6/04www.goodmanmfg.com
PRODUCT SPECIFICATIONS
The GMV9/GCV9 2-stage, variable-speed gas furnaces offer installation versatility.
Cabinet Construction• Heavy-gauge, reinforced, fully insulated steel cabinet with
durable baked-enamel finish• Attractive architectural gray paint finish• Foil-face insulation-lined heat exchanger compartment• Coil and furnace fit flush for easy installation• Convenient left or right connection for gas and electric
service• Bottom or side air inlet (GMV9)• Removable, solid-bottom block-off (GMV9)
Accessories• L.P. Conversion Kit (LPM-03)• Electronic Air Cleaner (EAC5)• Media Air Cleaner (MAC1)• Dehumidistat (DEHUM1)• High Altitude Pressure Switch Kit (HAPS28)• High Altitude Pressure Gas Kits (HAPS29, HALP11)• High Altitude Natural Gas Kits (HANG 13, HANG 14)• External Filter Rack (EFR01)• Horizontal/Vertical Concentric Vent
Kits (DCVK-20, DCVK-30)• Internal Filter Retention Kit—upflow, horizontal
(RF000180)• Internal Filter Retention Kit—downflow
(RF000181)• Thermostats (CHT90-120,
CH70TG, CHSATG, H20TWR)
Standard Features• Corrosion-resistant, aluminized-steel tubular heat
exchanger and stainless-steel recuperative coil for maximum efficiency
• Designed for multi-position installation—GMV9: upflow, hor i zon tal right or left; GCV9: downflow, horizontal right or left
• Energy-saving, reliable hot surface ignition system with patented adaptive learning algorithm to maximize igniter life
• Auto-Comfort mode helps to efficiently create and maintain a comfortable climate by intuitively adjusting to the room’s environment
• Aluminized-steel inshot burners• 2-stage gas valve and super-efficient, quiet variable-speed
blower motor• Quiet, 2-speed induced draft blower assembly• Integrated furnace control with improved diagnostics• Low voltage terminal blocks• Multiple flame roll-out switches, blower door safety switch,
outlet air-limit switch and pressure switch for proof of combustion air
• 40VA transformer for heating and air conditioning control service
• Combination redundant 2-stage gas valve and regulator• Top venting is standard; alternate flue/vent located on
right side• Completely assembled, factory run-tested furnace for
heating or combination heating/cooling application• All models comply with California NOx Standards• Suitable for direct vent (2-pipe) or non-direct vent (1-
pipe) applications
Heating Capacity: 69,000–115,000 BTUH
SS-376D
Multi-Position,2-Stage/Variable-Speed
Gas Furnace
GMV9/GCV9 SERIES93% AFUE
PRODUCT SPECIFICATIONS
2
Nomenclature
8 070 3G M S A N
Goodman® Brand
Air Flow Direction
M: Upflow/Horizontal
D: Dedicated Downflow
C: Downflow/Horizontal
H: Hi Air Flow
Description
S: Single Stage/Multi-speed
T: Two Stage/Multi-speed
V: Two Stage/Variable-speed
AFUE
8: 80%
9: 90%
KBTUH
045: 45,000
060: 60,000
070: 70,000
080: 80,000
090: 90,000
100: 100,000
115: 115,000
120: 120,000
140: 140,000
Cabinet Width
A: 14”
B: 17½”
C: 21”
D: 24½”
Nox
N: Natural Gas
X: Low Nox
Maximum CFM@ 0.5” ESP
3: 1,200
4: 1,600
5: 2,000
A
Revision
A: Initial Release
B: 1st Revision
3
PRODUCT SPECIFICATIONS
Specifications
ModelCirculator Blower
Vent Diameter¹
No. ofBurners
Filter Size @ 1,200 CFM (in²)
Minimum Circuit
Ampacity2 (amps)
Maximum Overcurrent Protection3
(amps)
Shipping Weight
(pounds)Size(D x W) HP Speed Permanent Disposable
GMV90704CXA 10” x 10” 3/4 Var. 2” 3 564* 627* 12.8 15 135
GMV90905DXA 11” X 10” 1 Var. 3” 4 752* 836* 14.6 15 172
GMV91155DXA 11” X 10” 1 Var. 3” 5 940* 940* 14.6 15 175
GCV90704CXA 10” x 10” 1 Var. 2” 3 320* 641* 12.8 15 135
GCV90905DXA 11” X 10” 1 Var. 3” 4 427* 854* 14.6 15 172
Performance Ratings
¹ DOE AFUE based upon Isolated Combustion System (ICS).
¹ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
² Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps.³ Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size.
NOTES:• All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply.• Gas Service Connection ½” FPT• Important: It is required to size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
ModelHigh Fire Rates (BTUH) Low Fire Rates (BTUH)
AFUE¹ Tons AC @0.5” ESP
Temperature Rise Range
(°F)Natural
Gas InputOutput Natural
Gas InputOutput
Natural LP Natural LPGMV90704CXA 69,000 64,200 55,800 48,000 44,600 36,300 93.0 1.5 - 4.0 30 - 60
GMV90905DXA 92,000 84,000 74,400 64,000 59,500 48,400 93.0 2.0 - 5.0 30 - 60
GMV91155DXA 115,000 106,500 93,000 80,000 74,400 60,500 93.0 2.0 - 5.0 35 - 65
GCV90704CXA 69,000 64,200 55,800 48,000 45,000 36,300 93.0 1.5 - 4.0 30 - 60
GCV90905DXA 92,000 84,000 74,400 64,000 60,100 48,400 93.0 2.0 - 5.0 30 - 60
PRODUCT SPECIFICATIONS
4
GMV9 Dimensions
Model A B C D
GMV90704CXA 21” 19½” 16⅜” 14⅝”GMV90905DXA 24½” 23” 20⅜” 18⅝”GMV91155DXA 24½” 23” 20⅜” 18⅝”
AIRDISCHARGE
AIRDISCHARGE
ALTERNATEGAS SUPPLY
HOLE
LOW VOLTAGEELECTRICAL HOLE
SIDE CUT-OUT
LEFT SIDEVIEW
SIDE CUT-OUT
HIGH VOLTAGEELECTRICAL HOLE
LOW VOLTAGEELECTRICAL HOLE
RIGHT SIDEDRAIN LINE
HOLES
ALTERNATEVENT/FLUE LOCATION
STANDARD GASSUPPLY HOLE
28 3/4
3/4 20 3/16 2 1/2
AIR INTAKE PIPE2" PVC
7 3/8
LEFT SIDE DRAIN LINE
HOLES
1 3/4
11 5/8
30 1/4
11 3/4
19 3/16
23
BOTTOM KNOCK-OUT25 9/16
2 11/16
VENT/FLUE PIPE2" PVC
RIGHT SIDEVIEW
2 5/830 1/4
32 13/16
19 3/16
2 5/8
11 3/4
ALTERNATEAIR INTAKE LOCATION
4 1/8
6 1/8
1 3/4
CONDENSATEDRAIN TRAPw/ 3/4" PVC
DISCHARGE(RIGHT OR LEFT SIDE)
3/4
40
3/4
2 1/16
2
BOTTOM KNOCK-OUT
C
B
D
FRONTVIEW
16 5/8
A
(DISCHARGE)
14
1 1/2
21 1/4
HIGH VOLTAGEELECTRICAL HOLE 1 3/4
DRAINTRAP
CL
27 1/8
24 9/16
DRAINTRAP
CL
Position Sides Rear Front Bottom Flue Top
Upfl ow 0” 0” 3” C 0” 1”Horizontal 6” 0” 3” C 0” 6”
Minimum Clearances to Combustible Materials
C = If placed on combustible floor, the floor MUST be wood ONLY.
NOTES:• For servicing or cleaning, a 36” front clearance is required.• Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed below.• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
NOTES:1. Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either
2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
2. Line voltage wiring can enter through the right or left side of the furnace. Low voltage wiring can enter through the right or left side of furnace.3. Conversion kits for high altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.4. Installer must supply following gas line fittings, according to which entrance is used: Left—Two 90º elbows, one close nipple, straight pipe Right—Straight pipe to reach gas valve
5
PRODUCT SPECIFICATIONS
GCV9 Dimensions
LOW VOLTAGEELECTRICAL HOLE
28 3/4
3/4 20 1/4 2 1/2AIR INTAKE PIPE
2" PVC
LEFT SIDE DRAIN LINE
HOLES
DRAINTRAP
CL
28 5/16
11 1/29 13/16
15 1/2
UNFOLDED FLANGES
1 3/4
18 5/8
2 5/8
HIGH VOLTAGEELECTRICAL HOLE
20 5/32
AIRDISCHARGE
LEFT SIDEVIEW
3/4
2 1/16
2
UNFOLDED FLANGES
DISCHARGE
CONDENSATEDRAIN TRAPw/ 3/4" PVC DISCHARGE(RIGHT OR LEFT SIDE)40
8 1/4
FOLDED FLANGES
(RETURN)3/4
HIGH VOLTAGEELECTRICAL HOLE
LOW VOLTAGEELECTRICAL HOLE
RIGHT SIDEDRAIN LINE
HOLES
ALTERNATEVENT/FLUE LOCATION
VENT/FLUE PIPE2" PVC
11 5/8
ALTERNATEAIR INTAKE LOCATION
9 3/4
DRAINTRAPCL
6 1/8
7 3/8
AIRDISCHARGE
2 5/8
ALTERNATE GASSUPPLY HOLE
RIGHT SIDEVIEW
FRONTVIEW
4 1/8
1 3/4
28 5/16
18 13/16
19 7/8
14
STANDARD GASSUPPLY HOLE
FOLDED FLANGES
2 11/16
A
B
C
D
E
5
Model A B C D E
GCV90704CXA 21” 19½” 16⅜” 18” 19½”GCV90905DXA 24½” 23” 20⅜” 21½” 23”
C = If placed on combustible floor, the floor MUST be wood ONLY.NC = For installation on non-combustible floors only. A combustible floor subbase must be used for installations on combustible flooring.
Position Sides Rear Front Bottom Flue TopDownfl ow 0” 0” 3” NC 0” 1”Horizontal 6” 0” 3” C 0” 6”
NOTES:1. Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either
2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
2. Line voltage wiring can enter through the right or left side of the furnace. Low voltage wiring can enter through the right or left side of furnace.3. Conversion kits for high altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.4. Installer must supply following gas line fittings, according to which entrance is used: Left—Two 90º Elbows, one close nipple, straight pipe Right—Straight pipe to reach gas valve
NOTES:• For servicing or cleaning, a 36” front clearance is required.• Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed below.• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
Minimum Clearances to Combustible Materials
PRODUCT SPECIFICATIONS
6
GMV9 High- or Single-Stage Cooling Speeds
GMV9 Low-Stage Cooling Speeds
Single-Stage Cooling: “Y” From T-Stat to “Y” on Two-Stage Integrated Control ModuleTwo-Stage Cooling (High Stage): “Y2” From T-Stat to “Y/Y2” on Integrated Control Module
GMV90704CXA GMV90905DXA GMV91155DXA
CoolingSpeed
Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
CoolingSpeed
Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
CoolingSpeed
Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
AMinus (-) 540
AMinus (-) 720
AMinus (-) 720
Normal 600 Normal 800 Normal 800Plus (+) 660 Plus (+) 880 Plus (+) 880
BMinus (-) 720
BMinus (-) 990
BMinus (-) 990
Normal 800 Normal 1,100 Normal 1,100Plus (+) 880 Plus (+) 1,210 Plus (+) 1,210
CMinus (-) 990
CMinus (-) 1,260
CMinus (-) 1,260
Normal 1,100 Normal 1,400 Normal 1,400Plus (+) 1,210 Plus (+) 1,540 Plus (+) 1,540
DMinus (-) 1,286
DMinus (-) 1,620
DMinus (-) 1,620
Normal 1,429 Normal 1,800 Normal 1,800Plus (+) 1,572 Plus (+) 1,980 Plus (+) 1,980
GMV90704CXA GMV90905DXA GMV91155DXACoolingSpeed
Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
CoolingSpeed
Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
CoolingSpeed
Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
AMinus (-) 378*
AMinus (-) 513*
AMinus (-) 514*
Normal 390 Normal 520 Normal 520Plus (+) 429 Plus (+) 572 Plus (+) 572
BMinus (-) 468
BMinus (-) 644
BMinus (-) 644
Normal 520 Normal 715 Normal 715Plus (+) 572 Plus (+) 787 Plus (+) 787
CMinus (-) 644
CMinus (-) 819
CMinus (-) 819
Normal 715 Normal 910 Normal 910Plus (+) 787 Plus (+) 1,001 Plus (+) 1,001
DMinus (-) 836
DMinus (-) 1,053
DMinus (-) 1,053
Normal 929 Normal 1,170 Normal 1,170Plus (+) 1,022 Plus (+) 1,287 Plus (+) 1,287
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
Two-Stage Cooling (Low Stage): “Y1” From T-Stat to “Y1” on Circulator Blower Interface Board
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
GMV9 Cooling-Based Continuous Fan
(NOTE: Only applicable for installations with single-stage cooling only, or no cooling.)Option B: “G” From T-Stat to “Y1” on Circulator Blower Interface Board
• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.* Motor CFM floor
GMV90704CXA GMV90905DXA GMV91155DXA
CoolingSpeed
Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
CoolingSpeed
Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
CoolingSpeed
Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
AMinus (-) 380*
AMinus (-) 513*
AMinus (-) 514*
Normal 380* Normal 513* Normal 514*Plus (+) 380* Plus (+) 513* Plus (+) 514*
BMinus (-) 403
BMinus (-) 554
BMinus (-) 554
Normal 448 Normal 616 Normal 616Plus (+) 493 Plus (+) 678 Plus (+) 678
CMinus (-) 554
CMinus (-) 706
CMinus (-) 706
Normal 616 Normal 784 Normal 784Plus (+) 678 Plus (+) 862 Plus (+) 862
DMinus (-) 720
DMinus (-) 907
DMinus (-) 907
Normal 800 Normal 1,008 Normal 1,008Plus (+) 880 Plus (+) 1,109 Plus (+) 1,109
7
PRODUCT SPECIFICATIONS
GMV9 Heating SpeedsGMV90704CXA
(Rise Range: 30 - 60°F)HeatingSpeed
Tap
AdjustTap
Low StageCFM @ .1” to .5” W.C. ESP
High StageCFM @ .1” to .5” W.C. ESP
Rise(°F)
AMinus (-) 756 1,089 56Normal 840 1,210 50Plus (+) 924 1,331 46
BMinus (-) 828 1,192 51Normal 920 1,325 46Plus (+) 1,012 1,457 42
CMinus (-) 900 1,296 47Normal 1,000 1,440 42Plus (+) 1,100 1,584 38
DMinus (-) 972 1,400 43Normal 1,080 1,555 39Plus (+) 1,188 1,711 35
GMV90905DXA(Rise Range: 30 - 60°F)
HeatingSpeed
Tap
AdjustTap
Low StageCFM @ .1” to .5” W.C. ESP
High StageCFM @ .1” to .5” W.C. ESP
Rise(°F)
AMinus (-) 1,013 1,458 56Normal 1,125 1,620 50Plus (+) 1,238 1,782 45
BMinus (-) 1,076 1,549 52Normal 1,195 1,721 47Plus (+) 1,315 1,893 43
CMinus (-) 1,139 1,639 49Normal 1,265 1,822 44Plus (+) 1,392 2,004 40
DMinus (-) 1,202 1,730 47Normal 1,335 1,922 42Plus (+) 1,469 2,115 38
GMV91155DXA(Rise Range: 35 - 65°F)
HeatingSpeed
Tap
AdjustTap
Low StageCFM @ .1” to .5” W.C. ESP
High StageCFM @ .1” to .5” W.C. ESP
Rise(°F)
AMinus (-) 1,107 1,594 63Normal 1,230 1,771 57Plus (+) 1,353 1,948 52
BMinus (-) 1,139 1,639 62Normal 1,265 1,822 56Plus (+) 1,392 2,004 50
CMinus (-) 1,170 1,685 60Normal 1,300 1,872 54Plus (+) 1,430 2,059 49
DMinus (-) 1,202 1,730 58Normal 1,335 1,922 53Plus (+) 1,469 2,115 48
Auto-Comfort ModeDuring Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then ramps to 82% of the full cooling demand air flow and operates there for approximately 7½ minutes. The motor then steps up to the full demand airflow. This mode spends a half minute at 50% airflow OFF delay.
100% CFM 50% CFM
½ min
82% CFM
Cooling Demand
7 ½ min
OFF OFF 50% CFM
½ min
PRODUCT SPECIFICATIONS
8
GCV9 High- or Single-Stage Cooling Speeds
GCV9 Low-Stage Cooling Speeds
GCV90704CXACooling
Speed TapAdjust
TapCFM @ .1” to .8” W.C.
ESP
AMinus (-) 540Normal 600Plus (+) 660
BMinus (-) 720Normal 800Plus (+) 880
CMinus (-) 990Normal 1,100Plus (+) 1,210
DMinus (-) 1,286Normal 1,429Plus (+) 1,572
GCV90905DXACooling
Speed TapAdjust
TapCFM @ .1” to .8” W.C.
ESP
AMinus (-) 720Normal 800Plus (+) 880
BMinus (-) 990Normal 1,100Plus (+) 1,210
CMinus (-) 1,260Normal 1,400Plus (+) 1,540
DMinus (-) 1,620Normal 1,800Plus (+) 1,980
GCV90704CXA
CoolingSpeed Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
AMinus (-) 378*Normal 390Plus (+) 429
BMinus (-) 468Normal 520Plus (+) 572
CMinus (-) 644Normal 715Plus (+) 787
DMinus (-) 836Normal 929Plus (+) 1,022
GCV90905DXA
CoolingSpeed Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
AMinus (-) 513*Normal 520Plus (+) 572
BMinus (-) 644Normal 715Plus (+) 787
CMinus (-) 819Normal 910Plus (+) 1,001
DMinus (-) 1,053Normal 1,170Plus (+) 1,287
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.* Motor CFM minimum
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.*Motor CFM minimum
GCV9 Cooling-Based Continuous FanGCV90704CXA
CoolingSpeed Tap
AdjustTap
CFM @ .1” to .8” W.C. ESP
AMinus (-) 380*Normal 380*Plus (+) 380*
BMinus (-) 403Normal 448Plus (+) 493
CMinus (-) 554Normal 616Plus (+) 678
DMinus (-) 720Normal 800Plus (+) 880
GCV90905DXACooling
Speed TapAdjust
TapCFM @ .1” to .8” W.C.
ESP
AMinus (-) 513*Normal 513*Plus (+) 513*
BMinus (-) 554Normal 616Plus (+) 678
CMinus (-) 706Normal 784Plus (+) 862
DMinus (-) 907Normal 1,008Plus (+) 1,109
• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.* Motor CFM minimum
9
PRODUCT SPECIFICATIONS
GCV90704CXA(Rise Range: 30 - 60°F)
HeatingSpeed
Tap
AdjustTap
Low StageCFM @
.1” to .5” W.C. ESP
High StageCFM @
.1” to .5” W.C. ESP
Rise(°F)
AMinus (-) 747 1,076 56Normal 830 1,195 50Plus (+) 913 1,315 46
BMinus (-) 824 1,186 51Normal 915 1,318 46Plus (+) 1,007 1,449 42
CMinus (-) 900 1,296 47Normal 1,000 1,440 42Plus (+) 1,100 1,584 38
DMinus (-) 978 1,408 43Normal 1,085 1,562 39Plus (+) 1,194 1,719 35
GCV90905DXA(Rise Range: 30 - 60°F)
HeatingSpeed
Tap
AdjustTap
Low StageCFM @
.1” to .5” W.C. ESP
High StageCFM @
.1” to .5” W.C. ESP
Rise(°F)
AMinus (-) 999 1,439 56Normal 1,110 1,598 50Plus (+) 1,221 1,758 46
BMinus (-) 1,067 1,536 52Normal 1,185 1,706 47Plus (+) 1,303 1,876 43
CMinus (-) 1,134 1,633 49Normal 1,260 1,814 44Plus (+) 1,386 1,996 40
DMinus (-) 1,202 1,730 46Normal 1,335 1,922 42Plus (+) 1,469 2,115 38
GCV9 Heating Speeds
Auto-Comfort ModeDuring Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then ramps to 82% of the full cooling demand air flow and operates there for approximately 7½ minutes. The motor then steps up to the full demand airflow. This mode spends a half minute at 50% airflow OFF delay.
100% CFM 50% CFM
½ min
82% CFM
Cooling Demand
7 ½ min
OFF OFF 50% CFM
½ min
PRODUCT SPECIFICATIONS
10
Model Description GMV90703BXA GMV90904CXA GMV91155DXA GCV90704CXA GCV90905DXA
LPM-03 L.P. Conversion Kit 1 1 1 1 1
GSAS Electronic Air Cleaner
GMU Media Air Cleaner
DEHUM1 Dehumidistat
HAPS28 High Altitude Pressure Switch Kit 2
HAPS29 High Altitude Pressure Gas Kit 2 2
HALP11 High Altitude Propane Gas Kit 2 2 2
HANG 13 High Altitude Natural Gas Kit 3 3 3
HANG 14 High Altitude Natural Gas Kit 4 4 4
EFR01 External Filter Rack
DCVK-20 Horizontal/Vertical Concentric Vent Kit (2”)
DCVK-30 Horizontal/Vertical Concentric Vent Kit (3”)
CFB21 Downfl ow Floor Base
CFB24 Downfl ow Floor Base
1) All Models up to 7,000’2) 7,001’ to 11,000’3) 7,001’ to 9,000’4) 9,001’ to 11,000’NOTE: All installations above 7,000’ require a pressure switch change.For installation in Canada, gas furnaces are certified only to 4,500’.
Accessories
11
PRODUCT SPECIFICATIONS
Thermostats
Model Description
CHT90-120 Cooling/Heating, Mechanical
CH70TG Cooling/Heating, Digital, Non-programmable
CHSATG Cooling/Heating, Mechanical
H20TWR Heating Only, Mechanical
A 2-stage thermostat should be used with the GMV9/GCV9 furnaces. A 2-stage thermostat controls which firing rate is used depending on the temperature difference between the set point and the room temperature. A properly used 2-stage thermostat and furnace will maintain a much tighter control of temperature than a conventional single-stage thermostat and furnace. A 2-stage furnace has both “W1” and “W2” terminals. If the thermostat has “Y1” and “Y2” cooling connections and a single-stage cooling system is used, connect “Y” on the furnace control to “Y1” on the thermostat. The table below describes 2-stage thermostats which have been set up for use with this furnace.
PRODUCT SPECIFICATIONS
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.Copyright © 2004 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. • Goodman® brand products are made proudly in the USA.