Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
H A N B A C K E L E C T R O N I C S232
>>IT Convergence
HBE-Healthcare LABApplication of octa core high performance processorThe sensor data acquisition based on cortex-M4Measurement for 9 kinds of Bio-signalCompatible with the Arduino boardLearning Bio-signal processingApplicable to specific Project design
At the time when the paradigm of health care is changed from the post treatment to the prevention and health care, 9-Bio-Signal Analysis and Monitoring functions are included in HBE-HealthCare LAB equipment. Through ICT convergence interacting with smart device, core technology of U-Health care can be learned.
The equipment that can learn and master Bio-signal analysis, algorithm implementation principle and the operation principle of the bio-signal filter.To provide the bio-signal generator of ECG and Respiration.To be capable of analyzing the bio-signal acquisition process through 2 ch oscilloscope .Possible to educate MCU based on Cortex M4, and Bio-signal measurement module can be used to mount the Arduino board.To provide bio-signal App of 1ch-ECG, 10ch-ECG, EMG, EEG, GSR, SpO2, Respiration, NIBP, Bio-Impedance and so on.To be composed of a variety of bio-signal circuit module for the system design technique and algorithm analysis. To support Interface to be available to easily work with Android system, Arduino for a comprehensive application.To support to be used for Capstone and creative engineering design through the bio-signal measuring module.
Medical care, Healthcare and ICT
Introduction
Features
HBE-PC Base Control
IT Convergence
HBE-HealthCare LAB
H A N B A C K E L E C T R O N I C S 233
HANBACK ELECTRONICSw w w.hanback .com
Since 1984
HBE-HealthCare LAB
Cortex-M4CPU Oscilloscope
2ch
TFT LCDBiological
Signal Generator
ExperimentBoard NIBP
SpO2
Respiration
GSR
Bio-Impedance
Accessory
10ch-ECG
ECG
EMG
1ch-ECG
Ethernet
Cortex-M4MCU
ECG
Respiration
BioImpedance
EMG
EEG
GSR
NIBP
SpO2
8ch ECG
Cortex-M4MCU
ExtensionI/O
ADC SPI
ADC
ADC
ADC
ADC
I2C
SPI
SPI
Embedded PC(Exynos 5422)
7” LCDTouchUSB 2.0 USB 2.0
USB OTG
Ethernet
eMMCTFlash
USB
Bread Board
Experimental circuit implementation
PowerAC/DC Converter 2ch up to 30Msps
OscilloscopeBiological
Signal Generator
ECG
Cortex-M4 MCU
+5V +12V USB CH1 CH2
Cortex-M4MCU
ECG
Respiration
BioImpedance
EMG
EEG
GSR
NIBP
SpO2
8ch ECG
Cortex-M4MCU
ExtensionI/O
ADC SPI
ADC
ADC
ADC
ADC
I2C
SPI
SPI
Embedded PC(Exynos 5422)
7” LCDTouchUSB 2.0 USB 2.0
USB OTG
Ethernet
eMMCTFlash
USB
Bread Board
Experimental circuit implementation
PowerAC/DC Converter 2ch up to 30Msps
OscilloscopeBiological
Signal Generator
ECG
Cortex-M4 MCU
+5V +12V USB CH1 CH2
Cortex-M
4M
CU
ECG
Resp
iration
Bio
Imped
ance
EMG
EEG
GSR
NIB
P
SpO
2
8ch EC
G
Cortex-M
4M
CU
Extensio
nI/O
ADC
SPI
ADC
ADC
ADC
ADC
I2C
SPI
SPI
Embed
ded
PC
(Exynos 5422)
7” LCD
Touch
USB
2.0USB
2.0
USB
O
TGEth
ernet
eMM
CTFlash
USB
Bread
Board
Experim
ental circu
it im
plem
entatio
n
Pow
erA
C/D
C C
onverter
2ch
up to
30M
sps
Oscillo
scope
Bio
logical
Signal G
enerato
r
ECG
Cortex-M
4 M
CU
+5V
+12V
USB
CH
1CH
2
I2C
10ch ECG
Configuration and Name
Block Diagram
H A N B A C K E L E C T R O N I C S234
IT Convergence>>HBE-Healthcare LAB
ECG(Electrocardiogram)
Respiration
SpO2(Pulse Oximeter)
When the heart beats, the minute potential difference occurs in the myocardium.
The device measures it as electrodes attached to a living body surface and records the variation curve according to
time.
Respiratory measures the change in impedance due to changes in the internal volume of the chest.
Oxygen saturation (SpO2) is a percentage of the concentration of hemoglobin, which contains oxygen for the
concentration of total hemoglobin in the blood.
(Measuring the value to optical methods)
Measurement methods and interworking method
Electrode Site
Electrode Site
Electrode Site
ECG 1ch Measurement Module
Respiration Measurement Module
SpO2 Measurement Module
Result of Measurement
Result of Measurement
Result of Measurement
NIBP(Non-Invasive Blood Pressure)NIBP is a common way to measure blood pressure. You wind the cuff on the forearm. You put the air in the rubber cuff
using an air pump. It grows the volume of the cuff. After It prevents the arteries, It reduces the pressure in stages. and
then, It hear Sound that occurs when blood flow. It measures the systolic and diastolic blood pressure.
Cuff SiteNIBP Measurement Module
Result of Measurement
HBE-PC Base Control
IT Convergence
HBE-HealthCare LAB
H A N B A C K E L E C T R O N I C S 235
HANBACK ELECTRONICSw w w.hanback .com
Since 1984
HBE-HealthCare LAB
Bio Impedance
EEG(Electroencephalogram)
EMG(Electromyography)
The material Measured by impedance in components of the human body is water and fat. It measure body fat and body
water using bio-impedance.
The electric signal measured the electrical activity of the brain non-invasively by an electrode attached
to the head surface.
Attaching an electrode to the surface of the skin, It record the electric signal generated when muscle cells activate
electrically.
Bio Sensor Girp
Electrode Site
Electrode Site
Bio Impedance Measurement Module
EEG Measurement Module
EMG Measurement Module
Result of Measurement
Result of Measurement
Result of Measurement
GSR(Galvanic Skin Respones)It stimulates the sympathetic nervous system when you feel strong emotions and A lot of sweat is secreted from sweat
glands. it measure the conductivity of the skin by attaching the electrode to the two fingers.
Electrode SiteGSR Measurement Module
Result of Measurement
H A N B A C K E L E C T R O N I C S236
IT Convergence>>HBE-Healthcare LAB
Module Item Description
Embedded PC CPUExynos5422 CortexTM-A15 2GHz and
CortexTM-A7 Octa core CPU
Memory 2Gbyte LPDDR3
3D Accelerator Mali-T628 MP6
Display 7 inch 800x1280(WXGA)
Touch Screen 7 inch 10 point Capacitive Multi-Touch Screen
Storage eMMC 5.0 HS400 Flash Storage(8GByte)
USB USB 3.0 Host 2EA, USB 2.0 Host 1EA
HDMI HDMI 1.4a
Ethernet 10/100Mbps Ethernet with RJ-45
Wi-Fi (Option) USB Dongle
Bio-signal Monitoring System
Arduino Compatibility
SpO2 Measurement Module
NIBP Measurement Module
Bio Impedance Measurement Module
Respiration Measurement Module
GSR Measurement Module
ECG 1ch Measurement Module
EEG Measurement Module
EMG Measurement Module
HBE-ADK-2560 Module Connectivity Module Smart Device
+
ECG 10ch (Electrocardiogram)When the heart beats, the minute potential difference occurs in the myocardium.
The device measures it as electrodes attached to a living body surface and records the variation curve according to
time.
Electrode SiteECG 10ch Measurement Module
Result of Measurement
Specifications of Hardware
HBE-PC Base Control
IT Convergence
HBE-HealthCare LAB
H A N B A C K E L E C T R O N I C S 237
HANBACK ELECTRONICSw w w.hanback .com
Since 1984
HBE-HealthCare LAB
Module Item DescriptionMCU MCU ARM Cortex-M4 MCU+FPU, 210DMIPS
Memory 1MB Flash
Boot H/W Setting
Clock Speed Up to 168MHz
Debug SWD & JTAG
Reset H/W Reset
1ch ECG(Electrocardiogram) Channel Fixed 1ch RL Drive(3lead Patient cable)
Band width 0.1 ~ 50Hz
FilterHigh Pass Filter(0.1Hz), Low Pass Filter(50Hz), Notch Filter(60Hz)
Power Isolation Isolation DC/DC Mold Type
Data Isolation Analog Isolator
HR Measurable range 30 to 300BPM
HR Measurement accuracy ± 5% whichever is greater
EMG(Electronmyography) Channel Fixed 1ch RL Drive(3lead Patient cable)
Band width 10 ~ 500Hz
FilterHigh Pass Filter(10Hz), Low Pass Filter(496Hz), Notch Filter(60Hz)
Power Isolation Isolation DC/DC Mold Type
Data Isolation Analog Isolator
Measurable range 0.1 to 3.3V
HR Measurement accuracy ± 5% whichever is greater
EEG(Electroencephalogram) Channel Fixed 1ch RL Drive(3lead Patient cable)
Band width 0.1 ~ 50Hz
FilterHigh Pass Filter(0.1Hz), Low Pass Filter(50Hz), Notch Filter(60Hz)
Power Isolation Isolation DC/DC Mold Type
Data Isolation Analog Isolator
Measurable range 0.1 to 3.3V
Measurement accuracy ± 5% whichever is greater
NIBP (Non-Invasive Blood Pressure) Measurement method Oscillometric method
Measurement ItemsPulse RateSystolic pressureDiastolic pressure
Measurable rangePulse Rate: 40 ~ 200bpmSystolic pressure: 60 ~ 250mmHgDiastolic pressure: 40 ~ 200mmHg
Respiration Measurement method Impedance Pneumography
Measurable range 0, 3 to 120 breaths/min
Accuracy ±3breaths/min
Leads RA to LA
FilterHigh Pass Filter(0.05Hz), Low Pass Filter(150Hz), Notch Filter(Digital 160Hz)
Power Isolation Isolation DC/DC Mold Type
Data Isolation Analog Isolator
Bio-signal Monitoring System
H A N B A C K E L E C T R O N I C S238
IT Convergence>>HBE-Healthcare LAB
Module Item DescriptionSpO2(Pulse Oximeter) Pulse Measurable range 30 to 300BPM
Pulse Accuracy ±3BPM
SpO2 Measurable range 1 to 100%
SpO2 Accuracy 70 to 100% ±3Digits, 1 to 69% Unspecified
Filter High Pass Filter(0.05Hz), Low Pass Filter(150Hz), Notch Filter(Digital 160Hz)
Power Isolation Isolation DC/DC Mold Type
Data Isolation Analog Isolator
GSR (Galvanic Skin Respones)
Measurement method measures the electrical conductance between 2 points
Leads External Finger cots
Filter High Pass Filter(0.05Hz), Low Pass Filter(150Hz), Notch Filter(Digital 160Hz)
Power Isolation Isolation DC/DC Mold Type
Data Isolation Digital Isolator
Bio Impedance(body fat) Measurement method Tetrapolar Single (SF-BIA) and Multi-frequency (MF-BIA) BIA
Measurement Range 100~1KOhms
Measurement accuracy ±1%
Segmentation Single Segment
Frequency Single Frequency(>60KHz)
Current Single Current(<1mA)
Impedance calculation Multiple Interpolation
Power Isolation Isolation DC/DC Mold Type
Data Isolation Digital Isolator
10ch ECG Channel Fixed 1ch RL Drive(3lead Patient cable)
Band width 0.05 ~ 150Hz
Filter High Pass (0.05Hz), Low Pass Filter(Digital 150Hz), Notch Filter(Digital 60Hz)
Power Isolation Isolation DC/DC Mold Type
Data Isolation Digital Isolator
HR Measurable range 30 to 300BPM
HR Measurement accuracy ± 5% whichever is greater
Proto-Type MCU ARM Cortex-M4 MCU+FPU, 210DMIPS
Memory 1MB Flash
Boot H/W Setting
Clock Speed Up to 168MHz
Debug SWD & JTAG
Reset H/W Reset
Expansion I/O GPIO, UART, I2C, SPI, ADC, Power
Bread Board Terminal Strip 2EA, Bus Strip 1EA
Biological Signal Generator Display LCD
Button 7EA
Electrode 8EA
ECG Rate 80 BPM
amplitude 1mV
accuracy ± 5%
HBE-PC Base Control
IT Convergence
HBE-HealthCare LAB
H A N B A C K E L E C T R O N I C S 239
HANBACK ELECTRONICSw w w.hanback .com
Since 1984
HBE-HealthCare LAB
HBE-HealthCare LAB Main Body
ECG 10ch Measurement Cable
ST-LINK
NIBP Measurement Cuff
Bio Impedance Probe
Signal Measurement Cable
Oscilloscope Probe
Electronode
User Guide Book
USB Cable CD
SpO2 Measurement
Sensor and Cable
Power Cable
Module Item Description
Embedded PC (Bio-Signal
Measurement System)
Boot Loader U-boot 1.3.4
Operating System Linux Kernel 3.10.9
Platform Android kitkat 4.4.2
Display MIPI base display driver
Touch Screen Touch screen driver
Wi-Fi Wi-Fi driver, wpa-supplicant, iwconfig, libnetutils
Connection Manager GPIO, UART, I2C, SPI, ADC, Power
Network Server SSH Server, SFTP Server
USB USB gadget driver, USB accessory gadger
Ethernet Device Ethernet driver, ConnectionManager
AppECG, EMG, EEG, GSR, SpO2, Respiration, NIBP, Bio Impedance App
MCU (Cortex-M4)
1ch ECG ADC Driver
10ch ECG SPI Driver, Anti-aliasing filter, IIR filter, Nortch filter
EMG ADC Driver
EEG ADC Driver
GSR ACD Driver
SpO2 SPI Driver, FIR filter, IIR filter
Respiration I2C Driver, FIR filter
NIBP ADC Driver
Bio Impedance SPI Driver
Subject Contents
HBE-HealthCare-LAB
- Bio-signal theory
- Digital bio-signal measurement
- UART communication
- A/D converter
- Serial interface
- ECG theory and measurement
- ECG 10ch theory and measurement
- Respiration theory and measurement
- Pulse Oximeter theory and measurement
- NIBP theory and measurement
- Bio Impedance theory and measurement
- EEG theory and measurement
- EMG theory and measurement
- GSR theory and measurement
Product Configuration
Specifications of Software
Educational Contents
* This can be changed for Performance Improvement.