Go beyond today’s discovery Orbitrap Eclipse Tribrid mass spectrometer

Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Go beyond today’s discovery Orbitrap Eclipse Tribrid mass spectrometer

Page 2: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

2

Go beyond today’s discoveryWhen complex analytical questions require a definitive answer, you need a powerful and versatile solution that will allow you to accurately resolve subtle differences, distinguish the right answer from many wrong ones, and avoid costly dead ends.

Page 3: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

3

Introducing the Thermo Scientific™ Orbitrap Eclipse™ Tribrid™ mass spectrometer, our newest generation instrument designed with your most difficult analytical challenges in mind. With enhanced performance and usability, the Orbitrap Eclipse Tribrid mass spectrometer makes it easy to produce the high-quality data required to drive the right decisions, while expanding the breadth of your work and pushing your science beyond today’s discovery.

Go beyond today’s discovery

ANTIBODY CHARACTERIZATION CROSS-LINKING NATIVE EASY-TO-USE HDX TION TOP DOWN PERFORMANCE PTCR HDX CROSS-LINKING VERSATILITY PTCR LITY NATIVE PROTEIN STRUCTURE ELUCIDATION TOP DOWN ETD PROTE CE HDX ETD NATIVOMICS PERFORMANCE PTCR CROSS-LINKING COMPLEXES ANTIBODY CHARACTERIZATION ETD NATIVE CHARACTERIZATION PROTEIN COMPLEXES PROTEIN STRUCTURE TOP DOWN PERFORMANCE HDX ANTIBODY CHARACTER ION VERSATILITY EASY-TO-USE PTCR ETD HDX STRUC NATIVE PROTEIN STRUCTURE EASY-TO-USE ING ANTIBODY CHARACTERIZATION NATIVE E NATIVOMICS TOP DOWN ETD PROTE VE PERFORMANCE VERSATILITY PROTEIN COMPLEXES HDX ETD NATIVE PTCR CROSS-LINKIN PROTEIN STRUCTURE ANTIBODY CHAR TOP DOWN CH PTCR

Page 4: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

The Orbitrap Eclipse Tribrid mass spectrometer amplifies the power and versatility of the innovative Thermo Scientific™ Tribrid™ design by incorporating the latest inventions in ion transmission and control, extended m/z range, and real-time decision making.

These new functionalities provide ground-breaking gains in sensitivity, selectivity and versatility, making the instrument ideally suited for obtaining comprehensive results from proteomics, structural biology, small-molecule, and biopharmaceutical characterization experiments.

Building on revolutionary Tribrid architecture

4

High-Capacity Transfer Tube (HCTT)

Increases ion flux into the mass spectrometer

QR5 Segmented Quadrupole Mass Filter

with Hyperbolic SurfacesImproves sensitivity with

0.4 m/z precursor isolation widthAdvanced Active

Ion Beam GuidePrevents contaminants

from entering the mass- resolving quadrupole

EASY-IC/ETD/PTCR Ion SourceBased on Townsend discharge;

reliable and easy to use

Electrodynamic Ion FunnelFocuses ions after HCTT

Page 5: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Ultra-High-Field Orbitrap Mass Analyzer

Offers resolution >500,000 FWHM and MSn acquisition rate up to 40 Hz;

enables TurboTMT and HMRn

Ultra-High Vacuum (UHV) ManifoldReduces pressure in the UHV region; improves ion detection in the Orbitrap mass analyzer

Modified Dual-Pressure Linear Ion TrapEnables MSn for ion detection in both ion trap and Orbitrap mass analyzers; sensitive mass analysis for multiple fragmentation modes: CID, HCD, ETD/EThcD/ETciD and UVPD; and precursor ion isolation for HMRn. The extended front section of the high-pressure cell improves control over ETD and PTCR reactions.

Real-Time SearchProvides on-the-fly peptide

identification, increasing depth and accuracy of TMT

quantitation

Ion-Routing MultipoleEnable higher acquisition rates; performs HCD at any MSn stage; allows variable pressure (0.5–20 mTorr) for superior top-down performance

EASY-ETDThermo Scientific™ EASY-ETD™ HD electron transfer dissociation ion source

PTCRProton Transfer Charge Reduction

HMRn

High Mass Range MSn to m/z 8,000

FAIMS ProThermo Scientific™ FAIMS Pro™ interface

UVPDThermo Scientific™ UV Photodissociation

EASY-ICThermo Scientific™ Internal Calibration EASY-IC™ ion source

1MThermo Scientific™ 1,000,000 FWHM

Options to expand experimental versatility

5

Page 6: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Unprecedented sensitivity for single-cell analysis

Cellular systems are comprised of many different cells, each with their own set of distinct molecular and functional properties. No two cells are identical. Comprehensive characterization of single-cell proteomes will provide a wealth of novel information about cellular development in the context of disease progression and response to treatment as a function of cell type. Yet, proteome analysis with single-cell resolution remains an enormous challenge due to the analytical sensitivity this experiment demands. The Orbitrap Eclipse Tribrid mass spectrometer was developed to meet the challenge of extracting unrivaled quantitative data from ultra-low-level samples, including from individual cells. Specifically, the MS3-based Tandem Mass Tag (TMT) method, enhanced by Real-Time Search*, provides the throughput and sensitivity to achieve the proteome coverage and the quantitative accuracy needed to differentiate cell types and to capture their heterogeneity. Further, using novel Thermo Scientific™ TMTpro™ reagents, up to 16 single cells can be analyzed in one LC/MS run, providing quantitative comparison of thousands of proteins among individual cells.

6

TMT analysis of two cell types revealed more differentially expressed proteins when using SPS MS3 with Real-Time Search compared to the MS2-based experiment. The MS3 experiment allows for more accurate quantitation, enabling detection of subtle changes in more proteins for each individual cell.

* For details on Real-Time Search see pp 8–9.** Budnik et al., Genome Biol. 2018,19(1); Zhu et al., 2018, Nature Comm., 2018, 9(882).*** A total of 40 individual cells were analyzed in this study.

Novel MS3 workflow with Real-Time Search detected more than 300 differentially expressed proteins in each individual cell

Individual cells are isolated using FACS sorter, labeled, and analyzed using the Orbitrap Eclipse Tribrid mass spectrometer

MS2 SPS MS3 with Real-Time Search

Proteins quantified 901 960

Upregulated in endothelial cells (C10) 67 113

Upregulated in raw immune cells 157 195TMT10-126 -131-127N

• Endothelial cells• Raw immune cells• Epithelial cells

-127C -128N -128C -129N -129C -130C -130N

Empty** Boost**Lysis, reduction, alkylation and digestion

TMT labeling

LC/MS analysis

Pooled sample***

SPS MS3 Quant with Real-Time Search

log2(C10/Raw)

8

6

4

2

0

-log(

p-va

lue)

-6 -4 -2 0 2 4 6 8

MS2 Quant

log2(C10/Raw)

8

6

4

2

0-lo

g(p-

valu

e)

-6 -4 -2 0 2 4 6 8

Page 7: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Unprecedented sensitivity for single-cell analysisA revolution in single-cell proteomics is just beginning. The combination of nanoPOTS with the Orbitrap Eclipse Tribrid mass spectrometer, TMT reagents, and SPS MS3 with Real-Time Search provide the depth of coverage, quantitative accuracy, and throughput needed to propel this nascent field forward.”

Ryan Kelly, Professor, Brigham Young University, UT“

7

20

10

0

-10

-20 -10 0 10 20

• Endothelial cells • Raw immune cells • Epithelial cells

PCA plot showing unsupervised classification of the three cell types using TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell types and resolved heterogeneity within each type. This level of resolution is uniquely achievable using a combination of TMT-boost** and SPS MS3 with Real-Time Search data acquisition technologies.

High-resolution classification of individual cells in an SPS MS3 experiment with Real-Time Search

Confirmation of overexpression of known protein biomarkers in individual cells of each type underscores the sensitivity of the workflow

Integrin alpha-6Isoform 2 ofcollagen alpha-1(I) chain

Monocyte di�erentiationantigen CD14

Endothelialcell

Rawimmune

cell

Epithelialcell

Endothelialcell

Rawimmune

cell

Epithelialcell

Endothelialcell

Rawimmune

cell

Epithelialcell

2

3

11 (Relative abundance)

2

3

15

Quantitation channels

5

11

6

Page 8: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Hyper-accurate high-throughput protein quantitation using TMTpro 16plex and Real-Time SearchThe standard for high-throughput quantitative comparisons of protein abundances is the TMT SPS MS3 workflow, unique to Thermo Scientific™ Orbitrap™ Tribrid™ mass spectrometers. A significant advancement of the Orbitrap Eclipse Tribrid mass spectrometer is Real-Time Search, which can be used to identify peptide spectra on-the-fly to intelligently direct MS3 data acquisition, resulting in accurate quantitation to depths often exceeding 8,000 proteins in up to 16 samples per LC/MS analysis.

This new high-throughput workflow offers increased proteome coverage with improved accuracy and precision, boosting the number of quantifiable low-level peptides.

When analyzing complex peptide mixtures, co-isolated ion interferences can occur despite using narrow precursor isolation. Co-fragmentation of precursors of interest and interfering ions negatively impacts the quantitative accuracy of the TMT-based experiment.*

Every MS2 spectrum is interrogated against a database of choice using Real-Time Search in parallel with the acquisition of the next MS2 scan. If the search results in a peptide match, the instrument is directed to perform an SPS MS3 scan using only the matched fragment ions that carry the TMT tags, while avoiding any fragments that may have originated from the interfering ions. For YLYEIAR, the TMT tag was found only on the N-terminus, so the SPS MS3 is performed only on five b-ions.

* Ting et al., Nat. Methods, 2011, 8(11).

Base peak extracted ion chromatogram of the multiplexed TMT sample. The shaded region highlights a selected MS spectrum.

8

Quantitation accuracy is dependent on isolation purity

Real-Time Search improves accuracy by nearly eliminating isolation impurity

Multiplexing improves analytical throughput

Sample preparation

LC/MS analysis

MS precursor spectrum MS2

Time

MS2 isolation window

Targeted precursor

Spectralnoise level

Co-isolated interference

m/z

Peptides from digested samples labeledwith TMTpro and analyzed by LC/MS

Time

MS2 isolation window

Targeted precursor

Spectralnoise level

Co-isolated interference

m/z

Peptides from digested samples labeledwith TMTpro and analyzed by LC/MS

y

b

m/z

YLYEIAR

m/z

b1 b3

b5

b6

b4

Real-Time Searchidentifies the peptide:

Page 9: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Selecting only identified fragments for the MS3 event and excluding the ions that either do not carry the TMT tags (y-ions in this case) or that do not belong to the identified peptide increases the signal-to-noise ratio of the reporter ions and significantly improves the throughput and quantitative accuracy of the experiment (right).

The Orbitrap Eclipse Tribrid mass spectrometer provides several exciting advances which allow us to perform our analyses 100% faster with significantly improved quantification accuracy. Instead of 36 hours to perform a typical proteome-wide analysis, we can accomplish it now in 18 hours to reach between 8,000 and 10,000 quantified proteins in as many as 16 samples. This new mass spectrometer acts as if it were two instruments, collecting more accurate data in half the time, but at the same or even better depth.”

Steven P. Gygi, Professor, Harvard University, MA“

9

SPS MS3 with Real-Time Search is the most accurate method for quantitative analysis of up to 16 samples simultaneously

Increased accuracy

For each TMT channel, 4–100 pmol of a six-protein digest was added to 40 µg of HeLa digest, and then labeled, resulting in a spiked-in standard mixed in ratios of 2–24 (2, 4, 8, 12, 16 and 24). Only combined averages for the expected ratios of 2 and 24 are shown here. Higher accuracy afforded by Real-Time Search is indispensable for teasing out subtle differences in protein abundances, including when sub-classifying individual cells (pp 6–7).

Increased coverage

With Real-Time Search, 38% more peptides and 53% more proteins were quantified versus a classic SPS MS3 experiment, approaching the results of the classic MS2 experiment, but with much higher precision and accuracy (see bottom panel). Shown here are data for a TKO yeast standard (Thermo Fisher Scientific).

Increased throughput

Real-Time Search directs the mass spectrometer to perform MS3 only on identified precursors. As a result, it doubles the throughput of SPS MS3 experiments. Shown here are data for an HHM sample: three human cell lines labeled as biological replicates in 10plex (3-3-4). (Data courtesy Devin Schweppe and Qing Yu, Harvard Medical School)

1.2 1.31.4

MS2 FAIMSMS2

SPSMS3

1.7

Real-TimeSearch

SPS MS3

Expected change is 2×

8.811.6

15.2

MS2 FAIMSMS2

SPSMS3

21.2

Real-TimeSearch

SPS MS3

Expected change is 24×

9196

Real-TimeSearch

SPS MS3

10599

MS2

Quantified peptides in a 50-min LC run

63698

Real-TimeSearch

SPS MS3

Quantified peptides per LC run

6660

SPS MS3

61822

SPS MS3

180

min

90 m

in

1.2 1.31.4

MS2 FAIMSMS2

SPSMS3

1.7

Real-TimeSearch

SPS MS3

Expected change is 2×

8.811.6

15.2

MS2 FAIMSMS2

SPSMS3

21.2

Real-TimeSearch

SPS MS3

Expected change is 24×

9196

Real-TimeSearch

SPS MS3

10599

MS2

Quantified peptides in a 50-min LC run

63698

Real-TimeSearch

SPS MS3

Quantified peptides per LC run

6660

SPS MS3

61822

SPS MS3

180

min

90 m

in

1.2 1.31.4

MS2 FAIMSMS2

SPSMS3

1.7

Real-TimeSearch

SPS MS3

Expected change is 2×

8.811.6

15.2

MS2 FAIMSMS2

SPSMS3

21.2

Real-TimeSearch

SPS MS3

Expected change is 24×

9196

Real-TimeSearch

SPS MS3

10599

MS2

Quantified peptides in a 50-min LC run

63698

Real-TimeSearch

SPS MS3

Quantified peptides per LC run

6660

SPS MS3

61822

SPS MS318

0 m

in

90 m

in

TMTpro reporter ions

m/z125 135

Page 10: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Comprehensive native analysis of therapeutic proteins

Therapeutic proteins are successfully used to treat various cancers and a wide range of autoimmune diseases. However, their structural characterization presents a significant challenge because, unlike small molecule-based drugs, they exist as a heterogeneous mixture containing numerous modified proteoforms. Their highly complex ESI spectra can be simplified and made interpretable by increasing analyte m/z. This can be achieved by performing the ESI LC/MS experiment under native conditions where unfolded proteins accept fewer charges, or by performing precursor ion charge reduction in the mass spectrometer, or by both. For complete structural characterization, the mass spectrometer is required to not only detect ions within a higher m/z range, but to also fragment the selected precursor efficiently. The Orbitrap Eclipse Tribrid mass spectrometer is equipped with High Mass Range MSn capability (HMRn), Proton Transfer Charge Reduction (PTCR) and a multitude of dissociation techniques, including CID, HCD, ETD, EThcD and UVPD, making it the most powerful system available for comprehensive characterization of therapeutic proteins.

Simplifying highly complex spectra with PTCR

10

PTCR elucidates the native proteoformsProteoforms of native Cytokine Fc-fusion proteins are undecipherable

Multiple intact glycoforms are identified in deconvoluted PTCR spectrum

Average Mass

Relative Abundance

Charge State Distribution

96048.02 100.00 14–17

96070.80 58.35 14–17

96146.05 54.12 14–16

97755.20 25.85 13–16

101705.31 51.10 14–18 • • •

Native MS spectrum of intact desialyated Cytokine Fc-fusion protein after sialidase treatment with six N-linked glycosylation sites. The raw spectrum was highly complex due to the presence of multiple overlapping glycosylated proteoforms, making it challenging to interpret. The highlighted 80 m/z window represents the precursor ions that were isolated for subsequent PTCR.

PTCR dispersed the selected ion population to a higher m/z range, revealing individual molecular ion species at lower charge states. The interpretation of this spectrum provided accurate information about the mixture of different proteoforms, which were undecipherable in the original spectrum.

After deconvolution of the PTCR spectrum shown (ReSpect™ algorithm), several glycoforms of Cytokine Fc-fusion protein were identified. PTCR analysis of the entire native charge state envelope (m/z 4,000–7,000) resulted in the identification of >30 distinct glycoforms of this protein (data not shown).

96048.02

96070.8096146.05

101705.3197755.20

80000 90000 100000 110000 120000

Mass

5000 6000 7000 8000m/z

4000 5000 6000 7000m/z

16+6004.363

15+6404.420

17+5651.208 14+

6861.1417387.969

96048.02

96070.8096146.05

101705.3197755.20

80000 90000 100000 110000 120000

Mass

5000 6000 7000 8000m/z

4000 5000 6000 7000m/z

16+6004.363

15+6404.420

17+5651.208 14+

6861.1417387.969

96048.02

96070.8096146.05

101705.3197755.20

80000 90000 100000 110000 120000

Mass

5000 6000 7000 8000m/z

4000 5000 6000 7000m/z

16+6004.363

15+6404.420

17+5651.208 14+

6861.1417387.969

IgG4 Fc

Human Cytokine monomer

Page 11: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Achieving high sequence coverage of CDR3 domain

11

Native trastuzumab MS analysis Native trastuzumab MS2 analysis for structural characterization of CDR3 regions

Glycoforms Matched Mass Error (ppm)

G0/G0F 5.1

G0F/G0F 1.7

G0F/G1F 5.4

G1F/G1F 7.0

G1F/G2F 7.2

Native spectrum acquired using the HMRn mode. The 27+ species showed baseline resolution of the major glycoforms.

Representative MS2 spectra of the 27+ parent ion. The spectra were obtained by multiple fragmentation techniques and showed different fragment ion patterns, providing complementary information and increasing the primary amino acid sequence coverage for this protein.

Combined fragmentation maps (left panel) of intact trastuzumab from the native HCD, ETD, EThcD and UVPD MS2 data. Sequence coverage for light and heavy chains was 58% and 36% respectively, with combined coverage of 43% (fragment ion RMS error <3.7 ppm). Complementarity Determining Regions (CDR) 3 of the light and heavy chains are highlighted in red and blue respectively in the maps and in the crystal structure, showing 100% sequence coverage. Validation of CDR sequences is essential for studying binding affinity and efficacy of the antibody.

C

C Intramolecular disulfide bond

Intermolecular disulfide bond

CDR3 regionsFragment ion types

a b c

x y z

Heavy chain

Light chain

5000 6000m/z

G0/G0F

G0F/G0F

G0F/G1F

27+

G1F/G1F

G1F/G2F

m/z

ETD

UVPD

m/z

1000 4000 8000m/z

m/z

HCD

EThcD

1000 4000 8000

1000 4000 8000

1000 4000 8000

Page 12: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Ligands are inextricably linked to the regulation and function of the proteins to which they are bound. However, determining the identity of small-molecule ligands associated with membrane proteins is a significant challenge, underscored by the high prevalence of electron microscopy data with unassigned or poorly resolved ligand density. Direct MS identification of the ligands without losing ligand-protein complex associations is difficult because it requires a very wide mass range for retaining optimal ion transmission of intact protein assemblies of (hundreds of thousands of Daltons) and accurate detection of small-molecule ligands and their fragments (often smaller than 100 Daltons). The Orbitrap Eclipse Tribrid mass spectrometer offers a novel top-down MSn approach to facilitate identification of ligands bound to membrane proteins, allowing elucidation of specific ligands interacting with specific proteins. This approach helps to elucidate a ligand’s influence on the cascade of protein interactions that underlie cellular mechanisms, including mechanisms of cancer, diabetes, and Alzheimer’s.

Characterization of native protein-ligand complexes using HMRn

* Gault et al., Nature Methods, in press12

160 180 200 220 240 260 280 300 320 340 360m/zm/zm/z

0

50

100

Rel

ativ

e A

bund

ance

350.0

160.0173.9 191.9

332.9210.9 305.1260.0218.0163.9 321.2

1000 2000 3000 4000 5000 6000 7000 8000

6546.982

6956.361

6183.101m/z

5857.9387419.861

6546.982

17+

1000 2000 3000 4000 5000 6000 7000 8000

6546.282

6182.523 6954.955

350.0

50

100

Rel

ativ

e A

bund

ance

3000

H2O

H3N

H2N NH3

NH3

HO

OH

OH

O

OO

O

HN

HN

O

OH

OH

N

NN

S

CC

S

S

N

N6520 6540 6560 6580 6600 6620 6640

+ ligand

Intact protein-ligand assemblies in micelles are introduced directly into the mass spectrometer

Protein-ligand assemblies are released from the micelles

Intact protein complexes are extracted from the membrane using detergent. Detergent molecules form a micelle layer around the protein complex that allows solubilization. The micelles are then ionized using nESI and introduced into the mass spectrometer.

The intact membrane protein-ligand assembly is released from the detergent micelle using source-CID (pseudo MS2) and detected in the Orbitrap mass analyzer. The 17+ parent ion with associated ligands is isolated (gray bar) for the next MSn step.

lllllllllllllllllllllllllllllll

lll●●●●●●

●●●●●●●●

●●●●●●●●●

●●●●●●●●

●●

lllllllllllllllllllllllllllll

lllll●●●

●●●●●●●●

●●●●●●●●●

●●●●●●●●

●●●●●

lllllllllllllllllllllll

llllllllll

l●●●●●●

●●●●●●●●

●●●●●●●●●

●●●●●●●●

●●

lllllllllllllllllllllllllllllll

lll●●●●●

●●●●●●●●

●●●●●●●●●

●●●●●●●●

●●●

Pseudo MS2

lllllllllllllllllllllllllllllll

lll●●●●●●

●●●●●●●●

●●●●●●●●●

●●●●●●●●

●●

lllllllllllllllllllllllllllll

lllll●●●

●●●●●●●●

●●●●●●●●●

●●●●●●●●

●●●●●

llllllllllllllllllllllllllllllllll ●

●●●●●●

●●●●●●●●●

●●●●●●●●

●●●●●●●●●

lllllllllllllllllllllll

lllllllllll●●●●●●

●●●●●●●●

●●●●●●●●

●●●●●●●●

●●

lllllllllllllllllllllllllllllll

lll●●●●●

●●●●●●●●

●●●●●●●●●

●●●●●●●●

●●●

Page 13: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

13

The Orbitrap Eclipse Tribrid mass spectrometer brings a new dimension to native MS, enabling us to discover and chemically define the ligands, lipids, and drugs that regulate the function of membrane protein assemblies within one single experiment.”

Dr. Joseph Gault, University of Oxford, the UK“

160 180 200 220 240 260 280 300 320 340 360m/zm/zm/z

0

50

100

Rel

ativ

e A

bund

ance

350.0

160.0173.9 191.9

332.9210.9 305.1260.0218.0163.9 321.2

1000 2000 3000 4000 5000 6000 7000 8000

6546.982

6956.361

6183.101m/z

5857.9387419.861

6546.982

17+

1000 2000 3000 4000 5000 6000 7000 8000

6546.282

6182.523 6954.955

350.0

50

100

Rel

ativ

e A

bund

ance

3000

H2O

H3N

H2N NH3

NH3

HO

OH

OH

O

OO

O

HN

HN

O

OH

OH

N

NN

S

CC

S

S

N

N6520 6540 6560 6580 6600 6620 6640

+ ligand

The ligand is released from the protein The endogenous ligand is unambiguously identified

MS3-based isolation and activation of the intact membrane protein-ligand assembly promote the release of the ligand (m/z 350.0). This singly-charged ion is isolated (gray bar) for MS4 step to allow full structural characterization. (Note: in this experiment the ligand at m/z 350.0 was detected in the ion trap. Both the Orbitrap and the linear ion trap mass analyzers can be used to detect ions across the entire m/z range).

The MS4 spectrum contains ligand fragments detected in the ion trap. Unambiguous identification of the endogenous ligand bound to the protein is performed using established small-molecule characterization techniques. Here, ampicillin was identified bound to E. coli Outer Membrane Porin F (OmpF), forming a 111 kDa protein-ligand complex that mediates its intake. Further characterization of the protein’s primary structure is also possible using this novel top-down MSn approach.

160 180 200 220 240 260 280 300 320 340 360m/zm/zm/z

0

50

100

Rel

ativ

e A

bund

ance

350.0

160.0173.9 191.9

332.9210.9 305.1260.0218.0163.9 321.2

1000 2000 3000 4000 5000 6000 7000 8000

6546.982

6956.361

6183.101m/z

5857.9387419.861

6546.982

17+

1000 2000 3000 4000 5000 6000 7000 8000

6546.282

6182.523 6954.955

350.0

50

100

Rel

ativ

e A

bund

ance

3000

H2O

H3N

H2N NH3

NH3

HO

OH

OH

O

OO

O

HN

HN

O

OH

OH

N

NN

S

CC

S

S

N

N6520 6540 6560 6580 6600 6620 6640

+ ligand

MS4MS3

Page 14: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Reducing protein mass spectral complexity with PTCR

“PTCR is required to study large proteoforms that previously would remain uncharacterized in LC/MS experiments. Unveiling the true complexity of the intact proteome beyond the 30 kDa barrier represents asubstantial step forward for the proteomics community.”

Luca Fornelli, Professor, University of Oklahoma, OK

Top-down mass spectrometry is used to directly characterize intact proteoforms. The ESI spectral complexity of proteoform mixtures, even after LC separation, is often very high due to the multitude of modified forms that overlap in the m/z domain. PTCR technology, unique to the Orbitrap Eclipse Tribrid mass spectrometer, reduces the average charge of the parent-ion distributions, shifting them to higher m/z. For overlapping indistinguishable proteoforms this reduces the signal overlap, and, as a result, easier-to-interpret spectra are obtained, enabling the proteoform mass calculation. For automated top-down experiments, this approach increases the number of distinguishable precursors available for data-dependent MSn, ultimately increasing the number of characterized proteoforms.

6861.141

Sampled m/z space: two 1.5 m/z windows

500 1000 1500 2000m/z

ReSpect deconvolution identified 32 species from these two spectra

800 820 840 860 880 900m/z

m/z800 900 1000 1100 1200 1300 800 900 1000 1100 1200 1300m/z

0 40 60 80Time (min)

20

14

MS spectra of intact proteins are often too complex

The co-elution of multiple proteoforms increases spectral complexity, particularly when analyzing proteins >25 kDa. These spectra are often impossible to interpret fully as few charge state distributions are distinguishable by deconvolution software (e.g., only two distinct masses of 16 and 25 kDa were identified in this MS spectrum at 25 min). The 800–900 m/z region shows the underlying spectral complexity. PTCR was performed on the precursors in two 1.5 m/z windows, highlighted in gray and teal.

PTCR elucidates novel protein charge state distributions

PTCR formed lower charge state distributions of the parent ions that overlapped less and were easier to interpret. This increased the number of identifiable precursor ions from two species in the original full MS spectrum to 32 species identified after PTCR of a 3 m/z range. The newly identified masses were distributed over 10–70 kDa range (right, top histogram).

PTCR enabled detection of more and larger proteoforms

14

Single LC/MS scan at 25 min

Zoom-in m/z 800–900

PTCR

kDa

MS scan at 25 min (1500 m/z wide)Two PTCR spectra

Num

ber o

fpa

rent

ions

det

ecte

d

<30 30–40 >40

15

2

5

0

12

0

kDa

Num

ber o

f uni

que

prot

eofo

rms

iden

tified

<30 30–40 >40

79

37

83

38

68

27

Data dependentData dependent aided by PTCR

kDa

MS scan at 25 min (1500 m/z wide)Two PTCR spectra

Num

ber o

fpa

rent

ions

det

ecte

d

<30 30–40 >40

15

2

5

0

12

0

kDa

Num

ber o

f uni

que

prot

eofo

rms

iden

tified

<30 30–40 >40

79

37

83

38

68

27

Data dependentData dependent aided by PTCR

PTCR resulted in a significant increase in the number of identified proteoforms*

* Huguet, R. et al. Anal. Chem. 2019, 91(24).

Page 15: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

Application-specific methods are one click awayThe intuitive method editor features a drag-and-drop user-friendly interface with predefined, optimized method templates for a wide range of applications.

15

Edit parameters in easily accessible panels, featuring recommended defaults for each experiment

Run advanced experiments effortlessly with method templates for a large range of applications

Page 16: Go beyond today’s discovery - Thermo Fisher Scientific · TMT data. Each point corresponds to the protein expression of a single cell. The plot shows clear classification of cell

ALM

Simplify Service

Almanac online monitoring and instrument management

Stay connected to your science. For more information on how Thermo Scientific™ Almanac can help you get the most out of your instruments, visit: thermofisher.com/almanac

Protecting your investments: unparalleled laboratory services

Unity™ Lab Services provides a single source for integrated lab service, support, and supply management. Our customized service offerings and world-class service experts have the flexibility and experience to effectively address your laboratory’s business needs. We provide a complete portfolio of services and support solutions designed to help you improve productivity, reduce total cost of ownership, and ensure performance throughout your laboratory.

unitylabservices.com

Thermo Scientific™ Proteome Discoverer™ software thermofisher.com/ProteomeDiscoverer

Thermo Scientific™ ProSightPC™ and ProSightPD™ software thermofisher.com/ProSightPC

Thermo Scientific™ BioPharma Finder™ software thermofisher.com/BioPharmaFinder

Thermo Scientific™ Compound Discover™ software thermofisher.com/CompoundDiscoverer

Thermo Scientific™ Mass Frontier™ software thermofisher.com/MassFrontier

Find out more at thermofisher.com/OrbitrapEclipse

For Research Use Only. Not for use in diagnostic procedures. © 2020 Thermo Fisher Scientific Inc. All rights reserved. ReSpect algorithm is a registered trademark of Positive Probability, Ltd. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. BR65450-EN 0420M