8/13/2019 h2099 Emc Clariion San Copy Wp http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 1/40  EMC SAN Copy  A Detailed Review Abstract This white paper presents the features, functionality, and performance characteristics of EMC ®  CLARiiON ® SAN Copy, as well as examples for use. It outlines the benefits and functionality of SAN Copy and how it can be used to solve problems involving data replication within and between data centers. It also provides SAN Copy configuration details. September 2010

h2099 Emc Clariion San Copy Wp

Embed Size (px)

Citation preview

Page 1: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 1/40

 

EMC SAN Copy

 A Detailed Review

Abstract

This white paper presents the features, functionality, and performance characteristics of EMC ® CLARiiON®

SAN Copy™, as well as examples for use. It outlines the benefits and functionality of SAN Copy and how it

can be used to solve problems involving data replication within and between data centers. It also provides SAN

Copy configuration details.

September 2010

Page 2: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 2/40

 

EMC SAN Copy

A Detailed Review 2

Copyright © 2006, 2008, 2009, 2010 EMC Corporation. All rights reserved.

EMC believes the information in this publication is accurate as of its publication date. The information is

subject to change without notice.

THE INFORMATION IN THIS PUBLICATION IS PROVIDED ―AS IS.‖ EMC CORPORATION

MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE

INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED

WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Use, copying, and distribution of any EMC software described in this publication requires an applicable

software license.

For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com.

All other trademarks used herein are the property of their respective owners.

Part Number H2099.4

Page 3: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 3/40

 

EMC SAN Copy

A Detailed Review 3

Table of Contents

Executive summary ............................................................................................ 5 Introduction ......................................................................................................... 5 

 Audience ...................................................................................................................................... 5 Introduction to CLARiiON SAN Copy ................................................................ 5 SAN Copy concepts and definitions ................................................................. 7 SAN Copy benefits .............................................................................................. 8 

Performance................................................................................................................................. 8 Host independence ...................................................................................................................... 8 Connectivity options ..................................................................................................................... 9 

SAN Copy uses ................................................................................................... 9 Data migration .............................................................................................................................. 9 Content distribution ...................................................................................................................... 9 Disaster recovery ....................................................................................................................... 10 

SAN Copy functionality .................................................................................... 10 Supported storage systems ....................................................................................................... 10 

SAN Copy storage systems ................................................................................................... 10 SAN Copy compatible storage systems ................................................................................. 10  

SAN Copy over iSCSI ................................................................................................................ 11 SAN Copy management ............................................................................................................ 11 

Managing with Unisphere ....................................................................................................... 11 Managing with the Navisphere command line interface ........................................................ 13 Managing SAN Copy sessions across Unisphere domains ................................................... 13  Managing with Replication Manager ...................................................................................... 13 

SAN Copy full and incremental sessions ................................................................................... 14  Source LUN quiesce requirements ........................................................................................ 14 Considerations for mounting the destination LUN.................................................................. 15  

Interaction between SAN Copy incremental sessions and SnapView software ........................ 15 Reserved objects .................................................................................................................... 15 Reserved LUN pool considerations ........................................................................................ 15 Internal objects ....................................................................................................................... 15 

SAN Copy operations and management ................................................................................... 17 Create a SAN Copy session ................................................................................................... 17 Start, stop, pause, resume, remove operations ..................................................................... 17 Throttle ................................................................................................................................... 17 Latency and bandwidth control .............................................................................................. 17 Transfer of session ownership ............................................................................................... 18 Mark and unmark operations.................................................................................................. 18 Nomark operation (also known as “bulk copy”)  ...................................................................... 18 Global settings ........................................................................................................................ 19 

SAN Copy configuration .................................................................................. 19 SAN Copy zoning ....................................................................................................................... 19 SAN Copy LUN masking ............................................................................................................ 20 SAN Copy path balancing .......................................................................................................... 20 SAN Copy scalability .................................................................................................................. 21 

SAN Copy system limits ......................................................................................................... 21 

Page 4: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 4/40

 

EMC SAN Copy

A Detailed Review 4

SAN Copy over extended distances ................................................................ 22 Push and pull copy operations ................................................................................................... 23 Write acceleration ...................................................................................................................... 23 Incremental session performance over IP SAN ......................................................................... 24 

iSCSI connections ............................................................................................ 25 Interoperability .................................................................................................. 26 

LUN technologies and mobility considerations .......................................................................... 26 SAN Copy and SnapView .......................................................................................................... 29 SAN Copy and MirrorView ......................................................................................................... 29 Valid SAN Copy source LUNs ................................................................................................... 29 

SAN Copy performance .................................................................................... 30 Test configuration ...................................................................................................................... 30 Full session push performance over Fibre Channel .................................................................. 31 Incremental session update performance over Fibre Channel .................................................. 31 

Conclusion ........................................................................................................ 33 References ........................................................................................................ 33 Appendix A: Symmetrix-to-CLARiiON migration guide ................................. 34 

Zoning ........................................................................................................................................ 34 Establishing port connectivity..................................................................................................... 34 Symmetrix volume access ......................................................................................................... 34 Obtaining Symmetrix volume information .................................................................................. 35 Creating a SAN Copy session ................................................................................................... 37 Running the SAN Copy session ................................................................................................ 39  

Appendix B: SAN Copy/E for CX300 and AX100/150 ..................................... 40 SAN Copy/E management ......................................................................................................... 40 SAN Copy/E system limits ......................................................................................................... 40 

Page 5: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 5/40

 

EMC SAN Copy

A Detailed Review 5

Executive summaryEMC® CLARiiON® SAN Copy™ is an optional software application available on CLARiiON storage

systems. SAN Copy moves data to and from CLARiiON storage systems on a per-logical-unit (LUN) basis.

A CLARiiON storage system running SAN Copy can transfer data to and from other CLARiiON systems,

Symmetrix® systems, and supported third-party systems. This functionality can be used for a number of

 purposes, including data movement for consolidated business processing activities, backup to tape, backup

to disk, data warehouse refreshes, and replication of databases from one storage system to another over the

SAN without the need for host-based replication software.

IntroductionThis white paper presents the features, functionality, and performance characteristics of EMC  CLARiiON SAN

Copy, as well as examples of its use. It outlines the benefits and functionality of SAN Copy and how it can be

used to solve problems involving data replication within and between data centers. It also provides SAN Copy

configuration details.

Audience

This white paper is intended for systems integrators, systems administrators, and members of the EMC and

 partners professional services community. It is assumed that the audience is familiar with CLARiiON

storage systems and other optional applications such as SnapView™ and MirrorView™. The intent of this

 paper is to present guidelines for architecting SAN Copy-based solutions.

Introduction to CLARiiON SAN CopyEMC CLARiiON SAN Copy is a storage-system-based application that is available for certain CLARiiON

storage systems as an optional package. It enables the storage system to copy data at a block level directly

across the SAN from one storage system to another or within a single CLARiiON system. While the

software executes on a CLARiiON storage system, it can copy data from and send data to other supported

storage systems on the SAN. SAN Copy software can move data from one source to one or multiple

destinations concurrently. Figure 1 illustrates some of the ways SAN Copy can be used to move data.

Page 6: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 6/40

 

EMC SAN Copy

A Detailed Review 6

Figure 1. SAN Copy topology

SAN Copy is designed as a multipurpose replication product for data mobility, migrations, content

distribution, and disaster recovery (DR). However, SAN Copy does not   provide the complete end-to-end protection that MirrorView provides.

MirrorView is storage-system-based DR software. MirrorView replicates the contents of a primary volume

to a secondary volume that resides on a different CLARiiON storage system. When MirrorView performs

this replication to a secondary volume, all server access to the secondary volume must be initiated through

MirrorView, thus ensuring end-to-end data protection.

SAN Copy provides an efficient replication mechanism that can be used as part of a DR strategy with

Replication Manager.

Page 7: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 7/40

 

EMC SAN Copy

A Detailed Review 7

Table 1 compares MirrorView and SAN Copy.

Table 1. MirrorView and SAN Copy use case comparison

Product MirrorView SAN Copy

Storage system support Replication between CLARiiON

 primary and secondary systems

Replication between CLARiiON,

Symmetrix, and non-EMC

systems

Content distribution 1 primary to 1 secondary async; 2

secondaries sync (1:1 with con

groups)

1 source copied to up to 100

targets (50 targets for lower-end

systems)

Data protection Continuous data protection of

secondary volumes

Remote copy is available for

server access

Consistency across volumes Native consistency group support Consistency managed by the user

(such as hot backup mode) or

another application (such as EMC

Replication Manager)

SAN Copy is useful for:

Data mobility 

  Rapidly copy data — where and when you need it.

  Eliminate impact on production activities during data mobility tasks.

Data migration 

  Easily migrate data from qualified storage systems to CLARiiON CX series networked storage

systems.

Content distribution 

  Push pricing and inventory data to remote locations each day.

  Copy production data into development environments for testing new applications.

Disaster recovery 

  Protect and manage Microsoft Exchange and SQL environments via integration with EMC

Replication Manager.

SAN Copy concepts and definitionsThe following basic SAN Copy concepts and definitions will help you better understand how SAN Copy

operates. These terms are used throughout the paper:

LUN  –  Typically refers to a CLARiiON logical unit. That definition is relaxed slightly in this paper

when talking about source and destination LUNs. It may refer to a CLARiiON LUN, metaLUN, thin

LUN, SnapView snapshot, SnapView clone, Symmetrix volume, Symmetrix BCV, or a logical volume

on a third-party storage system.Source LUN  –  The LUN that will be replicated.

Destination LUN  –  The LUN to which the data will be replicated.

SAN Copy session  –  A persistent definition that consists of a source LUN and one or more destination

LUNs.

SAN Copy (hosting) storage system –  The CLARiiON storage system(s) on which SAN Copy is

installed. The SAN Copy storage system will be the initiator of the session and perform the data

transfer.

Page 8: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 8/40

 

EMC SAN Copy

A Detailed Review 8

SAN Copy port –  CLARiiON storage processor port(s) to be used by SAN Copy. It provides the

 behavior of a SAN initiator, as well as the usual target behavior.

Quiesce  –  To halt all activity on a LUN. This means no I/O in progress.

Block-level copy  –  SAN Copy reads and writes data at the block level. This means that SAN Copy

operates at the LUN level and is not aware of any partitions or file systems that exist on that LUN.

Push  –  The operation in which the SAN Copy storage system reads data from one of its LUNs and

writes that data to a destination LUN(s).

Pull  –  The operation in which the SAN Copy storage system reads data from a source LUN on another

system and writes that data to one of its LUNs.

Inter-system transfer  –  Data movement between two (or more) storage systems.

Intra-system transfer  –  Data movement within a CLARiiON storage system.

Third-party storage system  –  Refers to any SAN Copy-compatible storage system not manufactured

 by EMC.

Fibre Preferred –  A Fibre Preferred connection type allows you to search for a Fibre Channel path to

the remote LUN first; if a Fibre Channel path is not found, it searches for an iSCSI path to the remote

LUN.

iSCSI  –  Internet SCSI.

iSCSI LUN  –  The LUN that resides on an iSCSI array.

SAN Copy array  –  The array on which SAN Copy software resides.

Within Domain  –  This refers to a LUN that resides in the same Navisphere® administrative domain as

the SAN Copy array. LUNs that reside on non-CLARiiON arrays are  not  within domain.

SAN Copy benefitsSAN Copy has several benefits over host-based replication options:

Performance is optimal because data is moved directly across the SAN.

 No host software is required for the copy operation because SAN Copy executes on a CLARiiON

storage system.

SAN Copy offers interoperability with many non-CLARiiON storage systems.

Performance

The advantage of SAN Copy is that the data to be replicated only moves once across the SAN. Host-based

replication products move data twice: first from a SAN-attached storage system to the host, and then

writing the same data to another host. With SAN Copy, all processing takes place at the storage-system

level. For remote copies, SAN Copy balances sessions across available paths and has algorithms designed

for efficient link utilization. When the source and destination LUNs are on the same system, the copy

operation takes place internally and does not require any data traffic on the SAN. SAN Copy has a large

 performance advantage over host-based replication technologies because it moves data directly between

storage systems.

Host independence

The copy operation of SAN Copy does not require host CPU processing, which leaves more resources

available for applications. SAN Copy transfers are independent of the host OS or file-system type. As a

result, customers have more flexibility in their heterogeneous OS environments. SAN Copy can be used for

all data transfers rather than having to rely on different replication software for each OS.

Page 9: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 9/40

 

EMC SAN Copy

A Detailed Review 9

Connect iv i ty opt ions

SAN Copy supports connections with many non-CLARiiON storage systems, including Symmetrix and

third-party storage systems. This allows SAN Copy to be deployed in heterogeneous storage environments.

It can be used in place of a host to move data between several different storage systems where data transfer

 between them wouldn’t normally be supported. 

SAN Copy may also be used over an IP-extended SAN. This allows data to be replicated over longdistances where fibre connectivity may not be available.

SAN Copy usesSAN Copy has many uses, including but not limited to data migration, content distribution, and disaster

recovery (when used with Replication Manager).

Data mig rat ion

Data migration is the process by which data is relocated from one system to another. SAN Copy can

migrate data to and from a CLARiiON storage system.

Data migration for storage-system replacementIf upgrading to a CLARiiON CX series storage system from a previous-generation CLARiiON storage

system or third-party storage system, SAN Copy can migrate the data from one system to another.

Data migration within a single CLARiiONA storage system that hosts SAN Copy may use SAN Copy to migrate data within itself. However, since

the release of LUN Migration (in release 16), it is the optimal way to migrate LUNs within a CLARiiON

storage system, because it performs data movement without disrupting the host’s access to the data.

Data migration between storage tiersIn an environment with multiple storage tiers, SAN Copy can move data between the tiers. For example,

SAN Copy can move between tiers based on Symmetrix or third-party storage systems. It can also move

data from a tier based on CLARiiON with Fibre Channel drives to a tier based on CLARiiON with

Advanced Technology-Attached (ATA) drives.

LUN expansionSAN Copy software can copy data from a smaller-capacity LUN to a larger-capacity LUN. However,

CLARiiON metaLUNs and LUN Migration allow you to expand LUNs without disrupting applications.

Please see the white paper EMC CLARiiON MetaLUNs - A Detailed Review on EMC Powerlink ® for more

information. For a detailed description of how to expand LUNs on different operating systems, see the Host

Connectivity Guide for each operating system. For more information on strategies for migrating data to

CLARiiON storage systems, see the white paper Strategies for Migrating Data to EMC CLARiiON Storage

Systems available on Powerlink.

Content dist r ibut ion

In today’s business environment, it is common for a company to have multiple data centers in different

regions. Customers frequently need to distribute data from headquarters to regional offices and collect data

from local offices to send to headquarters. Such applications are defined as content distribution. Webcontent distribution, which involves distributing content to multiple servers on an internal or external

website, is an example of content distribution. SAN Copy is ideal for content distribution. A session can

have multiple destination LUNs. After setting up the session, data can be copied simultaneously to several

LUNs with the same management effort as copying to a single LUN.

Page 10: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 10/40

 

EMC SAN Copy

A Detailed Review 10

Disaster recov ery

SAN Copy, in combination with SnapView and Replication Manager, offers a disaster-recovery solution

for applications consolidated on CLARiiON storage systems. SnapView clones provide for local

operational recovery, while SAN Copy is used to copy data to a remote system for disaster recovery.

Replication Manager streamlines the process by coordinating with the host/application to create an

application-consistent clone, managing the copy process to the second storage system, and handling the

steps required in the event of a recovery.

SAN Copy functionalityThis section describes SAN Copy features and functionality.

Suppor ted storage systems 1  

The following sections describe the storage systems capable of running SAN Copy software, as well as

those capable of participating in SAN Copy sessions.

SAN Copy storage systems

CLARiiON storage systems that are qualified to host SAN Copy software are called hosting storage

systems. The hosting system will be the one initiating SAN Copy sessions. Qualified hosting systems are:

All CX4 systems

All CX3 systems

CX400/500/600/700

AX4-5 and AX4-5F8 expanded models2 

CX300 and AX100/150 (SAN Copy/E only3)

SAN Copy compatible storage systems

These storage systems cannot host the SAN Copy application, but they can participate in SAN Copy

sessions by serving as a source or a destination4

. SAN Copy compatible storage systems include:

CLARiiON: CX300/200, AX100/150

AX4-5 and AX4-5F8 basic models5 

Symmetrix: 8000 series, DMX-2, DMX-3, VMAX™ 

Select third-party storage systems6: (Please refer to the EMC SAN Copy .pdf document available via

E-Lab™ Navigator at EMC.com for a complete list.)

1 Refer to E-Lab Navigator for the most recent support information. Under the PDFs and Guides tab,

choose the SAN Copy PDF.2 AX4-5 series refers to the Fibre Channel models only. The expanded model requires a dual-SP

configuration with full Navisphere Manager.3

 Appendix B, ―SAN Copy/E for CX300 and AX100/150,‖ provides a detailed description of SAN Copy/Efunctionality.4 Since the SAN Copy application is not running on these storage systems, it cannot be used to copy LUNs

within these storage systems.5 The AX4-5 series basic model refers to the Fibre Channel host connection array with the NaviExpress

graphical user interface.6 Information on setting up SAN Copy with third- party storage systems is provided in the ―SAN Copy

Configuration Requirements for Non-EMC Storage Systems‖ section of the most recent SAN Copy Release

 Notes.

Page 11: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 11/40

 

EMC SAN Copy

A Detailed Review 11

HP: EMA12000, EMA16000, ESA12000, EVA3000, EVA4000, EVA5000, EVA6000,

EVA8000, EVA8100, HSG80, MA8000, MSA−1000, MSA1500, RA8000, XP−1024,

XP−12000, XP−128, XP−512 

IBM: DS8300, DS8100, DS6800, DS4800, DS4500, DS4400, DS4300, DS4100, DS3400,

FAStT500, FAStT600, FAStT700, FAStT900, 2105-F20, 2105-E20, 2105-800

HDS: 9990, 9980V, 9970V, 9960, 9920, 9910; TagmaStore AMS1000, AMS200, AMS500,

WMS100; Thunder 9520v, 9530v, 9570v, 9585v

3PAR InServ: E200, S400, S800

Sun: StorEdge 9990, T3/T3+

SAN Copy over iSCSI

SAN Copy over iSCSI is supported between FC/iSCSI systems. FC/iSCSI storage systems include all CX4

series systems and the CX3-10 through CX3-40. The storage systems must also be running a minimum of

FLARE® release 26. It is possible to have iSCSI connections between CX3 FC/iSCSI systems and CX300i

and CX500i storage systems. These connections are valid for SAN Copy use only (not MirrorView).

The SAN Copy Wizard has been enhanced to support SAN Copy over iSCSI. If both Fibre Channel and

iSCSI connectivity exists, you can choose the desired connection type. As long as connectivity exists over

the preferred link, the wizard will perform the setup and configuration steps.

SAN Copy can maintain two connection types (Fibre Channel and iSCSI) to the same destination. Fibre

Channel, iSCSI, and Fibre Preferred are the possible connection types. If your storage system is configured

with Fibre Channel as well as iSCSI connections, the wizard will automatically choose Fibre Preferred as

the connection type. The connection type can also be modified in Session properties and when creating a

LUN. Additional infor mation for advanced users is available in the ―iSCSI connections‖ section. 

SAN Copy management

SAN Copy software can be managed in several ways, including:

 Navisphere Manager

 Navisphere command line interface (NaviSecCLI)EMC Replication Manager

Managing with Unisphere

Unisphere™ has been introduced as the replacement for Navisphere Manager in release 30. Unisphere is

unified management software that serves as the management interface for CLARiiON, Celerra ®, and

complementary products such as RecoverPoint and Replication Manager. As soon as the SAN Copy

enabler is installed on a CLARiiON storage system, functionality is added into Unisphere that allows users

to create, execute, and control SAN Copy sessions. Unisphere can manage CLARiiON storage systems

running release 19 or later.

Unisphere uses a task-based management approach. Most options are available via a list of tasks in the left

 pane, while details of the specific area of management are provided in the right pane as seen in Figure 2. Similar to Navisphere, right-click object menus are available for objects in the table.

Page 12: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 12/40

 

EMC SAN Copy

A Detailed Review 12

Figure 2. SAN Copy sessions table in Unisphere

SAN Copy offers the user views from two perspectives: the SAN Copy sessions table as shown in Figure 2

and the SAN Copy LUNs table as shown in Figure 3. 

Figure 3. SAN Copy LUNs table

You can create new sessions with an easy-to-use wizard that you can launch from the left-hand pane or

right-click menu. The SAN Copy Wizard in Unisphere is largely unchanged from the version in Navisphere

Manager. Figure 4 shows a sample screenshot of Unisphere’s SAN Copy Wizard. The wizard guides you

through the process of creating the SAN Copy session by selecting the server LUN that will be the source,

then selecting a viable destination LUN.

Page 13: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 13/40

 

EMC SAN Copy

A Detailed Review 13

Figure 4. SAN Copy Wizard, Select Storage Sources

More detailed information about Unisphere is available in the white paper  Introducing EMC Unisphere: A

Common Midrange Element Manager on Powerlink.

Managing with the Navisphere command line interface

SAN Copy operations can also be executed using NaviSecCLI. All CLARiiON storage systems come with

the Navisphere CLI. It is a command line interface that enables expert users to write scripts for configuring,

monitoring, and managing CLARiiON storage systems. This allows you to automate SAN Copy

operations. Details can be found in the SAN Copy Command Line Interfaces Reference on Powerlink.

Managing SAN Copy sessions across Unisphere domains

Prior to release 19, all CLARiiON storage systems involved in the same SAN Copy session were required

to be in the same Navisphere management domain in order to see LUN information on each system. If a

SAN Copy session were to be created across domains, the user would have to obtain the WWNs of any

remote LUNs and enter them into the Navisphere GUI or CLI. With the introduction of Navisphere

multidomain management in release 19, it is possible to easily manage SAN Copy sessions that span

 Navisphere domains. The white paper Domain Management with EMC CLARiiON Storage Systems 

 provides more information on multidomain management. Unisphere can be used for multidomain

management of any systems running R19 or later.

Managing with Replication Manager

EMC Replication Manager simplifies the management of EMC SAN Copy and EMC SnapView software.RM automates many tasks, including the creation and execution of SAN Copy sessions –  tasks that may

otherwise require custom scripting. It also provides a graphical user interface that establishes replicas from

the application’s point of view. Figure 5 shows an example of an incremental session being created from

clones of a local Microsoft Exchange database.

RM supports Microsoft's Virtual Shadow Copy Service (VSS) architecture, allowing you to make hot

 point-in-time Exchange copies without disrupting your production server. Replication Manager also has

interfaces to SQL, SharePoint, Oracle, DB2, and VMware and can be integrated with custom scripts to

simplify management of SAN Copy in any application environment.

Page 14: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 14/40

 

EMC SAN Copy

A Detailed Review 14

For more information on EMC/Microsoft Exchange DR solutions, see  EMC CLARiiON Storage Solutions:

 Microsoft Exchange 2007: Best Practices Planning  and EMC CLARiiON Storage Solutions Microsoft

 Exchange 2003 Best Practices: Storage Configuration Guidelines. For more information on SQL, see the

white paper EMC Replication Manager and Microsoft SQL Server - A Detailed Review  and for more on

Oracle, read EMC Replication Manager Integration with Oracle Database Server- A Detailed Review.

Figure 5. Creation of an incremental session using Replication Manager

SAN Copy ful l and incremental sessions

SAN Copy supports the incremental update of destination LUNs with only the data that has changed on thesource since the last update. This gives SAN Copy users a choice of two session types: full and

incremental.

A full  session copies the entire contents of the source LUN to the destination LUN(s) every time the

session is executed. Full sessions can be a push or a pull with any qualified storage system. Users

usually use a full SAN Copy session for migrating data to and from a CLARiiON storage system.

An incremental session requires a full copy only once. This is called an initial synchronization. After

the initial synchronization, each incremental update copies only the data that has changed on the source

LUN since the beginning of the last update. For incremental sessions the source LUN must reside on

the SAN Copy storage system, but the destination LUN can reside on any qualified system. Users

usually use incremental sessions for ongoing backups, such as daily sales updates.

Source LUN quiesce requirementsWhen creating a full session data is copied directly from the source; therefore, in order to create a

consistent copy of the data, I/O must be quiesced on the source for the duration of the session. To allow the

 production LUN to be active during the SAN Copy transfer, a full session may be created using a

SnapView snapshot or a fractured clone as the data source.

With incremental sessions, it is not necessary to keep the host I/O quiesced during the entire session.

Before a transfer, host buffers should be flushed, and I/O should be momentarily quiesced. On Windows,

when you manually control SAN Copy session updates with Navisphere on Windows, you can use admhost

to quiesce the host and flush the buffers. If this is not possible, the destination LUN will be a crash-

Page 15: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 15/40

 

EMC SAN Copy

A Detailed Review 15

consistent image at the end of the transfer. Alternatively, if you use Replication Manager to manage the

SAN Copy session, Replication Manager will work with server applications to facilitate application-

consistent copies.

Considerations for mounting the destination LUN

Once a LUN is designated as a destination LUN of an incremental session, it should not be mounted by a

host. SAN Copy does not track changes on the destination LUN. For example, if a destination LUN is

mounted and changed due to host I/O, SAN Copy will not be aware of these changes. Even mounting a

read-only file system is not guaranteed to be read-only to the disk. File systems may write metadata out to

the disk, and that metadata will be inconsistent with what will be copied over in the next update. In any

case where the destination LUN is modified, a full synchronization from source to destination is required to

 bring the destination to a consistent, known state.

One of the following methods can be used to access the data on a destination LUN:

Create a SnapView clone of the destination LUN, fracture it, and mount the clone.

Create a SnapView snapshot of the destination LUN and mount it.

 Note: During a SAN Copy transfer, an active SnapView session or unfractured clone may reduce transfer

throughput.

Interact ion between SAN Copy in cremental session s and

SnapView softw are

A SAN Copy incremental session internally uses SnapView to create a snapshot of the source LUN, and

actually reads from the snapshot during the update, so that there is a consistent point-in-time view of the

data being transferred. The following sections describe the objects managed by SAN Copy incremental

sessions and their roles.

Reserved objects

When an incremental session is created, a reserved SnapView snapshot and SnapView session are created

as well. These reserved objects are visible via Navisphere Manager or Navisphere CLI, but cannot bemanipulated or used by the end user. When the incremental SAN Copy session is destroyed, these reserved

objects are automatically destroyed.

Reserved LUN pool considerations

The reserved SnapView sessions allocate LUNs from a shared resource called the reserved LUN pool.

Before creating an incremental session, storage must be allocated to the reserved LUN pool. The number

and size of these LUNs will depend on the rate of the change on the source LUN during the update

operation. EMC  CLARiiON Reserved LUN Pool Configuration Considerations provides best practices on

configuring the reserved LUN pool.

Internal objects

During a SnapView session, two bitmaps, called the tracking  map and transfer  map, are created internally

to track the changes on the source LUN and to track the progress of transfer of the changed data to the

destination LUNs. This information is saved on the reserved LUNs. The space required for storing these

chunk maps entries is negligible; typically, it adds about 0.02 percent of the source LUN size.

Additional definitionsRegion  –  The smallest amount of sequential data that SAN Copy can track and transfer. For release 19 and

later, the value is 2 KB; for releases prior to 19, the value is 64 KB.

Page 16: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 16/40

 

EMC SAN Copy

A Detailed Review 16

Copy on first write  –  While a copy operation for an incremental session is running, if a write is received

for the source LUN for a region that is designated to be transferred but has not yet done so, the region (and

 possibly data surrounding it) is copied to the SnapView session’s reserved LUN(s). Copy-on-first-write

operations work on 64 KB chunks.

Chunk   –  The amount of data that is copied in a copy-on-first-write operation (64 KB).

Tracking mapThe tracking map is a persistent disk-resident bitmap that is used to keep track of which regions need to be

transferred in the next transfer from the source LUN. When a write changes a region, a bit is set in the

tracking map indicating the change. By default, SAN Copy incremental sessions mark all regions for

transfer to perform a full synchronization the first time it is run. After the initial sync, only regions

receiving writes will be designated for transfer.

Transfer mapWhen the transfer begins, the current tracking map is frozen, and is then designated as the transfer map. (A

new tracking map is created to track changes until the next transfer.) The transfer map denotes the regions

that need to be transferred in the current transfer. As data is transferred over to the destination LUN(s), the

 bits are changed from 1 to 0 to indicate that the corresponding region has been transferred. If there are

multiple destinations, the transfer map keeps the bit as 1 until all the destinations have received a copy of

the region.

For example, a 4 KB host write would result in two marked 2 KB regions (for FLARE ® 19 and later) or onemarked 64 KB region (for FLARE 17 and earlier). At transfer time, sequential regions are coalesced to

form writes of up to 64 KB. In this example, SAN Copy would generate writes of 4 KB and 64 KB,

respectively, to the destination. With host I/O profiles characterized by small I/O sizes, the smaller

granularity in release 19 results in lower bandwidth usage, benefiting low-bandwidth intersite links, such as

(T1/T3).

Page 17: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 17/40

 

EMC SAN Copy

A Detailed Review 17

SAN Copy operat ions and management

SAN Copy-related operations are managed either by the Navisphere Manager GUI or by NaviSecCLI.

The core operations are:

Create a SAN Copy session.

Start/Stop/Pause/Resume/Remove a SAN Copy session.

Throttle a SAN Copy session.

Create a SAN Copy session

A SAN Copy session defines the LUNs involved in the relationship, as well as other session parameters.

 Navisphere Manager’s SAN Copy Create Session Wizard walks the user through the process of selecting a

source, one or multiple destinations, and the initial throttle value for the session. Each session is unique to

each storage processor (SP) and is stored persistently in the storage-system database. Once defined, the

SAN Copy session can be started any number of times subsequently. You can do this with Navisphere

Manager, NaviSecCLI scripts, or Replication Manager.

Session attributes include:

SAN Copy session name: user-defined name used for future reference

Source and destination LUN(s)

Throttle value

Latency and bandwidth control for incremental sessions

In release 19 and later, provisions are available that give SAN Copy the ability to address LUNs on select

HDS and IBM Shark storage systems as source or destination LUNs. These storage system models require

a port WWN and a LUN number (rather than the standard LUN WWN) to address their LUNs. SAN Copy

has modified both the Navisphere GUI and the Navisphere CLI to accommodate these nonstandard

requirements.

Start, stop, pause, resume, remove operationsTo start a SAN Copy session, click the start button at the bottom of the SAN Copy sessions table, right-

click the session in Unisphere, or issue the appropriate NaviSecCLI command. A currently active session

can be stopped (or paused), and then restarted. When a session is stopped, it has to be restarted from the

 beginning. When a session is paused, you can resume the session at the point at which you paused. The

remove operation destroys the session. These tasks can be automated using Replication Manager.

Throttle

This parameter is defined on a per-session basis. Throttle values range from 1 to 10, where 1 is the

slowest, 10 is the fastest, and 6 is the default value. When throttle is set to 10, the system reads from the

source and writes to the destination as quickly as it can, which causes many system resources to be

allocated to that session. SAN Copy reduces the internal buffer size and inserts longer delays between I/Os.

This allows the session to run with less performance impact on other applications. The throttle value can bechanged dynamically after the session is created and during the progression of the session. For example,

you can start a session with the throttle set to 6 and, in the middle of the session, increase the throttle to

10.When a new session is started after completion of this session, the default throttle value of 6 is retained.

Latency and bandwidth control

SAN Copy incremental sessions have enhanced algorithms for link and network resource management. The

goal is to:

Page 18: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 18/40

 

EMC SAN Copy

A Detailed Review 18

Maximize utilization of the available link bandwidth.

Allocate buffer space to deal with high-latency lines and to ensure most efficient memory utilization.

When an incremental session is created, the available bandwidth and latency7 can be specified.8 These two

values are used to calculate and allocate an optimal buffer configuration for the session. The bandwidth

value is required, but the value for the latency parameter can be left at the default value, in which case the

SAN Copy driver will measure latency by sending test I/O to the destination.

Transfer of session ownership

When a SAN Copy session is created, it is owned by the SP that currently owns the LUN on that system. If

that LUN is trespassed to the other SP, the SAN Copy session will pause if it is currently running. The

SAN Copy session must be transferred to the other SP (right-click on the session and choose transfer SP

owner) before it can be restarted. This will allow a SAN Copy session to continue if the original SP is

rebooted or it loses the paths that were available to SAN Copy.

Mark and unmark operations

The mark  and unmark operations are specific to SAN Copy incremental sessions. These operations are

useful in a situation where the customer wants to create a snapshot of the source LUN at a point in time and

 perform the transfer at a later time.

Mark operationA mar k operation is SAN Copy software’s mechanism to communicate with SnapView software and create

a snapshot of the source LUN. If an incremental SAN Copy session is marked, its mark time is displayed in

Unisphere as an attribute of the session in the SAN Copy tables.

The mark operation is executed in one of the two ways:

The SAN Copy software automatically invokes the mark operation during initial synchronization and

at the beginning of an incremental update operation.

A user explicitly initiates the operation as desired.

Unmark operationIn an unmark operation, SAN Copy destroys the snapshot that was created during the mark operation,

discarding any changes. Regions in the transfer map are added back into the tracking map so that they will be transferred on the next update.

The unmark operation is executed in one of the two ways:

The SAN Copy software automatically invokes the unmark operation after SAN Copy successfully

completes a session transfer. In this case, there are no marked regions to merge back into the tracking

map.

Before a marked session is started, a user can explicitly initiate the operation as desired to discard a

 previously created point-in-time snapshot of the source LUN created with a previous mark operation.

Nomark operation (also known as “bulk copy”)

When performing the initial synchronization of an incremental session, there may be an effect on the

response times for host I/O if a lot of copy-on-first-write operations are taking place. Since some initialsynchronizations can take a long time, it may be desirable to minimize the performance impact while the

7 When creating a session in Navisphere Manager, latency can be set by accessing the properties dialog box

of an existing incremental session.8  You can specify the interconnection bandwidth when you create the session using the SAN Copy user

interface. After the session is created, you can specify the latency in the session properties dialog box. If

you use the SAN Copy CLI, bandwidth and latency can be specified as parameters to the

sancopy – create –  incremental command.

Page 19: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 19/40

 

EMC SAN Copy

A Detailed Review 19

transfer is active. This can be done by using the nomark  operation, which skips copy-on-first-write

operations during the initial synchronization.

Since the source LUN may be open to host I/O during the transfer and a static point in time is not being

 preserved with copy on first write, a bulk copy will result in destination LUNs being temporarily in an

inconsistent state with respect to the data on the source LUN. Once the transfer completes successfully, an

incremental update session must be executed to make all destinations consistent.

This feature is available via CLI only. A bulk copy operation can only be executed on an unmarked

incremental session. After creating the session, run the following Navisphere CLI command:

sancopy –start –name sessionName –copywholelun –nomark all

Global settings

These are global settings for each SP. Several parameters can be set to tune the performance of SAN Copy

sessions. However, the defaults have been carefully researched, and benefit most configurations in most

environments.

Number of concurrent sessionsThis is the number of full and incremental sessions that can be transferring data at the same time on that SP.

Additional sessions that are started are queued for transfer.Checkpoint intervalCheckpointing applies to full sessions only, as incremental sessions have built-in checkpointing via the

transfer map. The checkpoint records the progress of a full session during the update by storing a pointer

referencing the number of the last block successfully copied from the source to the destination. The default

checkpoint interval is 10 minutes and is user adjustable from 5 to 90 minutes. If a SAN Copy operation is

interrupted — for example, if the destination LUN becomes temporarily inaccessible — the SAN Copy

operation can be restarted manually from the last checkpoint when the LUN becomes available again. This

checkpoint interval mechanism does not apply to incremental sessions, where progress is checkpointed at

each write via the transfer map.

Buffers per session and buffer sizeThese parameters define the amount of memory SAN Copy full sessions allocate to queue outgoing writes.

For incremental sessions, SAN Copy will automatically determine the correct number of buffers to use and

their size to maximize the throughput of the available transfer medium. These values should only be

changed if the copy is between storage systems connected over a local SAN, in which case these values

may be increased to their maximum values. By buffering more data blocks into memory, disk response

times become less of a bottleneck.

SAN Copy configurationBefore SAN Copy sessions can be created, supporting software packages must be installed on the

CLARiiON storage system, and connections must be established between the storage systems that will be

 participating in the sessions.

SAN Copy zoning 9  

Guidelines for SAN Copy zoning are available in Navisphere Manager’s online help. To read these

guidelines, open the manager’s online help and follow this path: SAN Copy > Configuring SAN Copy >

Zoning Recommendations. (To download this help, open Powerlink and follow this path: Support

9 MirrorView and SAN Copy cannot share the same front-end ports. If MirrorView is enabled on the

system, SAN Copy will not use the same ports. If MirrorView is not enabled, SAN Copy can use any front-

end port.

Page 20: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 20/40

 

EMC SAN Copy

A Detailed Review 20

>Technical Documentation and Advisories > Software ~ J-O ~ Documentation >

Navisphere Management Suite > Maintenance/Administration.)

EMC recommends that you only place one initiator (host initiator or SAN Copy initiator) in each zone.

There are two exceptions to this rule, which are explained in the SAN Copy zoning guidelines.

Each SAN Copy port that will be participating in a SAN Copy session must be zoned to one or more ports

of each SP on the destination storage system(s). At least one zone is necessary between two storage

systems that will participate in a session. We recommend that you have at least one zone per SP pair.

SAN Copy LUN masking

Each front-end port in a SAN Copy storage system is a dual-mode port. When the port is participating in a

copy session, it acts as an initiator to the destination storage system. When the host initiators are using the

 port to transfer I/O, the port acts as a target to the host initiator.

Once the appropriate ports have been zoned, the SAN Copy storage system’s initiators must be added to the

SAN Copy storage group. It may be necessary to select Update Connections in the SAN Copy menu to

force the SAN Copy storage system to log in to every storage system to which it is zoned. Each port of the

SAN Copy storage system appears as a separate ―host‖ to destination storage systems. 

You can then assign SAN Copy initiator ports to storage groups on the destination storage system, as

shown in Figure 6. Multiple SAN Copy ports can be assigned to the same storage group. You can assign a

SAN Copy port to an existing storage group or you can cr eate storage groups for SAN Copy’s specific

access. For example, you can create a storage group for each SAN Copy port and add LUNs to be used by

the port to the storage group.

Figure 6. SAN Copy connection to a storage group

SAN Copy path b alancing

SAN Copy allows the use of all available ports of a local SP to perform data movement. An available port

is defined as one that is zoned and masked to have access to the destination LUN. In the case of a CX4-960,for example, all eight FC ports and four iSCSI SP ports in the default configuration could be used for SAN

Copy sessions. Any Fibre Channel or iSCSI ports added later can also be used for SAN Copy.

When a user starts a session, SAN Copy selects the local SP port of the preferred type (FC/iSCSI) with the

fewest SAN Copy sessions running on it. Next, it randomly picks any port on the destination storage

system through which it can see the destination LUN. The ports and the path remain unchanged for the

duration of the session. If a session is stopped — either by the user or due to hardware failure — it might take

a completely different path when restarted. Multiple SAN Copy sessions can share the same port, though

this will only take place when all available ports are already in use.

Page 21: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 21/40

 

EMC SAN Copy

A Detailed Review 21

Optimal load balancing for SAN Copy is achieved by balancing total destination LUN capacities between

the two SPs. For example, if 4 TB of data is to be migrated, 2 TB of destination LUNs should be owned by

SPA, and the other 2 TB should be owned by SPB.

SAN Copy scalabi l i ty

SAN Copy scales up to storage-system-specific maximums on the number of sessions that can be runconcurrently and the number of sessions that can be defined. In some cases, these limits are shared with

other CLARiiON applications.

SAN Copy system limits

Table 2 and Table 3 show various limits associated with SAN Copy. For example, the Maximum

Destinations Per Session column indicates the limit on the total number of LUNs to which a source LUN

can be copied. These limits are for the entire storage system and they are evenly split over the two SPs. The

maximum number of defined sessions on all CX3 and CX4 platforms is 900.

Table 2. CX4 series SAN Copy limits

Storage system CX4-960, CX4-480 CX4-240, CX4-120

Maximum concurrentsessions

16 8

Maximum destinations per

session100 50

Maximum incrementalsource LUNs

512 (Release 29)

100 (Release 28)

256 (Release 29)

50 (Release 28)

Maximum definedincremental sessions2 

912 (Release 30)

300 (Releases 28-29)

512 (Release 30)

150 (Releases 28-29)

Maximum incrementalsessions per source LUN2 

8 8

1 These limits include MirrorView/A images and SnapView snapshot source LUNs in addition to the

incremental SAN Copy logical units. The maximum number of source LUNs assumes one reserved LUN

assigned to each source LUN.2 These limits include MirrorView/A images and SnapView sessions in addition to the incremental SAN

Copy sessions.

Page 22: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 22/40

 

EMC SAN Copy

A Detailed Review 22

Table 3. CX3 series and AX4 series SAN Copy limits

Storage system

CX3-80, CX3-40,

CX3-40c, CX700, CX600

CX3-20, CX3-20c,

CX3-10, CX500, CX400

AX4-5,

AX4-5F8

Maximum concurrentsessions10  16 8 4

Maximum destinations persession 100 50 50

Maximum incremental

source LUNs11  100 50 64

Maximum definedincremental sessions 300 150 25

SAN Copy over extended distancesFor implementations over extended distances, users may want to extend their fabric by using protocol

converters to send Fibre Channel frames across the IP WAN.

To get the best performance when implementing SAN Copy over IP, consider these performance factors:

 Network performance (network latency, bandwidth, and quality)

Compressibility of data

SAN Copy operation (push versus pull copy)

Write acceleration

 Network performance and compressibility of data are outside the scope of this paper. Write acceleration

and whether a push or a pull are being performed do have performance effects specific to SAN Copy.

10 Running multiple SAN Copy sessions can improve the overall transfer rate; however, it can also slow

down other active host I/O during the copy session.11 This total is shared with MirrorView/Asynchronous and SnapView. Each source LUN for these

applications requires at least one LUN from the reserved LUN pool. This number is actually the total

number of LUNs that can be allocated to the reserved LUN pool.

Page 23: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 23/40

 

EMC SAN Copy

A Detailed Review 23

Push and pul l copy o perat ions

The SCSI protocol requires one round trip for a read and two round trips for a write as shown in Figure 7.

The higher the latency of the connection between systems, the more noticeable the impact of the extra

round trip is. Therefore, when you use SAN Copy over extended distances (higher latencies), a pull

operation (reads) is generally faster than a push operation (writes).

Figure 7. Pull versus push operations with SAN Copy

Write acc elerat ion

To optimize data copy operations over IP, some protocol converters implement a technique called write

acceleration. Instead of the standard command/response communications — which generate four round trips

over the WAN for each write operation and incur the resulting latency delays — the standard

command/response sequence is modified so that the interleaving communications do not travel over the

WAN. Instead, a local acknowledgment to the initiating storage system is spoofed by the local protocol

converter. In other words, the XFR Ready does not traverse the IP wire, allowing data to be sent to the

destination sooner, as illustrated in Figure 8.

Figure 8. Write acceleration technology via protocol converters

Although the interleaving messaging is modified, the actual status generated by the successful completion of the

entire data transfer is returned to the initiator  —  thus ensuring data integrity.

Page 24: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 24/40

 

EMC SAN Copy

A Detailed Review 24

Table 4 compares the measured effects of write acceleration and push and pull on SAN Copy throughput

for full sessions. These transfers were performed over a Gigabit IP network with simulated latency. Source

and destination LUNs were both on dedicated disks.

The experimental results support the theories stated previously. On a low-latency link, write acceleration

had no benefit and neither did push or pull. On a higher-latency link, write acceleration made a significant

difference and resulted in throughput similar to a pull operation at the same latency. Without write

acceleration, a pull operation was about twice as fast as a push.

Table 4. Effects of write acceleration and push and pull on SAN Copy throughput

Latency (ms) Write accel Push and pull throughput

0 N/A Similar

50 ON Similar

50 OFF Push takes appoximately twice as much time as pull

and write acceleration*

*The push operation takes twice as much time because it requires twice as many transfers.

Incr emental session performance over IP SAN  The following example demonstrates the performance of incremental SAN Copy, and its impact on the

response time performance of an OLTP application, when the source and destination storage systems are

connected over an IP-extended SAN via a T3 line. The storage system test configuration consisted of two

CLARiiON CX3-80 systems, each connected to a McData Eclipse 1620 SAN Router multiprotocol switch,

as shown in Figure 9. Data compression and write acceleration were enabled on the switches to increase

throughput and reduce latency. A 50 ms delay was added to the 45 Mb/s T3 line between the switches to

simulate a 2,500-mile separation.

Page 25: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 25/40

 

EMC SAN Copy

A Detailed Review 25

McData

Switch(iFCP)

T3

Line Speed

1 Gb/s

FC

POWERF AULTDATAALARM POWERF AULTDATA ALARM

T3

Line Speed

1 Gb/s

FC

The iFCP protocol

enables the use of 

IP routing between

separate SANs

SAN Copy Source Destination

McData

Switch(iFCP)

McData

Switch(iFCP)

McData

Switch(iFCP)

T3

Line Speed

1 Gb/s

FC

POWERF AULTDATAALARM POWERF AULTDATA ALARM

T3

Line Speed

1 Gb/s

FC

The iFCP protocol

enables the use of 

IP routing between

separate SANs

SAN Copy Source Destination

T3

Line Speed

1 Gb/s

FC

POWERF AULTDATAALARM POWERF AULTDATA ALARM

T3

Line Speed

1 Gb/s

FC

The iFCP protocol

enables the use of 

IP routing between

separate SANs

SAN Copy Source Destination

McData

Switch(iFCP)

McData

Switch(iFCP)

 

Figure 9. Test configuration: SAN Copy incremental updates over IP SAN

It should be noted that the duration of a transmission is a function of the amount of data to be transmitted

and type of line (T3, 100 Mb, 1000 Mb) that is used. IP extender features such as compression, fast/smart

writing, and larger receive window sizes can reduce the duration of the update. The compression feature

typically reduces the data to half of its original size. The fast/smart feature reduces the impact of round trip

time (update I/O reduced from 2 to 1). Larger receive window sizes allow for concurrent transmission of

more data.

Please note that in FLARE 26, when native ISCSI was used, rapid degradation occurred over distance because native iSCSI lacks fast writing capabilities. In McData 1620, using larger windows and fast write

resulted in higher throughput as latency increased. Changing bandwidth latency settings allows fine tuning

of buffer configuration for better bandwidth utilization.

iSCSI connectionsiSCSI connections define the initiator/target pairs for iSCSI remote replication between CLARiiON storage

systems. Similar to zoning in a Fibre Channel environment, they determine which target the initiators log in

to. Since all necessary iSCSI connections are automatically created with the SAN Copy Wizard or the SAN

Copy Connections dialog box, explicit management of iSCSI connections for SAN Copy is a rare scenario.

To configure and start an ISCSI replication session, you must configure the iSCSI connection set. A

connection set is a set of information used by a CLARiiON iSCSI initiator to establish a replication sessionwith an iSCSI target. A connection set consists of a unique user-defined name, credentials usage

(connection specific, array-shared, or none), one or more connection paths, and an optional username and

 password.

You can create iSCSI connections in two ways –  using the Navisphere Wizard or manually. EMC strongly

recommends that you create the connections sets using the SAN Copy Create Session Wizard, since the

wizards automatically configure the appropriate connection sets using default values. 

Release 29 adds support for VLAN tagging, which allows you to configure several virtual ports on each

 physical iSCSI port. Enabling VLAN tagging is optional on a per-port basis. When enabled, up to eight

Page 26: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 26/40

 

EMC SAN Copy

A Detailed Review 26

virtual ports can be configured per 10 Gb/s iSCSI port and up to two virtual ports can be configured per

1 Gb iSCSI port. iSCSI connections are defined per physical front-end port for ports without VLAN

tagging enabled or per virtual port for ports with VLAN tagging enabled.

The current release of the SAN Copy Wizard does not add the iSCSI initiator ports to the destination

storage group. You must exit the wizard and use the management software to add the iSCSI initiator ports

to the destination storage group. The wizard will prompt you when this needs to be done. Return to the

wizard after verifying that the ports were successfully added to the storage group.

Use Unisphere or Navisphere Manager to register the copy ports with the remote storage systems by

 performing the following steps:

In Unisphere, go to the Replicas page. In the Configuration and Settings Task  list, click Update

Connections.

For Navisphere, right-click the icon for the SAN Copy storage system in the Enterprise Storage

Window. Then select SAN Copy > Update Connections.

Each copy port registers with each storage system to which it has a connection. Then, the software adds a

record for each copy port to the storage system’s host initiator table. Navisphere Manager displays an entry

for each registered copy port in the Connectivity Status dialog box and the SAN Copy Summary dialog

 box. For the LUNs to be accessible to the copy ports, you must connect the ports to the storage groups in

which the LUNs reside. When connecting to the storage group, you can select all the available SP ports

with valid connections to that particular storage group. You can also select specific ports.

For more information about connecting copy ports to CLARiiON storage groups, please refer to

 Navisphere Manager’s online help by following this path: SAN Copy > Configuring SAN Copy > SAN

Copy over iSCSI > Zoning Recommendations.

(To download this help from Powerlink, follow this path: Support > Technical Documentation and

Advisories > Software ~ J-O ~ Documentation > Navisphere Management Suite >

Maintenance/Administration.) 

InteroperabilitySAN Copy can be used with many CLARiiON LUN and replication technologies. The following sections

address common interoperability questions at a high level. For each case, there are documents that providemore specific and detailed implementation guidelines. Those documents should always be consulted when

designing a solution.

LUN techno logies and mobi l i ty considerations

Pool LUNsCLARiiON LUNs can be deployed as RAID group LUNs or pool-based (thick or thin) LUNs. RAID group

LUNs offer a high degree of control of data placement and are used for the most performance-demanding

environments. Pool-based LUNs offer intelligent and automated data placement, auto tiering, and capacity

on demand. Any or all LUN types can coexist in a CLARiiON storage system. CLARiiON LUN Migration

allows each LUN type to be migrated to different physical disks and/or LUN types, while remaining online

for applications. For detailed information on pool-based LUNs, refer to the  EMC CLARiiON Virtual

 Provisioning  white paper on Powerlink.

Pool-based LUNs consist of thick LUNs and thin LUNs. Pools offer automatic implementation of best

 practices and automation of basic capacity allocation tasks. The consumed capacity of a pool LUN defines

the amount of physical capacity that has been allocated to the LUN. User capacity represents the server-

visible capacity of a pool LUN. Thick LUNs consume their total user capacity plus a minimal amount for

metadata from the pool at the time of creation. Therefore thick LUNs are the pool-based equivalents of

traditional, RAID group LUNs. Thick LUNs are intended for applications with higher performance

requirements, while offering the ease-of-management features of pools. Thick LUNs are available in

release 30 and are supported by all CLARiiON replication products.

Page 27: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 27/40

 

EMC SAN Copy

A Detailed Review 27

Thin LUNs were introduced in release 28.5 and remote replication capabilities for thin LUNs were

introduced in release 29. Thin LUNs use a capacity-on-demand model for allocating physical disk capacity.

Subscribed capacity is the total user capacity for all  of the LUNs in a pool. Subscribed capacity can exceed

the total physical capacity of the pool when thin LUNs are deployed. When creating a SAN Copy session

of a thin LUN, the user capacity is used to determine which LUNs are eligible as source/destination pairs.

When replicating from a thin LUN source to a thin LUN destination with incremental SAN Copy, only the

consumed capacity of the thin LUN is replicated. Full SAN Copy sessions operating in a pushconfiguration also preserve the thin attributes of the source and destination LUNs. When full SAN Copy

sessions operate in a pull configuration to thin LUN destinations, the LUN will remain thin when running

on release 30. Thin LUN destinations are fully consumed on earlier versions.

There is one special case to consider. LUNs on storage systems running release 28.5 and release 29 can

replicate between one another. Thin LUNs were introduced in release 28.5, but the ability to replicate them

with SAN Copy was introduced in release 29. If a thin LUN destination is running on release 28.5, it will

 be fully consumed. To maintain the thin attributes of the thin LUN, both systems must be running release

29 or later.

It is possible to replicate a thin LUN to a thick LUN, traditional LUN, or metaLUN. The user capacity for a

thin LUN must be equal to or less than the user capacity of the target LUN. Zeros are written to the

destination for areas of the thin LUN that have yet to be allocated. When performing a SAN Copy push of a

thin LUN to a non-CLARiiON thin LUN, on Symmetrix or third-party vendor systems, the destination thinLUN will become fully consumed.

It is also possible to replicate a thick LUN, traditional LUN, or metaLUN to a thin LUN. For remote pull

SAN Copy sessions running on release 30, the destination thin LUN will remain thin. This method can be

used to migrate data from any supported remote storage system or LUN type to CLARiiON thin LUNs. In

other cases, like remote SAN Copy push sessions or remote incremental SAN Copy initial

synchronizations, the thin LUN will become fully consumed. For incremental SAN Copy, it may be

 possible to avoid the initial synchronization for new LUNs by selecting using the no initial sync required

option. Users must be certain that no writes have ever occurred to the source LUN if the No initial sync

option is used.

Table 5 and Table 6 describe the result of various SAN Copy scenarios to a thin LUN destination.

Table 5. Remote SAN Copy session summary to a thin LUN destinationCopy Direction Source Destination Result

Push

Thick or RAID group LUN R29,R30 thin Full

R29, R30 thin LUN R29,R30 thin Thin

Thin, thick, RAID group LUN Third-party thin Full

Thin, thick, or RAID group R28.5 thin LUN Full

PullThick, RAID group, third-party LUN R30 thin LUN Thin

Thick, RAID group, third-party LUN R29 thin LUN Full

Table 6. Local SAN Copy session summary to a thin LUN destination

Release Source Destination ResultR30 Thick or RAID group LUN Thin LUN Thin

R29 RAID group LUN Thin LUN Full

R29 or later Thin LUN Thin LUN Thin

MetaLUNsMetaLUNs have two capacity attributes: total  capacity and user  capacity. Total capacity is the maximum

capacity of the metaLUN in its current configuration. Additional capacity can be added to a metaLUN to

increase its total capacity. User capacity is the amount of the total capacity that is presented to the server.

Page 28: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 28/40

 

EMC SAN Copy

A Detailed Review 28

Users have control of how much of the total capacity is presented to the server as user capacity. When the

total capacity is increased, user capacity can also be increased. SAN Copy looks at user capacity to

determine which LUNs can be a source/target pair in a SAN Copy session.

LUN shrink and LUN expansionLUN shrink and LUN expansion operations are supported on all LUN types. LUN shrink is available for

Windows 2008 servers and requires Solutions Enabler to coordinate file system activities with the

reduction in capacity. LUN expansion is performed via metaLUNs for RAID-group-based LUNs. In release

30, pool-based LUNs can be expanded ―on the fly.‖ Any increase in pool LUN capacity is available almost

instantaneously. For thick LUNs, expansion only involves assigning additional 1 GB slices to the LUN. For

thin LUN expansion, the CLARiiON simply increases the LUN’s user capacity while consumed capacity is

unaffected by the operation.

When expanding a LUN that is using MirrorView, SnapView, or SAN Copy, user capacity cannot be

increased until the replication software is removed from the LUN. Since metaLUNs allow separate control

of total capacity and user capacity, the total capacity can be increased while the replica is in place,

For example, assume that a user wants to stripe-expand a LUN using metaLUNs. When a LUN is stripe-

expanded, data is restriped over added disks before the additional user capacity is available. You can

minimize the time the LUN is not being mirrored by allowing the striping operation to complete before 

removing the mirror from the LUN to increase user capacity. Increasing metaLUN user capacity is a nearly

instantaneous process.

Once user capacity is increased, the replica can be re-created on the LUN. To use the same destination

LUN, user capacity has to be increased to the same or greater user capacity than the source LUN.

For incremental SAN Copy, if I/O continues while the SAN Copy session is removed, a full

synchronization is required when the SAN Copy session is re-created. A full synchronization can be

avoided if I/O can be quiesced while the session is removed and user capacity is increased. The following

steps are recommended to avoid a full synchronization.

1.  Quiesce I/O and remove either the host or LUNs from the storage group. You must make sure that

there is no I/O or discovery of the new capacity while there is no session in place.

2.  Start the incremental SAN copy session after I/O is quiesced.

3.  Destroy the session.

4.  Increase user capacity of the source and destination LUNs.

5.  Re-create the session and clear the Initial Sync Required option. 

6.  Add hosts or LUNs back into the storage group for discovery of new capacity and resume I/O. 

For more information on LUN expansion with metaLUNs, see the white paper  EMC CLARiiON

 MetaLUNs - A Detailed Review on EMC.com and Powerlink. 

LUN MigrationLUN Migration can be used with SAN Copy images under certain conditions. LUN Migration is supported

to and from any LUN type; therefore, if requirements are met, it is possible to leave existing SAN Copy

sessions in place during the migration. The next table outlines the conditions under which SAN Copy

LUNs can and cannot be migrated. For more information on LUN Migration, see the Navisphere Manager

Help on Powerlink. 

Page 29: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 29/40

 

EMC SAN Copy

A Detailed Review 29

Table 7. LUN Migration rules for SAN Copy

LUN type Migrate to same size LUN Migrate to larger LUN

Source LUN on SAN Copy CLARiiON (push) Can be migrated*  Destroy session before

migration

Destination LUN on remote CLARiiON (push) Can be migrated*  No restriction

Destination LUN on SAN Copy CLARiiON

(pull)

Can be migrated Destroy session before

migration

Source LUN on remote CLARiiON (pull) Can be migrated No restriction

Reserved LUN (incremental SAN Copy) Cannot be migrated

* A session cannot be created on a LUN that is migrating.

SAN Copy and SnapView

SnapView and SAN Copy can operate on the same source and destination LUNs. SAN Copy can also useSnapView replicas as source LUNs in most cases. This allows for several configurations, including:

Maintaining a local replica of a source LUN with a SnapView snapshot or clone while maintaining a

remote replica of the same LUN on another storage system with SAN Copy.

Maintaining a local replica of a source LUN with a SnapView clone while using the clone as a source

for a SAN Copy session.

The clone must be fractured during the SAN Copy transfer.

Accessing the destination LUN via a SnapView snapshot or clone. The section ―Considerations for

mounting the destination LUN‖ provides more information.

SAN Copy and MirrorViewIncremental SAN Copy may be used to make copies of MirrorView mirrors. This provides an option for the

creation of local or remote full binary copies of mirrors. SnapView clones can also be used to make local

full binary copies of mirror images.

Val id SAN Copy source LUNs

SAN Copy can copy data from sources involved in other replication relationships. To avoid having to

quiesce the source LUN for the duration of the transfer, SnapView snapshots, SnapView clones, and

Symmetrix BCVs can be used as sources for full SAN Copy sessions. The data at the SAN Copy

destination will be consistent with the last time the replica was fractured. The next table outlines the LUN

types that may be used as a source.

Page 30: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 30/40

 

EMC SAN Copy

A Detailed Review 30

Table 8. Valid SAN Copy source LUNs

LUN type Valid source for a full SAN

Copy session?

Valid source for an incremental

SAN Copy session?

LUN, metaLUN, thick, or thinLUNnot in use with any replication

software. (Release 29 required forthin LUNs. Release 30 required forthick LUNs)

Yes

(Caution –  source LUN should notchange during the copy)

Yes

SnapView snapshot Yes No

(Incremental sessions use snapshots

internally)

SnapView clone Yes

(Caution –  source clone should not

change during the copy)

Yes

MirrorView source LUN Yes

(Caution –  source LUN should notchange during the copy)

Yes

MirrorView destination LUN No(A snapshot of the LUN may be usedas a SAN Copy source)

Yes

Symmetrix TimeFinder ® BCV Yes

(Caution –  source should not changeduring the copy)

 No

Symmetrix TimeFinder Snap Yes

(Caution –  source should not changeduring the copy)

 No

If MirrorView (meaning MirrorView/Synchronous and/or MirrorView/Asynchronous) is installed on the

storage system, then SAN Copy cannot use the MirrorView port12. However, if MirrorView is not installed

on the storage system, then SAN Copy can use all of the ports.

SAN Copy performanceThe following information provides a general overview of various performance considerations when using

SAN Copy. For details around performance expectations for a specific environment, users should engage

their account team and designated CLARiiON CSpeed representative, so that all relevant aspects of the

environment are factored in as appropriate.

Test conf igurat ion

The performance results were obtained using Fibre Channel interconnected CLARiiON CX3-80 systems

running FLARE 26 with no distance between two arrays. The following are true unless otherwise noted:

All graphs indicate the performance of a single SP pair (one source, one destination).For tests that utilized write cache, cache utilization stayed under the high-water mark.

For the full session and the initial incremental synchronization session tests, SAN Copy I/O was the

only I/O performed on the CLARiiONs during the tests.

12 The highest number FC/iSCSI port at initialization for CX4 series systems is as follows: Port 1 on CX3-

40, CX3-20, CX400/500; port 3 on CX-80 and CX600/700; FC MV port 5 on CX3-40c and CX3-20c;

iSCSI MV port 3 on CX3-40c and CX3-20c; FC MV port 3 on CX3-10c; iSCSI MV port 1 on CX3-10c;

FC MV port 1 on AX4-5 and AX4-5F8

Page 31: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 31/40

 

EMC SAN Copy

A Detailed Review 31

Ful l session push per formance over Fibre Channel

Figure 10 shows the general performance profile for full SAN Copy sessions and incremental SAN Copy

sessions using bulk copy (-copywholeLUN – nomark). Each concurrent session represents a SAN Copy

session push with one source LUN and one destination LUN. The upper curve represents performance

when the throttle is set to 10. The maximum throughput is reached after only a few sessions. When the

session throttle is set to 10, the top-line throughput scales with each model, where the CX4-960 has the

highest throughput and the CX4-120 has the lowest. The lower curve shows the performance with a throttlevalue of 6 (the default). At a throttle of 6, performance scales linearly as more simultaneous sessions are

run. Throttling is achieved by inserting delays between I/O. The performance across all CX3 series and

CX4 series systems is the same at the default throttle setting of 6.

Figure 10. SAN Copy Fibre Channel full session push performance versus the number ofconcurrent one-source LUN to one-destination LUN copy sessions

Total CLARiiON throughput can be increased by performing SAN Copy sessions on both SPs (SPA and

SPB) simultaneously, where each source SP is connected to a separate destination SP.

Incr emental session update perform ance over Fibre Channel

Figure 11 shows the update performance of incremental SAN Copy over Fibre Channel for two different

I/O profiles. The first profile consisted of random 4 KB I/Os that generated approximately 8 GB ofchanged blocks. The second profile used random 8 KB I/Os and generated approximately 16 GB of

changed blocks. SAN Copy coalesces changes that occur in contiguous 2 KB areas into I/O sizes of up to

64 KB. For the two curves shown in Figure 11, 90 percent to 95 percent of the I/Os written to the

destination LUN were 4 KB and 8 KB, respectively, indicating that there was not much coalescing. The

update bandwidth scales linearly with the I/O size. The updates were performed with no host activity on the

source LUNs, the bandwidth throttle value set at 10, the latency control values set to their defaults, and

write cache enabled at the destination.

10

Multiple Source->Target Pairs

1 Storage Processor  

1  2  3  4  5  6 Number of Sessions

MBs/Sec

Throttle 10

Throttle6

Page 32: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 32/40

 

EMC SAN Copy

A Detailed Review 32

Figure 11. SAN Copy incremental multiple session update performance over Fibre Channel

Transfer bandwidth is a complex function of a large number of parameters, including the success in

coalescing the source updates into larger contiguous I/Os for transfer, the channel bandwidth between the

storage systems and the switches, the rate at which the source system can fill the channel, the

compressibility of the data to be transferred, the ability of the switches to perform compression and write

acceleration, the bandwidth and delay on the line between the switches, and the rate at which the

destination can absorb the updates.

Page 33: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 33/40

 

EMC SAN Copy

A Detailed Review 33

ConclusionEMC SAN Copy software performs data consolidation and data distribution, and disaster recovery with

Replication Manager. SAN Copy copies data between CLARiiON storage systems, within CLARiiON

storage systems, between CLARiiON and Symmetrix storage systems, and between CLARiiON and

qualified non-EMC storage systems. SAN Copy can copy data directly from a source LUN on one storage

system to a destination LUN on another storage system without using host resources. SAN Copy can also

 perform multiple copy operations simultaneously.

You can use SAN Copy to create full or incremental copies of a source LUN. An incremental copy session

copies only the data that has changed since the last copy session. This can significantly reduce the time

needed to copy the data, thereby allowing the copy operation to be performed more frequently and more

effectively. Unlike full-copy sessions, the source LUN for an incremental session can remain online during

the copy process (which means that a host application can continue to send I/O to that source LUN).

ReferencesThe following titles can be found on Powerlink: 

 Navisphere Manager Online Help MirrorView Knowledgebook: FLARE 30 white paper

 Introducing EMC Unisphere: A Common Midrange Element Manager  white paper

 EMC CLARiiON Storage System Fundamentals for Performance and Availability  –  Applied Best

 Practices (This paper provides general guidelines and best practices for optimizing CLARiiON

 performance.) 

E-Lab Navigator (also at EMC.com)

Page 34: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 34/40

 

EMC SAN Copy

A Detailed Review 34

Appendix A: Symmetrix-to-CLARiiON migration guidePrior to performing the migration, ensure that the necessary software is in place. The CLARiiON storage

system will need to be accessible for management: via the Navisphere GUI or CLI. SAN Copy must be

enabled on the CLARiiON storage system. The Symmetrix system must be accessible for management via

either ESN Manager or EMC Ionix™  ControlCenter ®

 SAN Manager ™. Optionally, Navisphere Host

Agent may be installed on a host connected to the Symmetrix system to obtain volume information.

Zoning

Identify the CLARiiON SP port(s) and Symmetrix front adapter (FA) port(s) you will use for SAN Copy

data transfer. Create a zone between each CLARiiON SP port and Symmetrix FA port. This can be done

using ESN Manager or EMC ControlCenter SAN Manager; or it may be done directly from the switch

management console. Figure 12 shows the zone between an FC4700 port and a Symmetrix FA port.

Figure 12. Zone between a CLARiiON system and a Symmetrix FA port

Establ ishing p or t con nect iv i ty

Once the zones have been created, use either the Navisphere GUI or CLI to perform an update connections

operation. This will force the CLARiiON SP ports to log in to the FA ports. To verify that the CLARiiON

SP ports are logging in successfully to the Symmetrix FA, check the login history table on the Symmetrixsystem. This is accomplished with ESN Manager/EMC ControlCenter SAN Manager on a per-FA port

 basis. Select the FA port, right-click, and select Properties. One of the properties is called logins.

Symmetr ix volume access

Identify the Symmetrix volumes that are the source or destination for SAN Copy data transfer. This may be

a standard volume, BCV, or a metavolume. Use either ESN Manager or EMC ControlCenter SAN Manager

to give the connected host and CLARiiON SP ports access to destination volumes. When the Symmetrix

Page 35: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 35/40

 

EMC SAN Copy

A Detailed Review 35

system assigns access for a volume to a CLARiiON SP port, it is no different than assigning access to a

regular host connected by means of a fabric. Figure 13 illustrates how the volume access is granted to a

Symmetrix volume.

Figure 13. ESN Manager adds access to a Symmetrix volume

Obtain ing Symmetr ix volume informat ion

Symmetrix volume information may be obtained by one of two methods. In order to have Symmetrix

volume information displayed in the Navisphere SAN Copy Wizard, Navisphere Host Agent must be

installed on a host connected to the Symmetrix system and configured as a Navisphere portal.

Alternatively, the Symmetrix volume WWN may be retrieved by using the symdev command and entered

directly into the SAN Copy session.

Portals are a functionality that allows for the management of out-of-band objects within Unisphere or

 Navisphere Manager. If the Symmetrix-connected host is also connected to the CLARiiON system and is a

managed host, there is no need to add it via portal. But if the Symmetrix-connected host is only connected

to the Symmetrix system, then the host needs to be made part of the Unisphere/Navisphere domain using a

 portal. Portals are also used to bring hosts into the domain for event monitoring purposes. As such, the

functionality for portals is found in the Event Notification section of Unisphere.  Figure 14 shows where

 portals are managed in Unisphere and Navisphere Manager.

Page 36: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 36/40

 

EMC SAN Copy

A Detailed Review 36

Figure 14. Configuring a portal in Unisphere and Navisphere Manager

Figure 15. Host shown as part of a portal running on a CLARiiON system

As shown in Figure 15, a host directly connected to the Symmetrix storage system (in this case, L82at162)

is added to a portal running on a CX400 storage system: SANCOPY_CX400-1. Note that the Portal

Configuration dialog in Navisphere is called the Configure Centralized Monitor dialog in Unisphere as seen

in Figure 14. 

Page 37: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 37/40

 

EMC SAN Copy

A Detailed Review 37

As an alternative to configuring a portal, the symdev command gives the necessary output to determine

volume WWNs. The volume WWN will have to be entered into the SAN Copy session as source or

destination storage.

$>symdev -sid  SymmID  -wwn 

Symmetrix ID: 000184700643

Device Name Device

---------------------------- ---------------------------------

Sym Physical WWN

---------------------------- ---------------------------------

0000 \\.\PHYSICALDRIVE3 6006048000018470064356434D303030

0001 Not Visible 60060480000184700643464241303031

0002 Not Visible 60060480000184700643464241303032

The Symmetrix volume number is on the left, followed by the host's name for the device, if any, and then

the WWN.

Creat ing a SAN Copy s ession

The SAN Copy Create Session Wizard can be used to create a SAN Copy session between a CLARiiON

and Symmetrix system. To access the Symmetrix volume from the Storage Source list , select the host

system that is connected to the Symmetrix system. As shown in Figure 16, host L82at162 is selected from

the list. After the host is selected as a storage source, all the volumes that are presented to this host by the

Symmetrix system are visible. These volumes can be selected as either the source or destination for the

SAN Copy session.

Figure 16. Symmetrix volume as seen from Navisphere

Page 38: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 38/40

 

EMC SAN Copy

A Detailed Review 38

Figure 17 shows an example of a SAN Copy session that has a source on a Symmetrix storage system and a

destination on a CX400 (SANCOPY_CX400-1).

Figure 17. SAN Copy session property sheet

In addition to choosing the Symmetrix storage device in Navisphere, the WWN of the device can be

entered directly. To discover the volume WWN, use the symdev command, as instructed in the previous

section. Then, enter the device WWN using the Enter WWN   button in the dialog box to select source or

destination storage.

Page 39: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 39/40

 

EMC SAN Copy

A Detailed Review 39

Running the SAN Copy s ession

Once the session is created, it can be started from within Unisphere/Navisphere or using NaviSecCLI.

Figure 18 illustrates how the SAN Copy session is started from within Unisphere and Navisphere Manager.

Figure 18. Starting the SAN Copy session

To start the SAN Copy session, simply click the Start button in Unisphere or right-click the session in

 Navisphere. Percent Complete is shown in the session table in Unisphere. Users can refresh the table toupdate status. To check the progress of the SAN Copy session through Navisphere, right-click the session

and select Status. 

Page 40: h2099 Emc Clariion San Copy Wp

8/13/2019 h2099 Emc Clariion San Copy Wp

http://slidepdf.com/reader/full/h2099-emc-clariion-san-copy-wp 40/40

 

Appendix B: SAN Copy/E for CX300 and AX100/150SAN Copy/E is a modified version of the SAN Copy application that runs only on a CX300 or an

AX100/150. SAN Copy/E was developed to extend the core-to-edge replication options. Before SAN

Copy/E, SAN Copy allowed data to be incrementally copied to a CX300 or AX100/150, but it could only

 perform full transfers from the CX300 or AX100/150 by a SAN Copy hosting system; SAN Copy/E allows

data to be incrementally copied from a CX300 or AX100/150 system. As with SAN Copy, SAN Copy/E

can be used over IP, provided that EMC-supported distance extenders (FC to IP switches) are used.

SAN Copy/E is designed to perform incremental pushes to a CX400 or above storage system with SAN

Copy installed. Therefore, with SAN Copy/E, the following operations are not supported: 

Copying between a CX300 and an AX100/150

Copying between two CX300s, or between two AX100/150s

Intra-storage-system copies within CX300s or AX100/150

Copying to third-party storage systems

SAN Copy/E management

The Navisphere Manager GUI and CLI provide the same look and feel for SAN Copy/E as for SAN Copy.This means that Navisphere Manager must be installed on an AX100/150 to use SAN Copy/E. Like SAN

Copy, the user can launch the SAN Copy/E Wizard by right-clicking the storage system and selecting SAN

Copy > Create Session. Alternatively, the user can create a SAN Copy session by right-clicking on the

LUN and selecting SAN Copy > Create Session from the LUN.

SAN Copy/E sys tem l imi ts

Table 9 provides the limits associated with SAN Copy/E.

Table 9. SAN Copy/E storage system limits

Storage system CX300 AX150,

AX100

Sessions per Storage System (full or incremental)

Defined sessions 300 100

Running sessions (split over two SPs, if present) 4 2

Destination LUNs

Per source 50 50

Incremental Sessions

Per storage system 25 10

Per source LUN 8 1

On the CX300, the SAN Copy incremental session limits are shared with SnapView; on the AX100/150, they are

not. For instance, if a LUN on a CX300 already has eight SnapView sessions running on it, an incremental SAN

Copy/E session cannot be created on the same source LUN until the user stops at least one SnapView session.Alternatively, on an AX100/150, a user may have an existing SnapView session, as well as an incremental SAN

Copy/E session.