Gutter Connection.pdf

Embed Size (px)

Citation preview

  • 8/14/2019 Gutter Connection.pdf

    1/8

    SheetJob Number

    Job Title

    Client

    Calcs by Checked by Date

    Software Consultants (Pty) Ltd

    Internet: http://www.prokon.com

    E-Mail : [email protected]

    S17

    Bolted Double Angle Cleat Connection - Ver W1.7.00 - 3 Oct 2000

    Title : Default ConnectionCode of Practice : Eurocode 3 - 1992Created : 5/3/2013 8:28:52 AM

    Notes and Assumptions

    1 Bolts are referred to by column and row number. Columns arenumbered from left to right, and rows from top to bottom.

    2 All bolt holes are assumed to be normal clearance holes.3 All bolts are assumed to have threads in their shear planes.

    Summary

    Summary of Forces and Capacities for Design to Eurocode 3 - 1992

    Check Member Type LC Applied Capacity Units % of Cap. ?

    1 Cleat Length/Beam Depth D + L 0.6 0.7 Ratio 81.3 O.K.

    2a Beam Bolts Shear D + L 81.4 591.4 kN 13.8 O.K.

    2b Beam Bolts Slip D + L 72.1 403.6 kN 17.9 O.K.

    3a Cleat to Beam Linear Shear D + L 32.5 158.7 kN 20.5 O.K.

    3b Cleat to Beam Bearing D + L 14.5 31.2 kN 46.3 O.K.

    4a Beam web Linear Shear D + L 65 182.7 kN 35.6 O.K.

    4b Beam web Block Shear D + L 81.4 153 kN 53.2 O.K.

    4c Beam web Bearing D + L 28.9 29.7 kN 97.3 O.K.

    5a Col. Bolts Shear D + L 10.8 188 kN 5.8 O.K.

    5b Col. Bolts Tension N/A 0 1 kN 0.0 O.K.

    5b Col. Bolts Tension N/A 0 1 kN 0.0 O.K.

    5c Col. Bolts Combined N/A 0.0 1.0 Ratio 0.0 O.K.

    5d Col. Bolts Slip D + L 10 60.8 kN 16.5 O.K.

    5e Col. Bolts Combined N/A 0 1 kN 0.0 O.K.

    6a Cleat to Col. Linear Shear D + L 32.5 158.7 kN 20.5 O.K.

    6b Cleat to Col. Bearing D + L 10.8 32.5 kN 33.3 O.K.

    7 Column Bearing D + L 10.8 127.9 kN 8.5 O.K.

  • 8/14/2019 Gutter Connection.pdf

    2/8

    SheetJob Number

    Job Title

    Client

    Calcs by Checked by Date

    Software Consultants (Pty) Ltd

    Internet: http://www.prokon.com

    E-Mail : [email protected]

    Input

    Bolt Shear Analysis

    Bolt Type

    Bolt GradeBolt Size (mm)

    Member Ultimate Strength (MPa)

    Member Yield Strength (MPa)

    Non-Linear

    HSFG

    8.820

    450

    284

    Member Type Designation

    Column

    Beam

    CleatSpace between beam and column (mm)

    Beam Angle

    Cleat Length (mm)

    Cleat offset from top of beam (mm)

    H-sections (Paral lel f lange) 254x254x73

    I-sections (Paral lel f lange) 203x133x25

    Angles (Unequal leg) 125x75x8

    10

    0.0

    150

    25

    Cleats Conn Flange

    Longest Leg Beam

    Column Connection (per Cleat)

    Columns of Bolts

    Rows of Bolts

    Top Edge (mm)

    Side Edge (mm)

    Column Pitch (mm)

    Row Pitch (mm)

    1

    3

    25

    25

    Not Applicable

    50

  • 8/14/2019 Gutter Connection.pdf

    3/8

    SheetJob Number

    Job Title

    Client

    Calcs by Checked by Date

    Software Consultants (Pty) Ltd

    Internet: http://www.prokon.com

    E-Mail : [email protected]

    Beam Connection

    Columns of Bolts

    Rows of Bolts

    Top Edge (mm)

    Side Edge (mm)

    Column Pitch (mm)

    Row Pitch (mm)

    2

    3

    25

    24

    48

    50

    Shear

    Axial

    Loads

    Load CaseUltimate Loads Service Loads

    Shear (kN) Axial (kN) Shear (kN) Axial (kN)

    D + L 65 49 60 40

    Plan Section

    14.0 226.0 10.0

    48 24

    254.0 125.0

    254.0

    133.4

    25

  • 8/14/2019 Gutter Connection.pdf

    4/8

    SheetJob Number

    Job Title

    Client

    Calcs by Checked by Date

    Software Consultants (Pty) Ltd

    Internet: http://www.prokon.com

    E-Mail : [email protected]

    Elevation

    5

    0.0

    50.0

    25.0

    5

    0.0

    50.0

    25.0

    Beam Section

    50.0

    25.0

    50.0

    25.0

  • 8/14/2019 Gutter Connection.pdf

    5/8

    SheetJob Number

    Job Title

    Client

    Calcs by Checked by Date

    Software Consultants (Pty) Ltd

    Internet: http://www.prokon.com

    E-Mail : [email protected]

    Check 1 : Recommended Detailing Requirements

    ( A ratio of >0.6 is recommended for Lateral Tortional Stability )

    Check 2a : Shear Capacity of the Supported Beam Bolt Group

    6.5.5

    The worst load is encountered for Load Case : D + L when Fmax=81.4 kN

    The resistance for the configuration is computed to beR = 591.4 kN

    Beam bolt shear is safe

    Check 2b : Slip of the Beam HSFG Bolts

    The worst load is encountered for Load Case : D + Lwhere Fsmax= 72.1 kN

    The Capacity of the connection is 403.6 kN6.5.8

  • 8/14/2019 Gutter Connection.pdf

    6/8

    SheetJob Number

    Job Title

    Client

    Calcs by Checked by Date

    Software Consultants (Pty) Ltd

    Internet: http://www.prokon.com

    E-Mail : [email protected]

    Beam bolt slip is safe

    Check 3a: Shear Capacity of the Cleats to the Beam

    The Worst load is encountered for Load Case : D + Lwith Fv.Sd= 32.5 kNThe Linear Shear Capacity of the Cleat is :

    5.4.6

    Cleat to beam Shear is safe

    Check 3b: Bearing Capacity of the Cleats to the Beam

    With the maximum force at the Bolt in Column 2 and Row 3for Load Case : D + LFv.Sd= 65 kN

    The Bearing Capacity of the Cleat at any Bolt is :Table 6.5.3

  • 8/14/2019 Gutter Connection.pdf

    7/8

    SheetJob Number

    Job Title

    Client

    Calcs by Checked by Date

    Software Consultants (Pty) Ltd

    Internet: http://www.prokon.com

    E-Mail : [email protected]

    Cleat to beam bearing is safe

    Check 4a: Linear Shear Capacity of the Beam Web

    The Worst load is encountered for Load Case : D + L

    with VSd= 65 kNThe Linear Shear Capacity of the beam is :

    5.4.6

    Linear beam web Shear is safe

    Check 4b : Block Shear Capacity of the Beam Web

    The Maximum force occurs for Load Case : D + LFv.Sd= 81.4 kN

    6.5.2.2

    Beam web block shear is safe

  • 8/14/2019 Gutter Connection.pdf

    8/8

    SheetJob Number

    Job Title

    Client

    Calcs by Checked by Date

    Software Consultants (Pty) Ltd

    Internet: http://www.prokon.com

    E-Mail : [email protected]

    Check 4c: Bearing Capacity of the beam web

    With the maximum force at the Bolt in Column 1 and Row 1for Load Case : D + LFv.Sd= 28.9 kN

    The Bearing Capacity of the beam web is :Table 6.5.3

    Beam web bearing is safe

    Check 5a : Shear Capacity of the Column Bolt Group

    The worst load is encountered for Load Case : D + L when Fv.Sd=10.8 kN

    6.5.5