HUAWEI TECHNOLOGIES CO., LTD. Page 1Huawei Confidential
Introduction to the Mapping Between CPRI Ports and Slots on the GSM 3900 Series Base Station
Introduction to the Mapping Between CPRI Ports and Slots on the GSM 3900 Series Base Station
Wireless Product Service DepartmentWireless Product Service Department
For internal use only
HUAWEI TECHNOLOGIES CO., LTD. Page 2Huawei Confidential
Background and Application Principle
Background The layout of the CPRI RF cable connection to the GRFU/DRFU slots is usually complex for field engineers.
To reduce the complexity, this material introduces a mapping principle between CRPI ports and slots to
satisfy the requirements of various scenarios. Used together with the GRFU/DRFU configuration principle
and slot planning principle, the application of this principle implements a comparatively fixed mapping
between the CPRI ports and the cell partition for future capacity expansion and maintenance. In addition,
a graphical configuration tool is developed to quickly output the configuration and connection diagram
for on-site project delivery.
HUAWEI TECHNOLOGIES CO., LTD. Page 3Huawei Confidential
Mapping Principle of the CPRI Ports - Single Cabinet
Mapping between CPRI ports
and slots:
Ports CPRI 0 to 5 on the GTMU
correspond to slots 0 to 5
where the
GRFUs/DRFUs are installed.
The CPRI port that corresponds
to an
empty slot need not be
connected. Mapping between cells and
slots in single-cabinet
configuration mode:
Slots 0 and 1 correspond to
Cell 1.
Slots 2 and 3 correspond to
Cell 2.
Slots 4 and 5 correspond to
Cell 3.
Single Cabinet
cell1 cell2 cell3
HUAWEI TECHNOLOGIES CO., LTD. Page 4Huawei Confidential
Mapping Principle of the CPRI Ports - Two Cabinets
Mapping between CPRI ports and
slots:
Ports CPRI 0, 2, and 4 on the GTMU
correspond to slots 0, 2, and 4
where
the GRFUs/DRFUs are installed in
cabinet 0.
Ports CPRI 1, 3, and 5 on the GTMU
correspond to slots 0, 2, and 4
where
the GRFUs/DRFUs are installed in
cabinet 1.
Mapping between cells and slots in
double-cabinet configuration mode:
Slots 0 and 1 correspond to Cell 1.
Slots 2 and 3 correspond to Cell 2.
Slots 4 and 5 correspond to Cell 3.
Two Cabinets
cell1 cell2 cell3
HUAWEI TECHNOLOGIES CO., LTD. Page 5Huawei Confidential
Mapping Principle of the CPRI Ports - Three Cabinets
Mapping between CPRI ports and slots:
Ports CPRI 0 and 1 are connected to
the
first cabinet.
Ports CPRI 2 and 3 are connected to
the
second cabinet.
Ports CPRI 4 and 5 are connected to
the
third cabinet.
The CPRI ports are connected to
slots 0
and 3 where the GRFUs/DRFUs are
installed in the cabinet that the
ports
correspond to. Other GRFUs/DRFUs
are
cascaded in order. Mapping between cells and slots in three-
cabinet configuration mode:
One cabinet corresponds to one cell.
…Three Cabinets
cell1 cell3
cell2
HUAWEI TECHNOLOGIES CO., LTD. Page 6Huawei Confidential
Benefit I Used together with the cell planning principle, the application of this
principle implements comparatively fixed cell partition
corresponding to the CPRI ports, thus implementing a clear cell
partition and simple data configuration. The recommended partition
of three cells is shown as follows:
Cell partition in a single cabinet
Cell partition in two cabinets
HUAWEI TECHNOLOGIES CO., LTD. Page 7Huawei Confidential
Benefit I
Cell partition in three cabinets
HUAWEI TECHNOLOGIES CO., LTD. Page 8Huawei Confidential
Benefit II Star interconnection can be applied to the CPRI ports on all the modules so that
great change for the feeder connection is avoided during the capacity expansion. In a typical capacity expansion scenario, the configuration data is modified and the
services are not disrupted even if the CPRI networking mode is changed.
Reserve a slot for capacity expansion.
The corresponding port is also reserved.
HUAWEI TECHNOLOGIES CO., LTD. Page 9Huawei Confidential Huawei Technologies | 9
Benefit III
Meeting Huawei requirements on delivery with boards and cable connections
Unifying the configuration principle globally
Tool Advantages
Standardizing on-site configuration and connection operation
Outputting MML scripts after being integrated to the CME in later versions
A useful tool is used to facilitate and standardize operations.
HUAWEI TECHNOLOGIES CO., LTD. Page 10Huawei Confidential Huawei Technologies | 10
Benefit IV Unified Procedures
Complies with the policy of delivery with boards and cabling requirements. Field engineers need not
install modules and connect cables so that the working hour of on-site installation is reduced. Thus,
the service cost reduces. The tool is used, thus facilitating the data configuration and ensuring the consistency between the
data configuration and the hardware installation. Accurately locates the slot where the faulty board is located, thus increasing the success rate of
remote problem location. Implements smooth upgrade and applies globally standardized data configuration to guarantees the
upgrade.
InstallationDelivery Configuration Commissioning Upgrade
1 2 3 4 5
HUAWEI TECHNOLOGIES CO., LTD. Page 11Huawei Confidential Huawei Technologies | 11
Benefit V Consistent principle, applied to different products and the same
product of different versions, complies with the evolution trend of
smooth capacity expansion of the network.
GBTS8.1
DBS&BTS3900 V300R008C11
GBTS9.0
DBS&BTS3900 V300R009C00
SRANBTS
DBS&BTS3900 V100R002C00
Thank you
www.huawei.com