2020 High Wall SplitProduct Training

Haier Air Conditioning

Page 2: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Training Objectives

By the end of this training, you will:

• Have been introduced to the Haier Flexis Series.

• Be able to interpret and identify a Haier Aircon Flexis by their model number.

• Be able to interpret a Haier Aircon serial number and know where the serial plate is located.

• Be able to locate, understand and translate dimension and installation information.

• Have a basic understanding of system functions and specifications.

• Have a basic understanding of the error codes.

• Have a basic understanding of the electrical layout and specifics of sensors and type of compressors F&P Haier models use.

• Have an understanding of common repairs.

Page 3: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

3

1• Flexis / MRVs

2• Application

3.

• Installation Easy Install/Maintenance4

• Remote Control & Functions

5• DRC & Wi-Fi

6• Technical Hints

7 • MRVs Installation

8• Questions

Page 4: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

F Series

Flexis

Flexis AC High Wall

Indoor AS35FBBHRAAS53FEBHRAAS71FEBHRAAS82FFAHRA

Outdoor 1U35JACFRA1U53RABFRA1U71FEBHRA1U82SAAFRA

Page 5: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Remote Control YR-HQ Flexis

1. ECO SENSOR button (Flexis) Eco Pilot button (Dawn)

2. DRY button - Used to set DRY operation.

3. COOL button - Used to set COOL operation.

4. TEMP button - used to change setting Temperature

5. ON / OFF button

6. Display of each function status

7. Operation mode display

8. WIFI and CLOCK display

9. TEMP display

10. Humidity display

11. FAN SPEED display

12. SWING display - Swing up/down display, swing left/right display

13. TIMER ON display TIMER OFF display CLOCK display

14. FAN button

15. QUIET button

16. HEAT button

17. SELF CLEAN button

Flexis Controls

Page 6: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Remote Control YR-HQ

18. TIMER button

19. CLOCK button

20. 10 ºC button special heating set function: 10 degree heating maintaining (valuable for RS)

21. HEALTH button

22. SMART button Used to set SMART operation. (This function is unavailable on some models)

23. SWING up/down button

24. SWING left/right button

25. SLEEP button

26. HEALTH AIRFLOW button

27. LIGHT button Control off & on lightening of the indoor LED display board.

28. CODE button A-b yard

29. APPLY button

30. TURBO button

Flexis Controls

Page 7: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Domestic Air ConditionerBasics

• Air conditioning is the process whereby the condition of air, its temperature and moisture content, is changed.

• Comfort is subjective, however most people (90%), are comfortable when the air temperature is between 18-22°C and the humidity is between 40-65%.

• This known as the comfort zone or zone of human comfort

Temperature Comfort

Page 8: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Understand your location

• Good air circulation is imperative to good unit performance and energy efficiency

• Correct Outdoor unit air clearances improve performance and reduce noise

• Units need to be mounted where they can be accessed for service

• Correct wall brackets for the unit size need to fitted or ventilation and safety can be compromised

Haier AC Installation Dimensions

Page 9: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Installation Dimensions

IndoorOutdoor

Minimum Requirements

Page 10: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

R32 Refrigerant

Now used in Flexis Models, R32 has similar working pressure to R410A around 12-26 Bar (174-377 Psi)

R32 has better capability to exchange heat-load than R410A , it produces a higher capacity than R410A therefore is more efficient.

Due to these efficiencies,R32 use 30% less refrigerant charge to produce an equal load capacity.

Flexis Installation

Page 11: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Modern type of flaring tool

• Flare joint must be made using the

correct tooling

• Modern flaring kit allows the flare ring to

be formed at a set “torque”

• The tightness is pre-set & does not over

stress the pipe work

• Be careful to remove the burrs by using a

deburring tool from the edges of the

pipes before flaring

Installation

Deburring Tool

Page 12: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

• Flare joint tightened with a torque spanner

• Avoid over stressing the joint( double spanner)

Avoid stress

Installation

Correct torque must be applied

COPPER

PIPE OD

(mm)

FLARE

SIZE (mm)

FLARE

NUT OD

(mm)

TORQUE

N/m

6.35 ¼’ 8.7 – 9.1 17 14 – 18

9.52 3/8’ 12.8 – 13.2 22 34 – 42

12.7 ½’ 16.2 – 16.6 26 34 – 42

15.88 5/8’ 19.3 – 19.7 36 69 - 82

Page 13: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

HVAC TOOLS

Equipment Model Number Please Circle

Recovery Unit Yes No

Nitrogen Regulator Yes No

Vac Pump Yes No

Vacustat/ Torr Gauge Yes No

Data Logger Yes No

Oxy & Acetylene Yes No

Anemometer and Air hood Yes No

Recovery Bottle Yes No

Refrigeration Gauges 410A/R32 Yes No

Bottle of Clean 410A/R32 Yes No

Amp/Tong Tester Yes No

Multi Meter Digital & Analogue Yes No

Digital Thermometer Yes No

Does your company have the following equipment in each Service Vehicle?

Electronic Hand-held leak detectorthat detects a wide range of refrigerants, such as CFC, HFC,HCFC and HFO refrigerants 1234yf and R32.

Page 14: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

It is most important that Oxygen Free Nitrogen (OFN) is

continually purged through the pipework when welding

• Purged = 3-5psig above atmospheric pressure

During brazing process, the inside of the copper

produces “Carbon deposits”

Installation

Page 15: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

• Pressure test with nitrogen to establish basic system seal

• Release pressure and connect vacuum pump

• System must hold a vacuum to at least 500 microns (equivalent to

99.9% vacuum)

• Always use a quality vacuum pump

• Check and change oil on a regular basis

• Check vacuum with Torr gauge or vacustat positioned as far from

vacuum pump as possible

Installation

Page 16: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Before Putting system into service the unit must undergo the following tests

Strength test

Leakage test

note: only use dry nitrogen

3.0 Bar - Minimum 3 min

15.0 Bar - Minimum 3 min

32.0 Bar - Minimum 3 min

41.5 Bar - Strength test for a period of time acceptable to show any signs of deformation of pipe work

33.0 Bar - Minimum 5 minutes

Installation (MRV)

Page 17: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

0

10

20

30

40

50

60

-20 -10 0 10 20 30 40

evaporative temp

To

rr

In ambient conditions of 10°c moisture will not boil off until 10 Torr is achieved

0

10

20

30

40

50

60

-20 -10 0 10 20 30 40

evaporative temp

To

rr

Or below 500 micron with vacustat

Installation

Page 18: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Flexis Easy Installation

18

Time saved on Installation

With the help of 1. Improved mounting plate ,2. L-shaped Easy Support Clip design,3. Snap-in design 4. Left/right optional drainage pipe design,

Designed with easier installing in mind

Page 19: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Flexis Easy Maintenance

19

With the help of 5. External emergency button design,6. The pluggable computer board design 7. Easy & quick removal motor design

Easier maintenance.

Time saved on Maintenance

Page 20: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Flexis Easy Installation .

20

Advanced technology of mounting plate improvement to make AC easier installing.

Mounting Plate Improvement

Measurements and space for tape line on mounting plate, it is more convenient for quick positioning to save installation time.

It is easier to fix the tape.

Page 21: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

21

Flexis L-shaped Easy Support Clip design

Advanced technology of L-shaped easy support clip, larger operating space expanded by 48% , easier pipe connection without auxiliary tools to support the machine.

2 L-shaped Easy Support Clip

It is more convenient for installation by extending space(nearly 168mm) with additional support clip.

Expanded 48%

Page 22: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

22

Flexis Snap-in design

4.With the Snap-in design , remove pinch plate without screwdriver to make AC easier installing.

Snap-in design

Removing the Snap-On decoration plate will allow installers to easier connectpiping and wires.

Step2: pull down the slot with

finger

Page 23: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

23

Flexis Left/right optional drainage pipe design

2-Way Drain Pipe Design

The indoor unit offers the possibility of left or right pipingdirection, easy for installation.

With 2-way piping design, there is no worry about the position where the AC is installed. You can change the drain pipe position by one screw

3.Advanced technology of 2-Way Drain, getting rid of some of the installation environment restrictions, to make AC easier installing.

Page 24: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

24

Flexis the pluggable computer board design

Step 1: Open the fascia and remove the screw from the electrical cover.

Step 2:Remove the PCB through the panel

Quick & Easy Repair PCB

PCB removal and maintenance just 2 steps without disassembling evaporator.

Page 25: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Haier AC Installation Electrical

Choose your interconnecting cables carefully

1.5mm Orange Four Core or Flat Four Core TPS: Active and Comms wires side by side and twist creating magnetic interference down the CommsLine. ***Please do not use these cables***

Only use 2.5mm 3 Wire TPS and Separate 1.5mm Single 1.5mm Double Insulated Comms Wire

Secure your Outer Insulation

Page 26: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

All units Interconnection Wiring

• All Haier A/C Wiring is the same for the interconnection at both indoor and outdoor units

• 1 = Neutral 2=Active (Live) 3= Comms 4= Earth

Haier AC Installation Electrical

Page 27: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

27

Flexis easy &quick required motor design

6 Quick & Easy Repair Motor

Normal :9 Tedious stepsa. Pump system down. b. Release the connecting pipe

and remove the indoor unit.c. Open the panel and remove

the coverd. Remove electrical cabinet. e. Remove the evaporator. f. Disassemble the screw of fan

and motor. g. Remove the motor bracket. h. Take out the motor.

Motor removal just 5 steps without disassembling evaporator.

Step 1: Open the faccia and remove the cover

Step2: Disassemble the electrical box, remove the fixed screw of the motor and fan

Step3:Remove the 2 screws of the motor bracket.

Step4:Remove the two brackets on the right side of the motor.

Step 5: Remove the motor

Promotion 44%

Page 28: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

F Series Serial Number and Model

Indoor under the Front cover, Outdoor the same as other models

Model & Serial Number locations

Page 29: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Technical Service Hints

F Series Indoor PCB ServiceAccess to PCB without removing outer cover of outdoor unit.Earth terminal screw on indoor coil.

Page 30: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Technical Install Hints

• The indoor unit is shipped from the factory with a small nitrogen

charge in it. The pressure will release when the transport caps

are removed from the flare connections.

• Both of the brass flare nuts for the indoor connections are in the

same packaging as the remote control.

• Remove the foam stripes around the blower wheel before

starting 5.3kW & 7.1kW indoor units.

• Follow the electrical connection labels. Haier terminal blocks are

labelled 1 Neutral, 2 Line, 3 Comms, and 4 Earth. You may be used to

seeing Line, Neutral, Comms, and Earth.

Page 31: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Technical Install Hints

• Flexis series the hole is already drilled out.

• Rubber feet for condensor are in packaging under

condenser.

• All models are DRED enabled. Connection cable is a

data cable with RJ45 connector and is accessible at

condensor terminal blocks.

Page 32: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Technical Install Hints

• All Flexis indoor PCBs are the same part number

for that series of product. The units capacity is set

via the Dip Switches

• F Series H0011800593B.

• SW2 on the PCB needs to be set to the correct

indoor capacity when changing from original part.

• First indication they are incorrectly set may be

reverse operation of the louvre or you may get a

communications fault (E7)

Indoor Dipswitch settings for 26 Indoor Dipswitch settings for 35

3 OFF 3 OFF

4 OFF 4 ON

Indoor Dipswitch settings for 53 Indoor Dipswitch settings for 71

3 ON 3 ON

4 OFF 4 ON

Page 33: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Technical Service Hints

• Cut only J2 on Flexis series units ,only when

replacing a faulty indoor PCB.

Display Bridges

Page 34: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Demand Response Control

DEMAND RESPONSE CONTROL (DRC)

For models fitted with Demand Response Control

Demand response Control provides a method by which a controlling authority, most likely a power supply company, can limit the amount of power that an air conditioner can consume in comparison to its nominal full load power consumption. The aim is to reduce overall power consumption to the supply network at critical peak load times. A command is passed down the power supply which triggers a response. Not dissimilar to what some power companies do when controlling peak demand for electric water heaters in some countries.

DRC is capable of demanding three different levels of response from the air conditioner, identified as DRM1, DRM2 and DRM3.DRM1 which is 'compressor off' is the minimum required to meet the Australian New Zealand standard AS4755.3.1.DRM2 must not exceed 50% of Capacity kWDRM3 must not exceed 75% of Capacity kW

If DRC is being used by your power supplier your product will show one of the three responses in the LED display as follows

d1: Indicates that your supplier has switched off your unit due to high power demand on the local net workd2: Indicates that your supplier has reduced the capacity of your unit to 50% due to high power demand on the local net workd3: Indicates that your supplier has reduced the capacity of your product to 75% due to high power demand on the local net work

Important please note if any one of the LED indicators shown above are displayed on your products LED display DO NOT call Haier Customer Service until you have checked with your power supplier to confirm if they have activated their DRC device.

DREDS device is connected to the RJ485 plug to control

If after conferring with your power supplier you believe your product requires service please call Haier Customer Service on New Zealand 0800 424 372

Page 35: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Product Identification

Serial Number

Page 36: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Louvres

F Series – Vertical and Horizontal Movement

Haier DAC Functions

Page 37: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Wi-Fi Functions

WiFi

Page 38: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Wi-Fi Functions

WiFi

Page 39: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Basic control and monitoring – Turn on/off, Mode, Setting temperature , Room temperature , Fan speed and Louver swing.

STATUS of AC –Turn on /Turn off

MODE –Auto Cool Heat Fan Dry

SETTING TEMP. –Operating range from 16-30℃/60-86℉

FAN SPEED–High Mid Low Auto

ROOM TEMP. –Display range from 0-55℃/32-130℉

Wi-Fi Functions

Wi-Fi

Page 40: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

9. ECO - SENSOR

Two technologies 1. Follow and avoid2. Occupied/unoccupied.

Human Sensor Energy-saving Tech.

1. Forget to turn off the AC when no one is in the room, cause energy waste;2. Airflow directly to people when cooling, which is uncomfortable and may cause disease;3. Airflow may direct to no-people area, cause energy waist.

User’s

Point’s

Info1. Two-area Human Sensor Integrated module;2. Sensed angle – 120°3. Sensed distance – 5m4. Two sensed zones (1 & 2)

Benefits

for

Users:

Enables energy saving operations

when the room is unoccupied for 20

minutes:

Two-area sensor, avoid human when cooling

and direct to human when heating. More

comfortable & energy-saving

Heathy Airflow Mode

F Human Sensor Technologies——Angle: 140° within 2 meters(120° out of 2 meters);Distance should be 8 meters(5 meters tested)

Flexis Sensor

Page 41: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Self-clean

41

With regular use of self-clean technology, there is minimal need to clean the AC evaporator

Time saved on Cleaning

Page 42: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Self-clean

42

Self Clean (evaporator self-cleaning) is applicable for both NSV/NFV Series inverter models

Conclusion: Self Clean is the patent technology for Haier which can clean the evaporator.

This function can help end-user to save the cleaning cost with 99.9% anti-bacteria rate.

Pains of end-user

If cleaning .

If not cleaning .

It takes twice cleaning a year and cost

Major benefits to end-user

1) saving the cleaning fee

Bacterial, virus will spread into the airflow .

For reference: The cooling performance will reduce approximately by 10%~15% because of dirty evaporator .

3) Cooling performance not affected by dirty evaporator 2) Healthy air, 99.9% anti-bacteria rate

After periodic use, dust will be accumulated on the surface of evaporator, which is easily breeding bacteria and virus.

Page 43: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

43

Self-clean

Press the Self Clean Button on remote controller

CL (short for clean) will display on the front panel

The evaporator will freeze After time the unit will cause ice to melt and wash away dirt covered on the surface of the evaporator

Whole process 21 Minutes

Self Clean Process

Bacteria killing at the same time

Nano silver anti-virus material on the surface of aluminum can effectively kill 99.9% bacteria and virus at the same time

Recommended Frequency

Recommend to use Self Clean once a week to keep evaporator clean

Note: During the Self Clean process, the unit stops cooling performance and the customer will not feel cold air blowing from the system.

Page 44: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Technical Functions

Emergency Button

Operation under emergency mode

Room temp Mode Set temp Fan mode

Higher than 23℃ Cooling 26℃ Auto

Lower than 23℃ Heating 23℃ Auto

1. When remote controller is lost, it is possible to use this button.2. Press the button, hear “Pi” sound, then the unit will start.3. In this condition, the unit will choose appropriate mode automatically

4. Press this button and hold down for 5 seconds, until hear two “Pi” “Pi” sound.5. In this condition, the unit running at cooling mode with high fan speed.6. Keep pressing the emergency button for 15 seconds and then release. There will

be “Pi” sound 3 times. The display on the indoor unit will then show the last error.

External emergency button run the machine without opening the

cover panel.

Page 45: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

MRV S” 9kW Cooling / 10kW Heating

Page 46: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

MRV S” 9kW Cooling 10kW Heating

High Wall Model AS302MNERA

Remote Control YR-HD

Wi-Fi

Page 47: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

MRV S “ Outdoor Unit

Page 48: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

MRV S” Outdoor / Indoor Electrical Connection

Power (240V) Connections

Control (P & Q) connections to indoor units

3=P4=Q

Power (240V) Connections

Page 49: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Outdoor Unit: Diagnostic PCB

Status LED

Manual function and mode selection switches

Connection for laptop analyzer

Page 50: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Start Up

1. Confirm the number of ID units, OD unit type, and supply voltage are correct

2. The compressor has a 5-minute delay feature

3. ID units cannot run in both cooling and heating at the same time

4. Automatic defrost usually lasts from 2-10 minutes; indoor fans slow or stop

5. Only operate the system within the prescribed temperature range

6. If the humidity exceeds 80%, the indoor units may blow moisture into the room

7. If the “restart” function is enabled, the system will resume the last state following a power failure

8. Add labels in the disconnect boxes to identify connected ID and OD units when multiple units are installed

Page 51: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Start Up

Looking for ID units Discovered ID units

Once indoor is found set BM1 to on

Page 52: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

Questions?

Page 53: Haier Air Conditioning · 2020. 11. 25. · Haier AC Installation Electrical Choose your interconnecting cables carefully 1.5mm Orange Four Core or Flat Four Core TPS: Active and

53

Thank you for attending

Haier Air Conditioning