110-112 ADDISON ROAD = 1492.8 m² BY SURVEY
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
G
26/06/2017 10:19:09 AM
110-112 ADDISON ROADMARRICKVILLE
S96-000 KAA1510
COVER PAGE & GENERAL NOTES
SECTION 96
GENERAL NOTESThe copyright of this design remains the property of AN+A. Thisdesign is not to be used, copied, or reproduced without the authorityof AN+A. Do not scale from drawings. Confirm dimensions on siteprior to the commencement of works. Where a discrepancy arisesseek direction prior to proceeding with the works. This drawing is onlyto be used by the stated Client in the stated location for the purpose itwas created. Do not use this drawing for construction unlessdesignated.
COORDINATIONWhere applicable refer to and coordinate information contained in thearchitectural drawings, and the documentation of other consultants.Notify discrepancies between architectural and/or other consultant’sdocumentation for direction prior to proceeding with the affected partof the works.
SPECIFICATIONS AND SCHEDULESWhere applicable refer to and coordinate with relevant specificationsand schedules. Written specifications and schedules take precedenceto the extent of any discrepancy. Notify discrepancies betweendocuments for direction prior to proceeding with the affected part ofthe works.
DETAIL DRAWINGSUnless noted otherwise, refer to detail drawings for set-outinformation. Drawings at larger scales take precedence over drawingsat smaller scales to the extent of any discrepancy. Notify discrepanciesfor direction prior to proceeding with the affected part of the works
EXECUTIVE OF THE WORKS (STANDARD)Execute the works in compliance with the current edition of theBuilding Code of Australia (as amended), current editions of relevantAustralian and other applicable published Standards and the relevantrequirements of Local and Statutory Authorities.
UNITS OF MEASUREMENTUnless otherwise noted:-Dimensions are shown in millimetres; and-Levels are shown in metres
TO DETAILWhere a notation refers to an item as “…to detail” the applicable item isto be in accordance with the relevant Architect’s detail.
MATERIALS HANDLING AND STORAGEUnless noted otherwise material, fixtures and fittings are to behandled, stored and installed in accordance with the Manufacturer’scurrent written instructions.
The building is to be constructed in accordance with the National Construction Code of Australia (NCC 2016) andall relevant Australian Standards and with particular regard to the following:
1. Structure is to comply with NCC 2016 Part B1.2. Masonry construction is to comply with NCC 2016 AS 3700 – 2011.3. Steel structures are to comply with clause AS 4100 – 19984. Composite steel and concrete is to comply with AS 2327.1-2003.5. Aluminium construction is to comply with AS/NZS 1664.1-1997 Amdt 1: 1999 or AS/NZS 1664.2-1997 Amdt1:19996. Timber construction is to comply with clause AS 1720.1 – 2010 Amdt 1 & 2, & AS 1684.2 – 2013 Amdt 1, AS1684.3 – 2010 Amdt 1 or AS 1684.4 – 2010 Amdt 1.7. Glazing assemblies are to comply with NCC 2016 clause B1.4 & F1.13, AS 2047-2014 and AS 1288-2006Amdt 1 & 2.8. Termite risk management is to comply with NCC 2016 clause B1.4 & AS 3660.1 – 2014.9. Metal roofing is to comply with AS 1562.1 – 1992 Amdt 1, 2 & 3.10. Lift shafts which are not required to have an FRL are to comply with NCC 2016 clause B1.4 (m).11. Lightweight construction is to comply with NCC 2016 clause C1.8 and Spec C1.8.12. Fire hazard properties of linings, materials and assemblies are to comply with NCC 2016 Clause C1.10 andSpec C1.10.13. Enclosure of shafts is to comply with NCC 2016 Spec C2.10.14. Building elements required to have an FRL shall be designed to comply with NCC 2016 Specification C1.1 asapplicable to Type B C construction and Spec A2.3.15. Flooring and floor framing of lift pits must be non-combustible. (Type A & B)16. Roof lights are designed in accordance with NCC 2016 Spec C1.1 Clause 3.6.17. Fire separation of main switchboard that sustains emergency equipment, in accordance with NCC 2016 ClauseC2.13.18. Fire doors must comply with NCC 2016 Spec C3.4 and AS/NZS 1905.1 – 2015.19. Openings in shafts protected in accordance with NCC 2016 Clause C3.13. Service penetrations in fire ratedconstruction are to be protected in accordance with NCC 2016 C3.12, C3.15 & Spec C3.15, AS1530.4-2014 & AS4072.1-2005 (R2016)20. Openings for services that penetrate a building element that is required to have an FRL in respect to integrityor insulation or a resistance to the incipient spread of fire shall be protected in accordance with NCC 2016 clauseC3.15.21. Installation in exits and paths of travel are to comply with NCC 2016 Clause D2.7 – All telecommunication andelectrical cupboards are to be installed with non-combustible backings on the doorway and smoke seals installedto all door leaves. All services which penetrate the cupboard have been smoke sealed to prevent the free passageof smoke.22. Cupboards or storerooms below non-fire isolated stairs are to be enclosed in fire rated construction inaccordance with NCC 2016 Clause C2.8.23. Pedestrian ramps are to comply with NCC 2016 D2.9 and where serving as an accessible ramp, must complywith AS1428.1-2009 Amdt 1 2010.24. The floor surface of ramps, treads/nosings of stairways and landings are to have a slip resistance classificationnot less than that listed in NCC 2016 Table D2.14.25. All going & risers of stairways are to comply with NCC 2016 Clause D2.13.26. All landings to comply with NCC 2016 Clause D2.14.27. Restriction on placement of steps or ramps at door thresholds to be in accordance with NCC 2016 ClauseD2.15. Thresholds steps where permitted are to be no greater than 190mm in accordance with Clause D2.15 (nogreater than 50 mm in Class 9b entertainment venue).28. Balustrades are to be provided and shall comply with NCC 2016 Clause D2.16.29. Handrails are to be provided where required and shall comply with NCC 2016 Clause D2.17 Clause 12 ofAS1429.1-2009 Amdt 1.30. Doorways and doors are to comply with NCC 2016 Clause D2.19 and D2.20.31. Operation of door latches is to comply with NCC 2016 Clause D2.21.32. Access for people with disabilities is to comply with NCC 2016 clauses D3.1, D3.2, D3.3, D3.5 carparking D3.6signage, D3.7 hearing, D3.8 Tactiles , D3.9 seating, D3.10 Swimming pools. D3.11 ramps and D3.12 glazing andAS 1428.1 – 2009 Amdt 1.33. Signage for people with disabilities in accordance with BCA 2014 D3.6, Spec D3.6 and AS1428.1-2009 Amdt 134. Tactile indicators to be provided in accordance with BCA 2014 Clause D3.8 and AS/NZS 1428.4.1-2009 Amdt1.35. Marking of glazing in accordance with BCA 2014 D3.12, and AS 1428.1- 2009 Amdt 2 2014.36. Existing fire hydrants to provide coverage to the new layout in accordance with NCC 2016 Clause E1.3 and AS2419.1 – 2005 Amdt 1 2007.37. Existing fire hose reels to provide coverage to the new layout in accordance with NCC 2016 E1.4 and AS2441-2005 Amdt 1 2009. Fire hose reels to be located within 4m of the exit.38. Existing sprinklers to be modified to suite new layout in accordance with current fire safety schedule.39. Portable fire extinguishers to comply with NCC 2016 Clause E1.6 and AS 2444-2001.40. Miscellaneous air-handling systems covered by Sections 5 (miscellaneous) and 11(Kitchen hood exhaust ) ofAS/NZS 1668.1 2015 serving more than one fire compartment (other than a carpark ventilation system) and notforming part of a smoke hazard management system must comply with that Section of the Standard.41. Passenger lifts are to comply with NCC 2016 Clauses E3.1, Specification E1.3 E3.6, Table E3.6a, Table E3.6b,E3.7, E3.8, E3.9, E.10 & AS1735. AS 1735.11-1986 & AS 1735.1-2016.42. Signs warning against use of lifts are to comply with NCC 2016 Clause E3.3.43. All applicable fire services to be altered to suit new layout in accordance with appropriate AustralianStandards.44. Emergency lighting is to comply with NCC 2016 Clause E4.2, E4.3, E4.4 and AS 2293.1-2005 Amdt 1 2008.45. Exit signs are to comply with NCC 2016 Clause E4.5, E4.6, E4.8 and AS 2293.1-2005 Amdt 1 2008.46. Stormwater drainage is to comply with AS/NZS 3500.3 -2015.47. Building elements in wet areas must be water-resistant or waterproof, as required, in accordance with clauseNCC 2016 F1.7 and AS 3740 – 2010 Amdt 1 2012.48. Damp proofing & damp proof course shall comply with NCC 2016 F1.9 & AS/NZS 2904-1995 Amdt 1 & 2 (DPC)or AS 3660.1-2014.49. Floors on ground shall prevent moisture rising by the insertion of a vapour barrier in accordance with NCC2016 Clause F1.10 & AS 2870-2011.50. Sanitary and other facilities are to be provided in accordance with NCC 2016 F2.1 and F2.3, as relevant.51. The accessible sanitary facility and ambulant facilities for people with disabilities shall be constructed to complywith AS1428.1-2009 and NCC 2016 Clause F2.4.52. Construction of sanitary facilities is to be in accordance with NCC 2016 Clause F2.5.53. Sanitary compartments doors must be removable from the outside unless there is a clear space of 1.2m inaccordance with NCC 2016 clause F2.5.54. Artificial lighting & power is to be in accordance with NCC 2016 Clause F4.4, J6.2, J6.3, J6.4, J6.5 & J6.6 &AS/NZS 1680.1-2006.55. Mechanical ventilation is to be in accordance with NCC 2016 Clause F4.7, F4.9 J3.5 & J3.7 (evaporativecoolers), J5.2, J5.3, J5.4 & J5.5 & AS 1668.2 - 201256. Walls (Building fabric & building sealing energy efficiency) – NCC 2016 Clause J1.5 & J3.657. Glazing (Energy Efficiency measures) – NCC 2016 Clause J2.1 and J2.4 and U-Values and SHGC of glazing tosupport a completed glazing calculator58. Hot water supply (Energy Efficiency) – NCC 2016 Clause J7.2 & Part B2 of NCC Volume 3 – Plumbing Code ofAustralia59. Access for maintenance (Energy Efficiency) – NCC 2016 Clause J8.360. Wall ties to comply with AS3700-2011 & AS2699.1-2000 based on distance of the structure from the coast andwhether that coast opens to a shelthered bay or clear ocean61. Adaptable housing units shall comply with AS4299-1995.
SECTION 96110-112 ADDISON ROAD, MARRICKVILLE
STRUCTURE Foundations, footings, reinforced concrete, slabs, retainingwalls, framing, bracing, tie-down and other structural elementsare to be designed and constructed in accordance with theStructural Engineer’s details and specifications.
HYDRAULICSStormwater drainage, waste water drainage, fresh water, gassupply and other hydraulic services are to be designed andconstructed in accordance with the Local Authority, StatutoryAuthority, Hydraulic and/or Civil Works Consultant’srequirements.
EROSION & SEDIMENT CONTROLApply erosion and sediment control measures in accordancewith the Local Authority and, where applicable, Hydraulic or CivilWorks Consultant’s requirements to avoid erosion,sedimentation and/or contamination of the site, surrounds andstormwater drainage system. Apply measures to ensure that thesite remains free of water and to prevent water flow over the newwork. Erosion & sediment control measures are to be effectivefrom commencement of the works (including demolition) andmaintained throughout the course of the works until the site isfully stabilised.
SERVICES (EXISTING & PROPOSED)Confirm location of existing under and above-ground servicesand coordinate with the relevant service authority to ensure thatservices are handled in accordance with the relevant authoritiesinstructions prior to commencement of demolition, excavationand/or construction works.
LEVELSLevels shown are consistent with the datum and benchmarksshown on the associated detail survey. In most instances thesurveyed levels will be indicated relative to Australian HeightDatum. However the existing site levels and datum are to beconfirmed on site with the reference to the site surveydocuments.
FALLSFinish surfaces typically to fall as required to facilitate effectivedrainage.
INTERPRETATION“Provide” means to supply and install.“Required” means required by the contract documents or by theLocal or Statutory Authorities.“Proprietary” means identifiable by naming the manufacturer,supplier, installer, trade name, brand name, and catalogue orreference number.
scale - N.T.S.LOCATION PLAN1
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 07.03.17 CONSULTANT COORDINATION AC 17.03.17 DRAFT CCD 13.04.17 DRAFT S96 ISSUEE 27.04.17 QS ISSUEF 15.05.17 QS ISSUEG 16.05.17 S96 ISSUE
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
G
26/06/2017 10:19:23 AM
110-112 ADDISON ROADMARRICKVILLE
S96-002 KAA1510
VIEW 01 - ADDISON ROADPERSPECTIVE
SECTION 96
V1 ADDISON ROAD PERSPECTIVE1
12PM WINTER SOLSTICE
01. HERRING BONE BRICKPAVING AROUND EXISTING
SANDSTONE CURBS
08. VERTICAL BORDEREDOFF-FORM CONCRETE
06. FAIR FACED CONCRETE
FINISHES SCHEDULE
4
16 13 13
8 17
12. SAFETY JALOUSIEGLASS LOUVRES
12
- VIEW FROM THE OPPOSITE BOUNDARYCIRCA 1:100 @ A3
13. RECYCLED BRICKS
14
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 17.03.17 DRAFT CCC 13.04.17 DRAFT S96 ISSUED 20.04.17 CONSULTANT COORDINATION DE 27.04.17 QS ISSUEF 15.05.17 QS ISSUEG 16.05.17 S96 ISSUE
15. TILES 16 AUSTRAL PLYWOOD
17. BLADE SUN SHADE
15
15 15
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
G
26/06/2017 10:28:42 AM
110-112 ADDISON ROADMARRICKVILLE
S96-003 KAA1510
VIEW 02 - ILLAWARRA ROADPERSPECTIVE
SECTION 96
V2 ILLAWARRA ROAD PERSPECTIVE1
8
15 13
8 1712
12PM WINTER SOLSTICE
- VIEW FROM THE OPPOSITE BOUNDARYCIRCA 1:100 @ A3
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 17.03.17 DRAFT CCC 13.04.17 DRAFT S96 ISSUED 20.04.17 CONSULTANT COORDINATION DE 27.04.17 QS ISSUEF 15.05.17 QS ISSUEG 16.05.17 S96 ISSUE
01. HERRING BONE BRICKPAVING AROUND EXISTING
SANDSTONE CURBS
08. VERTICAL BORDEREDOFF-FORM CONCRETE
06. FAIR FACED CONCRETE
FINISHES SCHEDULE
12. SAFETY JALOUSIEGLASS LOUVRES
13. RECYCLED BRICKS
15. TILES 16 AUSTRAL PLYWOOD
17. BLADE SUN SHADE
17
16
AS96-160
AS96-160
H
H
G
G
F
F
C
C
B
B
A
A
01 01
02 02
03 03
04 04
05 05
07 07
08 08
06 06
4565 8185 2450 6565 3560 3810 5745 50
E
E
4680
5400
4500
2450
8650
4180
4530
4970
5525
60010 10
LIFT B
LIFT AEXISTINGBUILDING ABOVE
09 09
D
D
1:8 RAMP 1:4 RAMP
300
3320
300
SHAR
EDZO
NESTAIR ABOVE2450 F/C UNDERSIDECLEARANCE
STOR
AGE
KERB ABOVE
TRAFFICCONTROL BOX
TELSTRA PIT
TRAFFICCONTROL BOX
SV SV
TELSTRAPIT
GRATED PITEKI INLET
TELSTRAPIT
GAS
HYD
TRAFFIC LIGHT
TRAFFIC LIGHT STOR
AGE
1
2
4
5
3
11
6
7
8
9
21
20
18
22
25
24
26
27
28
30
STOR
AGE
LANDSCAPE ABOVE
BS96-161
BS96-161
23
CS96-162
CS96-162
31
33
34
+RL 6.78
STOR
AGE
STOR
AGE
STOR
AGE
DEEP SOIL
STOR
AGE
KERB ABOVE ATGROUND LEVEL
TREE LOCATION AT GROUND LEVEL
TREE LOCATION ATGROUND LEVEL
TREE LOCATION AT GROUND LEVEL
STOR
AGE
EXISTINGBUILDING ABOVE
EXISTINGBUILDING ABOVE
TREE LOCATION AT GROUND LEVEL
GROUND FLOOR FOOTPRINTSHOWN DASHED
PLANT
FIRE STAIR 3
5800
TREE LOCATION AT GROUND LEVEL
TREE LOCATION AT GROUND LEVEL
32
HYDSVHYD
4680
5400
4500
150
100
2200
3300
100
5250
255
100
3825
1675
100
2755
4970
2525
250
2750
600
5800
12
FHR
SHAR
EDZO
NE
10
29
35
DS96-163
DS96-163
+RL 6.44
4425
3300
19
9805
FHR
ELECTRICAL MAIN SWITICH ROOM TOELECTRICAL ENGINEER'S DETAILS
PLANT
2400
+RL 6.78
R 10
000
STAIRLANDINGABOVE
ALL NEW FIRE ISOLATED STAIR TO HAVESINGLE HANDRAIL COMPLYING WITHAS1428.1-2009 & STAIR NOSINGS
ALL NEW FIRE ISOLATED STAIRTO HAVE SINGLE HANDRAILCOMPLYING WITH AS1428.1-2009& STAIR NOSINGS
1270
13 14 15 16 17
RAINWATER RE-USE TANK ABOVE23.23M³
1:20 DRIVEWAY RAMP 39805
MOTORCYCLE
FIRE HYDRANT PUMP (725mm x 2500mm)
DEEP SOIL
FH
FH
COLD WATERPUMP ROOM
4475
OSD TANK ABOVE 23M³
STOR
AGE
STORAGE
11
11
1200
+RL 6.44 +RL 6.00
+RL 6.00+R
L 6.78
DRIVEWAY RAMP 1
+RL 6.52
SIGNAL
SIGNAL
875
875
KERB
KERB CARPARKEXHAUST RISER
REFER TO DEFERRED COMMENCEMENTREPORT & THE STRUCTURAL ENGINEER'SLETTER FOR DETAILS ON THE EXISTING WALLABOVE IN REGARDS TO CONDITION PART A 3.
230
KERB
GARAGE DOOR
KERB
+RL 6
.56
SHAR
EDZO
NE
PLANTER TO ABOVE - NOT TOIMPEDE ACCESSIBLE CAR SPACE
BULKYHOUSEHOLD
STORAGE
MOTO
RCYC
LE
GREASEARRESTOR
SHAR
EDZO
NE
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BASE
MENT
SET
BACK
CAR
SPAC
ES
INTE
RNAL
WAL
LS
4680
490
2820
3136
555
2560
0
600
5400
125
2275
2700
2100
300
2700
2400
7200
5500
2400
2400
2400
1500
800
4680
GRIDLINES
STRUCTURAL COLUMNS
CAR SPACES/PLANT
INTERNAL WALLS
4680
5400
4500
2450
8650
4180
4530
4970
5525
600
4680
5400
4500
2450
8650
4180
4530
4970
5525
600
4488
060
0
4680
4970
1875
3650
600
4480
200
4800
600
1600
300
024
0020
060
018
5055
024
0080
048
0010
070
524
0010
7513
2580
024
005
2395
2575
125
2400
3000
600
4565 6565 3560 3810 5745
4565 24570 5745 50BASEMENT SETBACK/DEEP SOIL
4565 8185 2450 160 2400 2400 300 1310 1090 2400 65 2335 1200250
25 5745
CAGE AND DOUBLE GARAGEDOORS TO BAYS 22-27
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BASE
MENT
SET
BACK
CAR
SPAC
ES
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
CAR SPACES/LIFT A
INTERNAL WALLS
BASEMENT SETBACK/DEEP SOIL
50 4565 8185 2450 6565 3560 3810 5745225
50 34880
1160 3405 1995 5800 75 2525 5000 400 6160 805 4595 1150
5400
3305 2001060 1795 200 6065 125125 PLANT
2325 975 250 2035 200STORAGE
3305 200 6160 5400 1150FIRE STAIR
SWP
SWP
SWPSWP
SWP
BASEMENT PUMPOUT PIT TOHYDRAULIC ENGINEER'S DETAILS
STORMWATER PIT TO HYDRAULICENGINEER'S DETAILS
DP
DP
DP
DP
DP
DP
DP
DP
ELEC
TRIC
AL K
IOSK
SUBS
TATI
ON A
BOVE
1:20 D
RIVE
WAY
RAM
P 2
1400
0
1:40 D
RIVE
WAY
RAM
P 5
3200
FFL 6.78
+RL 6.70+RL 6.70
+RL 6.40
UP
UP
+RL 6.00
+RL 6.92
+RL 6.92 +RL 6.00
+RL 6.40
1:20 D
RIVE
WAY
RAM
P 4
6800
DETAILS OF BULK EXCAVATION, SHORING/PILECONSTRUCTION IN ACCORDANCE WITHSTRUCTURAL ENGINEER'S DETAILS
NOTE BOUNDARY AS PER SURVEY
GREASE ARRESTOR & PUMPINGSTATION. REFER TO HYDRAULICENGINEER'S DETAILS
4 WALL MOUNTED BICYCLE SPACES
MINIMUM 2500mm CLEARANCEHEIGHT OVER ACCESSIBLE ANDSHARED ZONE TO AS2890.6-2009
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
Q
26/06/2017 10:19:39 AM
110-112 ADDISON ROADMARRICKVILLE
S96-010 KAA1510
BASEMENT PLAN
SECTION 96
scale - 1 : 200@ A3BASEMENT1
NOTE:• MINIMUM 2200mm HEADROOM CLEARANCE TO
STRUCTURE AND SERVICES• MINIMUM 2500mm HEADROOM CLEARANCE FOR
ACCESSIBLE AND SHARED ZONE SPACES TOSTRUCTURE AND SERVICES
• MINIMUM 5500mm WIDE GARAGE DOOR TO ALLDOUBLE PRIVATE GARAGES
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 22.02.17 REVISED ACCESSD 24.02.17 DEFERRED COMMENCEMENT ISSUEE 13.03.17 STRUCTURAL REVIEWF 14.03.17 MECHANICAL ISSUEG 14.03.17 LANDSCAPE ISSUEH 17.03.17 DRAFT CCI 27.03.17 CONSULTANT COORDINATION BJ 28.03.17 CONSULTANT COORDINATION CK 10.04.17 ELEC. ISSUEL 11.04.17 MECH. ISSUEM 13.04.17 DRAFT S96 ISSUEN 20.04.17 CONSULTANT COORDINATION DO 27.04.17 QS ISSUEP 15.05.17 QS ISSUEQ 16.05.17 S96 ISSUE
S96-153
1
S96-152
1
S96-151
1
AS96-160
AS96-160
H
H
G
G
F
F
C
C
B
B
A
A
01 01
02 02
03 03
04 04
05 05
07 07
08 08
06 06
G.R04CAFE / RESTAURANT
LIFT B
G.C02COMMERCIAL
G.C03COMMERCIAL
G.C05COMMERCIAL
G.C06COMMERCIAL
G.C07COMMERCIAL
FIRESTAIR 2
4565 8185 2450 6565 3560 3810 5745
E
E
4680
5400
4500
2450
8650
4180
4530
4970
5525
10 10
COMMON CIRCULATION (EXT. VENT.)(89.06 m²)
COMMON CIRCULATION(12.12 m²)
09 09
D
D
1:14 R
AMP
1
G.C01COMMERCIAL
HYDSV
HYD
GRATED PITEKI INLET
LANDSCAPEAREA
POWERPOLE
LIFT A
+RL 9.92
36
BS96-161
BS96-161 1:4 RAMP
CS96-162
CS96-162
EX RL 9.00
FIRE STAIR 3
1:8 RAMP
LEVEL 1 ABOVE SHOWN DASHED
H A N D L E Y L A N E
SHAREDZONE
KIOS
KSU
BSTA
TION
DEEP SOIL
STAIR TOLEVEL 1
FIRESTAIR 1
FIRE EGRESS
+RL 9.70
+RL 9.14
+RL 9.70
2000
DS96-163
NATURAL GAS REGULOATOR INPLANTER TO HYDRAULIC'S DETAILS
G/H/
C
300
3320
300
+RL 10.15
ELEC
.CU
PBOA
RD
FIRE HYDRANT BOOSTER
RAINWATER RE-USE TANKBELOW 23.23M³
1:25 RAMP3600
LOCATIONFOR WC
LOCATIONFOR WC
LOCATIONFOR WC
5800
3300
1:20 WALKWAY REMOVABLE BOLARDS
1:14 RAMP 1
2500
GAS & COLD WATER METER
WASTESTORAGE
FH
FH
6000
(SID
E BO
UNDA
RY S
ETBA
CK)
FHR
FHR
FHR
FH
EXISTING TREE TO BE REMOVED
OSD TANK BELOW 23M³
COMMERCIALVISITOR
4 BICYCLE SPACES
6 WAL
L MOU
NTED
BICY
CLE
SPAC
ES
9.979.96
9.95
9.88
9.84
9.81
9.79
9.76
9.65
9.56
9.45
9.40
9.81
9.81
10.01
10.08
10.14
10.0810.05
10.04
9.91
9.85
10.00 10.00
9.939.98
9.73
9.71
9.63
8.898.68
9.81
9.76
9.819.87
9.859.85
9.88
9.999.98
9.97
9.91 9.93
9.83 9.90
9.82
9.41
8.508.738.84
8.93
8.90
8.55 8.54
8.45
9.48
TRAFFICCONTROL BOX
TELSTRA PIT
TRAFFICCONTROL BOX
SV SV
TELSTRAPIT
TRAFFIC LIGHT
TRAFFIC LIGHT
EKI INLET
TELSTRAPIT
GAS
EX RL 9.40
GRATED PIT
HYD
R 10000
HYDSV
HYD
I L L
A W
A R
R A
R
O A
D
A D D I S O N R O A D
BOUNDARY 3705m
m 74°10
'00"
BOUNDARY 33160mm 114°43'35"
BOUN
DARY
3933
0mm
33°3
5'55"
BOUNDARY 34920mm 303°41'35"
BOUN
DARY
2435
0mm
213°
56'30
"BO
UNDA
RY 91
450m
m 21
3°51
'20"
BOUN
DARY
1197
5mm
213°
55'20
"
1:14
1:14
LOADING
10 BINS
DEEP SOIL
1005
1025
1025
1025
1025
1060
INTERCOM SYSTEM TO BE INSTALLED INACCORDANCE WITH CONDITION 28
SIGNAGE
REFER DEFERRED COMMENCEMENT REPORT & THESTRUCTURAL ENGINEER'S LETTER FOR DETAILS ON THEEXISTING WALL IN REGARDS TO CONDITION PART A 3.
11
11
SIGNAGE TO ACCESSCONSULTANT'S DETAILSSIGNAGE TO ACCESS
CONSULTANT'S DETAILS
SIGNAGE TO ACCESSCONSULTANT'S DETAILS
900mm SETBACK FROM SITE BOUNDARYTO ACCESS REQUIREMENTS
SIGNAGE TO ACCESSCONSULTANT'S DETAILS
SIGNAGE TO ACCESSCONSULTANT'S DETAILS
DIRECTIONAL SIGNAGE TO ACCESSCONSULTANT'S DETAILS
DIRECTIONAL SIGNAGE TO ACCESSCONSULTANT'S DETAILS
SIGNAGE TO ACCESSCONSULTANT'S DETAILS
ACCESSIBLE ENTRY SIGN TOACCESS CONSULTANT'S DETAILS
AREA SHOWN HATCHED TO BE PAVINGTO ENSURE SUITABLE DEVIATION OFPEDESTRIAN ACCESSWAY FROMVEHICULAR ACCESS TO ACCESSCONSULTANT'S DETAILS
ACCESSIBLE ENTRY SIGN TOACCESS CONSULTANT'S DETAILS
ACCESSIBLE ENTRY SIGN TO ACCESSCONSULTANT'S DETAILS
INTERCOM SYSTEM TO BE INSTALLEDIN ACCORDANCE WITH CONDITION 28
BUILDING IDENTIFICATION NUMBER INACCORDANCE WITH CONDITION 59
EXISTING STONE KERB TO BE PRESERVEDACCORDING TO CONDITION 102
INFILL BALUSTRADE TO BE CLEAR GLAZINGACCORDING TO CONDITION PART A 3
BIN HOLDING AREA CAPABLE OFSTORING TOTAL OF 30 BINS
900
38
37
DRIVEWAYRAMP 1
DRIVEWAYRAMP 2+RL 9.14
+RL 9.14
DRIVEWAYRAMP 3
PEDESTRIANRAMP 1
PEDESTRIAN RAMP 2
PEDESTRIANRAMP 4
+RL 9.70
+RL 10.00
900
900
800mm RAISED FOOTHPATH WITH ROLLEDKERB AS PER CONDITION PART A 2.
TEMPORARY WALL AS PER THE REPORT
LOCATIONFOR WC
LOCATIONFOR WC
LOCATIONFOR WC
LETTERBOXES AND MAIL COLLECTIONFACILITIES PROVIDED IN ACCORDANCE WITHCONDITION 58
MAINTAIN EXISTING KERB
500mm DEEP PLANTER BELOW
DEEP SOIL PLANTING AREAS
+RL 9.70
+RL 9.76
KERB
LINEAR DRAIN
LOW RETAINING WALL ANDPLANTER TO LANDSCAPE SPEC
12m³ BULKY HOUSEHOLD WASTESTORAGE
HOSE COCK AND FLOOR WASTE TOHYDRAULIC ENGINEER'S DETAILS
900
CAFE EXHAUST RISER 800MM X 800MMCARPARK SUPPLY RISER 800MM X 400MMCARPARK EXHAUST RISER 1000MM X 400MM
+RL 10.36
UP
FW
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
4680
5400
4500
2450
8650
4180
4530
4970
5525
600
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
50 4565 8185 2450 6565 3560 3810 5745225
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
UP
+RL 9.70
300 2100 300
2350
200
490
300
3040
300
COMMUNAL COMPOSTING AS PER CONDITIONPART A 5 e) SEE WASTE CONSULTANT'SREPORT FOR MORE DETAILS
WC EXHAUST 450MM X 200MMGARBAGE EXHAUST RISER 450MM X 250MM
FFL 10.58
1625
1200
1625
600
+RL 9.70
+RL 9.90
+RL 9.93
+RL 9.77
+RL 9.84
+RL 10.58
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
U
26/06/2017 10:19:51 AM
110-112 ADDISON ROADMARRICKVILLE
S96-011 KAA1510
GROUND FLOOR PLAN
SECTION 96
scale - 1 : 200@ A3GROUND FLOOR1
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 22.02.17 REVISED ACCESSD 24.02.17 DEFERRED COMMENCEMENT ISSUEE 28.02.17 HYDRAULIC COORDINATIONF 06.03.17 HYDRAULIC COORDINATION R2G 07.03.17 CONSULTANT COORDINATION AH 13.03.17 STRUCTURAL REVIEWI 14.03.17 MECHANICAL ISSUEJ 14.03.17 LANDSCAPE ISSUEK 17.03.17 DRAFT CCL 27.03.17 CONSULTANT COORDINATION BM 28.03.17 CONSULTANT COORDINATION CN 10.04.17 ELEC. ISSUEO 11.04.17 MECH. ISSUEP 13.04.17 DRAFT S96 ISSUEQ 20.04.17 CONSULTANT COORDINATION DR 27.04.17 QS ISSUES 12.05.17 STRUCTURAL ISSUET 15.05.17 QS ISSUEU 16.05.17 S96 ISSUE
S96-153
1
S96-152
1
S96-151
1
AS96-160
AS96-160
H
H
G
G
F
F
C
C
B
B
A
A
01 01
02 02
03 03
04 04
05 05
07 07
4680
5400
4500
2450
8650
4180
4530
4970
5525
4565 8185 2450 6565 3560 3810 5745
08 08
06 06
1.A052 BED
1.A082 BED
1.A09 (A)1 BED
1.A103 BED
1.A021 BED+S
BALCONY
BALCONY
BALCONY
BALCONY
BALCONY
BALCONY
1.A031 BED
BALCONY
E
E
10 10
2200
LIFT B
6000
BALCONY
1.A01 (A)2 BED+S
09 09
D
D
1.A06 (A)1 BED
1.A042 BED
BALCONY(7.48 m²)
3790
2015
1.A073 BED
BS96-161
BS96-161
BALCONY
CS96-162
CS96-162
COMMON CIRCULATION
LIFT A
HIGHLIGHT WINDOWTO BATHROOMS
COMMON CIRCULATION (EXT. VENT.)(30.00 m²)
2475
7180 1032
0
2500 7000 (REAR SETBACK)
2300
LEVEL 2 PROFILE SHOWN DASHED
FIRE STAIR 2
LANDSCAPING
FIRE STAIR 1+RL 12.98STAIR
LANDING
EXISTING L1WINDOW
DS96-163
DS96-163
LIGHTWELL TOGROUND LEVEL
E
G/H/C
G/H/C
ALL NEW FIRE ISOLATED STAIR TO HAVESINGLE HANDRAIL COMPLYING WITHAS1428.1-2009 & STAIR NOSINGS
ALL NEW FIRE ISOLATED STAIR TO HAVESINGLE HANDRAIL COMPLYING WITHAS1428.1-2009 & STAIR NOSINGS
KIOSK SUBSTATION BELOW
E
3000
KIOS
KSU
BSTA
TION
1565
1550
H/C
FH
FH
5960
11005760
3200
3775
3265
3265
3195 3195
4535
3030
3030
2500
3485
4470
2300
2500
4130
32604060
3100
3030
1100
3030
4675
4000
3000
3000
3700
4690
3550
3655
3000
3140
3020
3470
3010
+RL 13.90
3275
2660
2650
2200 29
45
1410
1400
11
11
TRANSOM (OPERABLE) WINDOW ABOVE THE DOORACCORDING TO CONDITION 6
TRANSOM (OPERABLE) WINDOW ABOVE THE DOOR
WASTE & RECYCLING CHUTEACCORDING TO CONDITION PART A 5
WASTE & RECYCLING CHUTEACCORDING TO CONDITION PART A 5
I L L
A W
A R
R A
R
O A
D
A D D I S O N R O A D
BOUNDARY 3705m
m 74°10
'00"
BOUNDARY 33160mm 114°43'35"
BOUN
DARY
3933
0mm
33°3
5'55"
BOUNDARY 34920mm 303°41'35"
BOUN
DARY
2435
0mm
213°
56'30
"BO
UNDA
RY 91
450m
m 21
3°51
'20"
BOUN
DARY
1197
5mm
213°
55'20
"
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
4680
5400
4500
2450
8650
4180
4530
4970
5525
600
50 4565 8185 2450 6565 3560 3810 5745225
COMMON CIRCULATION TO HAVE FIXED GLASS OPENLOUVRES IN ACCORDANCE WITH CONDITION 5
3660
3055
3215
8265
1000
1025
1025
1025
1060
1530
1500
950
WC EXHAUST 450MM X 200MMGARBAGE EXHAUST RISER 450MM X 250MM
CAFE EXHAUST RISER 800MM X 800MMCARPARK SUPPLY RISER 800MM X 400MMCARPARK EXHAUST RISER 1000MM X 400MM
W2
W5
W6
W4
W3
W1
SD01SD02
SD02
SL13
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
T
26/06/2017 10:20:00 AM
110-112 ADDISON ROADMARRICKVILLE
S96-012 KAA1510
LEVEL 1 PLAN
SECTION 96
scale - 1 : 200@ A3LEVEL 11
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 24.02.17 DEFERRED COMMENCEMENT ISSUED 28.02.17 HYDRAULIC COORDINATIONE 06.03.17 HYDRAULIC COORDINATION R2F 07.03.17 CONSULTANT COORDINATION AG 13.03.17 STRUCTURAL REVIEWH 14.03.17 MECHANICAL ISSUEI 14.03.17 LANDSCAPE ISSUEJ 17.03.17 DRAFT CCK 27.03.17 CONSULTANT COORDINATION BL 28.03.17 CONSULTANT COORDINATION CM 10.04.17 ELEC. ISSUEN 11.04.17 MECH. ISSUEO 13.04.17 DRAFT S96 ISSUEP 20.04.17 CONSULTANT COORDINATION DQ 27.04.17 QS ISSUER 02.05.17 WALL TYPE REVIEWS 15.05.17 QS ISSUET 16.05.17 S96 ISSUE
S96-153
1
S96-152
1
S96-151
1
AS96-160
AS96-160
H
H
G
G
F
F
C
C
B
B
A
A
01 01
02 02
03 03
04 04
05 05
07 07
08 08
4680
5400
4500
2450
8650
4180
4530
4970
5525
2200
06 06
4565 8185 2450 6565 3560 3810 5745
BALCONY
E
E
10 10
LIFT B
09 09
D
D
2.A103 BED
2.A09 (A)1 BED
2.A082 BED
2.A073 BED
2.A041 BED
2.A01 (A)2 BED+S
2.A021 BED+S
BALCONYBALCONY
BALCONY
BALCONY
BALCONY
BALCONY
BALCONY
COMMON CIRCULATION
9050
BALCONY
BALCONY
8000
2.A06 (A)1 BED
725
BS96-161
BS96-161
CS96-162
CS96-162
COMMON CIRCULATION (EXT. VENT.)(30.00 m²)
HIGHLIGHT WINDOWTO BATHROOM
LIFT A
6000
7000
2300
2475
LEVEL 3 PROFILE SHOWNDASHED
LIGHTWELL TOGROUND LEVEL
NON TRAFFICABLE ROOF
2.A052 BED
FIRE STAIR 1
FIRE STAIR 2
+RL 15.52
STAIRLANDING
DS96-163
DS96-163
G/H/C
E16
00
H/C
FH
FH
1550
5745
3000
4105
3000
3000
3100
3195
4060
4075
4000
4740
3700
3550
3100
3000
7725
4530
2950 4535
3600
4185
3000
3030
E
G/H/C
3140
11
11
TRANSOM (OPERABLE) WINDOW ABOVE THE DOORACCORDING TO CONDITION 6
TRANSOM (OPERABLE) WINDOW ABOVE THE DOOR
ALL NEW FIRE ISOLATED STAIR TO HAVESINGLE HANDRAIL COMPLYING WITHAS1428.1-2009 & STAIR NOSINGS
ALL NEW FIRE ISOLATED STAIR TO HAVESINGLE HANDRAIL COMPLYING WITHAS1428.1-2009 & STAIR NOSINGS
WASTE & RECYCLING CHUTEACCORDING TO CONDITION PART A 5
WASTE & RECYCLING CHUTEACCORDING TO CONDITION PART A 5
2.A031 BED
2985
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
I L L
A W
A R
R A
R
O A
D
A D D I S O N R O A D
BOUNDARY 3705m
m 74°10
'00"
BOUNDARY 33160mm 114°43'35"
BOUN
DARY
3933
0mm
33°3
5'55"
BOUNDARY 34920mm 303°41'35"
BOUN
DARY
2435
0mm
213°
56'30
"BO
UNDA
RY 91
450m
m 21
3°51
'20"
BOUN
DARY
1197
5mm
213°
55'20
"
4680
5400
4500
2450
8650
4180
4530
4970
5525
600
50 4565 8185 2450 6565 3560 3810 5745225
COMMON CIRCULATION TO HAVE FIXED GLASS OPENLOUVRES IN ACCORDANCE WITH CONDITION 5
1500
WC EXHAUST 450MM X 200MMGARBAGE EXHAUST RISER 450MM X 250MM
CAFE EXHAUST RISER 800MM X 800MMCARPARK SUPPLY RISER 800MM X 400MMCARPARK EXHAUST RISER 1000MM X 400MM
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
S
26/06/2017 10:20:08 AM
110-112 ADDISON ROADMARRICKVILLE
S96-013 KAA1510
LEVEL 2 PLAN
SECTION 96
scale - 1 : 200@ A3LEVEL 21
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 24.02.17 DEFERRED COMMENCEMENT ISSUED 28.02.17 HYDRAULIC COORDINATIONE 06.03.17 HYDRAULIC COORDINATION R2F 07.03.17 CONSULTANT COORDINATION AG 13.03.17 STRUCTURAL REVIEWH 14.03.17 MECHANICAL ISSUEI 14.03.17 LANDSCAPE ISSUEJ 17.03.17 DRAFT CCK 27.03.17 CONSULTANT COORDINATION BL 28.03.17 CONSULTANT COORDINATION CM 10.04.17 ELEC. ISSUEN 11.04.17 MECH. ISSUEO 13.04.17 DRAFT S96 ISSUEP 20.04.17 CONSULTANT COORDINATION DQ 27.04.17 QS ISSUER 15.05.17 QS ISSUES 16.05.17 S96 ISSUE
S96-153
1
S96-152
1
S96-151
1
AS96-160
AS96-160
H
H
G
G
F
F
C
C
B
B
A
A
01 01
02 02
03 03
04 04
05 05
07 07
08 08
06 06
3.A032 BED+S
3.A063 BED
3.A083 BED
3.A021 BED+S
BALCONY
BALCONY
E
E
10 10
LIFT B
09 09
BALCONY
8000
BALCONY
D
D
4565 8185 2450 6565 3560 3810 5745
3.A07 (A)2 BED
BALCONY
3.A012 BED
BALCONY
BS96-161
BS96-161
3.A042 BED+S
BALCONY
CS96-162
CS96-162
LIFT A
71801870
4890 7710 1066
5
2475
COMMON CIRCULATION (EXT. VENT.)(30.03 m²)
COMMON CIRCULATION(11.77 m²)
BALCONY
FIRE STAIR 1
FIRE STAIR 2
+RL 18.57
STAIRLANDING
3970
DS96-163
DS96-163
LIGHTWELL TOGROUND LEVEL
G/H/C
LOFT ABOVESHOWN DASHED
E
1600
ROOF
2500
2000
H/C
FH
FH
ACCESS HATCH ABOVE TO ROOF/PLANT AREA
2610 7000
1550
SKYLIGHT
3725
3000
34153165
6503005
4030
2990
6280
4030
5280
8400
8815
5275
4380
2840
E
2200
VENTILATEDSKYLIGHT(VS1) ABOVE
11
11
TRANSOM (OPERABLE) WINDOW ABOVE THE DOORACCORDING TO CONDITION 6
ALL NEW FIRE ISOLATED STAIR TO HAVESINGLE HANDRAIL COMPLYING WITHAS1428.1-2009 & STAIR NOSINGS
ALL NEW FIRE ISOLATED STAIR TO HAVESINGLE HANDRAIL COMPLYING WITHAS1428.1-2009 & STAIR NOSINGS
WASTE & RECYCLING CHUTEACCORDING TO CONDITION PART A 5
WASTE & RECYCLING CHUTEACCORDING TO CONDITION PART A 5
CUTOUT OF ROOF ABOVECUTOUT OF ROOF ABOVE
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
I L L
A W
A R
R A
R
O A
D
A D D I S O N R O A D
BOUNDARY 3705m
m 74°10
'00"
BOUNDARY 33160mm 114°43'35"
BOUN
DARY
3933
0mm
33°3
5'55"
BOUNDARY 34920mm 303°41'35"
BOUN
DARY
2435
0mm
213°
56'30
"BO
UNDA
RY 91
450m
m 21
3°51
'20"
BOUN
DARY
1197
5mm
213°
55'20
"
4680
5400
4500
2450
8650
4180
4530
4970
5525
600
4680
5400
4500
2450
8650
4180
4530
4970
5525
50 4565 8185 2450 6565 3560 3810 5745225
COMMON CIRCULATION TO HAVE FIXED GLASS OPENLOUVRES IN ACCORDANCE WITH CONDITION 5
WC EXHAUST 450MM X 200MMGARBAGE EXHAUST RISER 450MM X 250MM
CAFE EXHAUST RISER 800MM X 800MMCARPARK SUPPLY RISER 800MM X 400MMCARPARK EXHAUST RISER 1000MM X 400MM
3105
1WD168
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
R
26/06/2017 10:20:17 AM
110-112 ADDISON ROADMARRICKVILLE
S96-014 KAA1510
LEVEL 3 PLAN
SECTION 96
scale - 1 : 200@ A3LEVEL 31
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 24.02.17 DEFERRED COMMENCEMENT ISSUED 28.02.17 HYDRAULIC COORDINATIONE 07.03.17 CONSULTANT COORDINATION AF 13.03.17 STRUCTURAL REVIEWG 14.03.17 MECHANICAL ISSUEH 14.03.17 LANDSCAPE ISSUEI 17.03.17 DRAFT CCJ 27.03.17 CONSULTANT COORDINATION BK 28.03.17 CONSULTANT COORDINATION CL 10.04.17 ELEC. ISSUEM 11.04.17 MECH. ISSUEN 13.04.17 DRAFT S96 ISSUEO 20.04.17 CONSULTANT COORDINATION DP 27.04.17 QS ISSUEQ 15.05.17 QS ISSUER 16.05.17 S96 ISSUE
S96-153
1
S96-152
1
S96-151
1
AS96-160
AS96-160
H
H
G
G
F
F
C
C
B
B
A
A
01 01
02 02
03 03
04 04
05 05
07 07
08 08
06 06
E
E
10 10
09 09
D
D
BS96-161
BS96-161
L.A042 BED+S
L.A032 BED+S
CS96-162
CS96-162
L.A012 BED
DS96-163
DS96-163
LIFTOVERRUN
LIFTOVERRUN
7340
L.A052 BED
ROOF / PLANT
SKYLIGHTABOVE
SKYLIGHT ABOVE
SKYLIGHTABOVE
OPERABLESKYLIGHTABOVE
SKYLIGHTABOVE
LADDER HATCH FROM THIRDFLOOR TO ROOF / PLANT
7755
SOLAR PANELS
FH
FHR
SKYLIGHT
3500
3410
3370
3000
3500
3530
3620
4000
3340
1070
OPERABLESKYLIGHTABOVE
OPERABLE SKYLIGHT ABOVE
OPERABLE SKYLIGHT ABOVE
11
11
CARPARKEXHAUST RISER
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
I L L
A W
A R
R A
R
O A
D
A D D I S O N R O A D
BOUNDARY 3705m
m 74°10
'00"
BOUNDARY 33160mm 114°43'35"
BOUN
DARY
3933
0mm
33°3
5'55"
BOUNDARY 34920mm 303°41'35"
BOUN
DARY
2435
0mm
213°
56'30
"BO
UNDA
RY 91
450m
m 21
3°51
'20"
BOUN
DARY
1197
5mm
213°
55'20
"
4680
5400
4500
2450
8650
4180
4530
4970
5525
600
4680
5400
4500
2450
8650
4180
4530
4970
5525
50 4565 8185 2450 6565 3560 3810 5745225
ANY AND ALL PLAN (INCLUDING AIR CONDITIONING) ISNOT TO PROJECT ABOVE THE HEIGHT OF THE ROOF INACCORDANCE WITH CONDITION 10
FLOOR WASTES TO HYDRAULICENGINEER'S REQUIREMENTS
PARAPET T.O.W. RL 23.15
STORAGE WITHINROOF SPACE
CUTOUT TO ROOF BELOW
CUTOUT TO ROOF BELOW
+RL 24.15
UP
UP
UPUP
UP
UP
UP
UP
UP
UP
WC EXHAUST 450MM X 200MMGARBAGE EXHAUST RISER 450MM X 250MM
HOTWATERPLANT
CAFE EXHAUST FAN
AIR CONDITIONING CONDENSER 1.5m HIGH
CAFE EXHAUST RISER 800MM X 800MMCARPARK SUPPLY RISER 800MM X 400MMCARPARK EXHAUST RISER 1000MM X 400MM
1WD168
+RL 23.03
+RL 23.03
AIR CONDITIONING CONDENSER 1.5m HIGH
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
Q
26/06/2017 10:38:36 AM
110-112 ADDISON ROADMARRICKVILLE
S96-015 KAA1510
LOFT LEVEL
SECTION 96
scale - 1 : 200@ A3LOFT LEVEL1
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 28.02.17 HYDRAULIC COORDINATIOND 07.03.17 CONSULTANT COORDINATION AE 13.03.17 STRUCTURAL REVIEWF 14.03.17 MECHANICAL ISSUEG 14.03.17 LANDSCAPE ISSUEH 17.03.17 DRAFT CCI 27.03.17 CONSULTANT COORDINATION BJ 28.03.17 CONSULTANT COORDINATION CK 10.04.17 ELEC. ISSUEL 11.04.17 MECH. ISSUEM 13.04.17 DRAFT S96 ISSUEN 20.04.17 CONSULTANT COORDINATION DO 27.04.17 QS ISSUEP 15.05.17 QS ISSUEQ 16.05.17 S96 ISSUE
S96-153
1
S96-152
1
S96-151
1
AS96-160
AS96-160
H
H
G
G
F
F
C
C
B
B
A
A
01 01
02 02
03 03
04 04
05 05
07 07
08 08
06 06
E
E
10 10
09 09
D
D
BS96-161
BS96-161
CS96-162
CS96-162
DS96-163
DS96-163
SKYLIGHT
SKYLIGHT
SKYLIGHT
OPERABLESKYLIGHT
SKYLIGHT
I L L
A W
A R
R A
R
O A
D
A D D I S O N R O A D
BOUNDARY 3705m
m 74°10
'00"
BOUNDARY 33160mm 114°43'35"
BOUN
DARY
3933
0mm
33°3
5'55"
BOUNDARY 34920mm 303°41'35"
BOUN
DARY
2435
0mm
213°
56'30
"BO
UNDA
RY 91
450m
m 21
3°51
'20"
BOUN
DARY
1197
5mm
213°
55'20
"
No 108ADDISON ROAD
EXISTING 2 STOREYRETAIL BUILDING
No 1ILLAWARA ROAD
EXISTING 2 STOREYRESIDENTIAL BUILDING
BRICK & WEATHERBOARDEXISTING 2 STOREY BUILDING
H A N D L E Y S T R E E T
Y O
R K
S T
R E
E T
PVC
ROOF / PLANT BELOW
OPERABLESKYLIGHT
OPERABLESKYLIGHT
OPERABLESKYLIGHT
11
1025
1025
1025INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
GRID
LINES
STRU
CTUR
AL C
OLUM
NS
BUILD
ING
SETB
ACK
EXTE
RNAL
WAL
LS
INTE
RNAL
WAL
LS
GRIDLINES
STRUCTURAL COLUMNS
EXTERNAL WALLS
INTERNAL WALLS
BUILDING SETBACK
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
SIDE DISCHARGE OFBASEMENT EXHAUST
+RL HOB 25.55
+RL HOB 25.55
+RL HOB 25.55
+RL HOB 25.55
+RL HOB 25.55
+RL HOB 25.55
+RL 25.95
+RL 26.15
+RL 25.95
+RL 25.95
+RL 23.03
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
O
26/06/2017 10:38:43 AM
110-112 ADDISON ROADMARRICKVILLE
S96-016 KAA1510
ROOF PLAN
SECTION 96
scale - 1 : 200@ A3ROOF PLAN1
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 07.03.17 CONSULTANT COORDINATION AD 14.03.17 MECHANICAL ISSUEE 14.03.17 LANDSCAPE ISSUEF 17.03.17 DRAFT CCG 27.03.17 CONSULTANT COORDINATION BH 28.03.17 CONSULTANT COORDINATION CI 10.04.17 ELEC. ISSUEJ 11.04.17 MECH. ISSUEK 13.04.17 DRAFT S96 ISSUEL 20.04.17 CONSULTANT COORDINATION DM 27.04.17 QS ISSUEN 15.05.17 QS ISSUEO 16.05.17 S96 ISSUE
1.A09 (A)
1.A01 (A)
1.A06 (A)
2.A01 (A)
2.A06 (A)
2.A09 (A)
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 500
5m 10m2.5m 20m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
I
26/06/2017 10:20:45 AM
110-112 ADDISON ROADMARRICKVILLE
S96-102 KAA1510
ADAPTABLE UNITS
SECTION 96
scale - 1 : 500@ A3GROUND FLOOR - ADAPTABLE UNITS1
scale - 1 : 500@ A3ROOF / LOFT - ADAPTABLE UNITS2
scale - 1 : 500@ A3LEVEL 1 - ADAPTABLE UNITS3
scale - 1 : 500@ A3LEVEL 2 - ADAPTABLE UNITS4
scale - 1 : 500@ A3LEVEL 3 - ADAPTABLE UNITS5
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 24.02.17 DEFERRED COMMENCEMENT ISSUED 07.03.17 CONSULTANT COORDINATION AE 17.03.17 DRAFT CCF 13.04.17 DRAFT S96 ISSUEG 27.04.17 QS ISSUEH 15.05.17 QS ISSUEI 16.05.17 S96 ISSUE
ø 2250
ø 1550
3210
F P
1550
L
510 880
800
880
510
110
880
5301450
510
1450
300
110
880
530
880
1450
ø 1000
ø 1000
530 880 110
1450
1450
R
F P
L
DOUBLE POWER OUTLET FORPOTENTIAL ACCESSIBLEAUTOMATED DOOR.
ø 1550
ø 2250
ø 1000
2350
880 510
1450
1450
880110
800
315
1550
1550
1000
PUSH BUTTON TOAUTOMATED DOOR
240
530
1220
1450
2350
530
880
1520
660
880
240
1240
880
R
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 100
1m 2m0.5m 4m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
I
26/06/2017 10:20:48 AM
110-112 ADDISON ROADMARRICKVILLE
S96-103 KAA1510
PRE/POST ADAPTABLEUNITS-LEVEL 1 & 2
SECTION 96
scale - 1 : 100@ A3LEVEL 1&2 - POST-ADAPTABLE UNIT A012
scale - 1 : 100@ A3LEVEL 1&2 - PRE-ADAPTABLE UNIT A015
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 24.02.17 DEFERRED COMMENCEMENT ISSUED 07.03.17 CONSULTANT COORDINATION AE 17.03.17 DRAFT CCF 13.04.17 DRAFT S96 ISSUEG 27.04.17 QS ISSUEH 15.05.17 QS ISSUEI 16.05.17 S96 ISSUE
scale - 1 : 100@ A3LEVEL 1 & 2 - PRE-ADAPTABLE UNIT A061
scale - 1 : 100@ A3LEVEL 1 & 2 - POST-ADAPTABLE UNIT A063
FLOORING TO RUN UNDERCUPBOARD SHOWN HATCHED.
DOUBLE POWER OUTLET FORPOTENTIAL ACCESSIBLEAUTOMATED DOOR
ø 1000
ø 1550
ø 2250
1550
800300
ø 1000
1500
AUTOMATED ENTRYDOOR
510
1450
530
110
1500
880
880
1000
510
880
14501450
530
880
110R
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 100
1m 2m0.5m 4m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
I
26/06/2017 10:20:49 AM
110-112 ADDISON ROADMARRICKVILLE
S96-104 KAA1510
PRE/POST ADAPTABLEUNITS-LEVEL 1 & 2
SECTION 96
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 20.02.17 REVISED BIN ROOMC 24.02.17 DEFERRED COMMENCEMENT ISSUED 07.03.17 CONSULTANT COORDINATION AE 17.03.17 DRAFT CCF 13.04.17 DRAFT S96 ISSUEG 27.04.17 QS ISSUEH 15.05.17 QS ISSUEI 16.05.17 S96 ISSUE
scale - N.T.S.LEVEL 1 & 2 - PRE-ADAPTABLE UNIT A091
scale - N.T.S.LEVEL 1 & 2 - POST-ADAPTABLE UNIT A092
LEVEL 1FFL 13.90
LOFT LEVELFFL 22.75
GROUND FLOORFFL 10.60
LEVEL 2FFL 16.95
LEVEL 3FFL 20.00
H G F C B AE D
ROOFFFL 25.55
GROUND FLOOR - BFFL 9.70
EAST
BOU
NDAR
Y
WES
T BO
UNDA
RY
CS96-162
CS96-162
LINE OF 14m BUIDLING HEIGHT LIMITFROM NATURAL GROUND LEVEL
ILLAWARRA ROAD
3300
3050
3050
2750
2800
SIGHT LINE FROMILLAWARRA ROAD
LINE OF 14m BUIDLING HEIGHTLIMIT FROM FREEBOARD RL10.60
ADDISON ROAD
ANY AND ALL PLANT (INCLUDING AIRCONDITIONING) IS NOT TO PROJECTABOVE THE HEIGHT OF THE ROOFACCORDING TO CONDITION 10
THE INFILL TO THE BALUSTRADE FOR THEACCESSIBLE RAMP FRONTING ADDISON ROAD IS TOBE CLEAR GLAZING ACCORDING TO CONDITION 2.
RL 26.150
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
H
26/06/2017 10:30:44 AM
110-112 ADDISON ROADMARRICKVILLE
S96-150 KAA1510
ADDISON ROAD ELEVATION -NORTH
SECTION 96
scale - 1 : 200@ A3ADDISON ROAD ELEVATION - NORTH1
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 07.03.17 CONSULTANT COORDINATION AC 17.03.17 DRAFT CCD 13.04.17 DRAFT S96 ISSUEE 20.04.17 CONSULTANT COORDINATION DF 27.04.17 QS ISSUEG 15.05.17 QS ISSUEH 16.05.17 S96 ISSUE
LEVEL 1FFL 13.90
LOFT LEVELFFL 22.75
GROUND FLOORFFL 10.60
LEVEL 2FFL 16.95
LEVEL 3FFL 20.00
AS96-160
AS96-160
01 02 03 04 05 07 0806 1009
ROOFFFL 25.55
GROUND FLOOR - BFFL 9.70
2800
2750
3050
3050
3300
900
BS96-161
BS96-161
SOUT
H BO
UNDA
RY
FRON
T NO
RTH
BOUN
DARY
REAR
NOR
TH B
OUND
ARY
LINE OF 14m BUILDING HEIGHT LIMITFROM NATURAL GROUND LEVEL
ILLAWARRA ROAD
DS96-163
DS96-163
FIRE HYDRANT BOOSTER
LINE OF 14m BUILDING HEIGHT LIMITFROM FREEBOARD RL10.60
ANY AND ALL PLANT (INCLUDING AIR CONDITIONING)IS NOT TO PROJECT ABOVE THE HEIGHT OF THEROOF ACCORDING TO CONDITION 10
RL 26.150 RL 25.950
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
H
26/06/2017 10:21:15 AM
110-112 ADDISON ROADMARRICKVILLE
S96-151 KAA1510
ILLAWARRA ROAD ELEVATION -WEST
SECTION 96
scale - 1 : 200@ A3ILLAWARA ROAD ELEVATION - WEST1
ADDISON ROAD
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 07.03.17 CONSULTANT COORDINATION AC 17.03.17 DRAFT CCD 13.04.17 DRAFT S96 ISSUEE 20.04.17 CONSULTANT COORDINATION DF 27.04.17 QS ISSUEG 15.05.17 QS ISSUEH 16.05.17 S96 ISSUE
LEVEL 1FFL 13.90
LOFT LEVELFFL 22.75
GROUND FLOORFFL 10.60
LEVEL 2FFL 16.95
LEVEL 3FFL 20.00
HGFCBA ED
ROOFFFL 25.55
1WD165
1WD165
GROUND FLOOR - BFFL 9.70
No. 1 ILLAWARRA ROAD INFOREGROUND SHOWN DASHED
2800
2750
3050
3050
3300
900
EAST
BOU
NDAR
Y
WES
T BO
UNDA
RY
CS96-162
CS96-162
ILLAWARRA ROAD
LINE OF 14m BUILDINGHEIGHT LIMIT FROMNATURAL GROUND LEVEL
NO.108 ADDISON ROAD NO.106 ADDISON ROAD NO.104 ADDISON ROAD NO.102 ADDISON ROAD NO.100 ADDISON ROAD
HANDLEY STREET
REFER DERFERRED COMMENCEMENT REPORT &THE STRUCTURAL ENGINEER'S LETTER FORDETAILS ON EXISTING BOUNDARY WALL SHOWNDASHED IN REGARDS TO CONDITION PART A 3.
LINE OF 14m BUILDINGHEIGHT LIMIT FROMFREEBOARD RL10.60
HANDLEY WAY
ANY AND ALL PLANT (INCLUDING AIR CONDITIONING) ISNOT TO PROJECT ABOVE THE HEIGHT OF THE ROOFACCORDING TO CONDITION 10
RL 25.550RL 26.150 RL 25.950
+RL 24.55
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
I
26/06/2017 10:21:28 AM
110-112 ADDISON ROADMARRICKVILLE
S96-152 KAA1510
SOUTH ELEVATION
SECTION 96
scale - 1 : 200@ A3HANDLEY WAY ELEVATION - SOUTH1
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 24.02.17 DEFERRED COMMENCEMENT ISSUEC 07.03.17 CONSULTANT COORDINATION AD 17.03.17 DRAFT CCE 13.04.17 DRAFT S96 ISSUEF 20.04.17 CONSULTANT COORDINATION DG 27.04.17 QS ISSUEH 15.05.17 QS ISSUEI 16.05.17 S96 ISSUE
LEVEL 1FFL 13.90
LOFT LEVELFFL 22.75
GROUND FLOORFFL 10.60
LEVEL 2FFL 16.95
LEVEL 3FFL 20.00
AS96-160
AS96-160
01020304050708 0610 09
ROOFFFL 25.55
GROUND FLOOR - BFFL 9.70
No. 108 ADDISION ROAD
2800
2750
3050
3050
3300
900
BS96-161
BS96-161
No. 1ILLAWARRAROAD
SOUT
H BO
UNDA
RY
NORT
H BO
UNDA
RY
LINE OF 14m BUILDING HEIGHT LIMITFROM NATURAL GROUND LEVEL
ADDISON ROAD
SEC-34 PROFILE SHOWN DASHED
DS96-163
DS96-163 LINE OF 14m BUILDING HEIGHT
LIMIT FROM FREEBOARD RL10.60
ANY AND ALL PLANT (INCLUDING AIR CONDITIONING) ISNOT TO PROJECT ABOVE THE HEIGHT OF THE ROOFACCORDING TO CONDITION 10
RL 25.550RL 26.150RL 25.950
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
H
26/06/2017 10:21:41 AM
110-112 ADDISON ROADMARRICKVILLE
S96-153 KAA1510
EAST ELEVATION
SECTION 96
scale - 1 : 200@ A3EAST ELEVATION1
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 07.03.17 CONSULTANT COORDINATION AC 17.03.17 DRAFT CCD 13.04.17 DRAFT S96 ISSUEE 20.04.17 CONSULTANT COORDINATION DF 27.04.17 QS ISSUEG 15.05.17 QS ISSUEH 16.05.17 S96 ISSUE
LEVEL 1FFL 13.90
LOFT LEVELFFL 22.75
GROUND FLOORFFL 10.60
LEVEL 2FFL 16.95
LEVEL 3FFL 20.00
BASEMENTFFL 6.78
2800
2750
3050
3050
3300
3820
HGFCBA E
+RL 10.60
D
ROOFFFL 25.55
GROUND FLOOR - BFFL 9.70
ILLAWARRA ROAD
REAR OF No.106ADDISON ROAD
LIFTSHAFT
SIGHT LINE FROMILLAWARRA ROAD
REAR OF No.104ADDISON ROAD
REAR OFNo.122
ADDISONROAD
EAST
BOU
NDAR
Y
WES
T BO
UNDA
RY
HANDLEY STREET
REAR OF No.102ADDISON ROAD
2520
LINE OF 14m BUILDING HEIGHTLIMIT FROM NATURAL GROUNDLEVEL
LINE OF 14m BUILDING HEIGHTLIMIT FROM FREEBOARD RL10.60
3.A032 BED+S
2.A041 BED
1.A042 BED
2.A01 (A)2 BED+S
L.A012 BED
L.A032 BED+S
G.C02COMMERCIAL
1.A01 (A)2 BED+S
ANY AND ALL PLANT (INCLUDING AIR CONDITIONING)IS NOT TO PROJECT ABOVE THE HEIGHT OF THEROOF ACCORDING TO CONDITION 10
RL 25.550RL 26.150 RL 25.950
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
H
26/06/2017 10:22:02 AM
110-112 ADDISON ROADMARRICKVILLE
S96-160 KAA1510
SECTION AA
SECTION 96
1 : 200SECTION AAA
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 07.03.17 CONSULTANT COORDINATION AC 17.03.17 DRAFT CCD 13.04.17 DRAFT S96 ISSUEE 20.04.17 CONSULTANT COORDINATION DF 27.04.17 QS ISSUEG 15.05.17 QS ISSUEH 16.05.17 S96 ISSUE
LEVEL 1FFL 13.90
LOFT LEVELFFL 22.75
GROUND FLOORFFL 10.60
LEVEL 2FFL 16.95
LEVEL 3FFL 20.00
BASEMENTFFL 6.78
HGFCBA ED
ROOFFFL 25.55
GROUND FLOOR - BFFL 9.70
REAR OF No.106ADDISON ROAD
2800
2750
3050
3050
3300
900
2920
LINE OF 14m BUILDING HEIGHTLIMIT FROM NATURAL GROUNDLEVEL
1400
0
2.A052 BED
1.A052 BED
3.A042 BED+S
L.A032 BED+S
3.A052 BED
2.A06 (A)1 BED
1.A06 (A)1 BED
G.C03COMMERCIAL
RL 13.400
WES
T BO
UNDA
RY
EAST
BOU
NDAR
Y
PEDESTRIANLINE OF SIGHT
REAR OFNo.122
ADDISONROAD
REAR OFNo.104
ADDISONROAD
ILLAWARRA ROAD
2190
ROAD
LINE OF 14m BUILDING HEIGHTLIMIT FROM FREEBOARD RL10.60
+RL 23.30
2305
ANY AND ALL PLANT (INCLUDING AIR CONDITIONING)IS NOT TO PROJECT ABOVE THE HEIGHT OF THEROOF ACCORDING TO CONDITION 10
RL 25.550
L.A052 BED
RL 26.150
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
H
26/06/2017 10:22:15 AM
110-112 ADDISON ROADMARRICKVILLE
S96-161 KAA1510
SECTION BB
SECTION 96
scale - 1 : 200@ A3SECTION BBB
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 07.03.17 CONSULTANT COORDINATION AC 17.03.17 DRAFT CCD 13.04.17 DRAFT S96 ISSUEE 20.04.17 CONSULTANT COORDINATION DF 27.04.17 QS ISSUEG 15.05.17 QS ISSUEH 16.05.17 S96 ISSUE
LEVEL 1FFL 13.90
LOFT LEVELFFL 22.75
GROUND FLOORFFL 10.60
LEVEL 2FFL 16.95
LEVEL 3FFL 20.00
BASEMENTFFL 6.78
01 02 03 04 05 07 0806 1009
ROOFFFL 25.55
GROUND FLOOR - BFFL 9.70
LINE OF 14m BUILDING HEIGHT LIMITFROM NATURAL GROUND LEVEL
SOUT
H BO
UNDA
RY
REAR
NOR
TH B
OUND
ARY
ADDISON ROAD
3.A063 BED
2.A082 BED
1.A082 BED
G.R04CAFE / RESTAURANT COMMON CIRCULATION (EXT. VENT.)
2.A06 (A)1 BED
1.A06 (A)1 BED
3.A052 BED
LIFT ASHAFT
LIFT BSHAFT
ROLLERSHUTTER
1&3 ILLAWARRA ROAD
1&3 ILLAWARRA ROADIN FOREGROUND
LINE OF 14m BUILDING HEIGHT LIMITFROM FREEBOARD RL10.6
PEDESTRIANSIGHT LINE
ANY AND ALL PLANT (INCLUDING AIR CONDITIONING) ISNOT TO PROJECT ABOVE THE HEIGHT OF THE ROOFACCORDING TO CONDITION 10
600
RL 25.550RL 26.150 RL 25.950
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
G
26/06/2017 10:22:33 AM
110-112 ADDISON ROADMARRICKVILLE
S96-162 KAA1510
SECTION CC
SECTION 96
scale - 1 : 200@ A3SECTION CCC
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 07.03.17 CONSULTANT COORDINATION AC 17.03.17 DRAFT CCD 13.04.17 DRAFT S96 ISSUEE 20.04.17 CONSULTANT COORDINATION DF 27.04.17 QS ISSUEG 15.05.17 QS ISSUE
LEVEL 1FFL 13.90
LOFT LEVELFFL 22.75
GROUND FLOORFFL 10.60
LEVEL 2FFL 16.95
LEVEL 3FFL 20.00
BASEMENTFFL 6.78
HGFCBA ED
ROOFFFL 25.55
GROUND FLOOR - BFFL 9.70
FIREEXIT
1 ILLAWARRAROAD INFOREGROUND
1700
600
800
+RL 6.20 +RL 6.20
LINE OF 14m BUILDING HEIGHT LIMITFROM NATURAL GROUND LEVEL
LINE OF 14m BUILDING HEIGHT LIMITFROM FREEBOARD RL10.60
REFER DERFERRED COMMENCEMENT REPORT &THE STRUCTURAL ENGINEER'S LETTER FORDETAILS ON EXISTING BOUNDARY WALL SHOWNDASHED IN REGARDS TO CONDITION PART A 3.
WES
T BO
UNDA
RY
EAST
BOU
NDAR
Y
RL 25.550RL 26.150 RL 25.950
0
DRAWING NO: ISSUE NO: JOB NO:
PROJECT NAME:
DRAWING TITLE:
NOMINATED ARCHITECTPATRICK NICHOLASNSW 6672 QLD 4699 VIC18105
ARCHITECTSNICHOLAS +ASSOCIATES
SUITE 61 MARY'S PLACE
SURRY HILLS NSW 2010T + 61 2 8353 9500 ANPLUSA.COM
PLOTTED :
Scale 1 : 200
2m 4m1m 8m
@ A3
© THIS WORK IS COPYRIGHT. APART FROM ANY USEPERMITTED UNDER THE COPYRIGHT ACT 1968, NO PARTMAY BE REPRODUCED BY ANY PROCESS, NOR MAYANY OTHER EXCLUSIVE RIGHT BE EXERCISED,WITHOUT THE PERMISSION OF ARCHITECTS NICHOLAS& ASSOCIATES PTY LTD, STUDIO 6, LEVEL 2, 1 MARY'SPLACE, SURRY HILLS NSW 2010 AUSTRALIA.
EQUITY SITE HOLDINGS PTY LTD
LALLEES ENTERPRISES PTY LTD
CLIENT:
PROJECT MANAGER:
DO NOT SCALE DRAWING. VERIFY ALLDIMENSIONS ON SITE.REPORT ANY DISCREPANCIES INDOCUMENTATION TO ARCHITECT.THIS DRAWING IS FOR THE PURPOSEOF CONSTRUCTION CERTIFICATEAPPROVAL AND AS SUCH, IS NOTSUITABLE FOR CONSTRUCTION.
I
26/06/2017 10:22:56 AM
110-112 ADDISON ROADMARRICKVILLE
S96-163 KAA1510
SECTION DD
SECTION 96
scale - 1 : 200@ A3SECTION DDD
ISS DATE PURPOSE OF ISSUEA 16.01.17 CC FEE PROP ISSUEB 24.02.17 DEFERRED COMMENCEMENT ISSUEC 07.03.17 CONSULTANT COORDINATION AD 17.03.17 DRAFT CCE 13.04.17 DRAFT S96 ISSUEF 20.04.17 CONSULTANT COORDINATION DG 27.04.17 QS ISSUEH 15.05.17 QS ISSUEI 16.05.17 S96 ISSUE