13
14,350 19,947 8,793 51,946 BUILDING SET BACK FROM CRADLE MT RD151,476 TWO WAY TWO WAY ONE WAY TWO WAY TWO WAY ONE WAY TWO WAY TWO WAY TWO WAY TWO WAY TWO WAY TWO WAY TWO WAY ONE WAY ONE WAY Car park layout 01 Car park layout 02 Car park layout 03 Car park layout 04 Car park layout 05 CRADLE MT RD i. a. b. c. e. f. f. h. j. j. n. k. l. m. m. m. CW.01 CW.03 f. IN.01. d. CW.02 BLD.02. BLD.03. BLD.01. m. m. m. o. EX.S k. k. g. p. 1.1 Site General a. Redirected main road. Redundant section of road dashed to be demolished & revegetated. b. Car-parking (approx 250 spaces incl. 10 equal access spaces) c. Large vehicle parking (35 spaces) plus overflow (300 spaces) d. Coach lay by / dropoff e. Visitor drop-off & disabled drop-off f. Service & emergency access, hardstand & TFS off-takes g. Petrol refuel lay-by - existing pumps to - existing pumps to be retained h. Staff parking (10 spaces) i. Shuttle bus parking (20 spaces) j. Coach parking (15 spaces) k. Landscaped open space l. Lookout & walkers track m. Future village expansion – Subject to separate development application. n. Bus wash down area, wall & bunded to prevent water run off o. Location of dump station p. Dotted line to indicate location of required water storage specified in the Servicing Report 1.0 General Notes 01. Refer to the individual building Floor Plans for envelop dimensions. 02. Refer to the Stormwater Management Plan and the Servicing Report for details of on-site was water management systems Appendix A & B. 03. Refer to Parking Layout Plans for parking arrangements, sizes and turning circle paths 04. Refer to Rendered Landscape Plan for all surfacing (incl. car park and access routes) and planting and plant species. 05. All infrastructure including telecommunications cable to be installed underground Site Ratio Roof area: 2770m2 / Site area 112,175m2. Site Coverage: 2.5% 01 Launceston, Hobart, Melbourne [email protected] http://www.cumulus.studio Cumulus Studio developing great ideas together CUMULUS STUDIO architecture & design Site Plan 0 20 50 N Rev F - 14.11.2017 Gateway Development Options Gateway Precinct Site Plan (DA)

Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

Site Plan_Precinct Plan

T16286-da08issuedrawing nº

8/06/2017original sizeprint date

drawing title

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWE

project

HobartLevel 8

copyright

03 66231 4841

Cumulus Studio Pty [email protected] 1, Hobart, 7000

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studio(plan)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

14,3

50

19,947

8,793

51,946

BUIL

DING

SET

BAC

K FR

OM C

RADL

E M

T RD

151,

476

TWO WAY

TWO WAY

ONE WAY

TWO WAY

TWO WAY

ONE

WAY

TWO WAY

TWO WAY

TWO W

AY

TWO

WAY

TWO WAY

TWO WAY

TWO

WAY

ONE

WAY

ONE

WAY

Car park layout 01

Car park layout 02

Car park layout 03

Car park layout 04

Car park layout 05

CRADLE MT RD

i.

a.

b.

c.

e.

f.f.

h.

j.

j.

n.

k. l.

m.m.m.

CW.01CW.03

f.

IN.01.

d.CW.02

BLD.02.

BLD.03.

BLD.01.m. m.

m.

o.

EX.S

k. k.

g.

p.

Site Plan_Propsed1:20001

1.1 Site Generala. Redirected main road. Redundant section of road dashed to be demolished & revegetated.b. Car-parking (approx 250 spaces incl. 10 equal access spaces)c. Large vehicle parking (35 spaces) plus overflow (300 spaces)d. Coach lay by / drop‑offe. Visitor drop-off & disabled drop-offf. Service & emergency access, hardstand & TFS off-takesg. Petrol refuel lay-by - existing pumps to - existing pumps to be retainedh. Staff parking (10 spaces)i. Shuttle bus parking (20 spaces)j. Coach parking (15 spaces)k. Landscaped open spacel. Lookout & walkers trackm. Future village expansion – Subject to separate development application.n. Bus wash down area, wall & bunded to prevent water run offo. Location of dump stationp. Dotted line to indicate location of required water storage specified in the Servicing Report

1.2 Gateway Precinct BuildingsCW.01 Covered Walkway & BBQ AreaCW.02 Covered Walkway & BBQ AreaBLD.01 Building 01BLD.02 Building 02BLD.03 Building 03VS Visitor Services BuildingEX.S Existing Shed to be retained

1.0 General Notes01. Refer to the individual building Floor Plans for envelop dimensions.02. Refer to the Stormwater Management Plan and the Servicing Report for details of on-site was

water management systems Appendix A & B.03. Refer to Parking Layout Plans for parking arrangements, sizes and turning circle paths04. Refer to Rendered Landscape Plan for all surfacing (incl. car park and access routes) and planting

and plant species.05. All infrastructure including telecommunications cable to be installed underground

Site RatioRoof area: 2770m2 / Site area 112,175m2.Site Coverage: 2.5%

01Launceston, Hobart, [email protected]://www.cumulus.studio

Cumulus Studio

developing great ideas together

CUMULUSSTUDIOarchitecture & design

Site Plan

0 20 50

NRev F - 14.11.2017Gateway Development OptionsGateway Precinct Site Plan (DA)

office
Text Box
BLD.04
Page 2: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

Cumulus StudioThe copyright for these designs, plans and specifications belongs to CumulusStudio Pty Ltd and must not be used, reproduced or copied without theirwritten permission.

Cumulus Studio

[email protected], Hobart, Melbourne

Cradle Mountain Master Plan - Staging Proposal

http://www.cumulus.studio

Master Plan | Staging Concept | November 2016

CRADLE MT RD i.

050 10 25

N

Gateway Precinct

05.

07.

06.

01. 02.

03.

06.

04.

Proceed with design, documentation and tender of Buildings 1 (as the Visitor Centre, Building 2 (tour operator spaces & cafe) & Building 7 (covered walkway)

Proposed Building Works

Future Building Works

Full Civil Works

01. Visitor Services Building02. TOFD Tenancies & Cafe03. Future - Kiosk04. Visitors Centre05. Landscaping06. Civil Works07. Walkway

Full Civil Works - New Carpark

Gateway Precinct Site Plan 1:1000

Page 3: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

06

Building 01Ground Floor

Building 01

T16286-da12issuedrawing nº

25/10/2017original sizeprint date

drawing title

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWE

project

HobartLevel 8

copyright

03 66231 4841

Cumulus Studio Pty [email protected] 1, Hobart, 7000

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studio(plan)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

Buiding 01GROUND FLOOR

Water TankTFS

Water Tank

Delivery

Outdoor area

F WCM WC

DDA WCAWC

AWC

General NoteRefer to Elevation Drawings for all external claddingmaterials.

Refer to Rendered Landscape Plan for alllandscape detail, planting and surfacing

Timber deck to all external undercover thresholds

TOFD PWS Office25m2 45m2

Waiting/Shop/Interp225m250m2

Toilets50m2

Undercover threshold

Building 01FIRST FLOOR

Void Tenancy below

PWS Open OfficeVoid

kitchen

PWS WC

PWS Change/Lockers

200m2

Building 01 Ground Floor Plan1:2001 Building 01 First Floor Plan

1:2002

Ground Floor Plan 1:200

Page 4: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

07

Building 01First Floor

Building 01

T16286-da12issuedrawing nº

25/10/2017original sizeprint date

drawing title

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWE

project

HobartLevel 8

copyright

03 66231 4841

Cumulus Studio Pty [email protected] 1, Hobart, 7000

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studio(plan)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

Buiding 01GROUND FLOOR

Water TankTFS

Water Tank

Delivery

Outdoor area

F WCM WC

DDA WCAWC

AWC

General NoteRefer to Elevation Drawings for all external claddingmaterials.

Refer to Rendered Landscape Plan for alllandscape detail, planting and surfacing

Timber deck to all external undercover thresholds

TOFD PWS Office25m2 45m2

Waiting/Shop/Interp225m250m2

Toilets50m2

Undercover threshold

Building 01FIRST FLOOR

Void Tenancy below

PWS Open OfficeVoid

kitchen

PWS WC

PWS Change/Lockers

200m2

Building 01 Ground Floor Plan1:2001 Building 01 First Floor Plan

1:2002

First Floor Plan 1:200

Page 5: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

Building 02

T16286-da14issuedrawing nº

24/11/2017original sizeprint date

drawing title

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWE

project

HobartLevel 8

copyright

03 66231 4841

Cumulus Studio Pty [email protected] 1, Hobart, 7000

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studio(plan)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

Slope 16º

RCL. 01Slope 40º

RCL. 01

RCL. 01

RCL. 01

Slope 13º

Building 02ROOF420m2

Building 02 Ground Floor Plan1:2001 Building 02 Roof Plan

1:2002

T16286-da13issuedrawing nº

8/06/2017original sizeprint date

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

project

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWEHobartLevel 8

copyright

Cumulus Studio Pty Ltdlevel 1, Hobart, [email protected] 66231 4841

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studiodrawing title

Building 01 Roof Plan(plan)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

Slope 5º

Slope 25º

RCL. 01

RCL. 01

Slope 30ºRCL. 01

Slope 51ºRCL. 01

TENANCY 01ROOF 410m2

Building 01 Roof Plan1:2001

Page 6: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

T16286-da24issuedrawing nº

8/06/2017original sizeprint date

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

project

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWEHobartLevel 8

copyright

Cumulus Studio Pty Ltdlevel 1, Hobart, [email protected] 66231 4841

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studiodrawing title

Building 01 Elevations(elevations)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

+874,815

+866,845

3,51

4

+869,845 8,52

3

extent of elevation.

natural timber cladding.

natural timber clad roofingat varying pitches withconcealed folded custommetal gutter

new ground line

sliding glazed doors natural ground line, dashed

maximum height abovenatural ground line

open to undercroft area

hinged glazed door

FG FG FG FG

RCL. 01

CL. 01 FG

Slope 25º

Slope 51º

extent of elevation.

4,94

3

screen door

screen to tanks

natural timber cladding

natural timber clad roofingat varying pitches withconcealed folded custommetal gutter

new ground line

natural ground line dashed

maximum height abovenatural ground line

RCL. 01

CL. 02

CL. 01Slope 25º

Slope 51º

+874,815

+869,845 6,746

maximum height abovenatural ground line

FG FG FG FG FG FG FG FG FG FG

FG

RCL. 01

CL. 02CL. 01+866,845

top hung window

timber clad roofing atvarying pitches with

concealed folded custommetal gutter

timber clad doorground line new

natural ground line, dashed

timber garage door, raw finish

timber cladding, raw finish

FGSlope 5º

4,65

8

maximum height abovenatural ground line

RCL. 01

CL. 01

natural timber cladding

natural timber clad roofingat varying pitches with

concealed folded custommetal gutter

ground line, new

natural ground line, dashed

Slope 30ºSlope 5º

Building 01 Elevation 011:2001 Building 01 Elevation 02

1:2002

Building 01 Elevation 031:2003 Building 01 Elevation 04

1:2004

CL. 01

CL. 02

RCL. 01

Timber board and batten cladding. Timber left unfinished.

90x45mm Timber battens on steel SHS frame180mmcentres. Timber left unfinished and frame to be finished inB64 Charcoal in accordance with the AS 2700 - 996.

Timber battens over sheet metal roof. Timber left unfinished.Timber cladding to match slope.

Material Note:All external materials other than natural stone,earth, timber or glass are finished in B64 Charcoaldefined in Australian Standard AS 2700 – 996,Colour Standards for General Purposes.

Page 7: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title
Page 8: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

08Cumulus StudioLaunceston, Hobart, [email protected]://www.cumulus.studio

developing great ideas together

CUMULUSSTUDIOarchitecture & design

Building 02Ground Floor

Gateway Development OptionsRev F - 14.11.2017

Ground Floor Plan 1:200

Building 02GROUND FLOOR420m2

Undercroft

Wat

er Ta

nkTF

S

Delivery

Tenancy 01 Tenancy 02 Tenancy 03 Tenancy 04

Kitchen

Dry Store

Cold Store

Servery

Order &Takeaway

Coffee & Bar

Airlock

DDA WC

Amb WC

Page 9: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

Building 02

T16286-da14issuedrawing nº

8/06/2017original sizeprint date

drawing title

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWE

project

HobartLevel 8

copyright

03 66231 4841

Cumulus Studio Pty [email protected] 1, Hobart, 7000

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studio(plan)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

Slope 16º

RCL. 01Slope 40º

RCL. 01Slope 40º

RCL. 01

RCL. 01

Slope 13º

TENANCY 02ROOF420m2

Building 02 Roof Plan1:2002

Page 10: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

Building 02 Elevations

T16286-da25issuedrawing nº

8/06/2017original sizeprint date

drawing title

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWE

project

HobartLevel 8

copyright

03 66231 4841

Cumulus Studio Pty [email protected] 1, Hobart, 7000

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studio(elevations)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

+873,990

+867,200

6,65

7

maximum height abovenatural ground line

natural timber clad roofingat varying pitches with

concealed folded custommetal gutter

natural timber cladding

natural ground line, dashedground line, new

RCL. 01

CL. 02

CL. 01

garage door

Slope 16º

maximum height abovenatural ground line

natural timber cladding

natural timber clad roofingat varying pitches with

concealed folded custommetal gutter

natural ground line, dashedground line, new

RCL. 01

CL. 01

fixed glazed window

Slope 13º

Slope 40º

+873,987

+867,200

7,17

4

20,439

maximum height abovenatural ground line

natural timber cladding

natural timber clad roofingat varying pitches with

concealed folded custommetal gutter

natural ground line, dashedground line, new

FG FG FG FG FG FG FG FG

RCL. 01

CL. 01

fixed glazed window

Slope 13º

Slope 40º

maximum height abovenatural ground line

natural timber clad roofingat varying pitches with

concealed folded custommetal gutter

natural ground line, dashedground line, new

natural timber cladding

RCL. 01

CL. 01

Slope 16ºSlope 40º

Building 02 Elevation 031:2003 Building 02 Elevation 04

1:2004

Building 02 Elevation 011:2001 Building 02 Elevation 02

1:2002

CL. 01

CL. 02

RCL. 01

Timber board and batten cladding. Timber left unfinished.

90x45mm Timber battens on steel SHS frame180mmcentres. Timber left unfinished and frame to be finished inB64 Charcoal in accordance with the AS 2700 - 996.

Timber battens over sheet metal roof. Timber left unfinished.Timber cladding to match slope.

Material Note:All external materials other than natural stone,earth, timber or glass are finished in B64 Charcoaldefined in Australian Standard AS 2700 – 996,Colour Standards for General Purposes.

Page 11: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

rev date purpose

#

CW.01 Plan

T16286-da20issuedrawing nº

8/06/2017

project:

DPIPWE

Tasmania, 7000Hobart

Cradle Mt Gateway

client:

original sizeprint date

drawing title

Level 8

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

copyright

03 66231 4841

Cumulus Studio Pty [email protected] 1, Hobart, 7000

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

(plan)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

CUMULUSSTUDIO

A3

Line of walkwaycanopy

line of road edge below

outline of roof edge

colour bond sheet roofingat minimal fall toconcealed edge guttercolour: charcoal

outline of roof edge

colour bond sheetroofing at minimal fall toconcealed edge guttercolour: charcoal

+867,520

+868,900

01

02

03

rubbish andrecycling bins

BBQ hotplates

BUILDING 05GROUND FLOORTavern & Bottleshop225m2

Retail 05.Bottleshop

Retail 05.Store

Retail 05.M WC

Retail 05.F WC

Retail 05.DDA WC

Water TankTFS

Water Tank

Water Tank

Undercroft

Store

Kiosk

ATM

Retail 05.Bar

Kiosk

BBQ AREA

TENANCY 03GROUND FLOOR100m2

Store

Line of walkwaycanopy

outline of walkway roofabove (shown dashed)structural columns

refer landscape plan forall surface treatment

line of road edge

refer landscape plan forall surface treatment

EX.SGROUND FLOOR220m2

structural columns

refer landscape plan for allsurface treatment

line of road edge

+867,065

Building 03GROUND FLOORKiosk & Stage110m2

CW.01GROUND FLOORWalkway & BBQ Area730m2

outline of future building

CW.01 Roof Plan1:5002

CW.01 Ground Floor Plan1:5001

Page 12: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

CW Elevations

T16286-da29issuedrawing nº

8/06/2017original sizeprint date

drawing title

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWE

project

HobartLevel 8

copyright

03 66231 4841

Cumulus Studio Pty [email protected] 1, Hobart, 7000

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studio(elevations)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

868,392

871,253

3,30

0

2,86

0colour bond sheet roof withconcealed gutter edge

all steel columns and framingto have paint finish, colourB64 Charcoal

natural ground line, dashedground line, new

timber BBQ bench with SS benchtop.

3,60

0

871,253

867,653

all steel columns and framingto have paint finish, colourB64 Charcoal

colour bond sheet roof withconcealed gutter edge

natural ground line, dashedground line, new

871,253

868,388

2,86

5

all steel columns and framingto have paint finish, colourB64 Charcoal

colour bond sheet roof withconcealed gutter edge

natural ground line, dashedground line, new

866,117

869,484

3,36

7

natural ground lineground line

steel columns, painted finishcolour: charcoal

colour bond sheet roofingwith concealed edge guttercolour: charcoal

timber bbq bench withstainless steel top

CW.01 Elevation 011:2001

CW.01 Elevation 021:2002

CW.01 Elevation 031:2003

CW.02 Elevation1:2004

Page 13: Ground Floor - Parliament of Tasmania · 2017-11-29 · 06 Building 01 Ground Floor. Building 01 T16286-da12. drawing nº issue. 25/10/2017. print date original size drawing title

CW Elevations

T16286-da30issuedrawing nº

8/06/2017original sizeprint date

drawing title

Peter Walker, CC2143E

Concept Designreason of issue

EW, EPdrawn by

PWchecked by

accredited designer:

Cradle Mt Gateway

client

Tasmania, 7000

DPIPWE

project

HobartLevel 8

copyright

03 66231 4841

Cumulus Studio Pty [email protected] 1, Hobart, 7000

The copyright for these designs, plans and specificationsbelongs to Cumulus Studio Pty Ltd and must not be used,reproduced or copied without their written permission.

Cumulus Studio(elevations)

general notesThese drawings show design intent & are suitable as a guideonly. Do not scale off the drawings. All dimensions inmillimetres. Dimensions of existing building are indicative only -they should not be relied on and are to be verified on sitebefore commencing work. All documents shall be read inconjunction with specifications and any consultants detail. Allwork shall be in accordance with the Building Code ofAustralia, relevant Australian Standards & local authority by-laws and regulations. Any discrepancies, errors or omissionsshall be referred to the Architects. Drawings are not to be usedfor construction until issued Construction

rev date purpose rev date purpose

DA

A3

867,019

869,852

2,83

4

steel columns, painted finishcolour: charcoal

colour bond sheet roofingwith concealed edge guttercolour: charcoal

869,529

866,043

3,48

7

all steel columns and framingto have paint finish, colourB64 Charcoal

colour bond sheet roof withconcealed gutter edge

natural ground line, dashedground line, new

timber BBQ bench with SS benchtop.

IN.01 Elevation1:2002

CW.03 Evlevation1:2001