Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
CR
ED
EN
ZA
DISHWASHER
INTEGRAL
LIFT
LIFT
LIFT
LIFT
LIFT
LIFT
LIFT LOBBY
MALE WC
ELEC CUPBD
LIFT
ELEC RISER
LIFT LOBBY
STAIRWELL 2
LIFT LOBBY
LIFT
ELEC RISER
FIRE HOSE
W
IN
SLE
Y S
TR
EE
T
LIGHT WELL 2
DIS. WC
WALK IN
SHOWER
FEMALE WC
CLEANER
S
E
LF
-S
E
R
V
IC
E
R
E
FR
E
S
H
M
E
N
TS
STAIRWELL 4
G
R
E
A
T T
IT
C
H
FIE
LD
S
TR
E
E
T
EASTCASTLE STREET
B
R
IC
K
E
FF
E
C
T F
IN
IS
H
WAITING
BREAKOUT
RECEPTION
MEET(12)
MEET(16)
COMMS
ROOM
CONFERENCE
ROOM
OFFICE
CEO
OFFICE
OFFICEOFFICE
HOT DESKS
/MEET
BREAKOUT AREA
BREAKOUT
AREA
COPIER /
PRINTER
POINT
PRINTER
POINT
OFFICE
TEA POINT
N4-02
N4-03
N4-06
N4-07
N4-08
N4-09
N4-10
N4-11
N4-12
N4-15 N4-16 N4-17
FRIDGE
TALL
EXISTING DEMISE
EXISTING DEMISE
DISHWASHER
INTEGRAL
N4-18
VP
VP
N4-13
PA
OFFICE
N4-14
ACCESS
CONTROL
ACCESS
CONTROL
MEET(12)
DATA
PROVISION
FOR ACCESS
CONTROL
DATA
PROVISION
FOR ACCESS
CONTROL
DATA
PROVISION
FOR ACCESS
CONTROL
C
O
A
TS
W
H
IT
E
B
O
A
R
D
OFFICE
WH
IT
EB
OA
RD
WILLFUL PETRAN
W
OR
K-W
ALL
WO
RK
-W
AL
LW
OR
K-W
AL
L
AV
S
CR
EE
NS
WIT
H C
AM
ER
A
AV
S
CR
EE
N
WIT
H C
AM
ER
A
CR
ED
EN
ZA
AV
S
CR
EE
N
WIT
H C
AM
ER
A
WH
IT
E B
OA
RD
WH
IT
E B
OA
RD
Existing structural basebuild wall
Keys not to scale
Some symbols shown might not appear on the drawing
Existing partition
New 75mm solid stud partition (Single skin)
New 100mm solid stud partition (Single skin)
New 100mm solid stud partition (Double skin)
New 196mm partition (Double skin)
New partition(Detail t.b.c.)
Note:- All partitions to be 'raised floor to
underside of suspended ceiling' - Unless
otherwise noted (See below)
RF - CS
FS - USC
FS - CSPARTITION
PARTITION
PARTITION
CV
PARTITION
STRENGTHENING
SOUND
BARRIER
FIRE
BARRIER
P
PARTITION
STRENGTHENING
M
FV
CVFV
Raised floor to ceiling slab
Floor slab to underside of
suspended ceiling
Floor slab to ceiling slab
Sound barrier partition
FV = 'In floor void'
CV = 'In ceiling void'
Plywood partition strengthening
Mdf partition strengthening
Fire barrier partition
FV = 'In floor void'
CV = 'In ceiling void'
GLAZING DETAILS
KEY TO GENERAL ARRANGEMENT DETAILS
Existing silicon glass
Existing glazed module
New single glazed silicon glass
New double glazed silicon glass
New single glazed module
New double glazed module
DOOR DETAILS
Standard height doors
unless otherwise stated
EX1=Existing 1st floor
=Door No.
N1=New 1st floor
V.P. = Vision panel SEC = Security door
R1 = 1st floor room
01
= Room no.
W1 = 1st floor window
01
= Window no.
Comms floor Vinyl floor Wood floor Tiled floor
Existing
furniture
New
furniture
Expansion
furniture
Medium height
(Drawer unit)
High height
(Door unit)
Low height
(Tambour unit)
Cloaks
Storagewall
Roller
Storage
General
Storagewall
Racking System Filing CabinetCredenza
DDA compliant
benching / worksurface
General
shelving
Benching /
Worksurface
Full height doors
unless otherwise stated
01
RX1=Relocated 1st floor
FD20S= Fire door rated with smoke seal
FD20S =20 min FD30S =30 min FD60S =60 min
N1-01
W1-01
Existing
door
Relocated
door
New solid
framed door
New glass
door
ARCHITECTURAL TECHNICIAN:
DESIGN DIRECTOR:
TECHNICAL DIRECTOR:
STUDIO LEAD:
DATE:
AS BUILT
PRE CONSTRUCTION / APPROVAL / CONSTRUCTION/ AS BUILT
Notes: This drawing must be signed otherwise it will be invalid
Building parameters taken from as built drawings provided
Check survey undertaken only, subject to statutory approval
All dimensions shown are in millimetres unless otherwise shown
QUALITY CONTROL
MARIS
CHECKED BY:
CLIENT
SIGNED:
PRINT NAME:
ON BEHALF OF:
DATE:
MARIS INTERIORS LLP
The Harlequin Building
65 Southwark Street
London SE1 0HR
T
E
W
020 7902 1750
maris-interiors.co.uk
Willful Holdings
4th Floor - General Arrangement
21282 01 4th GA AB
2 Great Titchfield St
London
W1D 1NN
AJH
06/05/2016
1:100@A1