  • 1. INSTALLATION OPTIONS Available in seven models, the Canplas Endura Grease Interceptor should beinstalled as close as possible to the appliances it serves, ensuring that on-going Typical On Floor VENTEDWASTE maintenance and accessibility of the unit is fully considered and accommodated. VENTED The following illustration WASTE VENTED represents a typical system designWASTETANK DIMENSIONS commonly found in food preparation facilities. If installed (304 mm)15 - 20GPM25 GPM 35GPM50GPM under a sink, ensure there is 12 (304 mm) clearance (18 for 50 GPM models)(304 mm)A 23.623.6 31 31 to remove the baffles for cleaning B 17.517.523.5 23.5 and maintenance. If this is not practical, Semi-recessing the tank C3.54.15 5 is a viable alternative. *D 12.812.212.5 18.5E 16.316.317.5 23.5 Typical In Floor (Recessed) When installing in a new floor, the B FLOW CONTROL DIMENSIONSFLOW AIR INTAKE TEE interceptor, with lid secured, must CONTROLbe filled with water to provide FlowControl AirIntakeTee FLOWAIR INTAKE TEE CONTROL extra weight to ensure the unit Dim. 232 3 does not move when the floor isEbeing poured. Hand tamp only. A 3.0 4.23 2.91 2.67C Extensions are available for all B3.845.93 2.714.01 models including the flow control device. Provision of a concrete pit A C- - 2.24 2.27D with a metal access cover will be(7.6 m) (7.6 m) required where pump trucks or(7.6 m) fork lifts travel. Note:Theuseoftheflowcontroldeviceisessentialforallinstallations. *Diffuserbaffleonlyusedin35and50GPMmodelsVENTEDWASTE VENTED WASTE CAPACITIESVENTED Typical Multi-StoryWASTE 15GPM20GPM 25GPM 35GPM 50GPM One interceptor serving multiplePartNumber3915A023920A02 3925A03 3935A03 3950A03 fixtures is recommended only3935A04 3950A04 when the fixtures are located close GreaseCapacity(lbs.)actual65 7074115122 together. In such installations, each fixture should be individually OperatingTemp.Capabilities220 F220 F 220 F 220 F 220 F trapped and back-vented. If the first story is raised more than 8 SurfaceLoadCapacity 440 lb440 lb 440 lb 440 lb 440 lb feet, a secondary flow controlUnitsWeightCapacity(EMPTY)23 lb 23 lb23 lb 45 lb 60 lb must be installed preceding the grease interceptor to maintainLiquidCapacity21.6 gallons21.6 gallons21.6 gallons39.4 gallons 52.0 gallons flow velocities in the system.ConnectionSize(Mechanical) 22 33 (03)3 (03)VENTEDWASTE VENTED4 (04)4 (04) WASTEVENTEDWASTE INTERCEPTOR SIZING Correct sizing of your grease interceptor is important. To assist in accurate calculation visit www.endurainterceptor.comCUSTOMER FEEDBACKand use our Endura Quick Size tool to confirm the correct capacity and model number required for your application.I hate wasting money. Our restaurants had metal units installed in the floor. Between the corrosive soils, salts and grease, we were replacing baffles and tanks every few years. The Endura saves money, hassle and best of all is odor free. -GaryTremblay,BostonPizza(7.6 m) We were spending $18,000 per year getting our drains flushed. Grease build up in our For additional technical, engineering, code approvals, installation guidelines and operating instructions, please contact us(7.6 m)manholes was typically 8 to 10 inches. Since the Endura was installed, these problems have at the numbers below or visit www.canplasplumbing.com (7.6 m)gone away. -SimonLabadie,McDonaldsRestaurant,Levis,QCCanplasIndustriesLtd.CanplasLLC TECHNICALASSISTANCE Our local California sewer authority recommended the Endura. The design andP.O. Box 1800, 500 Veterans Drive11402 East 53rd Ave.Barrie, ONBarrie, OntarioSuite 200, Denver, CO Tel: (888) 461-1771 longevity makes it the best unit on the market. -PaulLachut,Pro-TechPlumbingCanada L4M 4V3 U.S.A. 80239 (705) 726-3361Tel: (705) 726-3361Tel: (303) 373-1918 Fax: (705) 726-2186 Being easy to warehouse, I always have one of each size on the shelf. Using couriers or parcelToll Free: 1-800-461-5300Toll Free: 1-888-461-5307 Email: technical@canplas.com post, I can ship to any customer in the country. -AlElliott,WolseleyPlumbingGroupFax: (705) 726-2186Fax: (303) 373-1923Website: www.canplasplumbing.com Website: www.canplasplumbing.comEmail: plumbing@canplas.comEmail: denver.sales@canplas.com Being 1/3 the weight of metal units, the Endura is easy to transport and install. It is so light, I VENTED can install it by myself and cut my install costs in half. -MarcBenoit,PlumtechPlumbing WASTEVENTEDWASTE VENTED WASTE39-EN-0107

2. - The engineered solution to grease managementPatented Baffle SystemImproved SeparationManufactured in engineered thermoplastic, the functionality of the uniquely designed baffling system cannot beThermoplastic construction provides the Endura with superior thermal properties resulting in enhanced greasecompromised by corrosion. The inlet baffle was specifically designed to slow the inlet flow and mix the entrained separation. The patented baffle and influent ramp design creates superior grease separation and retention.air, introduced by the flow control assembly, to enhance grease separation. The result is a separation efficiency ofbetween 93% and 97% (PDI test certification)Versatile ConnectionsUsing standard mechanical connectors, the Endura can be integrated to existing plumbing systems regardless of In the food service industry today, increasing focus is being placed on the individual and corporate commercial food service Airtight Seal to Contain Offensive Odorspiping material. establishment from city, municipality, provincial and state authorities, to deal effectively with the significant problems presented by the discharge of grease into the drainage and sewer system.The premium silicone foam gasket provides an airtight seal between the cover and tank, reducing the chance of PDI Approvedliquids, solids or offensive odors from polluting the workplace. The seal is located in a channel, deep within the lid, Recessed Silicone IAPMO Listed*virtually eliminating the possibility of pinching, tearing or deterioration.Seal Both sewer authorities and building owners spend millions of dollars every year combating grease accumulation in plumbing systems. Grease accumulation causes sewer overflows. These overflows are a health risk to you, your employees, yourQuick Connect*No IAPMO listing available for customers and the general public. Latching System15 GPM Interceptors Designed and injection molded in high performance thermoplastic, the Endura Grease InterceptorHigh performance provides food service professionals with a proven, reliable and cost effective means of managing the grease produced in theirfoamed silicone sealAir Intake establishments before it can cause an often expensive and very unpleasant problem. Flow Control Device (FCD)Award Winning Flow Control1st Place Innovative Product Design - IndustrialProducts, ISH North America, Toronto, Ontario The Flow Control is an integral component of the Unparalleled Durability Ease of Use Light Weight Enduras design. Flow controls regulate the flow The Endura Grease Interceptor is injected molded inWeighing 1/3 the weight of competitive metal units, theand improve separation efficiency, however they engineered copolymer thermoplastic resulting in lower Endura Grease Interceptor is the lightest of its kind. It is are prone to plugging and frequent operating costs and a guaranteed longer life. The Enduraslight enough for one person to handle, resulting inmaintenance. The Endura Flow Control with seamless, leakproof construction is designed to last, even undersubstantial labor savings for installation, warehousingCleanout Lid provides quick access to the flow the most severe applications. Able to withstand continuousand transportation. The Endura can be shipped viacontrol plate, in case of blockage. External flow Uses Standard operation at temperatures of 220 F (104 C), the Endura willcourier or parcel carrier allowing for fast delivery and control makes cover removal unnecessary whenMechanical Couplings handle the demanding conditions of a commercial kitchen.freight savings. clearing blockage at the flow control plate,keeping odors contained. StrengthQuick and Easy Using the properties of our carefully selected thermoplastics to Clean the Endura can support 440 lbs. (200 kg) of pedestrian and Rather than traditionalPatented Baffle light duty traffic load. The tank, baffles and lid provide the best screw or bolt down coverExtensions Design combination of light weight and strength. The external molded connections, the Enduras All Endura models accept our patent pending extension reinforcing ribs add strength and rigidity in all applications. new Quick-Connect sets used for in-floor applications to accommodate10 YEAR WARRANTY latching system, enablesvariations in drain depth verses finished floor level. Up to The superior design and strength of Easy to Install the operator to removethree 6 extensions can be added per installation and if The footprint of the Endura has been engineered to allow a the lid with ease. Removable baffles combined with arequiring less than 6 adjustment , the extension can bethe Endura interceptor allows simple and fast retrofit of existing installations. The unit can be smooth interior surface make cleaning quick and easy. cut to suit accordingly.Canplas to guarantee the Endura Easy access provides less downtime and cost savings.Note: If installing the FCD in-floor, a standard Canplas backwater installed on floor, semi-recessed or fully recessed in the floor. valve sleeve kit can be used to maintain access from finished floor will not peel, rust or warp. level.

Recommended

View more >