Greensboro, North Carolina Product OverviewOverhead Distribution Cutouts, Overhead DisconnectSwitches and Capacitor Fuses
greensboro overview.qxp 1/5/2005 11:56 AM Page 1
- 2 - - 3 -
Overhead Distribution Cutouts
Product Description Application Options
ICX
• Distribution cutout for use onoverhead distribution system toprovide overcurrent protection
• Fuse tube interchangeable withS&C Type XS, Cooper Type L,and AB Chance Type C cutouts
• 15 kV – 38 kV, up to 16 kA
• Provides visible indication offuse operation and a visiblebreak sectionalizing point formaintenance personnel
• Can function as a loadbreakswitch when used in conjunctionwith a portable loadbreak tool
• Silicone rubber insulator (110 -180 kV BIL) or polymer con-crete insulator (110 & 125 kVBIL)
• Stainless steel seacoast design
• Cutout/arrester combination
• Emission Control Device (ECD)
LBU
• Outdoor loadbreak switch thatcan be used as a fused cutoutfor distribution systems
• Loadbreak interruption isaccomplished by means of aself contained loadbreak arcchute which confines the arcand provides a deionizing action
• 15 kV – 27 kV, up to 16 kA
• Provides overcurrent protectionfor capacitor banks and givesvisible indication that the equip-ment is energized
• Used for switching the magnetiz-ing currents of single and three-phase transformer banks and toswitch capacitive currents asso-ciated with underground feedercable at the riser pole
• Silicone rubber insulator (110 -180 kV BIL) or polymer con-crete insulator (110 & 125 kVBIL)
• Cutout/arrester combination
• ECD
NCX
• Distribution cutout for overcur-rent protection on overhead dis-tribution systems
• 15 kV – 38 kV, up to 20 kA
• Provides visible indication offuse operation and a visiblebreak sectionalizing point formaintenance personnel
• Can function as a loadbreakswitch when used in conjunctionwith a portable loadbreak tool
• Polymer concrete insulator(110 & 125 kV BIL)
• Cutout/arrester combination
EU
• Enclosed cutouts in porcelain housing
• Designed for either dropout ornon-dropout operation
• For outdoor use only
• Used in replacement applica-tions in close spaces wherethere are increased safetyneeds
N/A
Overhead Disconnect Switches
Product Description Application Options
SID
• Single insulator disconnect witha double blade door and two 2-hole extended NEMA pad termi-nals
• 15 kV – 38 kV, 600 or 900 Acontinuous loads with a 40 kAmomentary rating
• Single-phase disconnect onoverhead distribution feedersand in outdoor distribution sub-stations.
• Can be mounted like a standardcutout: underhung, mounteddirectly on a pole for use as adisconnect between overheadand underground lines, or as avisible disconnect for mainte-nance of line equipment
• Polymer concrete insulator(110 & 125 kV BIL)
• Optional mounting kit allowsthe following mounting scenar-ios: single or double crossarmunderhung, directly on a pole,directly on a pole vertically,and crossarm vertically
LSID
• Loadbreak single insulator dis-connect with self-containedloadbreak capabilities, a doubleblade door, and two 2-holeNEMA pad terminals
• 15.5 kV – 15/27 kV, 600 A con-tinuous and loadbreak
• Single-phase disconnect onoverhead distribution feedersand in outdoor distribution sub-stations
• Self-contained loadbreakenables lineman to interrupt loadcurrent with a hookstick
• Can be mounted underhung likea standard cutout or mounteddirectly on a pole used as a dis-connect between overhead andunderground lines
• Polymer concrete insulator(110 & 125 kV BIL)
• Optional mounting kit allowsthe following mounting scenar-ios: single or double crossarmunderhung, directly on a pole,directly on a pole vertically,and crossarm vertically
DCD
• Double insulator single-phasedisconnect switch
• Rated at 600 or 900 A, availablein nominal ratings of 14.4 kV(110 BIL) or 25 kV (125 BIL)
• Hookstick operated switch usedfor sectionalizing or isolatingequipment on electrical distribu-tion systems up to 38 kV
• Can be mounted vertical orunderhung, or on a single ordouble crossarm
• Insulators available in 2.25”bolt circle porcelain or epoxy
• Bypass studs available forbypassing reclosers, voltageregulators, capacitor banks, ormetering devices
RBD
• Single-phase bypass disconnectswitch
• Rated at 600 or 900 A, availablein nominal ratings of 14.4 kV(110 BIL) or 25 kV (125 BIL)
• Provides a means for bypassingand disconnecting reclosers orvoltage regulators, allowingmaintenance on equipment with-out service interruption
• Can be mounted in the followingconfigurations: vertical or under-hung, pole-mounted, or single ordouble crossarm
• Insulators available in 2.25”bolt circle porcelain or epoxy
• Mounting options: back bracketfor vertical or underhung, 30-degree pole-mount bracket, orpackage of three switches pre-mounted on crossarm
ITD
• Single-phase, non-loadbreak,inline tension disconnect switchwith silicone insulator
• Maximum voltage ratings: 15 kV(150 BIL) or 27 kV (150 BIL)
• Continuous current rating of 600or 900 A
• Used for manual switching ofde-energized or parallel circuitsof overhead distribution linesrated 15-38 kV
• Loadbreak hooks allow for oper-ation with a portable loadbustertool
N/A
greensboro overview.qxp 1/5/2005 11:57 AM Page 2
- 2 - - 3 -
Overhead Distribution Cutouts
Product Description Application Options
ICX
• Distribution cutout for use onoverhead distribution system toprovide overcurrent protection
• Fuse tube interchangeable withS&C Type XS, Cooper Type L,and AB Chance Type C cutouts
• 15 kV – 38 kV, up to 16 kA
• Provides visible indication offuse operation and a visiblebreak sectionalizing point formaintenance personnel
• Can function as a loadbreakswitch when used in conjunctionwith a portable loadbreak tool
• Silicone rubber insulator (110 -180 kV BIL) or polymer con-crete insulator (110 & 125 kVBIL)
• Stainless steel seacoast design
• Cutout/arrester combination
• Emission Control Device (ECD)
LBU
• Outdoor loadbreak switch thatcan be used as a fused cutoutfor distribution systems
• Loadbreak interruption isaccomplished by means of aself contained loadbreak arcchute which confines the arcand provides a deionizing action
• 15 kV – 27 kV, up to 16 kA
• Provides overcurrent protectionfor capacitor banks and givesvisible indication that the equip-ment is energized
• Used for switching the magnetiz-ing currents of single and three-phase transformer banks and toswitch capacitive currents asso-ciated with underground feedercable at the riser pole
• Silicone rubber insulator (110 -180 kV BIL) or polymer con-crete insulator (110 & 125 kVBIL)
• Cutout/arrester combination
• ECD
NCX
• Distribution cutout for overcur-rent protection on overhead dis-tribution systems
• 15 kV – 38 kV, up to 20 kA
• Provides visible indication offuse operation and a visiblebreak sectionalizing point formaintenance personnel
• Can function as a loadbreakswitch when used in conjunctionwith a portable loadbreak tool
• Polymer concrete insulator(110 & 125 kV BIL)
• Cutout/arrester combination
EU
• Enclosed cutouts in porcelain housing
• Designed for either dropout ornon-dropout operation
• For outdoor use only
• Used in replacement applica-tions in close spaces wherethere are increased safetyneeds
N/A
Overhead Disconnect Switches
Product Description Application Options
SID
• Single insulator disconnect witha double blade door and two 2-hole extended NEMA pad termi-nals
• 15 kV – 38 kV, 600 or 900 Acontinuous loads with a 40 kAmomentary rating
• Single-phase disconnect onoverhead distribution feedersand in outdoor distribution sub-stations.
• Can be mounted like a standardcutout: underhung, mounteddirectly on a pole for use as adisconnect between overheadand underground lines, or as avisible disconnect for mainte-nance of line equipment
• Polymer concrete insulator(110 & 125 kV BIL)
• Optional mounting kit allowsthe following mounting scenar-ios: single or double crossarmunderhung, directly on a pole,directly on a pole vertically,and crossarm vertically
LSID
• Loadbreak single insulator dis-connect with self-containedloadbreak capabilities, a doubleblade door, and two 2-holeNEMA pad terminals
• 15.5 kV – 15/27 kV, 600 A con-tinuous and loadbreak
• Single-phase disconnect onoverhead distribution feedersand in outdoor distribution sub-stations
• Self-contained loadbreakenables lineman to interrupt loadcurrent with a hookstick
• Can be mounted underhung likea standard cutout or mounteddirectly on a pole used as a dis-connect between overhead andunderground lines
• Polymer concrete insulator(110 & 125 kV BIL)
• Optional mounting kit allowsthe following mounting scenar-ios: single or double crossarmunderhung, directly on a pole,directly on a pole vertically,and crossarm vertically
DCD
• Double insulator single-phasedisconnect switch
• Rated at 600 or 900 A, availablein nominal ratings of 14.4 kV(110 BIL) or 25 kV (125 BIL)
• Hookstick operated switch usedfor sectionalizing or isolatingequipment on electrical distribu-tion systems up to 38 kV
• Can be mounted vertical orunderhung, or on a single ordouble crossarm
• Insulators available in 2.25”bolt circle porcelain or epoxy
• Bypass studs available forbypassing reclosers, voltageregulators, capacitor banks, ormetering devices
RBD
• Single-phase bypass disconnectswitch
• Rated at 600 or 900 A, availablein nominal ratings of 14.4 kV(110 BIL) or 25 kV (125 BIL)
• Provides a means for bypassingand disconnecting reclosers orvoltage regulators, allowingmaintenance on equipment with-out service interruption
• Can be mounted in the followingconfigurations: vertical or under-hung, pole-mounted, or single ordouble crossarm
• Insulators available in 2.25”bolt circle porcelain or epoxy
• Mounting options: back bracketfor vertical or underhung, 30-degree pole-mount bracket, orpackage of three switches pre-mounted on crossarm
ITD
• Single-phase, non-loadbreak,inline tension disconnect switchwith silicone insulator
• Maximum voltage ratings: 15 kV(150 BIL) or 27 kV (150 BIL)
• Continuous current rating of 600or 900 A
• Used for manual switching ofde-energized or parallel circuitsof overhead distribution linesrated 15-38 kV
• Loadbreak hooks allow for oper-ation with a portable loadbustertool
N/A
greensboro overview.qxp 1/5/2005 11:57 AM Page 2
1VAG
0001
-DB
Rev
. A O
ctob
er 2
004
© C
opyr
ight
200
4 AB
B. A
ll rig
hts
rese
rved
.
ABB Inc.406 Banner AvenueGreensboro, NC 27401Tel: +1-252-827-3212www.abb.com/mediumvoltage
Capacitor Fuses
Indoor
CLN
• 600 V Current Limiting
• Continuous amperes: 25, 50, 75, 100, 125, 150, 175, 200, 225
• Primary application is individual unit fusing of low voltage single and three phase capacitors in metalenclosed equipment
CLC
• 1.2-4.3 kV Current Limiting
• The 1200, 1800 and 3000 volt ratings are current limiting, indicating and non disconnecting
• The 2500 volt and 4.3/2.5 kV ratings are current limiting, non-indicating and non-disconnecting
• Primary application is individual unit fusing of low voltage single and three phase capacitors in metalenclosed equipment
CIL
• 5.5-15.5 kV Current Limiting & Expulsion
• Two part design:- the high current section interrupts high 60Hz fault currents and/or high frequency discharge current
from parallel capacitors- the low voltage sections consist of a standard NEMA type K fuse link mounted in a fiber tube
Outdoor
CXP
• 9.7-26.2 kV Expulsion
• Primary application is individual capacitor unit fusing in outdoor capacitor equipment
• Applications: in all ungrounded wye applications, in all grounded wye applications when the capacitorunits are connected in two or more series group
COL
• 2.8-23 kV Current Limiting & Expulsion
• Two part design:- the high current section interrupts high 60Hz fault currents and/or high frequency discharge current
from parallel capacitors- the low voltage sections consists of a standard NEMA type K fuse link mounted in a fiber tube
CLXP
• 2.5-25 kV Current Limiting & Expulsion
• A very high energy capability individual capacitor fuse used in outdoor banks with many parallelcapacitor units