GORDON BUTTE PUMPED STORAGE HYDRO PROJECT FERC Project No. P-13642 Absaroka Energy LLC

GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

Embed Size (px)

Citation preview

Page 1: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

GORDON BUTTEPUMPED STORAGE HYDRO PROJECT

FERC Project No. P-13642

Absaroka Energy LLC

Page 2: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

2

GORDON BUTTE PSH

Colstrip 500kV Lines

Page 3: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

3

PROJECT HIGHLIGHTS■ Installed Capacity: 400 MW

■ Flexible Capacity: 800 MW

■ Estimated storage: 8.5 hours

■ Ternary pump/turbine units: 3

■ Distance from Colstrip twin 500 kV transmission lines: 5 miles

■ Off-stream, closed-loop

■ Single private landowner

■ Martinsdale, Montana

Page 4: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

4

PROJECT LOCATION

Page 5: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

5

PROVEN TECHNOLOGY

Page 6: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

6

HYDRAULIC SHORT CIRCUIT

Page 7: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

7

ULTIMATE FLEXIBLE CAPACITYPSH can move faster (20 MW/sec) than gas (40 MW/min)

Regulation

Capacity

Page 8: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

8

DAVE GATES GENERATING STATION OPERATING GRAPH

MW

HOURS

Page 9: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

9

Source: Energy + Environmental Economics “Gordon Butte Pumped Storage: Colstrip 1&2 Replacement Analysis”

Page 10: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

10

MONTANA / WASHINGTON WIND COMPARISON

Page 11: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

11

CALIFORNIA DUCK CURVE

Page 12: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI
Page 13: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI
Page 14: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI
Page 15: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI
Page 16: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI
Page 17: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

17

PROJECT MILESTONES

Site Control

Water Right Permit

Environmental Assessment

Geotechnical

401 Water Quality Certification

Interconnection Feasibility Study

EPC Team

FERC License

Page 18: GORDON BUTTE PUMPED STORAGE HYDRO PROJECT · 11 Assuming operating state is at optimal position for providing frequency response [ex. PS pumping, GT at Prninl Energy+EnvironmentaI

Gordon Butte Team