Upload
james-tate
View
215
Download
0
Tags:
Embed Size (px)
Citation preview
Gilian Air Sampling PumpsGilian Air Sampling PumpsIf they were any tougher they would beat you up and take your lunch money.
Introduction to GilianIntroduction to Gilian
• Gilian air sampling pumps are manufactured by Sensidyne in Clearwater, Florida.
• Product line includes personal and area air sampling pumps for the evaluation of worker exposure to airborne hazards during the work shift.
Air Sampling IntroductionAir Sampling Introduction
• Air sampling pumps draw air through collection media for the evaluation of worker exposure to a targeted substance during the work shift.
• Samples are collected using a filter cassette or sorbent tube then later analyzed in a lab.
Meet the Gilian FamilyMeet the Gilian Family
Gilian 5000Gilian 5000
• Constant flow: 1000-5000 cc/min
• Low flow: 20-750 cc/min
• High backpressure capability
• Memory free NiMH battery
• Programmable functionality– Four stage program with repeat cycling
– Allows scheduled sampling or intermittent duty cycles
– Programmable delayed start
• Digital live flow display
• En1232 Compliant – 3rd party verified
• Intuitive operation with lock out
• Intrinsically safe certified
Gilian GilAir-3Gilian GilAir-3
• Constant flow: 750-3000 cc/min• Low flow: 1-750 cc/min • Rechargeable battery pack• Built-in rotameter & flow adjust • Multiple sorbent tube capability • Programmable LCD clock timer • Instant-fault function • Compact, lightweight, & quiet • UL listed intrinsically safe • ATEX & CE approved • Full one-year warranty
Gilian GilAir-5Gilian GilAir-5
• Constant flow: 750-5000 cc/min • Low flow: 1-750 cc/min• Rechargeable battery pack• Built-in rotameter & flow adjust• Multiple sorbent tube capability• Programmable LCD clock timer• Instant-fault function• Compact, lightweight, & quiet• UL listed intrinsically safe• ATEX & CE approved • Full one-year warranty
Gilian LFS-113Gilian LFS-113
• Constant flow: 5-200 cc/min • Multi-tube flow: 1-350 cc/min• Elapsed time clock • Built-in sorbent tube end breaker • Multi-tube sorbent tube sampling
capability • Suction and discharge sampling • Instant-fault functions • Battery check LEDs • Rechargeable Battery Pack
Gilian BDX-IIGilian BDX-II
• Flow: 500-3000 cc/min • Rechargeable battery pack • Built-in rotameter & flow adjust• Compact, lightweight, & quiet • Low-cost designed for use with
asbestos and lead sampling• Meets NIOSH 7400, 7082, 7105
and 7300 specifications• Full one-year warranty
Gilian AirCon-2Gilian AirCon-2
• Constant flow: 2-30 LPM • DC or AC Powered• Fully programmable for custom and
unattended sampling• Touchpad & LCD display• Instant fault function• Instant pressure check• Charges battery while in AC
operation
Key MarketsKey Markets
• Refineries• Chemical plants• Utilities• Construction sites• Foundries• Lead & asbestos abatement
High Flow vs. Low FlowHigh Flow vs. Low Flow
High Flow
• Personal Pump High Flow• Flow rates from 1 to 4 LPM• Examples:
– Lead– Asbestos– Dust
• Accessories– Filters– Cyclones– Impingers
Low Flow
• Flow Rates from 20 to 300cc/min
• Examples:– Hydrocarbon Solvents
(Benzene) – Chlorinated Solvents
(Methylene Chloride)– Alcohols
• Accessories• Sorbent Tubes • Charcoal Tubes
Constant Flow ControlConstant Flow Control
• Works like the cruise control on a car
• Senses when the flow rate is trying to drop and speeds up the pump
• Maintains the flow rate at ± 5% of set flow
Multiflow Low Flow PumpsMultiflow Low Flow Pumps
• Constant pressure control allows two to four simultaneous samples using special manifolds
• A constant low pressure level is maintained in the connection tubing
• Flow rate is controlled with a needle valve on each tube holder
Cyclone SamplersImpingersCharcoal Tubes
Filter Cassettes
Air Sampling AccessoriesAir Sampling Accessories
Filter Cassettes
Sorbent TubesSorbent Tubes
Universal Tube Holder SystemUniversal Tube Holder System
Air Sampling GuideAir Sampling Guide
Configuration GuideConfiguration Guide
Gilian Gilibrator-2Gilian Gilibrator-2
• True Primary Standard • NIST traceable • Easy Set-Up and Operation • Microprocessor Controlled • Field Portable • Low Maintenance • Alphanumeric Display • Built-in RS-232 Port • Auto Averaging of readings • Battery or AC operation
Gilian ChallengerGilian Challenger
• NIST traceable• Precise air flow calibration from
1-30 LPM• Wide temperature range of
-30° to +55° C• Displays both actual and
standard flow rates• Simple operation with no moving
parts• Truly portable, battery powered
calibrator
Pump Calibration SetupPump Calibration Setup
Understanding BackpressureUnderstanding Backpressure
Meet the Gilian FamilyMeet the Gilian Family
Pump SpecificationsPump Specifications
Gilian Pump MarketsGilian Pump Markets
• Construction companies for asbestos & lead abatement (BDX-II) and silica dust (Gilian 5000 with cyclone)
• Chemical plants, refineries, pharmaceutical plants, steel mills, utilities and many manufacturing plants (Gilian 5000)
• Dust sampling in foundries, cement plants, smelters, strip mines (Gilian 3500)
Petroleum RefineriesPetroleum Refineries
Top Sampling Issues: • Benzene or BTEX (NIOSH Method 1501)• Methyl tert-Butyl Ether (MTBE)
(NIOSH Method 1615)• Nickel Carbonyl (NIOSH Method 6007)• Tetraethyl Lead (NIOSH Method 2533)• Polynuclear Aromatic Hydrocarbon Compounds (NIOSH
Method 5506)
Power PlantsPower Plants
Top Sampling Issues: • Nuisance Dust (NIOSH Methods 0500 (Total dust) and
0600 (Respirable dust with cyclone)• Radioactive Dust (NRC Method uses Aircon at 28.32
LPM (1CFM) and 47mm PVC or glass fiber filter.)
Welding FumeWelding Fume
Top Sampling Issues:• (Note that all of these metals are sampled the same way using a
0.8 micron mixed cellulose filter at typically 1 to 4 LPM)
• Welding & Brazing Fume (NIOSH Method 7200) detects the following metals from one air sample. Iron, nickel, chromium, copper, cadmium, manganese, zinc and silver. Can be applied to soft steel or stainless steel welding.
• Chromium (NIOSH Method 7024 or 7300) Source: Welding of stainless steel.
• Cadmium (NIOSH Method 7038 or 7300) Source: Welding of plated metals & certain alloys.
• Manganese (NIOSH Method 7300) Source: Welding of most steels.
• Nickel (NIOSH Method 7300)Source: Welding of stainless steel.
Gas Detector TubesGas Detector TubesLow-cost Detection of Hazardous Gases & Vapors
DETECTOR TUBESDETECTOR TUBES
• Detector Tube Product Line - Manufactured by Kitagawa in Japan.
• Disposable glass tubes used to identify a targeted gas with in a specified measuring range when fixed amount of air is pumped through it.
– Simple
– Inexpensive
– Easy to use
– ± 25% Accuracy
Why Use SensidyneWhy Use Sensidyne
• Outstanding customer service.
• Finest technical support in industry.
• Excellent on time delivery record.
• Full line quality product.
• Refrigerated storage for longer shelf life.
• Shatter proof tubes.
Model AP-20SModel AP-20S
• Single-stroke operation• Ergonomically designed • Lightweight and corrosion-resistant• Piston-type volumetric pump assures accuracy every
time• Fail-safe handle locks in two positions (50 ml or 100 ml)• Flow finish indicator.
Sealed End
Sealed Tube
Gas Flow ArrowPre-Cleanse
Layer
Plug Plug
Analyzer Layer
Detector TubeDetector Tube
Taking A SampleTaking A Sample
Taking A Sample ContinuedTaking A Sample Continued
System SpecificationsSystem Specifications
• Accuracy: ± 25% of Reading
• Temperature: 0 to 40°C (32 to 104°F)
• Humidity: 10 to 90% RH
• Shelf Life: Two Years (Most Tubes)
Field Leak CheckField Leak Check
Field Leak Check ContinuedField Leak Check Continued
Inter-Brand CompatibilityInter-Brand Compatibility
• In general, mixing brand components is not recommended
• Some combinations can cause significant accuracy loss• Some brands are made to higher quality standards than
others• Sensidyne offers a Pump Swap for pumps from
competitors
Pump Swap ProgramPump Swap Program
Tube Selection GuideTube Selection Guide
Tube Selection GuideTube Selection Guide
Deluxe HazMat KitDeluxe HazMat Kit
Tube NO. 131 COLOR CHARTTube NO. 131 COLOR CHART
Tube NO. 186B Color ChartTube NO. 186B Color Chart
Manual Fit Test Part No. 5100RespiFit™ Fit Test No. 7013304-1
Smoke TubesSmoke Tubes
www.Sensidyne.comwww.Sensidyne.com 800-451-9444 / 727-530-3602