Global GSS® Grid Storage Solution Installations

1 MW/3 MWh

2013

2.5 MW/5 MWh

2013

1 MW/1 MWh

2013

11 MW/4.4 MWh

2012

500 kW/125 kWh

2013

400 kW/100 kWh

2010

12 MW/4 MWh

2009

20 MW/5 MWh

2011

32 MW/8 MWh

2011

2 MW/500 kWh

2013

8 MW/2 MWh

2011

Frequency Regulation

Renewable Integration

Primary Reserve

T&D Support

4 MW/1 MWh

2011

2 MW/500 kWh

2013

2 MW/500 kWh

2008

20 MW/5 MWh

2013

1 MW/2.8 MWh

2014

350 kW/700 kWh

2013

280kW/135kWh

2014

2 MW/2 MWh

2014

2.5 MW/3.9 MWh

2015

Page 3: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Los Andes, Chile - 12MW/4MWh GSS®

▐ Primary Reserve▐ 12MW Power Capability▐ 4MWh Energy Capacity ▐ 8 Battery Containers▐ Integrated Inverter and Cooling▐ Operational since 2009

“the Los Andes battery energy storage system is one of the best performing reserve units in Northern Chile”

‐CDEC‐SING, system operator in Northern Chile

Page 4: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Auwahi, HI - 11MW/4.3MWh GSS®

▐ Wind Ramp Management▐ 11 MW Power Capability▐ 4.3 MWh Energy Capacity ▐ 9 Battery Containers

▐ 3 Inverter Containers▐ External Chillers, Transformers▐ Operational December 2012

Page 5: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Westminster, CA - 4MW/1MWh GSS®

▐ Frequency Regulation▐ 4 MW Power Capability▐ 1 MWh Energy Capacity ▐ Two Containers with Integrated Inverters▐ External Chillers and Transformers▐ Operational since 2011

Page 6: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Angamos, Chile - 20 MW/5MWh GSS®

▐ Primary Reserve▐ 20MW Power Capability▐ 5 MWh Energy Capacity ▐ 10 Battery Containers

The International Recipient of the 85th Annual EEI Edison Award

▐ 5 Inverter Containers with Integrated Transformers▐ External Chillers▐ Operational since 2011

Page 7: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Laurel Mountain (WV) - 32MW/8MWh GSS®

▐ Frequency Regulation▐ 32 MW Power Capability▐ 8 MWh Energy Capacity ▐ 16 Battery Containers

Recipient of the 2012 Excellence in Renewable Energy Award for Wind Project of the Year. 

▐ 8 Inverter Containers▐ External Chillers, Transformers▐ Operational since 2011

Page 8: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Johnson City, NY - 8MW/2MWh GSS®

▐ Frequency Regulation▐ 8 MW Installed Power Capability▐ 2 MWh Installed Energy Capacity ▐ Four Containers with Integrated Inverters

▐ External Chillers and Transformers▐ Refurbished after a major flood Sep 2011▐ Relocated all ten containers to a different

location in Aug 2013

Page 9: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Soma, Japan - 1MW/2.8MWh GSS®

▐ Peak load management▐ 1 MW Power Capability▐ 2.8 MWh Energy Capacity

▐ One battery container w/integrated cooling▐ One inverter container▐ Operational March 2013

Page 10: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

▐ Frequency Regulation▐ 20MW Power Capability▐ 5MWh Energy Capacity

Dayton, OH - 20MW/5MWh GSS®

▐ Ten Containers with Integrated Inverters▐ External Chillers and Transformers▐ Operational September 2013

Page 11: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Darlington, UK - 2.5MW/5MWh GSS®

▐ T&D Support Pilot▐ 2.5 MW Power Capability▐ 5 MWh Energy Capacity ▐ Two Battery Containers

with Integrated Cooling

▐ One Inverter Container▐ Installed at the Rise Carr substation▐ Commissioned December 2013

Page 12: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

▐ T&D Support Pilot▐ Peak Shaving, Power Balancing, Voltage Regulation, Frequency Regulation,

Black Start▐ 2 MW Power Capability▐ 2 MWh Energy Capacity

Calabria, Italy - 2MW/2MWh GSS®

Page 13: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Seville, Spain - 1MW/3MWh GSS®

▐ 1 MW Power Capability▐ 3 MWh Energy Capacity ▐ One battery container w/ integrated cooling▐ One inverter container▐ Operational December 2013

▐ Renewable time-shift, VAR support, frequency regulation, and voltage regulation in mixed-mode operation

Page 14: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Wailea, HI - 1MW/1MWh GSS®

▐ Peak Shaving▐ 1 MW/1MWh Capability▐ 1 Battery Container▐ 1 Inverter Container▐ Operational June 2013

Page 15: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Orange, CA - 2.5MW/3.9MWh GSS®

▐ T&D support pilot▐ Supporting Southern California Edison

distribution grid for improved power reliability

▐ 2.5 MW Power Capability▐ 3.9 MWh Energy Capacity

▐ Custom battery enclosure w/integrated cooling

▐ One inverter container▐ Operational July 2015

Page 16: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Beijing, China - 2MW/500kWh GSS®

▐ Frequency Regulation▐ 2 MW Power Capability▐ 500kWh Energy Capacity ▐ 1 Battery Container▐ 1 Inverter Container▐ Operational Jun 2013

Page 17: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Huntington Beach, CA - 2MW/500kWh GSS®

▐ 2MW Power Capability▐ 500kWh Energy Capacity ▐ 1 Battery Container▐ Integrated Inverter and Cooling▐ Operational since 2009▐ Application: Frequency Regulation

Page 18: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Denmark - 400kW/100kWh GSS®

▐ Wind Ramp Management▐ 400 kW Power Capability▐ 100 kWh Energy Capacity ▐ 1 Battery Containers▐ Integrated Inverter and Cooling▐ Operational since 2010

Page 19: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Darlington, UK - 50kW/100kWh GSS®

▐ T&D Support Pilot▐ One LD Rack▐ One 50kW/kVA inverter with integrated isolation transformer▐ One AEROS® Control Rack▐ Installed in a pre-existing building at the Harrowgate Hill substation▐ Commissioned Dec 2013

Harrowgate Hill substation

GSS® installed in a pre‐existing building

Page 20: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

▐ T&D Support Pilot▐ Two LD Racks▐ One 100kW/kVA inverter with

integral isolation transformer▐ One AEROS® Control Rack▐ Installed inside a custom

container with integral cooling at the High Northgate substation

▐ Commissioned Dec 2013

Darlington, UK - 100kW/200kWh GSS®

Page 21: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Wooler, UK - 100kW/200kWh GSS®

▐ T&D Support Pilot▐ Two LD Racks▐ One 100kW/kVA inverter with integral

isolation transformer▐ One AEROS® Control Rack▐ All installed inside a pre-existing building

with modified structure and integral cooling at the Wooler Ramsey substation

▐ Commissioned Dec 2013

Page 22: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Wooler, UK - 100kW/200kWh GSS®

▐ T&D Support Pilot▐ Two LD Racks▐ One 100kW/kVA inverter with integral isolation transformer▐ One AEROS® Control Rack▐ Installed in a custom enclosure with integral cooling at the

Wooler St. Mary substation▐ Commissioned Dec 2013

Page 23: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

▐ T&D Support Pilot▐ One LD Rack▐ One 50kW/kVA inverter with

integral isolation transformer▐ One AEROS® Control Rack▐ Installed inside a secure

custom enclosure with integral cooling in a residential area in Maltby (not at a substation)

▐ Commissioned Dec 2013

Maltby, UK - 50kW/100kWh GSS®

Page 24: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

Hangzhou, China - 500kW/125kWh GSS®

▐ Microgrid Support▐ Five HR Racks▐ One 500kW/kVA

inverter ▐ One AEROS® control

rack▐ All installed in a pre-

existing building at Dong Fang Electric Machinery Co. site, co-located with local wind, solar, and thermal generation

▐ Commissioned March 2014

• Renewable time‐shift, VAR support, frequency regulation, and voltage regulation in mixed‐mode operation

Page 25: Global GSS® Installations

©2016 NEC Energy Solutions, Inc. All rights reserved.

▐ T&D Support Pilot▐ Backup, Renewable Integration, Peak Shaving, and Voltage Regulation▐ 280 kW Power Capability▐ 135 kWh Energy Capacity

Rome, Italy - 280kW/135kWh GSS®