VFC LEVEL 112' - 7 1/2"
VFC LEVEL 223' - 8 1/2"
VFC LEVEL 334' - 5 1/2"
123456789101112131415
T.O. MECH53' - 3 1/2"
CONCOURSE LEVEL16' - 3 1/2"
6.4 3.5
A201
1
A201
2
6.11617 0.9
114114
VFC LEVEL 112' - 7 1/2"
VFC LEVEL 223' - 8 1/2"
VFC LEVEL 334' - 5 1/2"
VFC BASEMENT1' - 6 1/2"
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
T.O. MECH53' - 3 1/2"
FIELD LEVEL0' - 0"
CONCOURSE LEVEL16' - 3 1/2"
A202
1
A202
2
16 170.9
Copyright HNTB 2015
23456789101112131415
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
DRAWN BY
PROJECT NO.
CHECKED BY
APPROVED BY
ISSUED FOR:
...
...
...
SHEET TITLE & NUMBER
HNTB Oregon Architecture, P.C.HNTB Oregon Architecture, P.C.HNTB Oregon Architecture, P.C.HNTB Oregon Architecture, P.C.
One Bunker Hill601 West Fifth Street, Suite 1000Los Angeles, CA 90071(213) 403-1000 / Fax (213) 403-1001
1
OR
EG
ON
ST
AT
E U
NIV
ER
SIT
YC
OR
VA
LLI
S, O
RE
GO
N
DATE
STRUCTURAL:KPFF Consulting Engineers111 SW Fifth Avenue, Suite 2500Portland, OR 97204PH (503) 227-3251/FAX (503) 227-7980
CIVIL:KPFF Consulting Engineers111 SW Fifth Avenue, Suite 2500Portland, OR 97204PH (503) 542-3251/FAX (503) 274-4681
LANDSCAPE:Mayer / Reed319 SW Washington Street, Suite 820Portland, OR 97204PH (503) 223-5953/FAX (503) 223-8076
SIGNAGE & GRAPHIC:Mayer / Reed319 SW Washington Street, Suite 820Portland, OR 97204PH (503) 223-5953/FAX (503) 223-8076
MECHANICAL & PLUMBING:Systems West Engineers411 High StreetEugene, OR 97401PH (541) 342-7210/FAX (541) 342-7220
ELECTRICAL & LIGHTING:Stantec733 SW Oak Street, Suite 200Portland, OR 97205PH (503) 273-0064
FIRE PROTECTION & CODE:FP&C Consultants inc.One Ward Parkway, Suite 200Kansas City, MO 64112PH (816) 931-3377/FAX (816) 931-3378
SOUND/ AV/ TEL:WJHW3424 Midcourt Rd, Suite 124Carrollton, TX 75006PH (972) 934-3700/FAX (972) 934-3720
ELEVATOR CONSULTING:ECS15600 NE 8th Street, Suite B1, PMB 148Bellevue, WA 98008PH (425) 957-4641
OVERALL BUILDINGELEVATIONS -
NORTH & SOUTH
A200
60562
12.09.2015
PKG-3 NORTH END ZONE & VFCRENOVATION
PKG-3 NORTH END
ZONE & VFC
RENOVATION
12.0
9.20
15P
KG
-3 N
OR
TH
EN
D Z
ON
E &
VF
C R
EN
OV
AT
ION
VA
LLE
Y F
OO
TB
ALL
CE
NT
ER
/N
OR
TH
EN
D Z
ON
E R
EN
OV
AT
ION
1/16" = 1'-0"A200
1 NORTH ELEVATION
1/16" = 1'-0"A200
2 SOUTH ELEVATION
1 3 5 7 10 1513
A
C
E
G
H
J
KEY PLAN
1
2
REFERENCE KEYNOTE
SPEC.# DESCRIPTION
SHEET NOTES
114 NORTH ENTRANCE ARCH, STRUCT,& M.E.P. SCOPEWILL BE ISSUED AS PART OF PKG-5 - NORTHENTRANCE.
# DATE DESCRIPTION
VFC LEVEL 112' - 7 1/2"
VFC LEVEL 223' - 8 1/2"
VFC LEVEL 334' - 5 1/2"
VFC BASEMENT1' - 6 1/2"
1 2 3 4 5 6 7
T.O. MECH53' - 3 1/2"
FIELD LEVEL0' - 0"
CONCOURSE LEVEL16' - 3 1/2"
6.43.5
FIELD PADDING ON CONCRETEWALL AT PERIMETER TYP.
EXISTING WALL FINISH TO BEPAINTED : ADD ALTERNATE 4SEE SHEET G001
LOWER BOWL SEATING
18' -
10"
10' -
9"
11' -
1"
11' -
1"
1' -
6 9
/16"
53' -
3 9
/16"
136' - 0"
24' - 0" 28' - 0" 12' - 6" 15' - 6" 12' - 0" 20' - 0" 9' - 0" 15' - 0"
LOCKER ROOM-0' - 6"
EXISTING SCOREBOARD
CONCRETE WALL GLASS GUARDRAILSYSTEM W/ 2" DIA. RAIL &1/2" THK. TEMP. GLASSEXPOSED CMU
BURNISHED FINISH
GLASS GUARDRAIL SYSTEMW/ 2" DIA. RAIL & 1/2" THK.TEMP. GLASS
LOCATION OF CAMERAPLATFORM (N.I.C.)
FIELD LIGHT POLES
CENTRIA (OR SIMILAR) INTERCEPTMODULAR METAL PANEL SYSTEM(LIMESTONE COLOR) OVER COLDMETAL STUDS FRAME & RIGIDINSULATION
0.9
VFC LEVEL 112' - 7 1/2"
VFC LEVEL 223' - 8 1/2"
VFC LEVEL 334' - 5 1/2"
VFC BASEMENT1' - 6 1/2"
8 9 10 11 12 13 14 15
T.O. MECH53' - 3 1/2"
FIELD LEVEL0' - 0"
CONCOURSE LEVEL16' - 3 1/2"
7.1
18' -
10"
10' -
9"
11' -
1"
11' -
1"
1' -
6 9
/16"
3' -
7 1
5/16
"
53' -
3 9
/16"
9' - 0" 20' - 0" 12' - 0" 16' - 0" 16' - 0" 24' - 0" 24' - 0" 20' - 0"
EXISTING ROOFING AND FASCIAPANEL TO BE PAINTED A DIFFERENTCOLOR : ADD ALTERNATE 3 SEESHEET G001
FIELD PADDING ON CONCRETE WALLAT PERIMETER TYP.
EXISTING WINDOW TOREMAIN
EXISTING WALL FINISH TO BEPAINTED : ADD ALTERNATE 4SEE SHEET G001
GLASS GUARDRAIL SYSTEMW/ 2" DIA. RAIL & 1/2" THK.TEMP. GLASS
METAL PANEL OVER STUDFRAMING & RIGID INSULATIONTYP.
STOREFRONT GLAZING SYSTEM
EXPOSED CMU WITHBURNISHED FINISH TYP.
CENTRIA (OR SIMILAR) INTERCEPTMODULAR METAL PANEL SYSTEM(LIMESTONE COLOR) OVER COLDFORMED METAL STUDS FRAME FORELEVATOR ENCLOSURE / ADJACENTSTAIR TO BE OPEN
FIELD LIGHT POLE
16 17
METAL WALL PANELS074213
PIPE GUARDRAILS AT BRIDGE. GALV.& PTD. BY METAL STAIRCONTRACTOR
WALL SECTIONS & DETAILS GENERAL NOTES:
1. REFER TO SHEET A___ FOR CURTAIN /STOREFRONT TYPES SCHEULE & GLASS TYPESSCHEDULE
2. THE BRICK MASONRY CONTRACTOR SHALLDESIGN, ENGINEER, FABRICATE, ASSEMBLE ANDINSTALL ALL COMPONENTS OF THE BRICKMASONRY WALL INCLUDING BUT NOT LIMITED TOTHE FULL FACE BRICK TIES, LEDGER/RELIEFANGLES AS SPECIFIED PER SECTION 01 62 11 -DELEGATED DESIGN REQUIREMENTS.
3. THE CONTRACTOR SHALL ENGINEER ANDINSTALL METAL FRAMING AS SPECIFIED IN THEDELEGATED DESIGN REQUIREMENTS OFSPECIFCATIONS.
4. ALL EXTERIOR EXPOSED STRUCTURAL AND NONSTRUCTURAL METAL FRAMING SHALL HAVE PAINTFINISH.
Copyright HNTB 2015
23456789101112131415
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
DRAWN BY
PROJECT NO.
CHECKED BY
APPROVED BY
ISSUED FOR:
...
...
...
SHEET TITLE & NUMBER
HNTB Oregon Architecture, P.C.HNTB Oregon Architecture, P.C.HNTB Oregon Architecture, P.C.HNTB Oregon Architecture, P.C.
One Bunker Hill601 West Fifth Street, Suite 1000Los Angeles, CA 90071(213) 403-1000 / Fax (213) 403-1001
1
OR
EG
ON
ST
AT
E U
NIV
ER
SIT
YC
OR
VA
LLI
S, O
RE
GO
N
DATE
STRUCTURAL:KPFF Consulting Engineers111 SW Fifth Avenue, Suite 2500Portland, OR 97204PH (503) 227-3251/FAX (503) 227-7980
CIVIL:KPFF Consulting Engineers111 SW Fifth Avenue, Suite 2500Portland, OR 97204PH (503) 542-3251/FAX (503) 274-4681
LANDSCAPE:Mayer / Reed319 SW Washington Street, Suite 820Portland, OR 97204PH (503) 223-5953/FAX (503) 223-8076
SIGNAGE & GRAPHIC:Mayer / Reed319 SW Washington Street, Suite 820Portland, OR 97204PH (503) 223-5953/FAX (503) 223-8076
MECHANICAL & PLUMBING:Systems West Engineers411 High StreetEugene, OR 97401PH (541) 342-7210/FAX (541) 342-7220
ELECTRICAL & LIGHTING:Stantec733 SW Oak Street, Suite 200Portland, OR 97205PH (503) 273-0064
FIRE PROTECTION & CODE:FP&C Consultants inc.One Ward Parkway, Suite 200Kansas City, MO 64112PH (816) 931-3377/FAX (816) 931-3378
SOUND/ AV/ TEL:WJHW3424 Midcourt Rd, Suite 124Carrollton, TX 75006PH (972) 934-3700/FAX (972) 934-3720
ELEVATOR CONSULTING:ECS15600 NE 8th Street, Suite B1, PMB 148Bellevue, WA 98008PH (425) 957-4641
ENLARGEDELEVATION -
SOUTH
A202
60562
12.09.2015
PKG-3 NORTH END ZONE & VFCRENOVATION
PKG-3 NORTH END
ZONE & VFC
RENOVATION
12.0
9.20
15P
KG
-3 N
OR
TH
EN
D Z
ON
E &
VF
C R
EN
OV
AT
ION
VA
LLE
Y F
OO
TB
ALL
CE
NT
ER
/N
OR
TH
EN
D Z
ON
E R
EN
OV
AT
ION
1 3 5 7 10 1513
A
C
E
G
H
J
KEY PLAN
1/8" = 1'-0"A202
2 SOUTH ELEVATION
1/8" = 1'-0"A202
1 SOUTH ELEVATION
12
REFERENCE KEYNOTE
SPEC.# DESCRIPTION
074213 METAL WALL PANELS
SHEET NOTES
# DATE DESCRIPTION