5

GOLDEN MOUNTAIN ENTERPRISE CO. · SN series: AC 125V 0.5A/DC 100V 10W / Max. DC250V < 10 mA Service Restriction: 1. Unit Certification is not required for these products. If the manufacturer

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GOLDEN MOUNTAIN ENTERPRISE CO. · SN series: AC 125V 0.5A/DC 100V 10W / Max. DC250V < 10 mA Service Restriction: 1. Unit Certification is not required for these products. If the manufacturer
Page 2: GOLDEN MOUNTAIN ENTERPRISE CO. · SN series: AC 125V 0.5A/DC 100V 10W / Max. DC250V < 10 mA Service Restriction: 1. Unit Certification is not required for these products. If the manufacturer

As of 12/Jun/2016Type Approved

GOLDEN MOUNTAIN ENTERPRISE CO. NO.9, LANE 133, XING-HUA ST. CHIEN-CHEN DISTRICT KAOHSIUNG TAIWAN Taiwan, R.O.C. 80673 Telephone: +886-7-8135500 Fax: +886-7-8225588 Email: [email protected] Web: www.new-flow.com Tier: 3 - Type Approved, unit certification not required

Product: Magnetic Float Level Switch, Horizontal Magnetic Level SwitchModel: LS series, LR series, SLS series, LT series, Models LT201, LT202, LT203, LT204, LXT201,

LXT203S, LXT203F, LXT204, LXT205, SN series, M series, Models LT206H, LT206V,EDW series, EDX series, Models VLS5000, VLS5500 and CPLS1000

Intended Service: Liquids Level Control and Monitoring Description: These level switches, controls or transmitters are manufactured for top or side mounting on a tank as one of thecomponent within control or monitoring system; following is the Manufacturer’s self explanation based onManufacturer’s catalog for each of product:LS series: The vertical float level switch consists of a float with a built in permanent magnet, and guide tube built inreed switch (one or more).LR series of float-operated level switch suitable for control the liquid level with horizontal mounting.SLS series: Float type liquid level controls.LT series: The vertical float level transmitters consist of a float with a built in permanent magnet, and guide tube builtin many reed switch and resistances becoming a measuring sensor.LT201 and LXT201 are horizontal magnetic float type level switch with thread type connection.LT202 is horizontal magnetic float type level switch with Square Type Flange.LT203 and LXT203F are horizontal magnetic float type level switch with flange type connection for hightemperature.LXT203S is horizontal magnetic float type level switch with thread type connection for high temperature.LT204 and LXT204 are horizontal magnetic float type level switch with flange type connection.LT205 and LXT205 are vertical magnetic float type level switch with flange type connection.SN series: Application for none and low viscosity liquids system. In equipment for oil, food, beverages, medical,petrol chemical, water.M series magnetic level gauge, level switch consist of an un-magnetic chamber, magnetic float and with a built-inmagnet strips, a vertical chamber connected a tank with two end. The float raised or falls in the chamber. It turns tothe indicative strips to provide an indication of the tank level. This series also provide accessories such as switch andmeasuring sensor with converter turn to a 4-20mA (2 wires) DC output signal. To provide a liquid level controlfunction.LT206H and LXT206V are float-operated with test device level switches suitable for controlling liquid level athorizontal mounting. The float equipped with an extended arm moves a couple magnetic mechanisms to actuate amicro switch to offer an ON-OFF contact for application.EDW and EDX series: Displacer Level Switches are made to fit wide range applications such as pump control, wastewater level and deep open tank. They are designed for high corrosive resistance and long service life. 100-Series, 200-Series, 300-Series and 602-Series are one stage control and easy to install, 601-Series have multiple set points and areeasy to install and low cost.VLS5000 is assembled with a tuning fork and energized sensor. It vibrates frequently with mechanical resonance todetect the liquid level when the tuning fork is immersed into process liquid.VLS5500 is assembled with a tuning fork and energized sensor. It vibrates frequently with mechanical resonance todetect level of powders or granular bulk solids.CPLS1000 is used for measuring process vessel at the specific one point for using level alarms or for interlockinglevel control system. CPLS1000 has the ability to detect and measure both conductive and non-conductive media.CPLS1000 can be used in many industries for a wide range of applicationssuch as water, oils, and a variety of corrosive materials. Rating: 1. Degree of Protection: IP65 (LS series are available up to IP67)2. Operating Temperature:LS series: 0~60°C (P.P. float), 0~70°C (P.V.C. float), 0~120°C (PVDF float), -20~+140°C (SUS316)

Page 1 of 4

Page 3: GOLDEN MOUNTAIN ENTERPRISE CO. · SN series: AC 125V 0.5A/DC 100V 10W / Max. DC250V < 10 mA Service Restriction: 1. Unit Certification is not required for these products. If the manufacturer

As of 12/Jun/2016Type Approved

GOLDEN MOUNTAIN ENTERPRISE CO. NO.9, LANE 133, XING-HUA ST. CHIEN-CHEN DISTRICT KAOHSIUNG TAIWAN Taiwan, R.O.C. 80673 Telephone: +886-7-8135500 Fax: +886-7-8225588 Email: [email protected] Web: www.new-flow.com Tier: 3 - Type Approved, unit certification not required

LR series: -10~+120°CSLS series: 0~+60°C (P.P.), -20~+140°C (SUS316)LT series: 0~60°C (P.P. float), 0~70°C (P.V.C. float), 0~120°C (PVDF float), -20~140°C (SUS316 float)LT201, LT202, LT204, LXT201, LXT204, LT205&LXT205: -20~150°CLT203, LXT203S, LXT203F: -20~350°CLT206H/LT206V: -25~+100°CEDW100, EDX100, EDW200, EDX200, EDW300 & EDX300: <250°CEDW601, EDX601, EDW602 & EDX602: <200°CVLS5000 & VLS5500: -30~+80°CCPLS1000: -20~+120°CSN series: -20~150°CM series: 0~50°C for plastic chamber type (P.V.C., PP), -30~100°C for plastic chamber type (PVDF), -20~150°C formetal chamber type (stainless steel), -20~300°C for metal chamber type (stainless steel) on request (for this specialtype, if the operating temperature is > 250°C, the S.G. must be > 0.8)3. Media Gravity:LS series: > 0.7 (P.P. or P.V.C.), > 0.8 (PVDF float), > 0.68 or > 0.8 (SUS float depend on float size)LR series: >0.6SLS series: > 0.7 (P.P.), > 0.68 or > 0.8 (SUS float depend on float size)LT series: > 0.7 (P.P. or P.V.C.), > 0.8 (PVDF float)LT201, LT203, LT204, LT205 & LXT205: > 0.7 (option: less than 0.7 available upon request)LT202, LXT201, LXT203S, LXT203F & LXT204: > 0.7LT206H/LT206V: > 0.7 (option: less than 0.7 available upon request)EDW100, EDX100, EDW200, EDX200, EDW300 & EDX300: > 0.6EDW601 & EDX601: > 0.9EDW602 & EDX602: > 0.9 for max. length 1.2M, > 0.8 for max. length 0.8M, > 0.7~0.75 for max. length 0.5MSN series: 0.75 low limitedM series: for standard type: 500~2900 kg/m3, (for special type with high temp. > 250°C, the S.G. must be > 800kg/m34. Operating Pressure:LS series: 3 kg/cm2(P.P. or P.V.C.), 5 kg/cm2(PVDF float), 15 or 30 kg/cm2(SUS float depend on float shape)LR series: Max. 10 kg/cm2SLS series: 3 kg/cm2(P.P.), 15 or 30kg/cm2(SUS float depend on float shape)LT series: 3 kg/cm2(P.P. or P.V.C.), 5 kg/cm2(PVDF float)LT201, LXT201 & LXT203S: 3.0 MPa (30 kg/cm2), up to 4.14 MPa [see 4-6-2/5.5.5(a) of the ABS Rules for taperthread joints]LT202, LT203, LT204, LXT203F & LXT204: 3.0 MPa (30 kg/cm2), option up to 4.5 MPaLT205 & LXT205: 3.0 MPa (30kg/cm2) for E=40 mm float, option up to 4.5 MPa and 2.0 MPa (20 kg/cm2) for E=50mm floatLT206H/LT206V: 3.0 MPa (30 kg/cm2)EDW602 & EDX602: 40kg/cm2 at 25°CVLS5000 & VLS5000: maximum 100 kg/cm2, up to 400 kg/cm2 on request, up to 4.14 MPa [see 4-6-2/5.5.5(a) of theABS Rules for taper thread joints]CPLS1000: limit to 20 kg/cm2SN series: limit to 10 kg/cm2M series: plastic chamber type (P.V.C., PP) limit to 5 kg/cm2, plastic chamber type (PVDF) limit to 7 kg/cm2, metalchamber type (stainless steel) limit to 20 kg/cm2, up to 40 kg/cm2 for metal chamber type (stainless steel) on request.5. Contact Rating:LS & LR series: Contact Form A: 2A max. 230V AC/DC max., Contact Form C: 1A max. 230V AC/DC max.SLS series: 1A 230VAC/DCLT series: 4~20mA DC (500~20 k Ohm) 2-wire; LT201, LT202, LT203, LT204, LT205, LXT201, LXT203S,LXT203F, LXT204 & LXT205: 3A/250VAC, 3A/30VDC or 0.4A/125VDC; LT206H/LT206V: 15A 125/250VAC or480VAC

Page 2 of 4

Page 4: GOLDEN MOUNTAIN ENTERPRISE CO. · SN series: AC 125V 0.5A/DC 100V 10W / Max. DC250V < 10 mA Service Restriction: 1. Unit Certification is not required for these products. If the manufacturer

As of 12/Jun/2016Type Approved

GOLDEN MOUNTAIN ENTERPRISE CO. NO.9, LANE 133, XING-HUA ST. CHIEN-CHEN DISTRICT KAOHSIUNG TAIWAN Taiwan, R.O.C. 80673 Telephone: +886-7-8135500 Fax: +886-7-8225588 Email: [email protected] Web: www.new-flow.com Tier: 3 - Type Approved, unit certification not required

EDW100, EDX100, EDW200, EDX200, EDW300, EDX300, EDW602 & EDX602: 5A125VAC, 3A250VAC,3A/30VDC, 0.4A/125VDC, 0.2A/250VDCEDW601 & EDX601: consult factoryVLS5000 & VLS5000: 20A/125VAC, 12A/250VACCPLS1000: NO/NC 10A/5A 120VAC, NO/NC7A/5A 240VACSN series: AC 125V 0.5A/DC 100V 10W / Max. DC250V < 10 mA Service Restriction: 1. Unit Certification is not required for these products. If the manufacturer or purchaser request an ABS Certificatefor compliance with a specification or standard, the specification or standard, including inspection standards andtolerances, must be clearly defined. 2. If the tank level switches are installed at tank locations where they are subject to a static head of liquid they are tobe arranged such that they may be removed without emptying the tank. Not to be installed in hazardous areas. Comments: 1. The Manufacturer has provided a declaration about the control of, or the lack of Asbestos in this product.2. The subject components are to bear permanent identification, such as the manufacturer's name or trademark,material identify, pressure rating, etc. at which the manufacturer guarantees these components to meet therequirements of the manufacturer' standards. Such markings may be cast or forged integral with, stamped on, orsecurely affixed by nameplate on the component, and are to serve as a permanent means of identification of thecomponent throughout its service life in accordance with 4-6-1/7.1.3 and 4-6-1/7.1.4 of the Rules. 3. Where fitted on a remote level indicating system, plans showing the arrangements and details of the system, alongwith particulars of the sensing and transmitting devices, are to be submitted for review in each case. Notes/Drawing/Documentation: Drawing No. NA, Magnetic Float Level Switch, Horizontal Magnetic Level Switch, Revision: 0;Drawing No. 25 JUL and 27 JUN 2011, Add Models, Revision: 0;Drawing No. NA, LS series Level Switch etc, Revision: 0. Terms of Validity: This Product Design Assessment (PDA) Certificate 16-SQ1522566-PDA, dated 12/Jun/2016 remains valid until11/Jun/2021 or until the Rules or specifications used in the assessment are revised (whichever occurs first). This PDA is intended for a product to be installed on an ABS classed vessel, MODU or facility which is in existenceor under contract for construction on the date of the ABS Rules or specifications used to evaluate the Product. Use of the Product on an ABS classed vessel, MODU or facility which is contracted after the validity date of the ABSRules and specifications used to evaluate the Product, will require re-evaluation of the PDA. Use of the Product for non ABS classed vessels, MODUs or facilities is to be to an agreement between themanufacturer and intended client. STANDARDS ABS Rules: Rules for Conditions of Classification, Part 1 - 2016 Steel Vessels Rules 1-1-4/7.7, 1-1-A3, 1-1-A4, which covers thefollowing:Steel Vessels (2016): 4-6-2/9.11.3, 4-6-4/11.7 and 4-6-4/11.9;

Page 3 of 4

Page 5: GOLDEN MOUNTAIN ENTERPRISE CO. · SN series: AC 125V 0.5A/DC 100V 10W / Max. DC250V < 10 mA Service Restriction: 1. Unit Certification is not required for these products. If the manufacturer

As of 12/Jun/2016Type Approved

GOLDEN MOUNTAIN ENTERPRISE CO. NO.9, LANE 133, XING-HUA ST. CHIEN-CHEN DISTRICT KAOHSIUNG TAIWAN Taiwan, R.O.C. 80673 Telephone: +886-7-8135500 Fax: +886-7-8225588 Email: [email protected] Web: www.new-flow.com Tier: 3 - Type Approved, unit certification not required

Steel Vessels Under 90 Meters (295 feet) in Length (2016): 4-4-1/9.17.3 and 4-4-3/13.7;Offshore Support Vessels (OSV Rules) (2016): 4-6-2/9.11.3, 4-6-4/11.7 and 4-6-4/11.9;Steel Barges (2016): 4-1-2/7;High-Speed Craft (HSC Rules) (2016):1-1-4/11.9, 1-1-Appendix 2 and 3, 4-4-3/13.7. Mobile Offshore Drilling Units (MODU Rules) (2016):1-1-4/9.7, 1-1-A2, 1-1-A3, 4-2-1/11.31, 4-2-3/3.1, 4-2-3./3.7and 4-2-4/13.7.6; National: NA International: NA Government: NA EUMED: NA OTHERS: NA

Page 4 of 4