6/04 www.goodmanmfg.com PRODUCT SPECIFICATIONS The GMV9/GCV9 2-stage, variable-speed gas furnaces offer installation versatility. Cabinet Construction • Heavy-gauge, reinforced, fully insulated steel cabinet with durable baked-enamel finish • Attractive architectural gray paint finish • Foil-face insulation-lined heat exchanger compartment • Coil and furnace fit flush for easy installation • Convenient left or right connection for gas and electric service • Bottom or side air inlet (GMV9) • Removable, solid-bottom block-off (GMV9) Accessories • L.P. Conversion Kit (LPM-03) • Electronic Air Cleaner (EAC5) • Media Air Cleaner (MAC1) • Dehumidistat (DEHUM1) • High Altitude Pressure Switch Kit (HAPS28) • High Altitude Pressure Gas Kits (HAPS29, HALP11) • High Altitude Natural Gas Kits (HANG 13, HANG 14) • External Filter Rack (EFR01) • Horizontal/Vertical Concentric Vent Kits (DCVK-20, DCVK-30) • Internal Filter Retention Kit—upflow, horizontal (RF000180) • Internal Filter Retention Kit—downflow (RF000181) • Thermostats (CHT90-120, CH70TG, CHSATG, H20TWR) Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel recuperative coil for maximum efficiency Designed for multi-position installation—GMV9: upflow, horizontal right or left; GCV9: downflow, horizontal right or left Energy-saving, reliable hot surface ignition system with patented adaptive learning algorithm to maximize igniter life Auto-Comfort mode helps to efficiently create and maintain a comfortable climate by intuitively adjusting to the room’s environment Aluminized-steel inshot burners 2-stage gas valve and super-efficient, quiet variable-speed blower motor Quiet, 2-speed induced draft blower assembly Integrated furnace control with improved diagnostics Low voltage terminal blocks Multiple flame roll-out switches, blower door safety switch, outlet air-limit switch and pressure switch for proof of combustion air 40VA transformer for heating and air conditioning control service Combination redundant 2-stage gas valve and regulator Top venting is standard; alternate flue/vent located on right side Completely assembled, factory run-tested furnace for heating or combination heating/cooling application All models comply with California NOx Standards Suitable for direct vent (2-pipe) or non-direct vent (1- pipe) applications Heating Capacity: 69,000–115,000 BTUH SS-376D Multi-Position, 2-Stage/Variable-Speed Gas Furnace GMV9/GCV9 SERIES 93% AFUE

GMV9/GCV9 SERIES - Desco Energy SERIES.pdf · 2018. 2. 16. · 1 3/4 1 1 5/8 30 1/4 11 3/4 19 3/16 23 bottom knock-out 25 9/16 2 11/16 vent/flue pipe 2" pvc right side view 2 5/8

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • 6/04www.goodmanmfg.com

    PRODUCT SPECIFICATIONS

    The GMV9/GCV9 2-stage, variable-speed gas furnaces offer installation versatility.

    Cabinet Construction• Heavy-gauge, reinforced, fully insulated steel cabinet with

    durable baked-enamel finish• Attractive architectural gray paint finish• Foil-face insulation-lined heat exchanger compartment• Coil and furnace fit flush for easy installation• Convenient left or right connection for gas and electric

    service• Bottom or side air inlet (GMV9)• Removable, solid-bottom block-off (GMV9)

    Accessories• L.P. Conversion Kit (LPM-03)• Electronic Air Cleaner (EAC5)• Media Air Cleaner (MAC1)• Dehumidistat (DEHUM1)• High Altitude Pressure Switch Kit (HAPS28)• High Altitude Pressure Gas Kits (HAPS29, HALP11)• High Altitude Natural Gas Kits (HANG 13, HANG 14)• External Filter Rack (EFR01)• Horizontal/Vertical Concentric Vent

    Kits (DCVK-20, DCVK-30)• Internal Filter Retention Kit—upflow, horizontal

    (RF000180)• Internal Filter Retention Kit—downflow

    (RF000181)• Thermostats (CHT90-120,

    CH70TG, CHSATG, H20TWR)

    Standard Features• Corrosion-resistant, aluminized-steel tubular heat

    exchanger and stainless-steel recuperative coil for maximum efficiency

    • Designed for multi-position installation—GMV9: upflow, hor i zon tal right or left; GCV9: downflow, horizontal right or left

    • Energy-saving, reliable hot surface ignition system with patented adaptive learning algorithm to maximize igniter life

    • Auto-Comfort mode helps to efficiently create and maintain a comfortable climate by intuitively adjusting to the room’s environment

    • Aluminized-steel inshot burners• 2-stage gas valve and super-efficient, quiet variable-speed

    blower motor• Quiet, 2-speed induced draft blower assembly• Integrated furnace control with improved diagnostics• Low voltage terminal blocks• Multiple flame roll-out switches, blower door safety switch,

    outlet air-limit switch and pressure switch for proof of combustion air

    • 40VA transformer for heating and air conditioning control service

    • Combination redundant 2-stage gas valve and regulator• Top venting is standard; alternate flue/vent located on

    right side• Completely assembled, factory run-tested furnace for

    heating or combination heating/cooling application• All models comply with California NOx Standards• Suitable for direct vent (2-pipe) or non-direct vent (1-

    pipe) applications

    Heating Capacity: 69,000–115,000 BTUH

    SS-376D

    Multi-Position,2-Stage/Variable-Speed

    Gas Furnace

    GMV9/GCV9 SERIES93% AFUE

  • PRODUCT SPECIFICATIONS

    2

    Nomenclature

    8 070 3G M S A N

    Goodman® Brand

    Air Flow Direction

    M: Upflow/Horizontal

    D: Dedicated Downflow

    C: Downflow/Horizontal

    H: Hi Air Flow

    Description

    S: Single Stage/Multi-speed

    T: Two Stage/Multi-speed

    V: Two Stage/Variable-speed

    AFUE

    8: 80%

    9: 90%

    KBTUH

    045: 45,000

    060: 60,000

    070: 70,000

    080: 80,000

    090: 90,000

    100: 100,000

    115: 115,000

    120: 120,000

    140: 140,000

    Cabinet Width

    A: 14”

    B: 17½”

    C: 21”

    D: 24½”

    Nox

    N: Natural Gas

    X: Low Nox

    Maximum CFM@ 0.5” ESP

    3: 1,200

    4: 1,600

    5: 2,000

    A

    Revision

    A: Initial Release

    B: 1st Revision

  • 3

    PRODUCT SPECIFICATIONS

    Specifications

    ModelCirculator Blower

    Vent Diameter¹

    No. ofBurners

    Filter Size @ 1,200 CFM (in²)

    Minimum Circuit

    Ampacity2 (amps)

    Maximum Overcurrent Protection3

    (amps)

    Shipping Weight

    (pounds)Size(D x W) HP Speed Permanent Disposable

    GMV90704CXA 10” x 10” 3/4 Var. 2” 3 564* 627* 12.8 15 135

    GMV90905DXA 11” X 10” 1 Var. 3” 4 752* 836* 14.6 15 172

    GMV91155DXA 11” X 10” 1 Var. 3” 5 940* 940* 14.6 15 175

    GCV90704CXA 10” x 10” 1 Var. 2” 3 320* 641* 12.8 15 135

    GCV90905DXA 11” X 10” 1 Var. 3” 4 427* 854* 14.6 15 172

    Performance Ratings

    ¹ DOE AFUE based upon Isolated Combustion System (ICS).

    ¹ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.

    ² Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps.³ Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size.

    NOTES:• All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply.• Gas Service Connection ½” FPT• Important: It is required to size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

    ModelHigh Fire Rates (BTUH) Low Fire Rates (BTUH)

    AFUE¹ Tons AC @0.5” ESP

    Temperature Rise Range

    (°F)Natural

    Gas InputOutput Natural

    Gas InputOutput

    Natural LP Natural LPGMV90704CXA 69,000 64,200 55,800 48,000 44,600 36,300 93.0 1.5 - 4.0 30 - 60

    GMV90905DXA 92,000 84,000 74,400 64,000 59,500 48,400 93.0 2.0 - 5.0 30 - 60

    GMV91155DXA 115,000 106,500 93,000 80,000 74,400 60,500 93.0 2.0 - 5.0 35 - 65

    GCV90704CXA 69,000 64,200 55,800 48,000 45,000 36,300 93.0 1.5 - 4.0 30 - 60

    GCV90905DXA 92,000 84,000 74,400 64,000 60,100 48,400 93.0 2.0 - 5.0 30 - 60

  • PRODUCT SPECIFICATIONS

    4

    GMV9 Dimensions

    Model A B C D

    GMV90704CXA 21” 19½” 16⅜” 14⅝”GMV90905DXA 24½” 23” 20⅜” 18⅝”GMV91155DXA 24½” 23” 20⅜” 18⅝”

    AIRDISCHARGE

    AIRDISCHARGE

    ALTERNATEGAS SUPPLY

    HOLE

    LOW VOLTAGEELECTRICAL HOLE

    SIDE CUT-OUT

    LEFT SIDEVIEW

    SIDE CUT-OUT

    HIGH VOLTAGEELECTRICAL HOLE

    LOW VOLTAGEELECTRICAL HOLE

    RIGHT SIDEDRAIN LINE

    HOLES

    ALTERNATEVENT/FLUE LOCATION

    STANDARD GASSUPPLY HOLE

    28 3/4

    3/4 20 3/16 2 1/2

    AIR INTAKE PIPE2" PVC

    7 3/8

    LEFT SIDE DRAIN LINE

    HOLES

    1 3/4

    11 5/8

    30 1/4

    11 3/4

    19 3/16

    23

    BOTTOM KNOCK-OUT25 9/16

    2 11/16

    VENT/FLUE PIPE2" PVC

    RIGHT SIDEVIEW

    2 5/830 1/4

    32 13/16

    19 3/16

    2 5/8

    11 3/4

    ALTERNATEAIR INTAKE LOCATION

    4 1/8

    6 1/8

    1 3/4

    CONDENSATEDRAIN TRAPw/ 3/4" PVC

    DISCHARGE(RIGHT OR LEFT SIDE)

    3/4

    40

    3/4

    2 1/16

    2

    BOTTOM KNOCK-OUT

    C

    B

    D

    FRONTVIEW

    16 5/8

    A

    (DISCHARGE)

    14

    1 1/2

    21 1/4

    HIGH VOLTAGEELECTRICAL HOLE 1 3/4

    DRAINTRAP

    CL

    27 1/8

    24 9/16

    DRAINTRAP

    CL

    Position Sides Rear Front Bottom Flue Top

    Upfl ow 0” 0” 3” C 0” 1”Horizontal 6” 0” 3” C 0” 6”

    Minimum Clearances to Combustible Materials

    C = If placed on combustible floor, the floor MUST be wood ONLY.

    NOTES:• For servicing or cleaning, a 36” front clearance is required.• Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed below.• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

    NOTES:1. Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either

    2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.

    2. Line voltage wiring can enter through the right or left side of the furnace. Low voltage wiring can enter through the right or left side of furnace.3. Conversion kits for high altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.4. Installer must supply following gas line fittings, according to which entrance is used: Left—Two 90º elbows, one close nipple, straight pipe Right—Straight pipe to reach gas valve

  • 5

    PRODUCT SPECIFICATIONS

    GCV9 Dimensions

    LOW VOLTAGEELECTRICAL HOLE

    28 3/4

    3/4 20 1/4 2 1/2AIR INTAKE PIPE

    2" PVC

    LEFT SIDE DRAIN LINE

    HOLES

    DRAINTRAP

    CL

    28 5/16

    11 1/29 13/16

    15 1/2

    UNFOLDED FLANGES

    1 3/4

    18 5/8

    2 5/8

    HIGH VOLTAGEELECTRICAL HOLE

    20 5/32

    AIRDISCHARGE

    LEFT SIDEVIEW

    3/4

    2 1/16

    2

    UNFOLDED FLANGES

    DISCHARGE

    CONDENSATEDRAIN TRAPw/ 3/4" PVC DISCHARGE(RIGHT OR LEFT SIDE)40

    8 1/4

    FOLDED FLANGES

    (RETURN)3/4

    HIGH VOLTAGEELECTRICAL HOLE

    LOW VOLTAGEELECTRICAL HOLE

    RIGHT SIDEDRAIN LINE

    HOLES

    ALTERNATEVENT/FLUE LOCATION

    VENT/FLUE PIPE2" PVC

    11 5/8

    ALTERNATEAIR INTAKE LOCATION

    9 3/4

    DRAINTRAPCL

    6 1/8

    7 3/8

    AIRDISCHARGE

    2 5/8

    ALTERNATE GASSUPPLY HOLE

    RIGHT SIDEVIEW

    FRONTVIEW

    4 1/8

    1 3/4

    28 5/16

    18 13/16

    19 7/8

    14

    STANDARD GASSUPPLY HOLE

    FOLDED FLANGES

    2 11/16

    A

    B

    C

    D

    E

    5

    Model A B C D E

    GCV90704CXA 21” 19½” 16⅜” 18” 19½”GCV90905DXA 24½” 23” 20⅜” 21½” 23”

    C = If placed on combustible floor, the floor MUST be wood ONLY.NC = For installation on non-combustible floors only. A combustible floor subbase must be used for installations on combustible flooring.

    Position Sides Rear Front Bottom Flue TopDownfl ow 0” 0” 3” NC 0” 1”Horizontal 6” 0” 3” C 0” 6”

    NOTES:1. Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either

    2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.

    2. Line voltage wiring can enter through the right or left side of the furnace. Low voltage wiring can enter through the right or left side of furnace.3. Conversion kits for high altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.4. Installer must supply following gas line fittings, according to which entrance is used: Left—Two 90º Elbows, one close nipple, straight pipe Right—Straight pipe to reach gas valve

    NOTES:• For servicing or cleaning, a 36” front clearance is required.• Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed below.• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

    Minimum Clearances to Combustible Materials

  • PRODUCT SPECIFICATIONS

    6

    GMV9 High- or Single-Stage Cooling Speeds

    GMV9 Low-Stage Cooling Speeds

    Single-Stage Cooling: “Y” From T-Stat to “Y” on Two-Stage Integrated Control ModuleTwo-Stage Cooling (High Stage): “Y2” From T-Stat to “Y/Y2” on Integrated Control Module

    GMV90704CXA GMV90905DXA GMV91155DXA

    CoolingSpeed

    Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    CoolingSpeed

    Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    CoolingSpeed

    Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    AMinus (-) 540

    AMinus (-) 720

    AMinus (-) 720

    Normal 600 Normal 800 Normal 800Plus (+) 660 Plus (+) 880 Plus (+) 880

    BMinus (-) 720

    BMinus (-) 990

    BMinus (-) 990

    Normal 800 Normal 1,100 Normal 1,100Plus (+) 880 Plus (+) 1,210 Plus (+) 1,210

    CMinus (-) 990

    CMinus (-) 1,260

    CMinus (-) 1,260

    Normal 1,100 Normal 1,400 Normal 1,400Plus (+) 1,210 Plus (+) 1,540 Plus (+) 1,540

    DMinus (-) 1,286

    DMinus (-) 1,620

    DMinus (-) 1,620

    Normal 1,429 Normal 1,800 Normal 1,800Plus (+) 1,572 Plus (+) 1,980 Plus (+) 1,980

    GMV90704CXA GMV90905DXA GMV91155DXACoolingSpeed

    Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    CoolingSpeed

    Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    CoolingSpeed

    Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    AMinus (-) 378*

    AMinus (-) 513*

    AMinus (-) 514*

    Normal 390 Normal 520 Normal 520Plus (+) 429 Plus (+) 572 Plus (+) 572

    BMinus (-) 468

    BMinus (-) 644

    BMinus (-) 644

    Normal 520 Normal 715 Normal 715Plus (+) 572 Plus (+) 787 Plus (+) 787

    CMinus (-) 644

    CMinus (-) 819

    CMinus (-) 819

    Normal 715 Normal 910 Normal 910Plus (+) 787 Plus (+) 1,001 Plus (+) 1,001

    DMinus (-) 836

    DMinus (-) 1,053

    DMinus (-) 1,053

    Normal 929 Normal 1,170 Normal 1,170Plus (+) 1,022 Plus (+) 1,287 Plus (+) 1,287

    • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.

    Two-Stage Cooling (Low Stage): “Y1” From T-Stat to “Y1” on Circulator Blower Interface Board

    • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.

    GMV9 Cooling-Based Continuous Fan

    (NOTE: Only applicable for installations with single-stage cooling only, or no cooling.)Option B: “G” From T-Stat to “Y1” on Circulator Blower Interface Board

    • Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.* Motor CFM floor

    GMV90704CXA GMV90905DXA GMV91155DXA

    CoolingSpeed

    Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    CoolingSpeed

    Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    CoolingSpeed

    Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    AMinus (-) 380*

    AMinus (-) 513*

    AMinus (-) 514*

    Normal 380* Normal 513* Normal 514*Plus (+) 380* Plus (+) 513* Plus (+) 514*

    BMinus (-) 403

    BMinus (-) 554

    BMinus (-) 554

    Normal 448 Normal 616 Normal 616Plus (+) 493 Plus (+) 678 Plus (+) 678

    CMinus (-) 554

    CMinus (-) 706

    CMinus (-) 706

    Normal 616 Normal 784 Normal 784Plus (+) 678 Plus (+) 862 Plus (+) 862

    DMinus (-) 720

    DMinus (-) 907

    DMinus (-) 907

    Normal 800 Normal 1,008 Normal 1,008Plus (+) 880 Plus (+) 1,109 Plus (+) 1,109

  • 7

    PRODUCT SPECIFICATIONS

    GMV9 Heating SpeedsGMV90704CXA

    (Rise Range: 30 - 60°F)HeatingSpeed

    Tap

    AdjustTap

    Low StageCFM @ .1” to .5” W.C. ESP

    High StageCFM @ .1” to .5” W.C. ESP

    Rise(°F)

    AMinus (-) 756 1,089 56Normal 840 1,210 50Plus (+) 924 1,331 46

    BMinus (-) 828 1,192 51Normal 920 1,325 46Plus (+) 1,012 1,457 42

    CMinus (-) 900 1,296 47Normal 1,000 1,440 42Plus (+) 1,100 1,584 38

    DMinus (-) 972 1,400 43Normal 1,080 1,555 39Plus (+) 1,188 1,711 35

    GMV90905DXA(Rise Range: 30 - 60°F)

    HeatingSpeed

    Tap

    AdjustTap

    Low StageCFM @ .1” to .5” W.C. ESP

    High StageCFM @ .1” to .5” W.C. ESP

    Rise(°F)

    AMinus (-) 1,013 1,458 56Normal 1,125 1,620 50Plus (+) 1,238 1,782 45

    BMinus (-) 1,076 1,549 52Normal 1,195 1,721 47Plus (+) 1,315 1,893 43

    CMinus (-) 1,139 1,639 49Normal 1,265 1,822 44Plus (+) 1,392 2,004 40

    DMinus (-) 1,202 1,730 47Normal 1,335 1,922 42Plus (+) 1,469 2,115 38

    GMV91155DXA(Rise Range: 35 - 65°F)

    HeatingSpeed

    Tap

    AdjustTap

    Low StageCFM @ .1” to .5” W.C. ESP

    High StageCFM @ .1” to .5” W.C. ESP

    Rise(°F)

    AMinus (-) 1,107 1,594 63Normal 1,230 1,771 57Plus (+) 1,353 1,948 52

    BMinus (-) 1,139 1,639 62Normal 1,265 1,822 56Plus (+) 1,392 2,004 50

    CMinus (-) 1,170 1,685 60Normal 1,300 1,872 54Plus (+) 1,430 2,059 49

    DMinus (-) 1,202 1,730 58Normal 1,335 1,922 53Plus (+) 1,469 2,115 48

    Auto-Comfort ModeDuring Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then ramps to 82% of the full cooling demand air flow and operates there for approximately 7½ minutes. The motor then steps up to the full demand airflow. This mode spends a half minute at 50% airflow OFF delay.

    100% CFM 50% CFM

    ½ min

    82% CFM

    Cooling Demand

    7 ½ min

    OFF OFF 50% CFM

    ½ min

  • PRODUCT SPECIFICATIONS

    8

    GCV9 High- or Single-Stage Cooling Speeds

    GCV9 Low-Stage Cooling Speeds

    GCV90704CXACooling

    Speed TapAdjust

    TapCFM @ .1” to .8” W.C.

    ESP

    AMinus (-) 540Normal 600Plus (+) 660

    BMinus (-) 720Normal 800Plus (+) 880

    CMinus (-) 990Normal 1,100Plus (+) 1,210

    DMinus (-) 1,286Normal 1,429Plus (+) 1,572

    GCV90905DXACooling

    Speed TapAdjust

    TapCFM @ .1” to .8” W.C.

    ESP

    AMinus (-) 720Normal 800Plus (+) 880

    BMinus (-) 990Normal 1,100Plus (+) 1,210

    CMinus (-) 1,260Normal 1,400Plus (+) 1,540

    DMinus (-) 1,620Normal 1,800Plus (+) 1,980

    GCV90704CXA

    CoolingSpeed Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    AMinus (-) 378*Normal 390Plus (+) 429

    BMinus (-) 468Normal 520Plus (+) 572

    CMinus (-) 644Normal 715Plus (+) 787

    DMinus (-) 836Normal 929Plus (+) 1,022

    GCV90905DXA

    CoolingSpeed Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    AMinus (-) 513*Normal 520Plus (+) 572

    BMinus (-) 644Normal 715Plus (+) 787

    CMinus (-) 819Normal 910Plus (+) 1,001

    DMinus (-) 1,053Normal 1,170Plus (+) 1,287

    • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.* Motor CFM minimum

    • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.*Motor CFM minimum

    GCV9 Cooling-Based Continuous FanGCV90704CXA

    CoolingSpeed Tap

    AdjustTap

    CFM @ .1” to .8” W.C. ESP

    AMinus (-) 380*Normal 380*Plus (+) 380*

    BMinus (-) 403Normal 448Plus (+) 493

    CMinus (-) 554Normal 616Plus (+) 678

    DMinus (-) 720Normal 800Plus (+) 880

    GCV90905DXACooling

    Speed TapAdjust

    TapCFM @ .1” to .8” W.C.

    ESP

    AMinus (-) 513*Normal 513*Plus (+) 513*

    BMinus (-) 554Normal 616Plus (+) 678

    CMinus (-) 706Normal 784Plus (+) 862

    DMinus (-) 907Normal 1,008Plus (+) 1,109

    • Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.* Motor CFM minimum

  • 9

    PRODUCT SPECIFICATIONS

    GCV90704CXA(Rise Range: 30 - 60°F)

    HeatingSpeed

    Tap

    AdjustTap

    Low StageCFM @

    .1” to .5” W.C. ESP

    High StageCFM @

    .1” to .5” W.C. ESP

    Rise(°F)

    AMinus (-) 747 1,076 56Normal 830 1,195 50Plus (+) 913 1,315 46

    BMinus (-) 824 1,186 51Normal 915 1,318 46Plus (+) 1,007 1,449 42

    CMinus (-) 900 1,296 47Normal 1,000 1,440 42Plus (+) 1,100 1,584 38

    DMinus (-) 978 1,408 43Normal 1,085 1,562 39Plus (+) 1,194 1,719 35

    GCV90905DXA(Rise Range: 30 - 60°F)

    HeatingSpeed

    Tap

    AdjustTap

    Low StageCFM @

    .1” to .5” W.C. ESP

    High StageCFM @

    .1” to .5” W.C. ESP

    Rise(°F)

    AMinus (-) 999 1,439 56Normal 1,110 1,598 50Plus (+) 1,221 1,758 46

    BMinus (-) 1,067 1,536 52Normal 1,185 1,706 47Plus (+) 1,303 1,876 43

    CMinus (-) 1,134 1,633 49Normal 1,260 1,814 44Plus (+) 1,386 1,996 40

    DMinus (-) 1,202 1,730 46Normal 1,335 1,922 42Plus (+) 1,469 2,115 38

    GCV9 Heating Speeds

    Auto-Comfort ModeDuring Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then ramps to 82% of the full cooling demand air flow and operates there for approximately 7½ minutes. The motor then steps up to the full demand airflow. This mode spends a half minute at 50% airflow OFF delay.

    100% CFM 50% CFM

    ½ min

    82% CFM

    Cooling Demand

    7 ½ min

    OFF OFF 50% CFM

    ½ min

  • PRODUCT SPECIFICATIONS

    10

    Model Description GMV90703BXA GMV90904CXA GMV91155DXA GCV90704CXA GCV90905DXA

    LPM-03 L.P. Conversion Kit 1 1 1 1 1

    GSAS Electronic Air Cleaner

    GMU Media Air Cleaner

    DEHUM1 Dehumidistat

    HAPS28 High Altitude Pressure Switch Kit 2

    HAPS29 High Altitude Pressure Gas Kit 2 2

    HALP11 High Altitude Propane Gas Kit 2 2 2

    HANG 13 High Altitude Natural Gas Kit 3 3 3

    HANG 14 High Altitude Natural Gas Kit 4 4 4

    EFR01 External Filter Rack

    DCVK-20 Horizontal/Vertical Concentric Vent Kit (2”)

    DCVK-30 Horizontal/Vertical Concentric Vent Kit (3”)

    CFB21 Downfl ow Floor Base

    CFB24 Downfl ow Floor Base

    1) All Models up to 7,000’2) 7,001’ to 11,000’3) 7,001’ to 9,000’4) 9,001’ to 11,000’NOTE: All installations above 7,000’ require a pressure switch change.For installation in Canada, gas furnaces are certified only to 4,500’.

    Accessories

  • 11

    PRODUCT SPECIFICATIONS

    Thermostats

    Model Description

    CHT90-120 Cooling/Heating, Mechanical

    CH70TG Cooling/Heating, Digital, Non-programmable

    CHSATG Cooling/Heating, Mechanical

    H20TWR Heating Only, Mechanical

    A 2-stage thermostat should be used with the GMV9/GCV9 furnaces. A 2-stage thermostat controls which firing rate is used depending on the temperature difference between the set point and the room temperature. A properly used 2-stage thermostat and furnace will maintain a much tighter control of temperature than a conventional single-stage thermostat and furnace. A 2-stage furnace has both “W1” and “W2” terminals. If the thermostat has “Y1” and “Y2” cooling connections and a single-stage cooling system is used, connect “Y” on the furnace control to “Y1” on the thermostat. The table below describes 2-stage thermostats which have been set up for use with this furnace.

  • PRODUCT SPECIFICATIONS

    Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.Copyright © 2004 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. • Goodman® brand products are made proudly in the USA.