24
Consumer Unit 1 Product Range Summary 2 enclosed distribution board p.2 consumer unit p.3 consumer unit & consumer unit split bar p.4 enclosures p.5 invicta 63 - MCB distribution boards p.6 - 7 invicta 63 - TP & N distribution boards p.8 - 9 U series - invicta 125 panel board system p.10-12 U series - invicta 250 panel board system p.13 enclosed fuse combination switches & switch disconnectors p.14 enclosed fuse combination switches 32-630A p.15 switch disconnectors p.16 IP65 switch disconnectors TP &N 20-125A

HAGER ENCLOSURES - Cat HK02 Enclosures

Embed Size (px)

Citation preview

Consumer Unit

1

Product Range Summary

2

enclosed distribution board

p.2 consumer unit

p.3 consumer unit & consumer unit split bar

p.4 enclosures

p.5 invicta 63 - MCB distribution boards

p.6 - 7 invicta 63 - TP & N distribution boards

p.8 - 9 U series - invicta 125 panel board system

p.10-12 U series - invicta 250 panel board system

p.13 enclosed fuse combination switches &

switch disconnectors

p.14 enclosed fuse combination switches 32-630A

p.15 switch disconnectors

p.16 IP65 switch disconnectors TP &N 20-125A

consumer unit

2

The metal clad range of consumer units are availablewith a fixed and split load 100Afully tinned busbar. The unitsfeature either a transparent ormetal cover, protecting the

devices, and can be supplied aseither a surface or flush mounted option. The 2 poleincomer options can be either aswitch disconnector, RCCB orMCB. The outgoing devices are

either MCB’s or single / doublemodules RCBO’s. Blank insertsare available to cover unusedways. All consumer units havestandard size knockouts and aredelivered with earth bar, neutral

bar, busbar shroud and label kit.The units have been fully ASTAtested and comply withBSEN60439-3 (AnnexZA).

Neutral terminal

• fully tinned

Outgoing devices

• mcb’s

• 1 module rcbo’s

• 2 modules rcbo’s

Fixed busbar

• fully tinned

Knock outs

• for standard size conduits

Earth terminal• fully tinned

• extra ways to accept

bonding conductor

Domed holes

• for ease of installation

Cover• transparent or metal

consumer unit

3

consumer unit split bar

switch disconnector Total ways pack cat (isolator) rating qty. ref.

63/100A incoming 4 ways 1 HE04SN

6 ways 1 HE06SN

8 ways 1 HE08SN

10 ways 1 HE10SN

12 ways 1 HE12SN

14 ways 1 HE14SN

16 ways 1 HE16SN

18 ways 1 HE18SN

• other models available on request

switch disconnector Total ways pack cat (isolator) rating qty. ref.

63/100A incoming 4+2 ways 1 HE42SN

& 40/63/80A incoming DP RCD 5+2 ways 1 HE52SN

6+2 ways 1 HE62SN

5+3 ways 1 HE53SN

6+3 ways 1 HE63SN

7+3 ways 1 HE73SN

8+4 ways 1 HE84SN

• other models available on request

descriptionThis range of consumer units arespecially designed for the HongKong Market. They are easy toinstall and offer the option of aswitch disconnector or RCCBincoming device or a switch dis-connector and an RCCB in thesplit bar version. They are robustand versatile and can incorpo-rate both MCB & RCBO. Unitincludes both neutral and earth.

standards: BSEN 60439-3(BS 5486 pt 13)

surface mountingenclosures w/doors

SP+N: 1 row 4 -18 ways

Split bar: 1 row (4+2 – 8+4 ways)

Enclosure and door manufactured from steel.1.2 mm thick.

delivered with earth and neutral bars

HE06SN

HE53SN

enclosures

4

designation pack cat qty. ref.

1 row / 1 way 1 VT01E

1 row / 2 ways 1 VT02E

1 row / 4 ways 1 VTO4E

1 row / 6 ways 1 VT06E

1 row / 8 ways 1 VT08E

1 row /10 ways 1 VT10E

1 row /12 ways 1 VT12E

2 row /14 ways 1 VT14E

2 row /16 ways 1 VT16E

• other models available on request

surface mountingenclosures without doorcomplete with din rail1 row 4-16 ways

Enclosure manufactured from1.2mm steel.

delivered with earth and neutral bars

VT06E

5

invicta 63 - MCB distribution boards

description:

The invicta 63 metal clad rangeof three phase and neutral distribution boards are availablewith a fixed load or split loadpan assembly. They all have afully flush fitted metal door witha "slam" type catch. All boardsare delivered with both Neutraland Earth bars fitted and the

neutral is designed to wraparound the incoming device toensure that extra wiring space isavailable for the outgoingdevices. The incoming devicemust be selected and fitted bythe installer. The top and bottomgland plates are removable andalso include knock-outs to suitstandard size conduits. The pan

assembly is fully shrouded andthe busbars are one piece indesign, this ensures that no "hotspots" can occur as there are nomechanical joints. The boardshave been designed and independently ASTA tested toBSEN 60439-1 & 3.

Removable gland plates (top / bottom)

Outgoing circuits• Fit with SP + TP MCB’s• and 1 module RCBO’s

Incoming links

Incoming devices• Switch disconnectors• MCCB’s• RCCB’s

Safety shroud

Robust powder coated sheetsteel enclosure

Totally enclosed, busbar system rated at 200A• colour coded circuit designation

6

invicta 63 TP&N distribution boards -200A incoming, 63A outgoing

designation number of pack cat.

TP ways qty. ref.

6 1 JD06P

12 1 JD12P

18 1 JD18P

24 1 JD24P

4 1 JK04PC

6 1 JK06PC

8 1 JK08PC

10 1 JK10PC

12 1 JK12PC

16 1 JK16PC

4 1 JK04FC

6 1 JK06FC

8 1 JK08FC

10 1 JK10FC

12 1 JK12FC

16 1 JK16FC

4 1 JK04GC

6 1 JK06GC

8 1 JK08GC

10 1 JK10GC

12 1 JK12GC

16 1 JK16GC

TP & N for DP (incoming 200Adirect terminal)

TP & N (incoming 200A directterminal)

TP & N (space for 63/100A TPAI Switch)

TP & N (space for 200A TP AISwitch)

JK04FC

invicta 63 TP&N distribution boards -200A incoming, 63A outgoing

7

designation number of cat.

TP ways ref.

2 + 2 ways JK22PC

4 + 2 ways JK42PC

6 + 2 ways JK62PC

8 + 2 ways JK82PC

10 + 2 ways JK92PC

4 + 4 ways JK44PC

6 + 4 ways JK64PC

8 + 4 ways JK84PC

10 + 4 ways JK94PC

12 + 4 ways JK24PC

6 + 6 ways JK66PC

8 + 6 ways JK86PC

10 + 6 ways JK96PC

2 + 2 ways JS22PC

4 + 2 ways JS42PC

6 + 2 ways JS62PC

8 + 2 ways JS82PC

10 + 2 ways JS92PC

4 + 4 ways JS44PC

6 + 4 ways JS64PC

8 + 4 ways JS84PC

10 + 4 ways JS94PC

12 + 4 ways JS14PC

6 + 6 ways JS66PC

8 + 6 ways JS86PC

10 + 6 ways JS96PC

TP & N split Bar (space for 63/100ATP AI switch & 40/63A 4P RCD)

TP & N split bar (space for 200A TPAI switch & 40/63A 4P RCD)

JK42PC

8

U series - invicta 125 panel board system -400 A incoming, 125 A outgoing

The metal clad range of Invicta125 three phase and neutralMCCB distribution boards withincoming arrangements. They allhave a fully flush fitted half metaldoor, which ensures the incomeris accessible at all times, with aquick release door catch. Theboards are delivered with bothNeutral and Earth bars fitted and

ample wiring space is providedaround both the outgoing andincoming devices to make con-nection easy. All busbars, neu-trals & earth bars are fullytinned. The incoming & outgoing devices must beselected and fitted by theinstaller. The top and bottomgland plates are removable to

help when connecting to trunking systems. The panassembly is fully shrouded andthe busbars are one piece indesign, this ensures that no "hotspots" can occur as there are nomechanical joints. The boardsare ASTA certified have beendesigned and independentlytested BSEN 60439-1 & 3.

All MCCB’s comply withBSEN60947-2 and non-automatic MCCB’s withBSEN60947-3.

Removable gland plates• top• bottom

Numbered individualtinned earth bars

Tinned neutral bar

Shrouding oflive connection

Totally enclosed,busbar systemrated at 250A

Robust powdercoated sheetsteel enclosure

Half door

Quick release catch

Colour coded circuit designation

SP & TP outgoing MCCBs

Choice of incoming kits• 250A Switch Disconnector• 250 A or 400A MCCB

9

U series - invicta 125 panel board system -400 A incoming, 125 A outgoing

no. of pack cat.

TP Ways qty. ref.

direct connection terminals (included incoming kits)

4 X 125A outgoing ways 1 JN 04UB

6 X 125A outgoing ways 1 JN 06UB

8 X 125A outgoing ways 1 JN 08UB

10 X 125A outgoing ways 1 JN 10UB

12 X 125A outgoing ways 1 JN 12UB

16 X 125A outgoing ways 1 JN 16UB

with links and shroud to accept a 250A main switch (included incoming kits)

4 X 125A outgoing ways 1 JN 04US

6 X 125A outgoing ways 1 JN 06US

8 X 125A outgoing ways 1 JN 08US

10 X 125A outgoing ways 1 JN 10US

12 X 125A outgoing ways 1 JN 12US

16 X 125A outgoing ways 1 JN 16US

with Links and Shroud to accept a 250A MCCB (included incoming kits)

4 X 125A outgoing ways 1 JN 04UC

6 X 125A outgoing ways 1 JN 06UC

8 X 125A outgoing ways 1 JN 08UC

10 X 125A outgoing ways 1 JN 10UC

12 X 125A outgoing ways 1 JN 12UC

16 X 125A outgoing ways 1 JN 16UC

with Links and Shroud to accept a 400A MCCB (included incoming kits)

4 X 125A outgoing ways 1 JN 04UM

6 X 125A outgoing ways 1 JN 06UM

8 X 125A outgoing ways 1 JN 08UM

10 X 125A outgoing ways 1 JN 10UM

12 X 125A outgoing ways 1 JN 12UM

16 X 125A outgoing ways 1 JN 16UM

extension Box for Invicta 125

extension box for cable 1 JN 01UB

extension box for din rail 1 JN 01UD

description:Three Phase and Neutral Type BMCCB Distribution Boards areavailable in 4, 6, 8, 10, 12 &16triple pole outgoing ways.Incomers can be selected fromMCCB, non-automatic MCCB orswitch disconnector. All boardsare delivered with tinned Neutral& Earth Bars, relevant link kitsand protective shrouds. Exten-sion boxes are available forinstalling current transformers,etc. These boxes can also beused for obtaining extra cable

space. Delivered with circuitidentification label & wallet.

electrical Specification:Tested and complies to the relevant parts of BSEN 60439-1 & 3:Electrical Supply: 415V ~ Maximum Continuous Rating:400AThe rating of the board is inaccord with the incoming device.Short time withstand:40kA for 1s.

devices Incoming:400A MCCB(h400frame)250A MCCB (h250frame) 250A Non Auto MCCB250A Switch Disconnector Direct Connection

Outgoing:SP MCCB’s (h125)TP MCCB’s (h125)

• for the information of dimensionsee page 21

JN04UB

JN04US

JN04UM

10

U series - invicta 250 panel board system -800A incoming, 125A/ 250A outgoing

description:The metal clad range of Invicta250 three phase and neutralMCCB distribution boards areavailable with a choice of 3P and4P incoming arrangements.They have a fully flush fitted halfmetal door, which ensures theincomer is accessible at alltimes, and quick release doorcatch. The boards are delivered

with both Neutral and Earth barsfitted and ample wiring space isprovided around both the outgoing and incoming devicesto make connection easy. Theincoming & outgoing devicesmust be selected and fitted bythe installer. The top and bottomgland plates are removable tohelp when connecting to trunking systems. The pan

assembly is fully shrouded andthe busbars are one piece indesign, this ensures that no “hotspots” can occur as there are nomechanical joints. Extensionboxes are available and shouldbe used wherever extra cablespace is needed. The boardshave been designed and independently tested to BSEN 60439-1.

Removable gland plates• top• bottom

Individual tinned earthbars for ease of cabling

Totally enclosed,tinned busbar systemrated at 800A

Robust powdercoated sheet steel

Colour coded circuitdesignation

Outgoing MCCBs

Tinned neutral bar

Choice of incoming kits• 400 A MCCB (h630 frame)• 630 A MCCB• 800 A MCCB

Quick releasedoor lock

Shrouding oflive connection

11

U series - invicta 250 panel board system max 800A incoming, 125/250A outgoing

no of pack cat.

TP Ways qty. ref.

direct connection terminals (included incoming kits)

6 X 125A outgoing Ways 1 JF 06UB

8 X 125A outgoing Ways 1 JF 08UB

10 X 125A outgoing Ways 1 JF 10UB

12 X 125A outgoing Ways 1 JF 12UB

16 X 125A outgoing Ways 1 JF 16UB

2 X 250A + 2 X 125A outgoing Ways 1 JF 24UB

2 X 250A + 4 X 125A outgoing Ways 1 JF 26UB

2 X 250A + 6 X 125A outgoing Ways 1 JF 28UB

2 X 250A + 8 X 125A outgoing Ways 1 JF 20UB

2 X 250A +10 X 125A outgoing Ways 1 JF 22UB

4 X 250A outgoing Ways 1 JF 41UB

4 X 250A + 2 X 125A outgoing Ways 1 JF 46UB

4 X 250A + 4 X 125A outgoing Ways 1 JF 48UB

4 X 250A + 6 X 125A outgoing Ways 1 JF 40UB

4 X 250A + 8 X 125A outgoing Ways 1 JF 42UB

6 X 250 outgoing Ways 1 JF 61UB

* delivered with protective shroud

no of pack cat.

TP Ways qty. ref.

with position for a 400A MCCB (included incoming kits)

6 X 125A outgoing Ways 1 JF 06UF

8 X 125A outgoing Ways 1 JF 08UF

10 X 125A outgoing Ways 1 JF 10UF

12 X 125A outgoing Ways 1 JF 12UF

16 X 125A outgoing Ways 1 JF 16UF

2 X 250A + 2 X 125A outgoing Ways 1 JF 24UF

2 X 250A + 4 X 125A outgoing Ways 1 JF 26UF

2 X 250A + 6 X 125A outgoing Ways 1 JF 28UF

2 X 250A + 8 X 125A outgoing Ways 1 JF 20UF

2 X 250A +10 X 125A outgoing Ways 1 JF 22UF

4 X 250A outgoing Ways 1 JF 41UF

4 X 250A + 2 X 125A outgoing Ways 1 JF 46UF

4 X 250A + 4 X 125A outgoing Ways 1 JF 48UF

4 X 250A + 6 X 125A outgoing Ways 1 JF 40UF

4 X 250A + 8 X 125A outgoing Ways 1 JF 42UF

6 X 250 outgoing Ways 1 JF 61UF

* delivered with protective shroud

description:

Three Phase and Neutral Type BMCCB Distribution Boards are available in 4, 6, 8, 10, 12 & 16triple pole outgoing ways.Incomers can be selected fromMCCB, non-automatic MCCB orswitch disconnector. All boardsare delivered with both fullytinned Neutral & Earth Bars, rele-vant link kits and protectiveshrouds. Extension boxes areavailable for installing currenttransformers, etc. These boxes

can also be used for obtainingextra cable space. The correct incoming connection kitmust be selected to suit theincoming device.

electrical Specification:Tested and complies to the relevant parts of BSEN 60439-1:Electrical Supply: 415V ~Maximum Continuous Rating:800A. The rating of the board isin accord with the incomingdevice.

Short time Withstand:40kA for 1s.

mechanical specification:Protection Category IP 31Material 1.5mm CR4 SteelPowder Coated RAL 9001

devicesIncoming:400A MCCB cable lug (h630 frame) 630A MCCB (cable lug) (h630frame) 630A Non Auto MCCB

(cable lug) (h630 frame) 800A MCCB (cable lug or flatbar) (h800 frame) 800A Non Auto MCCB (cable lug or flat bar) (h800 frame)

Outgoing:SP MCCB’s (h125, h250 frame)TP MCCB’s (h125, h250 frame)Extension boxes Incomer connection kit

• for the information of dimensionsee page 21

JF06UB

12

U series - invicta 250 panel board system -max 800A incoming, 125/250A outgoing

JF06UM

extension box for cable 1 JF 01UB∆ extension box for din rail 1 JF 01UD

∆ Can be used with modular devices as meter pack

incoming Kits for Invicta 250 includes mounting kit, links and shroudincoming kit for 800A 3 pole MCCB 1 JF 80UC

# incoming kit order seperately

no of pack cat.

TP Ways qty. ref.with position for a 3 pole 630A (incoming# (800A MCCB kits order separately)

6 X 125A outgoing Ways 1 JF 06UM

8 X 125A outgoing Ways 1 JF 08UM

10 X 125A outgoing Ways 1 JF 10UM

12 X 125A outgoing Ways 1 JF 12UM

16 X 125A outgoing Ways 1 JF 16UM

2 X 250A + 2 X 125A outgoing Ways 1 JF 24UM

2 X 250A + 4 X 125A outgoing Ways 1 JF 26UM

2 X 250A + 6 X 125A outgoing Ways 1 JF 28UM

2 X 250A + 8 X 125A outgoing Ways 1 JF 20UM

2 X 250A + 10 X 125A outgoing Ways 1 JF 22UM

4 X 250A outgoing Ways 1 JF 41UM

4 X 250A + 2 X 125A outgoing Ways 1 JF 46UM

4 X 250A + 4 X 125A outgoing Ways 1 JF 48UM

4 X 250A + 6 X 125A outgoing Ways 1 JF 40UM

4 X 250A + 8 X 125A outgoing Ways 1 JF 42UM

6 X 250 outgoing Ways 1 JF 61UM

• delivered with protective shroud

13

enclosed fuse combination switchesand switch disconnectors

The range of enclosed FuseCombination Switches (FCS)and Switch Disconnectors (LBS)have been designed for easyinstallation. The robust enclosureis made from 1.2mm CR steeland the switching device offersthe latest technology to ensuresafe long lasting and

maintenance free operation. The switches have 4 breakpoints to ensure that a high ACrating can be obtained. The FCShas contacts either side of thefuses which ensures that thefuse connections are totally isolated when the product isswitched off. Operation of the

product is through a rotary handle that ensures that theenclosures cannot be openedwhen the device is in theswitched on position. The 3 poledevices are delivered completewith Neutral Bar & earth pointand the 4 pole with earth pointonly. The products have been

independently tested and fullycomply with the requirements ofBSEN60947-3

Knock outsand removablegland plate

Positive action door handle. Lockable off

Neutral bar

Can be top orbottom fed

Key hole mounting slots

Accepts BS88 fuses

Plastic shrouding

Robust 1.2mm steelenclosure

14

enclosed fuse combinationswitches 32-630A

designation In pack 2 pole 3 pole 4 pole

A qty. cat. ref. cat. ref cat. ref.

32A 1 JG 02FC - -

63A 1 JG 04FC - -

100A 1 JG 06FC - -

32A 1 - JG 09FC -

63A 1 - JG 11FC -

100A 1 - JG 17FC -

160A 1 - JG 23FC -

200A 1 - JG 26FC -

315A 1 - JG 30FC -

400A 1 - JG 32FC -

630A 1 - JG 36FC -

32A 1 - - JG 10FC

63A 1 - - JG 12FC

100A 1 - - JG 18FC

160A 1 - - JG 24FC

200A 1 - - JG 27FC

315A 1 - - JG 31FC

400A 1 - - JG 33FC

630A 1 - - JG 37FC

200A 1 - JG 37EF JG 38EF

315A 1 - JG 39EF JG 40EF

400A 1 - JG 41EF JG 42EF

630A 1 - JG 43EF JG 44EF

descriptionThe range of enclosed FCShave been designed to matchthe TP & N range of distribution boards. The numberof enclosure sizes have beenoptimized, to ensure that theinstallation is easy and uniform.The FCS products are designedto protect & isolate individual circuits. All handles can be padlocked in the off position.

Extension boxes are available forextra cabling space. Operation isthrough a door operated rotaryhandle.

electrical specification: Tested and complies to BSEN60947-3: LBS Sequence 1 & 3FCS Sequence 1 & 4Electrical Supply: 415V ~ AC Rating AC23A (630AAC22A)

mechanical specification:Protection Category IP 41Material 1.5mm CR4 SteelPowder Coated RAL 9001

devices & accessoriesSPSN 32 - 100A (3 ratings)TP & N 32 - 630A (8 ratings)TP & sw N 32 - 630A (8 ratings)

• for the information of dimensionsee page 22-23

JG11FC

enclosed FCS single pole switched neutral

triple pole & neutral

triple pole switched neutral

cable extension boxes

switch disconnector

15

designation In pack 3 pole 4 pole

A qty. cat. ref. cat. ref

20A 1 JG 07SC -

32A 1 JG 09SC -

63A 1 JG 11SC -

100A 1 JG 17SC -

160A 1 JG 23SC -

200A 1 JG 26SC -

250A 1 JG 28SC -

315A 1 JG 30SC -

400A 1 JG 32SC -

630A 1 JG 36SC -

20A 1 - JG08SC

32A 1 - JG10SC

63A 1 - JG12SC

100A 1 - JG18SC

160A 1 - JG24SC

200A 1 - JG27SC

250A 1 - JG29SC

315A 1 - JG31SC

400A 1 - JG33SC

630A 1 - JG37SC

250A 1 JG 37ES JG 38ES

315A 1 JG 39ES JG 40ES

400A 1 JG 41ES JG 42ES

630A 1 JG 43ES JG 44ES

triple pole & switch neutral

enclosed LBStriple pole & neutral

descriptionThe range of enclosed LBS havebeen designed to match the TP& N range of distribution boards.The number of enclosure sizeshave been optimized, to ensurethat the installation is easy anduniform. Products are designedto isolate individual circuits. Allhandles can be padlocked in theoff position. Extension boxes areavailable for extra cabling space.Operation is through a dooroperated rotary handle.

electrical specification:Tested and complies to the relevant parts of BSEN 60947-3:LBS Sequence 1 & 3Electrical Supply: 415V ~ AC Rating AC23A (630A AC22A)

mechanical specification:Protection Category IP 41Material 1.5mm CR4 SteelPowder Coated RAL 9001

devices & accessoriesTP & N 20-630A (10 ratings)TP & sw N 20-630A (10 ratings)

• for the information of dimensionsee page 22-23

JG17SC

cable extension boxes

16

IP65 switch disconnectors TP&N 20-125A

designation In cat.

A ref.

single pole & switched neutral 20A JG 220S

32A JG 232S

40A JG 240S

63A JG 263S

80A JG 280S

125A JG 225S

triple pole & neutral 20A JG 320S

32A JG 332S

40A JG 340S

63A JG 363S

80A JG 380S

125A JG 325S

descriptionThe range of IP65 switch dis-connectors are designed to beused in outdoor applications.They are rated at AC22A andoffer options of 2 pole with earthterminal or 3 pole with neutral &earth terminal. They are com-pact and easy to install. Theproduct can be locked in the offposition.

electrical specification:Tested and complies to BSEN60947-3: Electrical Supply: 240/ 415V ~ AC Rating AC22A

Mechanical Specification:Protection Category IP 65Material ABS

devices & accessories1P + N 20 - 125A (6 ratings)3P + N 20 - 125A (6 ratings)

• for the information of dimensionsee page 24

JG232S

technical information

p.18 consumer units, split bar and enclosures

p.19-20 invicta 63 - TP & N distribution boards

p.21 invicta 125, max 250A incoming, 125A outgoing

- invicta 250, max 800A incoming, 250A outgoing

p.22 enclosed fuse combination switch

- cable extension boxes ( tpn / tpsn )

p.23 enclosed load break switch

- technical information fuse combination units

p.24 IP 65 enclosed switch disconnector

18

consumer unit

consumer unit split bar

dimensions

cat. ref. H W D

HE04SN 230 210 75

HE06SN 230 246 75

HE08SN 230 282 75

HE10SN 230 322 75

HE12SN 230 354 75

HE14SN 230 394 75

HE16SN 230 426 75

HE18SN 230 466 75

• All dimensions are in mm

dimensions

cat. ref. H W D

HE42SN 230 300 75

HE52SN 230 318 75

HE62SN 230 336 75

HE53SN 230 336 75

HE63SN 230 354 75

HE73SN 230 372 75

HE84SN 230 408 75

• All dimensions are in mm

enclosures

dimensions

cat. ref. H W D

VT01E 205 142 65

VT02E 205 178 65

VT04E 205 250 65

VT06E 205 322 65

VT08E 205 394 65

VT10E 205 466 65

VT12E 205 538 65

VT14E 485 361 85

VT16E 485 397 85

• All dimensions are in mm

dimensions

cat. ref. A B C D

JD06P 485 385 125 277

JD12P 585 385 125 277

JD18P 705 385 125 277

JD24P 805 385 125 277

• All dimensions are in mm

19

invicta 63 - TP & N distribution boards

dimensions

cat. ref. no of ways A B C D

JK04PC 4 way 495 385 115 277

JK06PC 6 way 555 385 115 277

JK08PC 8 way 605 385 115 277

JK10PC 10 way 660 385 115 277

JK12PC 12 way 715 385 115 277

JK14PC 14 way 770 385 115 277

JK16PC 16 way 820 385 115 277

JK18PC 18 way 875 385 115 277

JK04FC 4 way 495 385 115 277

JK06FC 6 way 555 385 115 277

JK08FC 8 way 605 385 115 277

JK10FC 10 way 660 385 115 277

JK12FC 12 way 715 385 115 277

JK14FC 14 way 770 385 115 277

JK16FC 16 way 820 385 115 277

JK18FC 18 way 875 385 115 277

JK04GC 4 way 495 385 115 277

JK06GC 6 way 555 385 115 277

JK08GC 8 way 605 385 115 277

JK10GC 10 way 660 385 115 277

JK12GC 12 way 715 385 115 277

JK14GC 14 way 770 385 115 277

JK16GC 16 way 820 385 115 277

JK18GC 18 way 875 385 115 277

• All dimensions are in mm

20

TP & N Split bar

cat. ref. no of ways A B C D

JK22PC 2 + 2 way 595 385 125 277

JK42PC 4 + 2 way 650 385 125 277

JK62PC 6 + 2 way 705 385 125 277

JK82PC 8 + 2 way 760 385 125 277

JK92PC 10 + 2 way 815 385 125 277

JK44PC 4 + 4 way 705 385 125 277

JK64PC 6 + 4 way 760 385 125 277

JK84PC 8 + 4 way 815 385 125 277

JK94PC 10 + 4 way 870 385 125 277

JK24PC 12 + 4 way 925 385 125 277

JK66PC 6 + 6 way 815 385 125 277

JK86PC 8 + 6 way 870 385 125 277

JK96PC 10 + 6 way 925 385 125 277

JS22PC 2 + 2 way 595 385 125 277

JS42PC 4 + 2 way 650 385 125 277

JS62PC 6 + 2 way 705 385 125 277

JS82PC 8 + 2 way 760 385 125 277

JS92PC 10 + 2 way 815 385 125 277

JS44PC 4 + 4 way 705 385 125 277

JS64PC 6 + 4 way 760 385 125 277

JS84PC 8 + 4 way 815 385 125 277

JS94PC 10 + 4 way 870 385 125 277

JS24PC 12 + 4 way 925 385 125 277

JS66PC 6 + 6 way 815 385 125 277

JS86PC 8 + 6 way 870 385 125 277

JS96PC 10 + 6 way 925 385 125 277

• All dimensions are in mm

invicta 63 - TP & N distribution boards

dimensions

cat. ref. A B C

surface mounted

JN04UB /US /UM /UC 862 666 135

JN06UB /US /UM /UC 937 666 135

JN08UB /US /UM /UC 1017 666 135

JN10UB /US /UM /UC 1097 666 135

JN12UB /US /UM /UC 1172 666 135

JN16UB /US /UM /UC 1327 666 135

• All dimensions are in mm

21

invicta 125, max 400A incoming,125A outgoing

dimensions

cat. ref. A B C

surface mounted

JF06UB /UF /UM 1127 846 165

JF08UB /UF /UM 1207 846 165

JF10UB /UF /UM 1277 846 165

JF12UB /UF /UM 1357 846 165

JF16UB /UF /UM 1507 846 165

JF24UB /UF /UM 1077 846 165

JF28UB /UF /UM 1227 846 165

JF20UB /UF /UM 1307 846 165

JF22UB /UF /UM 1382 846 165

JF41UB /UF /UM 1107 846 165

JF46UB /UF /UM 1177 846 165

JF42UB /UF /UM 1407 846 165

JF61UB /UF /UM 1207 846 165

• All dimensions are in mm

invicta 250, max 800A incoming,250A outgoing

cat. ref. description height width depth

JG37EF/ JG38EF 200A 228 380 206

JG39EF/ JG40EF 315A 253 450 256

JG41EF/ JG42EF 400A 253 450 256

JG43EF/ JG44EF 630A 353 600 356

JG37ES/ JG38ES 200A 203 300 206

JG39ES/ JG40ES 315A 303 400 256

JG41ES/ JG42ES 400A 303 400 256

JG43ES/ JG44ES 630A 303 450 256

cable extension boxes (tpn/tpsn)

cat. ref. description height width depth

JG02FC 32A SPSN 353 300 135

JG04FC 63A SPSN 353 300 135

JG06FC 100A SPSN 353 300 135

JG09FC 32A TPN 353 300 135

JG10FC 32A TPSN 353 300 135

JG11FC 63A TPN 353 300 135

JG12FC 63A TPSN 353 300 135

JG17FC 100A TPN 353 300 135

JG18FC 100A TPSN 353 300 135

JG23FC 160A TPN 453 380 206

JG24FC 160A TPSN 453 380 206

JG26FC 200A TPN 453 380 206

JG30FC 315A TPN 503 450 256

JG31FC 315A TPSN 503 450 256

JG32FC 400A TPN 503 450 256

JG33FC 400A TPSN 503 450 256

JG36FC 630A TPN 703 600 356

JG37FC 630A TPSN 703 600 356

All dimensions are in mm and exclude the handle.Add 70mm to the depth to allow for the handle.

22

enclosed fuse combination switch

fused combination switch

cat. ref. description height width depth

JG07SC 20A TPN 203 150 104

JG08SC 20A TPSN 203 150 104

JG09SC 32A TPN 203 150 104

JG10SC 32A TPSN 203 150 104

JG11SC 63A TPN 203 150 104

JG12SC 63A TPSN 203 150 104

JG17SC 100A TPN 303 250 135

JG18SC 100A TPSN 303 250 135

JG23SC 160A TPN 303 250 135

JG24SC 160A TPSN 303 250 135

JG26SC 200A TPN 403 300 206

JG27SC 200A TPSN 403 300 206

JG28SC 250A TPN 403 300 206

JG29SC 250A TPSN 403 300 206

JG30SC 315A TPN 603 400 256

JG31SC 315A TPSN 603 400 256

JG32SC 400A TPN 603 400 256

JG33SC 400A TPSN 603 400 256

JG36SC 630A TPN 603 450 256

JG37SC 630A TPSN 603 450 256

• All dimensions are in mm

thermal current Ith (40oC) 32A 63A 100A 125A 60A 200A 315A 400A 630Afuse size: BS A1 A2-A3 A4 A4 B2 B2 B3 B4 C1-C2rated insulated voltage Ui (V) 690 750 750 750 750 750 1000 1000 1000impulse voltages Uimp 8000 8000 8000 8000 8000 8000 8000 8000 1200operational current Ie (A) A B A B A B A B A B A B A B A B A B400V ac AC-23A/AC-23B 32 32 63 63 100 100 125 125 160 160 200 200 315 315 400 400 630 630Motor power (kW)400V ac 9 30 51 63 80 100 160 160 220 220 355 355reactive power 400V ac (kVAR) 15 25 45 55 60 75 125 150 2x125overload capacityshort-circuit with fuses (kA Rms) 50 50 50 50 50 50 50 50 50fuse rating (A) 32 63 100 125 160 200 315 400 630BS88making & breaking characteristicsbreaking capacity 320 500 800 1000 1280 1600 2520 3200 5040400V AC-23B (A Rms)making capacity 256 630 1000 1250 1600 2000 3150 4000 6300400V AC-23B (A Rms)withstandmechanical 20000 10000 10000 10000 10000 10000 10000 10000 5000(number of operationselectrical 1500 1500 1500 1000 1000 1000 500 500 1000(number of operations)operating force (mN) 2.5 7 10 10 10 10 12 15 42connectionminimum Cu cable section (mm2) 2.5 10 25 35 50 70 185 185 2x150maximum Cu cable section (mm2) 16 25 95 95 95 95 240 240 2x300

23

technical information fusecombination units

enclosed load break switch

24

IP 65 enclosed switch disconnector

1 pole + switched neutral

ref. current H W D

JG220S 20 A 136 100 101

JG232S 32 A 136 100 101

JG240S 40 A 136 100 101

JG263S 63 A 136 100 105

JG280S 80 A 201 136 118

JG225S 125 A 201 136 118

3 pole + fixed neutral

JG320S 20 A 136 100 101

JG332S 32 A 136 100 101

JG340S 40 A 136 100 101

JG363S 63 A 136 100 105

JG380S 80 A 201 136 118

JG325S 125 A 201 136 118

• All dimensions are in mm