Haier air conditioner Edition: 1.0-070801
- 1 -
DomesticAir conditioner
CAUTION READ THIS MANUAL
CAREFULLY TO
DIAGNOSE TROUBLE
CORRECTLY BEFORE
OFFERING SERVICE.
THIS MANUAL IS USED
BY QUALIFIED
APPLIANCE
TECHNICIANS ONLY.
HAIER DOES NOT
ASSUME ANY
RESPONSIBILITY FOR
PROPERTY DAMAGE
OR PERSONAL INJURY
FOR IMPROPER
SERVICE
PROCEDURES DONE
BY ONE UNQUALIFIED
PERSON.
HSU-09HC03/R2(DB)HSU-12HC03/R2(DB)HSU-18HC03/R2(DB)HSU-22HC03/R2(DB)
Haier air conditioner Edition: 1.0-070801
- 2 -
CONTENTS
1. GENERAL INFORMATION...............................................................3
2. SPECIFICATION...............................................................................5
3. ELECTRICAL CONTROL..................................................................8
4. THERMISTER RESISTANCE CHART.............................................26
5. TROUBLE SHOOTING....................................................................35
6. PERFORMANCE CURVES DIAGRAM...........................................486.1 High drop and long pipe capacity modification curves……………………….........486.2.1 Cooling capacity-temperature curves………………………………….................496.2.2 Heating capacity-temperature curves……………………………………….........536.3 Air outlet temp.-ambient temperature curves………………………………….........576.4.1 Cooling discharge pressure curves...................................................................616.4.2 Cooling suction pressure curves.......................................................................656.4.3 Heating discharge pressure curves...................................................................696.4.4 Heating suction pressure curves.......................................................................736.5 Sensible cooling value-temperature curves.........................................................776.6 Power consumption-temperature curves.............................................................816.7 Noise curves........................................................................................................856.8Compressor performance curves……………………………………………….........87
7. WIRING DIAGRAM..........................................................................89
8. SCHEMATIC DIAGRAM OF PCB....................................................99
9. INSTALLATION................................................................................104
Haier air conditioner Edition: 1.0-070801
- 3 -
1. General information This Service Manual describes the operation, disassembly, troubleshooting, and repair of Haier Room Air Conditioners, etc. It is intended for use by authorized services that troubleshoot and repair these units. It is assumed that users of this manual are familiar with the use of tools and equipment used to troubleshoot and repair electrical, mechanical, and refrigeration systems; and understand the terminology used to describe and discuss them. Haier urges you read and follow all safety precautions and warnings contained in this manual. Failure to comply with safety information may result in severe personal injury or death.
Related Publications
This is a base service manual, covering a range of similar models. It is intended to be used in conjunction with the Parts Manual and Technical Sheet covering specific model being serviced.
NOTE: General Precautions and Warnings
WARNING
To avoid risk of personal injury or death due to electrical shock, disconnect electrical power to unit before attempting to service the unit.
WARNING
To avoid risk of personal injury or death due to electrical shock, DO NOT, under any circumstances, alter the grounding plug .Air conditioner must be grounded at all times. Do not remove warning tag from power cord. If a two-prong (non-grounding) wall receptacle is encountered, contact a qualified electrician and have the receptacle replaced with a properly grounder wall receptacle in accordance with the National Electrical Code.
WARNING
To avoid risk of heat exposure, which may cause death or severe illness, air conditioner must be monitored when malfunctions or shuts down.
WARNING
To avoid risk of personal injury or death due to electrical shock, grounding wires and wires colored like grounding wires are NOT to be used as current carrying conductors. The standard accepted color coding for ground wires is green or green with a yellow stripe. Electrical components such as the compressor and fan motor are grounded through an individual wire attached to the electrical component and to another part of the air conditioner. Grounding wires should not to be removed from individual components while servicing, unless the component is to be removed and replaced. It is extremely important to replace all removed grounding wires before completing service.
Haier air conditioner Edition: 1.0-070801
- 4 -
HSU-09HC03/R2(DB) HSU-12HC03/R2(DB) HSU-18HC03/R2(DB)
HSU-22HC03/R2(DB)
HSU-09HC03/R2(DB) HSU-12HC03/R2(DB) HSU-18HC03/R2(DB) HSU-22HC03/R2(DB)
Product Features Photo catalyst Healthy negative ion Left &right airflow Bacteria-killing medium Intelligent airflow Entire auto mode
Haier air conditioner Edition: 1.0-070801
- 5 -
2. Specification Item Unit HSU-09HC03/R2(DB) HSU-12HC03/R2(DB)
Power PH, V, Hz 1 230 50 1 230 50Climate Type T1 T1
Cooling Capacity (W) 2600W 3500W Rated Power (W) 680W 1000W Rated Current (A) 3.0A 4.9A Max Power (W) 1150W 1550W Max Current (A) 4.2A 7.0A
Cooling
EER (W/W) 3.82 3.50 Heating Capacity(W) 3400W 4200W Rated Power (W) 930W 1250W Rated Current (A) 4.2A 5.6A Max Power (W) 1350W 1520W Max Current (A) 4.5A 6.9A
Heating
COP (W/W) 3.66 3.36 Starting Current (A) 4.0 Operating temp. range (A) 16~43 16~43Class of electric Shock Protection I I Class of Water Proof IP24 IP24 Remote Controller Model YR-H79 YR-H79 Moisture Removal (10-3m3/h) 1.2x10-3 1.5x10-3 Max. pressure at warm side (Mpa) 4.15 4.15
Length (mm) 580±5 580±5 Drain Hose
Diameter (mm) 25.5±2 25.5±2H (rpm) 1150 1250 M (rpm) 1050 1150 Indoor fan Velocity L (rpm) 950 1000
Outdoor fan Velocity H (rpm) 800 800
Air Volume (High) Indoor(m3)
490 600
Manufacture TOSHIBA TOSHIBA Type DA89X1C-20FZ DA108X1C-20FZ3
Compressor Compressor Oil Charge (ml)
370cc 480cc
Type R410A R410A Net Charge (g) 960 1140
Refrigerant Charge if over standard pipe length
20g/m 20g/m
Liquid pipe Diameter (mm)
6.35 6.35 Refrigerant Pipe
Gas pipe Diameter (mm)
9.52 9.52
Haier air conditioner Edition: 1.0-070801
- 6 -
Standard length (m) 4m 4m Max length (m) 15m 15m Indoor (H/M/L) (dBA) 44/41/38 45/42/39
Noise Level Outdoor (dBA) 54 52
Net (kg) 8.8 10.6 Indoor
Gross (kg) 10.6 12.6 Net (kg) 34 37.5 Weight
Outdoor Gross (kg)
37 40.5
Net (mm) 795*265*182 938*265*182 Indoor Package
(mm)863*330*275 1013*330*275
Net (mm) 783*543*255 783*643*255 Dimension
Outdoor Package(mm)
930*614*340 930*714*340
Haier air conditioner Edition: 1.0-070801
- 7 -
Item Unit HSU-18HC03/R2(DB) HSU-22HC03/R2(DB)
Power PH, V, Hz 1 230 50 1 230 50Climate Type T1 T1
Cooling Capacity (W) 5000W 6000W Rated Power (W) 1700W 2040W Rated Current (A) 7.5A 9.2A Max Power (W) 2000W 2500W Max Current (A) 9.5A 11.5A
Cooling
EER (W/W) 3.94 2.94 Heating Capacity(W) 5600W 6600W Rated Power (W) 1830W 2160W Rated Current (A) 8.0A 9.7A Max Power (W) 2200W 2750W Max Current (A) 9.5A 12.5A
Heating
COP (W/W) 3.06 3.06 Starting Current (A) 7.5 Operating temp. range (A) 16~43 16~43Class of electric Shock Protection I I Class of Water Proof IP24 IP24 Remote Controller Model YR-H79 YR-H79 Moisture Removal (10-3m3/h) 2.0x10-3 2.5x10-3 Max. pressure at warm side (Mpa) 4.15 4.15
Length (mm) 580±5 580±5 Drain Hose
Diameter (mm) 25.5±2 25.5±2H (rpm) 1350 1350 M (rpm) 1150 1150 Indoor fan Velocity L (rpm) 1000 950
Outdoor fan Velocity H (rpm) 830 830
Air Volume (High) Indoor(m3)
670 700
Manufacture PANASONIC PANASONIC Type 5CS130XCC03 5CS160XAA23
Compressor Compressor Oil Charge (ml)
480cc 600cc
Type R410A R410A Net Charge (g) 900 1900
Refrigerant Charge if over standard pipe length
20g/m 20g/m
Liquid pipe Diameter (mm)
6.35 6.35
Gas pipe Diameter (mm)
12.7 12.7
Refrigerant Pipe
Haier air conditioner Edition: 1.0-070801
- 8 -
Standard length (m) 4m 4m Max length (m) 15m 15m Indoor (H/M/L) (dBA) 46/43/41 48/45/42
Noise Level Outdoor (dBA) 57 58
Net (kg) 17 17 Indoor
Gross (kg) 20 20 Net (kg) 43 54.5 Weight
Outdoor Gross (kg)
48 58.5
Net (mm) 938*265*182 1155*308*224 Indoor Package
(mm)1013*333*275 1225*310*371
Net (mm) 820*310*682 865*335*732 Dimension
Outdoor Package(mm)
949×406×745 995*420*815
3. Electrical control
. Application Range This specification use for HSU-09/12/18/22HC03/R2 DB frequency conversion air condition are manufactured by Haier air condition parent company. "Setting value" (express in parameter) in this specification means is a parameter that is stored in EEPROM. Refer to [EEPROM parameter table].
Indoor Unit
Haier air conditioner Edition: 1.0-070801
- 9-
Temperature Adjusting function 2.1This function will decide the outdoor unit’s running speed according to the indoor temperature and the set temperature. Control the indoor blower fan according to the need for temperature adjusting when the wind rate is automatic.Control the indoor blower fan according to the disc-tube temperature when it’s running for heating.
2.1.1 Indoor environment temperature sensor specification Under the conditions of short circuit or open circuit, the indicative light will flash an alarm and the indoor blower fan stops. When it returns to normal conditions, the operation will come back to normal.
Short circuit Temperature: over 126 . Sixteen scales: over F8H. Resistance value: below 0.65 K.
Normal temperature Temperature: 25 . Sixteen scale: 40H Resistance value: 23K.
DisconnectionTemperature: below minus 31 . Sixteen scale: below 08H. Resistance value: below 620K. Voltage: below 0.15 V B index=4200 R (25 ) =23K
2.1.2 The specification of indoor environment pipe temperature sensor
2.1.3 During the time when the heat running starts and indoor blower fan stops or when the warm boot starts and within 30 seconds after the indoor blower fan starts, the resistance value for indoor environment temperature sensor will be neglected.
2.2 The frequency kept when the frequency rises.
When the operation enters into the work mode, in order to insure the full oil-returning, some frequency should be kept for some time.
Indication time Indication frequency
Cooling & moisture removing
Heating Heating & Frost removing
Frequency kept
60 seconds 60 seconds 30 seconds 58 Hz
When the unit is switched on and the forcible running is over, the temperature level control starts.
2.3 Modify the set temperature
Haier air conditioner Edition: 1.0-070801
- 10 -
The set temperature can be modified according to the unit’s operation mode, wind volume or whether it is under forceful running condition.
The modification of wind volume is only limited within the switch between weak and medium of wind volume when it is under heating mode.
Modification index table for set temperature
Mode Content of modification Modified variable Modified parameter
Operation mode modification ETBL0 4.67Forceful operation modification ETBL1 6
Weak wind volume modification ETBL2 4.67
Heating
Medium wind volume modification
ETBL3 4.67
Operation mode modification ETBL4 -0.33Cooling & moistureremoving
Forceful operation modification ETBL5 -4
2.4 temperature level control
2.4.1 Deviation Work out the deviation of temperature level as follows:
In heating mode: E = (Remote-control set temperature+ modified value)-room temperature
In cooling & moisture removing mode: E = room temperature -(Remote-control set temperature + modified value)
2.4.2 Compressor OFF E is minus and |E|> T
Heating Cooling
T TCHAHL 0.67 TCHACL 0.33 After T changes TCHAHH 0.67 TCHACH 1 condition for Tchanges
E 3.0 when operation starts
The compressor stops after 120 seconds of continuous detection
When the operation starts, according to the table above, the unit will operate according to the after-the- T-change parameters before the compressor stops for the first time.
From the time the compressor stops to the time it starts again, the operation will follow the T (except the moisture removing mode)
When the operation starts and the operation modes change (except when the idle mode is over) and
Haier air conditioner Edition: 1.0-070801
- 11 -
the deviation is bigger than – T, the compressor starts.
When the compressor is working and the remote-controller set temperature falls below – T, the compressor stops.
2.4.3 Compressor operation When the compressor is kept idle for 3 minutes, the deviation E will be higher than - T+0.67 and the compressor will start working. 2.4.4 DASH operation When the operation starts or the operation mode changes (except when the compressor is switched on after being off), the compressor is on and the indicated maximum frequency should be as follows: Cooling deviation to zero Moisture removing deviation to level G Heating deviation to level F There will be no DASH operation under trial operation, emergency operation and silent operation modes.
2.4.5 Temperature adjusting of different levels. (DASH operation conditions under different modes) cooling/ moisture removing /heating /level / cooling / moisture removing /heating /Value E/<120 seconds/ 3-minute idle mode /compressor restart
2.4.6 Frequencies for different levels Within different levels, the indicated frequencies are(the frequency the indoor unit transmits to the outdoor unit) as follows
Under the cooling & moisture-removing mode, level A and B have the same frequency. Under the silent mode, levels A-E have the same frequency with level F
Haier air conditioner Edition: 1.0-070801
- 12 -
Indicated frequency Frequency range
Temperature change level
Heating FQHOT [0—7] 36-80Hz A—H Silentheating
FQSHOT [0—2] 36-72Hz F—H
Moistureremoving
FQDRY [0—7] 36-80Hz B—H
Cooling FQCOOL [0—7] 36-80Hz B—H Silentcooling
FQSCOOL [0—2] 36-64Hz F—H
The maximum frequency value refers to the max value listed above. The maximum and minimum values for cooling and heating are the maximum and minimum values for correspondent items.
2.4.7 Controlled frequency for the same level The indicated frequency when a level remains unchanged after the compressor operates with the same frequency for 3 minutes.
The timing will start again when there is a different frequency input. If the temperature level remains unchanged for 3 minutes, the indicated frequency will change again (add FQUPH or FQUPL)
Controlling form for the same level
Levels of temperature change
A B C D E F G H
Heating FQUP (2Hz) FQUP (2Hz) FQUP (2Hz) FQUP (1Hz) FQUP (1Hz)
Cooling&moistureremoving
FQUP (2Hz) FQUP (2Hz) FQUP (2Hz) FQUP (1Hz) FQUP (1Hz)
FQUPH 2Hz FQUPL 1Hz
2.4.8 Select the wind volume when it is set automatic When the wind volume is automatic, it can be switched between strong, medium and weak according to the temperature adjusting levels. Wind volume under the automatic wind volume mode
Haier air conditioner Edition: 1.0-070801
- 13 -
Temperature adjusting levels
A B C D E F G H I
Heating Strong Strong Strong Strong Strong Medium Weak Weak SLO
cooling Strong Strong Strong Medium Medium Weak Weak Weak
Moistureremoving
Strong Medium Medium Medium Weak Weak SLO SLO
2.5 Frost removing
Under the intensive-running protection mode, the protection control will be in priority The compressor does not stop Under heating operation mode, the outdoor unit sends a frost-removing signal (I21=10) and the indoor unit will start the frost-removing control until the outdoor unit transmits the signal to end the frost-removing. Then the indoor unit starts the heating operation, indication levels and wind volume control will operate following the heating temperature levels.
2.6 Wind volume limit
When the compressor is working and the max setting for indoor blower fan is medium or weak, the upper limit of indicated frequency is as follows: Frequency control form for wind volume
Limited frequency variables
Limited frequency
Medium wind volume FQLIMMD 80Hz Weak wind volume FQLIMLO 52Hz
Limited frequency for up/down health wind
FUPHEAL 40Hz
When judging the conditions for frequency limit under the heating mode, first judge if the unit has been set to weak wind volume or health wind modes. If it has been set to one or both of the modes, then follow the table below for the limit modification.
Outdoor temperature condition
Indicated frequency
011(Below 20 ) Limited frequency for weak or health wind
010(15-20 ) Limited frequency for weak or health wind +FUPHEA1
10
001(10-15 ) Limited frequency for weak or health wind+ FUPHEA2
15
000(below10 ) Normal frequency
Haier air conditioner Edition: 1.0-070801
- 14 -
Indoor blower fan control
When the wind volume is manually medium, the running speed is (strong + weak)/2.
When it is automatically medium, the running speed is (strong automatic+ weak automatic)/2(not counted if it is not up to 10rpm)
3.1heat running
3.1.1 Warm boot When the heat running starts or the frost removing ends and the compressor starts again, in order to avoid cold wind, warm boot wind volume control should be done. Heat exchange temperature
THHOT337.0THHOT235.2 THHOT125.2 4 minutes THHOTR16
Stop weak setting weak stop
To control the indoor blower fan as shown in the table above according to the heat exchange temperature
When the heat exchange temperature rises to the level between THHOT1 and THHOT2 and even after 4 minutes it cannot reach the level between THHOT2 and THHOT3, enter into the next level without referring to the heat exchange temperature.
The blower fan stops when the heat exchange temperature is below 25The blower fan is working slightly weak when the heat exchange temperature is above 25 and below 35
The blower fan is working weak if the he heat exchange temperature remains 35 for less than 4 minutes.
The blower fan works as set if the he heat exchange temperature remains 35 for more than 4 minutesThe blower fan works as set if the he heat exchange temperature remains above 37
slightlyweak
slightlyweak
Haier air conditioner Edition: 1.0-070801
- 15 -
3.1.2 When the compressor stops and remains idle for 3 minutes 20 seconds after the compressor stops, the wind volume is weak (switching to SSLO in silent running mode) and then slightly weak. If the compressor stops when the heat running starts, the wind volume is weak
3.1.3 Restart of the compressor The wind volume is set by the remote-controller after the warm boot. .select the wind volume by the temperature in the automatic wind volume modeRefer to the temperature level control function
3.1.4 Frost-removing operation The blower stops after 20 seconds When receiving the I21=11 signal from the outdoor unit in the heat frost-removing mode, warm boot will be done according to the hear exchange sensor. The wind volume control is the same with 3.1.1 When the frost-removing process if over, if the compressor is on, the wind volume control will be warm-booted; if the compressor if switched off, the wind volume will be weak.
3.2 cooling running
The wind volume can be set to strong, medium and weak. Automatic wind volume function will decide the wind volume according to the temperature
3.3 Moisture removing running
3.3.1 Compressor off, idle mode for 3 minutes The blower fan stops as the compressor stops The operation is weak after 3 minutes’ idle mode After stand by for 3 minutes, the compressor is on.
3.3.2 Compressors on The compressor operates as the set wind volume when the wind volume is set to be strong, medium or weakThe wind volume is decided according to the temperature adjusting when the wind volume is set to be automatic.
Picture 3.4 Moisture removing running
Level H 3minutes idle mode Compressor OFF
Setting slightly weak OFF weak weak setting
Haier air conditioner Edition: 1.0-070801
- 16 -
Powerful running
Powerful running for 15 minutes The running stops or ends the powerful running after 15 minutes The mode switch ends the powerful running Enter into the silent mode, normal running mode or timed switching on mode to end the powerful running When in automatic mode, there are powerful and silent functions for your choice. When the main unit is in cooling mode, it operates with powerful cooling or silent cooling. When the main unit is in heating mode, it operates with powerful heating or silent heating. When the main unit is in wind-sending mode, there are no powerful or silent modes.
4.1 Powerful heating Change the set temperature. With temperature adjusting function The wind volume is the automatic medium When in frost removing mode, the outdoor unit does not accept the communication signal for powerful running After 15 minutes of powerful running, the compressor can not be off within 10 minutes
4.2 Powerful cooling Change the set temperature. With temperature adjusting function The wind volume is the automatic strong After the compressor starts, there will be no low-intense running protection within 3 minutes
4.3 There is no powerful mode for wind-sending and moisture removing
Silent running Send the silent running signal to the outdoor unit
5.1 Silent hearing The wind volume is SSLO after the compressor is on The wind volume will be kept SSLO within 20 seconds after the compressor stops and then changes to weak
5.2 Silent cooling The wind volume is SSLO
5.3 There is no silent mode for moisture removing and wind-sending.
Air cleaning If the blower fan starts working after receiving the remote-control order, the aion generator starts working and sends out ions. The ion generator stops as the blower fan stops.
Haier air conditioner Edition: 1.0-070801
- 17 -
When the ion generator is OFF and the air cleaning function is on, the blower fan starts running and the ion generator starts working again.
Timed running Set the time duration according to the time difference between the clock for timing and the current clockIn timing mode, the display panel will flash the light at fixed times
7.1 Timed OFF When this function is set, operation modes on the panel display will not change. The timing icon will show and the operation stops when the set time comes.
7.2 Timed ON When this function is on, the panel display will only display a question mark. The unit will operate as the set mode when the time comes.
7.3 Timed ON/OFF The unit will start operating or stop according to the order of your setting.
Sleeping Running 8.1When under the mode of cooling or moisture removing, the set temperature will rise by 1 after 1 hour and another 1 after the next hour. 6 more hours later the operation stops.
8.2Under the heating mode, the set temperature will fall by 2 every 1 hour within the first two hours. It will rise by 1 after another 3 hours and stop after running for 3 hours.
8.3If the indoor blower fan is set to be strong wind before setting the sleeping running, it will be medium wind after setting the sleeping running. If the indoor blower fan is set to be medium wind before setting the sleeping running, it will be weak wind after setting the sleeping running. If the indoor blower fan is set to be weak wind before setting the sleeping running, the running speed of the blower will not change.
Automatic running
9.1 Automatic running mode Under this mode, the MCU will choose the work mode according to the room temperature so as to keep the set temperature (set 23 for heating mode and 26 for cooling mode)
When the unit is powered on for the first time and the room temperature is equal to or below 23 , it
Haier air conditioner Edition: 1.0-070801
- 18 -
will start the heating mode or the cooling mode when the room temperature is higher than 23
Enter into the heating mode and follow the heating process (supposed temperature 23 ). When the temperature is high enough to stop the compressor, the compressor stops and there will 3 minutes of idle mode. If the compressor senses the incoming wind temperature is higher than 23 after it stops for 15 minutes, the unit will switch to cooling mode. Otherwise it will keep the heating mode.
Enter into the cooling mode and follow the cooling process (supposed temperature 26 ).Compensation temperature difference will be cancelled automatically. When the temperature is high enough to stop the compressor, the compressor stops and there will be 3 minutes for idle mode. If the If the compressor senses the incoming wind temperature is equal to or below 23 after it stops for 15 minutes, the unit will switch to heating mode. The compensation temperature will be added automatically. Otherwise it will keep the cooling mode. When the unit switches from other modes to automatic mode, if the work state changes (judge first and then work), there will be 3 minutes for idle mode. Ant then the temperature will change to the judged level according to the incoming wind temperature.
Trial running
Haier air conditioner Edition: 1.0-070801
- 19 -
The indicated frequency for trial running is 58Hz, wind volume is strong. The trial running will last for 30 minutes and then the unit will be powered off. The unit will exit the trial running if it receives any remote-control signal during the trial running period. There is no low-intense running protection.
Low Work-intense protection control Specification for heat-exchange temperature sensor B fixed number=3700 R(25 )= 10KUnder the cooling /moisture removing modes, the low work-intense protection will be carried out according to the heat-exchange temperatures as shown in the table below. Low Work-intense protection control Picture 11.1 Heat-exchange temperature THLHEATBL3 THLHEATBL2 THLHEATBL1 THLHEATBL0
Indicationlevel Normal level2 level 1 stop level 1 level 2
normal
Low Work-intense protection control will be neglected in the trial running. Low Work-intense protection control will be cancelled for 3 minutes temporarily after the powerful cooling starts for 1 minute (THLH[3 2 1 0]= 7 4.6 2.2 -0.5 )
High Work-intense protection control
Under the heating mode, the high work-intense protection will be carried out according to the heat-exchange temperatures as shown in the table below.
High Work-intense protection control:
Haier air conditioner Edition: 1.0-070801
- 20 -
Heat-exchange temperature frequency values when the high work-intense starts THHEAT6 74.7 THHEAT5 70.3 THHEAT4 65.1 THHEAT3 62.2 THHEAT2 52.9 THHEAT1 51.6 THHEAT0 47.1
Indicatedfrequency
C D E D C B A B C D E Normal idle mode stop
High Work-intense protection High Work-intense protection alarm
High Work-intense protection alarm will start if there are two times of high work-intense protection within 30 minutes.
If the heat-exchange temperature does not reach THHEAT [2], it will resume to the normal temperature level control
The smaller one of the high work-intense frequency and level frequency will be the operation data.
1. EEPROM control EEPROM is wrong when the EEPROM parameter sum does not accord with the check sum after the outdoor unit is powered on. The outdoor unit EEPROM is wrong will be displayed when the indoor unit receives wrong EEPROM signals from the outdoor unit. In this case the control and emergency operation are not allowed. Unplug the unit to shoot the problem.
. Special functions 1. Power failure compensation
a. To enter into the function please press the sleep key 10 times with 4 beeps in 7 seconds and store the current state in the EEPROM of the indoor unit.
b. The indoor unit operates as follows when under the power failure compensation mode. Remote-control the emergency signal. The indoor unit operates as the remote-control and the emergency setting and store the current state in the EEPROM in the indoor unit.
The main unit operates as the set state on the display panel and stores the state in the EEPROM. Under the power failure compensation mode, unplug and plug again, the main unit will send the signals for current operation and power failure compensation to the indoor unit panel.
Haier air conditioner Edition: 1.0-070801
1
a. Press the sleep key for 10 times with 2 beeps in 7 seconds to exit.
b. To set the timing and sleep function under the power failure compensation mode please plugs theunit after power failure and the main unit memory would be OFF state.
.System Major Function Sensor Code Definition: Tai= Indoor Ambient Temperature, Tao=Outdoor Ambient Temperature,Tc1=Indoor Coil, Td= Air Discharge, Te= Outdoor Coil, Ts=Air Intake
1.1 Outdoor Unit Operation Frequency and Control
1.1.1 Compressor Operation Frequency Control
Compressor Operation Frequency Range:
1.1.2 Compressor StartupRegardless of target frequency of indoor unit, each time when compressor is from off to on, it mustmaintain 60Hz,90Hz for one minute (Frequency will be immediately decreased under the condition thatoutdoor unit air discharge temperature overheating protection is activated or over current ofcompressor) then the compressor will operate towards target frequency. This process does not exist innormal operation of unit.
Outdoor Unit
OutdoorTemperatureHeatingDefrostingOutdoorTemperatureCooling
Haier air conditioner Edition: 1.0-070801
- 22 -
1.1.3 Heating: When completing compressor startup operation, it will operate as per frequency of indoor unit. After 2 minutes, compressor operation frequency will be compensated as per relevant conditions.
1.1.4 Cooling & Dehumidification: When completing compressor startup operation, it will operate as per frequency of indoor unit. After 2 minutes, compressor operation frequency will be compensated as per relevant conditions.
1.1.5 Compressor Frequency Increase/Decrease Speed Rapid Frequency Increase/Decrease Speed 1 ----------1HZ/s Slow Frequency Increase/Decrease Speed 2 -----------1HZ/10s
1.2 Outdoor Fan Control
Outdoor TemperatureCoolingHeating
Compressor Operation Frequency
1.3 Outdoor Electronic Expansion Valve Control
1.3.1 The following is a description of electronic expansion valve operation: Energization Initial Operation
Haier air conditioner Edition: 1.0-070801
- 23-
Valve Complete Off Operation Valve operation after Compressor Startup and shutdown. Compressor Startup: Opening of valve must ensure restart of compressor when reaching benchmark opening. Compressor Shutdown It ensures complete off of valve after compressor shuts down.
1.3.2 Around the 2nd minute after compressor startup, valve opening can be adjusted based on various outdoor ambient temperature and corresponding frequency. Overheat benchmark will be adjusted if air discharge temperature is too high or too low in cooling or heating mode.
1.3.3 Valve Adjustment Time Interval and Method Valve Adjustment in Cooling Mode In cooling mode, if Tao>Tai The system will adjust valve based on difference between compressor intake air temperature and indoor unit coil temperature. Valve Adjustment in Heating Mode The system will adjust valve based on difference between compressor intake air temperature and defrosting temperature. 1.4 Four-way Valve Control
Defrosting Four-way Valve Control (please see defrosting process for details) Time sequence of the defrosting operation is as follows:
Four-way Valve Work Status in Other Modes: In heating mode, four-way valve is on. If compressor is off or is switched to non-heating mode, four-way valve ensures that it is off at least 2 minutes after compressor shuts down.
1.5 Outdoor Defrosting Control
1.5.1 Defrosting Mode Entry Conditions The unit will enter defrosting mode when compressor starts up and operates for 10 minutes continuously in heating mode or after compressor runs for an accumulated time of 45 minutes (Upon completion of defrosting or when switched to cooling mode, compressor accumulated operation time will be cleared) and when 2 minutes’ continuous checking by defrosting sensor TE (check frosting condition of outdoor unit heat exchanger) and outdoor ambient temperature sensor TA meets the following conditions: TE C×TAAmong which: C:TA 0 C=0.8 TA 0 C=0.6For area prone to frost, the value is set at 6 when unit leaves the factory. Defrosting entry temperature control -15 C×TA -5
1.5.2 Defrosting Time Interval time interval between two defrosting cycles is 45 minutes.
Haier air conditioner Edition: 1.0-070801
- 24 -
1.5.3 Defrosting Operation When defrosting begins, compressor will stop for one minute, external fan is running and 50s later, four-way valve will be off. When compressor starts, external fan will be off, compressor will run at 60HZ for 60s then move on to target frequency of 80HZ. During defrosting, compressor current and air discharge overheat protection features are effective. During defrosting, if compressor shuts down due to activation of protection feature or due to malfunction, it will resume after 3 minutes. In the unit is still within defrosting cycle, it will resume defrosting and startup of compressor will be based on the rule for defrosting startup. (The unit will exit defrosting mode and handle fault in the event of 3 consecutive restart failures.) On entering defrosting, it must guarantee that compressor will operate for a minimum of 2 minutes in defrosting mode before exit.
1.5.4 Defrosting Exit Condition When one of the following conditions is met, defrosting operation will be switched to heating operation.
1 :Temperature of outdoor heat exchanger exceeds 7 for 80s continuously2 : Temperature of outdoor heat exchanger exceeds 12 for 5s continuously3 :Defrosting operation continues for 9 minutes.
1.5.5 When defrosting exit conditions are met, the unit will operate as follows Compressor stops and external fan starts, 50s later, four-way valve will be on, 60s later, compressor will operate as per startup process.
1.6 PTC Output Control
When outdoor unit is energized, PTC output value is 0, 10s later, output value is 1. When compressor stops for 10 minutes continuously, PTC output value is 0. On receiving compressor startup instruction, initial PTC output is 1, and compressor startup will be performed 5s later.
. System Protection Function
2.1 Time interval between compressor shutdown and restart is set at 3 minutes to ensure that compressor will only restart after 3-minute shutdown and initial energization valves are turned on to adequate opening position after being fully turned off.
2.2 TD High Temperature Protections
As long as unit is on, the TD air discharge overheat protection feature will be activated, yet air discharge sensor fault must be alarmed 4 minutes after compressor starts.
Haier air conditioner Edition: 1.0-070801
5
TD Abnormal Shutdown
1 1 7 Rapid frequency drop 1HZ/s
1 1 2 Slow frequency drop (1HZ/10s)
1 0 8 Invariable frequency
1 0 5 Frequency rise (1HZ/10s)
98 Frequency rise 1HZ/1 s
When TD>110 for 20s continuously air discharge overheat protection will be activated and fault willbe reported to indoor unit.It will not continue in other conditions.
2.3 Outdoor Temperature Limit
Cooling: When outdoor temperature is lower than 15 , cooling operation will start, compressorfrequency is limited to less than 50 HZ, outdoor wind speed is forced at level 1.Heating: When outdoor temperature is higher than 20 , heating operation will start, compressorfrequency is limited to less than 50 HZ, outdoor wind speed is forced at level 1.
2.4 Rated Operation
Rated Cooling:When receiving the instruction of indoor unit rated operation, the unit will start rated cooling operation.Rated Heating:When receiving the instruction of indoor unit rated operation, the unit will start rated heating operation.
2.5 Special Features
1. Forced Cooling: When receiving indoor forced cooling signal, cooling operation will start in afrequency signaled by indoor unit. Only air discharge temperature and over current protection featuresare effective and other protection features are invalid.2. Rated, Middle and Minimum Capacity Operation: When receiving indoor, rated, middle andminimum capacity operation signal, outdoor unit will operate as per wind speed and frequency set byEEPROM and all the protection features are effective.
2.6 Fault Display and Treatment
In case outdoor unit faults, the alarm indicator lamp will blink and blink frequency is 1HZ Time intervalbetween blink cycles is 3s.Alarm indicator lamp is off when there is no fault.
Haier air conditioner Edition: 1.0-070801
- 2 6 -
4. Thermistor resistance chartIndoor ambiend temperature sensor
Temp. ( ) R (KO) Power Input (V)-20 281.34 0.33-19 263.56 0.35-18 247.84 0.37-17 231.66 0.40-16 217.35 0.42-15 204.02 0.45-14 191.61 0.47-13 180.04 0.50-12 169.24 0.53-11 159.17 0.56-10 149.77 0.59-9 140.99 0.62-8 132.78 0.65-7 126.11 0.69-6 117.93 0.73-5 111.22 0.76-4 104.93 0.80-3 98.04 0.84-2 93.52 0.88-1 88.35 0.920 83.50 0.971 78.94 1.012 74.67 1.063 70.65 1.104 66.88 1.155 63.33 1.206 60.00 1.257 56.88 1.008 53.91 1.359 51.15 1.41
10 48.51 1.4611 46.04 1.5112 43.72 1.5713 41.52 1.6314 39.45 1.6815 37.50 1.7416 35.66 1.80
Haier air conditioner Edition: 1.0-070801
- 2 7 -
17 33.92 1.8518 32.27 1.9119 30.72 1.9720 29.25 2.0021 27.85 2.0922 26.54 2.1523 25.30 2.2124 24.12 2.2725 23.00 2.3326 21.94 2.3827 20.94 2.4428 19.99 2.5029 19.09 2.5630 18.23 2.6231 17.42 2.6732 16.65 2.7333 15.92 2.7834 15.22 2.8435 14.56 2.8936 13.93 2.9537 13.04 3.0038 12.77 3.0539 12.23 3.1040 11.71 3.1541 11.22 3.2042 10.76 3.2543 10.31 3.3044 9.89 3.3545 9.46 3.3946 9.10 3.4447 8.74 3.4848 8.39 3.5249 8.05 3.5750 7.73 3.5151 7.43 3.6552 7.14 3.6853 6.86 3.7254 6.60 3.7655 6.34 3.8056 6.10 3.8357 5.87 3.3758 5.65 3.9059 5.44 3.9360 5.24 3.96
Haier air conditioner Edition: 1.0-070801
- 2 8 -
61 5.04 3.9962 4.86 4.0263 4.68 4.0564 4.51 4.0865 4.35 4.1166 4.13 4.1367 4.04 4.1668 3.90 4.1869 3.76 4.2170 3.63 4.2371 3.50 4.2572 3.38 4.2873 3.26 4.3074 3.15 4.3275 3.04 4.3476 2.94 4.3677 2.84 4.3878 2.74 4.4079 2.65 4.4280 2.56 4.43
Indoor pipe temperature sensorTemperature( ) R(KO) Power Input(V)
-20 90.79 0.90-19 85.72 0.95-18 80.96 0.99-17 76.51 1.04-16 72.33 1.08-15 68.41 1.13-14 64.73 1.18-13 61.27 1.23-12 58.02 1.28-11 54.97 1.33-10 52.10 1.39-9 49.40 1.44-8 46.88 1.50-7 44.46 1.55-6 42.21 1.61-5 40.08 1.66-4 38.08 1.72-3 36.19 1.78-2 34.41 1.84
Haier air conditioner Edition: 1.0-070801
- 2 9 -
-1 32.73 1.900 31.24 1.981 29.84 2.012 28.22 2.073 26.88 2.134 25.61 2.195 24.41 2.256 23.27 2.317 22.20 2.378 21.18 2.439 20.21 2.49
10 19.30 2.5411 18.43 2.6012 17.61 2.5613 16.83 2.7214 16.09 2.7715 15.38 2.8316 14.71 2.8817 14.08 2.9318 13.48 2.9919 12.90 3.0420 12.38 3.0921 11.64 3.1422 11.34 3.1923 10.87 3.2424 10.43 3.2925 10.00 3.3326 9.59 3.3827 9.21 3.4228 8.84 3.4729 8.48 3.5130 8.15 3.5531 7.83 2.5932 7.52 3.6333 7.23 3.6734 6.95 3.7135 6.68 3.7536 6.43 3.7837 6.19 3.8238 5.95 3.8639 5.73 3.8940 5.52 3.9241 5.32 3.9542 5.12 3.98
Haier air conditioner Edition: 1.0-070801
- 3 0 -
43 4.93 4.0144 4.75 4.0445 4.58 4.0746 4.42 4.1047 4.26 4.1248 4.11 4.1549 3.97 4.1750 3.83 4.2051 3.70 4.2252 3.57 4.2453 3.45 4.2654 3.33 4.2855 3.22 4.3156 3.11 4.3357 3.00 4.3558 2.90 4.3759 2.81 4.3860 2.72 4.4061 2.63 4.4262 2.54 4.4463 2.45 4.4564 2.36 4.4765 2.30 4.4866 2.23 4.5067 2.15 4.5168 2.09 4.5369 2.03 4.5470 1.96 4.5571 1.90 4.5772 1.85 4.5873 1.79 4.5974 1.73 4.6075 1.68 4.6176 1.63 4.6277 1.58 4.6378 1.54 4.6479 1.49 4.6580 1.45 4.66
-30
-28
-26
-24
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2
0123456789
1011121314151617181920212223242526
Outdoor ambient temp.sensor and Pipe sensor
Haier air conditioner Edition: 1.0-070801
- 3 1 -
27282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384
Haier air conditioner Edition: 1.0-070801
- 3 2 -
temperature Max Nomal Min temperature Max Nomal Min( ) (KO) (KO) (KO) ( ) (KO) (KO) (KO)-30 14646.0505 12061.7438 9924.4999 -2.96 2.45 57 129.2457 122.1630 115.3645 -1.40 1.34-29 13654.1707 11267.8730 9290.2526 -2.95 2.44 58 123.8956 117.2504 110.8618 -1.37 1.32-28 12735.8378 10531.3695 8700.6388 -2.93 2.44 59 118.7926 112.5589 106.5564 -1.35 1.30-27 11885.1336 9847.7240 8152.2338 -2.92 2.43 60 113.9241 108.0776 102.4388 -1.32 1.28-26 11096.6531 9212.8101 7641.8972 -2.91 2.42 61 109.2784 103.7961 98.5000 -1.30 1.26-25 10365.4565 8622.8491 7166.7474 -2.90 2.42 62 104.8443 99.7046 94.7315 -1.28 1.23-24 9687.0270 8074.3787 6724.1389 -2.88 2.41 63 100.6112 95.7939 91.1253 -1.25 1.21-23 9057.2314 7564.2244 6311.6413 -2.87 2.41 64 96.5692 92.0553 87.6735 -1.23 1.19-22 8472.2852 7089.4741 5927.0206 -2.86 2.40 65 92.7088 88.4805 84.3690 -1.20 1.17-21 7928.7217 6647.4547 5568.2222 -2.84 2.39 66 89.0211 85.0614 81.2048 -1.18 1.15-20 7423.3626 6235.7109 5233.3554 -2.83 2.39 67 85.4976 81.7908 78.1744 -1.15 1.12-19 6953.2930 5851.9864 4920.6791 -2.82 2.38 68 82.1303 78.6615 75.2715 -1.13 1.10-18 6515.8375 5494.2064 4628.5894 -2.80 2.37 69 78.9116 75.6668 72.4902 -1.10 1.08-17 6108.5393 5160.4621 4355.6078 -2.79 2.37 70 75.8343 72.8004 69.8249 -1.08 1.06-16 5729.1413 4848.9963 4100.3708 -2.77 2.36 71 72.8916 70.0561 67.2703 -1.05 1.03-15 5375.5683 4558.1906 3861.6201 -2.76 2.35 72 70.0770 67.4283 64.8213 -1.03 1.01-14 5045.9114 4286.5535 3638.1938 -2.75 2.34 73 67.3844 64.9115 62.4731 -1.00 0.99-13 4738.4141 4032.7098 3429.0191 -2.73 2.34 74 64.8080 62.5006 60.2211 -0.98 0.96-12 4451.4586 3795.3910 3233.1039 -2.72 2.33 75 62.3423 60.1906 58.0609 -0.95 0.94-11 4183.5548 3573.4260 3049.5312 -2.70 2.32 76 59.9821 57.9770 55.9885 -0.92 0.92-10 3933.3289 3365.7336 2877.4527 -2.69 2.31 77 57.7223 55.8552 53.9998 -0.90 0.89-9 3699.5139 3171.3148 2716.0828 -2.67 2.30 78 55.5583 53.8210 52.0912 -0.87 0.87-8 3480.9407 2989.2460 2564.6945 -2.66 2.29 79 53.4856 51.8706 50.2591 -0.85 0.84-7 3276.5302 2818.6731 2422.6139 -2.64 2.28 80 51.5000 50.0000 48.5000 -0.85 0.84-6 3085.2854 2658.8058 2289.2164 -2.63 2.28 81 49.7063 48.2057 46.7083 -0.85 0.85-5 2906.2851 2508.9126 2163.9230 -2.61 2.27 82 47.9835 46.4842 44.9911 -0.89 0.89-4 2738.6777 2368.3158 2046.1961 -2.60 2.26 83 46.3286 44.8323 43.3452 -0.93 0.92-3 2581.6752 2236.3876 1935.5371 -2.58 2.25 84 44.7385 43.2468 41.7672 -0.96 0.95-2 2434.5487 2112.5459 1831.4826 -2.56 2.24 85 43.2105 41.7248 40.2540 -1.00 0.99-1 2296.6230 1996.2509 1733.6024 -2.55 2.23 86 41.7386 40.2604 38.7996 -1.03 1.020 2167.2730 1887.0018 1641.4966 -2.53 2.22 87 40.3241 38.8545 37.4048 -1.07 1.061 2045.9191 1784.3336 1554.7931 -2.52 2.21 88 38.9643 37.5045 36.0668 -1.11 1.092 1932.0242 1687.8144 1473.1460 -2.50 2.20 89 37.6569 36.2078 34.7831 -1.14 1.133 1825.0899 1597.0431 1396.2333 -2.48 2.19 90 36.3996 34.9622 33.5513 -1.18 1.164 1724.6540 1511.6468 1323.7551 -2.47 2.17 91 35.1903 33.7653 32.3689 -1.22 1.195 1630.2870 1431.2787 1255.4324 -2.45 2.16 92 34.0269 32.6151 31.2338 -1.26 1.236 1541.5904 1355.6163 1191.0048 -2.43 2.15 93 32.9075 31.5096 30.1438 -1.30 1.277 1458.1938 1284.3593 1130.2298 -2.41 2.14 94 31.8302 30.4467 29.0970 -1.33 1.308 1379.7528 1217.2282 1072.8813 -2.40 2.13 95 30.7933 29.4246 28.0915 -1.37 1.349 1305.9472 1153.9626 1018.7481 -2.38 2.12 96 29.7950 28.4417 27.1254 -1.41 1.3710 1236.4792 1094.3200 967.6334 -2.36 2.11 97 28.8337 27.4961 26.1970 -1.45 1.4111 1171.0715 1038.0743 919.3533 -2.35 2.09 98 27.9078 26.5864 25.3048 -1.49 1.4412 1109.4661 985.0146 873.7359 -2.33 2.08 99 27.0160 25.7110 24.4470 -1.53 1.4813 1051.4226 934.9440 830.6210 -2.31 2.07 100 26.1569 24.8685 23.6222 -1.57 1.5214 996.7169 887.6792 789.8583 -2.29 2.06 101 25.3290 24.0574 22.8291 -1.61 1.5515 945.1404 843.0486 751.3077 -2.27 2.04 102 24.5311 23.2765 22.0662 -1.65 1.5916 896.4981 800.8922 714.8380 -2.26 2.03 103 23.7620 22.5245 21.3323 -1.69 1.6317 850.6086 761.0603 680.3265 -2.24 2.02 104 23.0205 21.8002 20.6261 -1.73 1.6618 807.3024 723.4134 647.6580 -2.22 2.00 105 22.3055 21.1025 19.9465 -1.77 1.7019 766.4212 687.8205 616.7252 -2.20 1.99 106 21.6159 20.4303 19.2924 -1.81 1.7420 727.8172 654.1596 587.4271 -2.18 1.98 107 20.9508 19.7825 18.6626 -1.85 1.7721 691.3524 622.3161 559.6694 -2.16 1.96 108 20.3091 19.1582 18.0563 -1.89 1.8122 656.8979 592.1831 533.3634 -2.14 1.95 109 19.6899 18.5564 17.4723 -1.93 1.8523 624.3328 563.6604 508.4261 -2.12 1.93 110 19.0924 17.9761 16.9098 -1.98 1.8924 593.5446 536.6540 484.7796 -2.10 1.92 111 18.5157 17.4166 16.3680 -2.02 1.9325 564.4275 511.0760 462.3510 -2.09 1.90 112 17.9590 16.8769 15.8458 -2.06 1.9626 536.9865 486.9352 441.1516 -2.07 1.89 113 17.4214 16.3564 15.3427 -2.10 2.0027 511.0105 464.0500 421.0258 -2.05 1.87 114 16.9023 15.8542 14.8577 -2.15 2.0428 486.4151 442.3499 401.9146 -2.03 1.86 115 16.4010 15.3696 14.3902 -2.19 2.0829 463.1208 421.7683 383.7626 -2.01 1.84 116 15.9167 14.9020 13.9394 -2.23 2.1230 441.0535 402.2430 366.5175 -1.99 1.83 117 15.4489 14.4506 13.5047 -2.27 2.1631 420.1431 383.7151 350.1301 -1.97 1.81 118 14.9968 14.0149 13.0855 -2.32 2.1932 400.3242 366.1295 334.5542 -1.95 1.80 119 14.5599 13.5942 12.6811 -2.36 2.23
E( )
E( )
Haier air conditioner Edition: 1.0-070801
Discharging Piper Sensor
-33 -
temperature Max Nomal Min mperatu Max Nomal Min( ) (KO) (KO) (KO) ( ) (KO) (KO) (KO)
E( )
E( )
33 381.5350 349.4341 319.7460 -1.93 1.78 120 14.1376 13.1879 12.2909 -2.41 2.2734 363.7176 333.5801 305.6645 -1.90 1.76 121 13.7294 12.7955 11.9144 -2.45 2.3135 346.8176 318.5216 292.2709 -1.88 1.75 122 13.3347 12.4165 11.5510 -2.50 2.3536 330.7839 304.2151 279.5286 -1.86 1.73 123 12.9531 12.0503 11.2003 -2.54 2.3937 315.5682 290.6199 267.4031 -1.84 1.71 124 12.5840 11.6965 10.8617 -2.58 2.4338 301.1254 277.6976 255.8620 -1.82 1.70 125 12.2270 11.3545 10.5348 -2.63 2.4739 287.4128 265.4119 244.8745 -1.80 1.68 126 11.8817 11.0240 10.2191 -2.68 2.5140 274.3905 253.7288 234.4118 -1.78 1.66 127 11.5475 10.7046 9.9142 -2.72 2.5541 262.0206 242.6161 224.4465 -1.76 1.64 128 11.2242 10.3957 9.6197 -2.77 2.5942 250.2676 232.0436 214.9529 -1.74 1.63 129 10.9112 10.0970 9.3352 -2.81 2.6343 239.0983 221.9825 205.9065 -1.71 1.61 130 10.6084 9.8082 9.0602 -2.86 2.6744 228.4809 212.4060 197.2844 -1.69 1.59 131 10.3151 9.5288 8.7945 -2.91 2.7145 218.3860 203.2887 189.0648 -1.67 1.57 132 10.0312 9.2586 8.5378 -2.95 2.7546 208.7855 194.6066 181.2273 -1.65 1.55 133 9.7563 8.9971 8.2895 -3.00 2.8047 199.6531 186.3369 173.7524 -1.63 1.54 134 9.4901 8.7441 8.0495 -3.05 2.8448 190.9639 178.4584 166.6217 -1.60 1.52 135 9.2322 8.4993 7.8175 -3.09 2.8849 182.6945 170.9508 159.8181 -1.58 1.50 136 8.9824 8.2623 7.5931 -3.14 2.9250 174.8228 163.7951 153.3249 -1.56 1.48 137 8.7404 8.0329 7.3760 -3.19 2.9651 167.3280 156.9733 147.1268 -1.53 1.46 138 8.5059 7.8108 7.1660 -3.24 3.0052 160.1904 150.4683 141.2090 -1.51 1.44 139 8.2787 7.5958 6.9629 -3.29 3.0453 153.3914 144.2641 135.5577 -1.49 1.42 140 8.0584 7.3875 6.7664 -3.33 3.0954 146.9136 138.3454 130.1598 -1.47 1.4055 140.7403 132.6980 125.0027 -1.44 1.3856 134.8559 127.3081 120.0746 -1.42 1.36
Haier air conditioner Edition: 1.0-070801
- 3 4 -
HSU-09,12,18,22HC03/R2(DB) Edition: 1.0-070801
Domestic Air Conditioner
5.5.1 Error Codes and Description
Code indication
indoorOutdoor
(LED1 flashtimes)
DescriptionReference
Page
Indoorand Outdoor15
Communication fault between indoor and outdoor
units
Room temperature sensor failure
Heat-exchange sensor failure
Indoor EEPROM error
Indoor fan motor malfunction
Indoor Malfunction
High work-intense protection
1 Outdoor EEPROM error
The protection of IPM
Overcurrent protection of AC electricity for
the outdoor model
4Communication fault between the IPM and outdoor
PCB
6 Power voltage is too high or low
8 Overheat protection for exhaust temperature
10 Frost-removing temperature sensor failure
12 Ambient temperature sensor failure
13 Exhaust temperature sensor failure
Outdoor Malfunction
Note indoor :the display board ,representative extinguish , representative flash , representative light
36-37
38
38
38
39
40
38
41
43
42
42
44
45
45
45
18 deviate from the normal for the compressor
19 Loop of the station detect error
24 Overcurrent of the compressor
25Overcurrent protection for single-phase of the
compressor
46
47
47
47
HSU-09,12,18,22HC03/R2(DB) Edition: 1.0-070801
-36-Domestic Air Conditioner
5.2 Trouble Shooting
5.2.1 between indoor and outdoor units : LED1 flash 15 times Communication fault between the indoor and
outdoor units
NO
YES
YES
YES
NO
NO
NO
YES
Restart the a/c and it
becomes normally? The outdoor mainboard needs dewetting
If starting up normally, but
malfunction occurs again
after a while
The outdoor mainboard needs dedusting
Check whether the linking cable
between the indoor and outdoor
is well connected and whether its
core wires are well insulated.
1. Reconnect the linking cable;
2. Replace the linking cable with new one.
I Check the status of LED1 on the indoor mainboard.
1)If LED1 keeps on lighting, the indoor mainboard is
damaged
2)If LED1 blinks interruptedly, measure the voltage
between Jumpers 3 and 4 of IC7on the indoor
mainboard with a multimeter. If the voltage is of a
constant value of 0VDC or 5VDC, the indoor
mainboard is damaged;
The indoor PCB might be
broken
HSU-09,12,18,22HC03/R2(DB) Edition: 1.0-070801
Domestic Air Conditioner
YES
If LED1 of indoor blinks interruptedly,
measure the voltage between Jumpers 3
and 4 of IC7on the indoor mainboard with a
multimeter. If the voltage varies between 0
and 3VDC, the outdoor mainboard is
damaged.
The outdoor PCB might be
broken
If LED1 of indoor keeps OFF
1. Test the outdoor power supply (230VAC and +310VDC) with a multimeter. If 230VAC is available
but 310DC not, rectifying bridge is damaged, replace it with a new one. If both 230VAC and
310DC are available, go forward to step 2.
2. Measure the voltage across Jumpers 1 and 2of IC6(7805) on the outdoor mainboard with a
multimeter. If +12DC is not available, the outdoor pcb is damaged, replace it with a new one. If
+12VDC is available, go forward to step 3.
3. Within two minutes after the machine is supplied with power and turn on, measure the AC voltage
between positions 1 and 3 on the terminal of outdoor unit with a multimeter. If the value varies
between 0 and 80 VAC, the outdoor mainboard is damaged, replace it with a new one. If the value is
constant at about 30V, the indoor mainboard is damaged, replace it with a new one.
HSU-09,12,18,22HC03/R2(DB) Edition:1.0-070801
-38-Domestic Air Conditioner
7.2.2 Indoor Malfunction: Room temperature sensor failure : Heat-exchange sensor failure
: Indoor or outdoor EEPROM error:
Check whether LED1 on theoutdoor unit blinks 1 times
The outdoor mainboard is damaged. Replace it with a
new one.
If the malfunction still existsthe indoor mainboard is damaged, and needs
replacing with a new one.
Yes
NO
YES
whether terminal CN8 on
indoor PCB contact wellt?
Pull out the terminals on the indoor mainboard and
reinsert them
Pull the sensor out of the mainboard
1) Measure the value of resistance Between its two
jumpers
2) Measure the temperature at the room temperature
sensing head.
Check the value of the
sensor to see whether the
sensor is damaged or not?
NO
Sensor is broken,replace it with new sensor
The indoor PCB is broken, replace with new indoor PCB
Yes
YesNO
HSU-09,12,18,22HC03/R2(DB) Edition:1.0-070801
-39 -Domestic Air Conditioner
:Indoor fan motor malfunction
Notes: When the unit is on ,don’t pull out or insert the terminal of the motor (CN9), or else The motor would be damaged.
YES
NO
YES
whether terminal CN9
and CN8 on indoor PCB
well inserted or not?
Pull out and reinsert the terminals
Electrify the machine again and turn it on in the cooling
operation
Measure whether there is voltage 60vac-230vac
between the red wire and the black wire of Terminal CN9
on the indoor mainboard.
NO
the indoor mainboard is damaged and need replace
check whether motor can run when turn on the unit the indoor motor is damaged and need replace
NO
When fan motor is running Measure whether there is
voltage pulse between the middle wire and the black side
wire of Terminal CN8 on the indoor mainboard.
YES
the motor of the indoor unit is damaged and need
replace
NO
the indoor mainboard is damaged and need replace
YES
HSU-09,12,18,22HC03/R2(DB) Edition: 1.0-070801
-40 -Domestic Air Conditioner
: High work-intense protection
YES
NO
the malfunction is reported
after the machine has run
for some time?
Check room temperature and pipe temp sensor.
Electrify the machine again and turn it on with the remote
controller, check whether the wind temperature is below
72
YES
NO
the indoor unit blows poorly
due to blocked filters or poor
condition of the fan?
1) Clean the filters
2) Reinstall the fan.
Use some tools to measure whether the pressure of the The system is over charged with gas
YES
the system is too high?
HSU-09,12,18,22HC03/R2(DB) Edition: 1.0-070801
-41-Domestic Air Conditioner
5.2.3 Outdoor Unit Malfunction
LED1 flash 2 times: The protection of IPM
YES
YES
NO
whether it is too high.? IPM Module might be poorly radiated and need to be
recoated with heat conducting paste and reinstalled.
Electrify the machine again and turn it on with the remote
controller, then measure temperature on the module
radiator
With a multimeter, test whether there is diode
characteristic between the three terminals U/V/W and
whether the two terminals P/N of IPM module and the
diode characteristic is exist.
NOIPM Module is damaged and needs replacing.
Test with a multimeter whether the resistance values
among Phases U, V and W of compressor are equal and
between 1 and 3 , if it does exist, the compressor
should be damaged.
HSU-09,12,18,22HC03/R2(DB) Edition:1.0-070801
-42-Domestic Air Conditioner
LED1 flash 4 times: Communication fault between the IPM and outdoor PCB
Indoor : LED1 flash 6 times : Power voltage is too high or low
NO
YES
NO
Are they good? 1) Pull out and reinsert the terminals.
2) Replace connected wire
1) Check whether Terminal CN14 and CN8 on the outdoor
mainboard CN10 and CN11 on IPM module
2) Check whether the connected wire between IPM and outdoor
Electrify the machine again and turn it on, Check whether
the voltage between 1 and 2 of Terminal CN8 is about
DC5V, Check whether the voltage between2 and 3 of
Terminal CN8 is about DC15V,
YES
Replace the outdoor IPM module with a new one.
Replace the outdoor mainboard with a new one
YES
NO
the voltage between P and
N of Terminal CN1 is below
120vDC or up 400vDC?
The IPM module is damaged and needs replacing
NO
YES
the voltage between 1 and 2
on the terminal of outdoor is
about 187-260VAC?
Check power supply.
NO
YES
the voltage between 2 and 4
on the rectifying bridge of
outdoor is 187-260VAC?
The reactor of outdoor is damage and replace a new one
the rectifying bridge or IPM module is damage and need tobe replaced.
HSU-09,12,18,22HC03/R2(DB) Edition:1.0-070801
-43-Domestic Air Conditioner
Indoor : LED1 flash 3 times : AC electricity protection
Electrify the machine again and turn it
on with the remote controller,If
malfunctions are reported before or upon
the compressor being started up
The compressor is started normally, but
malfunctions are reported after it has run
for some time.Check the power supply. If
the voltage is too low or too high
If the power supply is in OK,meassuer
whether the pressure of the system is too
high or too low?
The IPM is broken
repair The power supply
the system may have been
over or under charged
with gas
YES
YES
YES
NO
NO
HSU-09,12,18,22HC03/R2(DB) Edition:1.0-070801
-44-Domestic Air Conditioner
Indoor: LED1 flash 8 times: Overheat protection for exhaust temperature
NO
NO
YES
NO
the temperature exceeds
110 shortly after the
machine starts up?
1) The cryogen may have been leaked during
installation, or there may be leakage in the piping
system.
2) There may be other causes to make the exhaust
temperature too high.
Electrify the machine again and turn it on with the remote
controller, then measure the temperature at the exhaust
temperature sensor of the compressor on the outdoor unit
Measure the temperature at the exhaust temperature
sensor of the compressor on the outdoor unit
YES
NO
Malfunctions occur after running for
some time? even though the
measured temperature is below 110
.
Exhaust temperature sensor is broken and needs be
replaced
Pull out the exhaust sensor and measure its resistance
at standard temperatures according to the
resistance-temperature table
YES
The sensor is damaged. Replace the sensor with a new
one.
the results deviate much? YES
The sensor is damaged. Replace the sensor with a new
one.
The outdoor mainboard is damaged and needs be
replaced
NO
HSU-09,12,18,22HC03/R2(DB) Edition: 1.0-070801
-45-Domestic Air Conditioner
Indoor: LED1 flash 10 times: Frost-removing temperature sensor failure CN10 Indoor: LED1 flash 13 times: Exhaust temperature sensor failure CN13 Indoor: LED1 flash 12 times: Ambient temperature sensor failure CN11
NO
YES
CN10,CN11,CN13 on the
outdoor mainboard contact
well?
Pull out the terminals on the outdoor mainboard and
reinsert them.
Pull the sensor out of the mainboard
1) Measure the value of resistance between its two
jumpers
2) Measure the temperature at the room temperature
sensing head.
YES
whether the sensor is
damaged or not?
YES
Sensor is broken. Replace with new sensor
The Outdoor PCB is broken. Replace with new indoor
PCB
46
The malfunction of the compressor’ rotor circuitOutdoor: LED1 flash 18 times
Malfunction unsolved
YES
YES
NO
1. The wiring of compressor is incorrect or the
connection is poor;
2. The compressor is damaged
The IPM might be broken
Within 3 minutes after the machine is supplied
with power and turned on with the remote
controller, the outdoor unit stops shortly after
startup, and the compressor will start up again
10 seconds after the machine stops. The above
process repeats again and again
At the stopped state, LED1 on the outdoor PCB
blinks(1Hz)for 18 times, and after pause of 2
seconds or so, it blinks for the same times
again.
the Malfunctions exist also, The
compressor is damaged replace a new on
47
Yes
Loop of the station detect errorOutdoor: LED1 flash 19 times
Malfunction unsolved
Overcurrent of the compressor Outdoor: LED1 flash 24 timesOvercurrent protection for single-phase of the compressor Outdoor: LED1 flash 25times
Yes
YES
YES
NO
1. The wiring of compressor is incorrect
or the connection is poor;
2. The compressor is damaged
IPM Module is damaged and needs
replacing.
Within 3 minutes after the machine is suppliedwith power and turned on with the remote controller, the compressor couldnot stard up
At frist, the compressor start up ,soon the
compressor stopped with the LED1 on the
outdoor PCB blinks 1Hz for 19 times
the Malfunctions exist also, . The
compressor is damaged replace
new one
Electrify the machine again and turn it on with the
remote controller,If malfunctions are reported before
or upon the compressor being started up,
IPM Module is damaged and needs
replacing.
The compressor is started normally, but
malfunctions are reported after it has run for some
time.Check the power supply. If the voltage is too
low or too high
Repair the power supply
No
Haier air conditioner Edition: 1.0-070801
- 48-
6. Performance curves diagram 6.1 High drop and long pipe capacity modification curves
9
50
cono
ling
capa
city
(w
51
cono
ling
capa
city
(w
52
3
cono
ling
capa
city
( w
4
cono
ling
capa
city
( w
55
cono
ling
capa
city
(w
56
cono
ling
capa
city
(w
Haier air conditioner Edition: 1.0-070801
- 57 -
6.3 Air outlet temp.-ambient temp. Curves
HSU-09HC03/R2(DB)
air outlet temp.-ambient temperature table Indoor temp. Outdoor temp. (Humidity 46%)
DB/WB 18 20 25 32 35 40 43 46
18/12 4.80 4.71 4.47 5.31 5.25 5.30 5.81 6.1818/14 5.26 5.16 4.90 5.83 5.77 5.81 6.37 6.7820/15 9.08 8.97 8.54 9.04 9.64 10.32 10.64 10.9622/16 9.32 9.20 9.05 9.31 9.91 10.60 10.99 11.2925/18 9.57 9.44 9.25 9.58 10.19 10.89 11.34 11.6127/19 11.25 11.10 10.89 11.28 12.10 12.82 13.35 13.6930/22 13.16 13.13 13.06 13.68 14.18 14.78 15.15 15.3332/23 15.07 15.17 15.24 16.07 16.36 16.74 16.95 16.9732/24 15.37 15.47 15.54 16.40 16.69 17.08 17.29 17.31
pow
er c
onsu
mpt
ion(
w
Haier air conditioner Edition: 1.0-070801
- 58 -
HSU-12HC03/R2(DB)
air outlet temp.-ambient temperature table Indoor temp. Outdoor temp. (Humidity 46%)
DB/WB 18 20 25 32 35 40 43 46
18/12 4.53 4.46 4.25 5.10 5.06 5.04 5.55 5.99
18/14 4.98 4.91 4.68 5.61 5.57 5.54 6.11 6.59
20/15 8.74 8.65 8.56 8.77 9.38 9.98 10.30 10.70
22/16 8.98 8.88 8.76 9.04 9.65 10.26 10.65 11.02
25/18 9.22 9.11 8.96 9.30 9.92 10.54 10.99 11.34
27/19 10.88 10.75 10.57 10.97 11.71 12.44 12.97 13.38
30/22 12.76 12.75 12.71 13.33 13.85 14.37 14.74 15.00
32/23 14.63 14.75 14.85 15.69 15.99 16.30 16.51 16.61
32/24 14.93 15.05 15.15 16.01 16.32 16.63 16.85 16.95
pow
er c
onsu
mpt
ion(
w
9
Haier air conditioner Edition: 1.0-070801
- 60 -
HSU-22HC03/R22(DB)po
wer
con
sum
ptio
n(w
Haier air conditioner Edition: 1.0-070801
- 61-
6.4.1 Cooling discharge pressure curves
HSU-09HC03/R2(DB)
COOLING DISCHARGE PRESSURE TABLE
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB 16 19 22
15 2053 2255 233625 2078 2210 232130 2451 2623 269435 2764 2890 297140 3075 3156 324745 3429 3600 3641
Outdoor Temp
DIS
CH
AR
GE
PRES
SUR
E
Haier air conditioner Edition: 1.0-070801
- 62 -
HSU-12HC03/R2(DB)
COOLING DISCHARGE PRESSURE TABLE
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB 16 19 22
15 2020 2220 2300
25 2040 2170 2230
30 2410 2580 2650
35 2715 2840 2920
40 3020 3100 3190
45 3370 3540 3580
Outdoor Temp
DIS
CH
AR
GE
PRES
SUR
E
63
COOLING DISCHARGE PRESSURE
4
COOLING DISCHARGE PRESSURE
Haier air conditioner Edition: 1.0-070801
- 65 -
6.4.2 Cooling suction pressure curves
HSU-09HC03/R2(DB)
COOLING SUCTION PRESSURE TABLE
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB 16 19 22
15 664 752 764 25 693 772 776 30 696 777 775 35 706 780 796 40 744 822 838 45 772 854 869
Outdoor Temp
DIS
CH
AR
GE
PRES
SUR
E
Haier air conditioner Edition: 1.0-070801
- 66-
HSU-12HC03/R2(DB)
COOLING SUCTION PRESSURE TABLE
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB 16 19 22
15 620 693 720
25 648 712 731
30 650 717 730
35 660 720 750
40 696 760 790
45 723 790 820
Outdoor Temp
DIS
CH
AR
GE
PRES
SUR
E
67
COOLING DISCHARGE PRESSURE
8
COOLING DISCHARGE PRESSURE
Haier air conditioner Edition: 1.0-070801
- 69 -
6.4.3 Heating discharge pressure curves
HSU-09HC03/R2(DB)
HEATING DISCHARGE PRESSURE TABLE
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB 15 20 25
-15 2106 2274 2439
-10 2172 2363 2585
-5 2427 2543 2752
0 2393 2563 2764
5 2552 2733 2858
10 2920 3065 3370
15 3419 3602 3670
20 3060 3433 3603
Outdoor Temp
DIS
CH
AR
GE
PRES
SUR
E
Haier air conditioner Edition: 1.0-070801
- 70 -
HSU-12HC03/R2(DB)
HEATING DISCHARGE PRESSURE TABLE
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB 15 20 25
15 1690 1910 2160
10 1855 2080 2335
5 2020 2250 2510
0 2045 2385 2630
5 2200 2520 2750
10 2590 2940 3030
15 3110 3360 3430
20 2840 3160 3370
Outdoor Temp
DIS
CH
AR
GE
PRES
SUR
E
71
DISCHARGE PRESSUREHEATING
72
HEATING DISCHARGE PRESSURE
Haier air conditioner Edition: 1.0-070801
- 73 -
6.4.4 Heating suction pressure curves
HSU-09HC03/R2(DB)
HEATING SUCTION PRESSURE TABLE
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB 15 20 25
-15 260 259 262
-10 325 330 340
-5 394 415 420
0 430 470 478
5 470 540 545
10 600 648 682
15 757 757 818
20 719 749 762
Outdoor Temp
DIS
CH
AR
GE
PRES
SUR
E
Haier air conditioner Edition: 1.0-070801
-74 -
HSU-12HC03/R2(DB)
HEATING SUCTION PRESSURE TABLE
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB 15 20 25
-15 210 210 220
-10 280 285 295
-5 350 360 370
0 385 430 435
5 420 500 500
10 565 605 640
15 710 710 780
20 680 720 753
Outdoor Temp
DIS
CH
AR
GE
PRES
SUR
E
75
HRATING SUCTION PRESSURE
6
HRATING SUCTION PRESSURE
Haier air conditioner Edition: 1.0-070801
- 77 -
6.5 Sensible cooling value – temp. curves
HSU-09HC03/R2(DB)
Sensible cooling value - Temperature table Indoor temp. Outdoor temp. (Humidity 46%)
DB/WB 16 20 25 32 35 40 43 46
18/12 1199 1207 1215 1049 1056 1089 976 889 18/14 1561 1570 1620 1431 1403 1305 1221 1157 20/15 1923 1932 1942 1871 1750 1629 1527 1425 22/16 1883 1895 1907 1856 1725 1571 1466 1417 25/18 1842 1857 1871 1840 1700 1560 1468 1396 27/19 2038 1971 2008 1886 1820 1696 1604 1511 30/22 2246 2135 2276 2056 1958 1860 1731 1696 32/23 2321 2123 2280 2034 1991 1909 1813 1717 32/24 2380 2178 2339 2088 2044 1960 1862 1764
Haier air conditioner Edition: 1.0-070801
- 78-
HSU-12HC03/R2(DB)
Sensible cooling value - Temperature table Indoor temp. Outdoor temp. (Humidity 46%)
DB/WB 16 20 25 32 35 40 43 46
18/12 1926 1935 1943 1765 1773 1808 1687 1593
18/14 2315 2290 2378 2175 2145 2040 1950 1881
20/15 2703 2714 2724 2648 2517 2387 2278 2168
22/16 2660 2673 2686 2631 2491 2325 2213 2160
25/18 2617 2632 2648 2615 2464 2314 2215 2138
27/19 2731 2661 2700 2573 2490 2377 2281 2185
30/22 3050 2931 3083 2846 2741 2636 2498 2460
32/23 3130 2918 3087 2822 2776 2689 2585 2482
32/24 3194 2978 3150 2880 2833 2744 2638 2533
9
80
Haier air conditioner Edition: 1.0-070801
- 81-
6.6 Power consumption-temp. Curves
HSU-09HC03/R2(DB)
Power consumption value - Temperature table Indoor temp. Outdoor temp. (Humidity 46%)
DB/WB 16 20 25 32 35 40 43 46
18/12 268 276 291 388 515 735 791 846
18/14 342 350 367 474 614 856 917 978
20/15 443 422 410 611 642 777 854 932
22/16 446 424 411 627 650 778 857 937
25/18 448 426 412 642 658 779 860 941
27/19 466 443 430 665 680 804 887 970
30/22 485 462 448 687 703 829 914 999
32/23 491 454 427 646 682 827 924 1021
32/24 510 464 436 657 694 840 938 1036
power consumption
pow
er c
onsu
mpt
ion(
w
Haier air conditioner Edition: 1.0-070801
- 82 -
HSU-12HC03/R2(DB)
Power consumption value - Temperature table Indoor temp. Outdoor temp. (Humidity 46%)
DB/WB 16 20 25 32 35 40 43 46
18/12 800 808 824 929 1066 1304 1364 1424
18/14 880 889 906 1022 1173 1434 1500 1566
20/15 989 966 953 1170 1203 1349 1433 1517
22/16 992 968 954 1187 1212 1350 1436 1522
25/18 994 970 955 1204 1220 1351 1439 1527
27/19 1014 989 974 1228 1245 1378 1468 1558
30/22 1034 1009 994 1253 1270 1406 1497 1589
32/23 1040 1001 971 1208 1247 1403 1508 1613
32/24 1245 1011 981 1220 1259 1417 1523 1629
power consumption
pow
er c
onsu
mpt
ion(
w
83
power consumption
power consumption
pow
erco
nsum
ptio
n(w
84
power consumption
power consumption
pow
erco
nsum
ptio
n(w
85
Haier air conditioner Edition: 1.0-070801
- 86 -
HSU-18HC03/R2(DB)
NOISE LEVEL 100Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 6000Hz 8000Hz
INDOOR 46.4 43.5 42.3 40.1 39.3 32.8 28.0 0.0 0.0 OUTDOOR 57.1 54.1 52.4 50.7 47.3 41.4 34.9 28.5 26.4
dB(A
)
HSU-22HC03/R2(DB)
NOISE LEVEL 100Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 6000Hz 8000Hz
INDOOR 47.7 44.9 43.3 41.5 40.6 33.1 28.3 0.0 0.0
OUTDOOR 58.0 55.0 53.4 51.6 48.6 42.4 35.9 29.1 27.6
dB(A
)
Haier air conditioner Edition: 1.0-070801
- 87 -
6.8 Compressor performance curves
HSU-09HC03/R2(DB) COMPRESSOR:DA108X1C-20FZ3
SERIAL NUMBER 1 2 3 4 5 6 7
FREQUENCY 30 50 60 80 90 110 120
INPUT POWER 542 675 820 982 1100 1251 1319
INPUT POWER
HSU-12HC03/R2(DB) COMPRESSOR:DA89X1C-20FZ
INPUT POWER
8
Haier air conditioner Edition: 1.0-070801
- 89-
7. Wiring diagram
Haier air conditioner Edition: 1.0-070801
- 90 -
TO IN
DO
OR
UN
IT
MAIN CONTROL BOARD
T25A/250VAC
Remark the dotted parts are optional for different unit.
FUSE1
FUS
E2
HSU-09HC03/R2(DB)
Haier air conditioner Edition: 1.0-070801
- 91-
Haier air conditioner Edition: 1.0-070801
- 92 -
TO IN
DO
OR
UN
IT
MAIN CONTROL BOARD
T25A/250VAC
Remark the dotted parts are optional for different unit.
FUSE1
FUS
E2
HSU-12HC03/R2(DB)
Haier air conditioner Edition: 1.0-070801
- 93-
Haier air conditioner Edition: 1.0-070801
- 94 -
T25A
/250
VAC
HSU-18HC03/R2(DB)
Haier air conditioner Edition: 1.0-070801
- 95 -
Haier air conditioner Edition: 1.0-070801
- 96-
T25A/250VAC
HSU-22HC03/R2(DB)
7
12
34
5
ABCD
65
43
21
D C B A
Title
Num
ber
Revi
sion
Size B Date:
9-Au
g-20
07Fi
le:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 161718192021222324252627282930
31
32P0
4/IN
T24
P05/
INT2
5
P06/
INT2
6
P61
P07/
INT2
7
P60
/RST
X0 X1 VSS
P37/
BZ/P
PG
P36/
INT1
2
P35/
INT1
1
P34/
T0/IN
T10
P33/
EC
CP3
2/UI
/SI
P31/
UO/S
O
P30/
UCK/
SCK
P50/
PWMP70
P71
P72
P40/
AN0
P41/
AN1
P42/
AN2
P43/
AN3
P00/
-INT2
0/A
N4
P01/
-INT2
1/A
N5
P02/
-INT2
2/A
N6
P03/
-INT2
3/A
N7
VCC
FLZ
BUZ1
R2 1K
R1 220
+12V
R4 10K
R510
K
nega
tive
ion
exch
ang
fres
hai
r
outd
oor
comm
unic
atio
nou
tput
over
zero
chec
k
shri
nkti
m e
swit
ch
R12
10K
CN10
TEST
+5V
SW1+5
V+5
V
C410
4OS
C1
8M
123CN
8R7
10K
R6 2.2K
C6 102
+5V
PGfe
edba
ckre
mote
rece
ive
1 2 3 4 5 6 7 8910111213141516
12345CN6
+12V
ABCD
1 2 3SW2
R10
2.2K
+5V
R92.
2K
auto
run
type
choo
se
C10
104
C7 102
1 2 3 45678
+5V
C11
104
IC2
IC3
IC1
+5V
TIM
ERRU
N
GND
+5V
REC
1 2 3 4CN4
+5V
R13
3.3K
R14
20K
C12
102
C13
102
ROOM
PIPE
R15
10K
fan
outp
utpa
nel
choo
se
step
moto
rch
oose
outd
oor
comm
unic
atio
nin
put A
BC
buzz
er
TXO
TXI
FLZ
PGO
C110
2
C2 103
C5 103
C910
3R32
1K
E84.
7U R19
10K
R18
10K R2
01K Q3 90
13R1
7
10K
E4
470u
F/16
V
C15
104
Vout
3GND
2Vi
n1
IC4
7805
FUSE
1
T3.1
5A25
0VA
CC2
0
1uF/
275V
AC
1
2
3
4
IN40
07
ZE1
S14K
350
E3
1000
uF/3
5V
C14
104
+5V
+12V
D5 IN40
07
CN14
AC-L
AC-N
D1D2
D3D4
+5V
RL1
1 2 3 4 5
CN9 FL
Z
+12V
FLZ
FRED FW
HITE
C18
103/
275V
C19
1.2u
F/45
0VA
C
AC-L
CPGO
AC-N
123 4 1 2 3
456TLP4
21
TLP3
71
C17
104
R28
330K
R27
2.2K
LED1
D7 IN40
07D6 IN
4007
R29
2W6.
8K
R26
2.2K
R25
10K
C16
102+5
V
outd
oor
com
mun
icat
ion
inpu
t
+5V
R30
330
Q2 9013
outd
oor
com
mun
icat
ion
outp
ut
R24
120/
1W
PGDR
IVE
+12V
IC5
TLP3
526
R21
680
IC8
IC7
R31
1K
C21
104
C22
104
1 2 3SW3
R39
2.2K
1 2 3 4 5 6 7CN2-
1 sour
ceG
sour
ceR
R34
470
R36
470
R37
100
R38
10K
R35
1K
C23
102
12CN
5
COM22
0-N
1 2 3
CN1-
1
123
CN1-
2
CN11CN
12
E74.
7U+5
R11
2.2K
98
12
34
ABCD
43
21
D C B A
PTC4
1IR
Q2
RST
3PT
F0/T
ACH
24
PTF1
/TAC
H3
5PT
F2/T
BCH2
6PT
F3/T
BCH3
7PT
F4/T
BCH0
8NC
9PT
F710
PTF5
/TBC
H111
PTF6
12PT
E0/T
xD13
PTE1
/RxD
14PT
E215
PTE3
16
PTE417
PTE5/MISO
18
PTE6/MOSI19
PTE7/SPSCK 20
VSS21
VDD 22PTG0/KBD0 23PTG1/KBD1 24PTG2/KBD2 25
PTA0 26PTA1 27PTA2 28PTA3 29PTA4 30PTA5 31PTA6 32
PTA7
33PT
B0/A
TD0
34PT
B1/A
TD1
35PT
B2/A
TD2
36PT
B3/A
TD3
37PT
B4/A
TD4
38PT
B5/A
TD5
39PT
B6/A
TD6
40PT
B7/A
TD7
41PT
D0
42PT
D1
43VD
DAR
EF44
AVSS
/VRE
FL45
PTD
246
PTD
347
PTH
048
PTH149 PTD450 PTD551 PTD652 PTD753VREFH 54VDDA 55VSSA 56CGMXFC 57OSC2 58OSC1
59PTC0 60PTC1 61PTC2 62PTC3 63PTC5 64
IC9
MC9
08AB
32CF
UE
R58 1
0K-0
805±
5
+5
C29
0.1uF
-080
5
1 2
CN7
B2B-
XH-A
R59 1K
-080
5±5
Door
Switc
h
R70
10K-
0805
±5
C15
0.1uF
-080
5
R93
100
-080
5±5
C17
0.1uF
-080
5
+5P1
2SA1
037A
K
R77
2K-0
805±
5
R71
2K-0
805±
5
R78
10K-
0805
±5
R76
10K-
0805
±5
IRQ
RST
R74
10K-
0805
±5
IRQ
IR SDA
SCL
BUZZ
Uhom
eTXD
Uhom
eRXD
FAN
Retu
rnFA
Nou
t
HealthStep_DStep_CStep_BStep_A
XT/T
est
Room
Pipe
Rem
ote_i
n
Remote_outDoor
To dispTo disp
To disp
YJ_keyTo disp New_fan
COM_INCOM_OUT
R6510K-0805±5
R6610K-0805±5
R64
560
-080
5±5
A0 A1 A2 VSS
SDA
SCL
TESTVC
C1 2 3 4
5678IC
5
AT24
C02B
C14
0.1uF
-080
5
+5V
R87
220
-080
5±5
BUZZ
1
BEEP
-PKM
13EP
Y-40
02+12V
R86
2K-0
805±
5
N1
2SC2
412
R50
4.7K
-080
5±5
R52 10K-0805±5
+5V
U_ho
me
+5V
GND
TXD
RXD
C27
0.01u
F-08
05
1234
CN12
5267
-04A
R791K-0805±5
R8510K-0805±5
R84
100
-080
5±5
R83
100
-080
5±5
R9
1K-0
805±
5
1 2N4
2SC2
412R8 4.7K
-080
5±5
R97
300
-080
5±5
+5V
R91
10K-
0805
±5
+5V
C30.0
1uF-
63V
R733
0K-1
/4W
±5
R14
2K-1
/4W
±5
R18
10K-
1/2W
±5Co
mmu
C32
0.01u
F-08
05
C2
0.01u
F-63
V
D5
1N40
07D6 1N
4007
IC4
TLP4
21
IC3
TLP3
71
LED1
3
1 2 3 4 5 6 7 8910111213141516
IC6
ULN
2003
A
R5110K-0805±5
R261
K-08
05±
5R1
91K-
0805
±5
R201
0K-0
805±
5R2
11K-
0805
±5
R221
K-08
05±
5R2
310K
-080
5±5
12345CN5
Step
+12V
12
CN4
B2B-
VH-A
+12V
New
Win
d
+5
C35
0.01u
F-08
05C3
60.0
1uF-
0805
1 2 3 4
CN8
B4B-
XH-A
E10
4.7uF
/50V
E9 4.7uF
/50V
R41
1K-0
805±
5
R32
20K-
0805
±1
R31
3.3K
-080
5±1
R42
1K-0
805±
5
roompipe
R27
10K-
0805
±5+5
C34
0.1uF
-080
5
1 2
CN11
TCJ-0
2
R30
1K-0
805±
5R33
2K-0
805±
5
+12
C30
0.01u
F-08
05+5V
N3 2SC2
412
N2
2SC2
412
R55
10K-
0805
±5
R34
10K-
0805
±5
R56 1K
-080
5±5
remo
te
R35
4.7K
-080
5±5
R36
27-0
805±
5
R57
4.7K
-080
5±5
1 2
CN6
B2B-
XH-A
(Red
)
1234567CN9
R60
300
-080
5±5
R61
300
-080
5±5
R62
300
-080
5±5
R73
220
-080
5±5
+5V
E11
100U
F/25
V
C18
0.00
1uF-
0805
Todis
play
C22
0.1uF
-080
5
+5V
GND
IRC2
5
0.001
uF-0
805
C24
0.001
uF-0
805
C23
0.001
uF-0
805
C21
0.001
uF-0
805
C26
0.001
uF-0
805
C20
0.01u
F-08
05
R8110K-0805±5
R8010K-0805±5
R7510K-0805±5
C19
0.1u
F-08
05SW
1JT
P285
+5V
R92
1K-0
805±
5
R63
10K-
0805
±5 Switc
h
R44
10M
-080
5±5
1 3
2XT
1
FCR8
.0MC5
C12 0.
01uF
-080
5C1
60.
001u
F-08
05 C13
0.1u
F-08
05
+5V
C31
0.00
1uF-
0805
C37
0.1u
F-08
05
R4310K-0805±5
R4810K-0805±5
+5V
R40
10K-
0805
±5
R39
10K-
0805
±5
R38
10K-
0805
±5
R37
10K-
0805
±5
R13
10K-
0805
±5
R12
10K-
0805
±5
R46
10K-
0805
±5
R45
10K-
0805
±5
R29
10K-
0805
±5
R28
10K-
0805
±5
R47
10K-
0805
±5
R4910K-0805±5
R24
10K-0805±5+5
V
E13
220u
F/25
V
C28
0.1uF
-080
5
+5V
+5V
R941K-0805±5
R95
10K-
0805
±5
R53 10K-0805±5
R54 10K-0805±5
R82 10K-0805±5
R15
10K-
1/2W
±5
+5V
B
AA/
B
R25
3.3K
-080
5±1
SW3
JSS1
270
+5V
35 25typ
e
R10
3.3K
-080
5±1
SW2
JSS1
270
R72
100
-080
5±5
1 2 3 4 5
CN10
Prog
ramDA
T+5
V
GND
OSC1
+5V
E12
100u
F/25
V
+5V
1CN
3
250
DAT
DAT
B5B-
XH-A
(red)
B7B-
XH-A
99
12
3
ABCD
43
21
D C B A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21222324252627282930313233343536373839404142
VCC
VREF
AVSS
P44/
INT3
/PW
MP4
3/IN
T2/S
CMP2
P30/
AN0
P31/
AN1
P32/
AN2
P33/
AN3
P34/
AN4
P42/
INT1
P41/
INT0
P40/
CNTR
1P2
7/CN
TR0/
SRD
Y1
P00/
SIN2
P01/
SOUT
2
P03/
SRDY
2P0
2/SC
LK2
P26/
SCLK
P25/
TXD
P24/
RXD
P23
P22
CNVS
SP2
1/XC
INP2
0/XC
OUT
RESE
TXI
NXO
UTVS
S
P04
P05
P06
P07
P10/
(LED
0)P1
1/(L
ED1)
P12/
(LED
2)P1
3/(L
ED3)
P14/
(LED
4)P1
5/(L
ED5)
P16/
(LED
6)P1
7/(L
ED7)
5V
AC-L
AC-N
FUSE
1
T25A
/250
V
RL3
JZC-
43F
RL2
JZC-
43F
RL1
JZC-
33F
COM
LH
123CN
20
four
way
valv
e C47
103/
275V
AC
comm
unic
ate
C7 103/
275V
AC
R4 220K
R3 220K
R2 220K
R515
K
R615
K
R715
K
D1 IN40
07C6 22
U/25
0V/4
50V
D3 IN40
07
R8 1K
R9 330K
R122
K/2W
D2 IN40
07
A1
K2
C4
E3
IC12
PC81
7AA1
K2
C5
E4
B 6
IC13
TLP3
71
D4IN
4007
C48
102/
50V
C34
103/
50V
R43
10K
5V
R44
1K
Q3 9013
R45
330
R41
5.1K
R54
5.1K
Q1 9012
123CN14
Mod
ulec
omm
unica
te(B)
C33
102/
50V
5V COM
GND
Vin
1
GND2
Vout
3IC
8T6
00D
R53
10K
C32
104/
50V
5V
Y1 4M
12V
2 13 4567 891312111014
C38
104/
50V
1615
123456CN
16
electronic expansion valve
12V
12V A B C D
R36
1K
R34
1K
R37
1K
C42
104/
50V
C41
104/
50V
C40
104/
50V
R32
20K/
1%R3
120
K/1%
R30
47K/
1%
LED1
ERR
ORR5
810
K
5V
12345 6 7 8
IC11
24C0
2
5V
123
CN11
Air temperature(Y)
123CN
13
discharge(W)
12CN
10
defrost(W)
5V
Vin
1
GND2
Vout
3IC
6L7
805C
V
C45
104/
50V
C24
100U
/16V
/50V
12V
R51
10K
IC10
CN3
IC9
3858
8
R204
47
IC20
1PC
817
R201
47
C209
104/50V
IC10
2TL
431A
C201
102/
100V
1 2 3CN8
L202
20UH
/1A
ZD1
IN59
48B
C204
470U
/25V
/35V
C205
100U
/16V
/50V
C202
470U
/25V
/35V
C31
104/
50V
R50
10K
R52
10K
12CN
19
TEST 12
CN17
HEA
T
12CN
18
COOL
5V
R56
2.2K
C37
104/
50V
R35
1K
R33
20K/
1%
C39
104/
50V
123CN
12
suck(R)
SW3
FASW
4FA
NSW
1UP
SW2
DOW
N
C43
102/
50V
C44
102/
50V
R61
10K/
1%
R62
10K/
1%
R48
5.1K
/1%
R49
20K/
1%
R46
20K/
1%
R47
5.1K
/1%
5V
C10447U/25V
CY1
222/
2KV
C25
2U/4
50V
1234
CN7
D201 ER
302
D103 M
UR13
0
D202 M
BR11
00
D102
ER10
6
C206
102/
100V
R203
47C2
0810
4
R202
1K/0
.5W
C210
104/
50V
5V12
V100
0MA
C207
470U
/25V
/35V
R206330/1W
15V3
00M
AC2
84.
7U/1
6V
C27
4.7U
/16V
C29
4.7U
/16V
C30
4.7U
/16V
R209
5.1K
/1%
R208
1KR2
07
5.1K
/1%
R205
1KC2
0310
4/50
V
ULN2003
R28
5.1K
R40
10K
1 2CN15
PCco
mmun
icate(
BL)
COM
GND
R29
1K
Q4 9013
R57
5.1K
D5IN4007
NP
R105
10K R1
101K
R111
2/1W
R112 100K/2W
R106
15
C102
103/
50V
1 2 3 45678
IC10
1
NCP1
200P
100
910
5V40
0MA
Q101
IRFU
C20
76
4 5
C105
472/
2KV
CX10
110
4/27
5V
VCC
R107
20K/
1%
1 3
R103
5.1K
R63
100/
1W
RL4
JQX-
102F
PE
C1
225/
275V
ZE1
S14K
350
SA1
RA-3
62M
L38m
H/1
5A
C222
5/27
5V
C4 472/
250V
/275
V
C547
2/25
0V/2
75V
ZE2
S14K
350
CN4
PTC1
AC-L
OUT
AC-N
OUT
relayCN
5
T101
E220
34
R55
10K(
nosu
ckpi
pene
edto
add
)
12CN
22
PC
R60
10K
R59
10K
5V
R11
1K
R10
1K
R12
1KR1
31K
R65
10K
R38
1KR27
10K
C49
103/
50V
ZE3
S14K350
ZE4
S14K350
ZE5
S14K
350
R14
1M
C847
2/25
0V/2
75V
C947
2/25
0V/2
75V
1 2 3 4 5
CN9
AC FAN
C C
CN23
CN24
C35
104/
50V
D6 4148
C26
4.7U
/16V
C46
104/
50V
A1
K2
C4
E3
IC5
PC81
7A
A1
K2
C4
E3
IC4
PC81
7A
123456CN
21
DCfan
C22
103/
50V
C36
102/
50V
PN15V
feedf
ack
move
spee
dR2
51K
R22
1K R23
2.2K
R21 3
30
ZD3
5.1V
/0.5
W
ZD2
10V/
0.5W
R26
1K
R24
330/
1W
R39
330
R425.1K
C2347U/25V
5V
Q290
13
CN1
CN2
Q5 9013
D7IN4007
RL5
JZC-
43F
CN25
FUSE
2T1
A/25
0V
R64
5.1K
W B
123CN
26
FAN
COM
C
W18
R210220
R211
220
LED2
R66220K/2W
100
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21222324252627282930313233343536373839404142
VCC
VREF
AVSS
P44/
INT3
/PW
MP4
3/IN
T2/S
CMP2
P30/
AN0
P31/
AN1
P32/
AN2
P33/
AN3
P34/
AN4
P42/
INT1
P41/
INT0
P40/
CNTR
1P2
7/CN
TR0/
SRD
Y1
P00/
SIN2
P01/
SOUT
2
P03/
SRDY
2P0
2/SC
LK2
P26/
SCLK
P25/
TXD
P24/
RXD
P23
P22
CNVS
SP2
1/XC
INP2
0/XC
OUT
RESE
TXI
NXO
UTVS
S
P04
P05
P06
P07
P10/
(LED
0)P1
1/(L
ED1)
P12/
(LED
2)P1
3/(L
ED3)
P14/
(LED
4)P1
5/(L
ED5)
P16/
(LED
6)P1
7/(L
ED7)
5V
AC-L
AC-N
FUSE
1
T3.1
5A/2
50V
RL3
JZC-
32F
RL2
JZC-
32F
RL1
JZC-
33F
COM
LH
123CN
20
4-Va
lve
C47
103/
275V
AC
Indo
or-C
om
C7 103/
275V
AC
R4 220K
R3 220K
R2 220K
R515
K
R615
K
R715
K
D1 IN40
07C6 22
U/25
0V
D3 IN40
07
R81KR9 33
0
R1
22K/
2WD2 IN
4007
A1
K2
C4
E3
IC11
TLP5
21
A1
K2
C5
E4
B 6
IC12
TLP3
71
D4IN
4007
C48
102
C34
102
R43
10K
5V
R44
1K
Q3 9013
R45
330
R41
5.1K
R54
5.1K
Q1 9012
123CN14
Mod
uleC
om
C33
102
5V COM
GND
Vin
1
GND 2
Vout
3IC
8T6
00D
C32
104
5V
Y1 4M
12V
321 4567 891312111016
C43
104
15 14
123456CN
16
ELEC-EXPANSIONVALVE
12V
12V A B C D
5V
R36
1K
R34
1K
R37
1K
C42
104
C41
104
C40
104
R32
20K
R31
20K
R30
47K
LED1
ERR
OR
R58
10K
5V1234
5 6 7 8
IC11
24C0
2
5V
123
CN11
Tao(yellow)
123CN
13
Td(white)
12CN
10
Te(white)
5V
Vin
1
GND2
Vout
3IC
6L7
805C
V
C34
104
C22
100U
/16V
12V
IC10
CN1
CN3
CN2
IC6
3858
8
R204
47
IC20
1PC
817
R201
47
C209
104
IC10
2TL
431A
C201
471/
100V
1 2 3CN8
Mod
uleP
ower
L202
20UH
/1A
ZD1
IN59
48B
C204
470U
/25V
C205
100U
/16V
C202
470U
/25V
C31
104
12CN
19
TEST 12
CN17
HEA
T
12CN
18
COOL
5V
R56
2.2K
C37
104
R35
1K
R33
20K
C39
104
Td Ts Te Tao
123CN
12
Ts(Red)
SW3
FASW
4FA
NSW
1UP
SW2
DOW
N
C43
102
C44
102
R61
10K
R62 1
0K
R485
.1K
R49
20K
R46
20K
R47
5.1K
5V
C104
47U/
25V
CY1
222/
1KV
1 2 3 4 5 6 7 8 9
CN9
AC-M
otor
CC
C25
3U/4
50V
1234
CN7
D201 M
BR31
00
D103 M
UR11
5
D202 M
BR11
00
D102
IN49
37
C205
471/
100V
R203
47
C208
104
R202
1K/0
.5W
C210
104
5V12
V
C202
470U
/25V
R206
330/
1W
15V
C28
4.7U
/16V
C27
4.7U
/16V
C29
4.7U
/16V
C30
4.7U
/16V
R209
5.1K
R28
1K
R207
5.1K
R205
100
C203
104
1 2CN22
PTC
ULN2003
R38
1K
R27
10K C3
610
2
R28
5.1K
R40
10K
1 2CN15
PC-C
om(g
reen)
R29
1K
Q4 9013
R57
5.1K
D5 IN40
0712
VPT
CN
P
R105
10K R1
101K
R111
2/1W
R112 100K/1W
R106
15
C102
103
1 2 3 45678
IC10
1
NCP1
200P
100
910
5V
Q101
IRFU
C20
76
4 5
C105
472/
1KV
CX10
110
4/27
5V
VCC
R107
20K
1 3
R103
4.7K
R63
100/
1W
T101
E220
34
12CN
23
PC
R53
10K
R60
10K
R52
10K
R50
10K
R51
10K
R59
10K
GND
COM
R55
10K
NO.0010513988
9 Installation
A G
4.Hexagon wrench (5mm)
Plastic cap4X25Screw
Cushion
Drain-elbow
Accessory partsNumber ofarticles
Accessory partsNo.
Remote controller
R-03 dry battery
Mounting plate
Drain hose
Drawing for the installation of indoor and outdoor units
Read this manual before installation
1.Driver2.Hacksaw3.Hole core drill
5.Spanner(14,17,19 and 24 mm)6.Torque wrench(17mm,22mm,24mm)7.Pipe cutter8.Flaring tool
9.Knife10.Nipper 13.Reamer11.Gas leakage detector or soap-and-water solution
12.Measuring tape
Explain sufficiently the operating means to the useraccording to this manual.
Necessary Tools for Installation
Arrangement of piping directions
Rear leftRearrightLeft
BelowRight
mor
e th
an 5
cm
more than 60cm
more than 10cm
more than 15cm
more than 10cm
more than 10cm
more than 10cm
Attention must be paid tothe rising up of drain hose
The marks from to in the figure are the parts numbers.
The distance between the indoor unit and the floor should bemore than 2m.
14.Refrigerant oil
Optional parts for pipingMark Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screwsConnecting electric cablefor indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Haier air conditioner Edition: 1.0-070801
101
-102-
Liquid pipe
Gas pipe 9.52mm(3/8")
Fixing of outdoor unit
Indoor Unit Selection of Installation Place Outdoor Unit
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally.When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nailsor wires in consideration of earthquake and strong wind.If vibration may affect the house, fix the unit by attaching a vibration-proof mat.
Place, robust not causing vibration, where the body can be supportedsufficiently.Place, not affected by heat or steam generated in the vicinity, whereinlet and outlet of the unit are not disturbed.Place, possible to drain easily, where piping can be connected with theoutdoor unit.Place, where cold air can be spread in a room entirely.Place, nearby a power receptacle, with enough space around. (Referto drawings).Place where the distance of more than lm from televisions, radios,wireless apparatuses and fluorescent lamps can be left.In the case of fixing the remote controller on a wall, place where theindoor unit can receive signals when the fluorescent lamps in the roomare lightened.
Place, which is less affected by rain or direct sunlight and issufficiently ventilated.Place, possible to bear the unit, where vibration and noise arenot increased.Place, where discharged wind and noise do not cause anuisance to the neighbors.Place, where a distance marked is available as illustratedin the above figure.
Power Source
Selection of pipe
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.Install an exclusive branch circuit of the power.A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
To this unit, both liquid and gas pipes shall be insulatedas they become Iow temperature in operation.Use optional parts for piping set or pipes covered withequivalent insulation material.The thickness of the pipe must be 0.8mm at least.
For 18 22
6.35mm(1/4")
12.7mm(1/2")
HSU-22HC03/R2(DB)
113.5 583 113.5
319.
5
Floor fixing dimensionsof the outdoor unit(Unit:mm)
HSU-18HC03/R2(DB)
Floor fixing dimensionsof the outdoor unit(Unit:mm)
140 500 140
256
HSU-12HC03/R2(DB)HSU-09HC03/R2(DB)
For 09 12
6.35mm(1/4")
Haier air conditioner Edition: 1.0-070801
-103-
WeightThread
150mm 70mm
Holes for fixing the mounting plate
Fit the level line
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.3. Find the wall hole location Amm using a measuring tape
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
When the mounting plate is fixed side bar and lintel
Refer to the previous article, " When the mounting plate is first fixed ", for theposition of wall hole.
Fix to side bar and lintel a mounting bar, Which is separately sold, and then fastenthe plate to the fixed mounting bar.
Make a hole of Bmm in diameter,slightly descending to outside the wall.Install piping hole cover and seal itoff with putty after installation
(Section of wall hole) Piping hole pipe
Outdoor side
Thicknessof wall
Indoor side
Wall hole
Bmm
Indoor unit1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
145 60
70
Amm Bmm
150
HSU-09HC03/R2(DB)
HSU-18HC03/R2(DB)HSU-12HC03/R2(DB)
HSU-22HC03/R2(DB)6.35mm(1/4")
Haier air conditioner Edition: 1.0-070801
-104-
4.Connecting the indoor/outdoor Electric Cable
Removing the wiring coverRemove terminal cover at right bottom corner of indoorunit, then take off wiring cover by removing its screws.
Fixing the indoor unit bodyHang surely the unit body onto the upper notches of themounting plate. Move the body from side to side to verifyits secure fixing.In order to fix the body onto the mounting plate,hold upthe body aslant from the underside and then put it downperpendicularly.
Other direction pipingCut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe accordingto the position of wall hole. When bending, be careful not to crash pipes.Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulationof connecting part specially.
Left Left-rear pipingIn case of left side piping, cut away, with a nipper, the lid for left piping.In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rearpiping which is marked on heat insulation materials.1. Insert the drain hose into the dent of heat insulation materials of indoor unit.2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them.3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.
Lid for right piping
Lid for under piping pipe
Lid for left piping
Heat insulationmaterial
Drain hose
Piping
Indoor/outdoorelectric cable
Fix with adhesive tape
Drawing of pipeRear piping
Draw pipes and the drain hose, then fasten them with the adhesive tape
3.Installation of the Indoor UnitIndoor unitHaier air conditioner Edition: 1.0-070801
-105-
When connecting the cable after installing the indoor unit1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed.2. Pull out the cable on the front side, and connect the cable making a loop.
Insert the cable from the back side of the unit, then pull it out on the front side.Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.Pull the cable slightly to make sure the cables have been properly inserted and tightened.After the cable connection, never fail to fasten the connected cable with the wiring cover.
LN
{
Indoor unit
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect.1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F.2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.3. The wiring method should be in line with the local wiring standard.4. After installation, the power plug should be easily reached.5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm.
Indoor unitIndoor unit Outdoor unit
HSU-09HC03/R2(DB)
4G1.5mm2
Power cable: 3G1.5mm2
32
1
45
32
1
Power cable: 3G1.5mm2Indoor unit
4
Outdoor unit
4G1.5mm2
Outdoor unit
Connecting wiring:
Connecting wiring:
Connecting wiring:Connecting wiring:
HSU-22HC03/R2(DB)
HSU-12HC03/R2(DB)
HSU-18HC03/R2(DB)
{
LN
Haier air conditioner Edition: 1.0-070801
-106-
Apply refrigerant oil on half union and flare nut.
Drain hose
Outdoor unit1.Installation of Outdoor Unit
2.Connection of pipes
Install according to Drawing for the installation of indoor and outdoor units
To bend a pipe, give the roundness as large as possible not to crush the pipeConnecting the pipe of gas side first makes working easier.
Half union Flare nut
Spanner Torque wrench
3.ConnectionUse the same method on indoor unit. Loosenthe screws on terminal block and insert theplugs fully into terminal block, then tighten thescrews.Insert the cable according to terminal numberin the same manner as the indoor unit.
If wiring is not correct, proper operation cannot be carried out and controller may bedamaged.Fix the cable with a clamp.
4.Attaching Drain-Elbow If the drain-elbow is used, please attach it as figure.
Note: Only for heat pump unit.
Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.The standard pipe length is 5m. If it is over 5m, the function of the unit will be affected. If the pipe hasto be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerantmust be conducted by professional air conditioner engineer. Before adding additional refrigerant,perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then chargeadditional refrigerant.
Forced fastening without carefulcentering may damage thethreads and cause a leakage of gas.
Pipe Diameter Fastening torque
42 N.m
Gas side 15.88mm(5/8") 60 N.m
Liquid side 9.52mm(3/8")
Liquid side 6.35mm(1/4") 18N.m
Gas side 12.7mm(1/2") 55N.m
Haier air conditioner Edition: 1.0-070801
-107-
Outdoor unit6.Purging Method:To use vacuum pump
Detach the service port's cap of 3-way valve , thevalve rod's cap for 2-way valve and 3-way's, connectthe service port into the projection of charge hose(Iow) for gaugemanifold. Then connect the projectionof charge hose (center) for gaugemanifold intovacuum pump.
3-way valve
Gas Side
2-way valve
Service port cap
Gaugemanifold(for R410A)
Vacuum pump(for R410A)
Open
Close
Liquid Side
Open the handle at Iow in gaugemanifold, operatevacuum pump. If the scale-moves of gause (Iow)reach vacuum condition in a moment, check again.
Vacuumize for over 15min. And check the level gaugewhich should read -0.1 MPa (-76 cm Hg) at Iowpressure side. After the completion of vacuumizing,close the handle 'Lo' in gaugemanifold and stop theoperation of the vacuum pump.Check the condition of the scale and hold it for 1-2min.If the scale-moves back in spite of tightening, makeflaring work again, the return to the beginning of .
Open the valve rod for the 2-way valve to an angle ofanticlockwise 90 degrees.After 6 seconds, close the 2-way valve and make theinspection of gas leakage.
No gas leakage?
In case of gas leakage, tightenparts of pipe connection. Ifleakage stops, then proceedsteps.
Detach the charge hose from the service port, open2-way valve and 3-way valve . Turn the valve rodanticlockwise until hitting lightly.
To prevent the gas leakage, turn the service port'scap, the valve rod's cap for 2-way valve and 3-way'sa little more than the point where the torque increasessuddenly.
After attaching the each caps, check the gas leakagearound the caps.
CAUTION:1.If the refrigerant of the air conditioner leaks, it is necessary to discharge all the refrigerant. Vacuumize first, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate.
2.Please do not let other cooling medium, except specified one (R410A), or air enter into the cooling circulation system. Otherwise, there will be abnormal high pressure in the system to make it crack and lead to personal injuries.
If it does not stop gas leakage, dischargewhole refrigerants from the service port.After flaring work again and vacuumize,fill up prescribed refrigerant from the gascylinder.
Anti countercurrent joint
7
6
1
2
3
1
3
4
5
6
7
8
Open90
O
Valve rod cap
Valve rod cap7
7
3-way valve
2-way valve
3-way valve
2-way valve
3-way valve
2-way valve
2-way valve
3-way valve
2-way valve
3-way valve
Gas SideLiquid Side
6.35mm(1/4")
12.7mm(1/2")
HSU-22HC03/R2(DB)HSU-18HC03/R2(DB)
HSU-09HC03/R2(DB)HSU-12HC03/R2(DB)
Tube(for R410A)
Haier air conditioner Edition: 1.0-070801
-108-
It becomes high midway. The end is immersedin water.
It waves. The gap with the groundis too small
Less than 5cm
There is the bad smellfrom a ditch
1.Power Source Installation
2.Cutting and Flaring Work of Piping
3.On Drainage
Check for Installation and Test Run
Check Items for Test Run
The power source must be exclusively used for air conditioner. (Over I0A)In the case of installing an air conditioner in a moist place, please install anearth leakage breaker.For installation in other places, use a circuit breaker as far as possible.
Pipe cutting is carried out with a pipe cutter and burs must be removed.After inserting the flare nut, flaring work is carried out.
Please install the drain hose so as to be downward slope without fail.Please don't do the drainage as shown below.
Please pour water in the drain pan of the indoor unit, and confirm that drainage iscarried out surely to outdoor.In case that the attached drain hose is in a room, please apply heat insulationto it without fail.
Please kindly explain to our customers how to operate through the instruction manual.
Gas leak from pipe connecting?Are the connecting wirings ofindoor and outdoor firmly insertedto the terminal block?Is the connecting wiring of indoorand outdoor firmly fixed?
Is drainage securely carried out?Is the earth line securelyconnected?Is the indoor unit securely fixed?Is power source voltage abidedby the code?Is there any noise?
Put check mark in boxes
Is the lamp normally lighting?Are cooling and heating (whenin heat pump) performed normally?Is the operation of room temperatureregulator normal?
Flare tooling die
Liquid side
Gas side
Pipe diameter Size A (mm)6.35mm(1/4")9.52mm(3/8")
15.88mm(5/8")
0.8~1.51.0~1.8
1.4~2.2
Liquid side
Correct Incorrect
Lean Damage of flare Crack Partial Too outside
Gas side
12.7mm(1/2") 1.2~2.0
Haier air conditioner Edition: 1.0-070801
HSU-09,12,18,22HC03/R2(DB) The End