H56857 IH Cap Brochure 0807web

Embed Size (px)

Citation preview

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    1/20

    I n d u s t r i a l

    H e a t T r a c i n g

    Products and Services

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    2/20

    Heat Tracing Temperature Measurement

    Services

    Wiring Products

    Floor Warming Specialty Heaters

    Leak Detection

    A Solutions CompanyTyco Thermal Controls is the world leader in heat-tracing products and solutions for the industrial,commercial and residential markets. Employing over2,000 people globally, Tyco Thermal Controls has theexperience and product breadth to meet your heat-tracing requirements.

    Worldwide ApproachWith operations in 48 countries and worldwideexperience, Tyco Thermal Controls supports yourproject efforts anywhere, anytime. Whether its top-notch products or turnkey services, Tyco ThermalControls has the solution.

    The Market DemandsWe SupplyFrom Heat-Tracing Systems, Specialty Heaters andFloor Warming to Wiring, Temperature Measurement,and Leak Detection, we are able to offer innovativesolutions worldwide. Furthermore, we proudly provideTurnkey Services for eachWORLDWIDE!

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    3/20

    We manage the heat you need

    1

    For every heat-tracing need, depend on the undisputed industry leader.

    Tyco Thermal Controlsstands as the world leader in heat-tracingsolutions for the industrial, commercial, and residential markets. Aninnovative company, Tyco Thermal Controls offers top-notch productsand turnkey services under such industry renowned names asRaychem,Tracer,Pyrotenax,and DigiTrace.

    We offer the most complete line of heat-tracing systems and havemanufactured over one billion feet of heating cable. As the inventorof self-regulating heat tracing, our Raychembrand is known fortechnical expertise in polymer science and radiation cross-linkingboth critical parts of the process. Also an industry leader in themanufacture of mineral insulated cables, Tyco Thermal Controls is wellknown for its Pyrotenaxbrand.

    Tyco Thermal Controls DigiTracebrand offers the most complete line ofheat-trace control and monitoring systems-from single circuit mechanicalthermostats to multi-circuit, microprocessor-based networked systems.Our DigiTraceSupervisor software links your control and monitoringsystem back to a PC for centralized control system monitoring.

    Our Services Division, is widely regarded as the premiere providerof turnkey heat-tracing solutions in the industrial market today.Offering turnkey engineering, design, construction and maintenance,Tyco Thermal Controls is capable of handling heat-tracing projectsof any size and scope. By focusing on safety and utilizing the value-added capabilities made available by Raychem, Pyrotenax, Tracer,and

    DigiTraceproducts, Tyco Thermal Controlsheat-tracing installationsare timely, thorough, and cost-effective.

    With operations in 48 countries and worldwide experience, Tyco ThermalControlscan support your project efforts anywhere in the world.

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    4/202

    Heat-Trace Panel(may include circuitbreakers, controllers

    and alarms)

    Transformer

    Lighted End Seal

    Cable Tray

    Note: The illustrations onthese pages do not necessar-ily depict actual applicationsand installations.

    A typical crosssection of an electricallyheat-traced pipe.

    Electric Heat-Traced Pipe

    Fluid

    Heatingcable

    Insulation

    Cladding

    Power Connection

    Heating Cable

    Field MountedThermostat or Controller

    (when required)

    Electric Heat-Tracing Systems

    A complete electrical heat-tracing system is muchmore than just the heating cable. Tyco ThermalControls can provide a complete system fromelectrical transformer and heat-trace panel to powerconnections, heating cable, end terminations, glasstape and warning labels. We can supply the individualcomponents, provide engineering and design andeven install and maintain the entire system.

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    5/203

    A typical cross section of asteam-traced pipe.

    Steam-Traced Pipe

    Fluid

    Copper orstainlesssteel tubing

    Insulation

    Cladding

    Steam Supply

    Steam SupplyManifold

    Steam-Tracing

    CondensateReturnManifold

    CondensateReturn

    A steam-tracing system may be chosen for a particularsite or process consideration. A complete systemcan consist of a steam supply source, steam tubing,valves, traps, and return lines. Tyco Thermal Controlscan supply a complete steam-tracing system fromengineering, design, material supply and installation.

    Steam-Tracing Systems

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    6/20

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    7/205

    Safety

    Safety is our number one concern. We are recognized as aleader in the industry in safety performance by consistentlychallenging the norm through safety innovations includingtraining and motivational programs. Committed to safety

    through proactive safetymanagement techniques.

    Warm Pipe Warranty

    By allowing Tyco Thermal Controls to handle all of the engineering, design, andconstruction of your heat-tracing system, we can provide you with a Warm PipeWarranty, ensuring that the system operates as specified.

    WARM PIPE

    W

    ARR ANT

    Y

    Procurement & Fabrication

    Tyco Thermal Controls manufactures a wide range of heat-tracing products andcomponents for the most demanding heat-tracing applications. We can order, ship andreceive materials for you. Heat Management System components include:

    Heat Delivery System which is either electrically powered or transfers heat throughre-circulating fluids such as glycol, steam or hot oil.

    Control & Monitoring Systemof the heat delivery system.

    Utility Distribution System which can be electricity, steam/condensate, hot oil, orglycol to the heat delivery system.

    Thermal Insulation Systeminstalled over the heat delivery system.

    Instrument Winterizationin the form of pre-packaged instrument enclosures andpre-traced/pre-insulated tube bundles.

    Comprehensive designcapabilities include allaspects of electric andcirculating fluid tracingsystems

    Site Services

    Using Tyco Thermal Controls Site Services allows you to maintain a single point ofresponsibility and accountability through the entire Heat Management System process,and you ensure continuity of project knowledge from engineering through start-up.We can manage all the necessary services you need: Engineering, Procurement,Construction, Construction Management, Quality Assurance, or any variation thereof.

    Post-Installation Services

    Initiating a Heat Management System audit,or implementing a maintenance agreement,provides you with the security of having

    your system regularly evaluated by expertsin the heat-tracing industry, allowing timelyresolution of potential system problems.

    Quality Assurance & Quality Control (QA / QC)

    Tyco Thermal Controls Quality Management System addresses all processes includingthe design, supply, installation, and commissioning to ensure your Heat TracingSystem is operating as intended when commissioned.

    We manage the heat

    you needTM

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    8/20

    SELF-REGULATING CABLES

    The preferred choice for most complex pipe-tracing applications.

    Heat-Tracing Products

    6

    Our industrial heating cables are backed by

    a ten-year extended warranty!

    Raychem XTVfiber-wrap cableprovides process temperaturemaintenance up to 250F (121C)and withstands intermittent

    exposures to 420F (215C).

    Raychem QTVRcable providesfreeze protection and process tem-perature maintenance, maintainingand withstanding exposure

    temperatures up to 225F (110C).

    Raychem BTVcable provides freezeprotection on metal and plasticpipes, maintaining temperaturesup to 150F (65C) and withstand-

    ing exposure to 185F (85C).

    Tyco Thermal Controls offers the industrys most complete line of heat-tracing products to meet every needfor everything from pipe freezeprotection to high temperature process maintenance.

    POWER-LIMITING CABLES

    For applications exceedingthe temperature range of self-regulating cables.

    Raychem VPLheating cable main-tains temperatures greater than300F (150C) and withstandscontinuous exposure to 500F(260C), power off.

    Note: These photos and illustrationsdo not necessarily depict actual applicationsand installations.

    MINERAL INSULATED CABLES

    For high temperature applications.

    Pyrotenax MIcable maintainstemperatures up to 1022F (550C)and withstands continuous exposureto 1200F (650C).

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    9/207

    ADVANCED HEAT-TRACING COMPONENTS

    Raychempower connections, tees, and splices are vital parts ofany heat-tracing system. These high-quality advanced componentsare easy to install and will deliver reliable service. All install withouta torch, heat gun, or messy sealants!

    Spring clamp terminals provide reliable connection and allow easyreentry.

    The power connection installs in less than 10 minutes, usingonly standard cable-stripping tools and a screwdriver.

    High-intensity LED lights are available with our power con-nections and end seals to provide visual monitoring of systempower and continuity.

    LONGLINE HEATING

    Choose from the most completeselection of longline heat-tracingsystems and technologies.Circuit lengths can vary from500 feet (152.4 meters) to over15 miles (24 kilometers):

    RaychemSelf-regulating systems,LBTV, SLBTVand VL cables

    RaychemSeries resistance

    systems, SC cables Pyrotenax MImineral insulated

    cables

    Tracer STSskin-effect system

    SNOW AND ICE PREVENTION

    Raychemself-regulating heating cables areinstalled in concrete to prevent dangerousicing on loading ramps, walkways, entrances,and driveways.

    Raychemheating cables are installed on roofsand gutters to prevent hazards and propertydamage caused by ice buildup.

    Both systems automatically adjust their heatoutput in response to ambient temperatures, forbetter reliability and energy efficiency.

    Pyrotenaxmineral insulated cables areinstalled in concrete and asphalt and provide aconstant heat output.

    TANK HEATING

    Choose from tank pad heaters andheating cables for tank and vesselheating solutions.

    The Raychem RHStank heatingsystem maintains tank tempera-tures up to 200 F (93C). Heatersare available from 150 watts to1,400 watts.

    RHS-Lheaters can be used

    on polypropylene, FRP, and metaltanks.

    TUBING BUNDLES

    Raychemtubing bundles (RTB)offer a cost-effective alternative totraditional field tracing and insulating.

    Pre-traced and pre-insulated tubing

    bundles for such applicationsas impulse, sample, and processlines

    Choice of single or dual tubing

    in stainless steel, monel, copper,

    PFA Teflon, or other materials Choice of electric or steam-traced

    bundles

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    10/20

    Cold Pipe:In response

    to cold, the core or

    fiber contracts micro-

    scopically opening up

    electrical paths.

    Copper

    bus wire

    BTV and QTVR

    heating cables

    share a similar

    construction as

    illustrated at right.

    XTV heating

    cables feature

    a fiber-wrapconstruction

    that can easily

    be cut back

    for power

    connection and

    termination.

    Self-

    regulating

    conductive-

    core heating

    element

    Insulating

    jacket

    Braided

    tin-copper

    shield and

    outer jacket

    Copper

    bus wire

    Self-

    regulating

    conductive

    fiber

    Insulating

    jacket

    Braided

    tin-copper

    shield and

    outer jacket

    Warm Pipe:In response

    to warmth, the core or

    fiber begins to expand

    microscopically disrupt-

    ing the electrical paths.

    Hot Pipe: The core or

    fiber expands enough

    to disrupt almost all

    of the electrical paths.

    How self-regulation works in the Raychem conductive-polymer heaters:

    Temperature

    Resistance

    Temperature

    Power

    Constant WattageConstant Wattage

    8

    Innovative Heat-Tracing Technologies

    Tyco Thermal Controls self-regulating and power-limiting systemsconsist of insulated electric heating cables with voltage appliedto two parallel bus wires. This enables the cables to be cut toany length, then spliced and teed in the field.

    SELF-REGULATING TECHNOLOGY

    This technology was used in designing the two types of self-regulating, polymeric heating elements illustrated at right.In both the monolithic (solid core) and fiber wrap products, theheating element is made of polymer mixed with conductivecarbon. This special formulation of materials creates an electrical

    path for conducting current between the parallel bus wires alongthe entire cable length.

    In each heating cable, the number of electrical paths betweenthe bus wires changes in response to temperature fluctuations.As the temperature surrounding the heater decreases, theconductive core or fiber contracts microscopically. This contractiondecreases electrical resistance and creates numerous electricalpaths between the bus wires. Current flows across these pathsto warm the core or fiber.

    As the temperature rises, the core or fiber expands microscopically.This expansion increases electrical resistance and the numberof electrical paths decreases. The heater automatically begins to

    reduce its power output.

    The graphs above illustrate the response of self-regulatingheating cables to changes in temperature. As thetemperature rises, electrical resistance increases, and ourheaters reduce their power output.

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    11/20

    Temperature

    PowerOutput

    Rapid Startup

    Energy Savings

    $

    RaychemSelf-Regulating

    Systems

    ConventionalHeatingCables

    Fluoropolymer outer jacket

    Fluoropolymer inner jacket

    Bus wire connection

    Clear jacket

    Nickel-plated bus wires

    Metal braidPower-limitingheating element

    Fiberglass yarn

    PTC alloy

    Exposure Temperature

    MaintenanceTemperature

    Asphalt

    Sulfur

    Fuel Oil

    Caustic Soda

    Water

    Mineral Insulated - MI

    Power Limiting - VPL

    Self RegulatingFiber - XTV

    Self RegulatingMonolithicBTV, QTVR

    Water TreatmentFood

    Primary Metals

    RefiningPulp and Paper

    Chemicals

    Utilities

    9

    Tyco Thermal Controls self-regulating systems offer:

    Easy installation Parallel circuitry and flat cable design makes Raychemheat-tracing systems easy to handle and install. They may be cutto length on site, and overlapped at valves, flanges, and instruments.

    Rapid start-up Provides high power output as needed. This means fast start-upand less downtimewhen pipes or other application surfaces are cold.

    Reduced operating costs The system compensates for variablessuch as heat sinks, as well as fluctuations in voltage and temperature.Heat is automatically supplied only when and where needed.

    Uniform temperatures Because the heater senses and responds toactual conditions along the pipe, the system automatically accommodatesvariations due to static fluid and differing elevations.

    Unconditional T-ratings Our self-regulating heating cables offer uncondi-tional T-ratings, as specified by the National Electrical Code, article 500-8 (B).

    POWER-LIMITING TECHNOLOGY

    The power-limiting VPL heater is based on a coiled resistor alloy-heating element wrapped around two parallel bus wires. The

    resistance of this heating element increases as its temperatureincreases, creating a positive temperature coefficient (PTC) effect.

    The PTC effect results in a decrease in power output at elevatedtemperatures. This allows the VPL to cross over itself without damagefrom overheating.

    Choose the right technology for your heat-tracing application.Tyco Thermal Controls offers the greatest selection in self-regulating, power-limiting and mineral insulated heating cables.

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    12/2010

    Multipoint Control and Monitoring Systems

    DigiTrace multipoint control and monitoring systems provide scalablesolutions for both hazardous and nonhazardous locations. The systems sense

    pipe or tank temperatures to provide tight control in process temperaturemaintenance or critical freeze protection applications. They also featurecontinuous monitoring technology to detect heat-tracing faults, monitor heat-tracing current and provide networking capabilities.

    DigiTrace NGC-30 This microprocessor-based controller represents TycoThermal Controls next generation controllers. The User Interface Terminal(UIT) utilizes touch screen technology to simplify programming, monitoringand fault identification. The NGC-30 systems with the UIT are approved foruse in both hazardous and nonhazardous locations. This system can supportup to 260 heat-tracing circuits and is compatible with the RMM2 temperaturemonitoring module. Each heat-tracing circuit can be independentlyprogrammed to provide maximum system flexibility.

    Features: Control and monitoring with high/low current and temperature alarms

    Meets NEC requirements for ground-fault trip protection Up to 60-Amp solid-state relays or mechanical contactors

    Communication with host system over Ethernet or an RS-485 twisted pair RTD failure alarm

    Can be located in Hazardous Class I Div 2 hazardous locations

    DigiTrace T2000 This microprocessor-based controller uses a single con-trol card per heat-tracing cable architecture to maximize system reliability.The singlepoint T2000 control modules are easily inserted into a rackassembly as circuits are added. Individual circuits may be locked out or

    changed without affecting other circuits. Optional hand-held programmeravailable for both hazardous and nonhazardous locations allows for localdigital communications.

    Single- and Dual-Point Control and Monitoring Systems

    DigiTrace 910 and 920 Both the 910 (single-point controller) and the 920(dual-point controller) provide the same features as the T2000 multi-circuitcontrollers. These controllers are designed for use when just a few linesof heat-tracing are required. Both controllers are available for hazardousand nonhazardous locations, and are fully compatible with the DigiTraceSupervisor software.

    DigiTrace JBS-100-ECP-A and JBS-100-ECW-A These electronic temperaturecontrollers provide accurate control of a single heating circuit using a RTD sen-sor. The JBS-100-ECP-A is pipe-mounted and serves as a power connectionkit for both Raychem self-regulating and Pyrotenax mineral insulated heatingcables. The JBS-100-ECW-A is wall-mounted, and may be used with all types ofheating cables. Both the JBS-100-ECP-A and JBS-100-ECW-A have adjustableset points between 32F to 425F (0C to 218C), power input of 120 Vac to277 Vac and switches current up to 30 A.A local display allows for monitoring of set point, actual temperature and alsoindicates alarm conditions. These units are c-CSA-us (certified to U.S. andCanadian Standards) for use in nonhazardous locations.

    Advanced Heat-Tracing Control and Monitoring Systems

    Portableprogrammer

    920 series

    910 series

    JBS-100-ECW-AJBS-100-ECP-A

    CM2000+ T2000

    NGC-30RemoteMount UIT

    CRM/CRMS

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    13/2011

    Additional Heat-Tracing Controls and Heat-Trace Panels

    Heat-Trace Panels

    DigiTracededicated power-distribution panels canreduce costly field wiring and reduce controller costs.Choose from a complete line of dedicated heat-tracing

    power distribution panels. Each is available with:

    Group or individual circuit control

    Standard circuit breakers, ground-fault breakers, or

    ground-fault breakers with alarm

    Supervisor Software

    The DigiTraceSupervisor software enablesusers to interface with field installed DigiTrace

    NGC-30, 910, 920 and T2000 control Systems.The Windows-based Supervisor software canbe used to program individual units or groupsof units, monitor, check, and record alarm status,data log, and generate reports.

    Thermostats and RTDs

    DigiTracesimple ambient and linesensing mechanical or electronic thermostats are for

    use in nonhazardous and hazardous locations.

    Also choose RTDs for nonhazardous and hazardouslocations as well as low and high temperatureapplications.

    Remote Temperature Monitoring

    DigiTraceControl and Monitoring Systems

    are supported by remote temperaturemonitoring devices. These devices aredesigned to help reduce costs by eliminatinghome runs for RTDs. The devices areavailable for hazardous and nonhazardouslocations.

    RMM2 SES

    E507S-LS RTD4AL

    HTPIHTPG

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    14/2012

    Engineered Products

    Steam-Tracing Systems

    Providing complete steam-tracing and recirculating fluid-tracing systems, Tyco Thermal Controls Servicesinclude notonly installation, but also isometric detail drawings with heat-tracing parameters and calculations, typical and project specificinstallation details, nameplate and tagging schedules, completesystem Bill of Material generation, and post-construction as-builtdocumentation. These, along with established project managementtechniques, ensure your steam-heating system performs asrequired.

    Pipe Shoes

    The Interlockclamp-on pipe shoe is a patented pipe support designthat eliminates field welding requirements for pipe supports,which is a significant benefit in heat-tracing design and construction.It can be used on all pipe applications, including bare pipe, paintedpipe, insulated pipe, and heat-traced pipe.

    Pre-traced Pre-Insulated Safety Stations

    ShowerGuardpre-traced, pre-insulated safety shower/eyewash unitis designed to minimize field installation requirements and eliminatethe numerous disadvantages associated with field installations ofelectric heat-trace cable, insulation, and moisture-barrier jacketing.

    Tyco Thermal Controls offers a wide array of engineered productsfor the industrial market. Each product is designed to add value toeven the simplest of heat-tracing installations.

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    15/2013

    Pre-Fabricated EHT Buildings

    Systems containing a large number of heat-tracing circuitscontained within a small amount of real estate may benefit fromthe use of a Pre-Fabricated EHT building. These buildingsprovide a common location for heat-trace controllers and powerdistribution. They may also include dedicated heat-trace trans-formers and dedicated control and monitoring software, as wellas provide a well-organized, comfortable area in which to serviceyour heat-tracing system. Additional benefits include reducedpower distribution and control wiring as well as greatly reducedfield construction cost and scheduling concerns.

    Tank Insulation Systems

    Trac-Locstanding lock seam insulation system deliversstructurally superior, maintenance-free, and lower-cost insulationthan conventional tank insulation methods.

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    16/2014

    Web Services and Software

    Visit www.tycothermal.com

    All the tools and information you need todesign, select, and purchase a complete heat-tracing system. Use our Web-based program,or download design software to use off-line. Download, print, or browse product datasheets and installation instructions.

    Design On-LineTraceCalc Net is an on-line tool that walks you through heat tracedesign in three simple steps: Finding the right products for your application

    Choosing quantities for a complete bill of materials Selecting optional control and monitoring systems

    On-Line Technical Support

    On our interactive frequently asked questions and answers (FAQ)page, youll find questions broken down by markets and product lines.

    If your question does not appear, simply submit a new question.A Tyco Thermal Controls technical expert will answer your question andpost it to the Web site.

    Download Design SoftwareSave time with TraceCalc

    Pro.

    This software provides completeheat-tracing designs forpipes, tanks and vesselsin a fraction of the timeneeded for manual design.

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    17/2015

    We manage the heat you needTM

    Before you buy, weigh the facts:

    The leading full-service integrator Nobody puts theentire system together better. By optimizing Heat-Tracing,Insulation and Power Distribution requirements with anunbiased selection of technologies, our turnkey serviceswill bring your project predictable, reliable results.

    Greater selection Offering the most complete productline of proven heat-tracing technologies to better satisfyyour unique needs.

    More innovation As a world leader in heating cabletechnologies, heat-tracing design optimization, construction,and control and monitoring systems we invented many oftodays industry standards.

    More manufacturing experience Quality-driven manu-facturing processes, combined with years of manufacturingself-regulating and mineral-insulated cables gives youproducts proven to be the most reliable.

    The most advanced line of control and monitoring systemsFrom single circuit mechanical thermostats to multi-circuit,

    microprocessor-based networked systems, we can meetall of your control and monitoring requirements, allowingyour system to run safely, reliably and profitably.

    For Proven Heat-Tracing Solutions, Look to the Leader.

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    18/20

    Menlo Park, CAWorld Wide Headquarters

    Trenton, Ontario

    Baton Rouge, LA

    Service Centers

    Manufacturing Centers

    Houston, TX

    Edmonton, Alberta

    Philadelphia, PAChicago, IL

    SALES OR TECHNICAL SUPPORT

    Visit our website at www.tycothermal.com

    or contact us at 1-800-545-6258.

    NORTH AMERICAN OPERATIONS

    16

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    19/20

    Worldwide HeadquartersTyco Thermal Controls2415 Bay RoadRedwood City, CA 94063-3032USATel: (800) 545-6258Tel: (650) 216-1526Fax: (800) 527-5703Fax: (650) [email protected]

    Service Headquarters

    Tyco Thermal Controls7433 Harwin DriveHouston, TX 77036USATel: (800) 545-6258Fax: (800) 527-5703

    U.S.A.

    Tyco Thermal Controls2415 Bay RoadRedwood City, CA 94063-3032USATel: (800) 545-6258Fax: (800) 527-5703

    CanadaTyco Thermal Controls250 West St.Trenton, OntarioCanada K8V 5S2Tel: (800) 545-6258

    Fax: (800) 527-5703

    Latin AmericaTyco Thermal ControlsCarlos Calvo 2560 (C1230AAP)Buenos Aires, ArgentinaTel: (54 11) 4 308 6444Fax: (54 11) 4 308 6445

    Europe

    Tyco Thermal ControlsStaatsbaan 4A3210 LubbeekBelgiumTel: (32) 16/213-511Fax: (32) 16/213-600

    South East Asia/Middle EastTyco Thermal Controls1st Floor, Ujagar Compound,Sub Plot 2A, CTS No. 653/6,Opp. Deonar Bus Depot,Deonar, Mumbai

    400 088 IndiaTel: 91-22-2550 9890/91/92/...98Fax: 91-22-2556 1491

    AsiaTyco Thermal Controls20F, Innovation Building,1009 Yi Shan Rd,Shanghai 200233,P.R.ChinaTel: 86-21-2412-1688Fax: 86-21-5426-2937 / 5426-3167

  • 8/13/2019 H56857 IH Cap Brochure 0807web

    20/20

    2007 Tyco Thermal Controls LLC H56857 08/07

    Important:All information, including illustrations, is believed to be reliable.Users, however, should independently evaluate the suitability of each prod-uct for their particular application. Tyco Thermal Controls makes no warran-ties as to the accuracy or completeness of the information, and disclaims

    any liability regarding its use. Tyco Thermal Controls only obligations arethose in the Tyco Thermal Controls Standard Terms and Conditions of Salefor this product, and in no case will Tyco Thermal Controls or its distributorsbe liable for any incidental, indirect, or consequential damages arising fromthe sale, resale, use, or misuse of the product. Specifications are subject tochange without notice. In addition, Tyco Thermal Controls reserves the rightto make changeswithout notification to Buyerto processing or materialsthat do not affect compliance with any applicable specification.

    Tyco, 5GF-C, 200NI, 200NG, 910, 920, Automatrix, AMC-1A, AMC-1B, AMC-1H, AMC-

    2B-2, AMC-F5, BTV, Chemelex, CM2000+, DigiTrace, E-100, E-100-L, E-150, ElectroMelt,

    E104, E304, E307, E507-LS, E507-2LS-2, HAK-C-100, HBTV, HQTV, HTPG, HTPI, HXTV,

    IceStop, Isopad, JBM-100, JBS-100, KTV, LBTV, MoniTrace, NGC-30, PLI, Pyrotenax, QTVR,

    RAYSTAT-EX-03-A, RHS, RHS-L, RMM2, RTB, RTD 10/20, RTD-200, RTD-300-10, RTD3CS,

    RTD4AL, RTD7AL, RTD10CS, S-150, SC, SES, ShowerGuard, SLBTV, T-100, T2, T2000,

    Trac-Loc, TraceCalc, TraceCalc Pro logo, TraceGuard, Tracer, TraceTek, VLBTV, VLKTV, VPL,

    We manage the heat you need and XTV, are trademarks of Tyco Thermal Controls, LLC or its

    affiliates.

    Armaflex is a trademark of Armacell Enterprise, GMBH. AutoCAD is a trademark of Autodesk,

    Inc. InterLock is a trademark of Hanger & Pipe Accessories, Inc. Modbus is a trademark of

    Gould, Inc. Nichrome is a trademark of Driver Harris Corporation. Panduit is a trademark of

    Panduit Corporation. Windows is a trademark of Microsoft Corporation.