18
Giannis Combe Danilo Delgado Sara Patino TEST RIG FOR TEMPERATURE AND PRESSURE SENSORS FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Embed Size (px)

Citation preview

Page 1: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Giannis CombeDanilo

DelgadoSara Patino

TEST RIG FOR TEMPERATURE AND

PRESSURE SENSORS

FIU DEPARTMENT OF MECHANICAL ENGINEERINGMiami, FL

Page 2: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

OutlineProblem Statement

Project Description MotivationObjectives

Literature SurveyGlobal LearningSurvey of Related StandardsAlternative DesignsGantt Chart & Subdivision of ResponsibilitiesConclusion and Future Work

Page 3: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Problem Statement Design test fixture for sensor applications

corresponding to temperature and pressure Validate results

Page 4: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Motivation Provide HeartWare validity for their sensors

to be used in the medical field Provide a design that could be used by other

companies Ensure accuracy in closed-loop sensor

systems

Page 5: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Design Test Rig for Sensor of cylindrical shape Diameter: 7mm Length: 2mm

Collect experimental data at different: Pressures Temperatures

Create calibration table for air and liquid mediums Pressure range: -10 to 200mm Hg Temperature range: 20 to 60 ◦C

Support results with computational calculations Cost Analysis

Objective

Page 6: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Temperature Measurement• Thermocouple

• Resistance Temperature Detector

• DAQ

Results

Page 7: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

• Temperature Sensors• MEMS Sensors• Sensor Calibration • Resistance Temperature Sensors

Sensors

Page 8: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Pressure Measurement• Potentiometric

• Resonant Wire

Results

Page 9: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Survey of Related Standards "Selection and Characterizing Weathering

Reference Materials“ ASTM G156, 2009• Weathering piece of reference material • Procedure taken inside Laboratory

“Test Method for Temperature Calibration of Dynamic Mechanical” ASTM E1867, 2013

• Temperature Calibration of Dynamic Analyzers from 150 deg. To 300 deg. Celsius

“Reporting Uncertainty of Test Results and Use of term Measurement Uncertainty” ASTM E2655, 2014• Importance of Uncertainty in Quantitative Results• Methods of expressing Test Result Uncertainty

Page 10: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Global Learning Material Compatibility in Multinational levelso Languages

Dimensions and Specifications to be converted to international measurement systems

o SI/ English Units

Environmental Aspects o Hazardous Wasteo Assurance of No Leakage o Equipment Materials

Page 11: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Gantt ChartTask Jan Feb Mar Apr May Jun Jul Aug Sept Oct Nov Dec

Selection of Project                       

Problem definition                       

Consideration of

Alterative Designs

                     

Selection of final design                       

Manufacturing of Design                       

Testing                        

Production Calibration Table                        

Simulation                       

Evaluation                       

Final report                       

Page 12: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Subdivision of Responsibilities

Task Sara Patino Giannis Combe Danilo Delgado

Problem Definition      

Time Management      

Alternative Designs      

Manufacturing      

Testing      

Solidworks Simulation      

MatLab Simulation      

Cost Analysis      

Calibration Table      

Page 13: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Alternative Designs

Page 14: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Alternative #1

• Dual Sensing Elements

• Sensor Sheath • Transmitter

Page 15: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Pressure Testing: Hydrostatic testing

Heartware Sensor Pressure Gauge

[4]

Alternative #2

Page 16: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Alternative #3

• Water circulation system• Variable pressure/ temperature

testing• Self-adjusting

Page 17: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Conclusion and Future WorkExperimental analysis for optimization of best

designManufacturing of Test RigGeneration of calibration table for temperature

and pressure rangesMatLab SimulationSolidworks Simulation

o Thermal Analysiso Static Analysiso Flow Analysis

Page 18: Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL

Pressure and Temperature Sensor

Test Fixture

Giannis Combe

Sara Patino

Danilo Delgado

Problem Statement Design a test fixture to

calibrate sensors using a closed-loop system with input variables

Motivation Heartware will utilize the test

fixture in various sensor applications

The closed-loop system allows for pressure and temperature values to be entered and outputs reveal conclusions

Design Parameters Work with sensor of

Cylindrical shape with 2mm height and 7mm diameter

Must test efficiently under air and liquid mediums

Advisor: Nathalie Nunez

Design Objectives Create a test fixture for

pressure and temperature sensor applications

Develop a calibration table for a pressure range of -10mm Hg to 200mm Hg and temperature range of 20˚C to 40˚C

Perform simulation and computational analysis of test fixture functionality

Advisor: Dr. Sabri Tosunoglu