13
IT IS THE BUILDERS RESPONSIBILITY TO CONFIRM DEPTH & LOCATION OF ALL SERVICES PRIOR TO CONSTRUCTION AS THIS MAY AFFECT THE DESIGN. 1048 1049 1050 1051 1052 1053 1054 1055 1056 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1050 1049 Low Wet Area Dam Dam Dam Dam Dam Solar Hybrid Bore Box Culvert 12/1850/500 IL 1049.98 IL 1049.78 IL 1056.55 IL 1056.47 Ø750 REFER CIV01-02 PROPOSED ALL WEATHER ENTRY ROAD TO BE DOCUMENTED AT CC STAGE, SUBJECT TO COUNCILS DESIGN REQUIREMENTS 1% AEP EXTENT EXISTING WATERCOURSE LEGEND EXISTING FINISHED SURFACE LEVEL, CONTOURS SHOWN ARE ALSO EXISTING INDICATES DIRECTION OF SURFACE FLOW OVERLAND FLOW PATH PROPOSED HARDSTAND LAYDOWN AREA TO HAVE RUNOFF SHEET FLOW ALONG EXISTING CONTOUR GRADES. EXISTING DAM TO BE REMOVED EXISTING DAM TO BE REMOVED EXISTING WATERCOURSE EXISTING SWALE TO BE REDIRECTED TO FOLLOW THE PROPOSED OVERLAND FLOW PATH SHEET SIZE REVISION DRAWING No. PROJECT REF No. SCALE DRN DRAWING STATUS R E V I S I O N S REV DATE CHK APP A1 DRAWING STATUS NOT FOR CONSTRUCTION STORMWATER MANAGEMENT PLAN GLEN INNES SOLAR FARM , GLEN INNES PROVIDENCE ASSET GROUP ISSUED FOR CLIENT REVIEW DRN REV DATE CHK APP M.M. M.M. F.M. 01.12.20 A 200521 CIV01 B 1:2000 COPYRIGHT - This drawing and the information provided shall remain the property of DRB Consulting Engineers Pty Ltd (DRB) and may not be used, copied or reproduced, in whole or part, for any purpose other than that for which it was supplied without the prior consent of DRB. North This drawing is not approved for construction unless signed. Mathew McNamara BEng (Civil) Hons MIE (Aust) ISSUED FOR DA M.M. M.M. F.M. 08.12.20 B

Glen Innes Sydney - gisc.nsw.gov.au

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Glen Innes Sydney - gisc.nsw.gov.au

IT IS THE BUILDERS RESPONSIBILITYTO CONFIRM DEPTH & LOCATIONOF ALL SERVICES PRIOR TOCONSTRUCTION AS THISMAY AFFECT THE DESIGN.

1048

1049

1050

1051

1052

1053

1054

1055

1056

1056

1057

1058105

91060

1061106

2

1063

1064

1065

1066

1051

1052105

3105

4105

51056105

71058

1059

10601061

1062106

3

1050

1049

Low

Wet

Area

Dam

Dam

Dam

Dam

Dam

Solar Hybrid Bore

Box

Culve

rt12/1

850/

500

IL 1

049.

98

IL 1

049.

78

IL 1

056.

55

IL 1

056.

47

Ø750

REFER CIV01-02

PROPOSED ALL WEATHER ENTRY ROAD TO BEDOCUMENTED AT CC STAGE, SUBJECT TOCOUNCILS DESIGN REQUIREMENTS

1% AEP EXTENT

EXISTING WATERCOURSE

LEGENDEXISTING FINISHED SURFACE LEVEL, CONTOURS SHOWN ARE ALSO EXISTINGINDICATES DIRECTION OF SURFACE FLOWOVERLAND FLOW PATH

PROPOSED HARDSTAND LAYDOWN AREATO HAVE RUNOFF SHEET FLOW ALONGEXISTING CONTOUR GRADES.

EXISTING DAM TO BE REMOVED

EXISTING DAM TO BE REMOVED

EXISTING WATERCOURSE

EXISTING SWALE TO BE REDIRECTED TO FOLLOWTHE PROPOSED OVERLAND FLOW PATH

SHEET SIZE

REVISIONDRAWING No.PROJECT REF No.

SCALE

DRN DRAWING STATUS

R E

V I

S I O

N S

REV DATE CHK APP

A1DRAWING STATUS

NOT FOR CONSTRUCTIONSTORMWATER MANAGEMENT PLANGLEN INNES SOLAR FARM ,GLEN INNESPROVIDENCE ASSET GROUP

ISSUED FOR CLIENT REVIEW

DRNREV DATE CHK APP

M.M.M.M.F.M.01.12.20A 200521 CIV01 B

1:2000

COPYRIGHT - This drawing and the information provided shall remain the property of DRBConsulting Engineers Pty Ltd (DRB) and may not be used, copied or reproduced, in whole or part,for any purpose other than that for which it was supplied without the prior consent of DRB.

North

This drawing is not approved for construction unless signed.

Mathew McNamara BEng (Civil) Hons MIE (Aust)

ISSUED FOR DAM.M.M.M.F.M.08.12.20B

Page 2: Glen Innes Sydney - gisc.nsw.gov.au

Dam

BATTER 1V:3H

5.5m WIDE WEIR AT RL 1050.358.5M WIDE WEIR AT 1050.50

1m TOP OF BANK

INV. 1050.15

Ø150 LOW FLOW PIPEPROVIDE GABION ROCKMATTRESS ON OUTLETTO LIMIT EROSION.

AREA OF DISTURBANCE = 183m2

BATTER 1V:3H

ONSITE STORMWATERDETENTION BASIN

BASE RL - 1050.15m AHDTOP OF BANK RL - 1050.50m AHD

TOTAL VOLUME - 210.21m3

1% AEP EXTENT

IT IS THE BUILDERS RESPONSIBILITYTO CONFIRM DEPTH & LOCATIONOF ALL SERVICES PRIOR TOCONSTRUCTION AS THISMAY AFFECT THE DESIGN.

LEGENDINV. INVERT LEVEL uPVC STORMWATER PIPE

EXISTING SURFACE CONTOUROVERLAND FLOW PATHPROPOSED CONTOUR LEVEL7.90

SHEET SIZE

REVISIONDRAWING No.PROJECT REF No.

SCALE

CHK APP

A1DRAWING STATUS

NOT FOR CONSTRUCTIONPROPOSED BASIN PLANGLEN INNES SOLAR FARM ,GLEN INNESPROVIDENCE ASSET GROUP

ISSUED FOR CLIENT REVIEW

DRNREV DATE CHK APP

M.M.M.M.F.M.01.12.20A 200521 CIV02 B

1:100

DRN DRAWING STATUS

R E

V I

S I O

N S

REV DATE

COPYRIGHT - This drawing and the information provided shall remain the property of DRBConsulting Engineers Pty Ltd (DRB) and may not be used, copied or reproduced, in whole or part,for any purpose other than that for which it was supplied without the prior consent of DRB.

North

This drawing is not approved for construction unless signed.

Mathew McNamara BEng (Civil) Hons MIE (Aust)

ISSUED FOR DAM.M.M.M.F.M.08.12.20B

Page 3: Glen Innes Sydney - gisc.nsw.gov.au

Sydney

Glen Innes

9/12/2020 11:42:00 AM

Page 4: Glen Innes Sydney - gisc.nsw.gov.au

1

0

4

8

1

0

4

9

1

0

5

0

1

0

5

1

1

0

5

2

1

0

5

3

1

0

5

4

1

0

5

5

1

0

5

6

1

0

5

6

1

0

5

7

1

0

5

8

1

0

5

9

1

0

6

0

1

0

6

1

1

0

6

2

1

0

6

3

1

0

6

4

1065

1066

1

0

5

1

1

0

5

2

1

0

5

3

1

0

5

4

1

0

5

5

1

0

5

6

1

0

5

7

1

0

5

8

1

0

5

9

1

0

6

0

1

0

6

1

1

0

6

2

1

0

6

3

1

0

5

0

1

0

4

9

Lot 36

D

P

1834

Lot 35

D

P

1834

Lot 4

D

P

1834

Lot 3

D

P

1834

Lot 2

D

P

1834

Lot 1

D

P

1834

Lot 1 D

P

251457

Lot 7023

D

P

1059104

Lot 508

D

P

753282

Lot 507

D

P

753282

Lot 506

D

P

753282

Lot 488

D

P

753282

Lot 389

D

P

753282

Lot 58

D

P

1834

Lot 5

D

P

1834

Lot 31

D

P

1834

Lot 37

D

P

1834

Furracabad C

reek

Furracabad C

reek

F

u

r

r

a

c

a

b

a

d

C

r

e

e

k

L

o

t 3

4

D

P

1

8

3

4

L

o

t 3

3

D

P

1

8

3

4

L

o

t 3

2

D

P

1

8

3

4

GDA 2020/MGA ZONE 56

374912.07m E,

6711525.71m S

TU

TT

LE

S

LA

N

E

9/12/2020 11:42:45 AM

Page 5: Glen Innes Sydney - gisc.nsw.gov.au

1

0

4

8

1

0

4

9

1

0

5

0

1

0

5

1

1

0

5

2

1

0

5

3

1

0

5

4

1

0

5

5

1

0

5

6

1

0

5

6

1

0

5

7

1

0

5

8

1

0

5

9

1

0

6

0

1

0

6

1

1

0

6

2

1

0

6

3

1

0

6

4

1065

1066

1

0

5

1

1

0

5

2

1

0

5

3

1

0

5

4

1

0

5

5

1

0

5

6

1

0

5

7

1

0

5

8

1

0

5

9

1

0

6

0

1

0

6

1

1

0

6

2

1

0

6

3

1

0

5

0

1

0

4

9

²²

TU

TT

LE

S

LA

N

E

9/12/2020 11:43:36 AM

Page 6: Glen Innes Sydney - gisc.nsw.gov.au

1

0

4

8

1

0

4

9

1

0

5

0

1

0

5

1

1

0

5

2

1

0

5

3

1

0

5

4

1

0

5

5

1

0

5

6

1

0

5

6

1

0

5

7

1

0

5

8

1

0

5

9

1

0

6

0

1

0

6

1

1

0

6

2

1

0

6

3

1

0

6

4

1

0

5

6

1

0

5

7

1

0

5

8

1

0

5

5

1

0

5

6

IL 1056.55

IL 1056.47

Ø

750

10/12/2020 3:29:48 PM

Page 7: Glen Innes Sydney - gisc.nsw.gov.au

9/12/2020 11:23:04 AM

Page 8: Glen Innes Sydney - gisc.nsw.gov.au

9/12/2020 11:38:22 AM

Page 9: Glen Innes Sydney - gisc.nsw.gov.au

9/12/2020 11:34:32 AM

Page 10: Glen Innes Sydney - gisc.nsw.gov.au

9/12/2020 11:28:03 AM

Page 11: Glen Innes Sydney - gisc.nsw.gov.au

9/12/2020 11:26:28 AM

Page 12: Glen Innes Sydney - gisc.nsw.gov.au

9/12/2020 11:26:51 AM

Page 13: Glen Innes Sydney - gisc.nsw.gov.au

9/12/2020 11:30:31 AM