2
888.653.3333 www.safti.com Fire Resistive Curtain Wall up to 2 Hours PRODUCT ADVANTAGES SPECIFICATIONS UL AND INTERTEK TESTED AND CERTIFIED Intertek and Underwriters Laboratories, nationally recognized testing laboratories approved by OSHA. FIRE RESISTIVE Contains smoke and flames, and blocks the passage of radiant heat. Profile Width: Standard 3 in. (76 mm). Weight: 12 lb./lineal foot standard Fire Rating: Up to 120 minutes with hose stream Meets ASTM E119, NFPA 251, and UL 263 Air Infiltration: Result: No Leakage. ASTM E 283-04 at 6.24 psf. ASTM E 331-00 at 20.0 psf. 3-Part Specifications: Available at www.safti.com/specifications Provides wall-to-wall and floor-to-ceiling transparency for up to 2 hours when combined with SuperLite II-XL glazing. Durable and structurally sound fire resistive aluminum clad framing system. Provides the clean appearance of conventional aluminum framing with uniform sightlines. Available in standard and custom finishes including high performance fluoropolymer finishes by PPG, clear anodized, bronze anodized, black anodized, Decoral ® , any species of wood veneer, ornamental metal and more. Can be customized to protect against hurricane, bullet, blast, noise and UV rays. Can be used in both interior and exterior applications. 5 year manufacturer’s warranty. USA manufactured for fast lead times and competitive pricing. GREEN FIRE RATED GREEN HOSE STREAM RADIANT HEAT THERMAL SHOCK POSITIVE PRESSURE Made in the USA APPROVALS UL 9, UL 10B, UL 10C, UL 263, UL 752-2005, NFPA 80, NFPA 251, NFPA 252, NFPA 257, ASTM E ANSI Z97.1, 119, ASTM E152, ASTM E163, ASTM E2074, ASTM E2010-01, CPSC 16 CFR 1201 Cat. II, ULC CAN4-S101, ULC CAN4-S104, ULC CAN4-S106, NFRC 100, NFRC 200, NFRC 500. BALLISTIC RATED 90-120 minutes 124 in. (3.15 m) 124 in. (3.15 m) Fire Rating Max. CV Area Max. CV Width Max. CV Height 45-60 minutes 124 in. (3.15 m) 124 in. (3.15 m) FRAMING: with SuperLite II-XL glazing 4,876 in. 2 (3.15 m 2 ) 4,952 in. 2 (3.19 m 2 ) GPX Curtain Wall System is listed and labeled by Static Pressure: Result: No Leakage. Dynamic Pressure Water Resistance: AAMA 501-1.05 at 12.0 psf. Result: No Leakage. Thermal Cycling and Condensation Evaluation: Exterior 170 degrees F: -10 degrees F/ Interior: 68 degrees F. Result: No Damage, No Condensation. Condensation Resistance Factor of Frame: 68 Condensation Resistance Factor of Glass: 71 Structural Performance: ASTM E-330 between -75.0 psf to 60.0 psf. Result: Passed with No Damage. Interstory Vertical Displacement Test: 1” Parallel, 1” Perpendicular. Result: No Damage. Seismic Movement Test: ¾” cycled movement horizontally. Result: No Damage. Optional 2 ½ in. (63.5 mm). TM S AFETY A ND F IRE T ECHNOLOGY I NC.

GPX Curtain Wall - safti.comFire Resistive Curtain Wall up to 2 Hours PRODUCT ADVANTAGES SPECIFICATIONS UL AND INTERTEK TESTED AND CERTIFIED Intertek and Underwriters Laboratories,

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GPX Curtain Wall - safti.comFire Resistive Curtain Wall up to 2 Hours PRODUCT ADVANTAGES SPECIFICATIONS UL AND INTERTEK TESTED AND CERTIFIED Intertek and Underwriters Laboratories,

888.653.3333www.safti.com

Fire Resistive Curtain Wallup to 2 Hours

PRODUCT ADVANTAGES

SPECIFICATIONS

UL AND INTERTEK TESTED AND CERTIFIED

Intertek and Underwriters Laboratories, nationallyrecognized testing laboratories approved by OSHA.

FIRE RESISTIVEContains smoke and fl ames, and blocks the passage of radiant heat.

Profile Width: Standard 3 in. (76 mm).

Weight: 12 lb./ lineal foot standard

Fire Rating: Up to 120 minutes with hose stream Meets ASTM E119, NFPA 251, and UL 263

Air Infiltration:Result: No Leakage.

ASTM E 283-04 at 6.24 psf.

ASTM E 331-00 at 20.0 psf.

3-Part Specifi cations:Available atwww.safti.com/specifi cations

Provides wall-to-wall and floor-to-ceiling transparency for up to 2 hours when combined with SuperLite II-XL glazing.

Durable and structurally sound fire resistive aluminum clad framing system.

Provides the clean appearance of conventional aluminum framing with uniform sightlines.

Available in standard and custom finishes including high performance fluoropolymer finishes by PPG, clear anodized, bronze anodized, black anodized, Decoral®, any species of wood veneer, ornamental metal and more.

Can be customized to protect against hurricane, bullet, blast, noise and UV rays.

Can be used in both interior and exterior applications.

5 year manufacturer’s warranty.

USA manufactured for fast lead times and competitive pricing.

GREENFIRE RATED GREEN HOSE STREAM RADIANT HEAT THERMAL SHOCK POSITIVE PRESSURE

Made in the USA

APPROVALSUL 9, UL 10B, UL 10C, UL 263, UL 752-2005, NFPA 80, NFPA 251, NFPA 252, NFPA 257, ASTM EANSI Z97.1,

119, ASTM E152, ASTM E163, ASTM E2074, ASTM E2010-01, CPSC 16 CFR 1201 Cat. II, ULC CAN4-S101, ULC CAN4-S104, ULC CAN4-S106, NFRC 100, NFRC 200, NFRC 500.

BALLISTIC RATED

90-120 minutes 124 in.(3.15 m)

124 in.(3.15 m)

Fire Rating Max. CV Area Max. CV Width Max. CV Height

45-60 minutes 124 in.(3.15 m)

124 in.(3.15 m)

FRAMING:with SuperLite II-XLglazing

4,876 in.2

(3.15 m2)

4,952 in.2

(3.19 m2)

GPX Curtain Wall System is listed and labeled by

Static Pressure:Result: No Leakage.

Dynamic Pressure Water Resistance:AAMA 501-1.05 at 12.0 psf. Result: No Leakage.

Thermal Cycling and Condensation Evaluation: Exterior 170 degrees F: -10 degrees F/ Interior: 68 degrees F. Result: No Damage, No Condensation.

Condensation Resistance Factor of Frame: 68

Condensation Resistance Factor of Glass: 71

Structural Performance: ASTM E-330 between -75.0 psf to 60.0 psf. Result: Passed with No Damage.

Interstory Vertical Displacement Test: 1” Parallel,1” Perpendicular. Result: No Damage.

Seismic Movement Test: ¾” cycled movement horizontally. Result: No Damage.

Optional 2 ½ in. (63.5 mm).

TM

S A F E T Y A N D F I R E T E C H N O L O G Y I N C .

Page 2: GPX Curtain Wall - safti.comFire Resistive Curtain Wall up to 2 Hours PRODUCT ADVANTAGES SPECIFICATIONS UL AND INTERTEK TESTED AND CERTIFIED Intertek and Underwriters Laboratories,

888.653.3333www.safti.com

The information provided herein is for reference only and is subject to change without notice. Please visit www.safti.com for the most up to date information.

FIRE RESISTIVE

FIRE RESISTIVE

FIRE RESISTIVE

FIRE RESISTIVE

VARI

ES

VARI

ES2

1/2

2 1

/2”

5”

SuperLite II-XL 120 in GPX Curtain Wall System

© SAFTI FIRST January 2017

4”

1 1/2”

1 1/2”

1 1/2”

1 1/2”

4 1/8”

4 1/8”

1 1

/2”

Project:Location: Architect: Contract Glazier: Products Used:

Weill CornellNew York, NYEnnead ArchitectsW&W Glass, LLCSuperLite II-XL 120 IGU in GPX Curtain Wall System

TYPICAL DETAILS More details available at www.safti.com/details

Fire Resistive Curtain Wallup to 2 Hours

Jamb Detail

Vertical Mullion Sill Detail

TM

S A F E T Y A N D F I R E T E C H N O L O G Y I N C .