 mL

ORP Test and Pretreatment solutionsORP test solutions allow users to test the precision of ORP electrodes. Forexample, by immersing the electrode in HI 7020 solution, readings shouldfall within the 200 to 275 mV range (@20°C/68°F).

If the reading is outside the indicated interval, clean and condition yourORP electrode in HANNA pretreatment solution.

BOTTLES

CODE DESCRIPTION SIZE

HI 7051M Soil Sample Preparation Solution 250 mL

HI 7051L Soil Sample Preparation Solution 500 mL

Sample Preparation SolutionsBOTTLES

BOTTLES

CODE DESCRIPTION SIZE

HI 7040M Zero oxygen solution 250 mL

HI 7040L Zero oxygen solution 500 mL

HI 7041S Electrolyte solution for polarographic DO probes 30 mL

HI 7042S Electrolyte solution for galvanic probes 30 mL

Dissolved Oxygen Solutions

Conductivity Calibration Solutions84 μS/cm solution makes it possible to calibrate instruments with a conductivity scale of up to 200 μS/cm.

The 1413 μS/cm solution is best suited for general use.

5000 μS/cm solution s ideal for those applications that need to achievehigher reading accuracies in a conductivity scale between 2000 μS/cm and10000 μS/cm.

12880 μS/cm (12.88 mS/cm) solution is widely used to assure properperformance of conductivity meters with a scale higher than 10 mS/cm.

8000 μS/cm solution is needed for the proper calibration of instrumen-tation used to measure high conductivity samples.

111800 μS/cm solution is useful to calibrate instrumentation used to meas-ure samples with conductivity higher than 100 mS/cm (100,000 μS/cm).

CODE EC VALUE @25°C SIZE PACKAGE

HI 7033L 84 μS/cm (μmho/cm) 500 mL 1 bottle

HI 7033M 84 μS/cm (μmho/cm) 250 mL 1 bottle

HI 70033P 84 μS/cm (μmho/cm) 20 mL 25 sachets

HI 7031/1G 1413 μS/cm (μmho/cm) 1 Gallon (3.78 L) 1 bottle

HI 7031L 1413 μS/cm (μmho/cm) 500 mL 1 bottle

HI 7031M 1413 μS/cm (μmho/cm) 250 mL 1 bottle

HI 70031P 1413 μS/cm (μmho/cm) 20 mL 25 sachets

HI 7039L 5000 μS/cm (μmho/cm) 500 mL 1 bottle

HI 7039M 5000 μS/cm (μmho/cm) 250 mL 1 bottle

HI 70039P 5000 μS/cm (μmho/cm) 20 mL 25 sachets

HI 7030/1G 12880 μS/cm (μmho/cm) 1 Gallon (3.78 L) 1 bottle

HI 7030L 12880 μS/cm (μmho/cm) 500 mL 1 bottle

HI 7030M 12880 μS/cm (μmho/cm) 250 mL 1 bottle

HI 70030P 12880 μS/cm (μmho/cm) 20 mL 25 sachets

HI 7034L 80000 μS/cm (μmho/cm) 500 mL 1 bottle

HI 7034M 80000 μS/cm (μmho/cm) 250 mL 1 bottle

HI 7035L 111800 μS/cm (μmho/cm) 500 mL 1 bottle

HI 7035M 111800 μS/cm (μmho/cm) 250 mL 1 bottle

BOTTLES AND SACHETS

TDS SolutionsHANNA is one of the few producers to offer TDS calibration solutions foragriculture applications with packages from 20 to 500 mL.

CODE TDS VALUE @25°C SIZE PACKAGE

HI 7032L 1382 ppm (mg/L) 500 mL 1 bottle

HI 7032M 1382 ppm (mg/L) 250 mL 1 bottle

HI 70032P 1382 ppm (mg/L) 20 mL 25 sachets

HI 7036L 12.41 ppt (g/L) 500 mL 1 bottle

HI 7036M 12.41 ppt (g/L) 250 mL 1 bottle

HI 70038P 6.44 ppt (g/L) 20 mL 25 sachets

HI 70080P 800 ppm (mg/L) 20 mL 25 sachets

HI 70442L* 1500 ppm (mg/L) 500 mL 1 bottle

HI 70442M* 1500 ppm (mg/L) 250 mL 1 bottle

HI 70442P* 1500 ppm (mg/L) 20 mL 25 sachets

BOTTLES AND SACHETS

*TDS conversion factor 4-4-2: 0.65 ppm = 1 μS/cm (approximately)

Page 34: Hanna Instruments Agricultural Products Catalog 2010

34

guid

es

v.6agcat

First Step For New MetersFor new meters soak in tap water for 30 min-utes to re-hydrate pH bulb and to clean off anydeposits (Fig. 1).

Turning OnPush left MODE button and release.

The display will scroll through battery and dis-play function: pH,mS or ppt

pH FunctionPress the HOLD button to move to differentfunctions.

Leave meter in pH function.

Entering Calibration ModePress and hold the left MODE button. The dis-play will cycle through the OFF screen then dis-play CAL. Release the button when CAL appearson the display (Fig. 2).

The display will next read 7.01 USE. This meansplace the tester in pH 7.01 solution (Fig. 3).

When the display reads 4.01 USE, remove thetester from the pH 7.01 solution and place thetester in pH 4.01 solution.

Calibration CompleteThe tester will display Okay momentarily thenread 4.0, or 3.9.

The tester is now calibrated

HOW TO CALIBRATE HI 98129 AND HI 98130COMBO TESTERS

SOIL TESTING

MethodsSlurry: Mixing distilled water with soil media.Several dilution formulas 1:1, 2:1, 3:1

The most common slurry is 2:1

Pour thru: Pouring water through the media and measuring the leachate.

Advantages of EachMethodSlurry: Most cultural guide recommendations are based on this method.

Pour thru: good for testing small cells (plugtrays) and large nursery pots.

Different methods give different readings.

Fig. 1

Fig. 3

Fig. 2 2:1

How to Perform a 2:1 Slurry

Formula: 2 parts distilled water, 1 part media.

Mix the water and media together then wait for15 minutes to allow for minerals to dissolve inthe water.

Place meter in slurry and measure.

“Zero” theChecker®HC with

your unreactedwater sample

Add reagent to yourwater sample

Press the button andread the results. it’s

that easy!

Place the vial intoyour Checker®HC

MEASURING SAMPLES WITH THECHECKER®HC

Page 35: Hanna Instruments Agricultural Products Catalog 2010

35

limited w

arranty

With Great Products, Come Great Results™ v.6agcat

HANNA products are manufactured in our ISO 9001:2000 facilities, meeting the highest quality standards in the industry. HANNA’s high standards alsoapply should a product be returned due to defects in material or workmanship. Our extensive warranty extends up to five years on some products.

Limitations: Warranted products may be returned for repair or replacement only at the discretion of HANNA. In some circumstances, remedy may constitute refund for the price paid for the product.

The warranty period commences from the original date of sale to the user or a maximum of 18 months from factory ship date. Warranty is valid only whenthe product is used under normal conditions and in accordance with operating limitations and prescribed maintenance procedures. The express warrantystated previously is the only express warranty given by HANNA to the end-user buyer. HANNA expressly disclaims any warranties implied by law, includingbut not limited to warranty of merchantability of fitness for a particular purpose. HANNA shall not be liable for any individual or consequential damages ofany kind for breach of any warranty, negligence, on the basis of strict liability or otherwise. HANNA’s warranty periods differ across our range of instru-mentation, please visit us on the web at: www.hannainst.com or contact your local HANNA representative for specific warranty information.

Instrument Service:Warranty and non-warranty service, replacement, recalibration and repairs are performed by factory trained service technicians at one of HANNA’s TechnicalService Centers worldwide. All items must have a Return Goods Authorization (RGA) number that can be obtained by contacting the HANNA TechnicalService Department. The RGA number should be clearly marked on the outside of the box and the unit shipped prepaid and insured. Any product notbearing an RGA number will be refused. All products returned for warranty repair or replacement MUST be preceded or accompanied with proof of purchase,such as the original invoice or packing slip. Under special circumstances it may be deemed necessary by HANNA to issue a Return In Advance (RIA). In suchcases, the defective materials must be returned to HANNA within 30 days. Materials not returned within 30 days become chargeable. Materials must bepacked properly to avoid damage during transport, which would render the warranty null and void. The sender is responsible for expediting any damageclaims placed against the carrier.

In most cases, a flat minimum service charge applies to non-warranty repairs or recalibration. Please contact your local HANNA Technical Service Department for current rates. Any materials returned for repair which are considered non-warranty may be serviced at hourly cost (excluding parts) following subsequent notification and approval of such.

Limited Warranty

Returning Merchandise:Should an instance occur when a product may need to be returned for exchange or credit, or should a discrepancy occur in a packing slip, HANNA mustbe contacted to obtain a Return Goods Authorization Number (RGA). Please follow these steps:

1. Within 30 days of receipt of merchandise call HANNA’s Technical Service Department to obtain a Return Goods Authorization Number.2. HANNA will issue a Return Goods Authorization Number.3. The number must be clearly marked on the outside of the package being returned. Shipments not bearing a Return Goods

Authorization Number will be refused.4. Credit returns may be subject to a 25% restocking fee.

Terms and ConditionsReturn shipments must meet the following requirements to be accepted for credit:

1. Products must be returned in the original packaging with labeling not defaced. All items returned will be inspected for credit worthiness. Credit will only be issued for product returned in like-new condition. No credit will be issued for product, which is not received in like-new condition.

2. All freight charges are the responsibility of the customer.3. All chemicals and reagents being returned must be packaged in accordance with the laws and regulations of the governing country.

Only unopened chemicals and reagents may be returned.

Limited Warranty, Return andExchange

Product Return and Exchange

HANNA instruments® reserves the right to change or modify the design of its products at any time without advance notice.

Page 36: Hanna Instruments Agricultural Products Catalog 2010

Visit us on the web for additional product information, contacts and distributor information

ISO

900

1:20

00

CERT

IFIE

D

P/L

AG

CAT

V6_

US

A 1.

0 P

RIN

TED

IN U

SA

HANNA Instruments, USAHighland Industrial Park584 Park East Drive, Woonsocket, Rhode Island 02895

phone: (800) 426-6287fax: (401) [email protected]