HA473461 Iss6 Outdoor Solar Central Inverter

Embed Size (px)

Citation preview

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    1/12

    Catalogue 2009Outdoor Central Solar Inverter890GT-S Product Brochure

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    2/12

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    3/12

    3

    Outdoor Central Solar Inverter890GT-S Series

    DescriptionThe result of over three decades of experience in power

    conversion and a commitment to sustainable energy,Parker offers unique solutions for solar power. The Out-door Solar Inverter is a megawatt class free-standingpackage designed for utility scale PV solar eld applica-tions. A high ef ciency design integrates proven IGBTpower conversion and low loss powdered metal core in-ductors with Parkers ground breaking two-phase cool-ing technology. No air conditioner is required , as thepower semiconductors, inductor, and internal ambientair are cooled by Parkers two-phase advanced coolingsystem. Integrated combiner panel and multiple accesspanels make installation and scheduled maintenance abreeze.

    FeaturesDirect outdoor installation, no shelter required

    IP65, dust-tight sealed enclosureMultiple panels for connections andcomponents provide for accessibility fromexterior of unit

    Field replaceable inverter modules

    Parker advanced 2-phase liquid cooling system

    Integral HMI touchscreen with InteractX

    Meets ARRA Made in America requirement

    Modular DesignThe Parker Outdoor Central Solar Inverter employs a uniquemodular design for ease of maintenance and service. Outputpower is handled by replaceable phase modules, which are cooledby Parkers advanced 2-phase cooling system, with no fans

    required. Each module contains IGBT power semiconductors, longlife film capacitors, and gate drive circuitry. The easily removablemodules weigh only 16 kg (about 35 pounds), and average timeto swap is under 15 minutes. Cooling and AC power connectionsare quick disconnect type, with connections made as module isinstalled. AC output filters also utilize a modular tray design foreasy maintenance. This unique modular construction offers anextremely low MTTR for high system availability.

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    4/12

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    5/12

    5

    Dimensions (mm/in)

    Outdoor Central Solar Inverter890GT-S Series

    Environmental Ratings

    Ambient Temperature Range -20 to 55 deg C, -40 deg C option available (See AC output speci cations)

    Relative Humidity 0-100% condensing

    Max. Altitude without Derating 1000 metersCorrosion resistance >600 hours salt fog per ASTM B117-11 (option)

    Mechanical Data

    Environmental Protection Rating IP65, EN60529

    Size (W x D x H) mm (in) 3272 (128.8) x 1679 (66) x 2646 (104.2) See detail below

    Weight (approximate) 4000 kg/8820 lb

    Cooling System 2-phase Parker advanced cooling

    Compliance to Standards

    European Certi cations CE: LVD,EMC, G5/4 & G59/1 (pending)

    North American Certi cations UL1741 pending

    Harmonics IEEE 519, IEEE 1547

    EMC EN61000-6-2, EN 61000-6-4

    Forklift tubes

    Forklift tubes

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    6/12

    6

    Outdoor Central Solar Inverter890GT-S Series

    Smart OperationThe Parker 890GT-S includes features that make it friendly to the grid. Inverter trips and disconnections areminimized in the rmware, ensuring that the inverter remains a valuable asset to the user, and not a liability tothe health of the grid during disturbances.

    - Communications capabilities allow fast and accurate monitoring and control of all inverter functions.

    - Real and reactive power support enables the inverter to help mitigate voltage excursions, taking the burdenoff the electric utilitys traditional voltage and frequency regulating equipment.

    - Dynamic VAR injection provides reactive power (Q, measured in VARs) when called upon. In addition to itsprimary purpose of feeding active power (P, measured in watts) from the solar panels to the grid, the 890GT-S

    can, within the obvious limitations of rated current and power factor, produce a reactive power component ondemand.

    - Expanded frequency trip point allows continued operation without disconnection during many grid frequencyexcursions.

    - Low-voltage ride through capability (LVRT) ensures that the 890GT-S will not trip during transientdisturbances, thus avoiding making the situation worse by dropping of ine.

    Visualization/HMIStandard 890GT-S Central Solar Inverters include a Parker 10 industrial hardened workstation as a supervisoryHMI. The workstation includes an SVGA display with analog resistive touchscreen, and has a built-in solid statehard drive for fast and reliable data storage. The pre-programmed operating and monitoring screen run on ParkerInteractX software for advanced graphics, historical trending, and sophisticated communication capabilities.

    Control and DiagnosticsThe HMI is accessible from outside the enclosure, covered by a protective door. The HMI provides a wealth ofuseful operating data on a real-time basis. Data is presented on a number of concise screens using an easy-to-navigate menu structure. An Electrical Overview screen includes operating mode, inverter output kW orVARs, critical voltages and currents, and solar panel performance data. The Thermal Overview screen takesfull advantage of over 60 internal temperature monitoring points, giving the operator an overall view of thermalstatus. Coolant flow, level, and temperature are closely monitored, as is the speed and status of the fans.

    Additionally, screens dedicated to alarms and data trending provide for efficient diagnosis and status reports.By virtue of the InteractX software, display screens can be customized for your system, allowing visualizationof virtually any operating parameter. Also provided, accessible by an exterior panel, are hardware switchesfor inverter on/off, local/remote, lighting, and control power, an Emergency Power Off button, and a localcommunication port.

    Features

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    7/12

    7

    Outdoor Central Solar Inverter890GT-S Series

    Field Diagnostics PV Cell current (by string) Ground current

    Basic Parameters Grid voltage and current DC bus voltage and current Power factor Performance Target and actual kilowatt output Target and actual kVAR output Target and actual power factor Power output ramp rates

    Efficiency Cumulative energy output

    Climate Control Diagnostics Coolant levels Fan speeds Pump and fan status Over 60 internal temperature points Coolant temperature IGBT temperature Contactor temperatures Choke temperatures Busbar temperatures Air temperature and humidity

    Digital chart recorder Customizable SCADA interface SQL database with solid state drive Displays and records any parameter Displays real time or log

    SecurityThe HMI may be set up for an administrator and multiple users, with up to five levels of passcode protectedaccess. Operators, supervisors, and technicians can be provided with access to only the levels that they havethe need to work with, without exposing sensitive or critical parameters. InteractX simplifies record keepingcompliance by tracking operator input and providing electronic signatures that are easily configured withno special scripting or programming required. The inverter system uses a non-routable private IP, allowingintegration with your established firewall. If you are interested in remote access, Parker can recommend aprogram that includes full encryption, based on RSA private-/public key exchange and AES (256 Bit) sessionencoding. This technology is based on the same standards as https/SSL. On the hardware level, a heavy gaugesteel enclosure with lockable access panels prevents unauthorized tampering or access.

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    8/12

    8

    Outdoor Central Solar Inverter890GT-S Series

    Operating ModesBasic operating modes include Grid Parallel (current mode) and Island (voltage mode) Slew rate control for both realand reactive power make the AC890GT-S grid friendly, and MPPT control ensures the maximum energy harvest, evenduring non-optimum days.

    ProtectionThe Parker Outdoor Central Solar Inverter is equipped with a comprehensive list of protective devices for safe andreliable operation.DC Inputs: Fuse, current sensor on each leg. Contactor disconnect and ground fault current sensor.DC Bus: Fuse protection.

    AC Output: Circuit breaker, phase current sensors (2).

    Energy Management ModesThe 890GT-S includes sophisticated energy managementcapabilities that allow the user to reap maximum energyoutput, maintaining performance during grid frequency orvoltage excursions, while maintaining compliance with most oftodays codes and standards.

    Voltage Ride-through/Droop Response - In additionto basic low voltage ride-through (LVRT), the 890GTautomatically injects available reactive current if line voltagedroop is sensed.

    FqRT/Frequency Ridethrough - Output current is limitedfor increasing frequency.

    VAR or Power Factor Control - Command the powerfactor required.

    Battery Energy Storage IntegrationEnergy storage is recognized as an enabler for the addition of renewable power sources. By combining storage withgeneration, a complete grid interactive system is created. Ramp control algorithm for both active power and VARsmakes the Parker 890GT-S Solar Inverter easily adaptable to energy storage. With common communication platformand protocols, the inverter may be seamlessly integrated with Parkers 890GT series energy storage PCS. With over 85Megawatts installed, Parker has a proven track record in energy storage. Systems are not limited to a particular batterychemistry, and are modular in construction for easy transport and deployment.

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    9/12

    9

    Outdoor Central Solar Inverter890GT-S Series

    Parker Advanced Cooling SystemThe small footprint and high reliability of the Parker Outdoor CentralSolar Inverter is made possible by an advanced cooling system.

    Parkers exclusive coolant-based system uses a non-conductive, non-corrosive liquid to cool critical components. The refrigerant used in thistwo phase system requires only 13% of the flow rate of an equivalentwater/glycol based system. By capitalizing on the tremendous amountof heat that is transferred as the refrigerant vaporizes, then releasingthe heat through a condenser, the cooling system runs efficiently andeffectively, without the need for a compressor. Redundant systemcomponents will allow inverter operation even after loss of a pumpor a fan. (Output may be reduced under certain operating conditions)Compared to air cooling, IGBT temperatures are kept more constant,with less excursions over time.

    Advanced cooling is used on both the IGBT devices and the highefficiency inductors, as well as with the unique cool door feature,circulating temperature controlled air inside the sealed enclosure.Heat from the coolant loop is removed by an isolated heat exchanger,with no air exchange from the enclosure interior to the outsideenvironment. Heat exchanger fans are variable speed for maximumefficiency. They are designed for redundancy, and are monitored forrotation. In the event of a fan or coolant pump malfunction, the inverterwill continue to operate, folding back power if necessary. The coolingsystem is designed for a minimum of maintenance, and there are noair filters to change.

    IGBTs mounted on cold plate (Cover removed for clarity) Quick-break no-leak coolant connectors

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    10/12

    10

    Transformer Coupling ProvisionThe 890GT-S is designed to be easily pad mounted/skid mounted with a transformer, and includes a connection chuteto protect the three phase output lugs.

    Outdoor Central Solar Inverter890GT-S Series

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    11/12

    11

    Outdoor Central Solar Inverter890GT Series

  • 8/12/2019 HA473461 Iss6 Outdoor Solar Central Inverter

    12/12

    2013 Parker Hannin Corporation. All rights reserved. Parker Hannifn CorporationEnergy Grid Tie Division9225 Forsyth Park Dr.Charlotte, NC 28273 USA Tel: (704) 588-3246 Fax: (704) [email protected]/gridtie

    HA473461 Iss6, Nov 2013

    AE UAE, DubaiTel: +971 4 [email protected]

    AR Argent ina, Buenos AiresTel: +54 3327 44 4129

    AT Austria, Wiener NeustadtTel: +43 (0)2622 23501-0

    [email protected] AT Eastern Europe,Wiener NeustadtTel: +43 (0)2622 23501 [email protected]

    AU Australia, Castle HillTel: +61 (0)2-9634 7777

    AZ Azerbaijan, BakuTel: +994 50 2233 [email protected]

    BE/LU Belgium, NivellesTel: +32 (0)67 280 [email protected]

    BR Brazil, Cachoeirinha RSTel: +55 51 3470 9144

    BY Belarus, MinskTel: +375 17 209 [email protected]

    CA Canada, Milton, OntarioTel: +1 905 693 3000

    CH Switzerland, EtoyTel: +41 (0)21 821 87 [email protected]

    CL Chile, Santiago Tel: +56 2 623 1216

    CN China, ShanghaiTel: +86 21 2899 5000

    CZ Czech Republic, KlecanyTel: +420 284 083 [email protected]

    DE Germany, KaarstTel: +49 (0)2131 4016 [email protected]

    DK Denmark, BallerupTel: +45 43 56 04 [email protected]

    ES Spain, MadridTel: +34 902 330 [email protected]

    FI Finland, VantaaTel: +358 (0)20 753 [email protected]

    FR France, Contamine s/ArveTel: +33 (0)4 50 25 80 [email protected]

    GR Greece, AthensTel: +30 210 933 [email protected]

    HK Hong Kong

    Tel: +852 2428 8008HU Hungary, BudapestTel: +36 1 220 [email protected]

    IE Ireland, DublinTel: +353 (0)1 466 [email protected]

    IN India, MumbaiTel: +91 22 6513 7081-85

    IT Italy, Corsico (MI)Tel: +39 02 45 19 [email protected]

    JP Japan, TokyoTel: +81 (0)3 6408 3901

    KR South Korea, SeoulTel: +82 2 559 0400

    KZ Kazakhstan, AlmatyTel: +7 7272 505 [email protected]

    LV Latvia, RigaTel: +371 6 745 [email protected]

    MX Mexico, ApodacaTel: +52 81 8156 6000

    MY Malaysia, Shah AlamTel: +60 3 7849 0800NL The Netherlands,OldenzaalTel: +31 (0)541 585 [email protected]

    NO Norway, SkiTel: +47 64 91 10 [email protected]

    NZ New Zealand, Mt WellingtonTel: +64 9 574 1744

    PL Poland, WarsawTel: +48 (0)22 573 24 [email protected]

    PT Portugal, Leca da PalmeiraTel: +351 22 999 [email protected]

    Parker WorldwideRO Romania, BucharestTel: +40 21 252 [email protected]

    RU Russia, MoscowTel: +7 495 [email protected]

    SE Sweden, SpngaTel: +46 (0)8 59 79 50 [email protected]

    SG SingaporeTel: +65 6887 6300

    SK Slovakia, Bansk Bystrica Tel: +421 484 162 [email protected]

    SL Slovenia, Novo MestoTel: +386 7 337 [email protected]

    TH Thailand, BangkokTel: +662 717 8140

    TR Turkey, IstanbulTel: +90 216 [email protected]

    TW Taiwan, TaipeiTel: +886 2 2298 8987

    UA Ukraine, KievTel +380 44 494 [email protected]

    UK United Kingdom,WarwickTel: +44 (0)1926 317 [email protected]

    US USA, ClevelandTel: +1 216 896 3000

    VE Venezuela, CaracasTel: +58 212 238 5422