4
Greenhouse Gas Emissions Monitoring Solutions for regulatory compliance and simplified calculation

Greenhouse Gas Emissions Monitoring - Emerson Electric · 2018. 12. 26. · MC-001697 Rev A 04/2013 EMERSON WORLD-LEADING FLOW AND DENSITY technology SETS THE STANDARD FOR RELIABLE,

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Greenhouse Gas Emissions Monitoring - Emerson Electric · 2018. 12. 26. · MC-001697 Rev A 04/2013 EMERSON WORLD-LEADING FLOW AND DENSITY technology SETS THE STANDARD FOR RELIABLE,

Greenhouse Gas Emissions Monitoring Solutions for regulatory compliance and simplified calculation

Page 2: Greenhouse Gas Emissions Monitoring - Emerson Electric · 2018. 12. 26. · MC-001697 Rev A 04/2013 EMERSON WORLD-LEADING FLOW AND DENSITY technology SETS THE STANDARD FOR RELIABLE,

11,000+ Installations are covered by the EU Emissions Trading Scheme covering almost every industry served by Emerson. The gain in efficiency, time and cost of ownership due to usage of Micro Motion and Rosemount technologies is further amplified with the emission regulations. Industry experts around the region, looking for an effective solution are further increasing their reliance on Emerson.

“EU Emissions regulation is adding work-time and cost while work

force is shrinking and international competition is intensifying”

What if you could.....

Ensure compliance to the EU Emissions regulation & simultaneously improve plant efficiency• Measure mass flow directly, with highest possible repeatability, turndown and

accuracy

• Direct mass measurement of gas enables better control of your air/fuel ratio, optimizes fuel gas usage, and reduces fuel waste

• Measure real-time energy content of gas with specific gravity to improve combustion efficiency and reduce fuel consumption for varying gas composition

• Achieve mass balance in your plant and ensure optimized production, improved throughput and reduced waste

• ISO 17025 accredited flow calibration laboratory to meet regulatory requirements

Improve manufacturing flexibility• A single meter handles measurement of multiple products and recipes without

recalibration reducing the number of equipment and piping required

• Meter is equipped with density measurement to indicate the exact fluid switch over time when handling multiple fluids

• Eliminate pressure and temperature compensation and achieve direct mass measurement to improve process control and flexibility in manufacturing

• Detect rapid gas composition changes with specific gravity meter

Improve plant safety while reducing regulation-driven maintenance, downtime & operations costs

• Almost no maintenance throughout the life time of the meter

• Smart Meter Verification for Micro Motion Coriolis meters drastically reduces meter verification time and alerts the operator of any meter damage; thus providing the easiest way to comply with the regulatory requirement around checking the meter'shealth

• Smart Meter Verification with host-based software can help document audit trails and produce reports that can be used for audit purposes

• Critical alarms alert you to abnormal process conditions so you can address process upsets early

• Eliminate up to 90% of potential leak points compared to installing a traditional orifice run

• Known Density Verification method for gas density and specific gravity for detection of corrosion, erosion or coating

Page 3: Greenhouse Gas Emissions Monitoring - Emerson Electric · 2018. 12. 26. · MC-001697 Rev A 04/2013 EMERSON WORLD-LEADING FLOW AND DENSITY technology SETS THE STANDARD FOR RELIABLE,

Custody Transfer / Check Metering / Allocation

• Gain confidence knowing you are getting what you are paying for

• Accurately measure “mass-in” to avoid over-stating or under stating of calculated emissions

Combustion Control

• Minimize the effect of variations in fuel

• Improve ability to control air to fuel ratio and operate more efficiently

• Reduce No through improved combustion control

• Reduce potential safety hazards associated with excess fuel

Mass Balance Diagram

• Provide best possible input to your controller for reactor / process control

• Achieve highest throughput while also maintaining desired quality

• Reduce waste and rework

x

Fuel Gas / Natural Gas

Furnaces

Boilers

Dryers, Incinerators, Turbines, etc.

Steam

Fuel Gas

Air

Process Unit A

Process Unit B

Process Unit C

Mass In

Mass Out

Ethylene

Comonomer

Hydrogen

Catalyst

DiluentRecycle

Pre-polymerisationReactor

Loop Reactor Gas

Flash

Polymer

Gas PhaseReactor

PolymerDegassingPelletising

Polyethelene

Source: Borstar Process

Page 4: Greenhouse Gas Emissions Monitoring - Emerson Electric · 2018. 12. 26. · MC-001697 Rev A 04/2013 EMERSON WORLD-LEADING FLOW AND DENSITY technology SETS THE STANDARD FOR RELIABLE,

MC-001697 Rev A 04/2013

EMERSON WORLD-LEADING

FLOW AND DENSITY

technology

SETS THE STANDARD FOR

RELIABLE, REPEATABLE,

HIGH PERFORMANCE

MEASUREMENT

Emerson’s Micro Motion devices are known globally in over 85 countries for quality, reliability, and application expertise.

For a complete list of contact information and websites, please visit: www.emersonprocess.com/home/contacts/global

Emerson Process Management Americas 7070 Winchester Circle Boulder, Colorado USA 80301

T: 800 522 6277T: +1 (303) 527 5200F: +1 (303) 530 8459

www.MicroMotion.com www.Rosemount.com

Mexico T: 52 55 5809 5300 Argentina T: 54 11 4837 7000 Brazil T: 55 15 3413 8000 Venezuela T: 58 26 1300 8100

Emerson Process Management Europe/Middle EastCentral & Eastern Europe T: +41 41 7686 111 Dubai T: +971 4 811 8100Abu Dhabi T: +971 2 697 2000 France T: 0800 917 901 Germany T: 0800 182 5347Italy T: 8008 77334The Netherlands T: +31 318 495 555Belgium T: +32 2 716 77 11 Spain T: +34 913 586 000 U.K. T: 0870 240 1978 Russia/CIS T: +7 495 981 9811

Emerson Process Management Asia Pacific Australia T: (61) 3 9721 0200 China T: (86) 21 2892 9000 India T: (91) 22 6662 0566 Japan T: (81) 3 5769 6803South Korea T: (82) 2 3438 4600 Singapore T: (65) 6 777 8211

©2013 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. DeltaV is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners.

Ideal For Benefits

• Routine verification checks • Improved availability, quality, safety, health and environment

• Performance checks for custody transfer field proving for regulatory reporting

• No interruption of process measurement, no operator exposure

• Troubleshooting to isolate problems and eliminate flow measurement suspicions

• No special technical training requirements

• Safety checks to determine actual tube structural integrity • Completes in 90 seconds

• Tracking erosion or corrosion when it is expected as part of the process

• Tracks configuration against last verified configuration

• Quality check to support required procedures • Tracks zero against last verified and factory zero and span

Micro Motion Smart Meter Verification